callaway plant, unit 1, revision ol-23 to final safety

106
GUIDE THIMBLE 0 FUEL ASSEMBLY WITH ROD CONTROL CLUSTER 0 0 0 0 0 0 @ 0 e 0 0 _JL.oso TYP IFM GRIDS CONTROL CLUSTER ELEMENT FUEL ROD (264 PER FUEL ASSEMBLY) OD = .360 CLAD THICKNESS = .0225 CLAD MATERIAL = ZIRC-4/ZIRLO 0 11.973 FUEL ASSEMBLY AND RCCA PITCH 8.455 TYP INSTRUMENTATION TUBE FUEL ASSEMBLY WITHOUT ROD CLUSTER CONTROL A. GUIDE THIMBLE DIMENSIONS AT TOP NOZZLE .ADAPTOR PLATE CALLAWAY PLANT ARE IN INCHES (NOMINAL) FIGURE 4.2-1 FUEL ASSEMBLY CROSS SECTION 17 X 17 VANTAGE 5N+ REV. OL-9 5/97 SHEET 1

Upload: others

Post on 06-Feb-2022

0 views

Category:

Documents


0 download

TRANSCRIPT

GUIDE THIMBLE

0

FUEL ASSEMBLY WITH ROD CONTROL CLUSTER

0 0 0

0 0 0

@ 0 e

0 0

_JL.oso TYP IFM GRIDS

CONTROL CLUSTER ELEMENT

FUEL ROD (264 PER FUEL ASSEMBLY) OD = .360 CLAD THICKNESS = .0225 CLAD MATERIAL = ZIRC-4/ZIRLO

0

11.973 FUEL ASSEMBLY AND RCCA PITCH

8.455 TYP

INSTRUMENTATION TUBE

FUEL ASSEMBLY WITHOUT ROD CLUSTER CONTROL

A. GUIDE THIMBLE DIMENSIONS AT TOP NOZZLE .ADAPTOR PLATE

CALLAWAY PLANT

DI~ENSIONS ARE IN INCHES (NOMINAL) FIGURE 4.2-1

FUEL ASSEMBLY CROSS SECTION 17 X 17 VANTAGE 5N+

REV. OL-9 5/97

SHEET 1

C()fjTROL !304 SST)

..xu.Jl.. tl auaeot

8.386 TYP (UPDATED IFM)

8.372 TYP (IFM)

-11--1-+- .0~3 ( INCONEL) .053 (Z.IRC)

.0105 l>l~IDE STil.v>~ ("'coNE\) .o•So '"""oE STRAPS !ZIRC)

SEE VIEW A

0 0 0

.048 (INCC~aP

.035(ZIRC)

0 0

0 0

0 0

00

0000000 00000

ooo 00

0 00 0

0 0

0 0

00· .474 ID- .442

8.466 TYP

FUEL&CONTROL ROO CROSS SEC'!'ION MA TDIAL· ZIRC-4 OR ZIRLO

CALLAWAY PLANT

FIGURE 4.2-1

FUEL ASSEMBLY CROSS SECTION 17 X 17 VANTAGE 5N+

REV. OL-9 5/97

SHEET2

CALLAWAY - SP

Rev. OL-13 05/03

Figure 4.2-1A has been deleted.

7.162 TYP ll£F

0.!!7S , 'TYP ll£F

.578 • RET

BOTTOM VIEW (TYP)

I 159.975

, .. ~ 1- lr---1· ---152.25---

1-.4~5 A.l'oi1-J)

122.67 LJ, L . .t U50 L L L (GRIDS 2-7)

133.8.3 113.28 92.73 72.16 51.63 31.0!! 6.00 ~

17X17 VANTAGE 5 FUEL ASSEMBLY

!------------------- 15~.975 -----------------~

17X17 VANTAGE 5 UPDATE FUEL ASSEMBLY

(a) Gopm!uced&am 1.10incbcstoO.o46Sin<:bco.

DIMENSlONS AAE IN INCHES (NOMINAl..)

!51.27 30.72

CALLAWAY PLANT

REV. OL-7 5/94

FUEL ASSEMBLY OUTLINE

17x17 VANTAGE 5 FIGURE 4.2-2

CALLAWAY PLANT

FIGURE 4.2-2A

STANDARDIZED BOTTOM NOZZLE PICTURE OF 17 X 17 SDFBN

REV. 6 5/12

(. 621) ~ TYP

(3. 475)

cs.404l sa

(7. 162) TYP • -~1

• 875 DIA TYP \

·---~-- (0 . 580)

(159.975)

(152.490) FUEL ROD LENGTH

" "" m ...... 1

( 6. 750)

TYI

L~ ~ 875 O!A TYP ------ J

~ (5. 835)

CALLAWAY PLANT

17Xl7 VANTAGE+ FUEL ASSEMBLY

(ZIRLO) FIGURE 4. 2-28

. ~ - ~--~(2. 383)

REV OL-11 5/00

f---------- ( L.,2.8 F,EL LENC~TH) ---------4~---4--

CALLAWAY PLANT

FIGURE 4.2-2C

17X17 PERFORMANCE+ FUEL ASSEMBLY

REV. 14 5/12

CALLAWAY PLANT

FIGURE 4.2-20

WESTINGHOUSE INTEGRATED NOZZLE PICTURE OF WIN TOP

NOZZLE

REV. 0 2/09

152.285

FUEL ROD LENGTH

7.525

PLENUM

144.00

- FUEL STACK LENGTH

SEAL WELD

ZR-4 TOP END PWO (-J...l----1/

GIRTH WELD

• 3 6 0 NOMINAL (.368 MAX)

SPRING STAINLESS STEEL

U0 2 PELLET

PELLET -CLAD GAP

nr~:-'-jp, ___ ZIRCALOY CLAD

.0225 NOMINAL WALL THICKNESS (.0207 MINIMUM WALL)

1'------'t---- GIRTH WELD

~="" • >--1---- BOTIOM END PLUG ILLUSTRATES

-'-------------- ~:~ INTERNAL GRIP CONNECTION

17x17 VANTAGE 5 UPDATE FUEL ROD ASSEMBLY

SPECIFIC DIMENSIONS DEPEND ON DESIGN VARIABLE SUCH AS PREPRESSURIZATION, POWER HISTORY, AND DISCHARGE BURN UP (SEE ALSO FIGURES 4.2-38 AND 4.2-3C)

OIIAEHSIONS AAE IN INCHES (N01.41NAL)

CALLAWAY PLANT

REV. OL-13 05/03

FUEL ROD SCHEMATIC

FIGURE 4.2-3

. 3685 MAX WELD DIA.

TOP END PLUG

VARIABLE PITCH STAINLESS STEEL SPRING

ZIRLO TUGE (. 350) OD (. 0207) MIN WALL

URANIUM DIOXIDE PELLETS

ZR-4 BOTTOM END PLUG

. 3685 MAX WELD DIA.

