5
Description / Application Compact, versatile, right or left horizontal position May be used in closet, utility room, or basement Construction Insulated steel cabinet Cabinet Finish No rust galvanized stucco finish CASED & UNCASED UPFLOW & DOWNFLOW EVAPORATOR COILS U/UC SERIES 02/03 Standard Finish Fully insulated cabinet on cased coils Equipped with a check flowrator for heat pump and cooling unit operation No rust high temperature thermoplastic drain pans for upflow and downflow application with secondary drain Accessories Downflow kit (DFK) used for all multi-position furnaces for downflow applications Made in the USA by: Goodman Manufacturing Company, L.P. 2550 North Loop West, Suite 400 Houston, TX 77092 www.goodmanmfg.com SS-208D Rev. M ®

Upload: vuongxuyen

Post on 17-May-2018

237 views

Category:

Documents


2 download

TRANSCRIPT

1

Description / Application• Compact, versatile, right or left horizontal position• May be used in closet, utility room, or basement

Construction• Insulated steel cabinet

Cabinet Finish• No rust galvanized stucco finish

CASED & UNCASEDUPFLOW & DOWNFLOWEVAPORATOR COILS

U/UC SERIES 02/03

Standard Finish• Fully insulated cabinet on cased coils• Equipped with a check flowrator for heat pump and

cooling unit operation• No rust high temperature thermoplastic drain pans for

upflow and downflow application with secondary drain

Accessories• Downflow kit (DFK) used for all multi-position

furnaces for downflow applications

Made in the USA by:Goodman Manufacturing Company, L.P.

2550 North Loop West, Suite 400Houston, TX 77092

www.goodmanmfg.com

SS-208DRev. M

®

2

UNCASED UPFLOW EVAPORATOR COILSUC-18 THRU UC-42, UC-47, UC-49, UC-59, & UC-62

SUCTIONCONNECTION

LIQUIDCONNECTION

“A” SHAPEDSLAB

3/4” FEMALE NPTPRIMARY & SECONDARY

DRAIN CONNECTIONS(IMPORTANT: HAND

TIGHTEN)

SUCTIONCONNECTION

LIQUIDCONNECTION

3/4”FEMALENPT PRIMARY &SECONDARYDRAINCONNECTIONS(IMPORTANT:HAND TIGHTEN)

ACCESS PANEL VIEW

UC-60 & UC-61ACCESS PANEL VIEW

NOTES:1) SEE BACK SHEET FOR INSTALLATION TIPS.2) DO NOT USE THIS COIL ON OIL FURNACES OR ANY APPLICATIONS WHERE THE TEMPERATURE ON DRAIN PAN MAY EXCEED 300°F. USE

THE FOLLOWING METAL DRAIN PANS: 15236-18 (U-18 THRU U-32), 15236-19 (U-36 THRU U-47), 15236-20 (U/UC-60 THRU U-61), AND FIELDFABRICATED METAL PAN FOR (U/UC-49, U/UC-59, AND U/UC-62).

3) * UC-29 COMES WITH 2 TON FLOWRATER B13134-59. IF 2-1/2 TON MATCHING IS REQUIRED, INSTALL PROVIDED PISTON KIT B17898-65.

STATICA B C PRESSURE

WET COIL

UC-18 1 1/2 13 14 1/4 20 1/8 650 0.20 2 3/8 5/8 14

UC-29 *2 - 21/2 13 14 20 1/8 900 0.20 2 3/8 3/4 16

UC-32 2 1/2 13 17 7/8 20 1/8 1000 0.30 3 3/8 3/4 24

UC-35 3 13 18 1/4 20 1/8 1200 0.30 2 3/8 3/4 18

UC-36 3 17 17 1/2 20 1/8 1200 0.25 2 3/8 3/4 19

UC-42 3 1/2 17 17 3/4 20 1/8 1400 0.30 3 3/8 3/4 34

UC-47 4 17 22 1/8 20 1/8 1600 0.30 3 3/8 7/8 31

UC-49 4 19 3/4 21 7/8 20 1/8 1600 0.30 3 3/8 7/8 33

UC-59 5 19 3/4 25 7/8 20 1/8 2000 0.30 3 3/8 7/8 36

UC-60 5 20 1/4 21 1/4 23 2000 0.30 3 3/8 7/8 42

UC-61 5 20 1/4 22 23 2000 0.30 4 3/8 7/8 44

UC-62 5 19 3/4 26 1/8 20 1/8 2000 0.30 4 3/8 7/8 47

SPECIFICATIONS

NOMINALCFM

NOMINALTONS

COILMODEL

DIMENSIONS (INCHES)

LIQUIDCONN.

NO.ROWS

SUCTIONCONN.

SHIPWT.

