  • CASSETTEAIR CONDITIONERS

  • LG Cassette Air ConditionersDiscreet and versatile - LG Cassette Air Conditioners are Ideal for various applications including restaurants, hotels and offices.

    Compact SizeThe indoor unit is compact, enabling easier installation in smaller, more restricted spaces.

    KEY FEATURES

    High Ceiling ModeHigh ceiling mode provides powerful cooling and heating up to 4.2m in height, from ceiling to floor.

    160 161

    COM

    MERC

    IAL

    Length Width : 840 x 840mm

    Standard Inverter Height7.1 ~ 8.0kW 204mm

    10.0kW 246mm

    12.5 ~ 15kW 288mm

    (mm

    )

    11

    22

    2.4

    2.7 3

    4

    4.2

    101 22 33 44

    High Ceiling Mode

    General

    Compact Size Human detect sensor & humidity sensorThe indoor unit with slim and compact dimensions allows successful installation by easily accommodating it in various places of restricted area space.

    Motion sensors detect the activity of people per 20seconds

    Height 3.2 (15 x 8m) Height 3.5 (16 x 10m) A sensor is installed 90˚rotation12 × 6m 6 × 12m detecting

    High Ceiling ModeHigh ceiling mode provides powerful cooling and heating up to 4.2m in height, from ceiling to floor.

    • New 4 way cassette panel adapted unibody shape and matching with into the ceiling• Panel size is fit into the ceiling tile

    620 Panel – Compact and Stylish Design

    UnibodyShape

    (No Inlet Line)

    620mm

    620mm

    SINGLE SPLIT KEY FEATURES

    CEILING MOUNTED CASSETTE

    Apply human detection sensorApply vision sensor- Saving energy- Supply comfortable flow- Sensor is optional accessary

    only can be applied to PT-MCHW0

    Comfortable and Power Saving Control based on HumidityApply humidity sensor - Saving energy(To apply humidity sensor, new remote controller, PREMTB100 or PREMTBB10 is needed)

    20seconds

    Human detection sensor(PTVSMA0)

    • Detection

    • Detection range

    Length Width : 840 x 840mm

    Model HeightUTN24R 204mm

    UTN36R 288mm

    UTN48R 288mm

    160 161

    COM

    MERC

    IAL

    Length Width : 840 x 840mm

    Standard Inverter Height7.1 ~ 8.0kW 204mm

    10.0kW 246mm

    12.5 ~ 15kW 288mm

    (mm

    )

    11

    22

    2.4

    2.7 3

    4

    4.2

    101 22 33 44

    High Ceiling Mode

    General

    Compact Size Human detect sensor & humidity sensorThe indoor unit with slim and compact dimensions allows successful installation by easily accommodating it in various places of restricted area space.

    Motion sensors detect the activity of people per 20seconds

    Height 3.2 (15 x 8m) Height 3.5 (16 x 10m) A sensor is installed 90˚rotation12 × 6m 6 × 12m detecting

    High Ceiling ModeHigh ceiling mode provides powerful cooling and heating up to 4.2m in height, from ceiling to floor.

    • New 4 way cassette panel adapted unibody shape and matching with into the ceiling• Panel size is fit into the ceiling tile

    620 Panel – Compact and Stylish Design

    UnibodyShape

    (No Inlet Line)

    620mm

    620mm

    SINGLE SPLIT KEY FEATURES

    CEILING MOUNTED CASSETTE

    Apply human detection sensorApply vision sensor- Saving energy- Supply comfortable flow- Sensor is optional accessary

    only can be applied to PT-MCHW0

    Comfortable and Power Saving Control based on HumidityApply humidity sensor - Saving energy(To apply humidity sensor, new remote controller, PREMTB100 or PREMTBB10 is needed)

    20seconds

    Human detection sensor(PTVSMA0)

    • Detection

    • Detection range

    FasciaModel: PT-UMC1

    2 3LG Cassette Air Conditioners

    R32CEILING MOUNTED CASSETTEIndoor Unit Outdoor Unit

    Cooling Capacity (kW)

    Min ~ Rated ~ Max

    Heating Capacity (kW)

    Min ~ Rated ~ Max

    UTN24R UU24WR

    2.84 ~ 6.8 ~ 7.8 3.2 ~ 7.5 ~ 8.8

    UTN36R UU36WR

    4.5 ~ 9.5 ~ 13.0 5.0 ~ 10.8 ~ 13.7

    UTN48R UU48WR

    5.5 ~ 13.4 ~ 16.0 6.1 ~ 15.5 ~ 18.0

    MODEL LINE-UP

  • Wide Jet Air FlowImproved vanes reduce the curved area and provide even air distribution.

    Indirect Air FlowDirect Air Flow

    Independent Vane OperationThe independent vane operation feature uses separate motors, making it possible to control all four vanes independently.

    All Vane Operation Independent Vane Control

    162 163

    COM

    MERC

    IAL

    Wider

    567mm

    80mm

    487mm

    27°C

    15°C

    Air flow dead zonein 4 corners

    950/700 Panel – Wide Jet Air FlowImproved vanes reduce the curved area and provide even distribution.

    Convenient Panel InstallationThe detachable corner design makes it convenient to adjust the hanger during installation and to check for leakages in the drain connection pipe.

    Conventional

    27°C

    15°C

    Even air distribution

    LG Cassette

    * Wired remote controller PQRCVSL0 (QW) applied

    Indirect Air FlowDirect Air Flow

    Independent Vane OperationThe independent vane operation feature uses separate motors, making it possible to control all four vanes independently.

