mkelectric.co.uk 632 CABLE MANAGEMENT PERIMETER AND DISTRIBUTION TECHNICAL SPECIFICATION ELECTRICAL VOLTAGE RATING 63A, 250V a.c. VOLTAGE DROP L to N = 3.47 mV/A/metre run L to E = 3.47 mV/A/metre run N to E = 3.47 mV/A/metre run EARTH FAULT LOOP IMPEDANCE L to E = 3.47 mΩ/m run. CONDITIONAL SHORT CIRCUIT RATING (Fuse links BS 88 – 100A and BS 1361 100A). Prospective current 16.5 KA Mechanical withstand 10.0 KA peak min MATERIALS PVCu materials used in the manufacture of MK products are self extinguishing non-flame propagating in accordance with BS 4678 Part 4 Extrusion material has been tested by a UKAS accredited laboratory in accordance with the requirements of BS476: part 7 and has achieved a Class 1Y Moulding material has been tested by a UKAS accredited laboratory and conforms with IEC 695-2-1 at a severity of 650°C IET WIRING REGULATIONS Designed and manufactured to comply in all respects with BS 7671:2008 (IET Wiring Regulations 17th Edition: 2008) QUALITY ASSURANCE The system is manufactured to BS EN ISO 9001 Tested to BS EN 61534-1:2011 & BS EN 61534-21:2006 For a full range of corresponding products, see pages 321-331 in the product selector. Powerlink Plus Technical Skirting and Dado Trunking System Description Powerlink Plus is a trunking distribution system which contains within its profile a 63A single phase set of busbars and facilities for carrying telecommunications and data services cables. Co-ordinated within the system is a wide variety of electrical and extra low voltage (ELV) outlets. On the mains side these include specially designed sockets, both switched and unswitched, nonstandard switchsockets, switches, connection units and, via a simple interface, facilities for mounting all standard MK outlets. ELV outlets include a master telephone socket outlet, an isolated co-axial socket outlet, “handset” telephone linejack outlet, computer sockets, a blank box and cover to accommodate other ELV requirements and, via a simple interface, facilities for mounting all single gang, standard MK ELV outlets. Also available are BNC type, LJU6C/RJ45 outlets, Euro Outlets and a blank to accommodate other ELV requirements. Incorporates a ‘Stay-set’ mechanism and is mains failure proof, ie it will function under all the normal conditions expected of an RCD and will not trip in the event of a power cut. This makes it suitable for use with freezers or in inaccessible or unmanned locations. FEATURES l Wide variety of visually and physically compatible mains and ELV outlets l Complete segregation between mains and ELV l Stylish and elegant appearance l Easy to assemble, extend and modify l Durable and impact resistant l Attractive styling l Suitable for skirting or dado mounting l 3 compartment trunking l Manufactured to high precision standards l All extrusions manufactured from 100% recycled material* *Based on 2014 consumption

Upload: others

Post on 18-Apr-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CABLE MANAEMENT PERIMETER AND DISTRIBUTION Powerlink … MK... · CABLE MANAEMENT PERIMETER AND DISTRIBUTION WALL THICKNESS Trunking base 2.4mm Centre compartment cover 2.5mm Curved

mkelectric.co.uk

632

CA

BLE

MA

NA

GE

ME

NT

PERI

MET

ER A

ND

DIST

RIBU

TION

TECHNICAL SPECIFICATION

ELECTRICAL

VOLTAGE RATING63A, 250V a.c.

VOLTAGE DROPL to N = 3.47 mV/A/metre run L to E = 3.47 mV/A/metre run N to E = 3.47 mV/A/metre run

EARTH FAULT LOOP IMPEDANCEL to E = 3.47 mΩ/m run.

