cassette...lg cassette air conditioners discreet and versatile - lg cassette air conditioners are...
TRANSCRIPT
-
CASSETTEAIR CONDITIONERS
-
LG Cassette Air ConditionersDiscreet and versatile - LG Cassette Air Conditioners are Ideal for various applications including restaurants, hotels and offices.
Compact SizeThe indoor unit is compact, enabling easier installation in smaller, more restricted spaces.
KEY FEATURES
High Ceiling ModeHigh ceiling mode provides powerful cooling and heating up to 4.2m in height, from ceiling to floor.
160 161
COM
MERC
IAL
Length Width : 840 x 840mm
Standard Inverter Height7.1 ~ 8.0kW 204mm
10.0kW 246mm
12.5 ~ 15kW 288mm
(mm
)
11
22
2.4
2.7 3
4
4.2
101 22 33 44
High Ceiling Mode
General
Compact Size Human detect sensor & humidity sensorThe indoor unit with slim and compact dimensions allows successful installation by easily accommodating it in various places of restricted area space.
Motion sensors detect the activity of people per 20seconds
Height 3.2 (15 x 8m) Height 3.5 (16 x 10m) A sensor is installed 90˚rotation12 × 6m 6 × 12m detecting
High Ceiling ModeHigh ceiling mode provides powerful cooling and heating up to 4.2m in height, from ceiling to floor.
• New 4 way cassette panel adapted unibody shape and matching with into the ceiling• Panel size is fit into the ceiling tile
620 Panel – Compact and Stylish Design
UnibodyShape
(No Inlet Line)
620mm
620mm
SINGLE SPLIT KEY FEATURES
CEILING MOUNTED CASSETTE
Apply human detection sensorApply vision sensor- Saving energy- Supply comfortable flow- Sensor is optional accessary
only can be applied to PT-MCHW0
Comfortable and Power Saving Control based on HumidityApply humidity sensor - Saving energy(To apply humidity sensor, new remote controller, PREMTB100 or PREMTBB10 is needed)
20seconds
Human detection sensor(PTVSMA0)
• Detection
• Detection range
Length Width : 840 x 840mm
Model HeightUTN24R 204mm
UTN36R 288mm
UTN48R 288mm
160 161
COM
MERC
IAL
Length Width : 840 x 840mm
Standard Inverter Height7.1 ~ 8.0kW 204mm
10.0kW 246mm
12.5 ~ 15kW 288mm
(mm
)
11
22
2.4
2.7 3
4
4.2
101 22 33 44
High Ceiling Mode
General
Compact Size Human detect sensor & humidity sensorThe indoor unit with slim and compact dimensions allows successful installation by easily accommodating it in various places of restricted area space.
Motion sensors detect the activity of people per 20seconds
Height 3.2 (15 x 8m) Height 3.5 (16 x 10m) A sensor is installed 90˚rotation12 × 6m 6 × 12m detecting
High Ceiling ModeHigh ceiling mode provides powerful cooling and heating up to 4.2m in height, from ceiling to floor.
• New 4 way cassette panel adapted unibody shape and matching with into the ceiling• Panel size is fit into the ceiling tile
620 Panel – Compact and Stylish Design
UnibodyShape
(No Inlet Line)
620mm
620mm
SINGLE SPLIT KEY FEATURES
CEILING MOUNTED CASSETTE
Apply human detection sensorApply vision sensor- Saving energy- Supply comfortable flow- Sensor is optional accessary
only can be applied to PT-MCHW0
Comfortable and Power Saving Control based on HumidityApply humidity sensor - Saving energy(To apply humidity sensor, new remote controller, PREMTB100 or PREMTBB10 is needed)
20seconds
Human detection sensor(PTVSMA0)
• Detection
• Detection range
FasciaModel: PT-UMC1
2 3LG Cassette Air Conditioners
R32CEILING MOUNTED CASSETTEIndoor Unit Outdoor Unit
Cooling Capacity (kW)
Min ~ Rated ~ Max
Heating Capacity (kW)
Min ~ Rated ~ Max
UTN24R UU24WR
2.84 ~ 6.8 ~ 7.8 3.2 ~ 7.5 ~ 8.8
UTN36R UU36WR
4.5 ~ 9.5 ~ 13.0 5.0 ~ 10.8 ~ 13.7
UTN48R UU48WR
5.5 ~ 13.4 ~ 16.0 6.1 ~ 15.5 ~ 18.0
MODEL LINE-UP
-
Wide Jet Air FlowImproved vanes reduce the curved area and provide even air distribution.
Indirect Air FlowDirect Air Flow
Independent Vane OperationThe independent vane operation feature uses separate motors, making it possible to control all four vanes independently.
All Vane Operation Independent Vane Control
162 163
COM
MERC
IAL
Wider
567mm
80mm
487mm
27°C
15°C
Air flow dead zonein 4 corners
950/700 Panel – Wide Jet Air FlowImproved vanes reduce the curved area and provide even distribution.
Convenient Panel InstallationThe detachable corner design makes it convenient to adjust the hanger during installation and to check for leakages in the drain connection pipe.
Conventional
27°C
15°C
Even air distribution
LG Cassette
* Wired remote controller PQRCVSL0 (QW) applied
Indirect Air FlowDirect Air Flow
Independent Vane OperationThe independent vane operation feature uses separate motors, making it possible to control all four vanes independently.
