Valves, controls + systems
“Cofloor” surface heating and cooling systemsSystems with distributor/collector
Product range
Innovation + Quality
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 2/1082
Content
Content
Page
2 Content
3 Summary
4–5 Systems
6 Pipes
7 “Cofloor” base mat system forheating/cooling
8 Examples of installation
9 “Cofloor” tacker system and clamp-ing rail system for folded board orbase mat roll for heating/cooling
10 Examples of installation
11 “Cofloor” dry-build system for heat-ing/cooling – Accessories
12 Examples of installation
13 “Cofloor” dry-build system for heat-ing/cooling with laminate flooring aslayer for load distribution
14 “Cofloor” system for wall heatingand cooling – Wet-build system
15 Practical example wall heating andcooling – Wet-build system
16 “Cofloor” system for wall heatingand cooling – Dry-build system
17 Practical example wall heating andcooling – Dry-build system
18 “Cofloor” base mat system NP-R forheating/cooling
19 “Cofloor system industry for heatingand cooling
20 Floor construction/Standardconstructions – Base mat, tackerand clamping rail system
21 Floor construction – Standardconstructions – Dry-build system
22 Floor construction – Standardconstructions – Base mat NP-R andindustry systems
23 Performance table for rapid design– Base mat NP and tacker system –PE-Xc pipes “Copex”, PE-RTpipes “Copert” and “Copipe” pipes,14 x 2 mm
24 Performance table for rapid design– Base mat NP and tacker system– PE-Xc pipes “Copex”, PE-RTpipes “Copert” and “Copipe” pipes,14 x 2 mm, 17 x 2 mm
25 Performance table for rapid design– Dry-build system – “Copipe”pipes, 14 x 2 mm
26 Performance table for rapid design– Base mat NP-R system – PE-RTpipes “Copert”, 12 x 2 mm
26-27 Performance charts for differentfloor coverings – PE-Xc pipes“Copex”, PE-RT pipes “Copert” and“Copipe” pipes – Base mat NP andtacker system
28 Performance charts for differentfloor coverings – “Copipe” pipes –Dry-build system
29-30 Performance charts for differentfloor coverings – PE-RT pipes“Copert” – Base mat NP-R system
31 Stainless steel distributors/collectors“Multidis SF” for surface heating andcooling systems
32 Stainless steel distributor/collector“Multidis SFB” with presettable by-pass for surface heating and coolingsystems
33 Hydronic balancing of the heatingcircuits – Regulation with flow
measuring and regulating device 34 Hydronic balancing of the heatingcircuits – Regulation with regulatinginserts
35 Brass distributor/collector “MultidisSFI” for industrial surface heatingand cooling systems
36 Flow temperature control of surfaceheating systems – Control unit“Regufloor H” and boiler connec-tion system “Regumat F-130”
37 Weather guided flow temperaturecontrol of surface heating systems– Control unit “Regufloor HW”
38 Flow temperature control of surfaceheating systems – Control unit
“Regufloor HX” with system sepa-ration
39 “Cofloor” system extension forsurface cooling – Control unit“Regufloor HC” for alternate oper-ation of heating and cooling for alllaying systems
40 “Cofloor” system extension for sur-face cooling – Heating surfaceregulation for heating and cooling– Example of surface heating andcooling system
41 Heating circuit regulation of surfaceheating systems – Actuators androom thermostats – Wireless con-trols
42 Accessories for stainless steeldistributors/collectors – Doubleregulating and commissioningvalves for hydronic balancing –Heat meter connection set
43 Accessories for stainless steeldistributors/collectors – Differentialpressure regulators for hydronicbalancing – Heat meter connectionset
44 Dwelling station “Regudis W-HTF”–Integration of surface heating andcooling
45 “Unibox TSH” / “Unibox T” / UniboxE T” / “Unibox E TC” – Individualroom temperature control in surfaceheating systems
46 “Unibox RTL” / “Unibox E RTL”“Unibox plus” / “Unibox E plus”
47 “Unibox vario”, “Unibox E vario”
48 Application – Installation andassembly
49 Cabinets – Installation instruc-tions/Dimension chart
50 Surface-mounted cabinets - Instal-lation instructions/Dimension chart
51 Surface-mounted cabinets “Regu-floor HX” – Installation instruc-tions/Dimension chart
52-53 Sample form – “Cofloor” materiallist
54 Sample form – Pressure test record
of the Oventrop surface heatingand cooling system “Cofloor”according to EN 1264-4
55 Sample form – Heating up record ofthe “Cofloor” base mat, tacker andclamping rail system
56 Sample form – Heating up record ofthe “Cofloor” dry-build system
57 Sample form – Heating up record ofthe “Cofloor” base mat NP-Rsystem
58-107 Illustrated list – “Cofloor” surfaceheating and cooling systems –Extract from the catalogue 2013
108 Advantages, service
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 3/1083
Surface heating and cooling system“Cofloor”:practical and functional
With the surface heating/cooling system“Cofloor”, Oventrop offers the specialisttrade not only products of first class qual-ity but also all components required for theeconomical installation of various layingsystems.
This includes base mats, a tacker sys-tem (base mat rolls and folded boards), aclamping rail system, a dry-build system,edge isolating strips, stainless steel dis-tributors/collectors, components for regula-tion and hydronic balancing, cabinets,pipes etc., all complying with standards,coordinated and in accordance with the lat-est technical developments.
Regarding the heating pipes, the user maychose the PE-Xc pipe “Copex”, the compo-sition pipe “Copipe” or the PE-RT pipe“Copert”. All pipes can be laid fast and eas-ily by only one person.
The composition pipe “Copipe” is alsosuitable for supply pipes and for the con-nection to heating or cooling generatorsand distributors/collectors.
As is generally known, a surface heatingsystem only works perfectly if hydronicbalancing of the mass flow in the supplypipes and heating circuits was carried outcorrectly. A main factor for a trouble-freeoperation of surface heating and coolingsystems is to ensure that the central flowtemperature control in front of the distribu-tor/collector and also the automatic individ-ual room temperature control of each
Summary
circuit at the distributor/collector is func-tioning correctly. This can only be achievedthrough hydronic balancing, i.e. the distri-bution of mass flow according to the heatdemand of the whole system.Oventrop offers a wide-ranging completeprogramme of valves and controls, suitablefor any surface heating system.
Surface heating and cooling:comfortable and economical
The times when energy was wasted care-lessly are over. Nowadays the maxim is“Save energy”. Not only because of thecontinuously rising cost for oil and gas,but also to avoid environmental pollution.This is why the surface heating and to anincreasing extent the surface cooling arebecoming more and more important whenchoosing the heating/cooling system fornew buildings as well as for renovationprojects. Comfort temperatures cannotonly be achieved economically during
heating periods but also during periodsof alternate heating and cooling. Energysavings result from the fact that the heat ina surface heating system spreads evenlyand that the flow temperature of the heat-ing and cooling water does not differ thatmuch from the room temperature (duringheating periods approx. 35°C instead of70°C and during cooling periods not below16°C). Another advantage which, when combinedwith a modern heating and cooling genera-tor, e.g. a low temperature or gross calo-rific boiler, heat pumps or cooled waterfrom a well, reflects in the energy con-sumption. A further energy saving is madeas temperatures can be reduced from thenormal 22°C to 20°C without loosing the“comfort” feeling.Moreover, surface heating stirs up lessdust than radiator systems and dry floorsprevent the build-up of germs, mites andfungus which can cause allergies.
f o r b e
t t e r
e n e r g y e f f i c i e n c y.
..
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 4/1084
Systems
Base mat system NPFor laying (45° diagonal laying pattern with-out auxiliary material) of 14 or 16 mm Oven-trop PE-Xc pipes “Copex”, PE-RT pipes
“Copert” or composition pipes “Copipe”.Size 1.00 m x 1.00 m with thermal andsound insulation made of expanded poly-styrene, thermal conductivity group 040,types:- thickness 35 mm covered with a poly- styrene foil,- thickness 11 mm covered with a poly- styrene foil,- without thermal insulation,
building material class B 2 accordingto DIN 4102.
Simple and economical laying of pipescarried out by one person only due to thespecial geometric design of the nodules.Clean coverage of joints due to over-lapping polystyrene foil.
Tacker systemBase mat roll or folded board made of ex-panded polystyrene according to DIN EN16163,thermal conductivity group 045 or 040for 30-2 mm,building material class B 2 accordingto DIN 4102,with laminated tissue foil,with imprinted laying screen (screendistance 50 mm),foil overlap on the edge,with adhesive strip on the opposite.Fixing of the Oventrop PE-Xc pipes“Copex”, PE-RT pipes “Copert” or com-position pipes “Copipe” with plastic tackerhooks and tacker machine.
Easily laid and trimmed even in areas withdifficult access.
Dry-build systemDry-build element 1000 x 500 x 25 mmmade of expanded polystyrene accordingto DIN EN 16163,thermal conductivity group 035,building material class B 1 according toDIN 4102.For the simple installation on solid timberbeam floors and wood flooring with the dry-build system (e.g. when renovating olderbuildings) or with heating screed accordingto DIN 18560 on polyethylene foil.The heat/cooling conducting strips allowan either spiral or serpentine patterned lay-
ing of the composition pipe “Copipe” 14 x2 mm. (Oventrop recommends the use of“Copipe” pipes because of their minimalthermal expansion). The Oventrop dry-buildsystem is also suitable for a wall heating orcooling installation.
Clamping rail systemSelf-adhesive clamping rails made of poly-propylene, clamping distance 50 mm,length 1 m, for fixing 14 or 16 mm heatingpipes onto the insulation (base mats orfolded boards). Advantage: laminated tissue foil will not bedamaged by the clamping rail.The clamping rails are also suitable forthe construction of a wall heating or cool-ing installation together with the Oventrop
composition pipe “Copipe” laid in a serpen-tine pattern.
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 5/1085
Systems
Base mat system NP-RFor laying (45° diagonal laying pattern with-out auxiliary material) of 12 mm OventropPE-RT pipes “Copert”.
Size 1.00 x 1.00 m, made of moulded poly-styrene foil,with adhesive layer on reverse.The perforation of the base mats allows asimple application and a safe bonding ofthe levelling compound and the existingground.Tested minimum construction heights:- Knauf levelling compound Alphadur 430 min. 17 mm- PCI periplan min. 18 mm- Weber-Maxit weber.floor min. 18 mm- Knauf levelling screed 425 min. 21 mm
Industrial system
Components:- PE-Xc pipes “Copex” (20 x 2 mm and 26 x 3 mm)- Distributor/collector (of modular con- struction for a maximum of 20 heating
circuits and accessories)- Compression fittings (20 x 2 mm and 26 x 3 mm)For laying of industrial and commercialsurface heating systems, e.g. on reinforce-ment steel mesh.
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 6/1086
Pipes
1
4
2
3
5
1 Composition pipe “Copipe HSC” made ofPE-RT/AL/PE-RTSizes: 14 x 2.0 mm, 16 x 2.0 mm 20 x 2.5 mm, 26 x 3.0 mm
Max. pressure and temperature:6 bar at 90°C, 10 bar at 70°C
2 Composition pipe “Copipe HS” made ofPE-Xc/AL/PE-XcSizes: 14 x 2,0 mm, 16 x 2.0 mm 20 x 2.5 mm, 26 x 3.0 mmMax. pressure and temperature:10 bar at 95°C, 16 bar for cold water
3 PE-Xc plastic pipe “Copex” made ofcross-linked polyethylene (PE-X), with oxy-gen barrierSizes: 14 x 2.0 mm, 16 x 2.0 mm, 17 x 2.0 mm, 20 x 2.0 mm, 26 x 3.0 mmMax. pressure and temperature:6 bar at 90°C, 10 bar at 60°C (8 bar at 70°Cfor 20 x 2.0 mm)
4 PE-RT plastic pipe “Copert” made ofcross-linked polyethylene (PE-RT), withoxygen barrierSizes: 14 x 2.0 mm, 16 x 2.0 mm, 17 x 2.0 mm, 20 x 2.0 mmMax. pressure and temperature:6 bar at 70°C
5 Pressure loss chartfor PE-Xc pipes “Copex” , PE-RT pipes“Copert” and composition pipes “Copipe”sized 14 x 2.0 mm, 16 x 2.0 mm,17 x 2.0 mm and 20 x 2.0 mm.With flow velocity indication of the heatingwater.
Flow of heating water mFluid [kg/h]
R e s i s t a n c e R [ m b a r / m ]
Flow of heating water mFluid [kg/s]
R e s i s t a n c e R [ P a s c a l / m ]
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 7/1087
“Cofloor” base mat systemfor heating/cooling
1
1 The Oventrop base mat system “Cofloor”with its coordinated components allows afast laying of the pipes by only one person.
The Oventrop base mats NP-35 and NP-11are a suitable thermal and sound insulationmade of expanded polystyrene, thermalconductivity group 040, covered with apolystyrene foil, building material class B 2,which is laid directly onto concrete screedor, if required, onto the additional insulation.
The special grid pattern (50 mm betweenthe nodules) is suitable for 14 or 16 mm PE- Xc pipes “Copex”, PE-RT pipes “Copert”and composition pipes “Copipe”.
The handy base mats have practically nowastage. They can be laid economicallyand easily in any room whether it is smallwith many angles or with a large surfacearea.
Laying base mats in larger rooms starts ina corner opposite the entrance door. Theouter rows of the base mats are connectedlike a press button closure. At the end ofthe room the base mats can be cut to sizeas required. Any off cuts can be used in thesame order.
By using the polyethylene foil of the edgeisolating strip and the overlap of the basemat, the floor surface is completely coveredand ready for the concrete or liquid screedto be laid.
Therefore a sound bridge to the raw con-crete flooring is avoided.
Several types of base mats are availablewith varying thickness of insulation: NP-35,NP-11 and the foil base mat NP-R (withoutthermal insulation made of polystyrene).
2 The nodules of the polystyrene foil (NP-35and NP-11) are filled with polystyrene foam.This increases the firmness of the nodulesfor the pipe fixing and secures the heatingor cooling pipes firmly.
Improved sound insulation of the basemat with a thickness of 35-2 mm:28 dB
2
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 8/1088
Examples of installation
5
3 4
6 7
1 The handy base mats NP-35 (illustr.) andNP-11 are thermal and sound insulated.If required, additional insulation has to beconsidered, see notes on page 20.
2 The systematic laying begins by placingthe edge isolating strip along the walls.The edge isolating strip has an additionalbonded foil, allowing a sufficient sealing ofthe surface for use with concrete or liquidscreed.
3 The tight fitting of the base mats at theedges is ensured through a continuedgrooved edging. Like a press button clos-ure, the overlap is pressed onto the firstrow of nodules of the adjoining mat andthus closes the area off completely (mostimportant when using liquid screed).
4 The strong structure of the nodules andthe clear grid pattern of 50 mm allow aclean and simple fitting of the pipes by only
one person with the calculated distance ofthe pipes being maintained.
5 The coil unwinder allows and easy andclean laying of the pipes on the mats.
6 In doorways and passages, an expansionstrip separates individual floor areas fromeach other. A slit corrugated pipe sleeveprotects the pipes where they cross over.
7 Having submitted the surface heatingpipes to a pressure test, concrete can belaid.
1 2
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 9/1089
“Cofloor” tacker system and clamping rail systemfor folded board or base mat roll
for heating/cooling
2
4
3
1
1 The economical Oventrop “Cofloor”tacker and clamping rail systems for foldedboard and base mat roll consist of a foldedboard 2 x 1 m or a base mat roll 10 x 1 m
for use with concrete or anhydrite liquidscreed. The folded board and base mat rollare made of expanded polystyrene and arelaminated with a tissue foil with an imprin-ted laying screen (screen distance 50 mm).
One longitudinal edge of the folded boardand of the base mat roll has a foil overlapand the opposite edge is equipped with anadhesive tape preventing the penetrationof humidity into the underlying insulationwhen applying concrete or anhydrite liquidscreed.
The folded board and base mat roll areclassed in the thermal conductivity group045 and 040 for 30-2 mm, building mate-rial class B 2 according to DIN 4102 with amaximum load of 4 kN/m² and 5 kN/m² for30-2 mm.
The 14, 16 or 17 mm Oventrop PE-Xcplastic pipes “Copex”, PE-RT plastic pipes“Copert” as well as the composition pipes“Copipe” are fixed onto the folded boardor base mat roll with tacker hooks or self-adhesive clamping rails made of polypropy-lene.
The folded boards and base mat rolls arelaid directly onto the concrete screed or, ifrequired, onto the additional insulation.
The Oventrop folded boards or base matrolls are laid in the same manner as thebase mats, starting in a corner of the roomopposite the entrance door. Off cuts can beused in the same order which leaves mini-mum wastage.
The “Cofloor” folded boards, base matrolls, tacker hocks or clamping rails allowan economical, quick and simple laying ofall components.
The imprinted laying screen makes it easyto lay the pipes either in a spiral or serpen-tine pattern.
The tissue foil ensures a secure fixing of thetacker hooks and/or the clean fitting of theself-adhesive clamping rails.
2,3 Due to the imprinted 50 mm layingscreen on the foil, Oventrop folded boardsor base mat rolls reflect a clean and orderlypicture of the pipework with 14, 16 or 17
mm PE-Xc pipes “Copex”, PE-RT pipes“Copert” or composition pipes “Copipe”.The clear lines of the laying screen make itvery easy to tack the pipes in a straight linewith the handy Oventrop tacker machine.
4 Self-adhesive clamping rails made ofpolypropylene, clamping distance 50mm, for 14 or 16 mm PE-Xc plastic pipes“Copex”, PE-RT plastic pipes “Copert” orcomposition pipes “Copipe” .
Length of rail 1 m; for fixing the pipe ontothe insulation.Improved sound insulation of the basemat roll with a thickness of20-2 mm, 26 dB35-2 mm, 29 dB30-3 mm, 29 dB25-2 mm, 28 dB30-2 mm, 28 dB
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 10/10810
Examples of installation
3 4
6
75
1 Laying of the “Cofloor” system “foldedboard” starts at the edge isolating stripat the right hand side wall in the relevantroom. The 100 x 200 cm folded board with
the reinforced tissue foil allows a fast lay-ing of the base. If required, an additionalinsulation should be considered (see page20 for further details).
2 If liquid screed is to be used, then theedge isolating strip must be additionallysealed (e.g. using a tape gun with self-adhesive tape).