CONDITIONAL SHORT CIRCUIT RATING(Fuse links BS 88 – 100A and BS 1361 100A). Prospective current 16.5 KA Mechanical withstand 10.0 KA peak min

MATERIALSPVCu materials used in the manufacture of MK products are self extinguishing non-flame propagating in accordance with BS 4678 Part 4

Extrusion material has been tested by a UKAS accredited laboratory in accordance with the requirements of BS476: part 7 and has achieved a Class 1Y

Moulding material has been tested by a UKAS accredited laboratory and conforms with IEC 695-2-1 at a severity of 650°C

IET WIRING REGULATIONSDesigned and manufactured to comply in all respects with BS 7671:2008 (IET Wiring Regulations 17th Edition: 2008)

QUALITY ASSURANCEThe system is manufactured to BS EN ISO 9001

Tested to BS EN 61534-1:2011 & BS EN 61534-21:2006

For a full range of corresponding products,

see pages 321-331 in the product selector.

Powerlink PlusTechnicalSkirting and Dado Trunking System

DescriptionPowerlink Plus is a trunking distribution system which contains within its profile a 63A single phase set of busbars and facilities for carrying telecommunications and data services cables.

Co-ordinated within the system is a wide variety of electrical and extra low voltage (ELV) outlets.

On the mains side these include specially designed sockets, both switched and unswitched, nonstandard switchsockets, switches, connection units and, via a simple interface, facilities for mounting all standard MK outlets.

ELV outlets include a master telephone socket outlet, an isolated co-axial socket outlet, “handset” telephone linejack outlet, computer sockets, a blank box and cover to accommodate other ELV requirements and, via a simple interface, facilities for mounting all single gang, standard MK ELV outlets. Also available are BNC type, LJU6C/RJ45 outlets, Euro Outlets and a blank to accommodate other ELV requirements. Incorporates a ‘Stay-set’ mechanism and is mains failure proof, ie it will function under all the normal conditions expected of an RCD and will not trip in the event of a power cut. This makes it suitable for use with freezers or in inaccessible or unmanned locations.

FEATURES

l Wide variety of visually and physically compatible mains and ELV outlets

l Complete segregation between mains and ELVl Stylish and elegant appearancel Easy to assemble, extend and modifyl Durable and impact resistantl Attractive stylingl Suitable for skirting or dado mountingl 3 compartment trunkingl Manufactured to high precision standardsl All extrusions manufactured from 100%

recycled material*

*Based on 2014 consumption

Page 2: CABLE MANAEMENT PERIMETER AND DISTRIBUTION Powerlink … MK... · CABLE MANAEMENT PERIMETER AND DISTRIBUTION WALL THICKNESS Trunking base 2.4mm Centre compartment cover 2.5mm Curved

Technical Hotline +44 (0)1268 563720

633

CA

BLE

MA

NA

GE

ME

NT

PERIMETER AND

DISTRIBUTION

WALL THICKNESS

Trunking base 2.4mm

Centre compartment cover 2.5mm

Curved cover 1.5mm

WEIGHT (KG)

TYPE

NUMBER OF COMPARTMENTSWITH SCREENING

1 2

Dado trunking without busbar (K1903)

2.4 3.0 3.6

Dado trunking with busbar (K1963)

3.0 3.6 4.2

POWERLINK PLUS CABLE CAPACITY

TYPE OF CONDUCTOR SIZE CABLE

FACTOR

COMPARTMENT 1(CURVED)

COMPARTMENT 2(WITH BUSBAR)

COMPARTMENT 2(WITH BUSBAR)

COMPARTMENT 3(SQUARE)

Full Term CSA 100% Fill (MM2)

943 2968 2528 1044

TERM AT 45% FILL (MM2)

424 1335 1137 469

POWER CABLES NUMBER OF CABLES AT 45% FILL

PVCstranded

1.5mm2 8.6 49 155 132 54

2.5mm2 12.6 33 105 90 37

4mm2 16.6 25 80 68 28

6mm2 21.2 20 62 53 22

DATA CABLESNUMBER OF CABLES AT 45% FILL (A) AND FULL CAPACITY (B)

A B A B A B A B

Cat 5E UTP 5.5mm dia. 30.2 14 31 44 98 0 0 15 34

Cat 6 UTP 6.5mm dia. 42.2 10 22 31 70 0 0 11 24

Cat 6 STP 7.0mm dia. 49.0 8 19 27 60 0 0 9 21

Powerlink Plus Technical

Dimensions (mm)The dado trunking is divided into three compartments. Two identical outer compartments are mainly for ELV cables with a third central compartment containing the busbars with a cableway above.