1~----(7.730) -------1---------­ ( 144. 00) FUEL--------' COLUMN LENGTH

~-------------------(152.490)------------------1

REV OL-13 05/03

CALLAWAY PLANT

17Xl7 VANTAGE+ FUEL ROD

ZIRLO™ FIGURE 4. 2-3A

REV OL-13 05/03

CALLAWAY PLANT

17X17 PERFORMANCE+ FUEL ASSEMBLY

FIGURE 4.2-3B

GRID STRAP

" EXPANSION DIAMETER

ZIRCALOY OR ZIRLO SLEEVE

ZIRCALOY OR ZIRLO THI~1BLE

FUEL ROD

EXPANSION LOBE

IFM AND MID GRID EXPANSION JOINT DESIGN

REV. OL-9 5/97

CALLAWAY PLANT

PLAN VIEW

FIGURE 4.2-4

GUIDE THIMBLE TUBE -----n

IFM GRID ---1

EXPANSION LOBE --~

GUIDE THIMBLE TUBE-----+,

MID GRID

MID GRID SLEEVE ---+N

EXPANSION LOBE ---«t

DIMENSIONS ARE IN INCHES (NOMINAL)

WELD

WELD

MIXING VANE

.475

MIXING VANE

t

2 .. 250

!

CALLAWAY PLANT

REV. OL-5 6/91

GRID TO THIMBLE ATIACHMENT JOINTS

FIGURE 4.2-5

LOCK TUBE

UNASSEMBLED

SECTION E-E

(TYPICAL)

I

I I

I I

I D I

' I

--+--

ASSEMBLED

REV. OL-5 6/91

CALLAWAY PLANT

THIMBLE/INSERT /TOP GRID SLEEVE BULGE JOINT GEOMETRY

FIGURE 4.2-6

CALLAWAY PLANT

GUIDE THIMBLE TO BOTTOM NOZZLE JOINT

FIGURE 4.2-7

REV OL-13 05/03

CR04

RCC ASSEMLY INSERTED

DRIVE ROO ASSEMLY

Fll.L LfHG TH ACC ASSEMLY

WIDE TUBE ASSEMB..Y

FUEL ASSEMB.. Y

CALLAWAY PLANT

FIGURE 4.2-8

ROD CLUSTER

Rev. OL-0 6/86

CONTROL AND DRIVE ROD ASSEMBLY WITH INTERFACING COMPONENTS

160.949

I_ 1.845 MAX

SPIDER BODY

-

150.574

80% SILVER 15% INDIUM 5% CADMIUM

CALLAWAY PLANT

RCCA OUTLINE FULL -LENGTH

FIGURE 4. 2 - 9 .J

TOP END PLUG

TYPE 304 STAINLESS STEEL TUBE WITH CHROME PLATING Ag-ln-Cd

BOTTOM END PLUG

.381 DIA NOM

~--------- 142.00 -----------J

ABSORBER MATERIAL

151.885

REV. QL.,...5 6/91

CALLAWAY PLANT

ABSORBER ROD

FIGURE 4.2-10

l[] (() l[]

014-A-20766-163

I f-

"(0 LL.z ww a:_j

Oz ·o

N(f) "<!-,__. -o

Q_

(f) (0 z ...... a: Q_ (f)

(f) (f) Q(f) a:<x: Q_j (]](0

~~ o­r:n -otl.l NC) as: "<!-~ N<I:J "<!- ....... ·0

0

I

CALLAWAY PLANT

FIGURE 4.2-11 BURNABLE ABSORBER

ASSEMBLY 17X17

REV. OL-7 5/94

014-A-20766-164

0 lJl r0

N lJl

X <

lll:L ffi· 10< ..... 00

~ C) :) _j D..

0 z w

<

L I~

_j ~ ::;: 0 f-­f--0 !Il w

~ ......

u .... _j .... UJUJ OUJ 0::< O_j !I] C)

~I

C) :) _j D..

0

~ I D.. 0 f--

~r--.

C) z w _j

z 0 Ul .... 0 D..

u... w a: 0 0

N ~

_j

lll· I'll.. mw

·0:: 0

I f-­(9 z w _j

w !Il :) f--

u... w a: m 0

0 lJl

Ul Ul < _j C)

w f-­< u .... _j .... Ul 0 a: 0 !Il

_j w w f-­Ul

Ul Ul w _j z .... < f-­Ul

<1: I

<1:

z 0

1-u w (f)

CALLAWAY PLANT

FIGURE 4.2-12 BURNABLE ABSORBER ROD

CROSS SECTION 17X17

Rev. OL-1 6/87

150.0 TYPICAL

ANNULAR PLENUM

* 134.0 TYPICAL

ABSORBER LENGTH

r A

Note: See Figure 4.2-15A for new spring design.

* 132.0 inches in Current feed assemblies

014-A-20766-165

FLOW PATH

l 11...---UPPER END

PLUG

+ A

FLOW PATH

ZIRCALOY TUBES

A lz03-B4C ANNULAR PELLETS

SECTION A-A

CALLAWAY PLANT

ZIRCALOY

REV OL-13 05/03

FIGURE 4.2-12a BURNABLE ABSORBER ROD

CROSS-SECTION (ALUMINUM OXIDE BORON CARBIDE ABSORBER)

1 ~ ~ ~ ~ \®--a I I 1-.-:La: ow zu lf14:

0.. NUl t<)

:;i; 1---I I •;:::J I I :;:i;H

0~ zo I LOt>.! f-•H (!)

r-IH z ~ w u '--- ..J

I I I z I 0 I (f)

...... 0 0..

('f) LL... Lf) w . a: r-1 Lf) I I I N r-1 <t

I - I

I I I

I

-L-

I I I

I I

~ ~ I I I~ ~

YYY:

I -==-' e-c= .r::..

~~aa I I I I

I I I I

(f) w I u z ......

I I I z ......

I w a: 4:

(Jl z 0 H (Jl

I I I z w

I :L ...... 0

..J

..J <{

.. I I I w

f-0

I z

I I I

I

~ I I I

/L) I I

~~yy (f) (!) z ..... a: 0.. (Jl

,......__

"" ~

(f) (f) w ..J Z..J ...... w 4:W f-f­(f)(J)

:L :::) H

z a: 0 LL...

w ..JZ aJO <{(f) z,..... a:o :)D.. (I)

REV. OL-7 5/94

NOTE: See Figure 4.2-lSA CALLAVVAYPLANT for new spring design~------------~-------------------------1

014-A-20766-166

FIGURE4.2-13 PRIMARY SOURCE ASSEMBLY

17X17

NOTE: See Figure 4.2-15A for new spring design

014-A-20766-167

tL W::J u ..... O::_J ::J_j 0>-(flO:

0 w . >-aJ roo: (!)<(>-

oz zo OL u-WI-UlZ

l<(

(f) w I u z

z .... w 0::: <(

(f) !() z 0

0 !() (f) - z w

L .... 0

__) _j <(

-w 1-0 z

0 N

W I

...Jcn >­a:l;:~ 1-L...J ;::

~a_ ~ ::J 0

CALLAWAY PLANT

FIGURE 4.2-14 SECONDARY SOURCE ASSEMBLY

17X17

REV. OL-7 5/94

"Y" Corner Orientation

I. (0.426 Dia)

DOUSLE ENCAPSULATED SE::CONDAAY SD~CE ROD

I

THIMBLE PLUG

Spring lnconel 718

I~

11-: -----"'- 88.00 Antimony-Beryllium

l:l

1-----6.345 ---t

1-----------151.553-----------1

CALLAWAY PLANT

REV OL-11 5/00

FIGURE 4.2-14A ENCAPSULATED SECONDARY

SOURCE ASSEMBLY 17X17

0.432 (STD ONLY) 0 . 4 2 4 (OLD DESIGN) 0.426 (NEW DESIGN)

NOTE: See Figure 4.2-15A for new spring design

014-A-20766-168

7. 94 (OLD DESIGN) 6.345(NEW DESIGN)

CALLAWAY PLANT

FIGURE 4.2-15 THIMBLE PLUG ASSEMBLY

REV. OL-9 5/97

I I I

I I I : I !

