Clean Air Box Usage & Care
CABs
RAMs
COMonitors
ALLSAFE MARKETING SDN.BHD
ALLSAFE MARKETING SDN.BHDwww.allsafe.com.my
7/31/2019 Cab Usage and Care Allsafe
http://slidepdf.com/reader/full/cab-usage-and-care-allsafe 2/17
CAB Usage & Care
CAB Set Up
Calibration
Operation
Remote Alarm Shut Down
Monitor Battery Replacement
CO Sensor Replacement Filters & Drains
AA Battery Backup
ALLSAFE MARKETING SDN.BHD
7/31/2019 Cab Usage and Care Allsafe
http://slidepdf.com/reader/full/cab-usage-and-care-allsafe 3/17
CAB Set Up (Steps 1-3)(1) Attach
toIncomingAir Source(Do notexceed150 psi)
(2a) Connectto AC Power
Source
(Fixed Panels
may be hardwired)
(2b) Unit maybe operated on
(8) AAbatteries if no
AC powersource isavailable
(3) Flip ControlBox Switch toOn Position
ALLSAFE MARKETING SDN.BHD
7/31/2019 Cab Usage and Care Allsafe
http://slidepdf.com/reader/full/cab-usage-and-care-allsafe 4/17
CAB Set Up (Steps 4-6)
(4) Removethe CO Monitor
cover andpress the On
Button
(5) Wait for 60secondcountdown /
boot up
(6) If unit hasbeen recentlycalibrated thenset monitor to
Run mode,otherwiseproceed to
calibrationstepsALLSAFE MARKETING SDN.BHD
7/31/2019 Cab Usage and Care Allsafe
http://slidepdf.com/reader/full/cab-usage-and-care-allsafe 5/17
Zero Point Calibration (Steps 1-5)
(1) Zero withimpurity free
test gas
(3) AC will
appear on LCDscreen
(2) With coveroff and Monitor
On, rotateknob to Cal
position
(4) Press andhold On/Off button untilbeep sounds
(5) AO willappear on LCD
screen
ALLSAFE MARKETING SDN.BHD
7/31/2019 Cab Usage and Care Allsafe
http://slidepdf.com/reader/full/cab-usage-and-care-allsafe 6/17
Zero Point Calibration (Steps 6-12)
(6) Attachregulator tothe zero gas
cylinder
(7) Insert
calibrationconnector
fitting into thecenter hole of the CO Monitor
knob
(8) Open thecylinder valve
fully
(9) The Red LED willblink forapproximately 90seconds while the
zero process iscompleted
(10) Green LED willblink to indicate
successful zero pointcalibration
(11) Close the gascylinder and removethe connector fitting
from the monitor
(12) Rotate COMonitor knob to Run
ALLSAFE MARKETING SDN.BHD
7/31/2019 Cab Usage and Care Allsafe
http://slidepdf.com/reader/full/cab-usage-and-care-allsafe 7/17
Calibration (Steps 1-3)
(1) Select 5ppm or 10 ppm
test gas
(3) AC willappear on LCD
screen
(2) With Coveroff and Monitor
On, rotateknob to Cal
position
ALLSAFE MARKETING SDN.BHD
7/31/2019 Cab Usage and Care Allsafe
http://slidepdf.com/reader/full/cab-usage-and-care-allsafe 8/17
Zero Point Calibration (Steps 4-10)
(4) Attachregulator tothe test gas
cylinder
(5) Insert
calibrationconnector
fitting into thecenter hole of
the CO monitorknob
(6) Open thecylinder valve
fully
(7) The Red LED willblink for
approximately 90seconds while thecalibration process
is completed
(8) Green LED willblink to indicate
successfulcalibration
(9) Close the gascylinder and removethe connector fitting
from the monitor
(10) Rotate COMonitor knob to Run
ALLSAFE MARKETING SDN.BHD
7/31/2019 Cab Usage and Care Allsafe
http://slidepdf.com/reader/full/cab-usage-and-care-allsafe 9/17
Remote AlarmThe Remote Alarm duplicates the alarm
functions on the CAB unit to signal workersin a remote location that there is an alarm
condition with the system.
Connect the CAB unit to the Remote Alarmusing the provided cable.
Test by turning the air supply off (with COMonitor On and in Run position).