All Vane Operation Independent Vane Control
Attachable/detachable corner design
RefrigantPiping check
Hanger adjust
Drain leakage check
Hanger adjust
Drain Leakage Check Hanger Adjust
Drain leakage check
Hanger adjust
RefrigantPiping check
Hanger adjust
DetachableCorner Design
Attachable/detachable corner design
RefrigantPiping check
Hanger adjust
Drain leakage check
Hanger adjust
Drain Leakage Check Hanger Adjust
Drain leakage check
Hanger adjust
RefrigantPiping check
Hanger adjust
DetachableCorner Design
Drain leakage check and hanger adjust
Hanger adjust
Refrigerantpiping check and Hanger
adjust
Hanger adjust
* Operating with wired remote controller PREMTB100, PREMTB001 and wireless remote controller included in PTEGM0.
* Except CT09 NR2 / CT12 NR2 / CT18 NQ2* Applied to cassette panel PT-UMC1
4-Point Support Structure Auto Leveling
Auto Stop DetectionMemory for User’s Level
Memory
STOP Max.4.5m
Detachable Corner Design Hanger AdjustDrain Leakage Check
It is easy to attach the panel to the body, using the button type panel design
Auto Elevation GrilleEasy filter cleaning by using the elevation grill.
SINGLE SPLIT KEY FEATURES
CEILING MOUNTED CASSETTE
Conventional
162 163
COM
MERC
IAL
Wider
567mm
80mm
487mm
27°C
15°C
Air flow dead zonein 4 corners
950/700 Panel – Wide Jet Air FlowImproved vanes reduce the curved area and provide even distribution.
Convenient Panel InstallationThe detachable corner design makes it convenient to adjust the hanger during installation and to check for leakages in the drain connection pipe.
Conventional
27°C
15°C
Even air distribution
LG Cassette
* Wired remote controller PQRCVSL0 (QW) applied
Indirect Air FlowDirect Air Flow
Independent Vane OperationThe independent vane operation feature uses separate motors, making it possible to control all four vanes independently.
All Vane Operation Independent Vane Control
Attachable/detachable corner design
RefrigantPiping check
Hanger adjust
Drain leakage check
Hanger adjust
Drain Leakage Check Hanger Adjust
Drain leakage check
Hanger adjust
RefrigantPiping check
Hanger adjust
DetachableCorner Design
Attachable/detachable corner design
RefrigantPiping check
Hanger adjust
Drain leakage check
Hanger adjust
Drain Leakage Check Hanger Adjust
Drain leakage check
Hanger adjust
RefrigantPiping check
Hanger adjust
DetachableCorner Design
Drain leakage check and hanger adjust
Hanger adjust
Refrigerantpiping check and Hanger
adjust
Hanger adjust
* Operating with wired remote controller PREMTB100, PREMTB001 and wireless remote controller included in PTEGM0.
* Except CT09 NR2 / CT12 NR2 / CT18 NQ2* Applied to cassette panel PT-UMC1
4-Point Support Structure Auto Leveling
Auto Stop DetectionMemory for User’s Level
Memory
STOP Max.4.5m
Detachable Corner Design Hanger AdjustDrain Leakage Check
It is easy to attach the panel to the body, using the button type panel design
Auto Elevation GrilleEasy filter cleaning by using the elevation grill.
SINGLE SPLIT KEY FEATURES
CEILING MOUNTED CASSETTE
Convenient Panel InstallationThe detachable corner design makes it convenient to adjust the hanger during installation and to check for leakages in the drain connection pipe.
Drain leakage check and hanger adjust
Hanger adjust
Refrigerantpiping check and Hanger
adjust
Hanger adjust
* Operating with wired remote controller PREMTB100, PREMTB001 and wireless remote controller included in PTEGM0.
* Except CT09 NR2 / CT12 NR2 / CT18 NQ2* Applied to cassette panel PT-UMC1
4-Point Support Structure Auto Leveling
Auto Stop DetectionMemory for User’s Level
Memory
STOP Max.4.5m
Detachable Corner Design Hanger AdjustDrain Leakage Check
Auto Elevation GrilleEasy filter cleaning by using the elevation grill.
162 163
COM
MERC
IAL
Wider
567mm
80mm
487mm
27°C
15°C
Air flow dead zonein 4 corners
950/700 Panel – Wide Jet Air FlowImproved vanes reduce the curved area and provide even distribution.
Convenient Panel InstallationThe detachable corner design makes it convenient to adjust the hanger during installation and to check for leakages in the drain connection pipe.
Conventional
27°C
15°C
Even air distribution
LG Cassette
* Wired remote controller PQRCVSL0 (QW) applied
Indirect Air FlowDirect Air Flow
Independent Vane OperationThe independent vane operation feature uses separate motors, making it possible to control all four vanes independently.
All Vane Operation Independent Vane Control
Attachable/detachable corner design
RefrigantPiping check
Hanger adjust
Drain leakage check
Hanger adjust
Drain Leakage Check Hanger Adjust
Drain leakage check
Hanger adjust
RefrigantPiping check
Hanger adjust
DetachableCorner Design
Attachable/detachable corner design
RefrigantPiping check
Hanger adjust
Drain leakage check
Hanger adjust
Drain Leakage Check Hanger Adjust
Drain leakage check
Hanger adjust
RefrigantPiping check
Hanger adjust
DetachableCorner Design
Drain leakage check and hanger adjust
Hanger adjust
Refrigerantpiping check and Hanger
adjust
Hanger adjust
* Operating with wired remote controller PREMTB100, PREMTB001 and wireless remote controller included in PTEGM0.