I I

I' I I

i. I :.. w

Previous

17 X 17

Pinned & Welded Nuts

I I

i I

I I

I ! I I

! I u . !

New

Hold down Assembly Updates - 17 x 17

REV. OL-5 6/91

CALLAWAY PLANT

MODIFIED SPRING DESIGN

FIGURE 4.2-15A

goo

014-A-20766-169

R P N M L K J G F E 0 C B A

FIRST CORE

D REGION

~ REGION 2

~ REGION 3

CALLAWAY PLANT

FIGURE 4.3-1

2

3

4

5

--6

--7

--8 270°

--9

--10

--II

12

13

14-

15

Rev. Ol-1 6/87

FUEL LOADING ARRANGEMENT

9

8

::> 7 ~ -en ::.:::

(I) 6 UJ I:L 0 1-0

5 (I)

~---0::: UJ ;' :X: / (.!:)

~ :X: / Pu239 u...

/ 0

z:: 3 0

I 1-u ::>

I 0 0 2 0::: I:L

I

0

BURN UP

0

-~

-8 ~· -en ::.:::

-12 (I) UJ I:L 0 --- 1-0

-16 (I)

....J UJ ::>

-20 u... u... 0

z:: 0

-2~ -1-I:L ~ ::> (I)

z:: -28 0

u

-32

-36 ~0

CALLAWAY PLANT

FIGURE 4.3-2

Rev. Ol-0 6/86

PRODUCTION AND CONSUMPTION OF HIGHER ISOTOPES

2000 r-----------------------------------------------~

1600 l.._

................ ........

1200

800

400

NOTE: HOT, FULL POWER, RODS OUT

'-, JWITHOUT BURNABLE " ABSORBERS

........ ........

........ ........

........ ........

' ' ' ' ' ' 0 ~----~----~----~----~----~----~----~~--~~~

0

014-A-20766-170

4000 8000 12,000 16,000

CORE AVERAGE BURNUP (MWO/MTU)

CALLAWAY PLANT

FIGURE 4.3.3A

Rev. OL-1 6/87

BORON CONCENTRATION VERSUS FIRST CYCLE BU RNUP WITH AND WITHOUT

BURNABLE ABSORBER RODS

CALLAWAY - SP

Figure 4.3-3B Deleted.

Rev. OL-1 6/87

!XI !XI

!XI D !XI !XI

!XI D !XI !XI

DIXI !XI D D !XI

!XI D DIXI

014-A-20766-171

!XI !XI !XI !XI !XI D !XI !XI

!XI D r;R1 !XI D !XI D !XI

!XI !XI D !XI !XI D !XI D !XI !XI D !XI D !XI

!XI !XI !XI !XI !XI D !XI !XI

20 BA'S CORE CENTER

16 BA'S

D IXID !XI !XI [g1 IXID !XI D !XI !XI D !XI D D

!XI D !XI !XI D D !XI D !XI !XI D D D D

D IXID Do D Do

12 BA'S CORE CENTER

9 BA'S

!XI !XI

!XI D

!XI D

D D Do

t !XI !XI !XI

!XI D !XI

D !XI

D D D D oo

10 BA'S

CALLAWAY PLANT

FIGURE 4.3·4A

Rev. Ol·1 6/B7

BURNABLE ABSORBER ROD ARRANGEMENT WITHIN AN ASSEMBLY

CALLAWAY - SP

Figure 4.3-4B Deleted.

Rev. OL-1 6/87

180° R P N M L K J H G F E D C B A

I I I I I I I 10 10 10

9 12 20 19 12 9 IS

9 20 16 16 16 20 9

20 20 4S 16 16 20 20

12 20 16 16 16 20 12 --10 16 16 20 20 16 16 10 --

20 16 20 20 20 16 20 --10 16 16 20 20 16 16 10 --

20 16 20 20 20 16 20 --10 16 16 20 20 16 16 10 --

12 20 16 16 16 20 12 --

20 20 16 16 4S 20 20

9 20 16 16 16 20 9

9 12 20 19 12 9 IS

10 10 10

NUMBER INDICATES NUMBER OF BURNABLE ABSORBER RODS

IS INDICATES PRIMARY SOURCE ROD

4S INDICATES FOUR SECONDARY SOURCE RODS

2

3

4

5

6

7

8 270°

9

10

I I

12

13

14

15

REV OL-13 05/03

014-A-20766-172

CALLAWAY PLANT

FIGURE 4.3-5 A TYPICAL BURNABLE ABSORBER LOADING

PATTERN (CYCLE 1)

CALLAWAY - SP

Figure 4.3-SB Deleted.

Rev. OL-1 6/87

ct_l H G F E D C B A ct_ I

- I . 06 f--f- - --- -f--f- -f--f- -f--f- -f--f-

8~~ I I

9 I .00

I I 0 I. 12

I

I I

I I I. 15 I

I I

12 I .21 I

I I

13 I. 12 I

I I

14 I .03

I I

15 0. 72

0 14-A-20766-173

GDDDDDD GBDDDDD BBBDDDD BBBBDD BGGEJBD B 10.99110.991 EJ B BBEJ

CALCULATED F~H = I . 35

KEY: VALUE REPRESENTS ASSEMBLY RELATIVE POWER

CALLAWAY PLANT

FIGURE 4.3-6A

REVOL-13 05/03

TYPICAL NORMALIZED POWER DENSITY DISTRIBUTION NEAR BEGINNING-OF-LIFE,

UNRODDED CORE, HOT FULL POWER, NO XENON (CYCLE 1)

CALLAWAY - SP

Figure 4.3-6B Deleted.

Rev. 01-l 6/87

ct_ I H G F E 0 c B A ct_ I

- 1.09--8 I

--- -1--r-

I I

9 1.02

I I

I 0 I. 15 I

I I I I. 16

I 12 I .22

I I

13 I. 12

l 14 I .02

I I

15 0. 71

014-A-20766-174

BDDDDDD GBDDDDD BBBDDDD BBGDDD BGGBBD BBEJEJB EJE]EJ

CALCULATED F~H = I . 34

KEY: VALUE REPRESENTS ASSEMBLY RELATIVE POWER

CALLAWAY PLANT

FIGURE 4.3-7 A

REV OL-13 05/03

TYPICAL NORMALIZED POWER DENSITY DISTRIBUTION NEAR BEGINNING-OF-LIFE, UNRODDED CORE, HOT

FULL POWER, EQUILIBRIUM XENON (CYCLE 1)

CALLAWAY - SP

Figure 4.3-7B Deleted.

Rev .. OL-l 6/87

ct_ I H G F E 0 c B A ct_ I

- l.oo---8 I

-r---1- -r---1- -1-- --I I

9 1.00 I

I I

10 I. 15 I

I I

J J I. 18 I

I I

I 2 I .25 I

I I

I 3 I. 13 I

I 14 0.95

I

I 15 0.69

014-A-20766-175

GDDDDDD GGDDDDD GBBDDDD BGGGDD BBBBBD BGGEJB BBB

CALCULATED F~H I .33

KEY: VALUE REPRESENTS ASSEMBLY RELATIVE POWER

CALLAWAY PLANT

FIGURE 4.3-8 A

REV OL-13 05/03

TYPICAL NORMALIZED POWER DENSITY DISTRIBUTION NEAR BEGINNING-OF-LIFE, GROUP D AT 28 PERCENT INSERTED, HOT FULL POWER, EQUILIBRIUM XENON

(CYCLE 1)

CALLAWAY - SP

Figure 4.3-8B Deleted.

