carolyn atkins, kiranmayee kilaru, brian ramsey, mikhail gubarev, steve o’dell, will w. zhang....

31
Overview of Differential Deposition at NASA MSFC Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Upload: sharyl-price

Post on 18-Jan-2018

214 views

Category:

Documents


0 download

DESCRIPTION

 Introduction  Horizontal chamber  Vertical chamber  Summary, conclusion and future work

TRANSCRIPT

Page 1: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Overview of Differential Deposition at NASA MSFC

Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang.

AXRO 2015, Prague, Czech Republic, 8th December 2015

Page 2: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Presentation outline

Introduction Horizontal chamber Vertical chamber Summary, conclusion and future

work

Page 3: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Presentation outline

Introduction Horizontal chamber Vertical chamber Summary, conclusion and future

work

Page 4: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Introduction to Differential Deposition

Page 5: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

5. X-ray testing

Differential Deposition process loop

2. Correction profile and simulations

4. Metrology1. Metrology

3. Perform correction

Page 6: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Proof of concept

0 5 10 15 20 25 30

-0.5

-0.4

-0.3

-0.2

-0.1

0

0.1

0.2

0.3

desired profileprofile before correctionprofile after correctionsimulated profile

Axial position along mirror (mm)

Profi

le h

eigh

t (µ

m)

Slope improvement from 12 to 7 arcsec RMS

K.Kilaru et al, Optical Engineering 50(10), 106501 (October 2011)

Initial proof of concept was performed upon miniature optics intended for radio-nuclide imaging using an existing RF sputtering system.

Form Talysurf data demonstrated an improvement in slope from 12 to 7 arc-sec.

Accurate metrology was the limiting factor in this investigation.

RF sputtering chamberMedical imaging optics

Page 7: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Vertical Chamber• DC magnetron sputtering

source• Designed for segmented

glass optics and large diameter full shell optics.

Horizontal Chamber• DC magnetron sputtering

source• Designed for full shell

electroformed optics

Concept developmentFollowing on from the proof of concept investigation a grant was awarded to further the research to astronomical X-ray optics.

Page 8: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Presentation outline

Introduction Horizontal chamber

- research conducted by Dr. Kiranmayee Kilaru Vertical chamber Summary and conclusion

Page 9: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Horizontal Chamber

X-ray optic held in a rotating and translating collet

Mask

X-ray optic

Magnetron head

Horizontal differential deposition chamber

Magnetron head within the optic

• Developed for full shell electroformed optics.• The optic translates and rotates relative to a stationary

sputtering/magnetron head.• The rotation and translation are encoder to ensure accurate

positioning.• Maximum shell diameter and length: 0.25m and 0.6m

respectively.• 1 inch (25.4mm) diameter sputtering/magnetron head

Work performed by Dr Kiranmayee Kilaru

Page 10: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Metrology - VLTP

• Vertical Long Trace Profiler• 1 mm spatial interval• New 2D camera and

modified software• Established procedures to

obtain repeatability of <100 Angstroms

• Multiple measurements - 4 scans per meridian with 4 realignment scans

Page 11: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Initial experimentation: single meridian correction

0 20 40 60 80 100 120 140 160 180-2000

-1500

-1000

-500

0

500

1000

1500

mm

Ang

stro

ms

Profile pre- & post- correction

pre-correctionpost1-correctionpost2-correction

complete profile only higher-order frequencies0

1

2

3

4

5

6

7

8Calculated HPD

7.08

3.68

2.87

6.71

2.95

1.86

arc-

seco

nds

pre-correctionpost1-correctionpost2-correction

0 20 40 60 80 100 120 140 160 180-800

-600

-400

-200

0

200

400

600

800

mmA

ngst

rom

s

Higher-frequencies of profile

pre-correctionpost1-correctionpost2-correction

Initial experimentation was performed on single meridians from Con-X replicas.

These results demonstrate the successful application of Differential Deposition upon astronomical X-ray optics.

The HPD values are calculated solely from VLTP metrology data.

Page 12: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Correction of optics for X-ray testing

• Optical prescription: parabola-hyperbola, nominal 140mm diameter, 580mm in length.

