campus signage manual

118
CAMPUS SIGNAGE MANUAL Prepared by the Facilities Management Unit 1

Upload: pramod329

Post on 04-Apr-2015

150 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Campus Signage Manual

C A M P U S S I G N A G E M A N U A LPrepared by the Facilities Management Unit

1

Page 2: Campus Signage Manual

Contents

Introduction pg 3

Section 1

Purpose pg 4

Using the campus signage manual pg 5

Signage Design pg 6

Signage rules pg 7

Campus Signage Statement pg 8

Glossary of terms pg 9

Procedures pg 10

Section 2

Signage Request Procedure pg 11

Requesting Commercial Signage Procedure pg 15

Permanent Standard Campus Signage Technical Specification pg 22

Section 3

Campus Map Signs pg 23

Campus Street Signs pg 26

Directory Board Signs pg 29

Building identification Signs pg 36

Corporate Identification Signs pg 40

Functional Area identification Signs pg 45

Blade Amenity Signs pg 48

Door Signs pg 98

Fire and Safety Signs pg 112

Car Park Entry Signs pg 114

Other Signs of Interest pg 116

Section 4

2

Page 3: Campus Signage Manual

I N T R O D U C T I O N

33

Page 4: Campus Signage Manual

Introduction

BackgroundThe Facilities Management Unit is responsible for ensuring that corporate standards are maintained in the development and implementation of all signage across the University. The Campus Signage Manual was developed in 2001 using a collaborative approach with key stakeholders across the University. Since then, there has been considerable effort in ensuring consistency in corporate standards is maintained for directional signage whilst ensuring opportunities to promote the University and its stakeholders are achieved. The manual provides clearly defined signage instructions for the design, development and installation of standardised signage on all campuses of the University. This manual will continue to be used as a basis in the development and implementation of improved signage across the University. PurposeThe purpose of the Campus Signage Manual is to provide tools and processes for the development and implementation of all University signage. This has ensured that the delivery of services to our stakeholders is enhanced through the appropriate use of directional and way-finding signage across all campuses. The University has also seen a progressive roll-out of corporate signage across all campuses since the implementation of these standards. Reference to relevant Australian and International Standards, Occupational Health, Safety and Welfare Regulations, and relevant Government and University Acts, guidelines and regulations are used to ensure compliance levels are maintained. Developing signage specificationsThe following way-finding principles are used in the development of new signage specifications: Signage designs shall be developed to complement existing signage and be

sympathetic with and contribute to the promotion of the University’s corporate image and market positioning.

Australian and International Standards shall guide the technical and physical aspects of all signage including compliance to regulatory signage.

Signage design shall overcome language and communication barriers where appropriate and instil the principals of way-finding.

Identification and location of buildings, facilities and services shall be quick and easy for internal and external customers of the University.

44

Page 5: Campus Signage Manual

About The ManualThe manual is presented in 5 sections Section 1Introduction Campus Signage Statement Glossary of Terms Section 2Standard Operating Procedures and Forms Section 3Signage Design Specifications Section 4Other Signs of Interest Using the Campus Signage ManualStakeholders (including external contractors and consultants) are able to use the information contained in the Campus Signage Manual to assist in determining their specific signage requirements:

Section 2 includes standard operating procedures and request forms that provide information on how to order your signage requirements.

Section 3 includes technical specifications for all corporate signage designs currently available. The technical specifications are sorted by relevant signage type to assist in identification of signage designs.

Section 4 provides a visual display of additional signage that has been

developed using elements of existing corporate standards and modified to suit the needs of stakeholders and or building design.

In all cases, modification has occurred with due consideration given to approved use of University logo and co-branding logo’s and is subject to change depending on the needs of individual stakeholder groups.

Distribution of the ManualThe Campus Signage Manual is available online at the following address: http://www.unisa.edu.au/facilities/contractors/signage.asp Copies of the manual are also available on request by contacting the Facilities Management Unit.

55

Page 6: Campus Signage Manual

Quality ManagementThe Campus Signage Manual is a quality document and as such shall be evaluated and updated at regular intervals. This includes formal auditing processes for all new and existing signage on campus to ensure:

Integrity of UniSA logo and style guide is maintained Compliance to legislative and corporate signage standards Maintenance of existing signage; and Implementation of new signage as required.

Signage DesignA coordinated and consistent approach in the format, construction, and use of text, graphics, materials, and colour has been used in the design of corporate signage documented in the Campus Signage Manual. To facilitate global understanding, the design of campus signage draws on three different forms of communication; written word, graphics and colour. Consultation regarding signage also occurred with staff, students and the RSB throughout the design phase in 2001 and again with signage consultants, internal stakeholders and the Royal Society for the Blind as part of the review phase in 2008/2009. There is an emphasis on ease of identification, which has been promoted through the placement of signage, use of colour and easily identified graphics. The use of colour also enables the grouping of particular amenities for easy identification. Classification, Types and Styles of Signage The Campus Signage Manual documents classification, types and styles of corporate signage. Signage across the University is sorted in the following manner: Classification of Signage Types of Signage Styles of Signage

Images are also provided of other signs of interest including major signage for new building programs that may be suitable for further use or adaption depending on the needs of the stakeholder group. Types of SignageEleven main types of signage are identified in the Campus Signage Manual: Campus Signature Campus Maps Directory Boards Building Identification Functional Area Identification Corporate Identification Blade Amenity Identification Door / Pigeon Hole Plates Evacuation Parking

66

Page 7: Campus Signage Manual

Manufacturing and InstallationTo assist with standardisation, cost effectiveness and quality of work, the manufacture and installation of signage is undertaken by the Facilities Management Unit with the use of appropriate external contractors and suppliers nominated on the relevant Contractors Register(s). Signage RulesA number of rules apply to the design and implementation of corporate signage to ensure consistency in placement, content and format of information: Examples of such rules include:

Standard font and size applied to all text using frutiger. Standard text used on door plates may include professional titles ie Dr,

Prof, and Associate Professor but do not include personal titles such as Ms, Mr, Miss.

Two metre clear space to be applied in surrounding area for directory boards

Staff names shall not be included on building and floor directory boards and information shall be alphabetised for consistency and ease of use

Use of University and co-branding logo’s shall comply with University style guide

Implementation of legislative signage standards in areas such Evacuation Plans, Fire & Safety and Hazardous Signage shall be consistent in size and placement:

o External - 250mm metal plate with vinyl attached or vinyl on glass if appropriate

o Internal - 150 mm using vinyl Approvals and Timelines Requests for new signage designs that do not form part of existing corporate signage standards must be approved by Facilities Management Unit to ensure design and intended use meet corporate guidelines relating to University logo, content and placement of signage design. Installation of all signage occurs on a rotational basis across all campuses and it is intended that any door signage is installed within 10 working days from placement of your initial signage request. Approvals and timelines for all other standard corporate signage will be negotiated with the customer, with consideration given to the urgency and type of signage required.

77

Page 8: Campus Signage Manual

Campus Signage Statement The University of South Australia is committed to providing suitable directional signage that meets the needs of our staff, students and general public. This statement reflects the processes documented in the Campus Signage Manual which have been established to ensure a standardised approach to the development and implementations of all signage across the University. The design and implementation of all signage shall reflect the standard technical specifications for individual signs documented in the Campus Signage Manual in terms of visual display, quality of work, and use of materials. Signage requirements that are extraordinary in nature and are not specified in the Campus Signage Manual shall be reviewed by the Business & Administration Coordinator, Facilities Management Unit for development and approval to ensure consistency in signage design and placement. All signage shall conform to the Campus Signage Manual and the University Branding and Style Guide which shall be developed in conjunction with rules, regulations and guidelines stipulated in appropriate legislation and standards. Standard operating procedures also provide step-by-step instructions relating to requests for corporate signage requirements. These procedures provide clearly defined actions and responsibilities for the development, implementation and review of signage across the University. The campus Signage Manual is a quality document and shall be subject to regular reviews as part of this University’s commitment to continuous improvement.