The low flow (LF) status will show on themonitor LCD and the visual and audible
alarms will activate.
Turning the air supply back on willdeactivate the alarm condition
ALLSAFE MARKETING SDN.BHD
7/31/2019 Cab Usage and Care Allsafe
http://slidepdf.com/reader/full/cab-usage-and-care-allsafe 10/17
CAB Shutdown (Steps 1-3)
(2) Shut off the incomingair to the CAB
unit
(3) Release air
pressure to thebox by pullingout the relief
valve ring
(1) Make sureall personnelhave left thework area
ALLSAFE MARKETING SDN.BHD
7/31/2019 Cab Usage and Care Allsafe
http://slidepdf.com/reader/full/cab-usage-and-care-allsafe 11/17
CAB Shutdown (Steps 4-5)
(4) Turn off theCO Monitor by
holding theon/off buttonfor 3 seconds
(5) You willhear 3 short
beeps toindicate the CO
Monitor isshutting off
ALLSAFE MARKETING SDN.BHD
7/31/2019 Cab Usage and Care Allsafe
http://slidepdf.com/reader/full/cab-usage-and-care-allsafe 12/17
CAB Shutdown (Steps 6-8)
(6) Turn thecontrol box
switch to theoff position
(7) Disconnectthe air supply
hoses
(8) Install dustcaps over theoutlet fittings
ALLSAFE MARKETING SDN.BHD
7/31/2019 Cab Usage and Care Allsafe
http://slidepdf.com/reader/full/cab-usage-and-care-allsafe 13/17
CO Monitor Battery ReplacementIf the 9V battery is being used to powerthe monitor and the battery power gets
low the LCD will display LB indicating thebattery needs to be changed.
(1) Removethe CO monitor
cover
(2) Removethe 9V battery
(3) Install new9V battery
ALLSAFE MARKETING SDN.BHD
7/31/2019 Cab Usage and Care Allsafe
http://slidepdf.com/reader/full/cab-usage-and-care-allsafe 14/17
CO Monitor Sensor Replacement
(1) Removethe 4 screws
on the front of the CO monitor
(2) Gently pry
off the coverfrom thebottom of the
housing
(3) Gently pull
on the oldsensor
(4) Removethe shortingclip from the
new sensor
(5) Align pins andgently push the new
sensor into the sockets
(6) Replace the frontcover of the monitor
when sensorreplacement is
complete. Ensure LEDsare aligned with
housing before securingfront cover with screws.
(7) Allow instrument towarm up at least 30minutes. Zero andCalibrate before the
next use.
ALLSAFE MARKETING SDN.BHD
7/31/2019 Cab Usage and Care Allsafe
http://slidepdf.com/reader/full/cab-usage-and-care-allsafe 15/17
Filter Usage & Care
Filter Housings /Bowls
Periodically removethe auto drains andclean with a mild
soapy solution. Re-
install into the filterhousing.
Auto Drains
They are installedon the 1st and 2nd
stages only andautomatically
drain bulk liquid
contaminants afterthe level has reach
1/3 of the bowlcapacity. Cleanperiodically withmild soap and
water. Make surethe tubing issecurely placed inthe holes at the
bottom of the unit.
Filter ChangeIndicators
The change indicatorswill gradually changefrom green to orange
when filter life isspent. Air must beflowing through theCAB unit before the
indicators will
function.ALLSAFE MARKETING SDN.BHD
7/31/2019 Cab Usage and Care Allsafe
http://slidepdf.com/reader/full/cab-usage-and-care-allsafe 16/17
AA Battery Back Up
Optional DC PowerSupply
CAB units may beoperated using (8)
AA batteries toprovide power to the
external lights, COalarm and the CO
monitor.
The AA batterycompartment islocated on the
interior surface of the CAB Box.
When operating onDC power the
amber light on thetop of the CAB unitwill burn steadily.
If the battery
power for the CABunit falls below therequired voltagethen the amber
light will begin toflash and an
audible alert in theform of shortintermittent beepswill notify the user
it is time tochange thebatteries.
ALLSAFE MARKETING SDN.BHD
7/31/2019 Cab Usage and Care Allsafe
http://slidepdf.com/reader/full/cab-usage-and-care-allsafe 17/17
Support