Rev. OL-1 6/87

~I H G F E 0 c B A

~ I

- 1.15-1- -f--r- -f--r- -- -- --8 I

I I

9 I. 18 I

I I

I 0 I. 15 I

I I

I I I .21 I

I I

12 I. 13 I

I I

13 I. 14 I

I

BDDDDDD BBDDDDD BGBDDDD BBBGDD GBGEJBD

14 0.97 G 10.94110.961 EJ B I

I 5 0. 70 I 0. 731 I 0. 651 I 0. 541

~ CALCULATED F~H = I . 29

014-A-20766-176

KEY: VALUE REPRESENTS ASSEMBLY RELATIVE POWER

CALLAWAY PLANT

FIGURE 4.3-9A

REV OL-13 05/03

TYPICAL NORMALIZED POWER DENSITY DISTRIBUTION NEAR MIDDLE-OF-LIFE, UNRODDED CORE, HOT FULL

POWER, EQUILIBRIUM XENON (CYCLE 1)

CALLAWAY - SP

Figure 4.3-9B Deleted.

Rev. OL-1 6/87

ct_ I H G F E D c B A ct_ I

-1.05--8 I

-1--~ -1--t- -1--~ -~~ --- ---

I I

9 I. II

I I

I 0 I .05

I I

I I I. 12

I I

12 I .06

I I

13 I. 13

l 14 I .01

_l

l I

15 0.80

014-A-20766-177

BDDDDDD BBDDDDD BBGDDDD BGBBDD BBBGBD BEJGBB EJBB

CALCULATED F~H = I . 25

KEY: VALUE REPRESENTS ASSEMBLY RELATIVE POWER

CALLAWAY PLANT

FIGURE 4.3-10A

REV OL-13 05/03

TYPICAL NORMALIZED POWER DENSITY DISTRIBUTION NEAR END-OF-LIFE, UNRODDED CORE, HOT FULL

POWER, EQUILIBRIUM XENON (CYCLE 1)

CALLAWAY - SP

Figure 4.3-lOB Deleted.

Rev. OL-1 6/87

ct_ I H G F E 0 c B A ct_ I

- 0.92f--~

8 I

-f--f- f--f- --- --- ---I I

9 I .08 I

I I

I 0 I .06 I

I I

I I I. 15 I

I I

12 I .09 I

I I

13 I. 17 I

I I

14 I .04 I

I I

15 0.82

0 14-A-20766-178

BDDDDDD BGDDDDD GBBDDDD BGBBDD BBBBEJD BBBBEJ EJBEJ

CALCULATED F~H = I . 25

KEY: VALUE REPRESENTS ASSEMBLY RELATIVE POWER

CALLAWAY PLANT

FIGURE 4.3-11 A

REV OL-13 05/03

TYPICAL NORMALIZED POWER DENSITY DISTRIBUTION NEAR END-OF-LIFE, GROUP D 28 PERCENT INSERTED,

HOT FULL POWER, EQUILIBRIUM XENON (CYCLE 1)

--- --------

CALLAWAY - SP

Figure 4.3-llB Deleted.

Rev. OL-1 6/87

r---

I. 02

1.02 I. 03

1.02 1.05 1.08

1.02 1.06 I. 12 ~ 1.03 I. 08 I. 14- I. 17 I. 16

1.03 I. 10 ~ I. 17 I. 18 X 1.03 1.08 I. 14- I. 14- I. 16 I. 18 I. 17

1.03 1.08 I. 14- 1. 14- 1. 16 I. 19 I. 17

1.03 I. 10 X I. 16 I. 18 X I. 19

1.03 1.09 I. 14- I. 14- I. 16 I. 19 I. 17

1.03 1.09 I. 15 I. 15 I. 16 I. 19 I. 17

I. 04- I. I I ~ I. 18 I. 18 X I. 19

I. 04- I. 09 I. 15 I. 18 I. 17 I. 19 I. 17

1.04- I. 08 I. 14- X I. 18 I. 18 I. 16

1.04- 1.06 I. 10 I. 14- I. 16 ~ I. 16

1.04- I. 05 1.07 1.08 I. 10 I. 12 1. 10

I. 04- I. 04- 1.04- I • 04- I. 05 I. 05 I. 05

I. 17

I. 20 >< I. 17 I. 20

I. 17 I. 20

I. 19 X I. 17 I. 19

I. 16 I. 18

I. 16 ~ I. 10 I. 12

I. 05 I. 05

I. 18

I. 18 I. 18

I. 20 I. 20 X I. 17 I. 17 I. 20 I. 18

I. 16 I. 16 I. 19 I. 19 ~ I. 16 I. 16 X I. 17 I. 15 I. I I

I. I 0 I. I I I. 12 I • I I I. 09 I. 08 1.07

I. 05 I. 05 I. 06 I. 06 1.06 1.06 I. 06

CALLAWAY PLANT

FIGURE 4.3-12

6274--6

1.06j

Rev. OL-0 6/86

RODWISE POWER DISTRIBUTION IN A TYPICAL ASSEMBLY NEAR BEGINNING­

OF-LIFE, HOT FULL POWER, EQUILIBRIUM XENON; UNRODDED CORE

-0.98

0.98 0.99

0.98 1.00 1.03

0.99 1.02 I. 07 X 1.00 1.03 1.09 I. II 1.09

1.0 I 1.06 C>< I. II I. II

1.00 1.0~ 1.08 1.07 1.08

1.00 1.0~ 1.08 1.07 I. 08

1.0 I 1.06 C>< 1.09 I. 10

1.00 1.0~ 1.08 1.07 1.08

1.00 1.0~ 1.08 1.07 I. 08

1.0 I 1.06 C>< I. II I. II

1.00 1.03 1.09 I. II 1.09

0.99 1.02 1.07 C>< I. II 0.98 1.00 1.03 1.07 1.09

0.98 0.99 1.00 1.02 1.03

0.98 0.98 0.98 0.99 1.00

C>< I. 10 I. 08

1.10 1.08 1.08

X I. 10 I. 10 ~ I. 10 I. 08 1.08 I. 10

I. 10 I. 08 1.08 I. 10

X I. 10 I. 10 C>< I. II I. 08 1.08 I. I 0

I. II I. 07 I .07 I. 09

C>< I. 08 I. 08 C>< I. 06 1.0~ I. 0~ I. 06

I. 0 I 1.00 I. 00 I. 0 I

1.08

1.08

I. 10

I. 08

1.07

1.08

I. Ol+

I. 00

I. 08

I. 10 >< 1.08 I. II I. 09

I. 07 I. II I. II C>< 1.08 C>< 1.09 1.07 1.03

1.0~ 1.06 1.03 1.02 1.00 0.98

I. 00 I. 0 I 1.00 0.99 0.98 0.98

CALLAWAY PLANT

FIGURE 4.3-13

627~-7

0. 981

Rev. OL-0 6/86

RODWISE POWER DISTRIBUTION IN A TYPICAL ASSEMBLY NEAR END-OF­LIFE, HOT FULL POWER, EQUILIBRIUM

XENON;UNRODDEDCORE

0::: w 3:: 0 a...

a w N

_j

<(

::::E 0::: 0 z:

13,557-17

2.Qr--------------------------------------------------,

I. 5

1.0

0.5

0.0 0 0.1

p =

D =

AO =

0.2

r = I .c ,,

= ) . I C'

AO = -8. t I

P = NORMALIZED POWER

D = FRACTIONAL INSERTION OF BANK D

AO = AXIAL OFFSET (PERCENT)

0.3 0.4 0.5 0.6 0.7

p = 0. 5

D = 0. I

;,() = 5.91

0.8 0.9 1.0

FRACTION OF ACTIVE CORE HEIGHT FROM BOTTOM

CALLAWAY PLANT

FIGURE 4.3-14

REV OL-13 05/03

TYPICAL AXIAL POWER SHAPES OCCURRING AT BEGINNING-OF-LIFE

(CYCLE 1)

0:::: LJ..I 3:: 0 0..

