cah_bhme sell sheet
TRANSCRIPT
![Page 1: CAH_BHME Sell Sheet](https://reader038.vdocuments.net/reader038/viewer/2022100801/58996f0e1a28ab49478b521f/html5/thumbnails/1.jpg)
Keep the PEEP.
Advanced AirLife Bypass HME (BHME) technology helps
protect your patients with a closed system for continuous
ventilation, allowing you to deliver aerosolized medication
treatments without breaking the circuit.
1
lung derecruitment
Close the loop during medication delivery with advanced AirLife® BHME technology
Living, Breathing Innovation to Improve Ventilated Patient Outcomes
Deliver with ease.
One-handed operation allows easy bypass engagement,
Lever down
Gate open
Lever up
Gate closed
Aerosol mode HME mode
Bypass lever position and clear visual indicators ensure gate engagement
Aerosol mode HME mode
![Page 2: CAH_BHME Sell Sheet](https://reader038.vdocuments.net/reader038/viewer/2022100801/58996f0e1a28ab49478b521f/html5/thumbnails/2.jpg)
AirLife BHME Specifications
003020 AirLife Nonfiltered BHME
003021 AirLife Filtered BHME
Tidal Volumes 250 – 1250ml 250 – 1250ml
Weight 43g 44g
Dead Space 68ml 68ml
Moisture Loss2
250ml = 9.1mg H2O/L
500ml = 10.6mg H2O/L
750ml = 12.9mg H2O/L
1000ml = 14.3mg H2O/L
1250ml = 14.9mg H2O/L
250ml = 8.7mg H2O/L
500ml = 11.1mg H2O/L
750ml = 12.9mg H2O/L
1000ml = 14.7mg H2O/L
1250ml = 15.7mg H2O/L
Resistance Before Use2
Flow @ 0.5L/sec = 0.6cm H2O
Flow @ 1.0L/sec = 1.6cm H2O
Flow @ 1.5L/sec = 3.3cm H2O
Flow @ 0.5L/sec = 1.3cm H2O
Flow @ 1.0L/sec = 3.3cm H2O
Flow @ 1.5L/sec = 6.1cm H2O
Resistance After Use2
Flow @ 0.5L/sec = 0.7cm H2O
Flow @ 1.0L/sec = 2.0cm H2O
Flow @ 1.5L/sec = 4.5cm H2O
Flow @ 0.5L/sec = 1.5cm H2O
Flow @ 1.0L/sec = 4.0cm H2O
Flow @ 1.5L/sec = 6.0cm H2O
Filtration Efficiency3, 4, 5 N/ABFE = 99.999% VFE = 99.99%
Recommended Change-Out 24 hours 24 hours
Connections
15mm ISO male connector for “Y” piece 15/22mm ISO female/male connector for
ET tube, closed suctioning system, etc.
15mm ISO male connector for “Y” piece 15/22mm ISO female/male connector for
ET tube, closed suctioning system, etc.
Gas Leakage 0 cc/min at 7kPa (71cm H2O) 0 cc/min at 7kPa (71cm H
2O)
Compliance2 .68 ml/kPa at 7kPa (71cm H2O) .68 ml/kPa at 7kPa (71cm H
2O)
MR Conditional6
Field Strength = 3 – Tesla or less Spatial Gradient = 720 Gauss/cm or less
Radio Frequency (RF) Field = 128 MHz
Field Strength = 3 – Tesla or less Spatial Gradient = 720 Gauss/cm or less
Radio Frequency (RF) Field = 128 MHz
Packaging 25 units/case 25 units/case
2. Test results based on ISO-9360-1:2000 for both dry and wet conditions
4. BFE and VFE testing adapted from ASTM F2101
Reduce the risk.
The closed system helps minimize risks of VAP-related
infections.
Connect with the continuum.
The AirLife BHME connects you to a growing continuum
of solutions for your ventilated patient with convenient
single sourcing.
Optional filter helps prevent respiratory complications
and reduces chance of cross-contamination
© 2009 Cardinal Health, Inc. or one of its subsidiaries. All rights reserved.
AirLife is a registered trademark of Cardinal Health, Inc. or one of its subsidiaries.
Lit. No. 3RT2880
Cardinal Health
22745 Savi Ranch Pkwy.
Yorba Linda, CA 92887
www.cardinalhealth.com/respiratory