3 One longitudinal edge of the folded boardand of the base mat roll has a foil overlapand the opposite edge is equipped withan adhesive tape which is covered with aplastic strip.
4 Laying the base mat roll (10 x 1 m). Ma-terial and process are identical to thoseused for the folded boards.
5 By using the Oventrop tacker machine,laying can be carried out economicallyby one single person. The 50 mm layingscreen imprinted on the foil, helps to fit thepipes in clear and straight lines. The sta-bility and strength of the tacker hooks andtissue foil ensure that the pipes are fixedsecurely.
6,7 The “Cofloor” clamping rail system(length = 1 m) with a self-adhesive strip for14 and 16 mm pipes, allows a clean andfast pipe fixing without damaging the tissuefoil. This also means that it is an additionaladvantage when using liquid screed.
1 2
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 11/10811
“Cofloor” dry-build system for heating/cooling Accessories
2
4
3
1
1 Apart from the base mat system and thetacker system where wet concrete is used,Oventrop offers the “Cofloor” dry-build sys-tem. The components of the dry-build sys-
tem are suitable for renovating old buildingsas well as for new buildings. The Oventropdry-build surface heating/cooling systemcan be combined with standard dry flooringelements (such as Fermacell boards) butalso with normal concrete or liquid screed.
The “Cofloor” dry-build basic element con-sists of 25 mm thick polystyrene foam.It serves as thermal insulation and at thesame time as carrier for the individual dry-build heat/cooling conducting strips. Thespecific order of the grooves of the basicelement allows the Oventrop 14 x 2 mmcomposition pipe “Copipe” to be laid eitherin a spiral or serpentine pattern.Other patterns are also possible.
Oventrop recommends using the compo-sition pipe “Copipe” as it has a lower ex-pansion coefficient than the PE-Xc/PE-RTplastic pipes. A quiet operation within theheat/cooling conducting strips is thereforecertain.
The strips made of galvanised sheet steelwith a thickness of 0.4-0.5 mm are the opti-mum heat/cooling conductor into the dryflooring elements or the concrete or liquidscreed.
The practical pre-punched breaks points ofthe strips (998 mm long) allow an optimumplacement in any room.
Advantages:- the installation of the Oventrop dry-build
system “Cofloor” is without wastage andcan be carried out by only one person
- overall height is reduced compared to wetscreeds
- optimum heating/cooling output via thegalvanised steel sheet strips and elbows
- no delay in the building progress whendry flooring elements are installed
- no warm up period is to be observed withdry flooring elements
- the floor can be walked on immediatelyafter installation
The Oventrop dry-build system “Cofloor”can be used for wall heating/cooling evenwhen pipes are installed in a serpentinepattern.
2 Dry-build element made of expanded
polystyrene (1000 x 500 x 25 mm) with agrooved pattern for fully fitting any room.
3 Heat/cooling conducting strips installedas 90° elbow for spiral patterned laying.
4 Installed heat/cooling conducting elbowwhere the pipe loops in a serpentine pat-terned layout.
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 12/10812
Examples of installation
5 6
3 4
7
1 2
1 Installation of the heat/cooling conduct-ing strips (998 x 122 x 0.4 mm) with pre-punched break points in the grooves of thedry-build element.
2 Installation of the heat/cooling conductingelbows (110 x 245 x 0.5 mm) with squeezefit design, allowing the pipes to be held inthe elbow without tension.
3,4 Simple laying of the Oventrop compo-sition pipe “Copipe” by just one person intothe preformed channel of the heat/coolingconducting strips and elbows.
5 Edge isolating strip and pipe conduit forfeeding pipe through the wall for dry-buildsystem.
6 Cutting individual pipe channels into theinfill channel, using the hot cutting machine.
7 Covering the installed pipes in the dry-build element with 0.2 mm polyethylene foil
for separation purposes.Quick calculation/ Determination of required material:
Required material for spiral patternedlayout of composition pipe “Copipe”14 x 2 mm:
per m² dry-build element:
7.70 m heat/cooling conducting steelsheets*)
Composition pipe “Copipe”*)⩠
4.00 m for laying distance 250 mm⩠ 8.00 m for laying distance 125 mm
Required material for serpentine patternedlayout of composition pipe “Copipe”
14 x 2 mm:per m² dry-build element:
approx. 8.00 m heat/cooling conductingsteel sheets*)
deduct
number/surface of heat/cooling conductingsteel sheets where pipe loops (size of theheat/cooling conducting elbows110 x 245 x 0.5 mm)
Composition pipe “Copipe”*)⩠
4.00 m for laying distance 250 mm⩠ 8.00 m for laying distance 125 mm
Please note:*) These figures are only a guide and do
not replace the exact layout and calcula- tion with the Oventrop software “OVplan”
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 13/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 14/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 15/10815
Practical example wall heating and coolingWet-build system
2
4
3
1 Snap clamping rails together to the re-quired length. Tear off foil. Bond clampingrails onto insulation board or wall and fixonto the brickwork/base with suitable wall
fixings (dowel).(Max. laying distance between clampingrails: 80 cm – vertical)
2 Feed composition pipe “Copipe” from thesupply of the distributor to the wall heat-ing/cooling. Now, starting from the bottom,press the pipe into the clamping rails in ahorizontal serpentine pattern. (Laying dis-tance depending on the model is 10 – 20cm.)
3 A space of 5 cm should be left at theedges for plastering (from the pipe edgeto the end of the wall heating surface). Theinstallation of a venting facility is recom-mended.
4 Lower edge connection of the wall heat-
ing system to the continuing pipework.
1
Venting
SupplyReturn
Screed
Bare floor
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 16/10816
“Cofloor” system for wall heating and coolingDry-build system
2
1
The large wall surfaces of a room are idealfor the installation of a heating or cool-ing system with composition pipes (e.g.“Copipe”).
Wall heating or cooling systems are lowtemperature systems. The temperatureof the heating medium or coolant is onlyslightly above or below the room tempera-ture and most of the energy is radiated.
With the Oventrop “Cofloor” dry-build wallheating and cooling system, the pipes withthe conducting strips and elbows are inte-grated in the thermal insulation. Due tothe large-surface covering of the dry-buildelements, the conducting strips allow atransmission of the heat into the room viathe wall finish.
The dry-build elements serve as insulationand carrier for the conducting strips andelbows. The pre-punched break points of
the strips allow an optimum covering of thewall surfaces.
Provided that no additional insulation isrequired, the dry-build elements are fixeddirectly onto the wall between wood bat-tens for plaster work. If an additional insu-lation layer is required, it has to be fixedfirmly onto the bare wall.
The wall is normally covered with dry-buildboards with a thickness of 12.5 cm whichare fixed onto the battens. The dry-buildboards are covered with the required wallfinish (wall paper, structural plaster, paint,tiles, etc.).
The dry-build wall heating and cooling sys-tems reduces the time of construction.
Due to the dry-build system, no humiditypenetrates the wall.
Contrary to floor surfaces, wall surfacesdo not represent a direct contact surface,so the surface temperature can be slightlyhigher during heating periods. For reasonsof comfort it is, however, recommended notto exceed an average surface temperatureof 40°C during heating periods. The maxi-mum temperature load of the wall finishmay reduce this limit. The maximum per-missible flow temperatures contained withinthe instructions of the dry-build boardmanufacturers must be observed.
As with underfloor heating, an incrementalheating test has to be carried out for wall
heating/cooling systems. This will confirmthat it functions correctly but is not intend-ed to dry the wall construction. Procedureand documentation must be carried out inaccordance with the dry-build board manu-facturer’s instructions.
1 Wall surface with thermal insulation
2 Wall surface without thermal insulation
Wall construction of adry-build system withthermal insulation(e.g. inner wall)
Brickwork
Battens for plaster work
Insulation
Pipe
Conducting strip
Dry-build element
Dry-build board
Wall finish
Wall construction of adry-build system without
thermal insulation(e.g. inner wall)
Brickwork
Battens for plaster work
PipeConducting strip
Dry-build element
Dry-build board
Wall finish
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 17/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 18/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 19/10819
“Cofloor” system industryfor heating/cooling
2
3
4
1
54
3
1
2
2
4
5
7, 8
7, 8
9
6
1 Surface heating and cooling systems forcommercial and industrial buildings arebecoming more and more important.The advantages of surface heating and
cooling systems in residential buildings canalso be used for industrial buildings.Oventrop offers high quality system com-ponents for a professional installation of theindustrial “Cofloor” system.
2 System components:1 Brass distributor/collector “Multidis SFI”
of modular construction, extendable upto a maximum of 20 heating circuits
2 Cap for closing the flow distributor and
return collector3 Console for fixing the brass distributor/collector
“Multidis SFI”4 Ball valve “Optiflex” for filling and venting
5 Ball valve “Optibal” for the isolation of the flow distributor
and return collector6 Compression fittings “Cofit S” 20 x 2 mm x G 1 collar nut 20 x 3 mm x G 1 collar nut for the connection of the PE-Xc pipes
“Copex” to the distributor/collector7,8 Composition pipe “Copipe” and press
fittings “Cofit P” for a quick and safeconnection of the distributor/collectoron the riser side
9 PE-Xc pipe “Copex” Diffusion tight pipe for the professio- nal installation in the Oventrop industrial
“Cofloor” system
3 Industrial hall
4 Distributor/collector “Multidis SFI”
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 20/10820
Floor construction/Standard constructionsBase mat, tacker and clamping rail system
3 4
1 2
5 6
The EN 1264-4 standard and the EnergySaving Directive describe the minimumrequirements regarding the thermal insula-tion of surface heating systems. Higher
demands can be defined by the specifyingengineer.The following standard constructions of thesurface heating system “Cofloor” with thebase mat NP-35, the base mat roll or thefolded board as pipe backing, thermal andsound insulation derive from this.
Effective thickness of insulation layer: 35 mm (both systems)Thermal conductivity group: 040 base mat NP-35 045 base mat roll/folded boardSound absorption: 28 dB base mat NP-35 29 dB base mat roll/folded boardOverall height: 54 mm base mat NP-35
35 mm base mat roll/folded boardElasticity under pressure: 2 mm base mat NP-35 3 mm base mat roll/folded boardMax. load: 5 kN/m² base mat NP-35 4 kN/m² base mat roll/folded boardScreed volume (both systems) with a pipecovering of: 45 mm (approx. 65 mm screed): approx. 60 l/m² 30 mm (approx. 50 mm screed): approx. 45 l/m²
1,2 Underfloor heating above a heatedroomInsulation layer according to DIN EN1264-4 with base mat, base mat roll or
folded board: 35 mmThermal resistivity: R ≥ 0.75 (m²K)/W
3,4 Underfloor heating above unheatedrooms, rooms heated at irregular inter-vals or on flooring in direct contact withthe groundInsulation layer according to DIN EN1264-4 with base mat, base mat roll orfolded board: 35 mmand expanded polystyrene, thermal con-ductivity group 040: 20 mmThermal resistivity: R ≥ 1.25 (m²K)/W
5,6 Underfloor heating of a flooring withoutside air from belowInsulation layer according to DIN EN1264-4 with base mat, base mat roll or
folded board: 35 mmand expanded polystyrene, thermal con-ductivity group 040: 50 mmThermal resistivity: R ≥ 2.0 (m²K)/WSealing of buildings according to DIN18195 below the insulation layer:approx. 2 mm
Example of a floor constructionaccording to points 3, 4(valid for both systems):hC = Floor covering, e.g. 10 mmhS = Screed, e.g. +65 mmhI = Insulation layer +35 mmh AI = Additional insulation +20 mmOverall height, e.g. 130 mm
hB
hDhZ
hE
hB
hDhZ
hE
hB
hDhZ
hE
hC
hS
hI
h AI
hC
hS
hI
h AI
hC
hS
hI
h AI
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 21/10821
Floor constructionStandard constructions
Dry-build system
1 2
5 6
3 4
Using the dry-build system as pipe backingand thermal insulation, the following stan-dard construction of the “Cofloor” surfaceheating is derived from the DIN EN 1264-4
standard and the Energy Saving Directive.Thickness of dry-build element: 25.0 mmEffective thickness ofinsulation layer: 17.5 mmThermal conductivity group: 035Max. load (dry-build element): 60 kN/m²Construction height ofdry flooring elements: 25.0 mm
1,2 Underfloor heating above a heatedroomInsulation layer according to DIN EN1264-4 with dry-build element: 25.0 mmand expended polystyrene035 DEO: 10.0 mmThermal resistivity: R ≥ 0.75 (m²K)/W
3,4 Underfloor heating above unheated
rooms, rooms heated at irregular inter-vals or on flooring in direct contact withthe groundInsulation layer according to DIN EN1264-4 with dry-build element: 25.0 mmand expended polystyrene035 DEO: 30.0 mmThermal resistivity: R ≥ 1.25 (m²K)/W
5,6 Underfloor heating of a flooring withoutside air from belowInsulation layer according to DIN EN1264-4 with dry-build element: 25.0 mmand expended polystyrene035 DEO: 55.0 mmThermal resistivity: R ≥ 2.0 (m²K)/WSealing of buildings according to DIN18195 below the insulation layer:
approx. 2 mmExample of a floor construction accord-ing to points 3, 4:hC = Floor covering, e.g. 10 mmhS = Screed, e.g. +25 mmhI = Insulation layer +25 mmh AI = Additional insulation +20 mmOverall height, e.g. 90 mm
hBhEhD
hB
hEhDhZ
hB
hDhZ
hE
hC
hS
hI
hC
hS
hI
h AI
hC
hS
hI
h AI
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 22/10822
Floor constructionStandard constructions
Base mat NP-R and industry systems
3 4
1 2
1,2 Underfloor heating above a heated orunheated room without insulation layerTogether with the corresponding levellingcompound, the system is laid directly onto
the existing flooring or the bare floor as acompound construction.- The manufacturer’s specifications of the
levelling compound must be observed.- The overall height is related to a com- pound construction on existing flooring or
the bare floor.- In systems with additional insulation
layers, the manufacturer’s specificationsof the levelling compound must be strictlyobserved (for instance regarding an in-
crease of the minimum covering).
3,4 Industrial floor heating in directcontact with the groundThe brass distributors/collectors “MultidisSFI” are used for the connection of heat-ing/cooling circuits in industrial surface
heating and cooling systems.The floor construction for the individualprojects is specified by the productionengineer and the structural engineer.
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 23/10823
Performance table for the rapid designBase mat NP and tacker system
PE-Xc pipes “Copex”, PE-RT pipes “Copert” and“Copipe” pipes, 14 x 2 mm
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 24/10824
Performance table for the rapid designBase mat NP and tacker system
PE-Xc pipes “Copex”, PE-RT pipes “Copert” and“Copipe” pipes, 16 x 2 mm, 17 x 2 mm
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 25/10825
Performance table for the rapid designDry-build system
“Copipe” pipes, 14 x 2 mm
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 26/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 27/10827
Information for all performance charts:
Due to minimal deviations, the performancecharts show average values. Thereforesurface heating systems with PE-Xc pipes“Copex”, PE-RT pipes “Copert” and
composition pipes “Copipe” sized 14 x2 mm, 16 x 2 mm and 17 x 2 mm can becalculated.
Verlegeabstand
in mm 50 100 150 200 250 300
W ä r m e s t r o m d i c h t e q [ W / m 2 ]
200
180
160
140
120
100
80
60
40
20
0
0 10 20 30 40 50 60 70 80
Heizmittelübertemperatur ∆ΘH [K]
Grenzkurve
Randzone
Grenzkurve
Aufenthaltszone
und Bad
Verlegeabstand
in mm 50 100 150 200
W ä r m e s t r o m d i c h
t e q [ W / m 2 ]
200
180
160
140
120
100
80
60
40
20
0
0 10 20 30 40 50 60 70 80
Heizmittelübertemperatur ∆ΘH [K]
250
300Grenzkurve
Randzone
Grenzkurve Aufenthaltszone
und Bad
Performance chart
for RλC = 0.10 (m²·K)/W
Floor covering: e.g. carpet,concrete, calcium sulphate or anhydritescreed, pipe covering 45 mm
Performance chart
for RλC = 0.15 (m²·K)/WFloor covering: e.g. thick pile carpet,concrete, calcium sulphate or anhydritescreed, pipe covering 45 mm
H e a t f l o w d e n s i t y q [ W / m ² ]
Laying distancein mm
Heating medium excess temperature ΔΘFluid [K]
Limiting curveFringe area
Limiting curveResidential areabathroom
H e a t f l o w d e n s i t y q [ W / m ² ]
Laying distancein mm
Heating medium excess temperature ΔΘFluid [K]
Limiting curve
Fringe area
Limiting curveResidential areabathroom
Performance charts for different floor coveringsPE-Xc pipes “Copex”, PE-RT pipes “Copert” and “Copipe” pipes
Base mat NP and tacker system
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 28/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 29/10829
Pipe distance RA = 0.050 m
Heating medium excess temperature in K
Limiting curve dT:9K Limiting curve dT:15K
Pipe distance RA = 0.050 m
H e a t f l o w d e n s i t y i n W m 2
Pipe distance RA = 0.075 m
Limiting curve dT:9K Limiting curve dT:15K
Heating medium excess temperature in K
Pipe distance RA = 0.075 m
H e a t f l o w d e n s i t y i n W m 2
Pipe distance = 0.100 m
Limiting curve dT:9K Limiting curve dT:15K
Heating medium excess temperature in K
Pipe distance RA = 0.100 m
H e a t f l o w d e n s i t y i n W m 2
Performance charts for different floor coveringsPE-RT pipes “Copert”
Base mat NP-R system
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 30/10830
Limiting curve dT:9K Limiting curve dT:15K
Heating medium excess temperature in K
Pipe distance RA = 0.150 m
H e a t f l o w d e n s i t y i n W m 2
Limiting curve dT:9K Limiting curve dT:15K
Heating medium excess temperature in K
Pipe distance RA = 0.200 m
H e a t f l o w d e n s i t y i n W m 2
Pipe distance RA = 0.150 m
Pipe distance RA = 0.200 m
Pipe distance RA = 0.250 m
Limiting curve dT:9K Limiting curve dT:15K
Heating medium excess temperature in K
Pipe distance RA = 0.250 m
H e a t f l o w d e n s i t y i n W m 2
Performance charts for different floor coveringsPE-RT pipes “Copert”
Base mat NP-R system
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 31/10831
Stainless steel distributors/collectors “Multidis SF”for surface heating and cooling system
The Oventrop stainless steel distributors/ collectors “Multidis SF” allow a central dis-tribution of the heating or cooling water tothe different circuits of each dwelling unit.
