 Valves, controls + systems

“Cofloor” surface heating and cooling systemsSystems with distributor/collector

Product range

Innovation + Quality

Page 2: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 2/1082

Content

Content

Page

  2 Content

  3  Summary

  4–5  Systems

  6  Pipes

  7  “Cofloor” base mat system forheating/cooling

  8  Examples of installation

  9  “Cofloor” tacker system and clamp-ing rail system for folded board orbase mat roll for heating/cooling

  10  Examples of installation

  11  “Cofloor” dry-build system for heat-ing/cooling – Accessories

  12  Examples of installation

  13  “Cofloor” dry-build system for heat-ing/cooling with laminate flooring aslayer for load distribution

  14  “Cofloor” system for wall heatingand cooling – Wet-build system

  15  Practical example wall heating andcooling – Wet-build system

  16  “Cofloor” system for wall heatingand cooling – Dry-build system

  17  Practical example wall heating andcooling – Dry-build system

  18  “Cofloor” base mat system NP-R forheating/cooling

  19  “Cofloor system industry for heatingand cooling

  20  Floor construction/Standardconstructions – Base mat, tackerand clamping rail system

  21  Floor construction – Standardconstructions – Dry-build system

  22  Floor construction – Standardconstructions – Base mat NP-R andindustry systems

  23  Performance table for rapid design– Base mat NP and tacker system –PE-Xc pipes “Copex”, PE-RTpipes “Copert” and “Copipe” pipes,14 x 2 mm

  24  Performance table for rapid design– Base mat NP and tacker system– PE-Xc pipes “Copex”, PE-RTpipes “Copert” and “Copipe” pipes,14 x 2 mm, 17 x 2 mm

  25  Performance table for rapid design– Dry-build system – “Copipe”pipes, 14 x 2 mm

  26  Performance table for rapid design– Base mat NP-R system – PE-RTpipes “Copert”, 12 x 2 mm

26-27  Performance charts for differentfloor coverings – PE-Xc pipes“Copex”, PE-RT pipes “Copert” and“Copipe” pipes – Base mat NP andtacker system

  28  Performance charts for differentfloor coverings – “Copipe” pipes –Dry-build system

29-30  Performance charts for differentfloor coverings – PE-RT pipes“Copert” – Base mat NP-R system

  31  Stainless steel distributors/collectors“Multidis SF” for surface heating andcooling systems

  32  Stainless steel distributor/collector“Multidis SFB” with presettable by-pass for surface heating and coolingsystems

  33  Hydronic balancing of the heatingcircuits – Regulation with flow

measuring and regulating device  34  Hydronic balancing of the heatingcircuits – Regulation with regulatinginserts

  35  Brass distributor/collector “MultidisSFI” for industrial surface heatingand cooling systems

  36  Flow temperature control of surfaceheating systems – Control unit“Regufloor H” and boiler connec-tion system “Regumat F-130”

  37  Weather guided flow temperaturecontrol of surface heating systems– Control unit “Regufloor HW”

  38  Flow temperature control of surfaceheating systems – Control unit

“Regufloor HX” with system sepa-ration

  39  “Cofloor” system extension forsurface cooling – Control unit“Regufloor HC” for alternate oper-ation of heating and cooling for alllaying systems

  40  “Cofloor” system extension for sur-face cooling – Heating surfaceregulation for heating and cooling– Example of surface heating andcooling system

  41  Heating circuit regulation of surfaceheating systems – Actuators androom thermostats – Wireless con-trols

  42  Accessories for stainless steeldistributors/collectors – Doubleregulating and commissioningvalves for hydronic balancing –Heat meter connection set

  43  Accessories for stainless steeldistributors/collectors – Differentialpressure regulators for hydronicbalancing – Heat meter connectionset

  44  Dwelling station “Regudis W-HTF”–Integration of surface heating andcooling

  45  “Unibox TSH” / “Unibox T” / UniboxE T” / “Unibox E TC” – Individualroom temperature control in surfaceheating systems