88

Page 9: Campus Signage Manual

Glossary of Terms

PurposeThe purpose of this section is to provide a list of descriptions and/or definitions of some of the terms used throughout the Campus Signage Manual. Commercial signage:Signage which is not documented in the Campus Signage Manual and which is associated with an external commercial provider or tenant located on University campuses. Directional signage:All types of signage that provides way-finding information to a specific location, building or service. External signage:Signage that is placed in an external environment on a University campus or building. Internal signage:Signage that is placed internally within buildings on a University campus. Major project signage:Signage that forms part of a major refurbishment or building program that may, or may not be documented in the Campus Signage Manual. New campus signage:Any signage proposal that is not documented in the Campus Signage Manual. Permanent standard campus signage:All signage documented in the campus Signage Manual. Temporary campus signage:Temporary campus signage are those signs which have been developed by internal and external customers on an ad-hoc basis for temporary purposes and are not defined as corporate standard signage.

99

Page 10: Campus Signage Manual

P R O C E D U R E S

1010

Page 11: Campus Signage Manual

STANDARD OPERATING PROCEDURE: Signage Request Procedure

1. Introduction This procedure has been developed to provide University stakeholders with appropriate information for ordering UniSA corporate standard signage including door signage and other signage designs.

2. Purpose

The purpose of this procedure is to outline the process for ordering, approvals and installation of corporate standard signage across all UniSA campuses.

3. Definitions

Corporate signage standards – refers to all signage designs approved for installation on University campuses.

4. Procedure

4.1 Requesting a Door Plate

Requests for all door signage shall use the Standard Door Plate Job Sheet (Form No: FMU-064). This form provides information on the type of signage required i.e. door plate style, vinyl text as well as the door type i.e. solid door, glass door.

4.2 Requesting Corporate Standard Signage

Requests for all other types of corporate standard signage shall use the Signage Request Form (Form No: FMU-065) where a detailed description of the signage requirements can be provided.

4.3 Approval of signage

It is the responsibility of the customer to provide a relevant cost centre and sign for approval prior to commencement of work.

4.4 Errors and Omissions

Any costs associated with errors and/or omissions to signage requests by the customer shall be charged to the respective cost centre.

11

Page 12: Campus Signage Manual

4.5 Signage Design and installation

Disability Access and Occupational Health, Safety and Welfare issues shall be identified prior to the design and placement of all campus signage to ensure appropriate placement of all internal and external signs in line with the relevant Act. These issues may include but are not restricted to: • Placement height of sign • Size of text • Use of colour and materials

4.6 Use of UniSA logo

The University of South Australia logo is a Registered Trade Mark and its use is controlled and managed by UniSA. The logo can be downloaded from the Marketing and Development Unit website for use in signage and other promotional and corporate material however strict use of the logo is maintained at all times.

Co-brand logos can also be used in signage designs which identify entities within UniSA like research centres, divisions and schools, and on occasion programs. Co-brands can also link UniSA with other organisations with which it has a partnership or relationship. The UniSA Logo Co-brand Framework provides the rationale and protocols for the branding format for the full range of collaborative alliances.

4.7 How to order signage

4.7.1 Customer forwards completed Signage request (FMU-065) or Door Plate Job Sheet (FMU-064) to Signage Officer which includes the relevant Cost Centre number and Authorisation Signature for expenditure

4.7.2 Signage Officer processes request form(s) and determines needs of

customer. 4.7.3 If signage request does not conform to corporate signage standards,

then Signage Officer will contact the customer to review the request and provide recommendations for appropriate signage.

4.7.4 Signage Officer may also visit site if appropriate to determine signage

requirements and discuss options for corporate standard signage or new signage design.

4.7.5 Signage Officer develops proof of signage design(s) ensuring integrity of

UniSA logo is maintained and forwards to customer for approval. 4.7.6 Customer provides email confirmation for approval of signage design

based on proof. 4.7.7 Signage Officer negotiates timeframe for signage to be manufactured

and installed and confirms location for installation. 4.7.8 Signage Officer proceeds with manufacture of signage request.

12

Page 13: Campus Signage Manual

4.7.9 If signage product is a new design then Signage Officer shall update the

Campus Signage Manual accordingly.

5. References

• Standard Door Plate Job Sheet FMU-064

• Signage Request Form FMU-065

• UniSA Branding and Style Guide

• UniSA Logo Co-brand Framework

• OHS Purchasing Procedure

• Building Code of Australia

• Disability Discrimination Act

• How to order signage flowchart

13

Page 14: Campus Signage Manual

No

No

Customer completesrelevant signage request form

and provides cost centre number and authorisation

for expenditure.

Signage O�cer processes request to determine needs of

customer.

Contacts customer todiscuss signage

options and provide recommendations.

Visit site if appropriate to review design and location

reqirements and provide recommendations if

appropriate.

Does signage request conform to corporate

standards?

Yes

Is customer happy with signage

design and cost?

Discuss issues with

customer and todetermine a

solution as required.

Signage O�cernegotiates timeframe for

manufacture and installation, con�rming

location for sign.

Signage O�cerproceeds with

manufacture and install of signage request.

Campus Signage Manual is updated with any new

signage design .

Signage Request Procedure Flow Chart

Signage O�cer develops proof ensuring integrity of

logo and forwards to customer for approval.

Yes

14

Page 15: Campus Signage Manual

SOP-FM-107

STANDARD OPERATING PROCEDURE: Requesting Commercial

Signage 1. Introduction

This procedure has been developed to provide University stakeholders and Commercial service providers with appropriate information for placing commercial on University campuses.

2. Purpose The purpose of this procedure is to provide efficient and effective processes for requesting commercial signage on University campuses by commercial service providers. This procedure applies to all internal and external customers of the University of South Australia.

3. Definitions

Commercial signage is signage which is not documented in the Campus Signage Manual and which is associated with a commercial group. Commercial provider(s) are any entity associated with the University of South Australia that has a commercial focus, and/or any entity which has a commercial presence on a University campus.

4. Procedure

4.1. Types of Commercial Signage

Examples of commercial signage may include but are not limited to: • Identification and/or image signage for the commercial group. • Amenity signage which is associated with a commercial group. • Advertising signage.

UniSA is committed to adhering to the Disability Access and Occupational Health, Safety and Welfare guidelines regarding the design and placement of all campus signage. 4.2 Approval process

• The Director of Facilities Management or their representative shall advise the

commercial service provider of approval or otherwise once application for requested signage is received.

• All requests for commercial signage shall be referred to the Facilities Management Unit’s Commercial Services for recommendation to the Director: Facilities Management Unit.

15

Page 16: Campus Signage Manual

• The Facilities Management Unit shall advise the commercial services provider of associated charges once application for commercial signage request is approved.

• Signage requirements that identify and/or are specific to a commercial customer shall be the responsibility of the respective commercial group and shall be funded by that group.

• Current market rates shall apply to all commercial signage unless otherwise directed in the formal contract negotiations.

4.3 Errors and Omissions Any costs associated with errors and/or omissions to signage requests by the commercial service provider shall be charged to the respective commercial customer’s group.

4.4 Commercial Signage Documentation

• Commercial service providers requiring a signage presence on University

campuses should make an application to the Facilities Management Unit: Commercial Services.

• A formal written agreement shall be established for commercial signage on University campuses in all instances.

• A commercial signage agreement pro-forma shall be developed by the Facilities Management Unit and utilised to ensure both parties adhere to agreement guidelines.

• Information contained in the agreement shall include but not restricted to: • Payment for signage design, construction and installation. • Cleaning and maintenance. • Replacement due to vandalism and/or general wear and tear. • Scope of sign i.e. Material, height, text etc. • Placement / location of sign(s) • Time frames for which action should be taken.

4.5 Requesting Permanent Commercial Signage 4.5.1 Commercial service provider contacts the Facilities Management Unit to discuss

signage requirements and forwards request in writing to the Commercial Services Manager, FMU.

4.5.2 Commercial Services reviews signage specifications and design and providers

recommendation to Director of Facilities Management for final approval. 4.5.3 If the Facilities Management Unit does not approve signage, feedback is provided

to the commercial service provider and the customer is required to submit a revised plan incorporating recommendations from the Facilities Management Unit.

4.5.4 Ongoing maintenance and cost implications for the signage shall be considered as

part of the Licence and Lease Agreement with UniSA.