The Oventrop distributors/collectors aredesigned for surface heating and coolingsystems with circulation pump.
The supply and the return pipe may beconnected either on the left or right handside.The brackets allow the fixing of the distribu-tor/collector in the cabinet or directly ontothe wall.When using a heat meter, its lengths haveto be taken into consideration when choo-sing the cabinet.To enlarge the depth of the cabinet, theframe and the door have to be pulled out.
The ball valve DN 25 with temperature sen-sor connection M 30 x 1, item no. 140 67 08,can be used at the supply of the stainlesssteel distributor/collector “Multidis SF”.Hydronic balancing of the installation iscarried out with the help of the integratedinserts of the return collector.
1 Stainless steel distributor/collector “Multi-dis SF” with integrated flow measuring andregulating devices 0-5 l/min. in the flowdistributor. As for the distributor/collector, item no.140 43, the calculated flow rate is set at thehandwheel of the flow measuring andregulating device. The set value can beread off the viewing glass with scale(0-5 l/min.). Each heating/cooling circuitcan be isolated without modification of theset flow rate which means that the set flowrate is re-stored after reopening an isolatedheating/cooling circuit. The functions “set-ting” and “isolation” are thus autonomous.
2 Stainless steel distributor/collector “Multi-dis SF” with integrated regulating inserts inthe flow distributor. As for the distributor/collector, item no.140 45, regulation is carried out accordingto a chart (see technical information).The calculated flow rate is set at the hiddenstem of the regulating insert. A reproduciblepresetting is possible.
Oventrop offers a calculation programmefor the design of a surface heating systemwith composition pipe “Copipe”. The valveinserts M 30 x 1.5 in the return collec-tor which are convertible to thermostatic
operation allow the individual room tem-perature control prescribed in the EnergySaving Directive. The Oventrop electro-thermal actuators and room thermostats orthermostats with remote control which areavailable as accessories, are used for thispurpose.
3 Dimensions “Multidis SF”
1 2
3
Item no. Outlets Length LLength with
ball valves e. g. 140 64/65 83
140 43 52 2 190 mm 263 mm
140 43 53 3 240 mm 313 mm
140 43 54 4 290 mm 363 mm
140 43 55 5 340 mm 413 mm
140 43 56 6 390 mm 463 mm
140 43 57 7 440 mm 513 mm
140 43 58 8 490 mm 563 mm
140 43 59 9 540 mm 613 mm140 43 60 10 590 mm 663 mm
140 43 61 11 640 mm 713 mm
140 43 62 12 690 mm 763 mm
Actuator
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 32/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 33/10833
Hydronic balancing of the heating circuitsRegulation with flow measuring and regulating device
1
3
2
4
As with any heating system, a hydronicbalance according to DIN 18380 is alsorequired for the surface heating system.
Regulation of the surface heating circuit iscarried out at:Stainless steel distributor/collector“Multidis SF”, item no. 140 43 52 to140 43 62,via the flow measuring and regulating de-vices at the flow distributor.
Setting is carried out whilst the circulationpump is in operation.
All valves of the heating circuit are to befully open.1 Lift the locking ring until it clicks into
position.2 Wind up locking cap.3 Set the calculated flow rate by turning the
red handwheel of the first flow measuringand regulating device.
The set value can be read off at the redindicator ring inside the viewing glass.The scale shows values between 0 and5 l/min. Carry out setting of all heatingcircuits.
The first values are checked andreadjusted if required.
4 With the setting being completed, closelocking cap until stop. Protect setting ofthe flow measuring and regulating de-
vices by pushing the locking ring downuntil it clicks into position.
Isolation and openingEach heating circuit can be isolated with-out modification of the set flow rate whichmeans that the set flow rate is restoredafter reopening an isolated heating/cooling
circuit. The functions “setting” and “isola-tion” are thus autonomous.
1 Isolation:The heating circuit is closed by turning thered handwheel clockwise until stop.
2 Opening:Turn the red handwheel anticlockwise untilstop. The flow measuring and regulatingdevice is opened and the set flow rate isrestored.
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 34/10834
Hydronic balancing of the heating circuitsRegulation with regulating inserts
Regulation of the surface heating circuit iscarried out at:
Stainless steel distributor/collector“Multidis SF”, item no. 140 45 52 to140 45 62andStainless steel distributor/collector“Multidis SFB, item no. 140 44 52 to140 44 62
via the regulating inserts at the return col-lector:
1 Unscrew black cap, use an Allen key(size 5) if necessary.
2 Close regulating stem by turning the Allenkey (size 5) clockwise.
Then, open regulating stem to the calcu- lated presetting by turning it anticlock- wise. (Example: Calculated presetting PSR =
2.5 – open stem by 2.5 turns, seepressure loss chart)
3 Turn black setting screw clockwise withan Allen key (size 6) up to the regulatingstem. This way, the setting can be easilylocated again, if for instance the heatingcircuit is closed at a later time by use ofthe regulating stem.
4 Replace black cap and tighten with an Allen key (size 5) if necessary.
Repeat the same process for all heatingcircuits.
210
8
10
104
2
10
2
3
6
4
2
3
10
1
3
2
4
6
8
0.8
0.6
0.4
0.3
2
3
8
6
4
3
2
103
210
2
3
4
6
8
8
6
4
3
2 3 4 6 81 2 3 4 6 8 1086432
1 1.5 2 2.5 3 3.5 4.5 54
m a x
.
3
Umdrehungen
D r u c k v e r l u s t ∆ p [ m b a r ]
D r u c k v e r l u s t ∆ p [ P a s c a l ]
Flow of heating water mFluid [kg/h]
1 2
3 4
SW 5
SW 6
Pressure loss chartfor regulating inserts at the return collectorof the stainless steel distributor/collector“Multidis SF”. Valve inserts of the flow distributor fullyopen.
Turns
P r e s s u r e l o s s ∆ p [ m b a r ]
P r e s s u r e l o s s ∆ p P a s c a l
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 35/10835
Brass distributor/collector “Multidis SFI“ forindustrial surface heating and cooling systems
Surface heating and cooling systems forcommercial and industrial buildings arebecoming more and more important. Theceiling heights of these buildings are usu-
ally very high and therefore an even andeconomical distribution of the required tem-perature is needed. Utilising the large sur-face area together with a favourable verticaltemperature profile fulfils this demand.
The integration of the surface heatingsystem within the ground floor allows aninterior design that is free and flexible.Conventional visible heating systems haveto be cleaned and serviced regularly, butindustrial surface heating systems do norequire individual maintenance. Surfaceheating in commercial and industrial build-ings is therefore a heat distribution systemwhich is economical and energy efficientand with technical effort it can also be usedfor cooling.
1 The brass distributors/collectors “Multi-dis SFI” allow a central distribution of theheating or cooling water to the differentcircuits of an industrial surface heating/ cooling system. It is recommended to equipthe distributors/collectors with ball valvesDN 50. They allow the isolation of the sup-ply and return pipe, e.g. for maintenancework. Consoles with pipe clamps (includingsound insulation supports) allow a fixing ofthe distributor/collector onto the wall.
The ball valve at the flow distributor and theregulating valve at the return collector allowthe isolation of each heating circuit.
2 Summary with system componentsFive different distributor modules with two
to six heating circuit connections allow anindividual combination of up to 20 circuits.The individual modules are interconnectedwith flat seals. The distributor/collectorends are closed with plugs.
3 PE-Xc plastic pipes “Copex” sized 20 x 2mmand 26 x 3 mm can be connected to theheating circuit connections of the brassdistributor/collector “Multidis SFI” with cor-responding compression fittings. The pipesare made of cross-linked polyethylene andare oxygen tight according to DIN 4726.
The sheltered oxygen barrier protects thePE-Xc plastic pipes “Copex” against dam-ages on site.
4 Hydronic balancing of the individual sur-
face heating circuits has to be carried out inaccordance with the VOB DIN 18380 stand-ard. Regulation is carried out at the regula-ting valves integrated in the return collec-tor of the “Multidis SFI”.
1
2
3
4
Ball valve
Ball valve“Optiflex” ball valve
Console
“Optiflex” ball valve
Distributor/collectorfor 4 circuits
Distributor/collectorfor 4 circuits
Cap2-fold
Valve stem Cap
Bonding agent
Oxygen barrier
Bonding agent
PE-Xc
PE-Xc
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 36/10836
Flow temperature control of surface heating systemsControl unit “Regufloor H” and
boiler connection system “Regumat F-130”
Economy and comfort of a surface heatingsystem can only be achieved if the correctlycalculated pipe layout and floor constructionis adhered to. Moreover, a temperature and
flow control of the heating medium adaptedto the surface heating must be taken intoconsideration.The main points of the regulation are theprovision of a permissible flow temperatureof the heating medium (this should beseparate from the boiler regulation) and thedistribution of mass flow in the individualheating circuits of the stainless steel dis-tributor/collector.
1 Control unit “Regufloor H”Fixed value control unit for the connectionto the stainless steel distributors/collectors“Multidis SF” for surface heating which alsosupply a radiator circuit. The unit regulatesthe flow temperature of the heating mediumto a constant value (fixed value control) by
adding some of the return flow water of thecollector with a temperature controller withcontact sensor and a three-way valve.
Control range 20-50°CMax. operating temperature 50°CMax. operating pressure 6 barkvs value 4.0
The medium in the heating circuits of thesurface heating system is circulated by anelectronically controlled pump. To protectthe surface heating against overheating, forinstance in case of failure of the temperaturecontroller, the control unit is equipped with amodule which switches the pump off.
2 The advantage of the control unit“Regufloor H” is the facility to integrate
the flow tem-perature control of a surfaceheating into the heating circuit of a radiatorsystem. The illustration displays theconnection to the supply and return of theradiator system.
3 Flow temperature control can be carriedout directly at the heating generator by usingthe Oventrop boiler connection system“Regumat F-130”. Flow temperature controlis carried out by a temperature controllerwith immersion sensor and a three-wayvalve.By using this solution, the whole circuit ofa heating system can be operated with theflow temperature adapted to the surfaceheating.
1
2
3
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 37/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 38/10838
Flow temperature control of surface heating systemsControl unit “Regufloor HX“ with system separation
Years of experience have shown that un-favourable conditions in surface heatingsystems with plastic pipes may lead to cor-rosion problems caused by a penetration of
oxygen.In pure radiator systems, such corrosionproblems normally do not entail problemsas they may deposit in a number of sta-bilization zones.
In surface and especially underfloor heatingsystems, such deposits could impair theflow behaviour in the underfloor circuit. Mal-functions or even a breakdown of the circuitcould be a result.
1 The heat exchanger of the control unit“Regufloor HX” divides the system into aprimary and secondary circuit. The primarycircuit is the heating system and the secon-dary circuit is the surface heating circuit.This way, surface heating circuits with pipes
without oxygen barrier can be connected.These can be found in old installations or,system related, in new installations. Due tothe separation, a penetration of oxygen fromthe surface heating circuit into the boilercircuit is avoided. The other way round, apenetration of possible corrosion productsfrom the boiler circuit into the surface heat-ing circuit and thus a silting-up of the pipesis also avoided.
The regulating valve on the primary sideserves to control the set flow temperature.The temperature is detected with the help ofan immersion sensor on the secondary side.
The Grundfos pump “ALPHA” electronicallycontrols the pump output according to the
current heating water demand. Due to itsbronze body, the pump is corrosion resist-ant.
2 Control unit “Regufloor HX” for flow tem-perature control in surface heating systemsand for the separation of heating circuitsinto a primary and a secondary circuit incombination with the stainless steel dis-tributors/collectors, item no. 140 43 and140 45 consisting of:
Connection fittings, regulating valve, tem-perature controller with immersion sensor,heat exchanger, pressure gauge, dia-phragm safety valve, diaphragm expansiontank, electronically controlled pump.Installation is carried out on the left handside of the distributor/collector.
3 Installation exampleControl unit “Regufloor HX” with stainlesssteel distributor/collector in a surface-mounted cabinet.
1
2
3
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 39/10839
“Cofloor” system extension for surface coolingControl unit “Regufloor HC” for
alternate operation of heating and coolingfor all laying systems
The systems “Base mat”, “Tacker”, “Dry-build” and “Clamping rail” are also suit-able to generate a comfortable roomtemperature on warmer days of the year,
when cooling water rather than heatingwater is fed through the pipework. Theterm “thermal comfort” for room coolingis explained further in DIN 1946 part 2. Itis also described as soft or quiet cooling.This cooling system is not accompanied bydraughts, high air movements, dust gen-eration or high noise levels typical of theclassic air cooling methods. In addition, theenergy exchange between humans and acooling surface is through radiation, whichis similar to the thermal balance of humanbeings.
1 If the system is operated alternately withheating or cooling water, then the permit-ted flow temperature must be checkedfor the surface heating as well as for the
surface cooling operation. Oventrop offersthe control unit “Regufloor HC” for thispurpose, which will keep the temperatureof the medium at a constant set value evenduring cooling operation by mixing somereturn flow water. The three-way valve isoperated here by an electromotive actua-tor 24 V (0-10 V) which receives its signalsfor heating and cooling from an electronicroom thermostat.
2 The flow temperature regulating set foroutside temperature guided heating andcooling via the corresponding surface heat-ing and cooling systems enables an auto-matic changeover from heating to coolingfor each application.
Flow temperature regulating set consistingof:Climate controller heating/coolingOutdoor sensorFlow temperature sensorRoom humidity measuring transducerMemory stickElectrothermal actuatorElectromotive actuatorElectric sensor attached to pipe
3 The controller heating/cooling is designedfor a universal application in heating andcooling systems, e.g. for flow temperaturecontrol in surface heating and cooling sys-tems. With integrated measuring, controland timed function via two PI controllersand preset parameters for an easy initial
operation. The remote control can be usedfor certain applications (remote control ofthe operating mode, correction of the nomi-nal values and setting of the clock).
4 The room humidity measuring transducercalculates the dew point of the air humidity.In connection with the controller heating/ cooling, it avoids condensation of the pipe-work and chilled surfaces.
1
2
4
3
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 40/10840
“Cofloor” system extension for surface coolingHeating surface regulation for heating and cooling
Example of surface heating and cooling system
Even in surface cooling systems, the En-ergy Saving Directive calls for automaticdevices allowing an individual room tem-perature control. For this purpose, the
actuators mounted on the stainless steeldistributors/collectors receive their signalsfrom electronic room thermostats which aresuitable for switching over from heating tocooling operation.
1 The changeover from heating to cooling iscarried out via the controller heating/cool-ing. It is, amongst others, connected to theoutdoor sensor, the flow temperature sen-sor as well as the room humidity measuringtransducer. The required room temperatureis calculated with the help of the measuredvalues of these system components and iscontrolled via the electromotive actuator.The controller heating/cooling also trans-mits the operating mode “changeover fromheating or cooling” to the electrothermal
actuator for the integration of the heating orcooling generator.
The switch-over signal is also transmittedto the connection system and to the corres-ponding room thermostats. Furthermore, adew point control can be used to protectthe chilled surfaces from condensation.
2 The room thermostat heating/cooling isused for individual room temperature con-trol. It has one entry for the operating mode“changeover from heating or cooling”.
3 The connection system is mounted in thecabinet of the surface heating/cooling andserves the distribution of electric signalsand the power supply of the room thermo-stats and actuators.
1
2 3
Outdoor sensor1153051
Connection system in the underfloorheating distributor/collector1152045230 VAC6 channels Heating/coolingController –
Heating/cooling1153041
ConversionvalveHeating/cooling
C/O
N/RContact sensor1152050
Room humiditymeasuringtransducer1141960
Room thermostatHeating/cooling1152063
Thermalactuator1012485
Dew pointcontrol1141951
SwitchDew pointactivation
Room thermostatHeating/cooling1152063
Temperature
Humidity
Room thermostatHeating/cooling1152063
Room thermostatHeating/cooling1162063
Underfloor heatingdistributor/collector
Living room
Bedroom
Children’s room
Bathroom
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 41/10841
Heating cicuit regulation of surface heating systems Actuators and room thermostats
Wireless controls
3 4
1 2
5
7
6
The Energy Saving Directive calls for a cen-tral flow temperature control of the heatingmedium (e.g. via the control unit “Regu-floor”) and for an individual selfacting room
temperature control e.g. with room thermo-stats and actuators.
Such regulating systems even out any tem-perature differences (e.g. short opening ofa window).
The Oventrop room thermostats and actua-tors fulfil these requirements. Wired andwireless devices are available for this pur-pose. The wired items are regulating com-ponents which work as two point (opened/ closed) or proportional (0-10 V) actuators.
1 Room thermostat or room thermostat-clock 230 V or 24 V with thermal actuator230 V or 24 V for room temperature controlvia the individual heating circuits. By usingthe room thermostat-clock, time controlled
temperature changes can be set.2 Distributor/collector “Multidis SF” inside acabinet with mounted electrothermal actua-tors. The wired connection to the roomthermostats is made via a plug-in rail whichis situated above the distributor/collector.
3,4 The wireless individual room tempera-ture control is carried out with a roomthermostat or a room thermostat-clock withwireless transmitter and the 4 or 6 channelreceiver. The two point actuators housed inthe cabinet (see illustr. 3) are connected tothe receiver. Apart from being suitable fornew buildings, existing buildings can alsobe upgraded with the wireless temperaturecontrol.
It is also possible to switch from heating tocooling operation.
5,6 For a wired individual room tempera-ture control, Oventrop offers proportionalactuators (0-10 V) which work with a 24 Vsupply voltage. The nominal value range ofthe electronic room thermostat can be lim-ited by use of the hidden limiting elements.The proportional actuator has the facility toreverse the actuation. This feature isnecessary for surface cooling.
7 Wireless receiver with time switch for 8channels. Application in connection withdistributors/collectors with actuators.8-channel time switch for the timed controlof up to 8 independent zones. Program-ming of the time switch and adaptation of
the transmitters is possible with removedcover.