50

170

1

1

2

50

170

1

3

2

CROSS SECTION THROUGH DADO TRUNKING

CROSS SECTION THROUGH SKIRTING AND DADO TRUNKING

Skirting and Dado Trunking System

Page 3: CABLE MANAEMENT PERIMETER AND DISTRIBUTION Powerlink … MK... · CABLE MANAEMENT PERIMETER AND DISTRIBUTION WALL THICKNESS Trunking base 2.4mm Centre compartment cover 2.5mm Curved

mkelectric.co.uk

634

CA

BLE

MA

NA

GE

ME

NT

PERI

MET

ER A

ND

DIST

RIBU

TION

DIMENSIONS (MM)

FLAT ANGLE A B

DADO 270 170

SKIRTING 270 170

DIMENSIONS (MM)

FLAT TEE A B

DADO 270 170

Powerlink PlusTechnical

A

A

B

B

C

B

A

D

Flat Angles and TeesThese components are fabricated sections and space must be allowed for their inclusion in runs of trunking. All other components snap on over standard trunking profiles.

ComponentsThese components are fabricated sections and space must be allowed for their inclusion in runs of trunking. All other components snap on over standard trunking profiles.

Skirting and Dado Trunking System

K1903 (DADO TRUNKING

WITHOUT BUSBARS)

Page 4: CABLE MANAEMENT PERIMETER AND DISTRIBUTION Powerlink … MK... · CABLE MANAEMENT PERIMETER AND DISTRIBUTION WALL THICKNESS Trunking base 2.4mm Centre compartment cover 2.5mm Curved

Technical Hotline +44 (0)1268 563720

635

CA

BLE

MA

NA

GE

ME

NT

PERIMETER AND

DISTRIBUTION

TRUNKING END CAP

K1963 K1904

K1903 K1904

K1962 K1944

CABLE LINK ASSEMBLY

1919

TRUNKINGFLAT

ANGLE UP

FLAT ANGLE DOWN

K1963 K1992 K1992

K1903 K1992 K1992

K1962 K1957 K1958

CABLE TERMINATION

10mm2 1923WHI

25mm2 1924WHI

TRUNKINGEXT

CORNER

K1963 K1906

K1903 K1906

K1962 K1912

TRUNKINGINT

CORNER

K1963 K1905

K1903 K1905

K1962 K1911

PLUG IN BUSBAR COUPLER

K1925WHI

TRUNKING COUPLER

K1963 K1908

K1903 K1908

K1962 K1945

TRUNKING FLAT TEE UP FLAT TEE DOWN

K1963 K1992 K1992

K1903 K1992 K1992

Powerlink Plus Technical

Component Selection Guide

20mm*

15mm* to wall

13mm*

13mm*

13mm*

70mm*

130mm*

20

70

13

13

20

70

13

13

TRUNKING

K1963

K1903

20

70

13

13

20

70

13

13

* Minimum distance

Skirting and Dado Trunking System

Page 5: CABLE MANAEMENT PERIMETER AND DISTRIBUTION Powerlink … MK... · CABLE MANAEMENT PERIMETER AND DISTRIBUTION WALL THICKNESS Trunking base 2.4mm Centre compartment cover 2.5mm Curved

mkelectric.co.uk

636

CA

BLE

MA

NA

GE

ME

NT

PERI

MET

ER A

ND

DIST

RIBU

TION Powerlink Plus

Technical

GENERAL NOTES

Prior to installation strike a line of trunking using a plumb and chalk line for vertical, and spirit levels for horizontal runs.

Surface track accommodates 63 amp busbar with an integral duct directly above mains.

Data and Telecom cables.

Pre cut slots and circular holes at 100mm centres permit fi xing holes to be drilled and a wallplug with screw inserted after the surface track has been positioned.