16

Page 17: Campus Signage Manual

4.5.5 Commercial services provider arranges manufacture and installation of signage and advises Facilities Management Unit of contractor details, timing and installation requirements for approval.

4.5.6 Facilities Management Unit follows Contractor Management procedure and

advises Commercial Services Provider and Facilities Coordinator of impending work.

5 References • Contractor Management Procedure • Contractor Permit to Work

17

Page 18: Campus Signage Manual

Commercial Service Provider complets form PRO-004 commer-

cial Signage Request, gains required signatures and forwards

it to Commercial Services Manager, FMU.

Signage is recommended to the Director of FMU for

�nal approval.

Commercial Service Provider arranges for the construction of

signage and advises FMU of contractor details, timing and installation requirements for

approval.

Commercial Services approves contractor who will provide and install signage.

Commercial Signage Request Procedure Flow Chart

Commercial Services reviews signage

speci�cations

Is signage approved?

Yes

Is signage approved of Director

FMU?

Feedback isprovided and customer

requested to submit revised plan.

No

Contact customer to discuss signage options and provide

recommendations.No

FMU follows Contractor Mangement Procedure and advises Commercial Service

Provider and Facilities Coordinator of impending work.

18

Page 19: Campus Signage Manual

S I G N A G E R E Q U E S T F O R M S

1919

Page 20: Campus Signage Manual

OFFICE USE

ONLY

OFFICE USE

ONLY

Signage Request Form FMU085 Updated June 09

CAMPUS

City East City West Magill Mawson Lakes

Whyalla/Mt Gambier External

CONTACT DETAILS

Name .....................................................................

Contact Number ................................................

Area ........................................................................

Date Requested ..................................................

Due Date ...............................................................

Cost Centre ..........................................................

Authorisation Signature of Cost Centre

Manager ...............................................................(NB requests will not be processed without a cost centre)

LOCATION Building ............................................................................

Level ..................................................................................

Wall/Area ......................................................................... (Please attach map when possible)

BILLING

Manufacture $ .....................................

Installation $ .....................................

Total $ .....................................

Install Billed to: SS / Prop / Customer

External Invoice Y / N

Book Out Date ..........................................

Signature .........................................................................

Signage Description………………………………………………………………………………………………………………………………………

………………………………………………………………………………………………………………………………………

………………………………………………………………………………………………………….……………………………

………………………………………………………………………………………………………………………………………

………………………………………………………………………………………………………………………………………

………………………………………………………………………………………………………………………………………

………………………………………………………………………………………………………………………………………

………………………………………………………………………………………………………………………………………

………………………………………………………………………………………………………………………………………

………………………………………………………………………………………………………………………………………

……………………………………………………………………………………………………………………………………

Signage Details

OFFICE USE

ONLY

JOB NUMBER ...................................................

File Name ..........................................................

GENERAL SIGNAGE. - JOB SHEET(Please �ll ALL unshaded area)

20

Page 21: Campus Signage Manual

Room number Text on plate Door type Cost Cost Property School

Name .................................................................................. Ext’n ........................

Area / School ..........................................................................................................

Cost Centre Code ..................................................................................................

Order date .............................................. Due date .............................................

STANDARD DOOR PLATE JOB SHEET

* Old : 2 or 3 seperate plates joined to make one sign with blue or black text

* New : single plate with metallic charcoal text

Door Plate Request Form FMU 064

TOTAL

OFFICE USE

ONLY

OFFICE USE

ONLY

Job number .....................................................................

Location .............................................................................

Booked Out ..........................

Signed ..................................................................................

$ ............................................... (School)

$ ............................................... (Property

line1: ....................................................................................................................................................

line2: ....................................................................................................................................................

other: ....................................new or old

glass door door with window

solid door sliding door

............ ..............

OFFICE USE

ONLY

OFFICE USE

ONLY

current plate type*

line1: ....................................................................................................................................................

line2: ....................................................................................................................................................

other: ....................................new or old

glass door door with window

solid door sliding door

............ ..............

OFFICE USE

ONLY

OFFICE USE

ONLY

current plate type*

line1: ....................................................................................................................................................

line2: ....................................................................................................................................................

other: ....................................new or old

glass door door with window

solid door sliding door

............ ..............

OFFICE USE

ONLY

OFFICE USE

ONLY

current plate type*

line1: ....................................................................................................................................................

line2: ....................................................................................................................................................

other: ....................................new or old

glass door door with window

solid door sliding door

............ ..............

OFFICE USE

ONLY

OFFICE USE

ONLY

current plate type*

line1: ....................................................................................................................................................

line2: ....................................................................................................................................................

other: ....................................new or old

glass door door with window

solid door sliding door

............ ..............

OFFICE USE

ONLY

OFFICE USE

ONLY

current plate type*

21

Page 22: Campus Signage Manual

P e r m a n e n t S t a n d a r d C a m p u s S i g n a g e

T e c h n i c a l S p e c i fi c a t i o n

2222

Page 23: Campus Signage Manual

2323

Page 24: Campus Signage Manual

Technical Specifications

P-CM-01

Permanent Standard Campus Signage

Campus Map Type A

Wall Mounted

Frutiger

Prominent external location to be negotiated with andapproved by Property Unit

Fixed to A-Frame or wall using appropriate hidden fittings bynegotiation with Property Unit

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

Campus Map Type A

2424

Page 25: Campus Signage Manual

Technical Specifications

P-CM-05

Permanent Standard Campus Signage

Campus Map Type B

Bollard

Frutiger

At key/prominent campus entry points, exact location to benegotiated with and approved by Property Unit

Transfer facing. City West: Dulux RMA Gold UniSAspecial colour used for backing of Bollard sign.All other campuses use Reflex blue for backing of sign.

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

3mm mild steel plates seam welded atedges and paint finished Reflex Blue

3mm naturalanodised aluminiumface panels,pin fixed proud

150mm diam.Nominalbore CHS weldedto internal cleats

Logo-Cast ColourDeep Blue (050)to match reflex blue

Anodised Aluminium

Campus Map Type B

2525

Page 26: Campus Signage Manual

2626

Page 27: Campus Signage Manual

Technical Specifications

P-SS-05

Permanent Standard Campus Signage

Campus Street Sign Type A

Long Flag

Frutiger. Size shall be dependant upon number of text lines on flag,i.e 1 line-70mm, 2 & 3 lines-40mm. Upper/lower in all instances.

At key directional locations

Destination: The street signs used to show the distance betweenAustralia and other countries is to be similar to the Oslo sign.The countries shape in silver and a red dot for the capital.The country name in reflex blue frutiger medium and the distancein reflex blue frutiger small all centered.

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

900mm

180mm

60mm 840mm

40mm

40mm

70mm

40mm

Campus CentralSecurity

70mm

Campus CentralCafeteria40mm

40mm BuildingA

40mm

70mmLibrary40mm Building

C40mm

City West, City East, MawsonLakes, Magill and Whyallastreet signs:Galvanised poles and alloy signclamps.The plates have a white vinylbackground with reflex bluelettering.

The sign itself can be purchasedfrom Heatpac, and they alsosupply all the clamps and boltsto fit.

Campus Street Sign Type A

2727

Page 28: Campus Signage Manual

Technical Specifications

P-SS-01

Permanent Standard Campus Signage

Campus Street Sign Type B

Short Flag

Frutiger. Size shall be dependant upon number of text lines on flag,i.e 1 line-70mm, 2 & 3 lines-40mm.

At key directional locations

Destination: The street signs used to show the distance betweenAustralia and other countries is to be similar to the Oslo sign.The countries shape in Reflex blue and a red dot for the capital.The country name in reflex blue frutiger medium and the distancein reflex blue frutiger small all centered. On long flag.

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

750mm

City West, City East, MawsonLakes, Magill and Whyallastreet signs:Galvanised poles and alloy signclamps.The plates have a white vinylbackground with reflex bluelettering.

The sign itself can be purchasedfrom Heatpac, and they alsosupply all the clamps and boltsto fit.

