Page 1: CAH_BHME Sell Sheet

Keep the PEEP.

Advanced AirLife Bypass HME (BHME) technology helps

protect your patients with a closed system for continuous

ventilation, allowing you to deliver aerosolized medication

treatments without breaking the circuit.

1

lung derecruitment

Close the loop during medication delivery with advanced AirLife® BHME technology

Living, Breathing Innovation to Improve Ventilated Patient Outcomes

Deliver with ease.

One-handed operation allows easy bypass engagement,

Lever down

Gate open

Lever up

Gate closed

Aerosol mode HME mode

Bypass lever position and clear visual indicators ensure gate engagement

Aerosol mode HME mode

Page 2: CAH_BHME Sell Sheet

AirLife BHME Specifications

003020 AirLife Nonfiltered BHME

003021 AirLife Filtered BHME

Tidal Volumes 250 – 1250ml 250 – 1250ml

Weight 43g 44g

Dead Space 68ml 68ml

Moisture Loss2

250ml = 9.1mg H2O/L

500ml = 10.6mg H2O/L

750ml = 12.9mg H2O/L

1000ml = 14.3mg H2O/L

1250ml = 14.9mg H2O/L

250ml = 8.7mg H2O/L

500ml = 11.1mg H2O/L

750ml = 12.9mg H2O/L

1000ml = 14.7mg H2O/L

1250ml = 15.7mg H2O/L

Resistance Before Use2

Flow @ 0.5L/sec = 0.6cm H2O

Flow @ 1.0L/sec = 1.6cm H2O

Flow @ 1.5L/sec = 3.3cm H2O

Flow @ 0.5L/sec = 1.3cm H2O

Flow @ 1.0L/sec = 3.3cm H2O

Flow @ 1.5L/sec = 6.1cm H2O

Resistance After Use2

Flow @ 0.5L/sec = 0.7cm H2O

Flow @ 1.0L/sec = 2.0cm H2O

Flow @ 1.5L/sec = 4.5cm H2O

Flow @ 0.5L/sec = 1.5cm H2O

Flow @ 1.0L/sec = 4.0cm H2O

Flow @ 1.5L/sec = 6.0cm H2O

Filtration Efficiency3, 4, 5 N/ABFE = 99.999% VFE = 99.99%

Recommended Change-Out 24 hours 24 hours

Connections

15mm ISO male connector for “Y” piece 15/22mm ISO female/male connector for

ET tube, closed suctioning system, etc.

15mm ISO male connector for “Y” piece 15/22mm ISO female/male connector for

ET tube, closed suctioning system, etc.

Gas Leakage 0 cc/min at 7kPa (71cm H2O) 0 cc/min at 7kPa (71cm H

2O)

Compliance2 .68 ml/kPa at 7kPa (71cm H2O) .68 ml/kPa at 7kPa (71cm H

2O)

MR Conditional6

Field Strength = 3 – Tesla or less Spatial Gradient = 720 Gauss/cm or less

Radio Frequency (RF) Field = 128 MHz

Field Strength = 3 – Tesla or less Spatial Gradient = 720 Gauss/cm or less

Radio Frequency (RF) Field = 128 MHz

Packaging 25 units/case 25 units/case

2. Test results based on ISO-9360-1:2000 for both dry and wet conditions

4. BFE and VFE testing adapted from ASTM F2101

Reduce the risk.

The closed system helps minimize risks of VAP-related

infections.

Connect with the continuum.

The AirLife BHME connects you to a growing continuum

of solutions for your ventilated patient with convenient

single sourcing.

Optional filter helps prevent respiratory complications

and reduces chance of cross-contamination

© 2009 Cardinal Health, Inc. or one of its subsidiaries. All rights reserved.

AirLife is a registered trademark of Cardinal Health, Inc. or one of its subsidiaries.

Lit. No. 3RT2880

Cardinal Health

22745 Savi Ranch Pkwy.

Yorba Linda, CA 92887