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 42/10842
Accessories for stainless steel distributors/collectorsDouble regulating and commissioning valves for hydronic balancing
Heat meter connection set
2
If the room temperature in partial areas ofthe heating system is reduced, it must beensured that the other areas are not under-or oversupplied. This condition is governed
by the pressure drops in the pipe systemand the installed valves and can only bedetermined by a heat demand and pipe-work calculation. Oventrop offers relevantcalculation programmes which amongstother, will deliver the settings of the valvesfor hydronic balancing not only for theregulation of mass flow to the stainlesssteel distributors/collectors but also of theindividual heating circuits connected to thestainless steel distributors/collectors.
1 Example of a two pipe heating systemwith surface heating areas and radiatorsconnected to the risers. Balancing of themass flow to every stainless steel distribu-tor/collector with a double regulating valve“Hycocon VTZ”.
2 The “Hycocon VTZ” is a double regulatingand commissioning valve for the manualhydronic balance between several dis-tributors/collectors or risers. The infinitelyadjustable presetting is lead sealable andlockable. Available with female or malethread. The balanced mass flow can easilybe controlled with the help of the flow-meter “OV-DMC 2”.
3 If it is required to measure the heat con-sumption of separate distributor circuits,for instance of separate dwellings, it is pos-sible to install a heat meter connection setin front of the corresponding distributor/ collector. These are offered by Oventroptogether with the double regulating andcommissioning valves “Hycocon VTZ”. Forthe connection of the supply and returnpipe, the connection set is available inangle or straight pattern. The connectionset is suitable for heat meters with a lengthof 110 mm (G 3/4 male thread) and 130 mm(G 1 male thread).
4, 5 Depending on the space available, the“Hycocon VTZ” allows various installationpositions, for instance turning the heatmeter by 90° if the depth is not sufficient.
3
4 5
1
“Hydrocontrol ATR”
“Hydromat DTR”
Illustration:
Radiator and surfaceheating combination of a lowtemperature heating systemwith a max. flow temperatureof 55 °C.
“Hycocon VTZ”
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 43/10843
Accessories for stainless steel distributors/collectorsDifferential pressure regulators for hydronic balancing
Heat meter connection set
2
In addition to the manual hydronic balan-cing of the distributors/collectors by usingthe double regulating and commission-ing valves, a hydronic balance during low
demand periods can also be achievedwith the help of the automatic differentialpressure regulators “Hycocon DTZ”. Thisensures that the valves of the individualheating circuits are protected from unac-ceptably high differential pressure.
1 Example of a two pipe heating systemwith radiators and surface heating areasconnected to the risers. A differential pres-sure regulator “Hycocon DTZ” is installedin front of every surface heating area. Theregulator has to be set to a nominal valueto be determined (e.g. 150 mbar). The regu-lator will maintain a constant differentialpressure between supply and return withina necessary proportional band.
2 The installation of an automatic differen-tial pressure regulator “Hycocon DTZ”allows that the distributor units can operateindependently. The permissible differentialpressure between supply and return can beset and locked at the “Hycocon DTZ”. A change in the system pressure has there-fore no influence on the heating circuits ofthe distributor units of the surface heating. A manual balance is not required.
3,4 To install the differential pressure regu-lator together with a heat meter connectionset, Oventrop offers connection sets inangle or straight patterns (installation sizes110 mm and 130 mm).
3
4
1
“Hydrocontrol ATR”
“Hydromat DTR”
Illustration:
Radiator and surfaceheating combination of a lowtemperature heating systemwith a max. flow temperatureof 55 °C.
“Hycocon DTZ”
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 44/10844
Dwelling station“Regudis W-HTF”Integration of surface heating and cooling
The station “Regudis W-HTF” which ismounted on a fixing sheet is a completelypre-assembled and leak tested unit withconstant or variable temperature circuit.
The station does not only supply a dwellingwith hot water for the radiators or under-floor heating, but also with potable water.
1 Station “Regudis W-HTF” as completemodel for a dwelling with underfloor heating,consisting of:- “Regudis W-HTF” dwelling station, item no. 134 11 40- Connecting block (8 control zones) for room thermostats
and actuators, item no. 140 10 81- Electrothermal actuator (2 point), closed with current off, 230 V, item no. 101 28 15- Cabinet – extended model for the direct connection of the dwelling
station and the underfloor heating
distributor/collector Dimensions: Width 700 mm Height 1210 – 1335 mm Depth 115 – 180 mm Steel, galvanized, frame and door white
lacquered, removable screen, item no. 134 11 75- Derivative temperature control set to maintain the flow temperature in the
“Regudis W-HTF” station to guarantee aquick supply of hot potable water outsidethe heating period,
item no. 134 11 90,- Ball valve connector block 7 ball valves mounted in a bracket for the
isolation of all connections of the“Regudis W-HTF” station.
Connections to the pipework: Rp 3/4 female, item no. 134 11 80- Connection set stainless steel dis- tributor/collector for the connection of the dwelling station
“Regudis W-HTF” to the stainless steeldistributor/collector “Multidis SF”,
item no. 134 11 87- “Multidis SF” 8-fold stainless steel distributor/collector
for surface heating systems with inte- grated flow measuring and regulating
devices, item no. 140 34 58
2 System illustration
1
2
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 45/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 46/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 47/10847
“Unibox vario”“Unibox E vario”
“Unibox vario”Installation set (basic model) for tempera-ture limitation of heating surfaces withreturn temperature limiter.
Temperature range: 10-40°C factory setting(return temperature), may be increased to50°C by cancelling the limitation (40°C).Room temperature: depending on the usedcontrol.
The basic model can be converted to:
“Unibox vario” with thermostat withremote control “Uni FH”The control is mounted on the vertical valveconnection inside the “Unibox”. The capil-lary towards the room temperature sensorcan be led downwards out of the “Unibox”,e.g. through an empty pipe.
or
“Unibox vario” with electric room ther-mostat and actuatorThe actuator is mounted on the vertical con-nection inside the “Unibox” (when using anelectromotive actuator, the stem extension,item no. 102 26 98, is additionally required).The connecting cable towards the roomthermostat can be led downwards out of the“Unibox”. Laying through an empty pipe isadvantageous.
( Attention: In case of installation in thebathroom, the regulations for electricinstallations in humid areas have to be ob-served.)
“Unibox E vario”Installation set (basic model) for tempera-ture limitation of heating surfaces withreturn temperature limiter (hidden).
Temperature range:20-40°C (return temperature)Room temperature: depending on the usedcontrol.
The basic model can be converted to:
“Unibox E vario” with thermostat withremote control “Uni FH”The control is mounted on the vertical valveconnection inside the “Unibox”. The capil-
lary towards the room temperature sensorcan be led downwards out of the “Unibox”,e.g. through an empty pipe.
or
“Unibox E vario” with electric roomthermostat and actuatorThe actuator is mounted on the verticalconnection inside the “Unibox”. The con-necting cable can be led towards the roomthermostat through a hole to be drilledon the outer wall of the “Unibox”. Layingthrough an empty pipe is advantageous.
( Attention: In case of installation in thebathroom, the regulations for electricinstallations in humid areas have to be ob-
served.)
Surface heating
S u p p l y
R e t u r n
Individual roomtemperature con-trol with thermostatwith remote control“Uni FH“
Surface heating
S u p p l y
R e t u r n
Individual roomtemperature con-
trol with electricroom thermostatand acuator
Surface heating
S u p p l y
R e t u r n
Individual roomtemperature con-trol with thermostatwith remote control
“Uni FH“
Surface heating
S u p p l y
R e t u r n
Individual roomtemperature con-trol with thermostatwith remote control“Uni FH“
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 48/10848
ApplicationInstallation and assembly
Appl ication:The different models of the “Unibox” aresuitable for the operation of a surface heat-ing system in rooms with a heating surface
up to 20 m². They are designed for the con-nection of one heating circuit. When usingpipes with an inner diameter of 12 mm, alength of 100 m must not be exceeded.It is to be observed that the supply andreturn pipe are laid alternately side by side(see e.g. the spiral laying in the installationsketches pages 2, 3 and 4). A constantheating of the floor is thus guaranteed.
The “Unibox TSH” / “Unibox T” /“Unibox E T” / “Unibox E TC” allows thecontrol of the room temperature via the sur-face heating system. It is used in combina-tion with a low temperature heating systemwith a maximum flow temperature of 55°C.
The “Unibox RTL” / “Unibox E RTL” allows the temperature limitation of heatingsurfaces with return temperature limiter.The room temperature is still controlled viathe radiator. Installation is carried out incombination with a radiator heating with amaximum flow temperature of 70°C.
The “Unibox plus” / “Unibox E plus” / “Unibox vario” / “Unibox E vario” allowsthe individual room temperature controlwith thermostatic valve and the tem-perature limitation of heating surfaces withreturn temperature limiter. As for the “Unibox RTL”, installation iscarried out in combination with a radiatorheating with a maximum flow temperatureof 70°C.
Installation and assembly:
For a simple installation of the pipes in thewall, Oventrop offers a pipe conduit unitsized to the depth of the “Unibox”/ “Unibox E”.Installation may be carried out easily.The pipe conduit unit and the installationset are fixed in the wall (see illustr. 1 instal-lation sketch). The heating pipes are laidaccording to the installation instructions.
Important:The “Unibox” always has to be installedbehind the surface heating circuit, i.e.in the return pipe. The direction of flowhas to be observed (illustr. 2).
For the connection to the valve, Oventropoffers suitable compression fittings. The
pipe conduit unit is closed and plastered.The fixing channel is closed with the coverplate. Control is carried out via the thermo-stat which is easily accessible. Care shouldbe taken that the thermostat is not influ-enced by other heat sources.
- Do not install near other heat sources,e.g. additional radiators (illustr. 3).
- Protect thermostat from direct sunlight(illustr. 4).
- Do not install at a location exposed todraught.
Example of installation for two surfaceheating circuits:In case of heating surfaces exceeding 20m²and a pipe length of more than 100 mper heating circuit, it is recommended to
connect two heating circuits of the samesize to the “Unibox” (illustr. 5). The installa-tion is then carried out by use of the Oven-trop “h” fitting, item no. 102 87 50 and thefitting item no. 101 63 04 or the Duo con-nection piece.
“Unibox E plus”1 “Unibox plus”
Wall box unit
Thermostat “Uni RTLH”
Prsettable valve with
thermostat “Uni LH”
Thermostat
Pipe conduit unit
Valve with presettableinsert and integrated
return temperature limiter
2
3
5
4
Surface heating
S u p p l y
R e t u r n
Surface heating
S u p p l y
R e t u r n
Correct Wrong
Wrong Wrong
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 49/10849
CabinetsInstallation instructions/Dimension chart
Recommendations for cabinets:
Cabinet item no. 140 11 51, no. 1, inner width: 560 mm Cabinet item no. 140 11 53, no. 3, inner width: 900 mm
Cabinet item no. 140 11 52, no. 2, inner width: 700 mm Cabinet item no. 140 11 54, no. 4, inner width: 1200 mm
L1 L2 L2 L3 L4 L5 L5
Number Length with Length with Length with Length with Length with Length with
Item of Length ball valve ball valve heat meter heat meter control unit control unit
no. heating DN 20 DN 25 connection set connection set and ball and ball circuits Angle pattern Straight pattern valve valve DN 20 DN 25
140 43 52 2 190 mm 245 mm 270 mm 377 mm 544 mm 560 mm 585 mm
140 43 53 3 240 mm 295 mm 320 mm 427 mm 594 mm 610 mm 635 mm
140 43 54 4 290 mm 345 mm 370 mm 477 mm 644 mm 660 mm 685 mm
140 43 55 5 340 mm 395 mm 420 mm 527 mm 694 mm 710 mm 735 mm
140 43 56 6 390 mm 445 mm 470 mm 577 mm 744 mm 760 mm 785 mm
140 43 57 7 440 mm 495 mm 520 mm 627 mm 794 mm 810 mm 835 mm
140 43 58 8 490 mm 545 mm 570 mm 677 mm 844 mm 860 mm 885 mm
140 43 59 9 540 mm 595 mm 620 mm 727 mm 894 mm 910 mm 935 mm
140 43 60 10 590 mm 645 mm 670 mm 777 mm 944 mm 960 mm 985 mm
140 43 61 11 640 mm 695 mm 720 mm 827 mm 994 mm 1.010 mm 1.035 mm
140 43 62 12 690 mm 745 mm 770 mm 877 mm 1.044 mm 1.060 mm 1.085 mm
G 3/4
L 2
L 1
50
m a x . 9 1
2 0 0
G 1
G 1
L 3
138 L 1
53 101
G 3/4
1 3 0 x G 1
1 1 0 x G 3 / 4
5 0
1 1 4
2 0 0
8 0
50
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 50/10850
Recommendation for surface-mounted cabinets:
Cabinet item no. 140 11 71, no. 1, inner width: 600 mm Cabinet item no. 140 11 73, no. 3, inner width: 1000 mm
Cabinet item no. 140 11 72, no. 2, inner width: 750 mm Cabinet item no. 140 11 74, no. 4, inner width: 1250 mm
Surface-mouted cabinetsInstallation instructions/Dimension charts
Number
of heating
circuits
Item
no.
L1
Length
L2
Length
with angle
pattern set
L3
Length
with heat meter
connection set
Angle pattern
L4
Length with
control unit
and angle
pattern set
2
3
4
5
6
7
8
9
10
11
12
140 43 52
140 43 53
140 43 54
140 43 55
140 43 56
140 43 57
140 43 58
140 43 59
140 43 60
140 43 61
140 43 62
L 2
104 L 1
53
G 3/4
67
2 0 0
1 1 5
2 0 0
50
190
240
290
340
390
440
490
540
590
640
690
320
370
420
470
520
570
620
670
720
770
820
377
427
477
527
577
627
677
727
777
827
877
636
686
736
786
836
886
936
986
1036
1086
1136
m a x .
9 1
L 3
138 L 1
53 101
G 3/4
1 3 0 x G 1
1 1 0 x G 3 / 4
5 0
1 1 4
2 0 0
8 0
50
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 51/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 52/10852
Sample form“Cofloor” material list
Red: Recommended laying distances in the
Laying Required pipe Residential area Bathroomdistance per m2 of Residential area Fringe area
LD heating surface 14 x 2 mm 16 x 2 mm 14 x 2 mm 16 x 2 mm 14 x 2 mm 16 x 2 mm
50 mm 20 m / m2
100 mm 10 m / m2
150 mm 6.7 m / m2
200 mm 5 m / m2
250 mm 4 m / m2
300 mm 3.3 m / m2
The minimum bending radii of the PE-Xc pipes “Copex”, the PE-RT pipes “Copert” and “Copipe HK”-pipes must be observed. If necessa-ry, the laying distance has to be increased where return loops are laid.
Article
Base mat NP 35
Edge isolating strip
Item no.
140 22 10
140 20 90
per m2
1.00
0.04
Laying distance 5 cm “Copipe” pipe 16 x 2 mm 150 01 55 20.00
Laying distance 10 cm “Copipe” pipe 16 x 2 mm 150 01 55 10.00
Laying distance 15 cm “Copipe” pipe 16 x 2 mm 150 01 55 6.67
Laying distance 20 cm “Copipe” pipe 16 x 2 mm 150 01 55 5.00
Laying distance 25 cm “Copipe” pipe 16 x 2 mm 150 01 55 4.00
Laying distance 30 cm “Copipe” pipe 16 x 2 mm 150 01 55 3.33
Material list per square meter
(also applies for pipes 14 x 2 mm)
Base mat system “Cofloor”
Composition pipe “Copipe”
Plastic pipe “Copex”
Article
Base mat NP 35
Edge isolating strip
Item no.
140 22 10
140 20 90
per m2
1.00
0.04
Laying distance 5 cm “Copex” pipe 16 x 2 mm 140 01 51 20.00
Laying distance 10 cm “Copex” pipe 16 x 2 mm 140 01 51 10.00
Laying distance 15 cm “Copex” pipe 16 x 2 mm 140 01 51 6.67Laying distance 20 cm “Copex” pipe 16 x 2 mm 140 01 51 5.00
Laying distance 25 cm “Copex” pipe 16 x 2 mm 140 01 51 4.00
Laying distance 30 cm “Copex” pipe 16 x 2 mm 140 01 51 3.33
Accessories
Expansion strip
Protection pipe
Round profile PE foam
Pipe guiding elbow
Marker point for screed measurement
Coil unwinder
Compression fitting
Floor level distributor/collector 5-fold
Item no.
140 20 91
150 11 84
140 20 92
140 90 85
140 90 90
140 20 96
150 79 75
140 43 55
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 53/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 54/10854
Sample formPressure test record of the Oventrop surface heating
and cooling system “Cofloor” according to EN 1264-4
Client: __________________________________________________________________________________________________
Building/ project: __________________________________________________________________________________________________
Stage of construction/
floor/dwelling: __________________________________________________________________________________________
Section of the system: __________________________________________________________________________________
Requirements
Before laying the screed, plaster or levelling compound, tightness of the heating/cooling circuits of the surface heating/coo-
ling system is tested by carrying out a water pressure test. Contrary to the VOB C (DIN 18 380 standard), the test pressuremust be at least for 4 bar and not more than 6 bar. This pressure must be maintained throughout the laying of the screed/
plaster*.
The test pressure is carried out section by section after having flushed the individual heating circuits. It must be ensured
that the succeeding sections of the system are protected from excess pressure (if necessary, by main isolation device in
front of the distributor/collector).
Alternatively, the tightness can also be tested by carrying out a pressure test with compressed air. Here, the maximum test
pressure amounts to 3 bar.
Documentation
Maximum permissible operating pressure _______________________________ bar
Test pressure _______________________________ bar
Test cycle _______________________________ h
Tightness was checked and no lasting deformation was detected on any component.
Confirmation
_______________________________ _______________________________ _______________________________
Place/date Place/date Place/date
_______________________________ _______________________________ _______________________________Builder/Client Building supervisor/Architect InstallerStamp/signature Stamp/signature Stamp/signature
*Procedure may be different for wall and ceiling heating systems.
