cartridge filter cartridge
TRANSCRIPT
CARTRIDGE
FILTERS
AND
ACCESSORIES
At USFilter, our mission is to provide the products and services you
need to meet your water requirements — anytime, anyplace. An
example of this offering is our complete line of cartridge filtration
products shown in this catalog. Be it a sediment removal filter
for the pretreatment of an RO system or validated submicron
filtration of water used to manufacture
WFI quality water, USFilter is your one
stop source for your filtration needs. As the
world’s largest water treatment company,
we offer a wide range of other capabilities, reliable products and
services, combined with experience and technical knowledge you can
trust. Give us a call so we can work with you to deliver a solution that
meets your most stringent specifications. Call our 24-hour Customer
Service at 800-466-7873 for information and support.
Cartridge Filters and Accessories
CARTRIDGE END-CAPS . . . . . . . . . . . . . . . . . . . . . . . . 2
NOMINALLY-RATED CARTRIDGES
DI Gard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
ROGARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
NT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Prepure DP™. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Postpure PP™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
ABSOLUTE-RATED CARTRIDGES
NA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
WN Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
WE Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
DI Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
VH Series (Validated) . . . . . . . . . . . . . . . . . . . . . . 12
PV Series (Validated) . . . . . . . . . . . . . . . . . . . . . . 13
VENT FILTERS
EA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
VP Series (Validated) . . . . . . . . . . . . . . . . . . . . . . 15
Vent Capsule . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
SPECIALTY FILTERS
UF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Point-of-Use Capsule. . . . . . . . . . . . . . . . . . . . . . . 18
Pulverized Activated Carbon . . . . . . . . . . . . . . . . . 19
Granular Activated Carbon . . . . . . . . . . . . . . . . . . 20
HOUSINGS
316 Stainless Steel, Single Tube (Code F). . . . . . . . . 21
316L Stainless Steel, Single Tube (Code 0) . . . . . . . . 22
304 Stainless Steel, 5-Round, Multi-Tube . . . . . . . . . 23
304 Stainless Steel, 6-Round, Multi-Tube . . . . . . . . . 24
316 Stainless Steel, Multi-Tube . . . . . . . . . . . . . . . . 25
316L Electropolished Stainless Steel, Multi-Tube . . . . 26
Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Natural Polypropylene . . . . . . . . . . . . . . . . . . . . . 28
T A B L E O F
C O N T E N T S
Taking Care of the World's Water
24-HR CUSTOMER SERVICE: (800) 466-7873 2
Code 10 Style CartridgeSingle open end with
1-120 internal O-Ring at open end
Code F Style CartridgesFlat gaskets
Code O Style Cartridges2-222 O-Ring Outlet
Code 5 Style Cartridges2-222 O-Ring Outlet with spear assembly
Code 7 Style Cartridges2-226 O-Ring locking outlet with spear assembly
CARTRIDGE DESIGN DESCRIPTION CODE
Gaskets compressed on knife edge seal Fof housing
O-rings are located externally 0on the cartridge, other end flat
O-rings are located externally 5on the cartridge, other end spear
227 O-rings are located externally 7on the cartridge. The O-ring adapter locks into the housing. Spear assembly on other end
Single O-ring located inside 10the cartridge
The following table is presented as reference when ordering filter cartridges. For moredetailed information, please contact our Technical Support Team at 800-875-7873 ext. 5000.
Cartridge End Cap Configuration
TECHNICAL SUPPORT (800) 875-7873 EXT. 5000 3
DI GARD™ String Wound Prefiltration Cartridges
CARTRIDGE SPECIFICATIONSDimensions
Diameter (OD) . . . . . . . . . . 2.5" (6.5 cm)Length (in) . . . . . . . . . . . . 9.75, 10, 19.5, 20, 29.25, 30, 40
Materials
FCCS . . . . . . . . . . . . . . . . . Bleached white cotton fiber string media with polypropylene coreFCPS . . . . . . . . . . . . . . . . . Polypropylene fiber string media with polypropylene core FCPX . . . . . . . . . . . . . . . . . Surfactant-free polypropylene fiber string media with polypropylene coreNOTE: Code F cartridges (0.5 µm) have santophrene end seals.
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . 140°F (60°C)Maximum Differential Pressure @ 25°C. . . . . 50 psi (3.4 bar)Micron Ratings . . . . . . . . . . . . . . . . . . . . . . . 0.5, 1, 3, 5, 10, 20, 50 MicronsFiltration Efficiency . . . . . . . . . . . . . . . . . . . . Nominal 90%
Recommended Water Flow Rates
5.0 gpm/10" length (18.9 lpm/10" length)
ORDERING INFORMATIONCatalog Number and Description
FCXX . . . . . . . . . . . . . . . . FCCS = cotton string fiber cartridgeFCPS = polypropylene string fiber cartridgeFCPX = surfactant-free polypropylene string fiber cartridge
F. . . . . . . . . . . . . . . . . . . . Cartridge Code: F = double open end
XX . . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 19 = 19.5, 20 = 20, 29 = 29.25, 30 = 30, 40 = 40
XX . . . . . . . . . . . . . . . . . . Micron Rating: S5 = 0.5µm, 01 = 1 µm, 03 = 3 µm, 05 = 5 µm, 10 = 10 µm, 20 = 20 µm, 50 = 50 µm
To figure your order number, replace the X with one of the numbered or lettered optionsbeside it. Note: Not all part number combinations are available; consult TechnicalSupport for assistance.
• Designed for a variety of prefiltration applications such as SDI (service deionization),reverse osmosis, and CDI® (Continuous Deionization) Systems
• String wound type filter with your choice of cotton, industrial or surfactant-freepolypropylene string over a polypropylene core
• Large void volume design for low-cost, reliable filtration performance with highcontaminant holding capacity
• Continuous filter winding in 20-, 30-, and 40-inch lengths prevents by-passing orexcessive pressure drops at the seams
• Gasketed end caps on 0.5 µm rated filters for positive sealing that eliminates by-passing
• Surfactant-free FCPX style filter meets USP Class VI Biological Tests for Plastics requirements
2.0Cle
an P
ressu
re D
rop
(PSI
D)
BAR
LPM
1.6
.14
.08
.04
.02
1.2
.8
.4
00 1 2 3 4 5
50 µm
20 µm
10 µm5 µm3 µm
1µm0.5 µm
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP
Water Flow Rate/10" cartridge (GPM)
4 12 168
24-HR CUSTOMER SERVICE: (800) 466-7873 4
ROGARD™ Graded Density PolypropyleneMedia Filter Cartridge
CARTRIDGE SPECIFICATIONSDimensions
Diameter (OD) . . . . . . . . . . 2.5" (6.5 cm)Length (in) . . . . . . . . . . . . 9.75, 10, 12, 19.5, 20, 30, 31, 40
Materials
Media . . . . . . . . . . . . . . . . Melt Blown polypropyleneCore . . . . . . . . . . . . . . . . . Integral polypropylene coreO-Rings . . . . . . . . . . . . . . . Silicone o-ringsGaskets . . . . . . . . . . . . . . . Santophrene end seals
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . 160°F (70°C)Maximum Differential Pressure @ 25°C. . . . . 50 psi (3.4 bar)Micron Ratings . . . . . . . . . . . . . . . . . . . . . . . 1, 3, 5, 10, 20, 25, 50, 75 micronsFiltration Efficiency . . . . . . . . . . . . . . . . . . . . Nominal 90%
Recommended Water Flow Rates
5.0 gpm/10" length (18.9 lpm/10" length)
ORDERING INFORMATIONCatalog Number and Description
FCRO. . . . . . . . . . . . . . . . . Rogard II all polypropylene depth cartridge
X . . . . . . . . . . . . . . . . . . . Cartridge Code: F = double open end (1&5 µm w/gasket) 0 = 2-222 o-rings (12&20", 1&5 µm only)N = double open end (1, 3 & 5 µm – no gasket)
XX . . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 12 = 12, 19 = 19.5, 20 = 20, 30 = 30, 31 = 31, 40 = 40
XX . . . . . . . . . . . . . . . . . . Micron Rating: 01 = 1 µm, 03 = 3 µm, 05 = 5 µm, 10 = 10 µm,20 = 20 µm, 25 = 25 µm, 50 = 50 µm, 75 = 75 µm
To figure your order number, replace the X with one of the numbered or lettered optionsbeside it. Note: Not all part number combinations are available; consult TechnicalSupport for assistance.
• Designed for a variety of prefiltration applications such as SDI (service deionization), reverse osmosis and CDI® (Continuous Deionization) Systems
• Graded density melt spun polypropylene media design for exceptional throughput, with high contaminant holding capacity
• Gasketed end caps on 1, 3 and 5 µm rated filters for positive sealing that eliminates by-passing
• ROGARD cartridge filters meet the criteria for USP Class VI Biological Tests for Plastics, ensuring that no surfactants or coatings interfere with the application, making these cartridges ideal for use in the food and beverage industry
• Available in a variety of lengths and pore sizes to meet a wide range of applications
Clean
Pre
ssure
Dro
p (PS
ID)
BAR
Water Flow Rate/10" Cartridge (GPM)
.2
.3
75µm
50µm
25µm20µm
10µm5µm1µm 3µm
4 32 LPM2812 16 20 248
.02
.01
.03
2 3 5 7 91 4 6 8 100
.05
.1
.15
.25
.35
.4
.45
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP
TECHNICAL SUPPORT (800) 875-7873 EXT. 5000 5
NT Series Graded Pore Polypropylene Depth Filter Cartridge
CARTRIDGE SPECIFICATIONSDimensions
Diameter (OD) . . . . . . . . . . 2.5" (6.5 cm)Length (in) . . . . . . . . . . . . 9.75, 10, 20, 30, 40
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene caps and coreMedia . . . . . . . . . . . . . . . . CoLD fiber melt blown polypropyleneSeals . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . 180°F (82°C) @ 15 psid (1.0 bar)Maximum Differential Pressure @ 30°C. . . . . 60 psi (4.1 bar)Filtration Efficiency . . . . . . . . . . . . . . . . . . . . Nominal 90%
Recommended Water Flow Rates
0.5 – 3 micron. . . . . . . . . . 2.0 gpm/10" length (7.6 lpm/10" length)5 – 75 micron . . . . . . . . . . 5.0 gpm/10" length (18.9 lpm/10" length)
Sanitizing Agents
Chlorine, hydrogen peroxide
ORDERING INFORMATIONCatalog Number and Description
FCNT . . . . . . . . . . . . . . . . . Polypropylene CoLD depth filter cartridge
X . . . . . . . . . . . . . . . . . . . Cartridge Code: 1 = double open end w/ internal o-ringsF = double open end (0.5 – 5 mm w/gasket)N = double open end (0.5 – 5 mm – no gasket)
XX . . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40
XX . . . . . . . . . . . . . . . . . . Micron Rating: S5 = 0.5 µm, 01 = 1 µm, 03 = 3 µm, 05 = 5 µm, 10 = 10 µm, 15 = 15 µm, 20 = 20 µm, 30 = 30 µm, 40 = 40 µm, 50 = 50 µm, 75 = 75 µm
To figure your order number, replace the X with one of the numbered or lettered optionsbeside it. Note: Not all part number combinations are available; consult TechnicalSupport for assistance.