* Except CT09 NR2 / CT12 NR2 / CT18 NQ2* Applied to cassette panel PT-UMC1
4-Point Support Structure Auto Leveling
Auto Stop DetectionMemory for User’s Level
Memory
STOP Max.4.5m
Detachable Corner Design Hanger AdjustDrain Leakage Check
It is easy to attach the panel to the body, using the button type panel design
Auto Elevation GrilleEasy filter cleaning by using the elevation grill.
SINGLE SPLIT KEY FEATURES
CEILING MOUNTED CASSETTE
162 163
COM
MERC
IAL
Wider
567mm
80mm
487mm
27°C
15°C
Air flow dead zonein 4 corners
950/700 Panel – Wide Jet Air FlowImproved vanes reduce the curved area and provide even distribution.
Convenient Panel InstallationThe detachable corner design makes it convenient to adjust the hanger during installation and to check for leakages in the drain connection pipe.
Conventional
27°C
15°C
Even air distribution
LG Cassette
* Wired remote controller PQRCVSL0 (QW) applied
Indirect Air FlowDirect Air Flow
Independent Vane OperationThe independent vane operation feature uses separate motors, making it possible to control all four vanes independently.
All Vane Operation Independent Vane Control
Attachable/detachable corner design
RefrigantPiping check
Hanger adjust
Drain leakage check
Hanger adjust
Drain Leakage Check Hanger Adjust
Drain leakage check
Hanger adjust
RefrigantPiping check
Hanger adjust
DetachableCorner Design
Attachable/detachable corner design
RefrigantPiping check
Hanger adjust
Drain leakage check
Hanger adjust
Drain Leakage Check Hanger Adjust
Drain leakage check
Hanger adjust
RefrigantPiping check
Hanger adjust
DetachableCorner Design
Drain leakage check and hanger adjust
Hanger adjust
Refrigerantpiping check and Hanger
adjust
Hanger adjust
* Operating with wired remote controller PREMTB100, PREMTB001 and wireless remote controller included in PTEGM0.
* Except CT09 NR2 / CT12 NR2 / CT18 NQ2* Applied to cassette panel PT-UMC1
4-Point Support Structure Auto Leveling
Auto Stop DetectionMemory for User’s Level
Memory
STOP Max.4.5m
Detachable Corner Design Hanger AdjustDrain Leakage Check
It is easy to attach the panel to the body, using the button type panel design
Auto Elevation GrilleEasy filter cleaning by using the elevation grill.
SINGLE SPLIT KEY FEATURES
CEILING MOUNTED CASSETTE
162 163
COM
MERC
IAL
Wider
567mm
80mm
487mm
27°C
15°C
Air flow dead zonein 4 corners
950/700 Panel – Wide Jet Air FlowImproved vanes reduce the curved area and provide even distribution.
Convenient Panel InstallationThe detachable corner design makes it convenient to adjust the hanger during installation and to check for leakages in the drain connection pipe.
Conventional
27°C
15°C
Even air distribution
LG Cassette
* Wired remote controller PQRCVSL0 (QW) applied
Indirect Air FlowDirect Air Flow
Independent Vane OperationThe independent vane operation feature uses separate motors, making it possible to control all four vanes independently.
All Vane Operation Independent Vane Control
Attachable/detachable corner design
RefrigantPiping check
Hanger adjust
Drain leakage check
Hanger adjust
Drain Leakage Check Hanger Adjust
Drain leakage check
Hanger adjust
RefrigantPiping check
Hanger adjust
DetachableCorner Design
Attachable/detachable corner design
RefrigantPiping check
Hanger adjust
Drain leakage check
Hanger adjust
Drain Leakage Check Hanger Adjust
Drain leakage check
Hanger adjust
RefrigantPiping check
Hanger adjust
DetachableCorner Design
Drain leakage check and hanger adjust
Hanger adjust
Refrigerantpiping check and Hanger
adjust
Hanger adjust
* Operating with wired remote controller PREMTB100, PREMTB001 and wireless remote controller included in PTEGM0.
* Except CT09 NR2 / CT12 NR2 / CT18 NQ2* Applied to cassette panel PT-UMC1
4-Point Support Structure Auto Leveling
Auto Stop DetectionMemory for User’s Level
Memory
STOP Max.4.5m
Detachable Corner Design Hanger AdjustDrain Leakage Check
It is easy to attach the panel to the body, using the button type panel design
Auto Elevation GrilleEasy filter cleaning by using the elevation grill.
SINGLE SPLIT KEY FEATURES
CEILING MOUNTED CASSETTEKEY FEATURES
Model: PT-UMC1
4 5LG Cassette Air Conditioners
-
Quiet Operation with 3D Fan3D fan is applied to H-Inverter cassettes 10 ~ 14kW. It increases air flow but reduces noise.
* Standard Inverter 10kW
4dB (A)
New ModelPrevious Model
43dB (A)
47dB(A)
Prevent Ceiling PollutionCoanda design of air outlet can help prevent contamination of ceiling.