    All Vane Operation Independent Vane Control

    Attachable/detachable corner design

    RefrigantPiping check

    Hanger adjust

    Drain leakage check

    Hanger adjust

    Drain Leakage Check Hanger Adjust

    Drain leakage check

    Hanger adjust

    RefrigantPiping check

    Hanger adjust

    DetachableCorner Design

    Attachable/detachable corner design

    RefrigantPiping check

    Hanger adjust

    Drain leakage check

    Hanger adjust

    Drain Leakage Check Hanger Adjust

    Drain leakage check

    Hanger adjust

    RefrigantPiping check

    Hanger adjust

    DetachableCorner Design

    Drain leakage check and hanger adjust

    Hanger adjust

    Refrigerantpiping check and Hanger

    adjust

    Hanger adjust

    * Operating with wired remote controller PREMTB100, PREMTB001 and wireless remote controller included in PTEGM0.

    * Except CT09 NR2 / CT12 NR2 / CT18 NQ2* Applied to cassette panel PT-UMC1

    4-Point Support Structure Auto Leveling

    Auto Stop DetectionMemory for User’s Level

    Memory

    STOP Max.4.5m

    Detachable Corner Design Hanger AdjustDrain Leakage Check

    It is easy to attach the panel to the body, using the button type panel design

    Auto Elevation GrilleEasy filter cleaning by using the elevation grill.

    SINGLE SPLIT KEY FEATURES

    CEILING MOUNTED CASSETTE

    Conventional

    162 163

    COM

    MERC

    IAL

    Wider

    567mm

    80mm

    487mm

    27°C

    15°C

    Air flow dead zonein 4 corners

    950/700 Panel – Wide Jet Air FlowImproved vanes reduce the curved area and provide even distribution.

    Convenient Panel InstallationThe detachable corner design makes it convenient to adjust the hanger during installation and to check for leakages in the drain connection pipe.

    Conventional

    27°C

    15°C

    Even air distribution

    LG Cassette

    * Wired remote controller PQRCVSL0 (QW) applied

    Indirect Air FlowDirect Air Flow

    Independent Vane OperationThe independent vane operation feature uses separate motors, making it possible to control all four vanes independently.

    All Vane Operation Independent Vane Control

    Attachable/detachable corner design

    RefrigantPiping check

    Hanger adjust

    Drain leakage check

    Hanger adjust

    Drain Leakage Check Hanger Adjust

    Drain leakage check

    Hanger adjust

    RefrigantPiping check

    Hanger adjust

    DetachableCorner Design

    Attachable/detachable corner design

    RefrigantPiping check

    Hanger adjust

    Drain leakage check

    Hanger adjust

    Drain Leakage Check Hanger Adjust

    Drain leakage check

    Hanger adjust

    RefrigantPiping check

    Hanger adjust

    DetachableCorner Design

    Drain leakage check and hanger adjust

    Hanger adjust

    Refrigerantpiping check and Hanger

    adjust

    Hanger adjust

    * Operating with wired remote controller PREMTB100, PREMTB001 and wireless remote controller included in PTEGM0.

    * Except CT09 NR2 / CT12 NR2 / CT18 NQ2* Applied to cassette panel PT-UMC1

    4-Point Support Structure Auto Leveling

    Auto Stop DetectionMemory for User’s Level

    Memory

    STOP Max.4.5m

    Detachable Corner Design Hanger AdjustDrain Leakage Check

    It is easy to attach the panel to the body, using the button type panel design

    Auto Elevation GrilleEasy filter cleaning by using the elevation grill.

    SINGLE SPLIT KEY FEATURES

    CEILING MOUNTED CASSETTE

    Convenient Panel InstallationThe detachable corner design makes it convenient to adjust the hanger during installation and to check for leakages in the drain connection pipe.

    Drain leakage check and hanger adjust

    Hanger adjust

    Refrigerantpiping check and Hanger

    adjust

    Hanger adjust

    * Operating with wired remote controller PREMTB100, PREMTB001 and wireless remote controller included in PTEGM0.

    * Except CT09 NR2 / CT12 NR2 / CT18 NQ2* Applied to cassette panel PT-UMC1

    4-Point Support Structure Auto Leveling

    Auto Stop DetectionMemory for User’s Level

    Memory

    STOP Max.4.5m

    Detachable Corner Design Hanger AdjustDrain Leakage Check

    Auto Elevation GrilleEasy filter cleaning by using the elevation grill.

    162 163

    COM

    MERC

    IAL

    Wider

    567mm

    80mm

    487mm

    27°C

    15°C

    Air flow dead zonein 4 corners

    950/700 Panel – Wide Jet Air FlowImproved vanes reduce the curved area and provide even distribution.

    Convenient Panel InstallationThe detachable corner design makes it convenient to adjust the hanger during installation and to check for leakages in the drain connection pipe.

    Conventional

    27°C

    15°C

    Even air distribution

    LG Cassette

    * Wired remote controller PQRCVSL0 (QW) applied

    Indirect Air FlowDirect Air Flow

    Independent Vane OperationThe independent vane operation feature uses separate motors, making it possible to control all four vanes independently.