0 I..L.I N

_J <(

:::E 0:::: 0 z:

13,557-18

2.0 .---------------------------------------------------~

p :::: 0. 5

D ::: 0. 55

AO = -26.03 p 0. 5

I. 5 o 0.21 AO ::: 8. 20

1.0

P NORMALIZED POWER D FRACTIONAL INSERTION OF BANK D

AO AXIAL OFFSET (PERCENT)

0.5

0.0 ~--~----~----~----~--~----~----._--~----~--~ 0.0 0.1 0.2 0.3 0.~ 0.5 0.6 0.7 0.8 0.9 I. 0

FRACTION OF ACTIVE CORE HEIGHT FROM BOTTOM

CALLAWAY PLANT

FIGURE 4.3-15

REV OL-13 05/03

TYPICAL AXIAL POWER SHAPES OCCURRING AT MIDDLE-OF-LIFE

(CYCLE 1)

0:: LLJ

~ Cl..

0

13.557-19

2.0 ~------------------------------------------------------~

I .5

p = 0. 5

D = 0.62

A0=-25.7

0.5

0.61

6.59

~ 1.0 ...J <t :::::E: 0::: 0 z:

0.5

P = NORMALIZED POWER

D = FRACTIONAL INSERTION OF BANK D

AO = AXIAL OFFSET (PERCENT)

0.0 ~----~--~~--~----~----~----~----~----~----~--~ 0 0. I 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 I. 0

FRACTION OF ACTIVE CORE HEIGHT FROM BOTTOM

CALLAWAY PLANT

FIGURE 4.3-16

REV OL-13 05/03

TYPICAL AXIAL POWER SHAPES

OCCURRING AT END-OF-LIFE (CYCLE 1)

I. 5

I .0

0::: w ~ 0 0....

w > f-<l: _J

w 0:::

_J

<l:

>< <l: 0.5

0.0

CORE BOTTOM

CORE AVfRAGE

ADJACENI TO D BANK

REMOVED FROM D BANK

PERIPHEqAL LOW POWER ASSEMBLY

CORE HEIGHT CORE TOP

CALLAWAY PLANT

Rev. OL-0 6/86

FIGURE 4.3-17 COMPARISON OF A TYPICAL ASSEMBLY

AXIAL POWER DISTRIBUTION WITH CORE AVERAGE AXIAL DISTRIBUTION

BANK D SLIGHTLY INSERTED

CALLAWAY - SP

FIGURE 4.3-18 HAS BEEN DELETED

Rev. OL-9 5/97

CALLAWAY - SP

Figure 4.3-19 has been deleted.

Rev. OL-4 6/90

CALLAWAY - SP

FIGURE 4.3-20 HAS BEEN DELETED

Rev. OL-9 5/97

~ w s: 0 0..

>< N" 0 u.

>< < ::!!

2.6 .--------------------,-----------------------------------------,

2.4

2.2

2

1.8

1.6

1.4

1.2 ~

0.0

Fq Ht. (ft) 2.50 0.0 2.50 6.0 2.31 12.0

2.0 4.0 6.0

CORE HEIGHT (FT)

8.0 10.0 12.0

CALLAWAY PLANT

FIGURE 4.3-21

HAXIMUM FoX POWER VERSUS AXIAL HEIGHT DURING NORMAL

OPERATION REV. 14 10/09

0::: w 3

20.0

l5. 0

2i: 10.0 0::: ex: w z ....... _J

:..! ex: w 0...

5.0

0.0 -50.0

0 c.Pcfj ~ CD o --ooo o

0

-25.0 0.0

8555-74-

25.0 50.0

FLUX DIFFERENCE (~I)

CALLAWAY PLANT

FIGURE 4.3-22

Rev. OL-0 6/86

PEAK LINEAR POWER DURING CONTROL ROD MALFUNCTION

OVERPOWER TRANSIENTS

........ 1-1..1... -~ .........

0:: LIJ 3 0 c.. 0:: <( LIJ z: -....J

:.::: <( LIJ c..

20.0

15.0

10.0

5.0

0.0 -50.0 -25.0

8555-75

0.0 25.0 50.0

FLUX DIFFERENCE (61)

CALLAWAY PLANT

FIGURE 4.3-23

Rev. OL-0 6/86

PEAK LINEAR POWER DURING BORATION/DILUTION OVERPOWER

TRANSIENTS

0.759 0.792

4.3''

0~ 774 I. 255 0.800 I. 249

3.4% -0. 5;:{

I. 229 I. 225 -0, 3'c

I. 109 I. 077 I. 107 1.092

-0.2/c· I. 4'1,

I. 202 I. 223 I. 170 I. 256 -2.7fc 2. 7'/;

0.523 1. 217 I. 221 o. 548 I. 203 I. 233

4.6% I. I% t.or,

'· 229 I. 189 -3. 3~

I. 217 I. 224 0. 6'

I. 217 I. 211 -0.5;:

I. 229 I. 218 -0.9'1

I. 229 I. 220 -0.7%

-F z

~H :

FN Q

I. 217 I. 210 -0.6;~

~ CALCULATED ...___ MEASURED ~DIFFERENCE

PEAKING FACTORS 1.5

1.357

2.07

REVOL-13 05/03

CALLAWAY PLANT

FIGURE 4.3-24

COMPARISON BETWEEN TYPICAL CALCULATED AND MEASURED RELATIVE FUEL ASSEMBLY

POWER DISTRIBUTION

a:: UJ 3: 0

1.4-

1.2

1.0

::. 0.8 > I-< ....J UJ a:: ....J < >< <

0.6

0.4-

0.2

0 BOTTOM

10 20 30 4-0 50

CORE AVERAGE FROM INCORE MAP

AO = 2% ------

60 70

BOL NO XENON POWER AT 70% BANK D 25% INSERTED

80 90 100 PERCENT OF CORE HEIGHT TOP Rev. OL-0

6/86

CALLAWAY PLANT

FIGURE 4.3-25

COMPARISON OF TYPICAL CALCULATED AND MEASURED AXIAL SHAPES

X REACTOR I 0 REACTOR ~ V REACTOR 2 • REACTOR 5

0 FQ

e REACTOR 3

0

0 3.0

• 0

• • \1 2.5

\1 \7;< o• • X

0 \1 0 • • X \1 X X •

•o• • X ~X X • ii. • xx ~ ~

0 X • • 0 0 \1 'V5l_C>. 0

• 0 ~ oo

• •• 8 ~f

• ~~ 0

Olo 0 <c. 9

~ •• 0~ X

1.5 ,e

I ·r ·~ -50 -~5 -~ -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30

INCO~E AXIAL OFFSET (%) Rev. OL-0 6/86

CALLAWAY PLANT

FIGURE 4.3-26

MEASURED VALUES OF FQ FOR FULL POWER ROD CONFIGURATIONS

u... 0 -::::E <..:> c...