Previous Model Coanda Design
164 165
COM
MERC
IALQuiet Operation with 3D Fan
New technology of 3D fan is applied to H-Inverter cassettes 10 ~ 14kW. It increases air flow but reduces noise.
Blade Angle Changed : Increase air flow and decrease noise
Curved Leading Edge : Improve air flow in same RPM of conventional fans
Conventional
New
* Standard Inverter 10kW
4dB (A)
NewConventional
43dB (A)
47dB(A)
CeilingCeiling
CeilingPollutions
ProductLouver
ProductLouver
CeilingCeiling
CeilingPollutions
ProductLouver
ProductLouver
Prevent Ceiling PollutionCoanda design of air outlet can prevent contamination of ceiling.
Conventional Coanda Design
Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Definition of Power Input Nominal conditions – Performance tested under EN14511 3. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB / 19°C WB - Outdoor Temperature 35°C DB / 24°C WB Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB 4. Annual energy consumption : based on average use of 350 running hours in cooling and 1,400 hours in heating per year at seasonal condition 5. This product contains fluorinated greenhouse gases (R32)
INDOOR CT09R NR0 CT12R NR0 CT18R NQ0 CT24R NP0
Capacity Cooling Min / Nom / Max kW 1.0 / 2.5 / 2.8 1.4 / 3.4 / 3.9 2.0 / 5.0 / 5.7 2.84 / 6.8 / 7.8Heating Min / Nom / Max kW 1.2 / 3.2 / 3.4 1.6 / 4.0 / 4.6 2.2 / 5.8 / 6.8 3.2 / 8.0 / 8.8
Low Temperature Capacity Heating -7°C Max kW 2.7 3.6 4.9 7.2
Power Input (Set)Cooling Nom kW 0.63 0.97 1.56 1.94 Heating Nom kW 0.75 1.12 1.66 2.00
Power Input (Indoor) Min / Nom / Max W 10 / 20 / 20 10 / 20 / 20 10 / 30 / 40 20 / 50 / 60Running Current Cooling / Heating Nom A 2.7 / 3.5 4.3 / 5.0 7.1 / 7.5 8.6 / 8.8Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50EER 4.00 3.51 3.21 3.51COP 4.00 3.58 3.49 4.00SEER 6.77 6.58 6.25 7.70SCOP 4.36 4.40 4.25 4.60Pdesign (@-10°C) kW 3.0 3.0 4.1 5.8 Seasonal Energy Label Cooling / Heating A++ / A+ A++ / A+ A++ / A+ A++ / A+Annual Energy Consumption Cooling / Heating kWh 129 / 963 181 / 955 280 / 1,351 309 / 1,765
Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 9.52 (3/8)Gas mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2) Ø 15.88 (5/8)Drain O.D. / I.D. mm 32 / 25 32 / 25 32 / 25 32 / 25
Air Flow Rate High / Medium / Low m3/min 8.5 / 7.0 / 6.0 9.5 / 8.0 / 7.0 13.0 / 12.0 / 11.0 17.0 / 15.0 / 13.0Sound Pressure Cooling High / Medium / Low dBA 36 / 33 / 30 38 / 35 / 32 41 / 39 / 36 38 / 36 / 34Sound Power Cooling Max dBA 52 52 57 57Dehumidification Rate l/h 0.9 1.4 2.0 2.7Dimensions Body W x H x D mm 570 x 214 x 570 570 x 214 x 570 570 x 256 x 570 840 x 204 x 840Net Weight Body kg 14.0 14.0 14.3 20.5
Decoration Panel
Model PT-QCHW0 PT-QCHW0 PT-QCHW0 PT-MCHW0Color Morning Fog Morning Fog Morning Fog Morning FogDimensions W x H x D mm 620 x 20 x 620 620 x 20 x 620 620 x 20 x 620 950 x 25 x 950Weight kg 3.0 3.0 3.0 6.3
OUTDOOR UU09WR UL0 UU12WR UL0 UU18WR U20 UU24WR U40Compressor Type Twin Rotary Twin Rotary Twin Rotary Twin RotaryAirflow Rate Nom m3/min 32 32 50 58
Sound PressureCooling Nom dBA 47 49 47 48Heating Nom dBA 50 52 52 52
Sound Power Cooling Max dBA 65 65 63 67Dimensions W x H x D mm 770 x 545 x 288 770 x 545 x 288 870 x 650 x 330 950 x 834 x 330Net Weight kg 33.8 33.8 44.8 56.1
Refrigerant
Type R32 R32 R32 R32Charge g 900 900 1,100 1,600Additional Charge (after 7.5m) g/m 20 20 20 35GWP 675 675 675 675t-CO2 eq 0.61 0.61 0.74 1.08
Operation Range (Outdoor)Cooling Min ~ Max °C DB -15 ~ 48 -15 ~ 48 -15 ~ 48 -15 ~ 48Heating Min ~ Max °C WB -18 ~ 18 -18 ~ 18 -18 ~ 18 -18 ~ 18
Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50Power Supply Cable No. x mm2 3C x 2.5 3C x 2.5 3C x 2.5 3C x 2.5Transmission Cable No. x mm2 4C x 0.75 4C x 0.75 4C x 0.75 4C x 0.75Circuit Breaker A 15 15 20 25Piping Length Total Min ~ Max m 5~20 5~20 5 ~ 30 5 ~ 50Piping Elevation Difference IDU - ODU Max m 15 15 30 30
Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 9.52 (3/8)Gas mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2) Ø 15.88 (5/8)
CT09RCT12RCT18RCT24R
UU24WRUU09WRUU12WR
UU18WR
STANDARD INVERTER (R32)
LG participates in the ECP programme for EUROVENT AC program.Check ongoing validity of certification : www.eurovent-certification.com
SINGLE SPLIT KEY FEATURES
CEILING MOUNTED CASSETTESINGLE SPLIT SPECIFICATION
CEILING MOUNTED CASSETTE
164 165
COM
MERC
IALQuiet Operation with 3D Fan
New technology of 3D fan is applied to H-Inverter cassettes 10 ~ 14kW. It increases air flow but reduces noise.