• Designed to deliver precision prefiltration through the patented advanced melt blownCoLD® technology structure that incorporates large diameter fibers for strength whilemaintaining small fibers for filtration
• CoLD fiber technology melt blown structure delivers exceptional retention, mechanicalstrength and on-stream life
• Graded pore structure throughout the filter’s depth provides high contaminant holding capacity
• High purity, 100% polypropylene construction is free of surfactants, binders and adhesives
• FDA listed materials of construction
CoLD is a registered trademark of Filterite Corporation.
Clean
Pre
ssure
Dro
p (PS
ID)
BAR
Water Flow Rate/10" Cartridge (GPM)
3
5
15µm20µm
10µm
5µm
3µm
1µm0.5µm
.3
.2
.1
.4
2 3 5 7 91 4 6 8 100
1
2
4
6
7
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP
4 32 36 LPM2812 16 20 248Cle
an P
ressu
re D
rop (
PSID
)
BAR
Water Flow Rate/10" Cartridge (GPM)
0.3
0.5
75µm
30µm40µm50µm .03
.02
.01
.04
2 3 5 7 91 4 6 8 100
0.1
0.2
0.4
0.6
0.7
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP
4 32 36 LPM2812 16 20 248
24-HR CUSTOMER SERVICE: (800) 466-7873 6
CARTRIDGE SPECIFICATIONSDimensions
Diameter (OD) . . . . . . . . . . 2.6" (6.6 cm)Length (in) . . . . . . . . . . . . 9.75, 10, 20, 30, 40
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene caps, core and cageMedia . . . . . . . . . . . . . . . . Non-woven melt blown polypropyleneSeals . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . 140°F (60°C) @ 30 psid (2.1 bar)Maximum Differential Pressure @ 20°C. . . . . 60 psi (4.1 bar)Filtration Efficiency . . . . . . . . . . . . . . . . . . . . Nominal 90%
Recommended Water Flow Rates
0.5 – 5 micron. . . . . . . . . . 2.0 gpm/10" length (7.6 lpm/10" length)10 – 50 micron . . . . . . . . . 5.0 gpm/10" length (18.9 lpm/10" length)
Sanitizing Agents
Chlorine or hydrogen peroxide
ORDERING INFORMATIONCatalog Number and Description
FCDP . . . . . . . . . . . . . . . . . All polypropylene depth filter cartridge
X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 7 = 2-226 o-rings w/spear1 = double open end w/internal o-ringsF = double open end w/flat gasket seal
XX . . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40
XX . . . . . . . . . . . . . . . . . . Micron Rating: S5 = 0.5 µm, 01 = 1 µm, 03 = 3 µm, 05 = 5 µm, 10 = 10 µm, 25 = 25 µm, 50 = 50 µm
To figure your order number, replace the X with one of the numbered or letteredoptions beside it. Note: Not all part number combinations are available; consultTechnical Support for assistance.
Prepure DP™ Graded Density PolypropyleneDepth Media Filter Cartridge
• Composed of graded density melt blown polypropylene depth media for high efficiency prefiltration and post-filtration of DI resin applications
• Prepure DP filtration cartridges feature high contaminant loading due to graded densitydepth filtration media construction
• Filter meets the criteria for USP Class VI Biological Tests for Plastics, ensuring that no surfactants or coatings interfere with the application, making these ideal for use in the food and beverage industry
• All materials are FDA listed for contact with food and beverages.
• Virgin polypropylene construction with fusion welding minimizes extractables
Clean
Pre
sure
Dro
p (PS
ID)
Water Flow Rate/10" Cartridge (GPM)
.2
0
.4
.6
.8
1.2
1.4
1.6
1.8
2.0
2.4
3.0
50 µm
25 µm10 µm
5 µm
3 µm
1 µm
0.5 µm
1 2 3 4 5
LPM
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP
4 12 168
BAR
.18
.04
.06
.02
.12
.14
.10
TECHNICAL SUPPORT (800) 875-7873 EXT. 5000 7
Postpure PP™ Graded Density PleatedPolypropylene Depth Media FilterCartridge
CARTRIDGE SPECIFICATIONS
Dimensions
Diameter (OD) . . . . . . . . . . 2.6" (6.6 cm)Length (in) . . . . . . . . . . . . 10, 20, 30
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene caps, core and cageMedia . . . . . . . . . . . . . . . . Pleated, non-woven melt blown polypropyleneSeals . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . 140°F (60°C) @ 40 psid (2.8 bar)Maximum Differential Pressure @ 25°C. . . . . 75 psi (5.1 bar)Filtration Efficiency . . . . . . . . . . . . . . . . . . . . nominal 90%
Recommended Water Flow Rates
0.3 – 1 micron. . . . . . . . . . 2.0 gpm/10" length (7.6 lpm/10" length)3 – 30 micron . . . . . . . . . . 8.0 gpm/10" length (30.1 lpm/10" length)
Sanitizing Agents
Chlorine, hydrogen peroxide, in-line with hot water (82°C) for one hour, autoclaved for 20 minutes at 121°C under no load conditions.
ORDERING INFORMATIONCatalog Number and Description
FCPP . . . . . . . . . . . . . . . . . All polypropylene, pleated, nominal depth filter cartridge
X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 7 = 2-226 o-rings locking tabs w/spear1 = double open end w/internal o-ringsF = double open end w/flat gasket seal
XX . . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30
XX . . . . . . . . . . . . . . . . . . Micron Rating: S3 = 0.3 µm, S6 = 0.6 µm, 01 =1 µm, 03 = 3 µm, 05 = 5 µm, 10 = 10 µm, 30 = 30 µm
To figure your order number, replace the X with one of the numbered or letteredoptions beside it. Note: Not all part number combinations are available; consultTechnical Support for assistance.
• Composed of graded-density, pleated, polypropylene depth media for high efficiency postfiltration of DI resin applications
• Filter components meet USP Class VI Biological Tests for Plastics, ensuring that no surfactants or coatings interfere with the application, making these ideal for use in the food and beverage industry
• Postpure DP filtration cartridges feature high contaminant loading due to gradeddensity depth filtration media construction
• Virgin polypropylene construction with fusion welding minimizes extractables
• All materials are FDA listed for contact with food and beverages
Clean
Pre
ssure
Dro
p (PS
ID)
Water Flow Rate/10" Cartridge (GPM)
0.5
1.0
1.5
2.0
2.5
3.0
.05
0
.10 BAR
.15
.20
2 4 6 8 100
0.3 µ
m
0.6 µm
1 µm
3 µm
5 µm10 & 30 µm
LPM
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP
8 24 3216
24-HR CUSTOMER SERVICE: (800) 466-7873 8
NA Series Absolute Rated PolypropyleneDepth Filter Cartridge
• Designed to deliver precision filtration through the patented advanced melt blown CoLD®
technology structure that incorporates large diameter fibers for strength while maintaining small fibers for filtration
• Patented CoLD fiber technology melt blown structure provides outstanding retentionefficiency, mechanical strength, and long on-stream life
• Multi-zone design produces a gradient pore structure to provide pre- and post-filtration in a single cartridge
• Absolute filtration with sharp particle cutoffs deliver precise removal efficiencies
• High purity, 100% polypropylene construction is free of surfactants, binders and adhesives making these cartridges ideal for use in food and beverage applications
CARTRIDGE SPECIFICATIONSDimensions
Diameter (OD) . . . . . . . . . . 2.5" (6.5 cm)Length (in) . . . . . . . . . . . . 9.75, 10, 20, 30, 40
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene caps and coreMedia . . . . . . . . . . . . . . . . CoLD fiber melt blown polypropyleneSeals . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . 180°F (82°C) @ 15 psid (1.0 bar)Maximum Differential Pressure @ 30°C. . . . . 60 psi (4.1 bar)Filtration Efficiency . . . . . . . . . . . . . . . . . . . . 100% Absolute
Recommended Water Flow Rates
0.5 – 5 micron. . . . . . . . . . 2.0 gpm/10" length (7.6 lpm/10" length)10 – 70 micron . . . . . . . . . 5.0 gpm/10" length (18.9 lpm/10" length)
Sanitizing Agents
Chlorine, hydrogen peroxide
ORDERING INFORMATIONCatalog Number and Description
FCNA. . . . . . . . . . . . . . . . . Absolute rated CoLD depth filter cartridge
X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings7 = 2-226 o-rings w/spear1 = double open end w/ internal o-ringsF = double open end w/flat gasket seal5 = 2-222 o-rings w/spear
XX . . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40
XX . . . . . . . . . . . . . . . . . . Micron Rating: S5 = 0.5 µm, 01 = 1 µm, 03 = 3 µm, 05 = 5 µm, 10 = 10 µm, 15 = 15 µm, 20 = 20 µm, 30 = 30 µm, 50 = 50 µm, 70 = 70 µm
To figure your order number, replace the X with one of the numbered or lettered optionsbeside it. Note: Not all part number combinations are available; consult TechnicalSupport for assistance.