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 55/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 56/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 57/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 58/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 59/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 60/108
...................................................................................................................... 96
................................................................................................................................................................... 96
................................................................................................................................................ 97
.................................................................................................................................... 98
....................................................................................................................................................................... 98
.................................................................................99 –100
................................................................................................................... 100
..................................................................................................................... 101
......................................................................................................................................... 102
............................................................................................................................................. 102
.................................................................................................................................................... 102
....................................................................................................................................................... 102
...................................................................................................................................................................... 102
......................................................................................................................................................................... 102
................................................................................................................ 103
..................................................................................................................................................................... 104
......................................................................................................... 105
........................................................................................................................................... 105
......................................................................................................................................... 105
.......................................................................................................... 106
........................................................................................................................................... 106
......................................................................................................................................... 106
......................................................................................................................................................... 107
60
Illustrated list – “Cofloor” surface heating and cooling systems –Extract from the catalogue 2013
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 61/10861
System illustration: “Unidis” Surface heating with return collector “Floorbox MH” and fixing channel
1 “Floorbox MH” Return collector
2 “Unibox EBV”
3 Fixing channel
4 “Copipe” Composition pipe
“Copex” PE-Xc pipe
“Copert” PE-RT pipe
System illustration: “Unidis” Surface heating with “Floorbox UH” and “Unibox EBV”
1 “Floorbox UH”
2 “Unibox EBV”
3 “Regumat F-130/180” Fixed value control unit
4 “Copipe” Composition pipe
“Copex” PE-Xc pipe“Copert” PE-RT pipe
1
2
34
2
Supply
“Unibox E BV” “Unibox E BV”
Return
Surface heating Surface heating
1
2
3
4
2
System summary
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 62/10862
System summary
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 63/10863
“Unidis” Surface heating systemwith local flow distribution
"Unibox EBV"
Combination room temperature control
and presettable bypass
Depth: 57 mm
Application:
For installations with flow temperatures
suitable for surface heating systems
according to DIN EN 1264.
Installation set consisting of:
Wall box unit with thermostatic valve with
integrated bypass stem and regulating insert,
working without auxiliary energy. Venting and
flushing valve, valve insulation and cover plate,
thermostat with '0' setting, valve connection
G ¾ for Oventrop compression fittings. For the
division of the flow rate into a permanent partial
flow adjustable via the bypass and a
thermostatically controlled partial flow. Setting
of a minimum flow rate via the bypass
guaranteeing a basic heat load of the
underfloor heating system (no cooling down).
0.75 0.28 0.52 102 26 62
I-57-I "Unibox RLA"
Combination isolating and regulating function
Installation set for the isolation of surface
heating circuits in combination with
"Uniboxes".
Page 2.18.
I-57-I "Unibox E T"
Room temperature control
Installation set consisting of:
Wall box unit with presettable thermostatic
valve, venting and flushing valve.
Page 2.18.
I-57-I "Unibox T"
Room temperature control
with thermostat "Uni LH"
Installation set consisting of:
Wall box unit with presettable thermostatic
valve, integrated deaeration and cover plate,
with thermostat "Uni LH".
Page 2.18.
"Unibox E BVC"
Combination room temperature control
with additional cooling position and presettable bypass
Installation set consisting of:
Wall box unit with thermostatic valve and
integrated bypass stem and regulating insert.
Page 2.21.
I-57-I "Unibox ETC"
Combinatioon room temperature control
with additional cooling function
Installation set consisting of:
Wall box unit with presettable thermostatic
valve, venting and flushing valve.
Page 2.21.
Article kvs
kv
at 1K
P-dev.
kv
at 2K
P-dev.
Article-No. Hint
Page 68
Page 68
Page 68
Page 70
Page 71
E TC"
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 64/10864
"Floorbox MH" Return collector
for "Unidis" surface heating
Central consolidation of heating circuit returns
in the "Unibox" system, lateral riser connection
The "Floorbox MH" is used for central
consolidation of the individual heating circuit
returns together with "Uniboxes".
(riser connection from the right and left hand
side)
Installation set consisting of:
Supply:
– Ball valve with temperature sensor
connection
– 2-fold distributor for the connection of two
supply pipes to the boxes
Return:
– Two return collectors (with flow measuring
and regulating inserts)
– Fill and drain cock
– Vent plug
– "Hycocon VTZ" double regulating and
commissioning valve
– Meter stool piece
– Ball valve
Models:
with one return collector (6-fold) 102 70 53
for 6 circuits
with two return collectors (4-fold each) 102 70 54
for 8 circuits
with two return collectors (5-fold each) 102 70 55
for 10 circuits
with two return collectors (6-fold each) 102 70 56
for 12 circuits
Article Article-No. Hint
"Floorbox U"
Connection without distributor/collector
for surface heating systems
The "Floorbox" serves to connect each
dwelling to the surface heating system together
with the installation sets "Unibox".
Installation set consisting of:
Supply:
- Ball valve G 1 with temperature sensor
connection
Return:
- "Hycocon VTZ" double regulating
and commissioning valve
- Meter stool piece
- Ball valve with coupling
- Venting and flushing valve
- Flat seals
Depth: 110 - 145 mm
Width: 400 mm
Height: 350 mm
System illustration: page 2.06
lateral connection
"Floorbox UH" lateral connection 102 26 68
lower connection
"Floorbox UV" lower connection 102 26 69
“Unidis” Surface heating systemwith local flow distribution
page 61
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 65/10865
Fixing channel For heavyweight and lightweight walls, made of
galvanised steel sheet for pipework installation
out of the ground into the wall to the "Unibox".
An additionally required installation set of the
"Unibox" range has to be ordered separately
and has to be installed in the fixing channel.
Assembly without screws or rivets. Adaptation
to the installation height via an adjustable
extension. The adaptation of the installation
depth for heavyweight walls is carried out by
use of elbows. The fixing channel of lightweight
walls is screwed directly onto the profiles.
Additional cut-outs in the reverse side of the
fixing channel allow the connection of the
"Unibox" even from an adjoining room.
The "Unibox" has to be mounted in the fixing
channel only shortly before plastering
commences.
An exact installation of the "Unibox" is
guaranteed by the variable installation options.
The connection openings (rated break points)
of the fixing channel allow the connection of all
remote controls, remote sensors (mechanical
or electric).
Height: 440 - 490 mm (extendible)
Width: 160 mm
for "Unibox", depth: 57 mm 102 26 53
Sequence of installation (summary):
1 Adjust depth and height, alignwith wall recess
2 Place fixing channel into the
wall
3 Mount “Unibox” and both
supply connection pieces
4 Mount protection cover of the
“Unibox” and of the fixing channel
5 Carry out wall plastering 6 Lay supply pipe from the heat
generator on the bare floor and
insulate
7 Lay edge isolating strip and
system board
8 Lay heating circuit, connect to
supply connection piece and feed
return to return collector
Article Article-No. Hint
“Unidis” Surface heating systemwith local flow distribution
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 66/10866
Fixing channel with isolating facility
with cover plate and thermostat with remote control
For heavyweight and lightweight walls, made of
galvanised steel sheet for pipework installation
out of the ground into the wall to the "Unibox".
An addtional installation set of the "Unibox"
programme has to be ordered separately and
has to be fit into the fixing channel.
For this purpose, the "Unibox E BV" is available
without cover plate (see item no. 102 26 76).
For the connection without distributors/
collectors and the room to room isolation of
surface heating circuits.
Isolating facility consisting of:
Isolating valve, venting and flushing valve,
valve connection G ¾ for Oventrop
compression fittings.
Assembly without screws or rivets. Adaptation
to the installation height via an adjustable
extension. The adaptation of the installation
depth for heavyweight walls is carried out by
use of elbows. The fixing channel of lightweight
walls is screwed directly onto the profiles.
Additional cut-outs in the reverse side of the
fixing channel allow the connection of the
"Unibox" even from an adjoining room.
The "Unibox" has to be mounted in the fixing
channel only shortly before plastering
commences. A special cover plate for the
"Unibox" is supplied with the fixing channel.
An exact installation of the "Unibox" isguaranteed by the variable installation options.
The connection openings (rated break points)
of the fixing channel allow the connection of all
remote controls, remote sensors (mechanical
or electric).
Height: 440 - 490 mm (extendible)
Width: 160 mm
for "Unibox", depth: 57 mm 102 26 54*
"Unibox E BV"
without cover plate and thermostat
Application:
For installations with flow temperatures
suitable for surface heating systems according
to DIN EN 1264.
Installation set for use in the fixing channel with
heating circuit isolation (item no. 102 26 54).
Installation set consisting of:
Wall box unit without cover plate, thermostatic
valve with integrated bypass stem and
regulating insert, working without auxiliary
energy. Venting and flushing valve, valve
insulation, valve connection G ¾ for Oventrop
compression fittings.
For the division of the flow rate into a
permanent partial flow adjustable via the
bypass and a thermostatically controlled partial
flow. Setting of a minimum flow via the bypass
guaranteeing a basic heat load of the
underfloor heating (no cooling down).
Combination room temperature control 102 26 76*and presettable bypass
Article Article-No. Hint
“Unidis” Surface heating systemwith local flow distribution
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 67/10867
Pipe connection press T-piece Height: 321 mm
Stainless steel pipe: Ø 15 x 1.0 mm
For a simple connection of the "Unibox" to the
supply pipe or the heating loop via the fixing
channel.
The pipes have to be shortened according to
the required installation height.
Pipe made of stainless steel, fitting made of brassfor composition pipe "Copipe",
with "Ofix CEP" - Snap & Seal -
compression fitting for male thread G ¾
according to DIN V 3838 (cone "Euro")
16 x 2.0 mm 151 51 53*20 x 2.5 mm 151 51 56*
Pipe connection press elbow
Pipe made of stainless steel, fitting made of brass
for composition pipe "Copipe",
with "Ofix CEP" - Snap & Seal -
compression fitting for male thread G ¾
according to DIN V 3838 (cone "Euro")
16 x 2.0 mm 151 53 53*20 x 2.5 mm 151 53 56*
Article Article-No. Hint
Heating circuit level
3
Heating
circuit level
Supply level S u p
p l y l e v e
l
H e a t i n
g
c i r c u i t l
e v e l
Heating circuit
level
Supply level
Heating circuit level
“Unidis” Surface heating systemwith local flow distribution
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 68/10868
"Unibox E BV"
Combination room temperature control
and presettable bypass
Depth: 57 mm
white model
"Unibox E" (exclusive model) and "Unibox"
individual room temperature control for
surface heating systems
Application:
For installations with flow temperatures
suitable for surface heating systems
according to DIN EN 1264.
Installation set consisting of:
Wall box unit with thermostatic valve with
integrated bypass stem and regulating insert,
working without auxiliary energy. Venting and
flushing valve, valve insulation and cover plate,
thermostat with '0' setting, valve connection
G ¾ for Oventrop compression fittings. For the
division of the flow rate into a permanent partial
flow adjustable via the bypass and a
thermostatically controlled partial flow. Setting
of a minimum flow via the bypass guaranteeinga basic heat load of the underfloor heating (no
cooling down).
0.75 0.28 0.52 102 26 62
"Unibox RLA"
Combination isolating and regulating function
Depth: 57 mm
Installation set consisting of:
Wall box unit with isolating valve, venting and
flushing valve, closed cover plate, valve
connection G ¾ for Oventrop compression
fittings. For the isolation of surface heating
circuits in combination with the installation sets
"Unibox".
white model 102 26 63
"Unibox E T"
Room temperature control
Depth: 57 mm
Installation set consisting of:
Wall box unit with presettable thermostatic
valve, venting and flushing valve, valve
insulation and cover plate, thermostat with '0'
setting, valve connection G ¾ for Oventrop
compression fittings.
For room temperature control.
Temperature range: 7 - 28 °C
(room temperature)
Model:
white 0.75 0.28 0.52 102 26 32
chrome
plated
0.75 0.28 0.52 102 26 42
"Unibox T"
Room temperature control
with thermostat "Uni LH"
Depth: 57 mm
Installation set consisting of:
Wall box unit with presettable thermostatic
valve, integrated deaeration and cover plate,
with thermostat "Uni LH" with '0' setting, valve
connection G ¾ for Oventrop compression
fittings.
For room temperature control.
Temperature range: 7 - 28 °C
(room temperature)
The models "Unibox ET" and "Unibox T"
comply with the requirements of the Energy
Saving Directive (EnEV § 14).
Model:
white 0.90 0.32 0.65 102 26 36
chrome
plated
0.90 0.32 0.65 102 26 46
Article kvs
kv
at 1K
P-dev.
kv
at 2K
P-dev.
Article-No. Hint
“Unibox” Room temperature control
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 69/10869
"Unibox TSH"
Room temperature control
with thermostat "Uni SH"
Depth: 57 mm
Installation set consisting of:
Wall box unit with presettable thermostatic
valve, integrated deaeration and cover plate,
with thermostat "Uni SH" with '0' setting, valve
connection G ¾ for Oventrop compression
fittings.
For room temperature control.
Temperature range: 7-28 °C
(room temperature)
The models "Unibox E T", "Unibox T" and
"Unibox TSH" comply with the requirements of
the Energy Saving Directive (EnEV § 14).
white model
0.32 0.59 0.80 102 26 12
Article kvs
kv
at 1K
P-dev.
kv
at 2K
P-dev.
Article-No. Hint
"Unibox E plus"
Combination room temperature control
and limitation of return temperature
Depth: 57 mm
"Unibox E" (exclusive model) individual
room temperature control and limitation of
return temperature for surface heating
systems
Application:
In combination with heating systems with
radiator operation.Installation set consisting of:
Wall box unit with presettable thermostatic
valve and integrated return temperature limiter,
venting and flushing valve, valve insulation and
cover plate, thermostat with '0' setting, valve
connection G ¾ for Oventrop compression
fittings.
For the control of the room temperature and
limitation of the return temperature.
Temperature range: 7-28 °C
(room temperature)
20-40 °C (return temperature)
Good Design Award Japan
Model:
white 0.75 0.28 0.52 102 26 33chrome
plated
0.75 0.28 0.52 102 26 43
stainless
steel finish
0.75 0.28 0.52 102 26 73
“Unibox” Room temperature control
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 70/10870
"Unibox E vario"
Basic model for limitation of
return temperature (hidden)Depth: 57 mm
Installation set consisting of:
Wall box unit with presettable thermostatic
valve and integrated return temperature limiter,venting and flushing valve and closed cover
plate, valve connection G ¾ for Oventrop
compression fittings.
For the control of the room temperature and
limitation of the return temperature.
Temperature range: 20-40 °C
(return temperature)
Room temperature depending on the used
control.
Model:
white 0.75 0.28 0.52 102 26 34
chrome
plated
0.75 0.28 0.52 102 26 44
Room temperature control is possible by mounting the following
thermostats (to be ordered separately):
– Thermostat with remote control "Uni FH"
(page 2.73)
and thermostat "Uni FHC" (page 1. 00 )
or:
– room thermostat and actuator
(page 3. 00 )
"Unibox E RTL"
Limitation of return temperature (hidden)
Depth: 57 mm
Installation set consisting of:
Wall box unit with integrated return
temperature limiter, venting and flushing valve
and closed cover plate, valve connection G ¾
for Oventrop compression fittings.
For return temperature limitation.
Temperature range: 20-40 °C
(return temperature).
The models- "Unibox E plus"
- "Unibox E vario"
comply with the requirements of the Energy
Saving Diretive (EnEV § 14).
white model 102 26 31
chrome plated model 102 26 41
Limitation of the return temperature from the outside:
page 2.22, item no. 102 26 35 / 45
"Unibox E BVC"
Combination room temperature control
with additional cooling position and presettable bypass
Depth: 57 mm
"Unibox E" (exclusive model) individual
room temperature control for surface
heating and cooling systems
Application:For installations with flow temperatures
suitable for surface heating systems
according to DIN EN 1264.
Installation set consisting of:
Wall box unit with thermostatic valve with
integrated bypass stem and regulating insert,
working without auxiliary energy. Venting and
flushing valve, valve insulation and cover plate,
thermostat with cooling position, valve
connection G ¾ for Oventrop compression
fittings. For the division of the flow rate into a
permanent partial flow adjustable via the
bypass and a thermostatically controlled partial
flow (only in case of heating). Setting of aminimum flow via the bypass guaranteeing a
perfect operation of heat pumps and for a
basic heat load of the underfloor heating (no
cooling down).Temperature range: 7-28 °C
(room temperature)
Additional cooling position: C (cooling
depending on the flow temperature).
white
model
0.75 0.28 0.52 102 26 67
“Unibox” Room temperature control
Article kvs
kv
at 1K
P-dev.
kv
at 2K
P-dev.
Article-No. Hint
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 71/10871
"Unibox E TC"
Combination room temperature control
with additional cooling positionDepth: 57 mm
Installation set consisting of:
Wall box unit with presettable thermostatic
valve, venting and flushing valve, valveinsulation and cover plate, thermostat with
cooling position, valve connection G ¾ for
Oventrop compression fittings.
For room temperature control.
Temperature range: 7-28 °C
(room temperature)
Additional cooling position: C (cooling
depending on the flow temperature).
white
model
0.75 0.28 0.52 102 26 66
Article kvs
kv
at 1K
P-dev.
kv
at 2K
P-dev.
Article-No. Hint
"Unibox plus"
Combination thermostat "Uni LH"
and thermostat "Uni RTLH"
Depth: 57 mm
„"Unibox" individual room temperature
control and limitation of return temperature
for surface heating systems.
Application:
In combination with heating systems with
radiator operation.
Installation set consisting of:
Wall box unit with presettable thermostatic
valve and RTLH valve, venting and flushing
valve and cover plate, thermostats "Uni LH"
and "Uni RTLH" with '0' setting. Valve
connection G ¾ for Oventrop compression
fittings.
The RTLH valve insert with double disc
prevents inadvertent overheating, with frostprotection.
For the control of the room temperature and
limitation of the return temperature.
Temperature range: 7–28 °C
(room temperature)
10–40 °C factory setting (return temperature)
may be increased to 50 °C by cancelling the
limitation (40 °C) .
Awards "Unibox Plus":
Interclima ParisTrophée du Design
Interclima ParisConcours de l’Innovation
Model:
white 0.90 0.65 102 26 37
chrome
plated
0.90 0.65 102 26 47
"Unibox vario"
Basic model for
limitation of return temperature
(with thermostat "Uni RTLH")
Depth: 57 mm
Installation set consisting of:
Wall box unit with presettable thermostatic
valve and RTLH valve, venting and flushing
valve and cover plate, thermostat "Uni RTLH"
with '0' setting, valve connection G ¾ for
Oventrop compression fittings.
The RTLH valve insert with double disc
prevents inadvertent overheating, with frost
protection.
For the control of the room temperature and
limitation of the return temperature.
Temperature range: 10–40 °C factory setting
(return temperature) may be increased to 50 °C
by cancelling the limitation (40 °C).
Room temperature depending on the used
control.