    All Vane Operation Independent Vane Control

    Attachable/detachable corner design

    RefrigantPiping check

    Hanger adjust

    Drain leakage check

    Hanger adjust

    Drain Leakage Check Hanger Adjust

    Drain leakage check

    Hanger adjust

    RefrigantPiping check

    Hanger adjust

    DetachableCorner Design

    Attachable/detachable corner design

    RefrigantPiping check

    Hanger adjust

    Drain leakage check

    Hanger adjust

    Drain Leakage Check Hanger Adjust

    Drain leakage check

    Hanger adjust

    RefrigantPiping check

    Hanger adjust

    DetachableCorner Design

    Drain leakage check and hanger adjust

    Hanger adjust

    Refrigerantpiping check and Hanger

    adjust

    Hanger adjust

    * Operating with wired remote controller PREMTB100, PREMTB001 and wireless remote controller included in PTEGM0.

    * Except CT09 NR2 / CT12 NR2 / CT18 NQ2* Applied to cassette panel PT-UMC1

    4-Point Support Structure Auto Leveling

    Auto Stop DetectionMemory for User’s Level

    Memory

    STOP Max.4.5m

    Detachable Corner Design Hanger AdjustDrain Leakage Check

    It is easy to attach the panel to the body, using the button type panel design

    Auto Elevation GrilleEasy filter cleaning by using the elevation grill.

    SINGLE SPLIT KEY FEATURES

    CEILING MOUNTED CASSETTE

    162 163

    COM

    MERC

    IAL

    Wider

    567mm

    80mm

    487mm

    27°C

    15°C

    Air flow dead zonein 4 corners

    950/700 Panel – Wide Jet Air FlowImproved vanes reduce the curved area and provide even distribution.

    Convenient Panel InstallationThe detachable corner design makes it convenient to adjust the hanger during installation and to check for leakages in the drain connection pipe.

    Conventional

    27°C

    15°C

    Even air distribution

    LG Cassette

    * Wired remote controller PQRCVSL0 (QW) applied

    Indirect Air FlowDirect Air Flow

    Independent Vane OperationThe independent vane operation feature uses separate motors, making it possible to control all four vanes independently.

    All Vane Operation Independent Vane Control

    Attachable/detachable corner design

    RefrigantPiping check

    Hanger adjust

    Drain leakage check

    Hanger adjust

    Drain Leakage Check Hanger Adjust

    Drain leakage check

    Hanger adjust

    RefrigantPiping check

    Hanger adjust

    DetachableCorner Design

    Attachable/detachable corner design

    RefrigantPiping check

    Hanger adjust

    Drain leakage check

    Hanger adjust

    Drain Leakage Check Hanger Adjust

    Drain leakage check

    Hanger adjust

    RefrigantPiping check

    Hanger adjust

    DetachableCorner Design

    Drain leakage check and hanger adjust

    Hanger adjust

    Refrigerantpiping check and Hanger

    adjust

    Hanger adjust

    * Operating with wired remote controller PREMTB100, PREMTB001 and wireless remote controller included in PTEGM0.

    * Except CT09 NR2 / CT12 NR2 / CT18 NQ2* Applied to cassette panel PT-UMC1

    4-Point Support Structure Auto Leveling

    Auto Stop DetectionMemory for User’s Level

    Memory

    STOP Max.4.5m

    Detachable Corner Design Hanger AdjustDrain Leakage Check

    It is easy to attach the panel to the body, using the button type panel design

    Auto Elevation GrilleEasy filter cleaning by using the elevation grill.

    SINGLE SPLIT KEY FEATURES

    CEILING MOUNTED CASSETTE

    162 163

    COM

    MERC

    IAL

    Wider

    567mm

    80mm

    487mm

    27°C

    15°C

    Air flow dead zonein 4 corners

    950/700 Panel – Wide Jet Air FlowImproved vanes reduce the curved area and provide even distribution.

    Convenient Panel InstallationThe detachable corner design makes it convenient to adjust the hanger during installation and to check for leakages in the drain connection pipe.

    Conventional

    27°C

    15°C

    Even air distribution

    LG Cassette

    * Wired remote controller PQRCVSL0 (QW) applied

    Indirect Air FlowDirect Air Flow

    Independent Vane OperationThe independent vane operation feature uses separate motors, making it possible to control all four vanes independently.

    All Vane Operation Independent Vane Control

    Attachable/detachable corner design

    RefrigantPiping check

    Hanger adjust

    Drain leakage check

    Hanger adjust

    Drain Leakage Check Hanger Adjust

    Drain leakage check

    Hanger adjust

    RefrigantPiping check

    Hanger adjust

    DetachableCorner Design

    Attachable/detachable corner design

    RefrigantPiping check

    Hanger adjust

    Drain leakage check

    Hanger adjust

    Drain Leakage Check Hanger Adjust

    Drain leakage check

    Hanger adjust

    RefrigantPiping check

    Hanger adjust

    DetachableCorner Design

    Drain leakage check and hanger adjust

    Hanger adjust

    Refrigerantpiping check and Hanger

    adjust

    Hanger adjust

    * Operating with wired remote controller PREMTB100, PREMTB001 and wireless remote controller included in PTEGM0.

    * Except CT09 NR2 / CT12 NR2 / CT18 NQ2* Applied to cassette panel PT-UMC1

    4-Point Support Structure Auto Leveling

    Auto Stop DetectionMemory for User’s Level

    Memory

    STOP Max.4.5m

    Detachable Corner Design Hanger AdjustDrain Leakage Check

    It is easy to attach the panel to the body, using the button type panel design

    Auto Elevation GrilleEasy filter cleaning by using the elevation grill.