Clean
Pre
ssure
Dro
p (PS
ID)
BAR
Water Flow Rate/10" Cartridge (GPM)
3
5
15µm20µm
10µm
5µm
1µm 3µm0.5µm
.3
.2
.1
.4
2 3 5 7 91 4 6 8 100
1
2
4
6
7
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP
4 32 36 LPM2812 16 20 248Cle
an P
ressu
re D
rop (
PSID
)
BAR
Water Flow Rate/10" Cartridge (GPM)
0.3
0.5
30µm
50µm
70µm.03
.02
.01
.04
2 3 5 7 91 4 6 8 100
0.1
0.2
0.4
0.6
0.7
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP
4 32 36 LPM2812 16 20 248
TECHNICAL SUPPORT (800) 875-7873 EXT. 5000 9
WN Series Pleated Polysulfone Membrane Filter Cartridge
CARTRIDGE SPECIFICATIONSDimensions
Diameter (OD) . . . . . . . . . . 2.6" (6.6 cm)Length (in) . . . . . . . . . . . . 9.75, 10, 20, 30, 40
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene caps, core and cageMedia . . . . . . . . . . . . . . . . Single layer asymmetric hydrophilic polysulfoneSeals . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . 203°F (95°C) @ 20 psid (1.4 bar)Maximum Differential Pressure @ 20°C. . . . . 80 psi (5.5 bar)Filtration Efficiency . . . . . . . . . . . . . . . . . . . . 100% Absolute
Recommended Water Flow Rates
0.05 micron . . . . . . . . . . . . 1.3 gpm/10" length (4.9 lpm/10" length)0.1 micron. . . . . . . . . . . . . 1.7 gpm/10" length (6.4 lpm/10" length)0.2 micron. . . . . . . . . . . . . 3.0 gpm/10" length (11.3 lpm/10" length)0.45 micron . . . . . . . . . . . . 5.5 gpm/10" length (20.8 lpm/10" length)
Sanitizing Agents
5% Chlorine, 3% hydrogen peroxide
ORDERING INFORMATIONCatalog Number and Description
FCWN . . . . . . . . . . . . . . . . Filter cartridge single layer polysulfone
X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings5 = 2-222 o-rings w/spear1 = double open end w/ internal o-rings7 = 2-226 o-rings w/locking tabs/spear endF = double open end w/flat gasket seal
XX . . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40
XX(X) . . . . . . . . . . . . . . . Micron Rating: S05 = 0.05 µm, S1 = 0.1 µm, S2 = 0.2 µm, S4 = 0.45 µm
To figure your order number, replace the X with one of the numbered or lettered optionsbeside it. Note: Not all part number combinations are available; consult TechnicalSupport for assistance.
• Composed of pleated highly asymmetric polysulfone membrane over a non-woven polypropylene support layer
• For high flow rates and low pressure drops, absolute rated filters are designed for postfiltration in high purity water applications
• The highly asymmetric membrane delivers longer on-stream life than conventional membrane products
• High-purity construction materials are factory rinsed with DI water for quick on-streamrinse up with a minimum of throughput
• All polypropylene parts and thermal welding minimizes extractables
• All materials are FDA listed and meet criteria for USP Class VI Biological tests forplastics, ensuring that no surfactants or coatings interfere with the application
Clean
Pre
ssure
Dro
p (PS
ID) 3.0
2.5
1.5
0.5
2.0
1.0
0 1 2 3 4 5 6 7
BAR
0.05µm 0.1µm
0.2µm
0.45µm
Water Flow Rate/10" Cartridge (GPM)
LPM
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP
4 12 2416 208
24-HR CUSTOMER SERVICE: (800) 466-7873 10
CARTRIDGE SPECIFICATIONSDimensions
Diameter (OD) . . . . . . . . . . 2.6" (6.6 cm)Length (in) . . . . . . . . . . . . 9.75, 10, 20, 30, 40
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene caps, core and cageMedia . . . . . . . . . . . . . . . . Double layer asymmetric hydrophilic polysulfoneSeals . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . 203°F (95°C) @ 20 psid (1.4 bar)Maximum Differential Pressure @ 20°C. . . . . 80 psi (5.5 bar)Filtration Efficiency . . . . . . . . . . . . . . . . . . . . 100% Absolute
Recommended Water Flow Rates0.02 micron . . . . . . . . . . . . 0.6 gpm/10" length (2.3 lpm/10" length)0.1 micron. . . . . . . . . . . . . 1.2 gpm/10" length (4.5 lpm/10" length)0.2 micron. . . . . . . . . . . . . 2.2 gpm/10" length (8.3 lpm/10" length)0.45 micron . . . . . . . . . . . . 3.2 gpm/10" length (12.1 lpm/10" length)
Sanitizing Agents
5% Chlorine or 3% hydrogen peroxide
Integrity Test
Pore Size . . . . . . . . . . . . . . Diffusional Flow (cc/min) @ Test Pressure per 10" length0.02 micron . . . . . . . . . . . . 20 @ 50 psig (3.4 bar)0.1 micron. . . . . . . . . . . . . 24 @ 25 psig (1.7 bar)0.2 micron. . . . . . . . . . . . . 18 @ 20 psig (1.4 bar)0.45 micron . . . . . . . . . . . . 15 @ 15 psig (1.0 bar)
ORDERING INFORMATIONCatalog Number and Description
FCWE. . . . . . . . . . . . . . . . . Filter cartridge double layer polysulfone
X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings5 = 2-222 o-rings w/spear1 = single open end w/ internal o-ring7 = 2-226 o-rings w/locking tabs/spear endF = double open end w/flat gasket seal
XX . . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40
XX(X) . . . . . . . . . . . . . . . Micron Rating: S02 = 0.02 µm, S1 = 0.1 µm, S2 = 0.2 µm, S4 = 0.45 µm
To figure your order number, replace the X with one of the numbered or lettered optionsbeside it. Note: Not all part number combinations are available; consult TechnicalSupport for assistance.
WE Series Pleated PolysulfoneMembrane Filter Cartridge
• Composed of a double layer of integrity testable, highly asymmetric polysulfonemembrane. These absolute rated filters offers superior bacteria and particle removal forhigh efficiency postfiltration for critical high purity water applications
• Long on stream life, high flow rates and low pressure drops result from the membrane asymmetry
• High-purity construction materials are factory flushed with DI water for quick on-streamrinse-up with a minimum of throughput
• All polypropylene parts and thermal welding minimizes extractables
• All materials are FDA listed for contact with food and beverages
Clean
Pre
ssure
Dro
p (PS
ID)
2.0
1.5
0.5
1.0
0 .5 1.0 1.5 2.0 2.5 3.0 3.5
0.02µm 0.1µm
0.2µm
0.45µm
Water Flow Rate/10" Cartridge (GPM)
BAR
LPM
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP
2 6 128 104
TECHNICAL SUPPORT (800) 875-7873 EXT. 5000 11
DI Series Pleated Hydrophilic PVDF Media Pharmaceutical/Biotech GradeFilter Cartridge
CARTRIDGE SPECIFICATIONSDimensions
Diameter (OD) . . . . . . . . . . 2.75" (7.0 cm)Length (in) . . . . . . . . . . . . 10, 20, 30, 40
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene caps, core and cageMedia . . . . . . . . . . . . . . . . Hydrophilic PVDFSeals . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . 176°F (80°C) @ 25 psid (1.7 bar)Maximum Differential Pressure @ 25°C. . . . . 50 psi (3.4 bar)Filtration Rating . . . . . . . . . . . . . . . . . . . . . . 100% Absolute
Recommended Water Flow Rates
0.1 micron. . . . . . . . . . . . . 0.5 gpm/10" length (1.9 lpm/10" length)0.2 micron. . . . . . . . . . . . . 1.0 gpm/10" length (3.8 lpm/10" length)
Sanitizing Agents
Chlorine, hydrogen peroxide
Integrity Test
Pore Size . . . . . . . . . . . Minimum Water Diffusional Flow (cc/min)Bubble Point @ Test Pressure per 10" length
0.1 µm. . . . . . . . . . . . . ≥ 70 psig (≥ 4.8 bar) ≤ 20 @ 56 psig (3.8 bar)0.2 µm. . . . . . . . . . . . . ≥ 45 psig (≥ 3.1 bar) ≤ 12 @ 30 psig (2.1 bar)
ORDERING INFORMATIONCatalog Number and Description
FCDI . . . . . . . . . . . . . . . . . Filter cartridge Water DI
X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings5 = 2-222 o-rings w/spear7 = 2-226 o-rings w/locking tabs/spear endF = double open end w/flat gasket seal
XX . . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30, 40 = 40
XX . . . . . . . . . . . . . . . . . . Micron Rating: S1 = 0.1 µm, S2 = 0.2 µm
To figure your order number, replace the X with one of the numbered or letteredoptions beside it. Note: Not all part number combinations are available; consultTechnical Support for assistance.
• Composed of a validatable, hydrophilic, PVDF membrane. Offering a high velocity DI water flush for quick rinse-up with no downstream contamination. These absoluterated filters offer superior bacteria and particle removal for critical high puritypostfiltration applications
• Filters have single PVDF membrane with two layers of polypropylene support media to ensure absolute bacteria retention with typical LRV >8
• The all PVDF membrane can be sanitized with chlorine, hydrogen peroxide or steam
• Virgin polypropylene construction with fusion welding minimizes extractables
• Cartridges are 100% integrity tested to verify absolute sub-micron particle retention
7
6
5
3
1
4
2
00 1 2 3 4 5
0.1 0.2
Water Flow Rate/10" Cartridge (GPM)
BAR
LPM
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP
4 12 168
Clean
Pre
ssure
Dro
p (PS
ID)
24-HR CUSTOMER SERVICE: (800) 466-7873 12
CARTRIDGE SPECIFICATIONSDimensions
Diameter (OD) . . . . . . . . . . 2.75" (7.0 cm)Length (in) . . . . . . . . . . . . 10, 20, 30, 40
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene, core and cage, nylon endcapsMedia . . . . . . . . . . . . . . . . PolyethersulphoneSeals . . . . . . . . . . . . . . . . . Silicone o-rings
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . 158°F (70°C) @ 25 psid (1.7 bar)Maximum Differential Pressure @ 25°C. . . . . 72 psi (5.0 bar)Filtration Rating . . . . . . . . . . . . . . . . . . . . . . 100% AbsoluteToxicity . . . . . . . . . . . . . . . . . . . . . . . . . . . . Non-toxic by USP Class VI Biological test for plasticsValidation . . . . . . . . . . . . . . . . . . . . . . . . . . HIMA Bacterial challenge test methods (107 organisms/cm2)
Recommended Water Flow Rates
0.1 µm . . . . . . . . . . . . . . . 0.6 gpm/10" length (2.3 lpm/10" length)0.2 µm . . . . . . . . . . . . . . . 2.0 gpm/10" length (7.6 lpm/10" length)0.45 µm . . . . . . . . . . . . . . 3.0 gpm/10" length (11.4 lpm/10" length)
Sanitizing Agents
Chlorine, hydrogen peroxide, autoclaved for 20 minutes at 121°C under no load conditions.