60mm 690mm

70mm

70mm

70mm180mm

180mm 40mm

40mm

40mm 40mm

40mm

180mm50mm

40mm

Campus Street Sign Type B

2828

Page 29: Campus Signage Manual

2929

Page 30: Campus Signage Manual

Technical Specifications

P-DB-01

Permanent Standard Campus Signage

Directory Board Type A

Building Directory Board

Frutiger / charcoal

Prominent location in main ground floor entries of each building

Keep a zone of 2m min clear around each sign.Peoples names and titles are not to appear on this directory board

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

Radius = 1600mmHeight of panel = 1300mm

550mm

20mm20mm

C

D

E

F

A

B

C

D

E

F

A

G

H

B

I

18 mm thick HMR, MDF panel 1800mm H x 700mmW finished in satin, automotive acrylic lacquer tomatch PMS 285.

2mm thick, satin natural anodised aluminium panel1400mm H x 650mm W rolled to specified radius andadhesive fixed with V.H.B. double sided tape andsilicon adhesive.

1.2mm thick zinc anneal panel, finished in metallicsilver automotive acrylic lacquer, with radius to faceand double edge returns to both vertical sides.Size 1300mm H x 550mm W. Key hole fix to faceof panel A.

16mm thick MDF split batton, screw & glue fixed torear of panel A.

16mm thick MDF split batton, mechanically fixed towall with suitable fixings, to suit wall type.

16mm thick MDF spacer strip fixed to rear of panel A

90mm high, UniSA logo cut in 1.6mm thick, No. 4,

satin finish stainless steel and adhesive fixed topanel A, where shown.

Lettering in corporate Frutiger font as shownFrutiger font as shown Building Name 40mm

high lettering. 1.6mm thick, No. 4,

Metallic Charcoal lettering in corporate Frutiger font.Size and justification as per 1:1 layout herewith.

G

H

I

D

A

CB

UniSA

Directory Board Type A

satin finish stainless steel and adhesive fixed topanel A, where shown.

3030

Page 31: Campus Signage Manual

Technical Specifications

P-DB-02

Permanent Standard Campus Signage

Directory Board Type A - Free Standing

Directory Board

Frutiger 65 / Metalic Charcoal

Prominent location

Keep a zone of 2m min clear around each sign.Peoples names and titles are not to appear on this directory board

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

Catherine Helen Spence(CS) Building

LibraryDIRECTORY

Bolted to ground

660mm

460mmBehind Panal

1750mm(1745mm Skin)1645mm x 575mm

1545mm Backing(1645mm Enclosed)

75mm

Double Sided

Directory Board Type A - Free Standing

3131

Page 32: Campus Signage Manual

Technical Specifications

P-DB-05

Permanent Standard Campus Signage

Directory Board Type B

Floor Directory Board 1

Frutiger

Prominent location

Keep a zone of 2m min clear around each sign.Peoples names and titles are not to appear on this directory board

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

A

D

B

1100mm

20mm

20mm

Radius = 3200mm Height of panel= 450mm

C

C

A

B

C

D

E

F

ROOM

R2 - 01-R2 - 12

2Academics' Offices

Administrative Suite

Computer Pool

CRC for WaterQuality & Treatment

Head of School

Microelectronics Centre

Reception

Research Laboratory: Analysis & Sensors & Electrochemistry

Teaching Laboratories: Analytical Chemistry Physical Chemistry Transfer Operations

Tutorial Room

School of Chemical Technology

R2 - 50-R2 - 62

R2 - 41

R2 - 42

R2 - 41B

R2 - 41C

R2 - 47

R2 - 43

R2 - 45

R2 - 31R2 - 29R2 - 38

R2 - 36

ROOM

Exit - Link to Building Q

Lifts to Level 2

Postgraduate Students Room

Stairs to Level 2

Teaching Laboratories: Inorganic Chemistry Organic Chemistry

R2 - 48

R2 - 55R2 - 55

ROOM

Teaching Laboratories: First Year Chemistry

A

K

BJ

G

I

H Bonython Jubilee Building

D

E

F

G

H

K

18 mm thick HMR, MDF panel 875mm H x1550mm W finished in satin,automotive acrylic lacquer to match PMS 285.2mm thick, satin natural anodised aluminiumpanel 550mm H x 1200mm Wrolled to specified radius and adhesive fixedwith V.H.B. double sided tape and siliconadhesive.1.2mm thick zinc anneal panel, finished inmetallic silver automotive acrylic lacquer,with radius to face and double edge returnsto both vertical sides.Size 450mm H x 1100mm W.Key hole fix to face of panel A.16mm thick MDF split batton, screw & gluefixed to rear of panel A.16mm thick MDF split batton, mechanicallyfixed to wall with suitable fixings,to suit wall type.16mm thick MDF spacer strip fixed to rear ofpanel A125mm high, UniSA logo cut in 1.6mm thick,No. 4, satin finishstainless steel and adhesive fixed topanel A, where shown.60mm high ‘Building name‘ cut in 1.6mmthick No. 4 stainless steel adhesive fixed topanel A, where shown, upper and lower case.207mm high 'Floor No.’ cut in 1.6mm thickNo. 4 stainless steel, adhesive fixed to panelA, where shown.Metallic Charcoal lettering incorporate Fruitiger font.Size and justification as per 1:1 layoutherewith.1.6mm thick satin, natural anodisedaluminium panel 420mm H x 300mm Wadhesive fixed 6mm proud of panel A,where shown.

I

J

Directory Board Type B

3232

Page 33: Campus Signage Manual

Technical Specifications

P-DB-10

Permanent Standard Campus Signage

Directory Board Type C

Floor Directory Board 1

Frutiger

Prominent location

Keep a zone of 2m min clear around each sign.Peoples names and titles are not to appear on this directory board

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

A

B

C

D

E

F

G

H

18 mm thick HMR, MDF panel 875mm H x1550mm W finished in satin,automotive acrylic lacquer to match PMS 285.2mm thick, satin natural anodised aluminiumpanel 550mm H x 1200mm Wrolled to specified radius and adhesive fixedwith V.H.B. double sided tape and siliconadhesive.1.2mm thick zinc anneal panel, finished inmetallic silver automotive acrylic lacquer,with radius to face and double edge returnsto both vertical sides.Size 450mm H x 1100mm W.Key hole fix to face of panel A.16mm thick MDF split batton, screw & gluefixed to rear of panel A.16mm thick MDF split batton, mechanicallyfixed to wall with suitable fixings,to suit wall type.16mm thick MDF spacer strip fixed to rear ofpanel A125mm high, UniSA logo cut in 1.6mm thick,No. 4, satin finishstainless steel and adhesive fixed topanel A, where shown.60mm high ‘Building name‘ cut in 1.6mmthick No. 4 stainless steel adhesive fixed topanel A, where shown, upper and lower case.207mm high 'Floor No. cut in 1.6mm thickNo. 4 stainless steel, adhesive fixed to panelA, where shown.Metallic Charcoal lettering incorporate Fruitiger font.Size and justification as per 1:1 layoutherewith.

I

J

Directory Board Type C

D

B

470mm

20mm

20mmHeight of panel= 450mm

C

C

A

University of South Australia

School of Chemical Technology

R2 - 48

R2 - 55R2 - 55

ROOM

BJ

GD

E

F

H BUILDING R

Academics' Offices

Administrative Suite

Computer Pool

CRC for WaterQuality & Treatment

Head of School

Microelectronics Centre

Reception

Research Laboratory: Analysis & Sensors & Electrochemistry

Teaching Laboratories: Analytical Chemistry Physical Chemistry Transfer Operations

Tutorial Room

Exit - Link to Building Q

Lifts to Level 2

Postgraduate Students Room

Stairs to Level 2

Teaching Laboratories: Inorganic Chemistry Organic Chemistry

R2 - 50-R2 - 62

R2 - 41

R2 - 42

R2 - 41B

R2 - 41C

R2 - 47

R2 - 43

R2 - 45

R2 - 31R2 - 29R2 - 38

R2 - 36

ROOM

3333

Page 34: Campus Signage Manual

20mm

The space between the extrusion on the twosides and the bottom will need to be far enoughapart to fit 3xA4 transparencies.