    SINGLE SPLIT KEY FEATURES

    CEILING MOUNTED CASSETTEKEY FEATURES

    Model: PT-UMC1

    4 5LG Cassette Air Conditioners

  • Quiet Operation with 3D Fan3D fan is applied to H-Inverter cassettes 10 ~ 14kW. It increases air flow but reduces noise.

    * Standard Inverter 10kW

    4dB (A)

    New ModelPrevious Model

    43dB (A)

    47dB(A)

    Prevent Ceiling PollutionCoanda design of air outlet can help prevent contamination of ceiling.

    Previous Model Coanda Design

    164 165

    COM

    MERC

    IALQuiet Operation with 3D Fan

    New technology of 3D fan is applied to H-Inverter cassettes 10 ~ 14kW. It increases air flow but reduces noise.

    Blade Angle Changed : Increase air flow and decrease noise

    Curved Leading Edge : Improve air flow in same RPM of conventional fans

    Conventional

    New

    * Standard Inverter 10kW

    4dB (A)

    NewConventional

    43dB (A)

    47dB(A)

    CeilingCeiling

    CeilingPollutions

    ProductLouver

    ProductLouver

    CeilingCeiling

    CeilingPollutions

    ProductLouver

    ProductLouver

    Prevent Ceiling PollutionCoanda design of air outlet can prevent contamination of ceiling.

    Conventional Coanda Design

    Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Definition of Power Input Nominal conditions – Performance tested under EN14511 3. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB / 19°C WB - Outdoor Temperature 35°C DB / 24°C WB Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB 4. Annual energy consumption : based on average use of 350 running hours in cooling and 1,400 hours in heating per year at seasonal condition 5. This product contains fluorinated greenhouse gases (R32)

    INDOOR CT09R NR0 CT12R NR0 CT18R NQ0 CT24R NP0

    Capacity Cooling Min / Nom / Max kW 1.0 / 2.5 / 2.8 1.4 / 3.4 / 3.9 2.0 / 5.0 / 5.7 2.84 / 6.8 / 7.8Heating Min / Nom / Max kW 1.2 / 3.2 / 3.4 1.6 / 4.0 / 4.6 2.2 / 5.8 / 6.8 3.2 / 8.0 / 8.8

    Low Temperature Capacity Heating -7°C Max kW 2.7 3.6 4.9 7.2

    Power Input (Set)Cooling Nom kW 0.63 0.97 1.56 1.94 Heating Nom kW 0.75 1.12 1.66 2.00

    Power Input (Indoor) Min / Nom / Max W 10 / 20 / 20 10 / 20 / 20 10 / 30 / 40 20 / 50 / 60Running Current Cooling / Heating Nom A 2.7 / 3.5 4.3 / 5.0 7.1 / 7.5 8.6 / 8.8Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50EER 4.00 3.51 3.21 3.51COP 4.00 3.58 3.49 4.00SEER 6.77 6.58 6.25 7.70SCOP 4.36 4.40 4.25 4.60Pdesign (@-10°C) kW 3.0 3.0 4.1 5.8 Seasonal Energy Label Cooling / Heating A++ / A+ A++ / A+ A++ / A+ A++ / A+Annual Energy Consumption Cooling / Heating kWh 129 / 963 181 / 955 280 / 1,351 309 / 1,765

    Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 9.52 (3/8)Gas mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2) Ø 15.88 (5/8)Drain O.D. / I.D. mm 32 / 25 32 / 25 32 / 25 32 / 25

    Air Flow Rate High / Medium / Low m3/min 8.5 / 7.0 / 6.0 9.5 / 8.0 / 7.0 13.0 / 12.0 / 11.0 17.0 / 15.0 / 13.0Sound Pressure Cooling High / Medium / Low dBA 36 / 33 / 30 38 / 35 / 32 41 / 39 / 36 38 / 36 / 34Sound Power Cooling Max dBA 52 52 57 57Dehumidification Rate l/h 0.9 1.4 2.0 2.7Dimensions Body W x H x D mm 570 x 214 x 570 570 x 214 x 570 570 x 256 x 570 840 x 204 x 840Net Weight Body kg 14.0 14.0 14.3 20.5

    Decoration Panel

    Model PT-QCHW0 PT-QCHW0 PT-QCHW0 PT-MCHW0Color Morning Fog Morning Fog Morning Fog Morning FogDimensions W x H x D mm 620 x 20 x 620 620 x 20 x 620 620 x 20 x 620 950 x 25 x 950Weight kg 3.0 3.0 3.0 6.3

    OUTDOOR UU09WR UL0 UU12WR UL0 UU18WR U20 UU24WR U40Compressor Type Twin Rotary Twin Rotary Twin Rotary Twin RotaryAirflow Rate Nom m3/min 32 32 50 58

    Sound PressureCooling Nom dBA 47 49 47 48Heating Nom dBA 50 52 52 52

    Sound Power Cooling Max dBA 65 65 63 67Dimensions W x H x D mm 770 x 545 x 288 770 x 545 x 288 870 x 650 x 330 950 x 834 x 330Net Weight kg 33.8 33.8 44.8 56.1

    Refrigerant

    Type R32 R32 R32 R32Charge g 900 900 1,100 1,600Additional Charge (after 7.5m) g/m 20 20 20 35GWP 675 675 675 675t-CO2 eq 0.61 0.61 0.74 1.08

    Operation Range (Outdoor)Cooling Min ~ Max °C DB -15 ~ 48 -15 ~ 48 -15 ~ 48 -15 ~ 48Heating Min ~ Max °C WB -18 ~ 18 -18 ~ 18 -18 ~ 18 -18 ~ 18

    Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50Power Supply Cable No. x mm2 3C x 2.5 3C x 2.5 3C x 2.5 3C x 2.5Transmission Cable No. x mm2 4C x 0.75 4C x 0.75 4C x 0.75 4C x 0.75Circuit Breaker A 15 15 20 25Piping Length Total Min ~ Max m 5~20 5~20 5 ~ 30 5 ~ 50Piping Elevation Difference IDU - ODU Max m 15 15 30 30

    Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 9.52 (3/8)Gas mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2) Ø 15.88 (5/8)

    CT09RCT12RCT18RCT24R

    UU24WRUU09WRUU12WR

    UU18WR

    STANDARD INVERTER (R32)

    LG participates in the ECP programme for EUROVENT AC program.Check ongoing validity of certification : www.eurovent-certification.com

    SINGLE SPLIT KEY FEATURES

    CEILING MOUNTED CASSETTESINGLE SPLIT SPECIFICATION

    CEILING MOUNTED CASSETTE

    164 165

    COM

    MERC

    IALQuiet Operation with 3D Fan

    New technology of 3D fan is applied to H-Inverter cassettes 10 ~ 14kW. It increases air flow but reduces noise.

    Blade Angle Changed : Increase air flow and decrease noise

    Curved Leading Edge : Improve air flow in same RPM of conventional fans

    Conventional

    New

    * Standard Inverter 10kW

    4dB (A)

    NewConventional

    43dB (A)

    47dB(A)

    CeilingCeiling

    CeilingPollutions

    ProductLouver

    ProductLouver

    CeilingCeiling

    CeilingPollutions

    ProductLouver

    ProductLouver

    Prevent Ceiling PollutionCoanda design of air outlet can prevent contamination of ceiling.

    Conventional Coanda Design

    Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Definition of Power Input Nominal conditions – Performance tested under EN14511 3. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB / 19°C WB - Outdoor Temperature 35°C DB / 24°C WB Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB 4. Annual energy consumption : based on average use of 350 running hours in cooling and 1,400 hours in heating per year at seasonal condition 5. This product contains fluorinated greenhouse gases (R32)

    INDOOR CT09R NR0 CT12R NR0 CT18R NQ0 CT24R NP0

    Capacity Cooling Min / Nom / Max kW 1.0 / 2.5 / 2.8 1.4 / 3.4 / 3.9 2.0 / 5.0 / 5.7 2.84 / 6.8 / 7.8Heating Min / Nom / Max kW 1.2 / 3.2 / 3.4 1.6 / 4.0 / 4.6 2.2 / 5.8 / 6.8 3.2 / 8.0 / 8.8

    Low Temperature Capacity Heating -7°C Max kW 2.7 3.6 4.9 7.2

    Power Input (Set)Cooling Nom kW 0.63 0.97 1.56 1.94 Heating Nom kW 0.75 1.12 1.66 2.00

    Power Input (Indoor) Min / Nom / Max W 10 / 20 / 20 10 / 20 / 20 10 / 30 / 40 20 / 50 / 60Running Current Cooling / Heating Nom A 2.7 / 3.5 4.3 / 5.0 7.1 / 7.5 8.6 / 8.8Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50EER 4.00 3.51 3.21 3.51COP 4.00 3.58 3.49 4.00SEER 6.77 6.58 6.25 7.70SCOP 4.36 4.40 4.25 4.60Pdesign (@-10°C) kW 3.0 3.0 4.1 5.8 Seasonal Energy Label Cooling / Heating A++ / A+ A++ / A+ A++ / A+ A++ / A+Annual Energy Consumption Cooling / Heating kWh 129 / 963 181 / 955 280 / 1,351 309 / 1,765

    Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 9.52 (3/8)Gas mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2) Ø 15.88 (5/8)Drain O.D. / I.D. mm 32 / 25 32 / 25 32 / 25 32 / 25

    Air Flow Rate High / Medium / Low m3/min 8.5 / 7.0 / 6.0 9.5 / 8.0 / 7.0 13.0 / 12.0 / 11.0 17.0 / 15.0 / 13.0Sound Pressure Cooling High / Medium / Low dBA 36 / 33 / 30 38 / 35 / 32 41 / 39 / 36 38 / 36 / 34Sound Power Cooling Max dBA 52 52 57 57Dehumidification Rate l/h 0.9 1.4 2.0 2.7Dimensions Body W x H x D mm 570 x 214 x 570 570 x 214 x 570 570 x 256 x 570 840 x 204 x 840Net Weight Body kg 14.0 14.0 14.3 20.5

    Decoration Panel

    Model PT-QCHW0 PT-QCHW0 PT-QCHW0 PT-MCHW0Color Morning Fog Morning Fog Morning Fog Morning FogDimensions W x H x D mm 620 x 20 x 620 620 x 20 x 620 620 x 20 x 620 950 x 25 x 950Weight kg 3.0 3.0 3.0 6.3

    OUTDOOR UU09WR UL0 UU12WR UL0 UU18WR U20 UU24WR U40Compressor Type Twin Rotary Twin Rotary Twin Rotary Twin RotaryAirflow Rate Nom m3/min 32 32 50 58

    Sound PressureCooling Nom dBA 47 49 47 48Heating Nom dBA 50 52 52 52

    Sound Power Cooling Max dBA 65 65 63 67Dimensions W x H x D mm 770 x 545 x 288 770 x 545 x 288 870 x 650 x 330 950 x 834 x 330Net Weight kg 33.8 33.8 44.8 56.1