Integrity Test
Pore Size . . . . . . . . . . . . . . . . . . . Minimum Water Diffusional Flow (cc/min)Bubble Point @ Test Pressure per 10" length
0.1 µm . . . . . . . . . . . . . . . . . . . . ≥ 31 psig ≤ 27 @ 70 psig (4.9 bar)0.2 µm . . . . . . . . . . . . . . . . . . . . ≥ 49 psig ≤ 16 @ 40 psig (2.7 bar)0.45 µm. . . . . . . . . . . . . . . . . . . . ≥ 36 psig ≤ 16 @ 25 psig (1.7 bar)
ORDERING INFORMATIONCatalog Number and Description
FCVH . . . . . . . . . . . . . . . . . Filter cartridge pharmaceutical/validated
X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 1 = single open end w/internal o-ring5 = 2-222 o-rings w/spear end7 = 2-226 o-rings w/locking tabs/spear end
XX . . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30, 40 = 40
XX . . . . . . . . . . . . . . . . . . Micron Rating: S1 = 0.1 µm, S2 = 0.2 µm, S4 = 0.45 µm
VH Series Pleated PES Media Pharmaceutical Grade Filter Cartridge
• Cartridge is a validated, pleated polyethersulphone membrane over a non-woven polyester support layer
• Absolute rated
• Code 0, Code 5, Code 7 and Code 10 configurations are available in 10, 20 30, and 40-inlengths that are 100% tested in manufacturing to ensure absolute bacteria retention with typical reduction of >107/cm2
• Meet current USP Class VI biological test for plastics, with a validation certificate available tosupport the bacteria challenge results.
• Contain no surfactants or coatings to interfere with your application, and the thermo-plasticconstruction process minimizes extractables.
• Supported single layer membrane ensures strength, while exhibiting low pressure drop andexceptionally high flow rates
• These validated cartridges can be sterilized by autoclaving
BAR
Clean
Pre
ssure
Dro
p (PS
ID)
2.0
1.5
0.5
1.0
0 .5 1.0 1.5 2.0 2.5 3.0
0.1µm
0.2µm
0.45µm
Water Flow Rate/10" Cartridge (GPM)
LPM
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP
2 6 8 104
To figure your order number, replace the X with one of the numbered orlettered options beside it. Note: Not all part number combinations areavailable; consult Technical Support for assistance.
TECHNICAL SUPPORT (800) 875-7873 EXT. 5000 13
PV Series Pleated Hydrophilic PVDF MediaPharmaceutical Grade Filter Cartridge
• Cartridge is a validated, pleated hydrophilic PVDF membrane over a non-woven polypropylene support layer
• Absolute rated at 0.2 µm
• Code 0, Code 5, and Code 7 configurations are available in 10, 20 30, and 40-in lengthsthat are 100% tested in manufacturing to ensure absolute bacteria retention with typicaltitre reduction of >107/cm2
• Meet current USP Class VI biological test for plastics, with a validation certificateavailable to support the bacteria challenge results.
• Contain no surfactants or coatings to interfere with your application, and the thermo-plasticconstruction process minimizes extractables.
• Supported single layer membrane ensures strength, while exhibiting low pressure drop andexceptionally high flow rates
• These validated cartridges can be sterilized by autoclaving
CARTRIDGE SPECIFICATIONSDimensions
Diameter (OD) . . . . . . . . . . 2.75" (7.0 cm)Length (in) . . . . . . . . . . . . 10, 20, 30, 40
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene caps, core and cageMedia . . . . . . . . . . . . . . . . PVDFSeals . . . . . . . . . . . . . . . . . Silicone o-rings
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . 170°F (80°C) @ 25 psid (1.7 bar)Maximum Differential Pressure @ 25°C. . . . . 80 psi (5.5 bar)Filtration Rating . . . . . . . . . . . . . . . . . . . . . . 100% AbsoluteToxicity . . . . . . . . . . . . . . . . . . . . . . . . . . . . Non-toxic by USP Class VI Biological test for plasticsValidation . . . . . . . . . . . . . . . . . . . . . . . . . . HIMA Bacterial challenge test methods (107 organisms/cm2)
Recommended Water Flow Rates
0.2 µm . . . . . . . . . . . . . . . 1.0 gpm/10" length (3.8 lpm/10" length)
Sanitizing Agents
Chlorine, hydrogen peroxide, autoclaved for 20 minutes at 121°C under no load conditions.
Integrity Test
Pore Size . . . . . . . . . . . . . . . . . . . Minimum Water Diffusional Flow (cc/min)Bubble Point @ Test Pressure per 10" length
0.2 µm . . . . . . . . . . . . . . . . . . . . ≥ 45 psig (≥ 3.1 bar) ≤ 13 @ 40 psig (3.1 bar)
ORDERING INFORMATIONCatalog Number and Description
FCPV . . . . . . . . . . . . . . . . . Filter cartridge pharmaceutical/validated
X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear end7 = 2-226 o-rings w/locking tabs/spear end
XX . . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30, 40 = 40
S2 . . . . . . . . . . . . . . . . . . Micron Rating: S2 = 0.2 µm
To figure your order number, replace the X with one of the numbered or lettered optionsbeside it. Note: Not all part number combinations are available; consult TechnicalSupport for assistance.
Clean
Pre
ssure
Dro
p (PS
ID)
Water Flow Rates/10" Cartridge (GPM)
4
8
12
16
FCPV 10S2
FCPV 20S2
FCPV 30S2
FCPV 40S2
20
64 LPM483216
.7
1.4
04 8 12 16 200
BAR
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP
24-HR CUSTOMER SERVICE: (800) 466-7873 14
EA Series Hydrophobic Polypropylene Media Vent Filter Cartridge
CARTRIDGE SPECIFICATIONSDimensions
Diameter (OD) . . . . . . . . . . 2.6" (6.6 cm)Length (in) . . . . . . . . . . . . 10, 20, 30
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene caps, core and cageMedia . . . . . . . . . . . . . . . . Hydrophobic asymmetric polysulfoneSeals . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . Ambient AirMaximum Differential Pressure @ 23°C. . . . . 60 psi (4.1 bar)Air Filtration Rating. . . . . . . . . . . . . . . . . . . . 0.02 µm 100% AbsoluteToxicity . . . . . . . . . . . . . . . . . . . . . . . . . . . . Non-toxic by USP Class VI Biological test for plastics
Sanitizing Agents
Chlorine, hydrogen peroxide or autoclaving
ORDERING INFORMATIONCatalog Number and Description
FCEA . . . . . . . . . . . . . . . . . Filter cartridge vent polysulfone
X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear end1 = double open end w/internal o-rings7 = 2-226 o-rings w/locking tabs/spear endF = double open end w/flat gasket seal
XX . . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30
S2 . . . . . . . . . . . . . . . . . . Micron Rating: S2 = 0.02 µm (air)
To figure your order number, replace the X with one of the numbered or lettered optionsbeside it. Note: Not all part number combinations are available; consult TechnicalSupport for assistance.NOTE: These filter cartridges should not be used as a combination air vent/wateroverflow device.
• Composed of a pleated hydrophobic highly asymmetric polysulfone membranerated at 0.02 µm absolute for sterile air filtration, storage tank venting applications
• Filter components meet current USP Class VI biological test for plastics
• Contain no surfactants or coatings to interfere with your application, and thethermo-plastic construction process minimizes extractables
• Asymmetric single layer membrane ensures strength, while exhibiting low pressuredrop and exceptionally high flow rates
• Sterilized by autoclaving
Pres
sure
Dro
p (PS
ID)
BAR
2.0
.12
.09
.06
.03
0
1.5
0.5
1.0
0 40
1000 2000 3000 4000
80 120 160Air Flow Rate/10" Cartridge (SCFM)
SLPM
AIR FLOW RATES AT NEAR ATMOSPHERIC PRESSURE (VENT APPLICATIONS)
TECHNICAL SUPPORT (800) 875-7873 EXT. 5000 15
VP Series Hydrophobic PTFE ValidatedMedia Vent Filter Cartridge
• Composed of a pleated, hydrophobic, PTFE, Teflon membrane rated at 0.2 µm absolute for sterile air filtration, storage tank venting applications
• Filter components meet the criteria of the USP Class VI Biological Test for Plastics
• These filters feature minimal pressure loss, long service life due to high void volume, andcan be repeatedly steam sterilized or autoclaved
• Filters are integrity testable and are fully validated by bacterial challenge (HIMA)
CARTRIDGE SPECIFICATIONSDimensions
Diameter (OD) . . . . . . . . . . 2.6" (6.6 cm)Length (in) . . . . . . . . . . . . 10, 20, 30
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene caps, core and cageMedia . . . . . . . . . . . . . . . . Hydrophobic Teflon PTFESeals . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
Operating Parameters
Maximum Temperature . . . . . . . . Ambient AirMaximum Differential Pressure @ 21°C. . . . . 72 psi (5.0 bar)Air Filtration Rating. . . . . . . . . . . . . . . . . . . . 0.2 µm AbsoluteToxicity . . . . . . . . . . . . . . . . . . . . . . . . . . . . Non-toxic by USP Class VI Biological test for plasticsValidation . . . . . . . . . . . . . . . . . . . . . . . . . . HIMA Bacterial challenge test methods (107 organisms/cm2 )
Sanitizing Agents
Chlorine, hydrogen peroxide, autoclaved for 20 minutes at 121°C under no load conditions.