  46  “Unibox RTL” / “Unibox E RTL”“Unibox plus” / “Unibox E plus”

  47  “Unibox vario”, “Unibox E vario”

  48  Application – Installation andassembly

  49  Cabinets – Installation instruc-tions/Dimension chart

  50  Surface-mounted cabinets - Instal-lation instructions/Dimension chart

  51  Surface-mounted cabinets “Regu-floor HX” – Installation instruc-tions/Dimension chart

52-53  Sample form – “Cofloor” materiallist

  54  Sample form – Pressure test record

of the Oventrop surface heatingand cooling system “Cofloor”according to EN 1264-4

  55  Sample form – Heating up record ofthe “Cofloor” base mat, tacker andclamping rail system

  56  Sample form – Heating up record ofthe “Cofloor” dry-build system

  57  Sample form – Heating up record ofthe “Cofloor” base mat NP-Rsystem

  58-107 Illustrated list – “Cofloor” surfaceheating and cooling systems –Extract from the catalogue 2013

108  Advantages, service

Page 3: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 3/1083

Surface heating and cooling system“Cofloor”:practical and functional

With the surface heating/cooling system“Cofloor”, Oventrop offers the specialisttrade not only products of first class qual-ity but also all components required for theeconomical installation of various layingsystems.

This includes base mats, a tacker sys-tem (base mat rolls and folded boards), aclamping rail system, a dry-build system,edge isolating strips, stainless steel dis-tributors/collectors, components for regula-tion and hydronic balancing, cabinets,pipes etc., all complying with standards,coordinated and in accordance with the lat-est technical developments.

Regarding the heating pipes, the user maychose the PE-Xc pipe “Copex”, the compo-sition pipe “Copipe” or the PE-RT pipe“Copert”. All pipes can be laid fast and eas-ily by only one person.

The composition pipe “Copipe” is alsosuitable for supply pipes and for the con-nection to heating or cooling generatorsand distributors/collectors.

 As is generally known, a surface heatingsystem only works perfectly if hydronicbalancing of the mass flow in the supplypipes and heating circuits was carried outcorrectly. A main factor for a trouble-freeoperation of surface heating and coolingsystems is to ensure that the central flowtemperature control in front of the distribu-tor/collector and also the automatic individ-ual room temperature control of each

Summary

circuit at the distributor/collector is func-tioning correctly. This can only be achievedthrough hydronic balancing, i.e. the distri-bution of mass flow according to the heatdemand of the whole system.Oventrop offers a wide-ranging completeprogramme of valves and controls, suitablefor any surface heating system.

Surface heating and cooling:comfortable and economical

The times when energy was wasted care-lessly are over. Nowadays the maxim is“Save energy”. Not only because of thecontinuously rising cost for oil and gas,but also to avoid environmental pollution.This is why the surface heating and to anincreasing extent the surface cooling arebecoming more and more important whenchoosing the heating/cooling system fornew buildings as well as for renovationprojects. Comfort temperatures cannotonly be achieved economically during

heating periods but also during periodsof alternate heating and cooling. Energysavings result from the fact that the heat ina surface heating system spreads evenlyand that the flow temperature of the heat-ing and cooling water does not differ thatmuch from the room temperature (duringheating periods approx. 35°C instead of70°C and during cooling periods not below16°C). Another advantage which, when combinedwith a modern heating and cooling genera-tor, e.g. a low temperature or gross calo-rific boiler, heat pumps or cooled waterfrom a well, reflects in the energy con-sumption. A further energy saving is madeas temperatures can be reduced from thenormal 22°C to 20°C without loosing the“comfort” feeling.Moreover, surface heating stirs up lessdust than radiator systems and dry floorsprevent the build-up of germs, mites andfungus which can cause allergies.

 f o r  b e

 t t e r 

 e n  e r g y  e f f i c i e n  c y.

..