Clear plastic covering to hold the transparenciesin place, needs to fit tight to the curve.

20mm20mm 100mm

H channel plastic extrusion,clear acrylic slides into grooves

70x85mmsilver logo

30mm Frutiger

800mm

Clear Plastic Extrusion withsilver vinyl on the top, fixedwith double sided tape

natural anodisedaluminium backing

Space Blue backing board

180mm300mm

100mm 700mm

Technical Specifications

P-DB-15

Permanent Standard Campus Signage

Directory Board Type D

Staff Directory Board

Frutiger

Adjacent to Directory Boards Types A-C (note 2m clear zone),otherwise to be approved by Property Unit

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

UniSA40mm Frutiger

(H202 Section 1.5mm)

Font for the Staff transparencies to be frutiger or the closest font to that. Approximately 13-14 names should be included on each A4 transparency.

Directory Board Type D

3434

Page 35: Campus Signage Manual

Technical Specifications

P-DB-17

Permanent Standard Campus Signage

Directory Board Type F

Floor Directory Board

Frutiger / charcoal

Prominent location in main ground floor entries of each building

(Up-side down large FA sign)

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

500mm

1.0mm Natural Ancodised Facefixed with double sided tape

Backing board is powder coated to matchReflex Blue using courtaulds Colour space Blue Gloss MJ008A

UniSA

80ish mm20 mm

450mm

50mm50mm

Level 1

20mm gap from backingboard on each side

Back plate is a double sidedcurved Galvanisedenvelope 20mm depth atends, 80ish depth at centre

Cathine Helen SpenceBuilding

Concealed Fittings to be used that suit surface application

Directory Board Type F

3535

Page 36: Campus Signage Manual

D I R E C T O R Y I D E N T I F I C A T I O N S I G N S

3636

Page 37: Campus Signage Manual

Technical Specifications

P-BI-01

Permanent Standard Campus Signage

Building Identification Type A

Alpha Sign

Frutiger. metallic colour Charcoal vinyl (027)

Prominent external location on main facade of building exactlocation to be negotiated with and approved by Property UnitSign to be 600x600x20mm natural anodised

Concealed fixings to be used that suit surface application.

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

600mm

320mm

600mm

90mm

40mm

120mm

40mm

Building Identification Type A

3737

Page 38: Campus Signage Manual

Technical Specifications

3mm thickStainless Steel satin finish

P-BI-05

Permanent Standard Campus Signage

Building Identification Type B

Name on Building

Frutiger 75. Font size shall be determined through consultationwith customer and Property/Services Units. Usually 110mm

Prominent external location on main facade of building exactlocation to be negotiated with and approved by Property Unit

Background of lettering should provide suitable contrast forease of reading. Direction should be sought from Property Unitif contrast is unsuitable.

Concealed Fixings to be used that suit surface application.

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

CENTENARY BUILDING

Building Identification Type B

3838

Page 39: Campus Signage Manual

Technical Specifications

3100mm

2000mm

100mm

200mm

800mm

Logo- to match reflex blue

Anodised Aluminium

Text-charcoal

70mm

150mm diameternominal boreCHS 3mm thick

500mm diameterconcrete pier

P-BI-10

Permanent Standard Campus Signage

Building Identification Type C

Stand Alone Bollard Sign

Frutiger. Charcoal. Font size shall be determinedon application

Prominent external location adjacent main entrance/forecourtto building, exact location to be approved by Property Unit

UniSA logo shall match Reflex Blue Standard.Integrity of logo and text shall adhere to standardsspecified in Your Guide to our Visual Identity-UniSA Design Standards.Text information and layout shall be determined in consultation withcustomer and Property Services Units upon application.

Refer diagram above

3mm mild steel plates seam welded atedges and paint finished Reflex Blue

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

3mm natural anodisedaluminium face panels,pin fixed proud 150mm diam.

Nominal bore CHSwelded to internal cleats160 Kilos weight

Building Identification Type C

3939

Page 40: Campus Signage Manual

4040

Page 41: Campus Signage Manual

Technical Specifications

P-CI-01

Permanent Standard Campus Signage

Corporate Identification Sign Type A

Wall Mounted

Frutiger

Prominent wall location adjacent toCorporate Area key entry point

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

1800

mm

Text-colour - Metallic Charcoal

650mm50mm

63mm

25mm from main frame

236.5mm50mm

50mm

265mm

80mm

Anodised Aluminium (1.0)

Logo Colourto match reflex blue

C A M RCentre

for AdvancedManufacturing

Research

40mm 40mm

Curved panel fixedproud of back panel

297mm

325mm 325mm

Centred

Corporate Identification Sign Type A

4141

Page 42: Campus Signage Manual

Technical Specifications

P-CI-05

Permanent Standard Campus Signage

Corporate Identification Sign Type B

Stand Alone Bollard Sign

Frutiger

At key entry point to Corporate Area

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

Technical Drawing not currently available for this sign type

Corporate Identification Sign Type B

4242

Page 43: Campus Signage Manual

������������� ��������

�������

������������������������������

������������������������������!���

"������#$����%��������

��������*+;<��� ��;�������>���

��������?�������@�Q�������"�������;X��������$����%����Z

���������������� �����

������������������

���������

����������

���������������������

���������

������������

��!����"����#

��Q���[��������������������

\���������#��@���

������������������������������!���

������������� ���������������� ���University of

South Australia������������� ���

������������ ���University of

South Australia

43

Page 44: Campus Signage Manual

������������� ��������

������*

������������������������������

���������������������������������������

]Z*��������������

��������*+;<��� ��;������������

^�����������%���������������������%�����������

���������������� �����

������������������

���������

����������

���������������������

���������

������������

��!����"����#

��Q���[��������������������

\��[�����������_��������%������`�����

���������������������������������������

������������� ��� ������������� ���University of

South Australia

44

Page 45: Campus Signage Manual

4545

Page 46: Campus Signage Manual

Schoolof Nursing &Midwifery

Technical Specifications

400mm

700mm

120mm

500mm

50mm 50mm

50mm

50mm

350mm

50mm

20mm gap from backingboard on each side

Back plate is a double sidedcurved Galvanisedenvelope. 20mm depth atends, 80ish mm depth at centre

Type cap height to be aminimum of 18mm in Charcoalmetallic upper and lower case

Face printed on removable adhesive clear vinyl (502mm x 352mm)

1.0mm Natural Anodised Facefixed with double sided tape

Backing board is powder coated to matchReflex Blue using courtaulds Colour SpaceBlue Gloss MJ008A

Logo Colourto match Reflex Blue

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-FA-01

Permanent Standard Campus Signage

Functional Area ID Sign Type A

Small

Frutiger.18mm min.Metallic Charcoal

Prominent wall location at key entry point to division/school/centre/institute/unit.

Integrity of logo and text shall adhere to standards specified inYour Guide to our Visual Identity-UniSA Design Standards.

Concealed Fittings to be used that suit surface application

50mm

20mm

80mm

Functional Area ID Sign Type A

4646

Page 47: Campus Signage Manual

Schoolof Nursing &Midwifery

Technical Specifications

500mm

900mm

180mm

700mm

80mm 50mm

50mm

80mm

450mm

50mm

20mm gap from backingboard on each side

Back plate is a double sidedcurved Galvanisedenvelope. 20mm depth atends, 80ish mm depth at centre

Type cap height to be aminimum of 18mm in Charcoalmetallic upper and lower case

Face printed on removable adhesive clear vinyl (702mm x 452mm)

1.0mm Natural Anodised Facefixed with double sided tape

Backing board is powder coated to matchReflex Blue using courtaulds Colour SpaceBlue Gloss MJ008A

Logo Colourto match Reflex Blue

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-FA-01

Permanent Standard Campus Signage

Functional Area ID Sign Type B

Large

Frutiger.30mm min.Metallic Charcoal

Prominent wall location at key entry point to division/school/centre/institute/unit.

Integrity of logo and text shall adhere to standards specified inYour Guide to our Visual Identity-UniSA Design Standards.