Model:
white 0.90 0.32 0.65 102 26 38
Room temperature control is possible by mounting the following
thermostats (to be ordered separately):
– Thermostat with remote control "Uni FH" (page 2.73)
and thermostat "Uni FHC" (page 1. 00 )
or
– room thermostat and actuator
(page 3. 00 ),When using an electromotive actuator, the stem extension, item no.
102 26 98, is required.
“Unibox” Room temperature control
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 72/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 73/10873
Conversion set "Unibox T" Position 1 - 4 are used for the conversion of a
"Unibox E RTL" to "Unibox T".
A "Unibox E RTL" can be re-assembled by use
of the valve dismounted before and positions
5 - 7.
5
4
3
2
1
o v e n t r o p
for "Unibox E RTL"102 26 39
consisting of:
1 Presettable thermostatic valve
2 Thermostat "Uni LH"
3 Spacer, screws
4 White cover plate
5 Wall box unit
6 Bracket
7 Protection cover plate
Accessories
Fixing channel
for "Unibox", depth: 57 mm 102 26 52 Made of galvanised sheet steel, with covermade of gypsum plaster board.
Height: extendible between 275 and 350 mm
Width: 130 mm
for "Unibox", depth: 57 mm 102 26 53 Made of galvanised steel sheet
Height: extendible between 400 and 490 mm
Width: 160 mm
Pipe conduit unit
for "Unibox", depth: 57 mm 102 26 50 Suitable for the wall box units.
For a simple installation of the pipe into thewall. May be easily reduced to other
dimensions.
L = 1 m.
Cover plates
white model (RAL 9016) 102 26 87 For "Unibox E BV", "Unibox E BVC", "Unibox E
plus", "Unibox E T" and "Unibox E TC" with
depth 57 mm.
chrome plated model 102 26 88
white model (RAL 9016)
closed 102 26 79 For "Unibox E vario" with depth 57 mm.
white model (RAL 9016) 102 26 89 For "Unibox E RTL" with depth 57 mm.
chrome plated model 102 26 90
white model (RAL 9016) 102 26 93 For "Unibox RTL", "Unibox T", "Unibox vario"
and "Unibox plus" wall box unit with depth 57
mm.
chrome plated model 102 26 94
white model (RAL 9016) (2) 102 26 91 For "Unibox RTL", "Unibox T" and "Unibox
plus" wall box unit with depth 110 mm.
chrome plated model 102 26 92
Cover plate with thermostat with remote control
chrome plated model 102 26 97
ArticlePacking
unit Article-No. Hint
“Unibox” Room temperature control
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 74/10874
Valve inserts
for return flow valves (100) 102 69 81 Valve insert with double disc.
Prevents inadvertent overheating,
with frost protection.
Special valve insert for reversed supply and return pipe
with 6 presetting positions
As replacement for:
– "Multiblock T/TF"
– "Unibox ET/ETC"
– "Unibox E plus"
– "Unibox E vario"
– "Unibox E BV/ E BVC"
In case of reversed direction of flow for:
– "Unibox T"
– "Unibox plus" (connection for room
temperature control)
– "Unibox vario (connection for room
temperature control)
0.52 (100) 118 70 77
"Series AV 6", "Series RFV 6" and "Series E" Also for "Hycocon ETZ".
0.65 (100) 118 70 57# #These valve inserts are suitable for all valve
bodies with connection thread M 30 x 1.5 of all
sizes of the "Series A, AV 6, ADV 6, AZ, E, F,
RF and RFV 6".
Valve insert RTLH (100) 102 69 70 Special valve insert for reversed supply and
return pipe for "Unibox RTL".
Extensions
L = 20 mm
for thermostatic valves (10) 102 26 98 For "Unibox T" and "Unibox plus".
for RTLH valves (10) 102 26 99 For "Unibox RTL" and "Unibox vario".
Gland nut
Set = 5 pieces (10) 102 69 86
Duo connection piece
For the connection of two heating circuits.1 x G ¾ collar nut 2 x G ¾ male thread 102 26 55
Article
kv
at 2K
P-dev.
Packing
unit Article-No. Hint
“Unibox” Room temperature control
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 75/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 76/10876
"Cofloor" Base mat system NP-R
Pre-punched base mat without
thermal insulation with foil overlap on both sides,
for fixing 12 mm pipes
offering the possibility of 45° diagonal laying
without auxiliary material,
laying distances 5, 10, 15 cm
The perforation of the base mats allows a
simple application and a safe bonding of the
levelling compound and the existing ground.
Tested minimum construction heights:
-Knauf levelling compound Alphadur 430
min. 17 mm
-PCI periplan min. 18 mm
-Weber-Maxit weber.floor min. 18 mm
-Knauf levelling screed min. 21 mm
Further products on request!
The laying advice must be observed.
Base mat NP-R
1.0 x 1.0 m = 1.0 m²
without thermal insulation
made of moulded polystyrene foil,with adhesive layer on reverse
Only sold in units of 10 base mats per box.
(10) 140 20 10
Edge isolating strip
with adhesive edge
and integrated fleece back
height: 50 mm, thickness: 5 mm
Only sold in units of 12 rolls per bag.
length per roll 25 m (12) 140 19 90
PE-RT "Copert" Plastic pipe
with oxygen barrier
in rolls
Dimension 12 x 2.0 mm
Application:
Surface heating and cooling.
Pipes according toDIN 16833 / DIN 16834 / DIN 4721.
Oxygen tight according to DIN 4726.
Max. operating pressure ps: 6 bar at 70 °C
length per roll 200 m (200) 140 19 52
Duo connection piece
For the connection of two heating circuits.1 x G ¾ collar nut 2 x G ¾ male thread 102 26 55
"Ofix K" compression fittings
“Ofix K” for plastic pipes according to DIN 4726, PE-X according to
DIN 16892/16893, PB according to DIN 16968, PP according to DIN
8078 A1, collar nut unplated, metal to metal sealing plus O-ring
12 x 2 mm (10) 102 77 72
ArticlePacking
unit Article-No. Hint
“Cofloor” Systems“Copex”, “Copipe” and “Copert” pipes and accessories
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 77/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 78/10878
Tape gun
for tapes
For bonding the linings of the base mat roll
breadths or insulation boards.
with a width of 50 mm 140 25 98
Adhesive tape For bonding the linings of the base mat roll
breadths or insulation boards to prevent
penetration of screed water.50 mm x 66 m (36) 140 25 99
"Cofloor" Clamping rail system
Self-adhesive clamping rail made of polypropylene,
clamping distance 5 cm, length 1 m
For fixing the heating pipes onto the insulation.
for 14 mm pipe (100) 140 25 80
for 16 mm pipe (100) 140 25 81
ArticlePacking
unit Article-No. Hint
“Cofloor” Systems“Copex”, “Copipe” and “Copert” pipes and accessories
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 79/10879
"Cofloor" Dry-build system
for fixing 14 mm pipes,
laying distances 12,5 cm, 25 cm
For laying of surface heating systems on solid
or timber beam floors as a dry-build system
(reduced overall thickness, for instance
renovation of existing buildings) or with heating
screed according to DIN 18560 on a
membrane made of polystyrene.
Taking certain installation conditions into
consideration, the dry-build system is also
suitable for wall heating and cooling systems.
Dry-build element
1000 x 500 x 25 mm
made of expanded polystyrene according to DIN EN 13163,
thermal conductivity group 035,
building material class B1 according to DIN 4102
Element for serpentine or spiral laying of the
heat conducting strips and elbows. For
"Copipe HSC" composition pipe 14 x 2 mm.
Only sold in units of 10 boards wrapped up in a
plastic foil.
Thermal resistivity: R = 0.5 (m²K)/W.Max. load: 60 kN/m² (10) 140 28 00
Heat conducting strip
998 x 22 x 0.4 mm
made of galvanised sheet steel
For laying "Copipe HSC" composition pipe 14
x 2 mm and for improvement of the heat
transmission by a largesurface covering of the
dry-build elements.
Only sold in units of 48 strips per box.
with pre-punched break points
in the grooves
(48) 140 28 50
Heat conducting elbow
110 x 245 x 0.5 mm
For serpentine laying of the "Copipe HSC"
composition pipe 14 x 2 mm in the edge areas.
Only sold in units of 25 elbows per box.made of galvanised sheet steel (25) 140 28 55
Infill panel
1000 x 500 x 25 mm
made of expanded polystyrene according to DIN EN 13163,
thermal conductivity group 035, max. load 60 kN/m²,
building material class B1 according to DIN 4102
Only sold in units of 19 panels wrapped up in a
plastic foil.
(19) 140 28 57
Membrane
made of polyethylene 0.2 mm
As separation layer between dry-build system
and concrete or liquid screed.
Dimensions of roll 25 m x 4 m 140 28 95
Manual tool for cutting individual pipe ductsinto the infill panel.Hot cutting machine 140 28 91
ArticlePacking
unit Article-No. Hint
“Cofloor” Systems“Copex”, “Copipe” and “Copert” pipes and accessories
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 80/10880
Accessories
Edge isolating strip
with bonded foil and perforation,
height: 150 mm, thickness: 10 mm,
made of polyethylene foam
Suitable for concrete and liquid screed
complying with DIN EN 1264-4/ DIN 18560 T2.
Only sold in units of 8 rolls per bag.
length per roll 25 m (8) 140 20 90
Edge isolating strip
with adhesive strip, bonded foil
and perforation,
height: 120 mm, thickness: 10 mm
made of polyethylene foam
length per roll 50 m (10) 140 21 90
Expansion stripwith adhesive edge,
height: 120 mm, thickness: 10 mm,
made of polyethylene foam
To provide screed joints according to DIN EN1264-4 / DIN 18560 T2.
length: 1.20 m (20) 140 20 91
Protection pipe
made of LDPE
For protecting the pipe
- at junction points of screed joints
according to DIN EN 1264-4 /
DIN 18560 T 2
- at the entry points when set in concrete
- at the exit points when set in concrete
Only sold in units of 20 protection pipes
per bag.
Length: 300 mm, slit, (20) 150 11 84
for 14, 16 and 17 mm pipes
Round profile
made of polystyrene foam Ø 20 mm
Only sold in units = 1 dispenser.
Dispenser of 150 m 140 20 92
Pipe guiding elbow
plastic
for 14, 16 and 17 mm pipes
For the inversion and fixing of the PE-X pipes
in case of 90 ° bends, for instance in front of
the distributor/collector and in screed
passages.Set = 10 pieces 140 90 85
Marker point for measuring screed humidity
plastic
To mark the points of measurement of humidity
of the screed.
Set = 5 pieces 140 90 90
Calculation software
for the design of surface heating systems 140 99 99
Screed additive
Additional component
to produce concrete screed
for heated underfloor constructions
For homogenization and improvement of the
workability as well as for increase of the
concrete screed density.
Content of canister 10 l 140 90 95
ArticlePacking
unit Article-No. Hint
“Cofloor” Systems“Copex”, “Copipe” and “Copert” pipes and accessories
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 81/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 82/10882
“Cofloor” Systems“Copex”, “Copipe” and “Copert” pipes and accessories
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 83/10883
"Ofix K" Compression fittings
for G ¾
For the connection of the "Copex" PE-X pipes
and the "Copert" PE-RT pipes to the
distributor/collector and for couplings.
“Ofix K” for plastic pipes according to DIN 4726, PE-X according to
DIN 16892/16893, PB according to DIN 16968, PP according to DIN
8078 A1, collar nut nickel plated, metal to metal sealing plus O-ring
14 x 2 mm (10) 102 77 55
16 x 2 mm (10) 102 77 57
17 x 2 mm (10) 102 77 59
20 x 2 mm (10) 102 77 63
“Ofix K” for plastic pipes according to DIN 4726, PE-X according to
DIN 16892/16893, PB according to DIN 16968, PP according to DIN
8078 A1, collar nut unplated, metal to metal sealing plus O-ring
14 x 2 mm (10) 102 77 75
16 x 2 mm (10) 102 77 7717 x 2 mm (10) 102 77 79
20 x 2 mm (10) 102 77 83
"Cofit S" Compression fittings
for G ¾ male thread according to DIN V 3838 (cone "Euro"),
for "Copipe HSC" composition pipes and, provided similar
preparation is used, for plastic pipes,
metal to metal sealing plus O-ring,
outlet made of brass resistant to dezincification,
compression ring and collar nut made of brass
For the connection of the pipes to the
distributor/collector and for couplings.
(Interior of plastic pipes must be deburred.)
Collar nut nickel plated
14 x 2.0 mm x G ¾ c/nut (10) 150 79 5416 x 2.0 mm x G ¾ c/nut (10) 150 79 55
17 x 2.0 mm x G ¾ c/nut (10) 150 79 59
Collar nut unplated
14 x 2.0 mm x G ¾ c/nut (10) 150 79 74
16 x 2.0 mm x G ¾ c/nut (10) 150 79 75
ArticlePacking
unit Article-No. Hint
“Cofloor” Systems“Copex”, “Copipe” and “Copert” pipes and accessories
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 84/10884
"Cofit S" Compression fittings
for G ¾ male thread according to DIN V 3838 (cone "Euro"),
for "Copipe HSC" composition pipes and, provided similar
preparation is used, for plastic pipes,
2-fold, metal to metal sealing plus O-ring,
outlet made of brass resistant to dezincification,
compression ring and collar nut made of brass,
collar nut nickel plated
14 x 2.0 mm x G ¾ collar nut (10) 150 79 34
16 x 2.0 mm x G ¾ collar nut (10) 150 79 35
17 x 2.0 mm x G ¾ collar nut (10) 150 79 37
18 x 2.0 mm x G ¾ collar nut (10) 150 79 38
20 x 2.0 mm x G ¾ collar nut (10) 150 79 39
20 x 2.5 mm x G ¾ collar nut (10) 150 79 40
Double nipples
Double nipple, brass, nickel plated Port G ¾ with tapered sealing according to DIN
V 3838.G ¾ male x G ¾ male (10) 102 82 63
Double nipple, bronze, unplated
G ¾ M (25) 150 40 54
"Cofit P" Press couplings
for "Copipe HSC" composition pipes and, provided
similar preparation is used, for plastic pipes,
bronze, size 14 and 17 mm made of brass resistant
to dezincification, casing made of stainless steel
(Interior of plastic pipes must be deburred.)
Press coupling
14 x 14 mm (10) 151 25 42
16 x 16 mm (10) 151 25 43
17 x 17 mm (10) 151 25 44
ArticlePacking
unit Article-No. Hint
“Cofloor” Systems“Copex”, “Copipe” and “Copert” pipes and accessories
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 85/10885
“Multidis SF/SFB/SFI” Distributors/collectorsfor surface heating and cooling systems
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 86/10886
"Multidis SFI" Brass distributor/collector for industrial surface
heating and cooling systems
flat sealing distributor modules, flow distributor with
ball valves and return collector with regulating valves,
extension to max. 20 circuits by connecting the distributor
modules
Application:
Central heating systems with circulation pump.
Max. operating pressure ps: 6 bar (PN 6)
Max. operating temperature ts: 90 °C
Description:
Pre-assembled distributor modules, one port
G 2 male thread, one port G 2 collar nut, with
G ½ blind plug.
Flow distributor with ball valves. Return
collector with regulating valves.
Heating circuit connections with G 1 male
thread for Oventrop compression fittings.
for 2 circuits 141 44 52
for 3 circuits 141 44 53
for 4 circuits 141 44 54
for 5 circuits 141 44 55
for 6 circuits 141 44 56
Accessories
Console Consoles with 2 pipe clamps each including
sound insulation supports and quick acting
lock.
Wall attachment included.
for "Multidis SFI" brass 141 44 90
distributor/collector
2-fold, steel galvanised,
adjustable height and depth
Cap G 2 female thread
for "Multidis SFI" brass distributor/
collector, 2-fold, brass
141 44 93 For closing the distributor/collector.
Ball valve
flat sealing
DN 50 G 2 F x G 2 M 140 65 86 For isolation of the flow distributors and return
collectors.
"Optiflex" Ball valve
brass, handle with stop
For filling and venting.
self sealing, with coutnernut,
with hose connection (soft seal)
and cap
DN 15 (50) 103 33 14
"Cofit S" Compression fittings
for "Copex" PE-Xc plastic pipes,
2-fold, metal to metal sealing plus O-ring,
outlet bronze / brass resistant to dezincification,
brass compression ring,
brass collar nut, unplated
For the connection of the "Copex" PE-Xc
plastic pipes to the distributor as well as for
couplings.
20 x 3.0 mm x G 1 collar nut (10) 150 79 69
26 x 3.0 mm x G 1 collar nut (10) 150 79 79
ArticlePacking
unit Article-No. Hint
“Multidis SF/SFB/SFI” Distributors/collectorsfor surface heating and cooling systems
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 87/10887
Valve insert
for stainless steel distributors/ collectors "Multidis SF" (25) 140 40 91
Ball valves
flat sealing
DN 20 G ¾ F x G 1 M (10) 140 63 83
DN 25 G 1 F x G 1 M (10) 140 63 84
flat sealing, with thermometer (0–80°C)
with red T-handle
DN 20 G ¾ F x G 1 M 140 64 83
DN 25 G 1 F x G 1 M 140 64 84
flat sealing, with thermometer (0–80°C)
with blue T-handle
DN 20 G ¾ F x G 1 M 140 65 83
DN 25 G 1 F x G 1 M 140 65 84
flat sealing,
with sensor connection M 10 x 1.0
DN 25 G 1 F x G 1 M (10) 140 67 08
Ball valve
for "Multidis SF/SFB" stainless steel distributor/collector
with cone "Euro" Ball valve for the isolation of the heating
circuits at the distributor/collector. Heating
circuit connection G ¾ male thread for
Oventrop compression fittings. Distributor/
collector connection with collar nut G ¾ and
O-ring seal.
G ¾ male x G ¾ collar nut (50) 140 65 04
ArticlePacking
unit Article-No. Hint
“Multidis SF/SFB/SFI” Distributors/collectorsfor surface heating and cooling systems
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 88/10888
Cabinets
steel, galvanised, frame and doors white lacquered
removable screen
Depth: 115 – 180 mm
Height: 760 – 885 mm
When using heat meter connection sets, the
sum of the installation length and the length of
the distributor have to be taken into
consideration.