• Correction applied to both the parabolic and hyperbolic sections of the shell.

• Correction was performed in 3 sections comprising of 3 meridians each. Each meridian was separated by 24°.

• The optic was measured at MSFC’s 100m long Stray Light Facility.

• The optic can be tip-tilted and translated to obtain the optimum focus.

• Before and after correction measurements were performed using both the Stray Light Facility and the VLTP.

Page 13: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Correction 1 – X-ray testing and metrology

• VLTP metrology pre and post coating estimated an improvement from 15.7arc-sec to 9.2arc-sec.

• A 5mm slit was used to perform this correction, which targeted all spatial frequencies and customised for each meridian. • X-ray testing

highlighted an improvement from 15.7arc-sec HPW to 10.7 arc-sec HPW.

• Upon analysis the discrepancy between the expected and actual values was caused by the overlap region

Page 14: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Correction 2 – metrology

0 100 200-100

-50

0

50

100Slope

[mm]

[mic

rora

dian

s]

0 100 200

-1

0

1

2

Height

[mm]

[mic

rons

]

0 100 200

-500

0

500

Hitmap

[mm]

[nm

]

0

5

10

15

20 17.29

4.54

[HP

D in

arc

sec

s]

Estimated Performance

prepost

prepost

prepost

prepost

0 100 200-100

0

100

200Slope

[mm]

[mic

rora

dian

s]

0 100 200-2

-1

0

1

2

3

Height

[mm]

[mic

rons

]

0 100 200-400

-200

0

200

400

600

Hitmap

[mm]

[nm

]

0

5

10

1512.33

4.25

[HP

D in

arc

sec

s]

Estimated Performance

prepost

prepost

prepost

prepost

Single meridian parabolic segment

Single meridian hyperbolic segment

• Second correction used the same ART shell from correction 1, but on a different azimuthal region.

• 3 meridians at 24° separation were corrected.

• Corrections customised for each meridian were used.

• When considering the overlap regions between meridians, an improvement of 7.9 arc-sec was estimated post correction.

Page 15: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Correction 2 – X-ray testing

Higher frequency- correction

Key point

A factor of >2 improvement has been observed in X-rays from a single stage of correction.

Further results and information can be found in the paper:

Kilaru, K. et al., “Progress in differential deposition for improving the figures of full-shell astronomical grazing incidence x-ray optics”, Proc. of SPIE 9603, 96031F, 2015

Page 16: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Presentation outline

Introduction Horizontal chamber Vertical chamber Summary, conclusion and future

work

Page 17: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Challenges for segmented glass correctionSEGMENTED GLASS OPTICS Shape – segmented, leading

to a less rigid structure. Material – borosilicate,

lightweight, but easily deformed.

Mounting – point fixture, where the optics are held at discreet points.

NI-CO REPLICATED OPTICS Shape – full shell, rigid

structure. Material – Ni-Co alloy, heavier

but less prone to deformation.

Mounting – collet fixture, where the optic is held uniformly around its circumference.

Page 18: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Vertical chamber hardware

• 1m in diameter, 1.3m in height.• Vertical translation provided by a portable tower which has a travel of

~680mm in the vertical direction.• The 360° rotation is provided by an annular platform. • Optical encoders are used on both the translation and rotation to ensure

accurate positioning and feedback.• A 1 inch DC magnetron is to sputter the material for the differential

deposition process.

Translation tower

Optic

Mask and slit

Kinematic mountTip/tilt

stage

Ceramic

Magnetron

The slumped glass optics presented have been developed by NASA GSFC.

Page 19: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Metrology – Form Talysurf

Photo courtesy of Lewis Moore, NASA tribology group

Due to the requirement for accurate alignment and repeatability a kinematic mount has been developed to ensure accurate positioning of the optic relative to the profiler’s stylus between coatings.

The final profile, which is used to define the required correction, is composed of 2 sets of 5 repeat measurements with the optic being repositioned between each set.

Typically the accuracy of alignment between placements is within 10/20 microns.