Concealed Fittings to be used that suit surface application

50mm

20mm

80mm

Functional Area ID Sign Type B

4747

Page 48: Campus Signage Manual

4848

Page 49: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-22

Permanent Standard Campus Signage

Blade Amenity

Priority Access (Computer)

Frutiger / 22mm / Reflex Blue 754

Priority Access Computer. Bottom edge of sign ofapproximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

50mm

28mm

140mm

200mm

Priority Access (Computer)

4949

Page 50: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-81

Permanent Standard Campus Signage

Blade Amenity

Access / Female Toilet

Frutiger / 16mm / Reflex Blue 754

Above Entrance door to Access Female Toilet Facilities. Bottom edge ofsign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Access Female Toilets

5050

Page 51: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-89

Permanent Standard Campus Signage

Blade Amenity

Access / Male Toilet

Frutiger / 16mm / Reflex Blue 754

Above Entrance door to Access Male Toilet Facilities. Bottom edge ofsign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Access / male Toilet

5151

Page 52: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-83

Permanent Standard Campus Signage

Blade Amenity

Access Toilet / Baby Change Room

Frutiger / 15mm / Reflex Blue 754

Above Entrance door to Change Room Facilities. Bottom edge ofsign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Access Toilet / Baby Change Room

5252

Page 53: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-85

Permanent Standard Campus Signage

Blade Amenity

AccessToilets

Frutiger / 16mm / Reflex Blue 754

Above Entrance door to Access Toilet Facilities. Bottom edge ofsign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Access Toilets

5353

Page 54: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-96

Permanent Standard Campus Signage

Blade Amenity

Access / Toilet

Frutiger / 16mm / Reflex Blue 754

Above Entrance door to Access Female / Male Toilet Facilities. Bottom edge ofsign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Access / Toilet

5454

Page 55: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-84

Permanent Standard Campus Signage

Blade Amenity

Access / Toilet / Shower

Frutiger / 16mm / Reflex Blue 754

Above Entrance door to Access Toilet / Shower Facilities. Bottom edge ofsign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Access / Toilet / Shower

5555

Page 56: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-50

Permanent Standard Campus Signage

Blade Amenity

Security

Frutiger / 22mm / blue (006) Calplus in vinyl

Above entrance door to Security Office. Bottom edge ofsign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Security

5656

Page 57: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-55

Permanent Standard Campus Signage

Blade Amenity

Security Phone

Frutiger / 22mm / blue (006) Calplus in vinyl

Above Security phone. Bottom edge ofsign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Security Phone

5757

Page 58: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-91

Permanent Standard Campus Signage

Blade Amenity

Study Room

Frutiger 30mm / 702 Burgundy Red

Above entrance door to Study RoomBottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Study Room

5858

Page 59: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-34

Permanent Standard Campus Signage

Blade Amenity

Staff Room

Frutiger 65 / 20mm / 702 Burgundy Red

Above entrance door to Staff Room.Bottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

112mm108mm

155mm65mm

210mm

52mm

50mm

28mm

Staff Room

5959

Page 60: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-90

Permanent Standard Campus Signage

Blade Amenity

Seminar Room

Frutiger 65 / 20mm / 702 Burgundy Red

Above entrance door to Seminar Room.Bottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

112mm108mm

155mm65mm

210mm

52mm

50mm

28mm

Seminar Room

6060

Page 61: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-92

Permanent Standard Campus Signage

Blade Amenity

Quiet Study Area

Frutiger 30mm / 702 Burgundy Red

Above Quiet Study AreaBottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Quiet Study Area

6161

Page 62: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-94

Permanent Standard Campus Signage

Blade Amenity

Books 000-###

Frutiger 30mm / 702 Burgundy Red

In appropriate location.Bottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Books 000-###

######

6262

Page 63: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-93

Permanent Standard Campus Signage

Blade Amenity

Journals

Frutiger 30mm / 702 Burgundy Red

Above entrance door to JournalsBottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Journals

6363

Page 64: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-95

Permanent Standard Campus Signage

Blade Amenity

New Books & Journals

Frutiger 30mm / 702 Burgundy Red

Above entrance door to New Books & Journals.Bottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

New Books & Journals

6464

Page 65: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-33

Permanent Standard Campus Signage

Blade Amenity

Meeting Room

Frutiger 65 / 17mm / 702 Burgundy Red

Above entrance door to Meeting RoomBottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

112mm108mm

155mm65mm

210mm

52mm

50mm

28mm

Meeting Room

6565

Page 66: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-30

Permanent Standard Campus Signage

Blade Amenity

Lecture Theatre

Frutiger / 20mm / 702 PF Burgundy Red (Awery)

Above entrance door to Lecture Theatre.Bottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

98mm112mm

98mm112mm

173mm

69mm

50mm

28mm

Lecture Theatre

6666

Page 67: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-15

Permanent Standard Campus Signage

Blade Amenity

Computer Room

Frutiger / 20mm / 702 PF Burgundy Vinyl (Avery)

Above entrance door to computer room.Bottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

98mm112mm

98mm112mm

173mm

69mm

50mm

28mm

Computer Room

6767

Page 68: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-16

Permanent Standard Campus Signage

Blade Amenity

Printer Pool

Frutiger / 25mm / Burgundy 702 (Avery)

Above entrance door to above Printer Pool. Bottom edge of sign ofapproximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Printer Pool

6868

Page 69: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-13

Permanent Standard Campus Signage

Blade Amenity

Computer Pool

Frutiger / 20mm /Burgundy 702

Above entrance door to computer room.Bottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

98mm112mm

98mm112mm

173mm

69mm

50mm

28mm

Computer Pool

6969

Page 70: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-14

Permanent Standard Campus Signage

Blade Amenity

Computer Barn

Frutiger / 20mm / Burgundy 702

Above entrance door to computer barn.Bottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

112mm108mm

155mm65mm

210mm

52mm

50mm

28mm

Computer Barn

7070

Page 71: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-32

Permanent Standard Campus Signage

Blade Amenity

Augmented Hearing Lecture Theatre

Frutiger 65 / 20mm & 12mm / 702 PF Burgundy Red & Reflex Blue 754

Above entrance door to Lecture Theatre.Bottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

112mm108mm

155mm65mm

210mm

52mm

50mm

28mm

Augmented Hearing Lecture Theatre

7171

Page 72: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-18

Permanent Standard Campus Signage

Blade Amenity

Adaptive Technology Suit

Frutiger / 17mm / Burgundy 702

Above entrance door. Bottom edge of sign ofapproximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

108mm

210mm

50mm

28mm

65mm 155mm

112mm

52mm

Adaptive Technology

7272

Page 73: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-30

Permanent Standard Campus Signage

Blade Amenity

Tutorial Room

Frutiger / 20mm / 702 PF Burgundy Red (Awery)

Above entrance door to Tutorial Room.Bottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

98mm112mm

98mm112mm

173mm

69mm

50mm

28mm

Tutorial Room

7373

Page 74: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-70

Permanent Standard Campus Signage

Blade Amenity

Phone

Frutiger / 30mm / cast colour Royal Blue (006) in vinyl

Above Public Telephone. Bottom edge ofsign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Phone

7474

Page 75: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-86

Permanent Standard Campus Signage

Blade Amenity

Toilets

Frutiger / 22mm / cast colour Copenhagen blue

Above Entrance to Toilet Facilities. Bottom edge ofsign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Toilets

7575

Page 76: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-75

Permanent Standard Campus Signage

Blade Amenity

Male Toilet

Frutiger / 22mm / cast colour Copenhagen blue

Above Entrance to Male Toilet Facilities. Bottom edge ofsign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Male Toilet

7676

Page 77: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-80

Permanent Standard Campus Signage

Blade Amenity

Female Toilet

Frutiger / 22mm / cast colour Copenhagen blue

Above Entrance to Female Toilet Facilities. Bottom edge ofsign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Female Toilet

7777

Page 78: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-87

Permanent Standard Campus Signage

Blade Amenity

Female / Male Toilet

Frutiger / 22mm / cast colour Copenhagen blue

Above Entrance to Female / Male Toilet Facilities. Bottom edge ofsign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Female / Male Toilet

7878

Page 79: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-60

Permanent Standard Campus Signage

Blade Amenity

Shower

Frutiger / 25mm / cast colour Copenhagen blue (756) in vinyl

Above entrance door to Shower. Bottom edge ofsign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