Outlet Length (L) No.°° Length with No.°°ball valves
140 63 842 190 mm 1 270 mm 13 240 mm 1 320 mm 14 290 mm 1 370 mm 15 340 mm 1 420 mm 16 390 mm 1 470 mm 17 440 mm 1 520 mm 28 490 mm 2 570 mm 29 540 mm 2 620 mm 210 590 mm 2 670 mm 311 640 mm 3 720 mm 312 690 mm 3 770 mm 3
°°No. of cabinets
no. 1: inner width: 560 mm 140 11 51
no. 2: inner width: 700 mm 140 11 52
no. 3: inner width: 900 mm 140 11 53
no. 4: inner width: 1200 mm 140 11 54
Surface-mounted cabinetssteel, galvanised, frame and doors white lacquered
Depth: 160 mmHeight: 760 – 870 mm
When using heat meter connection sets, the
sum of the installation length and the length of
the distributor have to be taken into
consideration.
no. 1: inner width: 600 mm 140 11 71
no. 2: inner width: 750 mm 140 11 72
no. 3: inner width: 1000 mm 140 11 73
no. 4: inner width: 1250 mm 140 11 74
Cylinder lock
with key
for surface-mounted cabinets 140 11 90 Only suitable for surface-mounted cabinets as
from November 2011.(140 11 71 - 74)
for cabinets 140 11 91
(140 11 51 - 54)
Article Article-No. Hint
“Multidis SF/SFB/SFI” Distributors/collectorsfor surface heating and cooling systems
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 89/10889
Heat meter connection sets
for "Multidis SF/SFB" stainless steel distributors/collectors for surface
heating and cooling systems as well as for "Multidis SH" stainless steel
distributors/collectors for radiator connection
Heat meter connection sets are suitable for left
and right hand side connection to the
distributor/collector.
Set no. 1 consists of:
Supply
- Ball valve with temperature sensor
connection
Return
– Double regulating and commissioning valve
"Hycocon VTZ"
– Meter stool piece
– Ball valve with coupling
– Flat seals
Illustr. example:
Set no. 1 angle pattern
Set no. 1
with double regulating and commissioning valve
“Hycocon VTZ”
Angle pattern:
with ball valves DN 20 140 45 78
with ball valves DN 25 140 45 80
Straight pattern:
with ball valves DN 20 140 45 79
with ball valves DN 25 140 45 81
Illustr. example:
Set no. 2 angle pattern
Set no. 2
with differential pressure regulator “Hycocon DTZ”
Angle pattern:
Set no. 2 consists of:
Supply
– Ball valve with temperature sensor
connection
– Measuring adapter
Return
– Differential pressure regulator
“Hycocon DTZ”
– Capillary
– Meter stool piece
– Ball valve
– Flat seals
with ball valves DN 25 140 46 80
Straight pattern:
with ball valves DN 25 140 46 81
Set no. 3
with pressure independent control valve „Cocon QTZ“
Angle pattern:
Set no. 3 consists of:
Supply
- Ball valve with temperature sensor
connection
Return
- Pressure independent control valve
"Cocon QTZ" (control range 150 - 1050 l/h)
- Meter stool piece
- Ball valve
- Flat seals
with ball valves DN 25 140 48 80
Straight pattern:
with ball valves DN 25 140 48 81
Article Article-No. Hint
“Multidis SF/SFB/SFI” Distributors/collectorsfor surface heating and cooling systems
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 90/10890
Differential pressure relief device
for "Multidis SF/SFB" stainless steel distributors/collectors
Differential pressure relief device for the right
hand side connection to the distributor/
collector.
To avoid flow noises.
Control range: 50-400 mbar
G ¾ male thread 140 47 90
Angle pattern connection set Angle pattern connection set for a bottom
connection to the distributor/collector when
using surface-mounted cabinets.for "Multidis SF/SFB" stainless steel distributors/collectors for surface
heating and cooling systems as well as for "Multidis SH" stainless steel
distributors/collectors for radiator connection
140 47 80
"Hycocon VTZ" Double regulating and commissioning valve
with infinitely adjustable presetting
"eco" measuring technique
both ports with integrated pressure test points and drain valves
"eco" measuring technique:
Information: page 3. 00 .
Operating temperature:
-10 °C up to +120 °C
General information:
Body and bonnet made of brass resistant to
dezincification.
Male thread G 1.
both ports male thread, flat sealing
DN 20 2.70 (10) 106 18 56
"Hycocon DTZ" Differential pressure regulator
nominal value: 50 to 300 mbar, infinitely adjustable
"eco" measuring technique
with integrated pressure test point and drain valve
"eco" measuring technique:
Information: page 3. 00 .
Operating temperature:
-10 °C up to +120 °C
General information:
Body and bonnet made of brass resistant to
dezincification.Male thread G 1.
both ports male thread without collar nut
DN 20 2.70 106 21 56
Article kvsPacking
unit Article-No. Hint
“Multidis SF/SFB/SFI” Distributors/collectorsfor surface heating and cooling systems
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 91/10891
"Regufloor H"
"Control unit DN 25 Heating
for connection to the stainless steel distributor/collector
Application ("Regufloor H and HW"):
Fixed value control unit for connection to
the stainless steel distributor/collector for
surface heating systems.Connection of 2 - 12 heating circuits.
Length: 315 mm
Depth: 145 mm
Pump length: 130 mm
Max. operating pressure: 6 bar
Max. differential pressure: 0,75 bar
Max. flow temperature:
Primary side: 90 °C
Secondary side: 50 °C
Control range:
("Regufloor H" only): 20–50 °C
Electric sensor attached to pipe
Temperature range: 20–90 °C
Description ("Regufloor H"):
Pre-assembled and tested fixed value control
unit with electronic pump, three-way diverting
valve, check valve, temperature controller with
contact sensor. Electric pipe contact safety
switch for max. limitation of the flow
temperature.
Description ("Regufloor HW"):
As "Regufloor H" but three-way diverting valve
with electromotive actuator (three point),
heating circuit controller with outdoor sensor
and flow temperature sensor.
with high-efficiency pump 115 13 00
Wilo Yonos Para
(Energy Efficiency Index EEI ≤ 0.23
according to EC Regulation 641/2009)
with Wilo pump E15/ 1-5 115 10 00
(export model, only for sales outside
the European Union)
"Regufloor HW"
Control unit DN 25 Heating
as above, but with
weather guided control for connection
to the stainless steel distributor/collector
with high-efficiency pump 115 18 00*Wilo Yonos Para and
heating circuit controller "Regtronic RH-B"
(Energy Efficiency Index EEI ≤ 0.23
according to EC Regulation 641/2009)
with Wilo pump E15/1-5 and 115 15 00
heating circuit controller "Regtronic EH"
(export model, only for sales outisde
the European Union)
System components For the isolation of the supply and return,
use Oventrop ball valves
item no. 140 63 83 DN 20 and
item no. 140 63 84 DN 25.
T-connection piece 115 10 80 With check valve and sensor point.
Three-way diverting valve
with S-connection fitting 115 10 81
Temperature controller Control range 20–50 °C.
Only supplied as replacement.with contact sensor 115 10 82
Pump without pump cable.
Only supplied as replacement.WILO E15/1-5 115 10 86
(export model, only for sales
outside the Europan Union)
Article Article-No. Hint
“Regufloor” Control units
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 92/10892
Pump without pump cable. Only supplied as
replacement.High-efficiency pump 115 10 88*Wilo Yonos Para
(Energy Efficiency Index EEI ≤ 0.23according to EC Regulation 641/2009)
Including cabling for Wilo pump E15/1-5.Electric pipe contact safety switch 115 10 87
Bracket
T-connection piece 115 10 85
Article Article-No. Hint
"Regtronic EH" Heating circuit controller Weather-guided control of the flow
temperature of the heating system by
activation of a heat generator and/or a mixing
valve.with 1 outdoor sensor and 3 further sensors (NTC 5000)
230 V 115 20 92°
“Regufloor” Control units
"Regtronic RH-B" Heating circuit controller Weather guided flow temperature control of the
heating system via the demand of a heat
generator and/or a mixing valve (e.g. "Regumat
M3" or "Regufloor HW" with three-way mixing
valve). Controller for wall attachment with data
bus (S-bus).
Basic functions: 1 variable and 1 constant
temperature circuit with heat demand.Extendable by "Regtronic EM-B". The status
can be viewed via a full graphic display.
Interfaces: S-bus, SD-card slot for data
recording
Inputs: 8 sensor inputs (PT 1000, KTY, switch
or remote control), inputs for electronic volume
flow sensor/pressure sensor and irradation
sensor
Outputs: 4 solid-state relays (speed controlled),
1 standard relay (volt free), 2 PWM outputs for
the speed controlled activation of high-
efficiency pumps. Both PWM outputs can be
switched to 0-10 V.
with 1 outdoor sensor 115 20 93
and 3 further sensor (PT 1000)
Accessories
Room temperature sensor 115 20 95 Room temperature sensor for fixing on level
surfaces (surface mounting).PT 1000
Remote control with room temperature sensor
PT 1000 for the connection to the heating
circuit controller "Regtronic RH-B" for acomfortable control of the heating curve of the
controller from the living area. When increasing
the heating curve, the flow temperature is
increased and vice versa. The remote control
also features the functions "heating circuit off"
and "party position".
Remote control with
room temperature sensor
115 20 96
PT 1000
"Regtronic EM-B" Extension module "Regtronic EM-B" for the extension of the
heating circuit controller "Regtronic RH-B" by 6sensor inputs and 5 relay outputs.
This allows the activation of further variable
and constant temperature circuits.
Up to five extension modules can be
connected to the heating circuit controller
"Regtronic RH-B".
1 sensor attached to pipe PT 1000 is included.
for the connection to the heating circuit 115 20 98
controller "Regtronic RH-B"
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 93/10893
"Regufloor HC"
Control unit DN 25 Heating/Cooling
for connection to the stainless steel distributor/collector
Application:
Control unit for flow temperature control of
surface heating systems or alternatively of
surface cooling systems in conjunction with the
Oventrop stainless steel distributors/collectors.
Pre-assembled and tested control unit with
electronic pump and three-way diverting valve.
Suitable for the connection of 2 - 12 heating
circuits to two, three and four pipe systems
Heating and Cooling.
Length: 315 mm
Max. operating pressure: 6 bar
Max. differential pressure: 0.75 bar
Max. flow temperature:
Primary side: 90 °C
Secondary side: 50 °C
with high-efficiency pump 115 21 00*Wilo Yonos Para
(Energy Efficiency Index EEI ≤ 0.23
according to EC Regulation 641/2009)
with Wilo pump E15/1-5 115 20 00
(export model only for sales outside
the European Union)
System components for "Regufloor HC"
Flow temperature control set:
Climate controller heating/cooling
Memory stick
Electrothermal actuator
Outdoor sensor
Flow temperature sensor
Room humidity measuring transducer
Electric sensor attached to pipe
Electromotive actuatorMains adaptor
The flow temperature control set for outside
temperature guided surface heating and
cooling systems enables an automatic
changeover from heating to cooling. By
calculating the dew point, condensation is
prevented by an automatic adjustment of the
flow temtemperature. The control includes
heating and cooling curve, changeover for the
individual room temperature controls as well astimed programmes.
115 20 20
Optional accessory for the remote control of
the climate controller heating/cooling.Remote control for the climate 115 20 25
controller heating/cooling
Connection system for
room thermostats and actuators
Connection system for installation into the
distributor/collector cabinet with 6 channels for
the connection of the room thermostats and
actuators. Several connection systems can be
installed in parallel. The connection system andthe flow temperature concontrol set are co-
ordinated.
230 V 115 20 45
Room thermostat for individual room
temperature control. Adjustment of the nominal
temperature value, absence or presence. Entry
for operating mode changeover from heating or
cooling.
Room thermostat 115 20 63
heating/cooling 230 V
Article Article-No. Hint
“Regufloor” Control units
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 94/10894
"Aktor T 2P" Electrothermal actuators (two point)
connection thread M 30 x 1.5
Oventrop electrothermal actuators are used for
heating, ventilation and air-conditioning. The
actuators serve to control the room
temperature and can be used e. g. with
conventional radiators, radiators with
integrated distributor, distributors for surface
heating, radiant ceiling panels, chilled ceiling
systems and induction air systems in
combination with two point room thermostats.
Further applications in bivalent heating
installations.
For zone and room temperature control.
Connecting cable 1 m.
With First-Open function (except for actuators
"opened with current off") and stroke index.
Simple plug-in connection with valve adapter.
Actuators can be installed in any position.
As for the model with auxiliary switch, a pump
can e. g. be switched via the integrated volt
free contact. Due to their construction, the
electrothermal actuators are secured against
overvoltage which could occur when switching
on neon tubes. A varistor is thus not necessary.
"H NC", closed with current "off", 230 V 101 28 15"L NC, closed with current "off", 24 V 101 28 16
Dew point control 24 V "Sensos GA FD" Is required in combination with room
thermostats to protect chilled ceilings against
condensation.
An actuator interrupting the cooling water flow
is for instance activated in conjunction with the
"Regufloor HC".
Connection to the cooling water supply.
Connecting cable 1 m.
with alternating contact 114 19 51
System components
Controller for universal application in air
conditioning and heating systems, for instance
for flow temperature control in surface heating
and cooling systems. With integrated
measuring, control and timed function via two
PI controllers and preset parameters for an
easy initial operation.
Controller heating/cooling 115 30 41
Including cabling for Wilo pump E15/1-5.Electric pipe contact safety switch 115 10 87
Optional plug-in memory for controller heating/
cooling for documentation and copying of
parameter settings.
Memory for controller heating/cooling 115 30 42
Article Article-No. Hint
“Regufloor” Control units
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 95/108
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 96/10896
"Regufloor HX"
Control unit DN 25 Heating
for connection to the stainless steel distributor/collector.
For flow temperature control of
surface heating systems, with heat exchanger.
Application:
Fixed value control unit for the operation
of open vented surface heating systems in
heating systems (separate circuits).
Installation on the left hand side of the
distributor/collector.
Connection of 2-12 heating circuits.
Max. operating pressure:
Primary side: 6 bar
Secondary side: 3 bar
Max. flow temperature:
Primary side: 90 °C
Secondary side: 50 °C
Control range: 20–50 °C
Description:
Pre-assembled and tested fixed value control
unit with electronic pump (plastic body).
Heat exchanger, diaphragm expansion tank
(3 l), pressure gauge, safety valve.
with high-efficiency pump 115 10 65*Wilo Yonos Para
(Energy Efficiency Index EEI ≤ 0.23
according to EC Regulation 641/2009)
with Wilo pump E15/1-5 115 10 60
(export model, only for salesoutside the European Union)
"Tri-D TR" Three-way diverting valves PN 16
bronze
connection thread M 30 x 1,5
with collar nuts, flat sealing
Application:
Max. operating pressure ps: 16 bar (PN 16)Operating temperature ts: 0 °C up to 120 °C
Diverting, mixing or changing-over of flow
volumes in heating and cooling systems in
combination with thermostatic or electric
actuators.OV
I II
III
DN 20 4.50 113 02 06
DN 25 6.50 113 02 08
DN 40 9.50 113 02 12
"Tri-M TR" Three-way mixing valves PN 16
bronze
connection thread M 30 x 1,5with collar nuts, flat sealing
Male thread:
G 1
G 1 ¼
G 2
B
AAB
OV
DN 20 4.50 113 17 06
DN 25 6.50 113 17 08
DN 40 9.50 113 17 12
“Regufloor” Control units
Article kvs Article-No. Hint
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 97/10897
Room thermostats, clocks
Electronic room thermostat-surface mountingfor steady control (0 - 10 V) The electronic room thermostat is required forindividual room temperature control in
conjunction with the electrothermal actuator
(0- 10 V), item no. 101 29 52, page 1. 00 ,
or the electromotive actuator, item no.
101 27 05/06, page 1. 00 (may also be used
in three or four pipe systems).
With one analogue output 0–10 V each for
heating and cooling as well as adjustable
neutral zone (0.5–7.5 K).
Temperature range: 5 °C up to 30 °C
24 V 115 21 51
Room thermostat-clock - surface mounting
with daily setting
The electric room thermostat-clock is required
for individual room temperature control ofheating systems in conjunction with the
electrothermal actuators (two point). Output
signal pulse-width modulation.
Temperature range: 5 °C up to 30 °C
Heating:
Use electrothermal actuators (two point)
“closed with current off”.
Central temperature setback is carried out
according to a timed programme.
Limitation of the control range by using the
hidden limiting elements.
230 V 115 25 51
with weekly setting
230 V 115 25 52
24 V 115 25 54
Protection cover
for room thermostat-clock 230 V 115 25 91
Room thermostat - surface mounting The surface- or flush-mounted model of the
electric thermostat is required for individual
room temperature control in conjunction with
the electrothermal actuators (two point).
Temperature range: 5 °C up to 30 °C
Heating: Use electrothermal actuators (two
point) “closed with current off”. As for item no.
115 20 51/52/71/72, temperature may be set
back by use of an external time switch (item
no. 115 25 51/52 for 230 V, item no. 115 25 54
for 24 V).
Cooling: Use electrothermal actuators (two
point) “opened with current off”.
Limitation of the control range of item no.
115 20 51/52/ 71/72 by using the hidden
limiting elements.
230 V 115 20 51
24 V 115 20 52
Article Article-No. Hint
Room thermostats, actuators, wireless controls
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 98/10898
Article Article-No. Hint
Room thermostats, actuators, wireless controls
"Aktor T" Electrothermal actuators
"Aktor T 2P" Electrothermal actuators (two point)connection thread M 30 x 1.5
Oventrop electrothermal actuators are used forheating, ventilation and air-conditioning. The
actuators serve to control the room
temperature and can be used e. g. with
conventional radiators, radiators with
integrated distributor, distributors for surface
heating, radiant ceiling panels, chilled ceiling
systems and induction air systems in
combination with two point room thermostats.
Further applications in bivalent heating
installations.
For zone and room temperature control.
Connecting cable 1 m.
With First-Open function (except for actuators
"opened with current off") and stroke index.
Simple plug-in connection with valve adapter.
Actuators can be installed in any position. As for the model with auxiliary switch, a pump
can e. g. be switched via the integrated volt
free contact. Due to their construction, the
electrothermal actuators are secured against
overvoltage which could occur when switching
on neon tubes. A varistor is thus not necessary.