'+­'+­<V

1-'1:> -a. '1:>

~

1-z: UJ

<..:>

u... u... UJ 0 <..:>

UJ 0::: ::::> I­<( 0::: UJ a.. ::::E UJ I-

0::: UJ ....I a.. a.. 0 Cl

-I.~

-I. 6

-I. 8

-2.0

-2.2

-2.~

-2.6 500

13,557-20

600 700 800 900 I 000 II 00 1200

EFFECTIVE FUEL TEMPERATURE Teff (°F)

CALLAWAY PLANT

FIGURE 4.3-27

Rev. OL-0 6/86

TYPICAL DOPPLER TEMPERATURE COEFFICIENT AT BOL AND EOL,

CYCLE 1

f-z: LJ..J---- 0::: (..) LJ..J -~ u... 0 u... 0... LJ..J 0 f-(..) z:

LJ..J 0::: (..)

LJ..J 0::: ~LJ..J 0 0... o....-

::::E >- (..) --' 0.... z:-0

0. 0::: ~ LJ..J-_J 0. 0.... 't:> 0.... 0 0

-10

-12

-1~

-16 0

13.557-21

20 ~0 60 80 I 00

POWER LEVEL (PERCENT OF FULL POWER)

CALLAWAY PLANT

FIGURE 4.3-28

Rev. OL-0 6/86

TYPICAL DOPPLER-ONLY POWER COEFFICIENT AT BOL AND EOL,

CYCLE 1

0

:::E (..) 0...

0. -500

. I-(..) UJ u.. UJ 0

0::: UJ 3: 0 0...

>-....I z: 0

0::: -1000 UJ ....I 0... 0... 0 0

-1500 0

13.557-22

20 40 60 80 I 00

POWER LEVEL (PERCENT OF FULL POWER)

CALLAWAY PLANT

FIGURE 4.3-29

Rev. OL-0 6/86

TYPICAL DOPPLER-ONLY POWER DEFECT AT BOL AND EOL, CYCLE 1

20

1..1.. 0 -~ c...> 10 ~

~ 1-'1:> -Q.

"' 0 ~

I-z: 1J.J

c...>

u.. - 10 1..1..

1J.J 0 c...>

1J.J 0::: ::I 1-

-20 <( 0::: 1J.J ~ ~ 1J.J 1-

0::: -30 0

1-<( 0::: 1J.J c 0 ~

-40 0 100

13,557-23

2000 PPM

200 300 400 500 600

MODERATOR TEMPERATURE (OF)

CALLAWAY PLANT

FIGURE 4.3-30

Rev. OL-0 6/86

TYPICAL MODERATOR TEMPERATURE COEFFICIENT AT BOL, CYCLE l,

NO RODS

u... 0 -:::E c.> 0.. -

:::E f-"'0 -a. "'0 ~

f-z: u..J

c.>

u... u... u..J 0 c.>

u..J c:t:: ::::::> f-c:( c:t:: u..J 0.. % u..J f-

c:t:: 0 f-c:( c:t:: u..J 0 0 %

20

10

0

- 10

- 20

-30

-40

-50 0 I 00

13,557-2~

UNRODDED

200 300 400 500 600

MODERATOR TEMPERATUR~ (°F)

CALLAWAY PLANT

FIGURE 4.3-31

Rev. OL-0 6/86

TYPICAL MODERATOR TEMPERATURE COEFFICIENT AT EOL, CYCLE 1

1...1.. 0 -:::E <:..:> Q..

:::E 1-

~ a. -5

't:l

<:..:> -10 1...1.. 1...1.. I..LJ 0 <:..:>

I..LJ

~ -15 1-<( oc I..LJ Q.. :::E I..LJ

1- -20 oc 0 1-<( oc I..LJ 0 0 :::E -25

13,557-25

-30L---------------L---------------~--------------~ 0 500 1000 1500

SOLUBLE BORON CONCENTRATION {PPM)

CALLAWAY PLANT

FIGURE 4.3-32

Rev. OL-0 6/86

TYPICAL MODERATOR TEMPERATURE COEFFICIENT AS A FUNCTION OF BORON CONCENTRATION AT BOL,

CYCLE 1, NO RODS

LJ... 0 -~ u Q...

~ 1-~ -a. ~

1-:z: LJ.J

u LJ... LJ... LJ.J 0 u LJ.J 0::: :::::1 1-<( 0::: LJ.J Q...

~ LJ.J 1-

0::: 0 1-<( 0::: LJ.J 0 0 ~

0

-5

-10

-15

-20

-25

-30

-35

-ItO 0 5000 10000 15000

BURNUP (MWD/MTU)

CALLAWAY PLANT FIGURE 4.3-33

13.557-26

20000

REV OL-13 05/03

TYPICAL HOT FULL POWER TEMPERATURE COEFFICIENT DURING CYCLE 1 FOR THE CRITICAL BORON

CONCENTRATION

-12

-II+

I- 0::: z:: LLJ

~~ (.)c...

I.J...I-- -16 LJ... z:: LLJ LLJ 0 (.) (.) 0:::

LLJ 0::: c... LLJ-3:::::e:: 0 (.) -18 c... c... -_J

<(C... I- l't)

o-I- 0..

l't)

-20

-22

~

I--

1--

I--

I--

0

13,557-27

l,

/EOL

1 I J I 20 ItO 60 80 I 00

POWER LEVEL {PERCE~T OF FULL POWER)

CALLAWAY PLANT

FIGURE 4.3-34

Rev. OL-0 6/86

TYPICAL TOTAL POWER COEFFICIENT AT BOL AND EOL, CYCLE 1

0

-500

~ (..) Q..

-1000 Q.

. I-(..)

LJ.J LL.. LJ.J 0

a::: u.J ~ 0 Q.. -1500 .....J < 1-0 1-

-2000

-2500 0 20

13.557-28

ItO 60 80 I 00

POWER LEVEL (PERCENT FULL POWER)

CALLAWAY PLANT

FIGURE 4.3-35

REV. OL-7 5/94

TOTAL POWER DEFECT AT BOL AND EOL, CYCLE 1

13,557-29

R p N M L K J H G F E D c B A

I I I I

180° I

I SA B c B SA 2

so SB SB sc 3

SA D SE D SA

sc so 5

B c A c B 6

SB SB 7

c SE A D A SE c - 270°- 8

SB SB 9

B c A c B 10

so sc II

SA D SE D SA 12

sc SB sB So 13

SA B c B SA Itt

15

00

CONTROL NUMBER SHUTDOWN NUMBER BANK OF RODS BANK OF RODS

A It SA 8 B 8 SB 8

sc It

so It

c 8 D 5

TOTAL 25 SE It

TOTAL 28 Rev. OL-0 6/86

CALLAWAY PLANT FIGURE 4.3-36

ROD CLUSTER CONTROL ASSEMBLY PATTERN

CALLAWAY SP

FIGURE 4.3-37 HAS BEEN DELETED

REV. OL-5 6/91

160

150

140

130

120

110

,....... 100 Vl w I 90 {) z '-'

z 80 0 E 70 Vl 0 a. 60

50

40

30

20

10

0 0 0.4 0.8 1.2 1.6 2

TI~E OF TRAVEL (SECONDS)

THIMBLE DASHPOT

2.4 2.8 3.2

REV. OL-5 6/91

CALLAWAY PLANT FIGURE 4.3-38

DESIGN TRIP CURVE

1-0 1-

0. -0.