When fi xing trunking use bushes provided and No. 8 wood screws.

Ensure trunking base is secured within 100mm from the end and a maximum of 500mm apart on either side along the length.

Check levels frequently – particularly at corners.

Debur all cut ends using a fi le or a sharp knife.

For mini trunking adaptors drill a 20mm diameter hole through the wall of the centre compartment using drill guide. Insert the tunnel and fi x with two screws provided.

Bridging busbar compartment – if required to take cables from top compartment to bottom or vice versa – drill holes to align with top and bottom holes of the centre compartment. Cut out 85mm from the busbar at the required position. Install cable link (1919) to the busbar and snap fi t cable crossing barrier (K1937CHA) over cables.

Commence installation at cable entry position. Route cables into the central section, wire in to the selected cable termination and plug into adjacent busbar and secure with screws supplied.

Installation Guide

1

2

4

3

8

7

9

10

1

2

3

4

5

6

8

Skirting and Dado Trunking System

5

6

Page 6: CABLE MANAEMENT PERIMETER AND DISTRIBUTION Powerlink … MK... · CABLE MANAEMENT PERIMETER AND DISTRIBUTION WALL THICKNESS Trunking base 2.4mm Centre compartment cover 2.5mm Curved

Technical Hotline +44 (0)1268 563720

637

CA

BLE

MA

NA

GE

ME

NT

PERIMETER AND

DISTRIBUTIONPowerlink Plus

Technical

7

9

10

Skirting and Dado Trunking System

Page 7: CABLE MANAEMENT PERIMETER AND DISTRIBUTION Powerlink … MK... · CABLE MANAEMENT PERIMETER AND DISTRIBUTION WALL THICKNESS Trunking base 2.4mm Centre compartment cover 2.5mm Curved

mkelectric.co.uk

638

CA

BLE

MA

NA

GE

ME

NT

PERI

MET

ER A

ND

DIST

RIBU

TION Powerlink Plus

Technical

Installation Guide Continued Cut central cover to length to fi t exactly between the exposed frontplates of accessories. At coupling positions leave expansion gaps by cutting the central cover to the same length as the trunking base.

Secure centre covers to the main base with the screws provided every 500mm max, top and bottom and within 150mm of accessories and fi ttings.

At the junction of two adjacent lengths of trunking busbar plug in the coupler to maintain electrical continuity. It is fi tted over a protector in the coupler carrier.

Data / Telecoms Devices – Secure enclosure box over centre compartment with screws supplied.

Run cabling into enclosure and terminate onto outlet on frontplate. Secure front cover to enclosure box with screws provided.

Internal and external corners – Connect the lengths of busbar using the cable link assembly (1919) and

secure trunking using the screws provided.

12

13

14

16

15

12

13

14

16

Skirting and Dado Trunking System

Page 8: CABLE MANAEMENT PERIMETER AND DISTRIBUTION Powerlink … MK... · CABLE MANAEMENT PERIMETER AND DISTRIBUTION WALL THICKNESS Trunking base 2.4mm Centre compartment cover 2.5mm Curved

Technical Hotline +44 (0)1268 563720

639

CA

BLE

MA

NA

GE

ME

NT

PERIMETER AND

DISTRIBUTIONPowerlink Plus

Technical

17 Moulded corner and coupler shields should be fi tted before fi tting any covers. They are secured by the central covers overlapping each side of the component and do not require additional fi xing.

Powerlink Plus Sockets – Plug the socket onto the busbars in the required region ensuring that the socket clips fully locate fi rmly on to their corresponding busbars. Secure with screws provided. Note – do not tamper with busbar clips.

Plug on connection units – Connect the load conductors which are either routed through the centre compartment of the trunking or enter through the fl ex outlet. Plug connection unit onto busbar where required and secure as described above.

Outer Covers – For central covers and end cap retainers, leave a gap of 8-10mm and snap fi t onto

trunking.

Snap fi t end caps then other trims after fi tting all central and outer covers.18

19

20

17

18

19

20

15

Skirting and Dado Trunking System