    Refrigerant

    Type R32 R32 R32 R32Charge g 900 900 1,100 1,600Additional Charge (after 7.5m) g/m 20 20 20 35GWP 675 675 675 675t-CO2 eq 0.61 0.61 0.74 1.08

    Operation Range (Outdoor)Cooling Min ~ Max °C DB -15 ~ 48 -15 ~ 48 -15 ~ 48 -15 ~ 48Heating Min ~ Max °C WB -18 ~ 18 -18 ~ 18 -18 ~ 18 -18 ~ 18

    Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50Power Supply Cable No. x mm2 3C x 2.5 3C x 2.5 3C x 2.5 3C x 2.5Transmission Cable No. x mm2 4C x 0.75 4C x 0.75 4C x 0.75 4C x 0.75Circuit Breaker A 15 15 20 25Piping Length Total Min ~ Max m 5~20 5~20 5 ~ 30 5 ~ 50Piping Elevation Difference IDU - ODU Max m 15 15 30 30

    Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 9.52 (3/8)Gas mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2) Ø 15.88 (5/8)

    CT09RCT12RCT18RCT24R

    UU24WRUU09WRUU12WR

    UU18WR

    STANDARD INVERTER (R32)

    LG participates in the ECP programme for EUROVENT AC program.Check ongoing validity of certification : www.eurovent-certification.com

    SINGLE SPLIT KEY FEATURES

    CEILING MOUNTED CASSETTESINGLE SPLIT SPECIFICATION

    CEILING MOUNTED CASSETTE

    164 165

    COM

    MERC

    IALQuiet Operation with 3D Fan

    New technology of 3D fan is applied to H-Inverter cassettes 10 ~ 14kW. It increases air flow but reduces noise.

    Blade Angle Changed : Increase air flow and decrease noise

    Curved Leading Edge : Improve air flow in same RPM of conventional fans

    Conventional

    New

    * Standard Inverter 10kW

    4dB (A)

    NewConventional

    43dB (A)

    47dB(A)

    CeilingCeiling

    CeilingPollutions

    ProductLouver

    ProductLouver

    CeilingCeiling

    CeilingPollutions

    ProductLouver

    ProductLouver

    Prevent Ceiling PollutionCoanda design of air outlet can prevent contamination of ceiling.

    Conventional Coanda Design

    Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Definition of Power Input Nominal conditions – Performance tested under EN14511 3. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB / 19°C WB - Outdoor Temperature 35°C DB / 24°C WB Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB 4. Annual energy consumption : based on average use of 350 running hours in cooling and 1,400 hours in heating per year at seasonal condition 5. This product contains fluorinated greenhouse gases (R32)

    INDOOR CT09R NR0 CT12R NR0 CT18R NQ0 CT24R NP0

    Capacity Cooling Min / Nom / Max kW 1.0 / 2.5 / 2.8 1.4 / 3.4 / 3.9 2.0 / 5.0 / 5.7 2.84 / 6.8 / 7.8Heating Min / Nom / Max kW 1.2 / 3.2 / 3.4 1.6 / 4.0 / 4.6 2.2 / 5.8 / 6.8 3.2 / 8.0 / 8.8

    Low Temperature Capacity Heating -7°C Max kW 2.7 3.6 4.9 7.2

    Power Input (Set)Cooling Nom kW 0.63 0.97 1.56 1.94 Heating Nom kW 0.75 1.12 1.66 2.00

    Power Input (Indoor) Min / Nom / Max W 10 / 20 / 20 10 / 20 / 20 10 / 30 / 40 20 / 50 / 60Running Current Cooling / Heating Nom A 2.7 / 3.5 4.3 / 5.0 7.1 / 7.5 8.6 / 8.8Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50EER 4.00 3.51 3.21 3.51COP 4.00 3.58 3.49 4.00SEER 6.77 6.58 6.25 7.70SCOP 4.36 4.40 4.25 4.60Pdesign (@-10°C) kW 3.0 3.0 4.1 5.8 Seasonal Energy Label Cooling / Heating A++ / A+ A++ / A+ A++ / A+ A++ / A+Annual Energy Consumption Cooling / Heating kWh 129 / 963 181 / 955 280 / 1,351 309 / 1,765

    Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 9.52 (3/8)Gas mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2) Ø 15.88 (5/8)Drain O.D. / I.D. mm 32 / 25 32 / 25 32 / 25 32 / 25

    Air Flow Rate High / Medium / Low m3/min 8.5 / 7.0 / 6.0 9.5 / 8.0 / 7.0 13.0 / 12.0 / 11.0 17.0 / 15.0 / 13.0Sound Pressure Cooling High / Medium / Low dBA 36 / 33 / 30 38 / 35 / 32 41 / 39 / 36 38 / 36 / 34Sound Power Cooling Max dBA 52 52 57 57Dehumidification Rate l/h 0.9 1.4 2.0 2.7Dimensions Body W x H x D mm 570 x 214 x 570 570 x 214 x 570 570 x 256 x 570 840 x 204 x 840Net Weight Body kg 14.0 14.0 14.3 20.5

    Decoration Panel

    Model PT-QCHW0 PT-QCHW0 PT-QCHW0 PT-MCHW0Color Morning Fog Morning Fog Morning Fog Morning FogDimensions W x H x D mm 620 x 20 x 620 620 x 20 x 620 620 x 20 x 620 950 x 25 x 950Weight kg 3.0 3.0 3.0 6.3