Blade Angle Changed : Increase air flow and decrease noise
Curved Leading Edge : Improve air flow in same RPM of conventional fans
Conventional
New
* Standard Inverter 10kW
4dB (A)
NewConventional
43dB (A)
47dB(A)
CeilingCeiling
CeilingPollutions
ProductLouver
ProductLouver
CeilingCeiling
CeilingPollutions
ProductLouver
ProductLouver
Prevent Ceiling PollutionCoanda design of air outlet can prevent contamination of ceiling.
Conventional Coanda Design
Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Definition of Power Input Nominal conditions – Performance tested under EN14511 3. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB / 19°C WB - Outdoor Temperature 35°C DB / 24°C WB Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB 4. Annual energy consumption : based on average use of 350 running hours in cooling and 1,400 hours in heating per year at seasonal condition 5. This product contains fluorinated greenhouse gases (R32)
INDOOR CT09R NR0 CT12R NR0 CT18R NQ0 CT24R NP0
Capacity Cooling Min / Nom / Max kW 1.0 / 2.5 / 2.8 1.4 / 3.4 / 3.9 2.0 / 5.0 / 5.7 2.84 / 6.8 / 7.8Heating Min / Nom / Max kW 1.2 / 3.2 / 3.4 1.6 / 4.0 / 4.6 2.2 / 5.8 / 6.8 3.2 / 8.0 / 8.8
Low Temperature Capacity Heating -7°C Max kW 2.7 3.6 4.9 7.2
Power Input (Set)Cooling Nom kW 0.63 0.97 1.56 1.94 Heating Nom kW 0.75 1.12 1.66 2.00
Power Input (Indoor) Min / Nom / Max W 10 / 20 / 20 10 / 20 / 20 10 / 30 / 40 20 / 50 / 60Running Current Cooling / Heating Nom A 2.7 / 3.5 4.3 / 5.0 7.1 / 7.5 8.6 / 8.8Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50EER 4.00 3.51 3.21 3.51COP 4.00 3.58 3.49 4.00SEER 6.77 6.58 6.25 7.70SCOP 4.36 4.40 4.25 4.60Pdesign (@-10°C) kW 3.0 3.0 4.1 5.8 Seasonal Energy Label Cooling / Heating A++ / A+ A++ / A+ A++ / A+ A++ / A+Annual Energy Consumption Cooling / Heating kWh 129 / 963 181 / 955 280 / 1,351 309 / 1,765
Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 9.52 (3/8)Gas mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2) Ø 15.88 (5/8)Drain O.D. / I.D. mm 32 / 25 32 / 25 32 / 25 32 / 25
Air Flow Rate High / Medium / Low m3/min 8.5 / 7.0 / 6.0 9.5 / 8.0 / 7.0 13.0 / 12.0 / 11.0 17.0 / 15.0 / 13.0Sound Pressure Cooling High / Medium / Low dBA 36 / 33 / 30 38 / 35 / 32 41 / 39 / 36 38 / 36 / 34Sound Power Cooling Max dBA 52 52 57 57Dehumidification Rate l/h 0.9 1.4 2.0 2.7Dimensions Body W x H x D mm 570 x 214 x 570 570 x 214 x 570 570 x 256 x 570 840 x 204 x 840Net Weight Body kg 14.0 14.0 14.3 20.5
Decoration Panel
Model PT-QCHW0 PT-QCHW0 PT-QCHW0 PT-MCHW0Color Morning Fog Morning Fog Morning Fog Morning FogDimensions W x H x D mm 620 x 20 x 620 620 x 20 x 620 620 x 20 x 620 950 x 25 x 950Weight kg 3.0 3.0 3.0 6.3
OUTDOOR UU09WR UL0 UU12WR UL0 UU18WR U20 UU24WR U40Compressor Type Twin Rotary Twin Rotary Twin Rotary Twin RotaryAirflow Rate Nom m3/min 32 32 50 58
Sound PressureCooling Nom dBA 47 49 47 48Heating Nom dBA 50 52 52 52
Sound Power Cooling Max dBA 65 65 63 67Dimensions W x H x D mm 770 x 545 x 288 770 x 545 x 288 870 x 650 x 330 950 x 834 x 330Net Weight kg 33.8 33.8 44.8 56.1
Refrigerant
Type R32 R32 R32 R32Charge g 900 900 1,100 1,600Additional Charge (after 7.5m) g/m 20 20 20 35GWP 675 675 675 675t-CO2 eq 0.61 0.61 0.74 1.08
Operation Range (Outdoor)Cooling Min ~ Max °C DB -15 ~ 48 -15 ~ 48 -15 ~ 48 -15 ~ 48Heating Min ~ Max °C WB -18 ~ 18 -18 ~ 18 -18 ~ 18 -18 ~ 18
Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50Power Supply Cable No. x mm2 3C x 2.5 3C x 2.5 3C x 2.5 3C x 2.5Transmission Cable No. x mm2 4C x 0.75 4C x 0.75 4C x 0.75 4C x 0.75Circuit Breaker A 15 15 20 25Piping Length Total Min ~ Max m 5~20 5~20 5 ~ 30 5 ~ 50Piping Elevation Difference IDU - ODU Max m 15 15 30 30
Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 9.52 (3/8)Gas mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2) Ø 15.88 (5/8)
CT09RCT12RCT18RCT24R
UU24WRUU09WRUU12WR
UU18WR
STANDARD INVERTER (R32)
LG participates in the ECP programme for EUROVENT AC program.Check ongoing validity of certification : www.eurovent-certification.com
SINGLE SPLIT KEY FEATURES
CEILING MOUNTED CASSETTESINGLE SPLIT SPECIFICATION
CEILING MOUNTED CASSETTE
164 165
COM
MERC
IALQuiet Operation with 3D Fan
New technology of 3D fan is applied to H-Inverter cassettes 10 ~ 14kW. It increases air flow but reduces noise.