"H NC", closed with current "off", 230 V 101 28 15
"L NC, closed with current "off", 24 V 101 28 16
Accessories
Connecting block (6 control zones)
for room thermostats and and actuators 140 10 80
Connecting block (8 control zones)
for room thermostats and actuators 140 10 81
Suitable for connecting blocks 140 10 80 and
140 10 81 to switch off the pump when all
valves are closed.
Pump logic 24 V 140 10 85
Pump logic 230 V 140 10 86
Room thermostat - flush mounting
230 V 115 20 71
24 V 115 20 72
Room thermostat - flush mounting
digital
With LCD display and adjustable timed
programme.
Temperature range: 5 °C up to 35 °C230 V 115 25 61
24 V 115 25 62
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 99/10899
Room thermostats with wireless transmitter, wireless receiver The room thermostat with wireless transmitter
is used for individual room temperature control
in conjunction with the wireless receiver and
electrothermal actuators (two point). With
switch for the functions heating and cooling.
With switch for the operating modes automatic
operation (in combination with room
thermostat-clock with wireless transmitter),
daytime operation, night setback (choice of 2K
or 4K), off.
With valve protection function.
Temperature range: 5 - 30 °C
The temperature range may be limited by using
the hidden limiting elements.
oventrop
°C
1 5
1 0
5
2 5
3 0
Room thermostat with wireless transmitter
3 V, including 2 batteries, 1.5 V each
(round cells, alkaline, type LR 03 or AAA,
service life approx. 3 years)
115 05 51
Room thermostat-clock with wireless transmitter
3 V, including 2 batteries, 1.5 V each
(round cells, alkaline, type LR 6 or AA service life approx. 2 years)
The room thermostat-clock with wireless
transmitter is used for individual room
temperature control in conjunction with thewireless receiver and electrothermal actuators
(two point).
Functions: heating and cooling.
Timed temperature control. The switching
times and nominal temperatures can be
easily adapted individually. The room
thermostat-clock can be used as master for
further room thermostats.
With valve protection function.
Temperature range: 5–32 °C
115 05 53
Wireless receiver, 1 channel Receiver for 1 room thermostat with wireless
transmitter, item no. 115 05 51/53.
Voltage free switching operation (relay version)
of electrothermal actuators (two point) 24 Vand 230 V.
Functions: heating and cooling.
230 V 115 05 60
Wireless receiver, 4 channels Receiver for 4 or 6 room thermostats with
wireless transmitter, item no. 115 05 51/53.
Electrothermal actuators (two point) 230 V can
be clipped on directly.
Electrothermal actuators (two point) 24 V can
be operated via voltage free contacts, a
separate transformer is required.
Channel 4 or 6 can be used for the activation
of a pump.
Functions: Heating and cooling
230 V, with plug 115 05 61
Wireless receiver, 6 channels
230 V, with plug 115 05 62
Article Article-No. Hint
Room thermostats, actuators, wireless controls
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 100/108100
Wireless receiver with time switch
8 channels
230 V, with plug,
cover with operating device removable
8 channel time switch for a timed
control of up to 8 independent zones
(with room thermostat with wireless
transmitter, item no. 115 05 51/52).
Programming of the time switch
and adaptation of the transmitter
only possible after having removed
the cover (device must be disconnected
from the power supply).
Electrothermal actuators (2 point)
230 V can be connected directly.
Functions:
– Pump logic
– Valve protection function
– Changeover from heating to cooling
via external signal
(incl. battery) 115 05 63
Wireless repeater 115 05 67 The wireless transmitter automatically amplifies
the radio signals received from the room
thermostats with wireless transmitter.
It increases the radio range between the
wireless room thermostats and the wireless
receivers and improves the transmission safety
under difficult conditions.
The radio repeater can be directly plugged into
an earthed plug, the socket can still be used.
230 V
Article Article-No. Hint
Regulating sets for surface heating systems
with bypass valve
Application:
The regulating set with bypass valve is required
for the control of the flow temperature of a
surface heating system, for instance in
combined radiator/surface heating systems.
The required flow temperature is set at the
temperature controller. The electric pipe
contact safety switch switches the circulation
pump off as soon as the set flow temperature
is exceeded. The bypass valve serves to
regulate the flow rate of the surface heating
circuit.
Bypassventil
Vorlaufventil
ElektrischerRohranlegeregler
Temperaturreglermit Anlegefühler
Vorlauftemperaturbegrenzung
Temperature controller withcontact sensor
Supplyvalve
Electric sensorattached to pipe
Bypassvalve
Flow temperature limiting
Example:
For further information see "Technicalinformation".
3 5 4
o v e n t r o p
Set no. 1
for surfaces up to 85 m² 114 42 51
consisting of:
Valve DN 15, brass, nickel plated
straight pattern
item no. 118 01 04 (M 30 x 1.5)
Bypass valve DN 20, brass, nickel plated
straight pattern
item no. 102 76 66
Temperature controller
with contact sensor
and heat transfer unit
capillary 2 m long
control range 20–50 °C
item no. 114 28 61 (M 30 x 1.5)
Electric pipe contact safety switch
with hidden temperature setting
control range 20–90 °C
item no. 114 30 00
Room thermostats, actuators, wireless controls
Regulating sets for surface heating systems
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 101/108101
3 5 4
o v e n t r o p
Set no. 2
for surfaces up to 120 m² 114 42 52
consisting of:
Valve DN 20, brass, nickel plated
straight pattern
item no. 118 71 06 (M 30 x 1,5)
Bypass valve DN 25, brass, nickel plated
straight pattern
item no. 102 76 68
Temperature controller
with contact sensor
and heat transfer unit
capillary 2 m long
control range 20–50 °C
item no. 114 28 61 (M 30 x 1.5)
Electric pipe contact safety switch
with hidden temperature setting
control range 20–90 °C
item no. 114 30 00
Regulating set for surface heating systems
with "Tri D TR" three-way diverting valve
Application:
The regulating set with "Tri-D TR" three-way
diverting valve is required for the control of theflow temperature of a surface heating system,
for instance in combined radiator/surface
heating systems. The required flow rate is set
at the temperature controller. The electric pipe
contact safety switch switches the pump off as
soon as the set flow temperature is exceeded.
Depending on the setting of the temperature
controller, the three-way diverting valve divides
the flow volume into a return flow and a bypass
flow. The check valve installed in the bypass
prevents a wrong flow against the three-way
diverting valve.
Electric sensorattached to pipe
Non-return check valveitem no. 107 20 06
Temperaturecontrolleritem no. 114 28 61
“Tri-D TR” Three-way diverting valve
Example:
3 5 4
o v e n t r o p
OV
I II
III
Set no. 3
for surfaces up to 200 m² 114 42 53
consisting of:
Three-way diverting valve „Tri-D TR“
DN 20 bronze
item no. 113 02 06 (M 30 x 1.5)
Temperature controller
with contact sensor
and heat transfer unit
capillary 2 m long
control range 20–50 °Citem no. 114 28 61 (M 30 x 1,5)
Electric pipe contact safety switch
with hidden temperature setting
control range 20–90 °C
item no. 114 30 00
Piston type spring assisted check valve DN 20
bronze/brass
item no. 107 20 06
Regulating sets for surface heating systems
Article Article-No. Hint
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 102/108102
Return temperature limiter set Packed as a set.
Valve and thermostat "Uni RTLH".
Thermostat "Uni RTLH" limited at works
to 40 °C.Reversed angle connectionconsisting of:
Reversed angle pattern valve for the return pipe and
thermostat “Uni RTLH”
DN 15 0.30 102 83 64
Straight pattern connection
consisting of:
Straight pattern valve for the return pipe and
thermostat “Uni RTLH”
DN 15 0.30 102 84 64
Return temperature limiters
Valves for thermostats "Uni RTLH"
connection thread M 30 x 1.5
brass, nickel plated
Application:
Central heating systems PN 10,
combined radiator/surface heating systems.
Valve insert with double disc prevents
inadvertent overheating, with frost protection.Reversed angle pattern valve for the return pipe
DN 10 0.30 (25) 102 43 63
DN 15 0.30 (25) 102 43 64
Straight pattern valve for the return pipe
DN 10 0.30 (25) 102 44 63
DN 15 0.30 (25) 102 44 64
Article kvsPacking
unit Article-No. Hint
Thermostat "Uni RTLH"
connection thread M 30 x 1.5
With '0' setting,
may be limited or locked.
10-40 °C factory setting
(return temperature) may be increased
to 50 °C by cancelling the limitation (40 °C).white model (25) 102 71 65
chrome plated model (25) 102 71 72
Thermostat "Uni RTL"
connection thread M 30 x 1.5
With '0' setting,
may be limited or locked.
RTL valves with connection thread M 30 x 1.0
are no longer produced.white model (25) 102 71 00
Valve insert
for return flow valves (100) 102 69 81 Valve insert with double disc.
Prevents inadvertent overheating,
with frost protection.
Gland nut
for all RTLH valves
Set = 5 pieces (10) 102 69 86
Return temperature limiter sets
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 103/108103
Individual components for distributor systems Distributor systems for central heating
systems.
If not stated otherwise, all products are madeof brass.
Brass automatic airvent
with automatic shut off
G ⅜ (10) 108 83 03
Vent plug G ⅜
self sealing, set = 10 pieces 140 03 92
self sealing, with coutnernut,
with hose connection (soft seal)
and cap
DN 10 (50) 103 33 13
Flow valve “Series AZ”
for thermostatic control
(to be discontinued)
Valve for the flow distributor of
surface heating systems.
DN 15 G ¾ M x G ¾ F (25) 140 01 64
Return flow lockshield valve “Combi 2”
with presetting and isolating facility
(to be discontinued)
Lockshield valve for the return collector
of underfloor heating systems.
DN 15 G ¾ M x G ¾ F (25) 140 11 94
OV
Brass terminal distributor/collector G 1 female thread
G ¾ male thread for circuit connection
G ⅜ female thread for airvent connection
4 outlets (2) 140 05 54
OV
Brass distributor/collector G 1 female thread x G 1 male thread
G ¾ male thread for circuit connection
2 outlets (2) 140 06 52
OV
3 outlets (2) 140 06 53
OV
4 outlets (2) 140 06 54
OV
Terminal cap G 1 female thread (10) 140 06 91
G ⅜ female thread for airvent connection
G ½ female thread for fill and drain ball valve connection
Ball valve DN 25 (10) 140 63 94
with coupling
flat sealing
Bracket Bracket with mounting clip.
For the installation of the distributor/collector
into the cabinet or onto the wall.
Sound absorbing as per DIN 4109.
steel, galvanised 140 10 61
ArticlePacking
unit Article-No. Hint
Single components for distributors/collectors
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 104/108104
Accessories
0
1
2
34
5
Thermostat with remote control "Uni FH"
white model
capillary 2 m long (40) 101 22 95 with '0' setting
capillary 5 m long (40) 101 22 96
capillary 10 m long (40) 101 22 97
5
4 3
2
1
0
white model,
with additional remote sensor
capillary 2 m long 101 23 95 with '0' setting
capillary 5 m long 101 23 96
Manual heads
white model
The manual head allows the subsequent
conversion to actuators or thermostats without
the necessity to drain the system.connection thread (10) 101 25 65
M 30 x 1.5
0 120
6080
°C
100
40
20
oventrop
Contact thermometer
for distributors/collectors (50) 140 40 95
Coupling
DN 15 (G ¾ c/nut x R ½ M) (50) 101 93 04
Blind plug G ½
self sealing 140 17 04
To close outlets not in use.Cap G ¾ female thread 140 06 92
(not illustr.)
Can be used instead of a cap, but does not
allow the connection of an airvent or a filland drain ball valve.
Cap G 1 female thread 140 06 93(not illustr.)
Ring spanner For the installation of the compression fittings.
Spanner size 30/32 140 10 91
ArticlePacking
unit Article-No. Hint
Single components for distributors/collectors
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 105/108105
"Multidis SF" Stainless steel distributor/collector 1"
for surface heating systems/concrete core activation
with integrated regulating inserts (flow distributor)
flat sealing, with valve inserts M 30 x 1.5
for thermostatic and electronic control
Application:
Stainless steel distributor/collector for central
heating systems with circulation pump.
Max. operating pressure ps: 6 bar (PN 6)
Max. operating temperature ts: 80 °C
Description:
Distributor/collector pre-assembled. With fill
and drain valves, vent plugs and terminal
caps. Heating circuit connections G ¾ male
thread for Oventrop compression fittings.
Flow distributor with integrated regulating
inserts.
Return collector with integrated valve inserts.
Bracket (loosely added) sound-absorbing
according to DIN 4109.
for 2 circuits 140 45 52
for 3 circuits 140 45 53
for 4 circuits 140 45 54
for 5 circuits 140 45 55
for 6 circuits 140 45 56
for 7 circuits 140 45 57
for 8 circuits 140 45 58
for 9 circuits 140 45 59
for 10 circuits 140 45 60
for 11 circuits 140 45 61
for 12 circuits 140 45 62
Further distributors for surface heating: page 2.40
PE-Xc "Copex" Plastic pipes
with oxygen barrier
rolls
Application:
Surface heating and cooling.
Pipes according to DIN 16892/DIN 16893/DIN
EN ISO 15 75/EN 1265-4.
Oxygen tight according to DIN 4726 (all
dimensions).
Further dimensions: page 2.34
Dimension 17 x 2 mm Max. operating pressure ps:
6 bar at 90 °C
10 bar at 60 °Clength per roll 120 m (120) 140 02 51
length per roll 240 m (240) 140 02 52
length per roll 600 m (600) 140 02 54
"Cofit S" Compression fittings
for "Copex" Pe-Xc plastic pipes,
2-fold, metal to metal sealing plus O-ring,
outlet made of bronze,
brass compression ring and collar nut,
collar nut nickel plated
For the connection of the "Copex" PE-Xc
plastic pipes to the distributor/collector and for
couplings.
17 x 2.0 mm x G ¾ collar nut (10) 150 79 37
ArticlePacking
unit Article-No. Hint
Components for concrete core activation
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 106/108106
"Multidis SFI" Brass distributor/collector for
industrial surface heating/concrete core activation
Distributor modules flat sealing,
flow distributor with ball valves,
return collector with regulating valves,
extension to max. 20 circuits by connecting the distributor modules
Application:
Central heating systems with circulation pump.
Max. operating pressure ps: 6 bar (PN 6)
Max. operating temperature ts: 90 °C
Description:
Distributor modules pre-assembled. One port
G 2 male thread, one port G 2 collar nut with G
½ blind plug.
Flow distributor with ball valves.
Return collector with regulating valves.
Heating circuit connections with G 1 male
thread for Oventrop compression fittings.
for 2 circuits 141 44 52
for 3 circuits 141 44 53
for 4 circuits 141 44 54
for 5 circuits 141 44 55
for 6 circuits 141 44 56
PE-Xc "Copex" Plastic pipes
with oxygen barrier
rolls
Application:
Surface heating and cooling.
Pipes according to DIN 16892/DIN 16893/DIN
EN ISO 15 875/EN 1264-4 (except for
dimension 26).
Oxygen tight according to DIN 4726 (all
dimensions).
Dimension 20 x 2 mm Max. operating pressure ps:
6 bar at 90 °C
8 bar at 70 °Clength per roll 240 m (240) 140 03 52
length per roll 600 m (600) 140 03 54
Dimension 26 x 3 mm Max. operating pressure ps:
6 bar at 90 °C
10 bar at 60 °Clength per roll 50 m (50) 140 05 60length per roll 200 m (200) 140 05 62
length per roll 300 m (300) 140 05 63
Dimension 32 x 3 mm Max. operating pressure ps:
6 bar at 90 °C
8 bar at 60 °C
10 bar at 20 °C
length per roll 50 m (50) 140 06 60
"Cofit S" Compression fittings
for "Copex" PE-XC plastic pipes,
2-fold, metal to metal sealing plus O-ring,
outlet bronze / brass resistant to dezincification,
brass compression ring,
brass collar nut, unplated
For the connection of "Copex" PE-Xc plastic
pipes to the distributor/collector and for
couplings.
20 x 3.0 mm x G 1 collar nut (10) 150 79 69
26 x 3.0 mm x G 1 collar nut (10) 150 79 79
Console Consoles with 2 pipe clamps each including
sound insulation supports and quick acting
lock.
Wall attachment included.
for "Multidis SFI" brass 141 44 90
distributor/collector
2-fold, steel galvanised,
adjustable height and depth
Cap G 2 female thread
for "Multidis SFI" brass distributor/
collector, 2-fold, brass
141 44 93 For closing the distributor/collector.
ArticlePacking
unit Article-No. Hint
Components for concrete core activation
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 107/108107
Ball valve
flat sealing
DN 50G 2 F x G 2 M
140 65 86 For isolation of the flow distributors and returncollectors.
"Optiflex" Ball valve
brass, handle with stop
For filling and venting.
self sealing, with coutnernut,
with hose connection (soft seal)
and cap
DN 15 (50) 103 33 14
Pressure test plug
150 60 95
150 60 96
Compressed air pipe connection
150 61 95
150 61 96
ArticlePacking
unit Article-No. Hint
Components for concrete core activation
8/10/2019 Catalog Cofloor
http://slidepdf.com/reader/full/catalog-cofloor 108/108
For further information refer to our catalo-gue and technical data sheets as well asour homepage www.oventrop.de, productrange 2.
Detailed installation instructions can foundon the technical data sheets “Cofloor”.
Subject to technical modification without
Advantages, service
1 The almost ideal “temperature profile”from floor to ceiling.Compared to other heating systems, thesurface heating can be referred to as the
heating system with the ideal temperatureprofile. Depending on its usage, the hotwater surface heating system offers theadvantage that an energy saving of 6 to12% may be achieved due to the lowertemperature of the heating medium and thelower room temperature.
2 As system supplier of the surface heatingand cooling system “Cofloor”, Oventropoffers high quality system solution guaran-teeing maximum benefit for the installationand the later comfort. This does, at thesame time, mean an obligation to observe amultitude of rules and standards.
3, 4 Working supportsOventrop supports its partners regardingplanning, calculation, completion andregulation. Current information materiallike catalogues, technical data sheets andcolour leaflets as well as CDs and softwareare available.
DW8501AT2407
16° 20° 24°
Idealheizung
16° 20° 24°
Fußbodenheizung
16° 20° 24°
Heizkörper Außenwand
2,70 m
1,80 m
0,10 m
Heizkörper Innenwand
16° 20° 24°
1
2 3
o m
Ideal heating Surface heating Radiator outer wallRadiator outer wall Radiator inner wall