3

CASED UPFLOW EVAPORATOR COILSU-18 THRU U-42, U-47, U-49, U-59, & U-62

SUCTION LINE

LIQUID CONN.

3/4” FEMALE NPTPRIMARY &

SECONDARY DRAINCONNECTIONS

(IMPORTANT: HANDTIGHTEN)

23 3/8

SUCTION LINE

LIQUIDLINE

20 3/8

21 1/8

F

20 1/4

D

3/4” FEMALENPT PRIMARY &SECONDARYDRAIN CONNECTIONSIMPORTANT:HAND TIGHTEN

NOTE: FOR DRAIN PAN SPECIFICATIONS, REFER TO NOTE 2 ON PAGE 2.

1) * U-29 COMES WITH 2 TON FLOWRATOR B13134-59. IF 2 1/2 MATCHING IS REQUIRED, INSTALL PROVIDED PISTON KIT B17898-65.

ACCESS PANEL VIEW

ACCESS PANEL VIEW

U-60 & U-61

STATICA B C D E F PRESSURE

WET COIL

U-18 1 1/2 14 1/4 12 3/4 14 1/2 13 1/4 - 650 0.20 2 3/8 5/8 24

U-29 *2 - 21/2 14 1/4 12 3/4 14 1/2 13 1/4 - 900 0.20 2 3/8 3/4 26

U-30 2 1/2 18 1/4 17 1/4 16 1/2 17 1/4 - 1000 0.30 2 3/8 3/4 33

U-31 2 1/2 14 1/4 12 3/4 14 1/2 13 1/4 - 1000 0.30 3 3/8 3/4 30

U-32 2 1/2 18 1/4 17 1/4 16 1/2 17 1/4 2 1000 0.25 3 3/8 3/4 41

U-35 3 14 1/4 12 1/4 14 1/2 13 1/4 4 1/8 1200 0.30 2 3/8 3/4 29

U-36 3 18 1/4 17 1/4 16 1/2 17 1/4 1 3/4 1200 0.30 2 3/8 3/4 40

U-42 3 1/2 18 1/4 17 1/4 16 1/2 17 1/4 2 1400 0.30 3 3/8 3/4 48

U-47 4 18 1/4 17 1/4 16 1/2 17 1/4 6 1600 0.30 3 3/8 7/8 50

U-49 4 21 1/8 20 1/8 27 1/2 20 - 1600 0.30 3 3/8 7/8 51

U-59 5 21 1/8 20 1/8 27 1/2 20 - 2000 0.30 3 3/8 7/8 54

U-60 5 24 1/4 23 1/8 20 1/2 1/2 20 1/8 1 2000 0.30 3 3/8 7/8 60

U-61 5 24 1/4 23 1/8 20 1/2 1/2 20 1/8 1 5/8 2000 0.30 4 3/8 7/8 62

U-62 5 21 1/8 20 1/8 27 1/2 20 - 2000 0.30 4 3/8 7/8 68

LIQUIDCONN.

SUCTIONCONN.

SHIPWT.

SPECIFICATIONSDIMENSIONS (INCHES)

NOMINALTONS

COILMODEL

NOMINALCFM

NO.ROWS

4

STATIC PRESSURE DROP ACROSS COILAir Flow Data - Static Pressure Drop Across Coil - Upflow Application

DOWNFLOW APPLICATIONS

NOTE:A. Do not use this coil on oil furnaces or any applications where the temperature on drain pan may exceed 300°F. Use the following metal

drain pans: 15236-18 (U-18 thru U-32), 15236-19 (U-36 thru U-47), and 15236-20 (U/UC-60 thru U-61).B. Due to the rating mix/match of various coils with outdoor units it is important to match the furnace air flow for the total system capacity.

(Refer to furnace spec. sheet & condenser/heat pump spec. sheet.)

UC COIL INSTALLATION RECOMMENDATIONSMINIMUM DISTANCE

BETWEEN FURNACE AND COIL PAN = 2”

COIL MODEL AIR QUANTITY (CFM)