Blade Angle Changed : Increase air flow and decrease noise
Curved Leading Edge : Improve air flow in same RPM of conventional fans
Conventional
New
* Standard Inverter 10kW
4dB (A)
NewConventional
43dB (A)
47dB(A)
CeilingCeiling
CeilingPollutions
ProductLouver
ProductLouver
CeilingCeiling
CeilingPollutions
ProductLouver
ProductLouver
Prevent Ceiling PollutionCoanda design of air outlet can prevent contamination of ceiling.
Conventional Coanda Design
Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Definition of Power Input Nominal conditions – Performance tested under EN14511 3. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB / 19°C WB - Outdoor Temperature 35°C DB / 24°C WB Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB 4. Annual energy consumption : based on average use of 350 running hours in cooling and 1,400 hours in heating per year at seasonal condition 5. This product contains fluorinated greenhouse gases (R32)
INDOOR CT09R NR0 CT12R NR0 CT18R NQ0 CT24R NP0
Capacity Cooling Min / Nom / Max kW 1.0 / 2.5 / 2.8 1.4 / 3.4 / 3.9 2.0 / 5.0 / 5.7 2.84 / 6.8 / 7.8Heating Min / Nom / Max kW 1.2 / 3.2 / 3.4 1.6 / 4.0 / 4.6 2.2 / 5.8 / 6.8 3.2 / 8.0 / 8.8
Low Temperature Capacity Heating -7°C Max kW 2.7 3.6 4.9 7.2
Power Input (Set)Cooling Nom kW 0.63 0.97 1.56 1.94 Heating Nom kW 0.75 1.12 1.66 2.00
Power Input (Indoor) Min / Nom / Max W 10 / 20 / 20 10 / 20 / 20 10 / 30 / 40 20 / 50 / 60Running Current Cooling / Heating Nom A 2.7 / 3.5 4.3 / 5.0 7.1 / 7.5 8.6 / 8.8Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50EER 4.00 3.51 3.21 3.51COP 4.00 3.58 3.49 4.00SEER 6.77 6.58 6.25 7.70SCOP 4.36 4.40 4.25 4.60Pdesign (@-10°C) kW 3.0 3.0 4.1 5.8 Seasonal Energy Label Cooling / Heating A++ / A+ A++ / A+ A++ / A+ A++ / A+Annual Energy Consumption Cooling / Heating kWh 129 / 963 181 / 955 280 / 1,351 309 / 1,765
Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 9.52 (3/8)Gas mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2) Ø 15.88 (5/8)Drain O.D. / I.D. mm 32 / 25 32 / 25 32 / 25 32 / 25
Air Flow Rate High / Medium / Low m3/min 8.5 / 7.0 / 6.0 9.5 / 8.0 / 7.0 13.0 / 12.0 / 11.0 17.0 / 15.0 / 13.0Sound Pressure Cooling High / Medium / Low dBA 36 / 33 / 30 38 / 35 / 32 41 / 39 / 36 38 / 36 / 34Sound Power Cooling Max dBA 52 52 57 57Dehumidification Rate l/h 0.9 1.4 2.0 2.7Dimensions Body W x H x D mm 570 x 214 x 570 570 x 214 x 570 570 x 256 x 570 840 x 204 x 840Net Weight Body kg 14.0 14.0 14.3 20.5
Decoration Panel
Model PT-QCHW0 PT-QCHW0 PT-QCHW0 PT-MCHW0Color Morning Fog Morning Fog Morning Fog Morning FogDimensions W x H x D mm 620 x 20 x 620 620 x 20 x 620 620 x 20 x 620 950 x 25 x 950Weight kg 3.0 3.0 3.0 6.3
OUTDOOR UU09WR UL0 UU12WR UL0 UU18WR U20 UU24WR U40Compressor Type Twin Rotary Twin Rotary Twin Rotary Twin RotaryAirflow Rate Nom m3/min 32 32 50 58
Sound PressureCooling Nom dBA 47 49 47 48Heating Nom dBA 50 52 52 52
Sound Power Cooling Max dBA 65 65 63 67Dimensions W x H x D mm 770 x 545 x 288 770 x 545 x 288 870 x 650 x 330 950 x 834 x 330Net Weight kg 33.8 33.8 44.8 56.1
Refrigerant
Type R32 R32 R32 R32Charge g 900 900 1,100 1,600Additional Charge (after 7.5m) g/m 20 20 20 35GWP 675 675 675 675t-CO2 eq 0.61 0.61 0.74 1.08
Operation Range (Outdoor)Cooling Min ~ Max °C DB -15 ~ 48 -15 ~ 48 -15 ~ 48 -15 ~ 48Heating Min ~ Max °C WB -18 ~ 18 -18 ~ 18 -18 ~ 18 -18 ~ 18
Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50Power Supply Cable No. x mm2 3C x 2.5 3C x 2.5 3C x 2.5 3C x 2.5Transmission Cable No. x mm2 4C x 0.75 4C x 0.75 4C x 0.75 4C x 0.75Circuit Breaker A 15 15 20 25Piping Length Total Min ~ Max m 5~20 5~20 5 ~ 30 5 ~ 50Piping Elevation Difference IDU - ODU Max m 15 15 30 30
Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 9.52 (3/8)Gas mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2) Ø 15.88 (5/8)
CT09RCT12RCT18RCT24R
UU24WRUU09WRUU12WR
UU18WR
STANDARD INVERTER (R32)
LG participates in the ECP programme for EUROVENT AC program.Check ongoing validity of certification : www.eurovent-certification.com
SINGLE SPLIT KEY FEATURES
CEILING MOUNTED CASSETTESINGLE SPLIT SPECIFICATION
CEILING MOUNTED CASSETTE
Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Definition of Power Input Nominal conditions – Performance tested under EN14511. 3. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB / 19°C WB - Outdoor Temperature 35°C DB / 24°C WB. Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB. 4. Annual energy consumption : based on average use of 350 running hours in cooling and 1,400 hours in heating per year at seasonal condition. 5. This product contains fluorinated greenhouse gases (R32). 6. Optional Fascia PT-UMC1.
SPECIFICATIONS
Indoor UnitUnit
UTN24R UTN36R UTN48R
Outdoor Unit UU24WR UU36WR UU48WR
Rated CapacityCooling kW 6.80 9.50 13.40
Heating kW 7.50 10.80 15.50
Capacity RangeCooling Min ~ Max kW 2.84 ~ 7.8 4.5 ~ 13.0 5.5 ~ 16.0
Heating Min ~ Max kW 3.2 ~ 8.3 5.0 ~ 13.7 6.1 ~ 18.0
Rated Power InputCooling kW 1.95 2.47 4.27
Heating kW 1.88 2.80 4.80
AEER / ACOP Cooling / Heating - 3.461 / 3.969 3.769 / 3.788 3.113 / 3.207
EER / COP Cooling / Heating - 3.487 / 4.000 3.846 / 3.857 3.138 / 3.229
Rated Current Cooling / Heating A 8.60 / 8.80 10.7 / 12.2 18.9 / 21.0
Max. Current (Full Load Amps)Indoor Unit A 0.6 1.0 1.0
Set A 17 28 28
Air Flow Rate L/s 283 / 250 / 216 500 / 416 / 333 550 / 466 / 366
External Static Pressure Pa - - -
Indoor
Sound Level at 1.5m H / M / L Pressure dB(A) 38 / 36 / 34 46 / 43 / 40 47 / 44 / 41
Dimensions W x H x D mm 840 x 204 x 840 840 x 288 x 840 840 x 288 x 840
Weight kg 20.5 24.6 24.6
Outdoor
Sound Level at 1.5m Cooling / Heating Pressure dB(A) 48 / 52 52 / 54 52 / 54
Sound Power Level dB(A) 67 66 68
Dimensions W x H x D mm 950 x 834 x 330 950 x 1,380 x 330 950 x 1,380 x 330
Weight kg 56.1 87.5 87.5
Power Supply V / Phase / Hz 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50
Circuir Breaker A 25 40 40
Compressor Type - Twin Rotary LG Inverter Scroll LG Inverter Scroll
RefrigerantType - R32 R32 R32
Precharged Length m 7.5 7.5 7.5
Pipe Sizes
Liquid mm/inch ∅ ∅ 9.52 (3/8) ∅ ∅ 9.52 (3/8) ∅ ∅ 9.52 (3/8)
Gas mm/inch ∅ ∅ 15.88 (5/8) ∅ ∅ 15.88 (5/8) ∅ ∅ 15.88 (5/8)
Drain OD / ID mm ∅ ∅ 32 / 25 ∅ ∅ 32 / 25 ∅ ∅ 32 / 25
Max. Pipe Length m 50 85 85
Max. Height Difference ODU ~ IDU m 30 30 30
Supply Air Opening H x W, Flange mm - - -
Return Air Opening H x W, Flange mm - - -
Continuous Operating RangeCooling °C DB - 15 ~ 48 - 15 ~ 48 - 15 ~ 48
Heating °C WB - 18 ~ 18 - 18 ~ 18 - 18 ~ 18
Demand Response - X X X
UTN24R / UU24WRUTN36R / UU36WRUTN48R / UU48WR
KEY FEATURES
Model: UTN36WH2 Model: UTN36R
Model: UTN36WH2
6 7LG Cassette Air Conditioners
-
8 9LG Cassette Air Conditioners
CONTROLLERS & ACCESSORIES
STANDARD CONTROLLER
DELUXE CONTROLLERThe Deluxe Remote Controller is 4.3” with colour design and touch button. The easy to use touch button with backlit LCD displays temperature, humidity, allows you to control the temperature setting and can control up to 8 zones.