    OUTDOOR UU09WR UL0 UU12WR UL0 UU18WR U20 UU24WR U40Compressor Type Twin Rotary Twin Rotary Twin Rotary Twin RotaryAirflow Rate Nom m3/min 32 32 50 58

    Sound PressureCooling Nom dBA 47 49 47 48Heating Nom dBA 50 52 52 52

    Sound Power Cooling Max dBA 65 65 63 67Dimensions W x H x D mm 770 x 545 x 288 770 x 545 x 288 870 x 650 x 330 950 x 834 x 330Net Weight kg 33.8 33.8 44.8 56.1

    Refrigerant

    Type R32 R32 R32 R32Charge g 900 900 1,100 1,600Additional Charge (after 7.5m) g/m 20 20 20 35GWP 675 675 675 675t-CO2 eq 0.61 0.61 0.74 1.08

    Operation Range (Outdoor)Cooling Min ~ Max °C DB -15 ~ 48 -15 ~ 48 -15 ~ 48 -15 ~ 48Heating Min ~ Max °C WB -18 ~ 18 -18 ~ 18 -18 ~ 18 -18 ~ 18

    Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50Power Supply Cable No. x mm2 3C x 2.5 3C x 2.5 3C x 2.5 3C x 2.5Transmission Cable No. x mm2 4C x 0.75 4C x 0.75 4C x 0.75 4C x 0.75Circuit Breaker A 15 15 20 25Piping Length Total Min ~ Max m 5~20 5~20 5 ~ 30 5 ~ 50Piping Elevation Difference IDU - ODU Max m 15 15 30 30

    Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 9.52 (3/8)Gas mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2) Ø 15.88 (5/8)

    CT09RCT12RCT18RCT24R

    UU24WRUU09WRUU12WR

    UU18WR

    STANDARD INVERTER (R32)

    LG participates in the ECP programme for EUROVENT AC program.Check ongoing validity of certification : www.eurovent-certification.com

    SINGLE SPLIT KEY FEATURES

    CEILING MOUNTED CASSETTESINGLE SPLIT SPECIFICATION

    CEILING MOUNTED CASSETTE

    Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Definition of Power Input Nominal conditions – Performance tested under EN14511. 3. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB / 19°C WB - Outdoor Temperature 35°C DB / 24°C WB. Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB. 4. Annual energy consumption : based on average use of 350 running hours in cooling and 1,400 hours in heating per year at seasonal condition. 5. This product contains fluorinated greenhouse gases (R32). 6. Optional Fascia PT-UMC1.

    SPECIFICATIONS

    Indoor UnitUnit

    UTN24R UTN36R UTN48R

    Outdoor Unit UU24WR UU36WR UU48WR

    Rated CapacityCooling kW 6.80 9.50 13.40

    Heating kW 7.50 10.80 15.50

    Capacity RangeCooling Min ~ Max kW 2.84 ~ 7.8 4.5 ~ 13.0 5.5 ~ 16.0

    Heating Min ~ Max kW 3.2 ~ 8.3 5.0 ~ 13.7 6.1 ~ 18.0

    Rated Power InputCooling kW 1.95 2.47 4.27

    Heating kW 1.88 2.80 4.80

    AEER / ACOP Cooling / Heating - 3.461 / 3.969 3.769 / 3.788 3.113 / 3.207

    EER / COP Cooling / Heating - 3.487 / 4.000 3.846 / 3.857 3.138 / 3.229

    Rated Current Cooling / Heating A 8.60 / 8.80 10.7 / 12.2 18.9 / 21.0

    Max. Current (Full Load Amps)Indoor Unit A 0.6 1.0 1.0

    Set A 17 28 28

    Air Flow Rate L/s 283 / 250 / 216 500 / 416 / 333 550 / 466 / 366

    External Static Pressure Pa - - -

    Indoor

    Sound Level at 1.5m H / M / L Pressure dB(A) 38 / 36 / 34 46 / 43 / 40 47 / 44 / 41

    Dimensions W x H x D mm 840 x 204 x 840 840 x 288 x 840 840 x 288 x 840

    Weight kg 20.5 24.6 24.6

    Outdoor

    Sound Level at 1.5m Cooling / Heating Pressure dB(A) 48 / 52 52 / 54 52 / 54

    Sound Power Level dB(A) 67 66 68

    Dimensions W x H x D mm 950 x 834 x 330 950 x 1,380 x 330 950 x 1,380 x 330

    Weight kg 56.1 87.5 87.5

    Power Supply V / Phase / Hz 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50

    Circuir Breaker A 25 40 40

    Compressor Type - Twin Rotary LG Inverter Scroll LG Inverter Scroll

    RefrigerantType - R32 R32 R32

    Precharged Length m 7.5 7.5 7.5

    Pipe Sizes

    Liquid mm/inch ∅ ∅ 9.52 (3/8) ∅ ∅ 9.52 (3/8) ∅ ∅ 9.52 (3/8)

    Gas mm/inch ∅ ∅ 15.88 (5/8) ∅ ∅ 15.88 (5/8) ∅ ∅ 15.88 (5/8)

    Drain OD / ID mm ∅ ∅ 32 / 25 ∅ ∅ 32 / 25 ∅ ∅ 32 / 25

    Max. Pipe Length m 50 85 85

    Max. Height Difference ODU ~ IDU m 30 30 30

    Supply Air Opening H x W, Flange mm - - -

    Return Air Opening H x W, Flange mm - - -

    Continuous Operating RangeCooling °C DB - 15 ~ 48 - 15 ~ 48 - 15 ~ 48

    Heating °C WB - 18 ~ 18 - 18 ~ 18 - 18 ~ 18

    Demand Response - X X X

    UTN24R / UU24WRUTN36R / UU36WRUTN48R / UU48WR

    KEY FEATURES

    Model: UTN36WH2 Model: UTN36R

    Model: UTN36WH2

    6 7LG Cassette Air Conditioners

  • 8 9LG Cassette Air Conditioners

    CONTROLLERS & ACCESSORIES

    STANDARD CONTROLLER

    DELUXE CONTROLLERThe Deluxe Remote Controller is 4.3” with colour design and touch button. The easy to use touch button with backlit LCD displays temperature, humidity, allows you to control the temperature setting and can control up to 8 zones.