Integrity Test
Pore Size . . . . . . . . . . . . . . Minimum Water Bubble Point0.2 µm . . . . . . . . . . . . . . . ≥ 14 psig (≥ 1.0 bar) 60 IPA/40 water
ORDERING INFORMATIONCatalog Number and Description
FCVP . . . . . . . . . . . . . . . . . Filter cartridge vent polysulfone
X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear end7 = 2-226 o-rings w/locking tabs/spear end
XX . . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30
S2. . . . . . . . . . . . . . . . . . . Micron Rating: S2 = 0.2 µm
To figure your order number, replace the X with one of the numbered or lettered optionsbeside it. Note: Not all part number combinations are available; consult TechnicalSupport for assistance.NOTE: These filter cartridges should not be used as a combination air vent/wateroverflow device.
Air Flow (SCFM)50 100 150 200
Pres
sure
Dro
p (PS
ID)
2.0
1.5
1.0
0.5
0
10" Cartridge 20" Cartridge
30" Cartridge
1000 2000 3000 4000 5000 6000SLPM
AIR FLOW RATES AT NEAR ATMOSPHERIC PRESSURE (VENT APPLICATIONS)
BAR
.12
.09
.06
.03
0
24-HR CUSTOMER SERVICE: (800) 466-7873 16
Hydrophobic PTFE Media Vent Capsule Filter
• Composed of a pleated hydrophobic PTFE filter membrane rated at 0.02 µm absolutefor small volume storage tank venting applications
• Convenient threaded inlet, with 1/2" NPTM inlet fitting screws into 1/2" NPTF bulkhead fitting, eliminates the need for a filter housing
• Hydrophobic expanded PTFE membranes are fully validated by bacterial challenge(HIMA)
• Filters feature thermally-bonded polypropylene cage without using adhesives to ensure low extractables
• 100% integrity tested in manufacturing and can be repeatedly autoclaved with steamup to 140°C
CARTRIDGE SPECIFICATIONSDimensions
Diameter (OD) . . . . . . . . . . 2.2" (5.6 cm)Length (in) . . . . . . . . . . . . 5.9 (15 cm)Inner Connection . . . . . . . . 1⁄2" MNPT
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene Media . . . . . . . . . . . . . . . . PTFE Membrane
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . Ambient AirMaximum Differential Pressure @ 23°C. . . . . 60 psi (4.1 bar)Air Filtration Rating. . . . . . . . . . . . . . . . . . . . 0.02 µm 100% AbsoluteToxicity . . . . . . . . . . . . . . . . . . . . . . . . . . . . Non-toxic by USP Class VI Biological test for plastics
Sanitizing Agents
Chlorine, Hydrogen Peroxide
ORDERING INFORMATIONCatalog Number and Description
FCVPTO6S1 Capsule Hydrophobic PTFE Filter
NOTE: These filter cartridges should not be used as a combination air vent/wateroverflow device.
Pres
sure
Dro
p (PS
ID) 4.0
5.0
3.0
1.0
2.0
8 16 24 32Air Flow (SCFM)
BAR
.35
.28
.21
.07
.14
0
250 500 750 1000SLPM
AIR FLOW RATES AT NEAR ATMOSPHERIC PRESSURE (VENT APPLICATIONS)
TECHNICAL SUPPORT (800) 875-7873 EXT. 5000 17
UF Series Hollow Fiber Polysulfone Media Filter Cartridge
CARTRIDGE SPECIFICATIONSDimensions
Diameter (OD) . . . . . . . . . . 2.9" (7.4 cm)Length (in) . . . . . . . . . . . . 10, 20, 30, 40
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene caps and cage, polyurethane end sealantMedia . . . . . . . . . . . . . . . . Polysulfone fibersSeals . . . . . . . . . . . . . . . . . Silicone o-rings
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . 185°F (85°C) @ 10 psid (.7 bar)Maximum Differential Pressure . . . . . . . . . . . 30 psi (2 bar) @ 25°CFiltration Rating . . . . . . . . . . . . . . . . . . . . . . 100% AbsoluteToxicity . . . . . . . . . . . . . . . . . . . . . . . . . . . . Non-toxic by USP Class VI Biological test for plasticsValidation . . . . . . . . . . . . . . . . . . . . . . . . . . Diffusive flow test methods
Recommended Water Flow Rates
0.05 micron . . . . . . . . . . . . 2.0 gpm/10" length (7.6 lpm/10" length)0.1 and 0.2 micron. . . . . . . 3.0 gpm/10" length (11.4 lpm/10" length)
Sanitizing Agents
Chlorine, hydrogen peroxide, autoclaved for 20 minutes at 121°C under no load conditions
ORDERING INFORMATIONCatalog Number and Description
FCUF . . . . . . . . . . . . . . . . . Filter cartridge ultra filter
X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear end1 = double open end w/internal o-rings7 = 2-226 o-rings w/locking tabs/spear end
XX . . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30, 40 = 40
XX(X) . . . . . . . . . . . . . . . Micron Rating: S05 = 0.05 µm, S1 = 0.1 µm, S2 = 0.2 µm
To figure your order number, replace the X with one of the numbered or lettered optionsbeside it. Note: Not all part number combinations are available; consult TechnicalSupport for assistance.
• Composed of validatable hollow fiber pleated polysulfone media with polypropylene hardware
• These absolute rated filters offer excellent bacteria and particle and pyrogen removal for critical pharmaceutical and life science applications, at economical costs
• Code 0, Code 5, and Code 7 configurations are available in 10, 20, 30 and 40-inlengths
• Meet current USP Class VI biological test for plastics, with a validation certificate available
• Contain no surfactants or coatings to interfere with your application, and thermo-plastic construction process minimizes extractables
• Hollow fiber construction ensures strength, while exhibiting low pressure drop and exceptionally high flow rates
Clean
Pre
ssure
Dro
p (PS
ID)
BAR
Water Flow Rate/10" Cartridge (GPM)
2
4
6
8
10
12
0.5
.1
.10
.20
2 4 6
2 4 6
0
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP
LPM
0.05 µm 0.1 µm
0.2 µm
24-HR CUSTOMER SERVICE: (800) 466-7873 18
Point-of-Use High Purity WaterFiltration Capsule Filters
CARTRIDGE SPECIFICATIONSModel Number 500 1000
DimensionsFiltration Area . . . . . . . . . . . . . . . . . 500 cm2 1000 cm2
Diameter (OD) . . . . . . . . . . . . . . . . . 2.7" (6.8 cm) 2.7" (6.8 cm)Length/in (cm). . . . . . . . . . . . . . . . . 4.8" (12.2) 6.7" (16.9)
Materials
Cartridge . . . . . . . . . . . . . Polypropylene caps, core and cageMedia . . . . . . . . . . . . . . . . Pleated polyethersulfone
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . 140° F (60° C) @ 30 psid (2.1 bar)Maximum Op Pressure . . . . . . . . . . . . . . . . . 60 psid (4.1bar) @ 20° CMaximum Momentary Pressure . . . . . . . . . . . 100 psid (7.0 bar) @ 20° CFiltration Rating . . . . . . . . . . . . . . . . . . . . . . 100% AbsoluteToxicity . . . . . . . . . . . . . . . . . . . . . . . . . . . . Non-toxic by USP Class VI Biological test for plasticsValidation . . . . . . . . . . . . . . . . . . . . . . . . . . HIMA Bacterial challenge test methods (107 organisms/cm2)
Recommended Water Flow Rates
Model Number 500 10000.1 µm. . . . . . . . . . . . . . . . . . . . 0.04 gpm (0.16 lpm) 0.1 gpm (0.38 lpm)0.2 µm. . . . . . . . . . . . . . . . . . . . 0.1 gpm (0.38 lpm) 0.3 gpm (1.1 lpm)
Integrity TestPore Size: Minimum Water Bubble Point
0.1 µm . . . . . . . . . . . . . . . . . ≥ 90 psig (≥ 6.2 bar) ≥ 90 psig (≥ 6.2 bar)0.2 µm . . . . . . . . . . . . . . . . . ≥ 45 psig (≥ 3.1 bar) ≥ 45 psig (≥ 3.1 bar)
Pore Size: Diffusional Flow (cc/min)0.1 µm . . . . . . . . . . . . . . . . . ≤ 4.0 cc/min at 50 psi (3.4 bar) <6.0 cc/min at 50 psi (3.4 bar)0.2 µm . . . . . . . . . . . . . . . . . ≤ 4.0 cc/min at 40 psi (2.8 bar) <6.0 cc/min at 40 psi (2.8 bar)
Sanitizing Agents
Hydrogen peroxide or autoclaved for 20 minutes at 121°C
ORDERING INFORMATIONCatalog Number and Description
FCCF . . . . . . . . . . . . . . . . . Capsule filter
X . . . . . . . . . . . . . . . . . . . Effective filter area: P = 1000 cm2 electronics gradeH = 500 cm2 pharmaceutical gradeE = 500 cm2 electronics grade
X . . . . . . . . . . . . . . . . . . . Inlet fitting: 1 = 1/4" NPTM, 2 = 1/2" NPTM
X . . . . . . . . . . . . . . . . . . . Outlet fitting: 1 = 1/4" hose barb, 2 = 1/4" NPTM, 3 = 1/2" NPTM, 4 = 1/2" hose barb w/filling bell
XX . . . . . . . . . . . . . . . . . . Micron rating: S1 = 0.1µm, S2 = 0.2 µm
• Designed to provide absolute final filtration after laboratory water purification productsor standard service deionization systems
• All polypropylene shell and support materials provide a non-pyrogenic filter, based onUSP and LAL testing
• Microporous membrane is made from hydrophilic polyethersulfone, providing a bacteria retentive filter based on Pseudomonous diminuta challenge (HIMA)
• Integrity tested and validatable, making them ideal for microelectronic andpharmaceutical applications
• Disposable housings are fusion welded without adhesives to ensure low extractables
TECHNICAL SUPPORT (800) 875-7873 EXT. 5000 19
Pulverized Activated Carbon Filter Cartridge
CARTRIDGE SPECIFICATIONSDimensions 10" Cartridge 20" Cartridge
Diameter (OD) . . . . . . . . . . 2.75" (7.0 cm) 2.75" (7.0 cm)Length (in) . . . . . . . . . . . . 9.75" (24.8 cm) 20" (50.8 cm)
Recommended Water Flow Rates
Maximum . . . . . . . . . . . . . 1.0 gpm (3.8 lpm) 2.0 gpm (7.6 lpm)
Materials
Primary filter media . . . . . . . . . . . . . . . . . . . Pulverized, Activated CarbonInner Layer Media . . . . . . . . . . . . . . . . . . . . Alpha Cellulose and Synthetic FibersInner Core . . . . . . . . . . . . . . . . . . . . . . . . . . PolypropyleneOuter Netting . . . . . . . . . . . . . . . . . . . . . . . . PolyolefinEnd Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . Low Durometer Polyethylene
Operating Parameters
Temperature Range . . . . . . 32 to 125°F (0 – 52°C)
Carbon Volume
3.7 ounces of pulverized carbon per 10" length
ORDERING INFORMATIONCatalog Number and Description
FCPC . . . . . . . . . . . . . . . . . Filter cartridge pulverized carbon
F. . . . . . . . . . . . . . . . . . . . Cartridge Code: F = double open end w/flat gasket seal
XX . . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20
10. . . . . . . . . . . . . . . . . . . Nominal micron retention rating
To figure your order number, replace the X with one of the numbered orlettered options beside it.