50mm

28mm

98mm112mm

98mm112mm

173mm

69mm

Shower

7979

Page 80: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-88

Permanent Standard Campus Signage

Blade Amenity

Female / Male Toilets and Showers

Frutiger / 22mm / cast colour Copenhagen blue

Above Entrance to Female / Male Toilets and Showers. Bottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Female / Male Toilets and Showers

8080

Page 81: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-76

Permanent Standard Campus Signage

Blade Amenity

Male Toilet / Showers

Frutiger / 22mm / cast colour Copenhagen blue

Above Entrance to Male Toilet / Showers. Bottom edge ofsign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Male Toilets / Shower

8181

Page 82: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-77

Permanent Standard Campus Signage

Blade Amenity

Female Toilet / Showers

Frutiger / 22mm / cast colour Copenhagen blue

Above Entrance to Female Toilet / Showers. Bottom edge ofsign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Female Toilets / Shower

8282

Page 83: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-81

Permanent Standard Campus Signage

Blade Amenity

Change Room

Frutiger / 20mm / Copenhagen Blue 91587

Above Entrance door to Change Room Facilities. Bottom edge ofsign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Change Room

8383

Page 84: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-40

Permanent Standard Campus Signage

Blade Amenity

Mail Room

Frutiger / 22mm / copenhagen blue (756) Cast colour in vinyl

Above entrance door to Mail Room. Bottom edge of sign ofapproximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Mail Room

8484

Page 85: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign çlassification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-35

Permanent Standard Campus Signage

Blade Amenity

Lift

Frutiger / 30mm / copenhagen blue (756) Cast colour in vinyl

Above Lift Car entrance. Bottom edge of sign of approximately2200mm above floor level

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape. The graphic for this blade sign shall conform toAS2899.1 Public Information Symbol Signs Part 1-GeneralInformation Signs, Standard Symbol Sign:120

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

145mm145mm

Lift

8585

Page 86: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-65

Permanent Standard Campus Signage

Blade Amenity

Stairs

Frutiger / 30mm / cast colour Copenhagen blue (756) in vinyl

Above entrance to Stairs. Bottom edge ofsign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

50mm

28mm

98mm112mm

98mm112mm

173mm

69mm

Stairs

8686

Page 87: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-20

Permanent Standard Campus Signage

Blade Amenity

First Aid

Frutiger / 22mm / green (005) Calplus in vinyl

Above entrance door to First Aid. Bottom edge of sign ofapproximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

100mm

100mm

First Aid

8787

Page 88: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-10

Permanent Standard Campus Signage

Blade Amenity

Cafeteria

Frutiger / 40mm / Turquoise (731HP) Avery

Above entrance door to cafeteria. Bottom edge of sign ofapproximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

98mm112mm

98mm112mm

173mm

69mm

50mm

28mm

8888

Page 89: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-05

Permanent Standard Campus Signage

Blade Amenity

Bar

Frutiger / 40mm / Turquoise (731 HP) Avery

Above entrance door to bar. Bottom edge of sign of approximately2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

112mm108mm

155mm65mm

210mm

52mm

50mm

28mm

Bar

8989

Page 90: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-19

Permanent Standard Campus Signage

Blade Amenity

Book Returns

Frutiger 65 / 15mm / Turquoise 731

In appropriate location. Bottom edge of sign ofapproximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

108mm

210mm

50mm

28mm

65mm 155mm

112mm

52mm

Book Returns

9090

Page 91: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-21

Permanent Standard Campus Signage

Blade Amenity

Multi Access Suite

Frutiger / 18mm / Turquoise 731

Above entrance door to Multi Access Suite. Bottom edge of sign ofapproximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

140mm

200mm

50mm

28mm

Multi Access Suite

9191

Page 92: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-17

Permanent Standard Campus Signage

Blade Amenity

Student Common Room

Frutiger 65 / 15mm / Turquoise 731 (Avery)

Above entrance door to Student Common Room. Bottom edge of sign ofapproximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

112mm108mm

155mm65mm

210mm

52mm

50mm

28mm

Student Common Room

9292

Page 93: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-25

Permanent Standard Campus Signage

Blade Amenity

International Students Room

Frutiger / 18mm / Turquoise (731 HP) Avery

Above entrance door to International Students Room.Bottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

98mm112mm

98mm112mm

173mm

69mm

50mm

28mm

International Students Room

9393

Page 94: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-45

Permanent Standard Campus Signage

Blade Amenity

Prayer Room

Frutiger / 22mm / Turquoise (731) Avery

Above entrance door to Prayer Room.Bottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

98mm112mm

98mm112mm

173mm

69mm

50mm

28mm

Prayer Room

9494

Page 95: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-46

Permanent Standard Campus Signage

Blade Amenity

Male Prayer Room

Frutiger / 13mm / Turquoise (731)

Above entrance door to Prayer Room.Bottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

112mm108mm

155mm65mm

210mm

52mm

50mm

28mm

Male Prayer Room

9595

Page 96: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-47

Permanent Standard Campus Signage

Blade Amenity

Female Prayer Room

Frutiger 65 / 13mm / Turquoise (731)

Above entrance door to Prayer Room.Bottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

112mm108mm

155mm65mm

210mm

52mm

50mm

28mm

Female Prayer Room

9696

Page 97: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-BA-48

Permanent Standard Campus Signage

Blade Amenity

Chaplain

Frutiger 65 / 20mm / Turquoise (731)

Above entrance door.Bottom edge of sign of approximately 2200mm above floor level.

The backing and top plate are cut out from 1.0mm thick naturalanodised aluminium. The two backing plates are glued togetherwith liquid nails. The top plates are stuck together using 3Mdouble sided tape.

The cable fittings (CAB14SC) are to be installed at 50mm from thetop and the bottom of the backing plates on the straight edge.

145mm

292.5mm

65mm

7.5mm

70mm15mm 60mm

32.50mm

7.5mm 130mm 7.5mm

32.50mm10mm

112mm108mm

155mm65mm

210mm

52mm

50mm

28mm

Chaplain

9797

Page 98: Campus Signage Manual

D O O R S I G N S

9898

Page 99: Campus Signage Manual

City West, City East and Whyalla Campus-Natural Anodised plateswith black helvetica lettering cast colour Black (008) withblack components.

Magill-White powder coated plates with blue Helveticalettering cast colour Reflex Blue and white components.

Mawson Lakes-White powder coated plates with Palatinoblue lettering cast colour Reflex Blue and whitecomponents.

Underdale-White powder coated plates with blue Helveticalettering cast colour Reflex Blue and white components.

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-DS-01

Permanent Standard Campus Signage

Door Sign Type A

Two Part Door Sign

Refer Details above 25mm text

On door leafBottom edge of sign of approximately 1500mm above floor level.

Concealed fixings.

merlin

450mmx40mm

A1-03A Lecture Theatre

joiner

25mm text 25mm text

Door Sign Type A

150 x 140mm

9999

Page 100: Campus Signage Manual

Dr Anna Ciccarelli300mm

Technical Specifications

P-DS-25

Permanent Standard Campus Signage

Staff Pigeon Hole Names Sign

Staff Pigeon Hole Name

Helvetica Extended Medium (009) and compressed to 79%.Cast Colour Black (008)

On pigeon hole unit under each person’s pigeon hole

Natural Anodised plate with black end clips.Signs mainly used at City West

Siliconed/double sided tape

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

20mm

Staff Pigeon Hole Names Sign

100100

Page 101: Campus Signage Manual

Dr Anna Ciccarelli300mm

Technical Specifications

P-DS-26

Permanent Standard Campus Signage

Staff Pigeon Hole Names Sign Type B

New Style Door Palte - DOuble Line

Frutiger 65 / 12mm / Metallic Charcoal

Centred on pigeon hole door

Natural anodized aluminium plate

Concealed fixings, attached to pigeon hole with 3M double-sided

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

30mm

Staff Pigeon Hole Names Sign Type B

101101

Page 102: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-DS-07

Permanent Standard Campus Signage

Door Sign Type D

New Style Door Plate - Double Line

Frutiger 65 / 12mm / Metallic Charcoal

On door leafBottom edge of sign of approximately 1500mm above floor level.