1.0

0.5

0.0 100 50

ROD POSITION (PERCENT INSERTED)

CALLAWAY PLANT

FIGURE 4.3-39

13.557-31

0

Rev. OL·O 6/86

TYPICAL NORMALIZED ROD WORTH VERSUS PERCENT INSERTION, ALL

RODS OUT BUT ONE

5 ~----------------------------------------------------------------------------,

0

........ !it: -5 LLJ (..) or:: LLJ

-==--10 1-LLJ (/)

LL. -15 LL. 0

_J

<C

>< -20 <C

;..25

CURVE I

CURVE I 2

BURN UP (MWD/MTU)

1550 7700

PERIOD (HOURS) 32.lJ. 27.2

STABILITY INDEX {HOURS-I)

-O.OlJ.I -O.OilJ.

-30 ~--~--._--~--~--~--_.--~--~----~--~--~--~--~--_.--~--~--~~~ 0 32 36 4-0

TIME (HOURS)

CALLAWAY PLANT

FIGURE 4.3-40

72

Rev. OL-0 6/86

AXIAL OFFSET VERSUS TIME, PWR CORE WITH A 12 FOOT HEIGHT

AND 121 ASSEMBLIES

~

...--.. :::::1'"

1-z: < a:: 0 < ;::) 0"

N

1-z: < a:: 0 < ;::) 0"

LJ.J (...) z: LJ.J a:: LJ.J LL.. LL..

0

1--I

1-

1-z: < a:: 0 < ;::) 0"

10

8

6

~

2

0

- 2

- ~

- 6

- 8

-10

-12

-I~

-16 0

STABILITY INDEX= -0.076 (HR.-I)

RCC E-ll

N~3 N~l

~ 8 12 16 20 2~ 28 32 36 ~ ~~ ~8 52 56 60 6~

HOURS AFTER WITHDRAWAL OF RCC E-1 I

CALLAWAY PLANT

FIGURE 4.3-41

Rev. OL-0 6/86

X-Y XENON TEST THERMOCOUPLE RESPONSE QUADRANT TILT DIFFERENCE VERSUS TIME

-60.0

-50.0

c.. ~

E' -~o.o (.) 0.

1-:z: UJ

u -30.0 LL. LL. UJ 0 u

ffi -20.0 ....J "-0... 0 0

-10.0

0 0 10

0 CONTROL BANK COMPENSATION

BORON COMP EN SAT I ON

--- EXPERIMENT ---CALCULATION

20 30 40 50 60 PERCENT OF FULL POWER

-2~00

-2200

-2000

-1800 E' (.) 0.

-1600 ::-u UJ

-I ~00 t!:i 0

-1200 ec:: UJ ....J 0... 0...

-1000 0 0

....J

-800 < ec:: <.!) UJ

-600 1-:z:

-~00

-200

0 70 80 90 100 Rev. OL-0

6/86

CALLAWAY PLANT

FIGURE 4.3-42 CALCULATED AND MEASURED DOPPLER DEFECT AND COEFFICIENTS AT BOL,

2-LOOP PLANT, 121 ASSEMBLIES, 12 FOOT CORE

CALLAWAY SP

FIGURE 4.3-43 HAS BEEN DELETED

REV OL-13 05/03

CALLAWAY SP

FIGURE 4.3-44 HAS BEEN DELETED

REV OL-13 05/03

CALLAWAY SP

FIGURE 4.3-45 HAS BEEN DELETED

REV OL-13 05/03

CALLAWAY - SP

Figure 4.4-1 Deleted.

Rev. OL-1 6/87

CALLAWAY - SP

Figure 4.4-1 a Deleted

REV. OL-~15 5/06

CALLAWAY - SP

Figure 4.4-2 Deleted.

Rev. OL-1 6/87

N-

t:: 1 .2 a: J: 1.1 ' ::I 1-~ 1.0 X ::I it 0.9 1-~

~ 0.8 ..J ~ (.) 0.7 E a: (.) 0.6 0 w a:

0.5 ::I (fJ

~ w 0.4 :E (fJ

~ 0.3 :E

Iii"' 0.2 0 ....

' u. ~ 0.1

E: 0

0 0.1

0 14-A-20766-180

0.2 0.3 0.4 0.5 0.6 0.7

95/95*

* 95% OF DATA WILL FALL ABOVE THIS LINE WITH 95% CONFIDENCE.

0.8 0.9 1.0

+ +

1.1 1.2

(q"CHF/106) PREDICTED CRITICAL HEAT FLUX (BTU/HR-FT2)

CALLAWAY PLANT

FIGURE 4.4-2a

Rev. OL-1 6/87

MEASURED VERSUS PREDICTED CRITICAL HEAT FLUX· WRB-1 CORRELATION

1.3

1.10

1.00 -N

t: 0.90 I

a: X ....... ;:)

0.80 ti -~ ;:)

0.70 -' ..... .... cC w

0.60 X

-.1. u -.... 0.50 ..... a: u c

0.40 ""' a: ;:) en cC

0.30 w :E . ~ 0.20 ---+--~~-f----1----+---+---+ ..... • '*951 of data w111--t----t ~ fall above this ~ line with 951 "&... 0.10 confidence.

X zu CT - o.oo~~~ .. ~~~~~~~~~~ .. ~~~~~~~~~~~~ .. ~

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90

(QCHF/106

,,.'RED, PREPICTED CRITICAL HEAT FLUX (8TU/HR-FT2)

1.00 1.10

REV. 16 10/06

CALLAWAY PLANT

FIGURE 4.4-2b MEASURED VERSUS PREDICTED

CRITICAL HEAT FLUX WRB-2 CORRELATION

CALLAWAY - SP

Figure 4.4-3 Deleted.

Rev. OL-1 6/87

CALLAWAY PLANT

FIGURE 4.4-3a

MEASURED VERSUS PREDICTED CRITICAL

HEAT FLUX – ABB-NV CORRELATION

Rev. OL-21b

4/16

CALLAWAY PLANT

FIGURE 4.4-3b

MEASURED VERSUS PREDICTED CRITICAL

HEAT FLUX – WLOP CORRELATION

014-A-20766-180

0.12

0.10 i-

0.08 1--

~ 0.06 ~

0.04 t-

0.02 i-

0 I 0 1.0

0

I I 2.0 3.0

I 4.0

G De Re=}L (lo- 5 )

I

5.0

LEGEND:

0 26" SPACING I -PHASE

0 26" SPACING 2-PHASE

0 0 0

I I 6.0 7.0 8.0

CALLAWAY PLANT

FIGURE 4.4-4

Rev. OL-0 6/86

TDC VERSUS REYNOLDS NUMBER FOR 26 INCH GRID SPACING

9 1.029 1.001

l

10

I I

I l.l53

1.000

J 1. Iss I .000

J 12 1.223

I .000 I

J 13

I. 126

I .001 J

I 14 1.025

I

15 0.717 0.999

014-A-20766-181

G F E 0

-1--- --- ---

c

--:-

B A KEY:

-r-- .6.h/.6.h G/G

DDDDDD [;]DDDDD [;][;]DODD ~~~DO ~~~[fBD [[;]~[[;]§

§§ FOR RADIAL POWER DISTRIBUTION NEAR BEGINNING OF LIFE. HOT FULL POWER, EQUILIBRIUM XENON

CALCUAL TEO F~H = l . 34

(CYCLE l ONLY)

CALLAWAY PLANT

Rev. Ol-1 6/87

FIGURE 4.4-5 NORMAliZED RADIAl FLOW AND

ENTHALPY DISTRIBUTION AT 4 FOOT ELEVATION

~I H G F E 0 c B A

~1.096 __

8 0.996 -f--f- -f--f- -f- --- ---

KEY: -- l:.h/b.h

G/G

1 9 1.026

1.002 L

I I. 155

I O 0.991

I I I I. 169

0.990

1 12 1.228

0.985

1 13

I. 129

0.992 L

I 14 1.024

1.900

I o.-715

15 1.022

014-A-20766-182

§DDDDDD §§DDDDD §~§DODD ~[;][;]~DO §[;]~rnmo

~[;]~~~ [ill]~~

FOR RADIAL POWER DISTRIBUTION NEAR BEGINNING OF LIFE. HOT FULL POWER, EQUILIBRIUM XENON

N CALCUAL TED F L'.lH = I . 34

(CYCLE I ONLY)

CALLAWAY PLANT

Rev. OL-1 6/87

FIGURE 4.4-6 NORMALIZED RADIAL FLOW AND

ENTHALPY DISTRIBUTION AT 8 FOOT ELEVATION

ct_J H ct_ I

_I. 0971--1-

B o.T95

I

I. l57 10

o.r91

I I

I I. ;70 0.990

I

I 1.231

12 0.987

I

I I. ;30

13 o.r93

I 14

1.023

I

15 0. 711 1.016

014-A-20766-183

G F E 0

-1-- --r-

c B

-r-r-

A

KEY: -- L'.h/ L'.h

G/G

DDDDDD §DDDDD ~§DODD §§§DO §§E§~D [;][§[U]~ [;][§

FOR RADIAL POWER DISTRIBUTION NEAR BEGINNING OF LIFE. HOT FULL POWER, EQUILIBRIUM XENON

CALCUAL TEO F~H = I . 34

(CYCLE I ONLY)

CALLAWAY PLANT

Rev. OL-1 6/87

FIGURE 4.4-7 NORMALIZED RADIAL FLOW AND

ENTHALPY DISTRIBUTION AT 12 FOOT ELEVATION- CORE EXIT

CALLAWAY - SP

Figure 4.4-8 Deleted

REV. OL-~15 5/06

0.07

() 0

I

~ () "-3: t:. ~

> 1-

LEGEND: PERCENT PERCENT 0 u THEORETICAL THEORETICAL 0.06

\· DENSITY DENSITY

0 GYLLANDER 96.4 0 HOWARD & GULVIN 96.0

0~ • ASAMOTO 95.0 • LUCKS & DEEM··· 96.5

\o 0 GODFREY 93.4 ()DANIEL ET Al. 96.5

0.05 A STORA 92.2 • FEITH 97.9 0 0 A.D. BUSH 94.4 0 VOGT ET AL. 97.0

<>,t • ASAMOTO 91 .. 0 6. NISHIJIMA 95.0

0 \ 'V KRUGER 93.7 '9' WHEELER & 97.0

> 1-(.) :::> 0 2 0 ()

...I

-1 <(

:r (') ~ -<D a:

-1~3 :t> w :r ..... w "'-:; r- :X: (DOl_ H r- 1-~()("') GJ :t> <D 0 0 c

~ ~-::: ::J " nroa. tTl :t> Ill () c - .... ()

""' -< o~=· <D < , :J ,... ;:;: ""' (1)0-< I r-

0.04 g't AINSCHOUGH

o't SEE REFERENCES FOR THERMAL-HYDRAULIC SECTION

0~· 6.

0.03 ~-~· 0 • o' o• • t • 6. ~'~·~ co 0 t

0 •'V'V'V~~-~--o 0.02

6. ... •

rl. (.0 0 1.0 :t> $01-Cf<C z

0 -4 0.01 ~------~------~--------~------~--------~------~--------~----_j

0 400 2800 3200 800 2000 2400 1200 1600 N

en ::a ....... (])

~< TEMPERATURE (T), °C

0 r 6

620

610

600

LL 590 0

w 580 0::: ~ 1-<{

570 0::: w Cl. 2: w 560 1-

550

540

530 0 20

0 14-A-20766-184

TcOLD (556.8)

40 60 80 100

PERCENT POWER

CALLAWAY PLANT

FIGURE 4.4-10

REV. OL-15 5/06

REACTOR COOLANT SYSTEM TEMPERATURE-PERCENT POWER MAP

0 H

f-<( a: rlJ z 0

:L :::.) :L H

z H

:L

I .8 ~------------------------------------------------~

~~-5 BOL I +5 ... , I. 7

, .. 5 FOL I +5 ,...,

I .6 0 0

§';s>~ ~\o I .5

0 d>o ~ o0 o B~o 0

0 0 0

0 I. 4

<co

I .3 I . 55 COSINE tl

I .2 ~--------------~----------------~--------------~ -20 -10 0 10

AXIAL OFFSET (PERCENT)

Rev. OL-1 6/87

CALLAWAY PLANT

FIGURE 4.4-11 100% POWER SHAPES EVALUATED AT

CONDITIONS REPRESENTATIVE OF LOSS OF FLOW, ALL SHAPES EVALUATED

WITH FNAH = 1.55

014-A-20766-185 (CYLE 1 ONLY)

CALLAWAY - SP

figure 4.4~12 Deleted.

Rev. 01-1 6/87

CALLAWAY - SP

Figure 4.4-13 Deleted.

Rev. OL-1 6/87

CALLAWAY - SP

Figure 4.4-14 Deleted.

Rev. 01-1 6/87

CALLAWAY - SP

Figure 4.4-15 Deleted.

Rev. OL-1 6/87

CALLAWAY - SP

Figure 4.4-16 Deleted.

Rev. OL.,..l 6/87

CALLAWAY - SP

Figure 4.4-17 Deleted.

Rev. OL-0 6/86

CALLAWAY - SP

Figure 4.4-18 Deleted.

Rev. OL-0 6/86

CALLAWAY - SP

Figure 4.4-19 Deleted.

Rev. OL-0 6/86

CALLAWAY - SP

Figure 4.4-20 Deleted.

Rev. OL-0 6/86

2 3 4-

D

T T

D

T T

D D

T T

T D D D

D T T

D

T T

TO TD

D

13,'i57-32

5 6 7 8 9 10 II 12 13 14- 15

I I I I

I I I 270° I

T T D T D A

D D D B

D T D TO T T T c

D D D D D

D T T D T D T T E

D D D F

D T T D T TD T -- G

D D D TD -oo- H

T D TO TD T TD J

D I) -- K

D T TD TO D T D 1 D -- L

D

TO TO T T D TD

D p

TD TO T D R

T = THERMOCOUPLE (50 LOCATIONS) D = MOVABLE INCORE DETECTOR (58 LOCATIONS)

CALLAWAY PLANT FIGURE 4.4-21

DISTRIBUTION OF INCORE INSTRUMENTA'riON

Rev. OL-0 6/86