• Composed of pre-washed, finely pulverized activated carbon, encapsulated in a depthfiltration media of highly purified alpha-cellulose and synthetic fibers for removingchlorine
• Depth-type cartridge ensures superior dirt holding capacity in sediment-laden waters to minimize premature exhaustion while it is being carbon treated
• Design includes a thermally bonded outer, nominal 10 micron pre-filtration layer thatprovides for depth filtration in one pass without carbon channeling or media migration
24-HR CUSTOMER SERVICE: (800) 466-7873 20
Granular Activated Carbon Filter Cartridge
• Composed of lignite-based granular activated carbon in an upflow cartridge design for removing chlorine feedwaters
• Cartridge is designed to allow water to enter the bottom of the cartridge, then filteredthrough the entire carbon bed before exiting at the top to maximize the contact time andtherefore the adsorption
• Internal expansion pad maintains a tight, compact column to minimize channeling or bypass
• Nominal 20 micron post-filter reduces carbon fines as well as other suspended particles
CARTRIDGE SPECIFICATIONSDimensions 10" Cartridge 20" Cartridge
Diameter (OD) . . . . . . . . . . 2.875" (7.3 cm) 2.875" (7.3 cm)Length (in) . . . . . . . . . . . . 9.75" (24.8 cm) 20" (50.8 cm)
Recommended Water Flow Rates
10" Cartridge Maximum . . . 1.0 gpm (3.8 lpm) 2.0 gpm (7.6 lpm)
Materials
Filter Media . . . . . . . . . . . . . . . . . . . . . . . . . Granular, Activated CarbonPost filter. . . . . . . . . . . . . . . . . . . . . . . . . . . Spun PolypropyleneExpansion Pad Foam. . . . . . . . . . . . . . . . . . . Polyther/PolyurethaneOuter Casing . . . . . . . . . . . . . . . . . . . . . . . . PolystyreneEnd Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . PolystyreneGaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . Buna-N
Operating Parameters
Temperature Range . . . . . . 32 to 125°F (0 – 52°C)
Carbon Volume
12 ounces of granular carbon per 10" length
ORDERING INFORMATIONCatalog Number and Description
FCGC . . . . . . . . . . . . . . . . . Filter cartridge granular carbon
F. . . . . . . . . . . . . . . . . . . . Cartridge Code: F = flat gasket seal
XX . . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20
20. . . . . . . . . . . . . . . . . . . Nominal micron retention rating
To figure your order number, replace the X with one of the numbered orlettered options beside it.
TECHNICAL SUPPORT (800) 875-7873 EXT. 5000 21
316 Stainless Steel, Single-TubeFilter Housing
FILTER HOUSING SPECIFICATIONSDimensions
Length (A) Width (B)
10-in Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.5" (34.3 cm) 4.75 (12.1 cm)20-in Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23.5" (59.7 cm) 4.75 (12.1 cm)30-in Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33.5" (85.1 cm) 4.75 (12.1 cm)
Materials
Bowl and Head. . . . . . . . . . . . . . . . . . . . . . . 316 stainless steelPort Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . 316 stainless steelO-ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ethylene Propylene
Operating Parameters
Max Operating Pressure . . . . . . . . . . . . . . . . 175 psi (12.1 bar) @ 200°F (93°C)Max Housing Flow Rate. . . . . . . . . . . . . . . . . 12 gpm (45.4 lpm)Note: Housing rating only, safe operating pressure will depend on filter cartridge and gaskets used.
Connections
Inlet/Outlet . . . . . . . . . . . . . . . . . . . . . . . . . 3/4" NPTDrain. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4" NPT
Mounting
Should be mounted by rigid pipe connections or with optional mounting bracket. Allow enough clearancebelow bottom of housing to allow cartridge to be changed.
Flow Direction
“Inlet” and “Outlet” are cast on the housing head for user convenience.
ORDERING INFORMATIONCatalog Number and Description
ZHDFD1001 10" housing
ZHDFD2001 20" housing
ZHDFD3001 30" housing
ZHDXDB001 Mounting Bracket
This single-tube cartridge filter housing is made of cast 316 stainless steel and includes 316 stainless steel shell. Housings are available to accommodate 10, 20 or 30-in Code Ffilter cartridges. The inlet and outlet are 3/4" NPT, and the bowl of each housing is fittedwith a 1/4" NPT drain and vent plug. This cartridge filter housing is ideal for a wide varietyof low flow applications requiring a high quality prefilter housing or for applications wherean industrial pre-filter is used.
• Single tube housings accomodate 10", 20" and 30" Code F filter cartridges
• Housing uses 316SS for construction of the head, bowl and port plug
• Inlet and outlet connections are made to the housing head, allowing cartridges to bereplaced without disconnecting the inlet/outlet piping
• Housing can be autoclaved or hot-water sanitized with the cartridges in place for your convenience
Pres
sure
Dro
p (PS
ID)
1614
1012
2
864
0 15105 20 25 30Water Flow Rate (GPM)
HOUSING PRESSURE DROP vs. LIQUID FLOW RATE
24-HR CUSTOMER SERVICE: (800) 466-7873 22
316L Stainless Steel, Single-TubeFilter Housing
SYSTEM SPECIFICATIONSDimensions
Length (A) Width (B)10-in Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.8" (37.5 cm) 4.2 (10.5 cm)20-in Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24.8" (62.9 cm) 4.2 (10.5 cm)30-in Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34.8" (88.4 cm) 4.2 (10.5 cm)
Materials
Head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316L stainless steelBowl and Plugs. . . . . . . . . . . . . . . . . . . . . . . 316 stainless steelO-ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EPDM
Surface Finish
Head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sand Blasted Finish Cartridge Sealing Surface . . . . . . . . . . . . . . . 32 RMS FinishBowl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Satin Finish
Operating Parameters
Max Inlet Pressure . . . . . . . . . . . . . . . . . . . . 175 psi (12.1 bar) @ 150°F(66°C)Note: Housing rating only, safe operating pressure will depend on filter cartridge and gaskets used.
Connections
Inlet/Outlet . . . . . . . . . . . . . . . . . . . . . . . . . 3/4" NPTDrain and Vent . . . . . . . . . . . . . . . . . . . . . . . 1/4" NPT
Mounting
Should be mounted by rigid pipe connections or optional mounting bracket. Allow enough clearance below bottomof housing to allow cartridge to be changed.
Flow Direction“Inlet” and “Outlet” are electroetched on the housing head for user convenience.
ORDERING INFORMATIONCatalog Number and Description
ZHD0D1001 10" housing
ZHD0D2001 20" housing
ZHD0D3001 30" housing
ZHDXDB001 Mounting Bracket
This single-tube cartridge filter housing is made of 316L stainless steel and includes 316 stainless steel port plugs. Housings are available to accommodate 10, 20 or 30-in Code 0filter cartridges. The inlet and outlet are 3/4" NPT, and the bowl of each housing is fittedwith a 1/4" NPT drain and vent plug. This cartridge filter housing is ideal for a widevariety of low flow applications requiring a high quality prefilter housing or for applicationswhere an industrial pre-filter is used.
• Inlet and outlet connections are made to the housing head, allowing cartridges to bereplaced without disconnecting the inlet/outlet piping
• Bowl incorporates a satin finish to help prevent bacterial build-up
• Housing can be autoclaved or hot-water sanitized with the cartridges in place for your convenience
• Two vent ports are included in the head for venting, or for the installation of pressuregauges
Pres
sure
Dro
p (PS
ID)
20
15
5
10
0 5 10 15 20 25 30Water Flow Rate (GPM)
HOUSING PRESSURE DROP vs. LIQUID FLOW RATE
TECHNICAL SUPPORT (800) 875-7873 EXT. 5000 23
304 Stainless Steel, Multi-Tube Filter Housingwith V-Clamp Closure
This multi-tube cartridge filter housing is made of durable 304 stainless steel, and is suitedfor general-purpose industrial and commercial filtration. These housings can accommodate Code F (DOE), Code 0 or Code 5 cartridges.
• Incorporates a flow baffle, which deflects incoming flow to prevent cartridge erosion.
• A 1/4" NPT air vent on the cover allows venting before start-up.
• A 3/4" NPT drain plug allows for liquid removal.
• Cartridges are independently sealed inside the housing and a single V-band clamp housingclosure allows easy cartridge replacement.
• Cartridge post can be lifted out, allowing easy removal of cartridges at the bottom of the stack.