CFM 400 500 600 700 800 900.00 1000 1100

U18/UC18 WET 0.10 0.12 0.18 0.25 __ __ __ __

DRY 0.08 0.10 0.12 0.19 __ __ __ __

U29/UC29 CFM 600 700 800 900 1000 1100 1200 1300

/30 WET 0.12 0.16 0.20 0.25 0.30 __ __ __

DRY 0.08 0.10 0.13 0.16 0.21 __ __ __

U32/UC32 CFM 700 800 900 1000 1100 1200 1300 1400

U31 WET 0.16 0.22 0.24 0.28 0.34 __ __ __

DRY 0.10 0.16 0.18 0.24 0.27 __ __ __

U36/UC36 CFM 800 900 1000 1100 1200 1300 1400 1500

U35/UC35 WET 0.13 0.16 0.20 0.24 0.28 0.30 __ __

DRY 0.10 0.12 0.14 0.18 0.24 0.28 __ __

U42/UC42 CFM 900 1000 1100 1200 1300 1400 1500 1600

U47/UC47 WET 0.12 0.16 0.20 0.24 0.27 0.30 0.34 __

DRY 0.10 0.13 0.15 0.18 0.20 0.22 0.26 __

CFM 1200 1300 1400 1500 1600 1700 1800 1900

U49/UC49 WET 0.14 0.18 0.22 0.26 0.30 0.34 __ __

DRY 0.12 0.14 0.17 0.19 0.22 0.26 __ __

U59/UC59 CFM 1600 1700 1800 1900 2000 2100 2200 2300

U60/UC60 WET 0.17 0.21 0.24 0.27 0.30 0.33 0.36 0.40

DRY 0.13 0.14 0.19 0.22 0.25 0.29 0.32 0.36

U61/UC61 CFM 1600 1700 1800 1900 2000 2100 2200 2300

U62/UC62 WET 0.19 0.22 0.26 0.29 0.32 0.36 0.40 0.45

DRY 0.15 0.17 0.21 0.25 0.28 0.32 0.35 0.39

5

(1) Utilizing factory installed bottom cabinet filler plates.(2) Discard bottom cabinet filler plates(3) Downflow Coil Adapter Kit allows use of U coils in downflow applications.(*) Upflow Application only(ND) Not for Downflow

CASED (U) COIL APPLICATION OPTIONS

GMP050-3 GDT045-3 GMP075-3 GDT090-4 GMP100-5 GDT115-5 GMP150-5

GMP050-32(C) GDT070-3 GMP100-3 GMNT080-4 GMP125-4 GMNT100-4 GMP150-52(C)

GMP075-3 GMNT040-3 GMP100-4 GPD100-4 GMP125-5 GPD125-4 GMPH120-5

GMP075-32(C) GMNT060-3 GMP100-42(C) GMP125-52(C) GMPN120-5

GMPH050-3 GPD050-3 GMPE075-3 GMPE100-4 GMT140-5 (ND)

GMPN040-3 GPD075-3 GMPH075-4 GMPE125-5

GMPN060-3 GMPN080-4 GMPH080-5

GMT045-3 (ND) GMT070-4 (ND) GMPN100-4

GMT070-3 (ND) GMT090-3 (ND) GMT090-5 (ND)

GMTH045-3 (ND) GMT090-4 (ND) GMT115-5 (ND)

GSM060-3 (ND) GMTH070-4 (ND) GMTH115-5 (ND)

GSMS060-3 (ND) GSM080-4 (ND) GSM100-4 (ND)

GSU060-3 (*) GSMS080-4 (ND) GSMS100-4 (ND)

GSU080-4 (*) GSU100-4 (*)

DFKT-17

COIL NOMINAL MODEL COIL

NO. WIDTHU-18 14” X XU-29 14” X XU-30 17 1/2” X(1) X(1) X(2) X(2)U-31 14” X XU-32 17 1/2” X(1) X(1) X(2) X(2)U-35 14” X XU-36 17 1/2” X(1) X(1) X(2) X(2)U-42 17 1/2” X(1) X(1) X(2) X(2)U-47 17 1/2” X XU-49 21” X(1) X(1) X(2) X(2)U-59 21” X(1) X(1) X(2) X(2)U-60 24 1/2” X(1) X(1) X(2) X(2)U-61 24 1/2” X(1) X(1) X(2) X(2)U-62 21” X(1) X(1) X(2) X(2)

FURNACE MODEL

NO.

NOMINAL FURNACE WIDTH

DFK MODEL NO. (3)

24 1/2”

DFK - 14 DFKT-14 DFK - 17 DFK - 21 DFKT - 21 DFK – 24 DFKT – 24

GMNT120-5

14” 14” 17 1/2” 17 1/2” 21” 21” 24 1/2”

Quality Makes the Difference!All of our systems are designed and manufactured with the same high quality standards regardless of size of efficiency. Ourdesigns virtually eliminate the most frequent causes of product failure. They are simple to service and forgiving to operate. We usethe highest quality materials and components available because if a part fails then the unit fails. Finally, every unit is run testedbefore it leaves the factory. That’s why we know...

There’s No Better Quality.

Visit our website at www.goodmanmfg.com for information on:• Goodman Products• Warranties• Customer Services• Parts• Contractor Programs and Training• Financing Options

NOTE: SPECIFICATIONS AND PERFORMANCE DATA LISTED HEREIN ARE SUBJECT TO CHANGE WITHOUT NOTICE