case study - morocco solar system · thermal driven separation processes case study of memsys solar...

7
Thermal driven Separation Processes Case study of Memsys Solar Desalination System in Morocco Memsys Water Technologies GmbH Fuggerstraße 33, 86830 Schwabmünchen, Germany +49 (0) 823 2807 9549 +65 91011205 [email protected] [email protected]

Upload: others

Post on 26-Jan-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Thermal driven

Separation

Processes

Case study of Memsys Solar

Desalination System in Morocco

Memsys Water Technologies GmbH

Fuggerstraße 33, 86830 Schwabmünchen, Germany

+49 (0) 823 2807 9549

+65 91011205

[email protected]

[email protected]

2www.memsys.eu

Location and partner

Location: Ben Guerir, Moroco

Partner: Green energy park, Morocco,

http://www.greenenergypark.ma/

Memsys solar system

3www.memsys.eu

System layout

PV cells

� House�

4www.memsys.eu

Inside the “House”

RO system

with

pretreatment

Memsys

system

5www.memsys.eu

Memsys system

memsys

• 4 effect;

• 6.4 m2 membrane area;

• 20~50 l/h distillate water;

• Operating temperature 75~80 oC�

6www.memsys.eu

Process diagram

PV: 64 m2, 10 kW

MemsysRO

500 L

water

tank

Solar collector: 30

m2, 15 kW, 90 oC

RO brine,

1.5 m3/h

Product clean water,

7.8~8 m3/h

Final brine to discharge,

1~1.2 m3/h

Underground

water, 9 m3/h

0.3~0.5 m3/h7.5 m3/h

Container

(modified)

7www.memsys.eu

Operation data

• Solar heating temperature to

memsys is depended on the

weather;

• In a normal day in March, we can

get ave. 70 oC hot water to run

the MD system;

• The memsys system can produce

25~40 l/h distillate water;