FILTER HOUSING SPECIFICATIONSCartridge Inlet/Outlet Housing Dimensions/Inches (cm) Flange Opt. Max. FlowHousing Inches (cm) A B C D E Rate*/gpm (lpm)
5-round 10" 1-1/2 NPTM (3.8) 25 (64) 11.5 (29) 5.5 (14) 12 (30) 12.75 (32) 25 (94.6)5-round 20" 1-1/2 NPTM (3.8) 32.5 (85) 11.5 (29) 5.5 (14) 12 (30) 12.75 (32) 50 (189)5-round 30" 2 NPTM (5.1) 44 (112) 11.5 (29) 5.5 (14) 12 (30) 12.75 (32) 75 (284)5-round 40" 2 NPTM (5.1) 54.5 (138) 11.5 (29) 5.5 (14) 12 (30) 12.75 (32) 100 (378)
Materials
Head, Shell, Plugs. . . . . . . . . . . . . . . . . . . . . 304 Stainless SteelInternals . . . . . . . . . . . . . . . . . . . . . . . . . . . 316 Stainless SteelCover O-Ring . . . . . . . . . . . . . . . . . . . . . . . . Ethylene PropyleneHold Down Plate Nut. . . . . . . . . . . . . . . . . . . Polypropylene
Operating Parameters
Maximum Operating Pressure . . . . . . . . . . . . 150 psi (10.7 bar) @ 200°F (93°C)Maximum Housing Flow Rates* . . . . . . . . . . . 100 gpm (378 lpm)
*Housing rating only, cartridge length and type will effect maximum flow rates
ORDERING INFORMATIONCatalog Number Description Inlet/Outlet
ZHFFI0510 5-round 10" 1-1/2” NPT
ZHFFI0520 5-round 20" 1-1/2” NPT
ZHFFI0530 5-round 30" 2” NPT
ZHFFI0540 5-round 40" 2” NPT
ZHFFI0510F 5-round 10" 1-1/2” Flange
ZHFFI0520F 5-round 20" 1-1/2” Flange
ZHFFI0530F 5-round 30" 2” Flange
ZHFFI0540F 5-round 40" 2” Flange
**Flange inlet and outlet are also available; add F Suffix to part number
Outlet
Drain
Nameplate
Tank Assembly
Wing Nut
"Warning" Decal
OptionalFlange
SeparatorSeat Plate
Inlet
O-Ring
Tie Rod
Vent
Cover Assembly
V-ClampNut
Pres
sure
Dro
p (PS
ID)
4.0
2.5
3.0
3.5
2.0
0.5
1.0
1.5
0 20 40 60 80 100 120 140Water Flow Rate (GPM)
1.5" Connection
2" Connection
HOUSING PRESSURE DROP vs. LIQUID FLOW RATE
24-HR CUSTOMER SERVICE: (800) 466-7873 24
304 Stainless Steel, Multi-TubeFilter Housing with Swing Bolt Closure
This multi-tube cartridge filter housing is made of 18 gauge 304 stainless steel. Housingsare available to accommodate six, 10, 20, 30 or 40-in, Code F filter cartridges. The inletand outlet are 2" NPT. There is a 1/2" NPT drain plug, and a 1/4" NPT vent at the topof the housing. A swing bolt closure allows quick disassembly for cleaning and service.This cartridge filter housing is ideal for a wide variety of high flow applications thatrequire an economical, high quality housing.
• Uses 304 stainless steel construction for maximum corrosion resistance to deliver years of dependable service
• A swing bolt closure allows quick disassembly for cleaning and service
• An air vent plug on the cover allows venting before start-up
• This housing accommodates liquid flow rates up to 180 gpm (681 Lpm) with operating pressures to 150 psig (10.3 bar)
FILTER HOUSING SPECIFICATIONSCartridge Housing Dimensions/Inches (cm) Flange Option Max. FlowHousing A B C D E Rate*/gpm (lpm)
6-round 10" 24 (61) 11.2 (28) 5.2 (13) 10.2 (26) 15 (38) 30 (114)6-round 20" 34 (86) 11.2 (28) 5.2 (13) 10.2 (26) 15 (38) 60 (227)6-round 30" 45 (114) 11.2 (28) 5.2 (13) 10.2 (26) 15 (38) 90 (340)6-round 40" 56 (142) 11.2 (28) 5.2 (13) 10.2 (26) 15 (38) 120 (454)
Materials
Head and Shell . . . . . . . . . . . . . . . . . . . . . . . 304 Stainless SteelVent and Drain Plug . . . . . . . . . . . . . . . . . . . 304 Stainless Steel Seat Cups. . . . . . . . . . . . . . . . . . . . . . . . . . . 316L Stainless SteelO-Ring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ethylene Propylene
Operating Parameters
Maximum Operating Pressure . . . . . . . . . . . . 150 psi (10.3 bar) @ 200°F (93°C)Max Water Flow Rate* . . . . . . . . . . . . . . . . . 120 gpm (454 Lpm)
*Housing rating only, cartridge length and type will effect maximum flow rates
ORDERING INFORMATIONCatalog Number Description Inlet/Outlet
ZHGAF0610 6-round 10" 2" NPT
ZHGAF0620 6-round 20" 2" NPT
ZHGAF0630 6-round 30" 2" NPT
ZHGAF0640 6-round 40" 2" NPT
ZHGAF0610F 6-round 10" 2" flange
ZHGAF0620F 6-round 20" 2" flange
ZHGAF0630F 6-round 30" 2" flange
ZHGAF0640F 6-round 40" 2" flange
120.
00
Vent
Head
O-ring
Outlet
InletDrain
SpacerCartridge
ShellTube Guide
Bottom Seat Plate
CompressionSeat Plate Assembly
Swing Bolt Assembly
A
D
E
B
C
120.
00
Pres
sure
Dro
p (PS
ID)
10.0
8.0
6.0
2.0
4.0
0 30 60 90 120 150 190Water Flow Rate (GPM)
HOUSING PRESSURE DROP vs. LIQUID FLOW RATE
TECHNICAL SUPPORT (800) 875-7873 EXT. 5000 25
316 Stainless Steel, Multi-Tube Filter Housing
This multi-tube cartridge filter housing ismade of 316 stainless steel, and is suited forgeneral-purpose industrial and commercialfiltration. These housings can accommodateCode F (DOE) cartridges, and are availablewith 6, 12, and 21 tubes in 10, 20, 30, 40-inch lengths.
• Incorporates a flow baffle, which deflectsincoming flow to prevent cartridge erosion.
• An air vent on the cover allows ventingbefore start-up.
• A swing boot closure allows quick disassembly for cleaning and cartridge replacement
FILTER HOUSING SPECIFICATIONSDimensions Inlet/Outlet Housing Dimensions Flange Option Max. Flow(inches (cm) A B C D E Rate*/gpm (lpm)
6-round 10” 2 NPTM (5.1) 24 (61) 11.2 (28) 5.2 (13) 10.2 (26) 15 (38) 30 (114)6-round 20” 2 NPTM (5.1) 34 (86) 11.2 (28) 5.2 (13) 10.2 (26) 15 (38) 60 (227)6-round 30” 2 NPTM (5.1) 45 (114) 11.2 (28) 5.2 (13) 10.2 (26) 15 (38) 90 (340)6-round 40” 2 NPTM (5.1) 56 (142) 11.2 (28) 5.2 (13) 10.2 (26) 15 (38) 120 (454)12-round 30” 3 flange (7.6) 56 (142) 31 (79) 12 (30) 12 (30) 16.4 (42) 180 (680)12-round 40” 3 flange (7.6) 66 (168) 31 (79) 12 (30) 12 (30) 16.4 (42) 240 (908)21-round 30” 4 flange (10.16) 57 (145) 31 (79) 12 (30) 16 (41) 20.8 (53) 315 (1190)21-round 40” 4 flange (10.16) 67 (170) 31 (79) 12 (30) 16 (41) 20.8 (53) 420 (1560)
Materials
Head, Shell, Plugs . . . . . . 316L Stainless SteelInternals . . . . . . . . . . . . 316 Stainless SteelCover O-Ring . . . . . . . . . EDPM
Maximum Operating Pressure
6-Round. . . . . . . . . . . . . 150 psi (10.3 bar) @ 200°C (93°F)12-Round. . . . . . . . . . . . 150 psi (10.3 bar) @ 200°C (93°F)21-Round. . . . . . . . . . . . 150 psi (10.3 bar) @ 200°C (93°F)
ORDERING INFORMATIONCatalog Number Description Inlet/Outlet
ZHGOF610 6-round 10" 2" NPT
ZHGOF620 6-round 20" 2" NPT
ZHGOF630 6-round 30" 2" NPT
ZHGOF640 6-round 40" 2" NPT
ZHGOF610F 6-round 10" 2" flange
ZHGOF620F 6-round 20" 2" flange
ZHGOF630F 6-round 30" 2" flange
ZHGOF640F 6-round 40" 2" flange
ZHFFI1230 12-round 30" 3" flange
ZHFFI1240 12-round 40" 3" flange
ZHFFI2130 21-round 30" 4" flange
ZHFFI2140 21-round 40" 4" flange
*Housing rating only, cartridge length and type will effect maximum flow rates
Pres
sure
Dro
p (PS
ID)
10
8
6
2
4
0 100 200 300 400Water Flow Rate (GPM)
12-round
21-round
HOUSING PRESSURE DROP vs. LIQUID FLOW RATE
Pres
sure
Dro
p (PS
ID)
10.0
8.0
6.0
2.0
4.0
0 30 60 90 120 150 190Water Flow Rate (GPM)
HOUSING PRESSURE DROP vs. LIQUID FLOW RATE
120.
00
Vent
Head
O-ring
Outlet
InletDrain
SpacerCartridge
ShellTube Guide
Bottom Seat Plate
CompressionSeat Plate Assembly
Swing Bolt Assembly
A
D
E
B
C
120.
00
6-ROUND DIMENSIONS
12- AND 21-ROUND DIMENSIONS
24-HR CUSTOMER SERVICE: (800) 466-7873 26
316L Electropolished Stainless Steel,Multi-Tube Filter Housing
This multi-tube cartridge filter housing is made of electropolished 316L stainless steel.Different housings are available to accommodate seven 10, 20, 30 of 40 inch, Code 5 orCode 0 filter cartridges with two 222 O-rings. The inlet and outlet are 2" NPTM, or optional2" flange, and the bottom of each housing is fitted with a 3/4" NPTF drain plug. A V-bandclamp closure allows cartridges to be changed quickly and easily. This cartridge filter housingis ideal for a wide variety of low flow applications requiring an economical yet high qualityprefilter housing or for applications where industrial membrane filtration is used.