    • Set up to 8 zones• 4.3 inch colour display• Humidity sensor embedded• Touch button• Time display• Room temperature display• Room humidity display• Operation - On/Off• Mode - Auto/Cool/Dry/Heat/Fan• Occupied cooling and heating

    temperature setpoints

    The Premium Remote Controller is designed to suit even the most stylish interiors. The easy to use touchscreen panel with backlit LCD allows you to control the temperature with simplicity, and allows you to control up to 8 zones.

    • Set up to 8 zones• 5 inch colour display• Touch screen• Time display• Room temperature display • Operation - On/Off • Mode - Auto/Cool/Dry/Heat/Fan • Occupied cooling and heating

    temperature setpoints

    • Unoccupied cooling and heating temperature setpoints

    • Fan speed – Low/Med/High/Auto • Self diagnosis function• Auto restart on power failure• Sleep mode• Child lock• Energy monitor• Filter clean information• Weekly, yearly and holiday timer

    PREMIUM CONTROLLER

    • Unoccupied cooling and heating temperature setpoints

    • Fan speed - Low/Med/High/Auto• Time limit function• Auto restart on power failure• Sleep mode• Child lock• Energy monitor• Filter clean information• Dail, weekly, yearly and holiday timer

    The standard controller is compact and easy to use.

    • 4.3 inch mono display• Time display• Room temperature display • Operation - On/Off • Fan speed – Low/Med/High/Auto• Self diagnosis function

    • Auto restart on power failure• Sleep mode• Child lock• Filter clean information• Weekly timer

  • 10 11LG Cassette Air Conditioners

    ACCESSORIES

    Control Method Objective/Use Unit Name and Model Function Parts Features

    PI485

    PMNFP14A1

    To connect Outdoor unit to CNU or SimpleCentral Controller

    • RS485 Converter with software• For Max.16 Indoor

    • PCB Assembly• Bracket• Lead wire: 3ea• Screw 4EA• Tie wrap• Clamp• Manual

    • 1set/1 Outdoor

    Dry Contact

    PDRYCB100

    For connect Indoor unit to other Forced on/off Controller

    • RS485 Converter with software

    • PCB Assembly• Top case• Bottom case• Screw• Lead wire 3• Sub PCB set (1 leadwire + 1 sub PCB)• Manual

    • 1set/1 Indoor unit

    Dry Contact

    PDRYCB400

    For connect Indoor unit to other Forced on/off Controller

    • Contact signal to air-con signal converter

    • PCB Assembly• Top/Bottom case• Screw• Lead wire 3ea• Sub PCB set (1 leadwire + 1 sub PCB)• Manual

    • 1set/1 indoor unit• 2 Contact points• No need AC input• Expected temperature setting is possible

    *Dred/Dry contact.

    INTERFACE DEVICE

    OPTIONAL ACCESSORIES*Model Description

    PREMTB001 Standard Wired Wall Controller

    PREMTB100 Deluxe Wired Wall Controller

    PREMTA000 Premium Controller

    PWLSSB21H Wireless Remote Control

    PWFMDD200 WiFi Dongle + 1.1m Cable

    PWYREW000 10m Cable

    PT-UMC1 Cassette Fascia

    PTEGMO Auto Ellevation Grille

    *Refer to each model PDB for application accessories.

    Control Method Objective/Use Unit Name and Model Function Parts Features

    BNU-LW

    PLNWKB000

    To connect PI485 to LONWORKS BMS system

    • Interface between BMS and LG air-conditioners (LonMark certified : Operation system based on LNS)

    • Interface Assembly

    • 12V DC adaptor• Manual

    • 64 indoor units• ACP function (central controller) included

    BNU-BAC

    PQNFB17C 0

    To connect PI485 to BACnet BMS system

    • Interface between BMS and LG air-conditioners (BTL certified : Operation system based on BACnet service)

    • Interface Assembly• 12V DC adaptor• Manual

    • 256 Indoor units• ACP function (central controller) included• BTL certification (B-ASC)

    PDI STANDARD

    PPWRDB000

    To Power consumption Distribution of each indoor unit2-port

    • Accumulation of total power consumption• Indication of current power in use• Indication of accumulated power for period• Indication of standby power (option setting)

    • PDI Assembly Manual

    • 1 PDI / 2 Outdoor

    PDI Premium

    PQNUD1S40

    To power consumption distribution of each indoor unit8-port

    • Accumulation of total power consumption • Indication of current power in use• Indication of accumulated power for period • Indication of standby power• Blackout protection

    • PDI Assembly manual

    • 1 PDI / 8 Outdoor

    1) PI485 : Product Interface unit for RS 485 transmission

    BUILDING MANAGEMENT DEVICES

    ACCESSORIES

  • For more information visitlg.com/au/cassette February 2021