camcontain camvent - camfil

2
CamContain CamVent Non-Intrusive Filter Validation Biocontainment Venting System www.camfil.com The Camfil CamContain CamVent is a slim and compact HEPA air filtration system. The CamContain CamVent: • Is the ideal solution for HEPA-filtering plumbing vent stacks in high containment areas. • Provides HEPA filtration for toxic displaced air from storage tanks. • Used as a HEPA-filtered transfer system between rooms to minimize pressure pulses created by personnel doors. • Allows scanning of filters with the non-intrusive CamControl system. By adding an optional blower pack and the CamControl scanning package, non- intrusive scanning of the HEPA filter is possible for in-situ validation. At 50 CFM, the total resistance of CamVent does not exceed 1.2″ w.g. with a 99.99% Absolute filter installed. SafeScan CV Capability • The SafeScan CV assembly allows for non- intrusive in-place scanning of the unit’s HEPA filter. • As an option, an automated scanning mechanism allows for validation tests to be conducted from the roomside while labs are operational, eliminating downtime and minimizing the risk of contamination of adjacent spaces. •The entire surface of the filter and the media to frame joints are scanned for leaks. The filter may be validated in-situ to on-site to IEST-RP-CC-007. The assembly also allows the use of Camfil’s optional CamControl or Motion Control Lite filter validation system.

Upload: others

Post on 17-Feb-2022

13 views

Category:

Documents


0 download

TRANSCRIPT

CamContain CamVentNon-Intrusive Filter Validation Biocontainment Venting System

www.camfil.com

The Camfil CamContain CamVent is a slim and compact HEPA air filtration system.

The CamContain CamVent:

• Is the ideal solution for HEPA-filtering plumbing vent stacks in high containment areas.

• Provides HEPA filtration for toxic displaced air from storage tanks.

• Used as a HEPA-filtered transfer system between rooms to minimize pressure pulses created by personnel doors.

• Allows scanning of filters with the non-intrusive CamControl system. By adding an optional blower pack and the CamControl scanning package, non-intrusive scanning of the HEPA filter is possible for in-situ validation.

At 50 CFM, the total resistance of CamVent does not exceed 1.2″ w.g. with a 99.99% Absolute filter installed.

SafeScan CV Capability

• The SafeScan CV assembly allows for non-intrusive in-place scanning of the unit’s HEPA filter.

• As an option, an automated scanning mechanism allows for validation tests to be conducted from the roomside while labs are operational, eliminating downtime and minimizing the risk of contamination of adjacent spaces. •The entire surface of the filter and the media to frame joints are scanned for leaks. The filter may be validated in-situ to on-site to IEST-RP-CC-007. The assembly also allows the use of Camfil’s optional CamControl or Motion Control Lite filter validation system.

Manufactured under strict quality control procedures (CFW-10001), all welding procedures, are qualified in accordance with ASME Boiler and Pressure Vessel Code, Section IX. The program also meets the Quality Assurance requirements of NQA-1.

Fully welded.

The complete assembly pressure boundary is leak tested by the pressure decay method per ASME N510-1995 Reaffirmed, Testing of Nuclear Air Cleaning Systems.

CamContain CamVent with optional mounting assembly (graphic right).

www.camfil.com

© C

opyr

ight

Cam

fil U

SA #

342

6 - 1

017

ASME NQA-1QUALITY PROGRAM

CERTIFIEDQUALITY SYSTEM ISO

9001:2008

NQA-1

Camfil | 1 North Corporate Drive, Riverdale, NJ 07457 | Tel: (973) 616-7300

Camfil products meet the requirements of ASME NQA-1, Quality Assurance for Nuclear Facility Applications.

For detailed specifications or drawing, please consult your local Camfil Distributor or Representative or download from the Containment Toolbox located in the Segments Tab of CamTab File Archive at www.camfil.us.Camfil has a policy of uninterrupted research, development and product improvement. We reserve the right to change designs and specifications without notice.

For assistance specific to this product please contact Camfil’s Washington, NC facility at [email protected] or telephone at (877) 658-6588.

CamContain CamVentNon-Intrusive Filter Validation Biocontainment Venting System

Notes:Housing includes quick disconnect pull rings for sealing housing gaskets.Installed weight 100 pounds.Three feet of clearance in front of the scan actuator interface side is recommended to facilitate filter change. Butterfly isolation dampers are standard as are bolt flange connections.Optional reducer fitting for smaller diameter connections.