Page 20: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Initial experimentation: Optic 2, coating 1

Initial experimentation used an aluminium fixture which held the optic along its azimuthal length.

Successful corrections were obtained from targeting small localised regions.

Optic 2 – coating 1

Page 21: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Initial experimentation:Optic 2, coating 3

Optic 2 – coating 3

The third coating was successful in correcting the first half of the optic; however the latter half exhibited an artefact. Furthermore subsequent optics all demonstrated similar defects after 1-3 coatings.The following were investigated: stress, mounting and thermal effects.Results indicated that all three could be factors and as such the mount was redesigned with ceramic components (to match the optic’s cte) in addition to different fixture points.

Page 22: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Ceramic mount results

Page 23: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Ceramic mount results

These initial results from the ceramic mount demonstrate the gradual improvement of the slumped glass optic after each coating.

Further coatings upon this optic were abandoned due to loss of positioning accuracy, this has been rectified for future optics and coatings.

Page 24: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Presentation outline

Introduction Horizontal chamber Vertical chamber Summary, conclusion and future

work

Page 25: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Summary, conclusion and future work: Horizontal

Summary and conclusion• An improvement of a factor >2 has been measured

in X-rays from a NiCo full shell astronomical optic.• Improvements by a factor of 3 are observed in VLTP

metrology data.• Results indicate that overlap regions between

meridians and undesired scatter from the gas inlets of the magnetron mask are currently limiting the full scope for the correction.

Future work

• To perform a full 360° correction of a NiCo full shell astronomical optic.

• To use different width slits to target different spatial frequencies to further improve the resolution.

• To improve the efficiency of the Differential Deposition process through incorporating in-situ metrology.

Gas inlet

Page 26: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

Summary, conclusion and future work: Vertical

Summary and conclusion• The differences and challenges of the slumped glass

optics versus the NiCo optics have been identified.• Early results were presented which indicated

sensitivity of the glass optics to: stress, mounting and thermal effects.

• The redesigned ceramic mount demonstrated successful corrections after several coatings.

• Slumped glass optics can be corrected via the Differential Deposition method.

Future work

• To ensure consistent correction after several coating using the ceramic mount.

• To implement the single meridian correction into a global full optic correction.

Page 27: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

AcknowledgementsThe author wishes to acknowledge:

Chip Moore at the MSFC Tribology Laboratory for use of the metrology equipment.

Will Zhang at NASA’s GSFC for supplying the slumped glass optics for the experiments.

All those who helped in the construction of the vacuum chambers.

and the X-ray astronomy group at NASA’s MSFC

Thank you for your attention!

Page 28: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015
Page 29: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

29

Initial Results – Stress?Stress in a thin film can be estimated using Stoney’s equation,

σf = film stressE = Young’s modulus of the substrateν = Poisson’s ratio of the substrateroc = measured change in radius of curvaturetf = film thickness

Borosilicate Glass wafer

Measured stress [MPa]

Wafer 1 119Wafer 2 175Wafer 3 172Wafer 4 248

Average measured stress = 179MPa (Tensile)

This is an active area of investigation with several options: -1. Reduce the stress through

changing the coating parameters (gas pressure, power etc.)

2. Create an FEA model of the stress to predict its effects.

3. Use the stress to correct the low order spatial frequencies within the surface.

9603-46

Page 30: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

30

Initial Results – Mounting

Coating direction

Second, the mount was flipped to reverse the direction of coating to see if there was a mechanical influence. The results indicate that there could be a mechanical effect and this warrants further investigation.

9603-46

Page 31: Carolyn Atkins, Kiranmayee Kilaru, Brian Ramsey, Mikhail Gubarev, Steve O’dell, Will W. Zhang. AXRO 2015, Prague, Czech Republic, 8 th December 2015

31

Initial Results - Temperature

Thermocouples have been set up within the vacuum chamber to measure the surface temperature of different components during coating.

Options to minimise the effects of thermal mismatch include: matching the cte of the mount to that of the optic; and modelling the effects to offset them in the correction

9603-46

Gas in (Ar)

Power on

Power off

Air in