• Set up to 8 zones• 4.3 inch colour display• Humidity sensor embedded• Touch button• Time display• Room temperature display• Room humidity display• Operation - On/Off• Mode - Auto/Cool/Dry/Heat/Fan• Occupied cooling and heating
temperature setpoints
The Premium Remote Controller is designed to suit even the most stylish interiors. The easy to use touchscreen panel with backlit LCD allows you to control the temperature with simplicity, and allows you to control up to 8 zones.
• Set up to 8 zones• 5 inch colour display• Touch screen• Time display• Room temperature display • Operation - On/Off • Mode - Auto/Cool/Dry/Heat/Fan • Occupied cooling and heating
temperature setpoints
• Unoccupied cooling and heating temperature setpoints
• Fan speed – Low/Med/High/Auto • Self diagnosis function• Auto restart on power failure• Sleep mode• Child lock• Energy monitor• Filter clean information• Weekly, yearly and holiday timer
PREMIUM CONTROLLER
• Unoccupied cooling and heating temperature setpoints
• Fan speed - Low/Med/High/Auto• Time limit function• Auto restart on power failure• Sleep mode• Child lock• Energy monitor• Filter clean information• Dail, weekly, yearly and holiday timer
The standard controller is compact and easy to use.
• 4.3 inch mono display• Time display• Room temperature display • Operation - On/Off • Fan speed – Low/Med/High/Auto• Self diagnosis function
• Auto restart on power failure• Sleep mode• Child lock• Filter clean information• Weekly timer
-
10 11LG Cassette Air Conditioners
ACCESSORIES
Control Method Objective/Use Unit Name and Model Function Parts Features
PI485
PMNFP14A1
To connect Outdoor unit to CNU or SimpleCentral Controller
• RS485 Converter with software• For Max.16 Indoor
• PCB Assembly• Bracket• Lead wire: 3ea• Screw 4EA• Tie wrap• Clamp• Manual
• 1set/1 Outdoor
Dry Contact
PDRYCB100
For connect Indoor unit to other Forced on/off Controller
• RS485 Converter with software
• PCB Assembly• Top case• Bottom case• Screw• Lead wire 3• Sub PCB set (1 leadwire + 1 sub PCB)• Manual
• 1set/1 Indoor unit
Dry Contact
PDRYCB400
For connect Indoor unit to other Forced on/off Controller
• Contact signal to air-con signal converter
• PCB Assembly• Top/Bottom case• Screw• Lead wire 3ea• Sub PCB set (1 leadwire + 1 sub PCB)• Manual
• 1set/1 indoor unit• 2 Contact points• No need AC input• Expected temperature setting is possible
*Dred/Dry contact.
INTERFACE DEVICE
OPTIONAL ACCESSORIES*Model Description
PREMTB001 Standard Wired Wall Controller
PREMTB100 Deluxe Wired Wall Controller
PREMTA000 Premium Controller
PWLSSB21H Wireless Remote Control
PWFMDD200 WiFi Dongle + 1.1m Cable
PWYREW000 10m Cable
PT-UMC1 Cassette Fascia
PTEGMO Auto Ellevation Grille
*Refer to each model PDB for application accessories.
Control Method Objective/Use Unit Name and Model Function Parts Features
BNU-LW
PLNWKB000
To connect PI485 to LONWORKS BMS system
• Interface between BMS and LG air-conditioners (LonMark certified : Operation system based on LNS)
• Interface Assembly
• 12V DC adaptor• Manual
• 64 indoor units• ACP function (central controller) included
BNU-BAC
PQNFB17C 0
To connect PI485 to BACnet BMS system
• Interface between BMS and LG air-conditioners (BTL certified : Operation system based on BACnet service)
• Interface Assembly• 12V DC adaptor• Manual
• 256 Indoor units• ACP function (central controller) included• BTL certification (B-ASC)
PDI STANDARD
PPWRDB000
To Power consumption Distribution of each indoor unit2-port
• Accumulation of total power consumption• Indication of current power in use• Indication of accumulated power for period• Indication of standby power (option setting)
• PDI Assembly Manual
• 1 PDI / 2 Outdoor
PDI Premium
PQNUD1S40
To power consumption distribution of each indoor unit8-port
• Accumulation of total power consumption • Indication of current power in use• Indication of accumulated power for period • Indication of standby power• Blackout protection
• PDI Assembly manual
• 1 PDI / 8 Outdoor
1) PI485 : Product Interface unit for RS 485 transmission
BUILDING MANAGEMENT DEVICES
ACCESSORIES
-
For more information visitlg.com/au/cassette February 2021