Concealed fixings.

A1 -03A

Text Height: 12mm; Font: Frutiger 65; Colour: Matallic Charcoal

600mm

30mm 30mm

50mm

1 Part Door Plates, 2 lines of text

Natural anadized aluminium plate

Mr Joe BloggsLecturer

(Text to be centered top to bottom)

Door Sign Type D

102102

Page 103: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-DS-06

Permanent Standard Campus Signage

Door Sign Type C

New Style Door Plate - Single Line

Refer Details above 25mm text

On door leafBottom edge of sign of approximately 1500mm above floor level.

Concealed fixings.

A1 -03A Lecture Theatre

Text Height: 25mm; Font: Frutiger 65; Colour: Matallic Charcoal

600mm

30mm 30mm

50mm

1 Part Door Plates, Single line of text

Natural anadized aluminium plate

Door Sign Type C

103103

Page 104: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-DS-05

Permanent Standard Campus Signage

Door Sign Type B

Three Part Door Sign

Refer Detail above 12mm text

On door leafBottom edge of sign of approximately 1500mm above floor level.

Concealed fixings.

merlin twin

450mmx20mm

joiner

150mmx40mm

City West, City East and Whyalla Campus-Natural Anodised plateswith black helvetica lettering cast colour Black (008) withblack components.

Magill-White powder coated plates with blue Helveticalettering cast colour Reflex Blue and white components.

Mawson Lakes-White powder coated plates with Palatinoblue lettering cast colour Reflex Blue and whitecomponents.

Underdale-White powder coated plates with blue Helveticalettering cast colour Reflex Blue and white components.

25mm text 12mm text

Door Sign Type B

104104

Page 105: Campus Signage Manual

Technical Specifications

P-DS-23

Permanent Standard Campus Signage

Name Plate

Reception/Counter Name Plate

Frutiger, 15mm upper/lower case. Metallic CharcoalLogo silver vinyl

Front counter, reception desk or office desk

Integrity of logo and text shall adhere to standards specified inYour Guide To Our Visual Identity-UniSA Design Standards.

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

Materials: Natural AnodisedAluminiumReflex Blue PerspexPieces placed together usingdouble sided tape

200mm

230mm

Name here

20mm

25mm

45mm

50mm 36mm

50mm

10mm

30mm

40mm

18mm

15mm

18mm

35mm

5mm

10m

m

50m

m50

mm

45

5mm

105105

Page 106: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-DS-10

Permanent Standard Campus Signage

Door Sign Type C

Access Toilet

Reflex Blue / White

On door leaf (centred)l.

Natural anodised plate

Siliconed/double sided tape

150mm

150mm

130mm

Door Sign Type C

106106

Page 107: Campus Signage Manual

Technical Specifications

P-DS-15

Permanent Standard Campus Signage

Door Sign Type D

Female Toilet

Copenhagen Blue

On door leaf (Centred)

Natural Anodised plate

Siliconed/double sided tape

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

120mm150mm

150mm

Door Sign Type D

107107

Page 108: Campus Signage Manual

Technical Specifications

P-DS-20

Permanent Standard Campus Signage

Door Sign Type E

Male Toilet

Copenhagen Blue

On door leaf (Centred)

Natural Anodised plate

Siliconed/double sided tape

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

120mm150mm

150mm

Door Sign Type E

108108

Page 109: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-DS-30

Permanent Standard Campus Signage

Frosted Vinyl Logos to Glazed Doors

OHS Uni-Logo Frosting

Standard University Logo

As per diagram

Frosted Vinyl direct-stick to door

Shield & Text Height 150mm

Type AGlazed Doors Between630mm & 830mm

Type BGlazed Doors Between830mm & 1010mm

Type CGlazed Doors Between

1010mm & 1280mm

Shield & Text Height 200mm Shield & Text Height 250mm

OHS Uni Logo Frosting for Glass Doors

Frosted Vinyl Logos to Glazed Doors

109109

Page 110: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-DS-09

Permanent Standard Campus Signage

Vinyl Door Text in Hawke Building

Hawke Building sign Type ID 7

Frutiger 45 / 38mm / Matt Black (Avery 721)

As per diagram

Vinyl direct-stick to door

A1 -03A

Text Height: 38mm; Font: Frutiger 45; Compression 90%; Character Spacing 4; Colour: Matt Black (Avery 721)

1750mm

Dr Anna CirrarelliPVC & Vice President: International and Development

The CrowleyReseach Room

20mm

87mm

Hawke Building sign Type ID 7

110110

Page 111: Campus Signage Manual

Technical Specifications

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

P-DS-08

Permanent Standard Campus Signage

Door Sign Type E

Hawke Building new Style Door Plate - Double Line

Frutiger 55 & 45 / 10 & 8mm / White

On door leafBottom edge of sign of approximately 1500mm above floor level.

Concealed fixings, attached to door with 3M double-side tape

A1 -03A

Text Height: 8 & 10mm; Font: Frutiger 55 & 45; Colour: White

600mm

Frutiger 55

50mm

Hawke Building 1 Part Door Plates, 2 lines of text

Door Plate is painted to match Dulux Luck

Dr Anna CirrarelliPVC & Vice President: International and Development

Frutiger 45

10mm text8mm numerals

Door Sign Type E

111111

Page 112: Campus Signage Manual

F I R E A N D S A F E T Y S I G N S

112112

Page 113: Campus Signage Manual

Technical Specifications

P-FS-01

Permanent Standard Campus Signage

Fire and Safety Sign Type A

Evacuation Sign

Frutiger

On Floor Directory Boards Type B-C on allocated panel

Orientation of evacuation map to suit location ofdirectory board so that north is in the correct direction

Film shall suit material surface to allow for easy replacementas required

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

Technical details not currently available for this sign type

Fire and Safety Sign Type A

113113

Page 114: Campus Signage Manual

C A R P A R K E N T R Y S I G N S

114114

Page 115: Campus Signage Manual

Top panel to be fixed using double sided tapeor anodised riveted

natural anodisedaluminium backing

Space Blue Powder coatedbacking board

Technical Specifications

P-CP-01

Permanent Standard Campus Signage

Car Park Entry Sign Type A

Stand Alone Bollard Type

Frutiger

At key carpark entry points

Only include those items/codes on the sign from the legend ofAllocated Parking For, which are applicable to the actual carpark

Hidden fittings for placement of two sheets. Poles are 2 metresin length with 1 metre enveloped between sheets.

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

100mm

20mm

1100mm

120mm

150mm

1100mm

1100mm150mm70mm

150mm

20

00

mm

17

00

mm

280mm

70mm

80mm type

55mm type

Cast Colour Ochre/Red (289)

CalpusGreen (005)Brown (010)Purple (075)Blue (006)Cherry (029)Fire Red (504)Orange (003)

Car Park Entry Sign Type A

115115

Page 116: Campus Signage Manual

O T H E R S I G N S O F I N T E R E S T

116116

Page 117: Campus Signage Manual

Technical Specifications

P-AC-01

Permanent Standard Campus Signage

Acrylic Sign Type A

Frosted acrylic

Frutiger 65 / best fit / Metallic Charcoal

Mounted to the wall in location as discussed with customer

Size can be altered if required

Fixed using brushed aluminium CAB fixings, or double-sided tape

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

800mm

180mm

Wall Mounted Acrylic Sign Single Sided

Borrow Here

Aluminium Fixings

117117

Page 118: Campus Signage Manual

Technical Specifications

P-AC-02

Permanent Standard Campus Signage

Acrylic Sign Type B

Frosted acrylic

Frutiger 65 / best fit / Metallic Charcoal

Mounted to the wall in location as discussed with customer

Size can be altered if required

Fixed using brushed aluminium CAB fixings, or double-sided tape

Signage Reference Number

Sign Classification

Sign Type

Sign Style

Font Type/size/colour

Placement

Other Remarks

Fixing Method

800mm

180mm

Hanging Acrylic Sign Double Sided

Borrow Here

Aluminium Fixings

118118