• Housing uses electro-polished 316L stainless steel construction that is easy to clean and provides maximum corrosion resistance
• Predrilled support stand allows the housing to be secured to floor or some mounting surface
• Housing can also accommodate Code F (DOE) cartridges, with liquid flow rates of 150 gpm, and operating pressures to 150 psig
• A 1/4" NPTF air vent plug on the cover allows venting before start-up
FILTER HOUSING SPECIFICATIONSDimensions Inlet/Outlet Housing Dimensions Flange Option Max. Flow(inches (cm) A B C D E Rate*/gpm (lpm)
7-round 10" 2" NPTM (5.1) 25 (64) 11.5 (29) 5.5 (14) 12 (30) 12.8" (32) 35 (132)7-round 20" 2" NPTM (5.1) 33.5 (85) 11.5 (29) 5.5 (14) 12 (30) 12.8" (32) 70 (264)7-round 30" 2" NPTM (5.1) 44 (112) 11.5 (29) 5.5 (14) 12 (30) 12.8" (32) 105 (398)7-round 40" 2" NPTM (5.1) 54.5 (138) 11.5 (29) 5.5 (14) 12 (30) 12.8" (32) 140 (530)
Materials
Head and Shell . . . . . . . . . . . . . . . . . . . . . . . 316L Stainless Steel electropolishedVent and Drain Plug . . . . . . . . . . . . . . . . . . . 316 Stainless Steel Seat Cups. . . . . . . . . . . . . . . . . . . . . . . . . . . 316L Stainless SteelO-Ring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ethylene Propylene
Operating Parameters
Maximum Operating Pressure . . . . . . . . . . . . 150 psi (10.3 bar) @ 93°F (200°C)Maximum Water Flow Rate* . . . . . . . . . . . . . 140 gpm (528 Lpm)
*Housing rating only, cartridge length and type will effect maximum flow rates
ORDERING INFORMATIONCatalog Number Description Inlet/Outlet
ZHH000710 7-round 10" 2" NPTM
ZHH000720 7-round 20" 2" NPTM
ZHH000730 7-round 30" 2" NPTM
ZHH000740 7-round 40" 2" NPTM
ZHH000710F 7-round 10" 2" flange
ZHH000720F 7-round 20" 2" flange
ZHH000730F 7-round 30" 2" flange
ZHH000740F 7-round 40" 2" flange
Vent
Cover AssemblyTie Rod
Nut
O-Ring
Inlet
SeparatorSeat Plate
V-Clamp
Wing Nut
Tank Assembly
Nameplate
"Warning" Decal
Drain
Outlet
Pres
sure
Dro
p (PS
ID)
12
8
10
6
2
4
0 30 60 90 120 150 180 210Water Flow Rate (GPM)
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP
TECHNICAL SUPPORT (800) 875-7873 EXT. 5000 27
Plastic Filter Housings
FILTER HOUSING SPECIFICATIONSDimensions 10" Cartridge 20" Cartridge
Diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2" (13.2 cm) 5.2" (13.2 cm)Length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.2" (31 cm) 22.4" (57 cm)
Recommended Water Flow Rates
Maximum . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 gpm (30 lpm) 16 gpm (60 lpm)
Materials
Polypropylene cap and housing with standard BUNA-N o-rings
Operating Parameters
Maximum Operating Pressure . . . . . . . . . . . . . . . . . 125 psi (8.6 bar)Maximum Operating Temperature . . . . . . . . . . . . . . 100°F (38°C)Sterilization/Sanitization Hydrogen Peroxide . . . . . . . 7.5% compatibility; static soak up to 24 hr at ambient temperature
Weight
10" housing . . . . . . . . . . . . . . . . . . . . . . . . . 3 lb (1.4 kg)20" housing . . . . . . . . . . . . . . . . . . . . . . . . . 4.25 lb (1.9 kg)
Housing Compatibility/Cartridge Type
ZHCFA1001 . . . . . . . . . . . . . . . . . . . . . . . . . Code F, 9-3/4”ZHCFA2001 . . . . . . . . . . . . . . . . . . . . . . . . . Code F, 20”
ORDERING INFORMATIONCatalog Number and Description
ZHC Polypropylene filter housing
F Cartridge Code: F = Code F
A A = No plugs
XX Length (in): 10 = 10, 20 = 20
01 01 = 1 tube
ACCESSORIESCatalog Number and Description
ZHA150060 Mounting Bracket
These filter housings are molded from polypropylene, and are available in 10- and 20-inch lengths. Housings are supplied with 3/4" inlet and outlets in standard flat gasketdesign for Code F filter cartridges.
• Durable housings are made from all polypropylene materials
• Housings are autoclavable, ETO sterilizable, and hydrogen peroxide compatible
• Supplied with 3/4" NPT inlet and outlets in standard flat gasket design for Code Ffilter cartridges
24-HR CUSTOMER SERVICE: (800) 466-7873 28
FILTER HOUSING SPECIFICATIONSDimensions 10" Cartridge 20" Cartridge
Diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2" (13.2 cm) 5.2" (13.2 cm)Length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.2" (31 cm) 22.4" (57 cm)
Recommended Water Flow Rates 10" Cartridge 20" Cartridge
Maximum (Code 0 cartridge). . . . . . . . . . . . . . 4 gpm (15 lpm) 6 gpm (22.7 lpm)
Materials
Natural polypropylene cap and housing with standard Viton E-60 o-rings
Operating Parameters
Maximum Operating Pressure . . . . . . . . . . . . 100 psi (6.9 bar)Maximum Operating Temperature . . . . . . . . . 100°F (38°C)Sterilization/Sanitization
Autoclavable . . . . . . . . . . . . . . . . . . . . . 25 min 121–127°C (252–260°F)Hydrogen Peroxide . . . . . . . . . . . . . . . . 7.5% compatibility; static soak up to 24 hr at ambient temperature
Weight
10" housing . . . . . . . . . . . . . . . . . . . . . . . . . 3 lb (1.4 kg)12" housing . . . . . . . . . . . . . . . . . . . . . . . . . 3.5 lb (1.6 kg)20" housing . . . . . . . . . . . . . . . . . . . . . . . . . 4.25 lb (1.9 kg)
Housing Compatibility/Cartridge Type
ZHA0D1201* . . . . . . . . . . . . . . . . . . . . . . . . Code 0, 10"ZHA0D2001. . . . . . . . . . . . . . . . . . . . . . . . . Code 0, 20"ZHAFD1001 . . . . . . . . . . . . . . . . . . . . . . . . . Code F, 93⁄4"ZHAFD2001 . . . . . . . . . . . . . . . . . . . . . . . . . Code F, 20"
*Code 0, 10" cartridge must be used with 12" housing
ORDERING INFORMATION ACCESSORIESCatalog Number and Description Catalog Number and Description
ZHA Natural polypropylene filter housing ZHA150060 Mounting Bracket
X Cartridge Code: F = Code F, 0 = Code 0
D Cartridge Configuration: D = Double cap plug
XX Length: 10 = 10, 12 = 12, 20 = 20
01 Number of Tubes: 01 = 1 tube
To figure your order number, replace the X with one of the numbered/lettered options below it.
Natural Polypropylene Filter Housing
These filter housings are molded from natural, high-density polypropylene, and are availablein 10-, 12- and 20-inch lengths. Housings are molded in dies that are minutely polished foran ultra-smooth finish to all contact surfaces, thus minimizing the opportunity for bacteriaadhesion. Housings are supplied with 3/4" inlet and outlets in standard flat gasket design forCode F filter cartridges, and 222 O-ring design for Code 0 filter cartridges. Heads areavailable with double cap plug design and viton O-rings.
• Durable housings are made from all polypropylene materials (except for O-rings)
• Housings contain no fillers, colorants, plasticizers, or lubricants
• Available in flat gasket design for Code F filter cartridges, and 222 O-ring design for Code 0 filter cartridges
• Housings are autoclavable and hydrogen peroxide compatible
• Supplied with 3/4" NPT inlet and outlets
A Total Solution from One Supplier: The USFilter Difference
USFIlter understands how important it is for your water treatment
equipment to operate reliably and economically. That’s why we offer
a wide range of high-quality, economical aftermarket products and
services worldwide to meet your needs. We help you stay ahead with
our full selection of products and services. From replacement parts to
upgrading an existing system, we provide total solutions to help
you manage your most challenging projects.
SERVICE DEIONIZATION (SDI)
WATER ANALYSIS/RESIN ANALYSIS
MAINTENANCE CONTRACTS
RESIN REGENERATION
MOBILE TREATMENT SYSTEMS
MEMBRANE CLEANING
WASTEWATER SERVICES
COMPLETE WATER SYSTEMS
LABORATORY SYSTEMS
ION EXCHANGE RESIN
REPLACEMENT PARTS
FILTER CARTRIDGES
FILTRATION MEDIA
RO MEMBRANES
OUR AFTERMARKET SERVICES AND PRODUCTS
Your USFilter sales representative is your single contact for any
components you require for your facility. In addition, that same
representative can arrange to have maintenance technicians
dispatched from one of our many local branches, should your system
ever require service.
North America Customer & Technical Service NetworkIn the Continental United States
800.466.7873 Customer Service 24-hour800.875.7873 ext. 5000 Technical Support
10 Technology DriveLowell, MA 01851
In CanadaUSFilter Canada East (Toronto)
905.890.2803 Customer Service 24-hour
USFilter Canada West (Calgary)403.250.2650 Customer Service 24-hour
or contact your local USFilter branch
http://www.usfilter.com©2001 USFilter
USFilter is ready to serve you quickly and efficiently with over 70
service centers and 5 distribution and regeneration plants nationwide.
In accordance with USFilter policy for continualproduct development and improvement, wereserve the right to change the productspecification within this literature at any time,without notice. USFilter, CDI®, are registeredtrademarks of United States Filter Corporation or an affiliated company.
Printed on recylced paper in the U.S.A. 2/01
Literature No.: LO-AF-CA-0101