RDC

N/A

APPROVEDAPPROVAL PRINT

REVISE AND RESUBMITAPPROVED AS NOTED

DATE:SIGNATURE:REQUI

RED

CUSTOMERACTION

38" (965MM) MIN42" (1067MM) MAX

FLANGETO

FLANGE

DECON PORT1 1/4" BALL VALVEW/ CAM-LOCK COUPLER& DUST PLUG (TYP. 2)

SCAN KNOB/MOTOR MOUNT

QUICK DISCONNECTPULL RING (TYP. 3)

6" INLET/OUTLETBUTTERFLY VALVE

UPSTREAM SAMPLE PORTW/ 1/4" QUICK CONNECT FITTING

SCAN PROBE PORT1/4" COLOR KEYEDQUICK DISCONNECT

6" INLET/OUTLETBUTTERFLY VALVE

AIRFLOW LABEL

HOUSING I.D. LABEL

16 1/8"

18 3/16"

11"O.D.

6 9/32"I.D.

13/16" THRU(8) PLACES

EQUALLY SPACEDON A 9 1/2" B.C. AS SHOWN

INLET/OUTLETFLANGE DETAIL

INLET/OUTLETVIEW

ACCESS VIEW

Specifications For CamVent Pipe Containment System1.1 Housing Design:System shall be Camfil Biocontainment Vent System designed to be permanently installed in vent pipe and allow in-place scan testing of a removable HEPA filter in accordance with IEST-RP-CC034.1. System housing that forms the external pressure boundary shall be fabricated from minimum 14 ga. 304 SST. HEPA filter sealing mechanism shall feature gasketed quick-connect fittings to facilitate filter changeout and be designed so that filter may be removed and replaced without having to remove an access door on the housing.

Scan mechanism shall be permanently installed in the housing and actuated from the exterior of the housing without having to remove access doors or otherwise breach the exterior pressure boundary of the housing or require removal of the HEPA filter. Upstream and downstream butterfly valves shall be provided to allow isolation of the system. Aerosol injection, upstream decon and downstream decon ports shall include SST ball valves with aluminum cam-lock fittings and aluminum dust plugs.

Welding And Cleaning:All welding procedures, welders and welder operators shall be quialified in accordance with ASME Boiler and Pressure Vessel Code, Section IX. All production welds shall be visually inspected by qualified personnel, per Camfil standard procedure number CFW-10001, Visual Inspection of Wedls, which incoporates the workmanship acceptance criteria described in Section 5 & 6 of AWS D9.1990, Specification for Welding of Sheet Metal.

Factory Testing And Quality Assurance:The filter sealing surface and the complete assembly pressure boundary shall be leak tested by the pressure decay method as defined in ASME N510-1995 Reaffirmed., Testing of Nuclear Air Cleaning Systems, paragraphs 6 and 7. The filter sealing surface and overall system pressure boundary shall be tested at +10" w.g. and have a maximum leakage rate of 0.0005 cfm per cubic foot of volume tested. System shall be manufactured in a facility that is certified to ISO 9001:2008 and manufacturer shall provide evidence of certification to ISO 9001:2008.

Sizes shall be noted on enclosed drawings or other supporting materials.

1.2 Vent Pipe HEPA Filter:Cylindrical axial flow HEPA filter shall be feature mimimum 14 ga. 304 SST frame, with integral flange that allows quick-connection to the Biocontainment Vent System. Filter media shall be formed into a pleated pack and sealed to the enclosing frame with fire retardant polyurethane sealant. The filter efficiency shall be a minimum of 99.99% at 0.3 micron when tested at rated airflow. Filter shall be manufactured in a facility that is certified to ISO 9001:2008 and manufacturer shall provide evidence of certification to ISO 9001:2008.

QUANTITY REQUIRED = (1) ONEAPPROXIMATE SHIPPING WEIGHT = 125 LBS. EA.

WASHINGTONNORTH CAROLINA

www.camfil.com

CAMFIL PART NO.:UNLESS OTHERWISE SPECIFIED TOLERANCES ARE:

CUSTOMER PO NO.:

DECIMAL:DRAWN BY:

FRACTION:

DATE:

CHECK BY: DATE:

APPR. BY: DATE:

DRAWING NO.: SHEET REV.OF

DRAWING TITLE:

SCALE:THE INFORMATION CONTAINED ON THIS DRAWING IS PROPRIETARY TO CAMFIL AND MAY NOT BE REPRODUCED NOR TRANSMITTED TO OTHER PARTIES WITHOUT THE CONSENT OF CAMFIL.

CHECK BYDATEDESCRIPTION:DRAWN BY

DATEREV. DATEAPPR. BY

SALES APPR: DATE:

1

1

A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

23456789101112

23456789101112

CAMVENT HEPA PLUMBING VENT

1:8 B 1 1 0M60001739

6/25/15 CF-NIFV-006-1GB/N-ASTS-SS-6

M60001739

JDN

1/8"0.125"

CUSTOMER: CAMFIL/EXFILCUSTOMER LOCATION:

CAMFIL ORDER NO.: Q171051

DWG SIZE

PB 6/25/15

6/25/15

N/A