Page 4: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 4/1084

Systems

Base mat system NPFor laying (45° diagonal laying pattern with-out auxiliary material) of 14 or 16 mm Oven-trop PE-Xc pipes “Copex”, PE-RT pipes

“Copert” or composition pipes “Copipe”.Size 1.00 m x 1.00 m with thermal andsound insulation made of expanded poly-styrene, thermal conductivity group 040,types:- thickness 35 mm covered with a poly-  styrene foil,- thickness 11 mm covered with a poly-  styrene foil,- without thermal insulation,

building material class B 2 accordingto DIN 4102.

  Simple and economical laying of pipescarried out by one person only due to thespecial geometric design of the nodules.Clean coverage of joints due to over-lapping polystyrene foil.

Tacker systemBase mat roll or folded board made of ex-panded polystyrene according to DIN EN16163,thermal conductivity group 045 or 040for 30-2 mm,building material class B 2 accordingto DIN 4102,with laminated tissue foil,with imprinted laying screen (screendistance 50 mm),foil overlap on the edge,with adhesive strip on the opposite.Fixing of the Oventrop PE-Xc pipes“Copex”, PE-RT pipes “Copert” or com-position pipes “Copipe” with plastic tackerhooks and tacker machine.

Easily laid and trimmed even in areas withdifficult access.

Dry-build systemDry-build element 1000 x 500 x 25 mmmade of expanded polystyrene accordingto DIN EN 16163,thermal conductivity group 035,building material class B 1 according toDIN 4102.For the simple installation on solid timberbeam floors and wood flooring with the dry-build system (e.g. when renovating olderbuildings) or with heating screed accordingto DIN 18560 on polyethylene foil.The heat/cooling conducting strips allowan either spiral or serpentine patterned lay-

ing of the composition pipe “Copipe” 14 x2 mm. (Oventrop recommends the use of“Copipe” pipes because of their minimalthermal expansion). The Oventrop dry-buildsystem is also suitable for a wall heating orcooling installation.

Clamping rail systemSelf-adhesive clamping rails made of poly-propylene, clamping distance 50 mm,length 1 m, for fixing 14 or 16 mm heatingpipes onto the insulation (base mats orfolded boards). Advantage: laminated tissue foil will not bedamaged by the clamping rail.The clamping rails are also suitable forthe construction of a wall heating or cool-ing installation together with the Oventrop

composition pipe “Copipe” laid in a serpen-tine pattern.

Page 5: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 5/1085

Systems

Base mat system NP-RFor laying (45° diagonal laying pattern with-out auxiliary material) of 12 mm OventropPE-RT pipes “Copert”.

Size 1.00 x 1.00 m, made of moulded poly-styrene foil,with adhesive layer on reverse.The perforation of the base mats allows asimple application and a safe bonding ofthe levelling compound and the existingground.Tested minimum construction heights:- Knauf levelling compound Alphadur 430  min. 17 mm- PCI periplan min. 18 mm- Weber-Maxit weber.floor min. 18 mm- Knauf levelling screed 425 min. 21 mm

Industrial system

Components:- PE-Xc pipes “Copex” (20 x 2 mm and  26 x 3 mm)- Distributor/collector (of modular con-  struction for a maximum of 20 heating

circuits and accessories)- Compression fittings (20 x 2 mm and  26 x 3 mm)For laying of industrial and commercialsurface heating systems, e.g. on reinforce-ment steel mesh.

Page 6: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 6/1086

 Pipes

1

4

2

3

5

1 Composition pipe “Copipe HSC” made ofPE-RT/AL/PE-RTSizes: 14 x 2.0 mm, 16 x 2.0 mm  20 x 2.5 mm, 26 x 3.0 mm

Max. pressure and temperature:6 bar at 90°C, 10 bar at 70°C

2 Composition pipe “Copipe HS” made ofPE-Xc/AL/PE-XcSizes: 14 x 2,0 mm, 16 x 2.0 mm  20 x 2.5 mm, 26 x 3.0 mmMax. pressure and temperature:10 bar at 95°C, 16 bar for cold water

3 PE-Xc plastic pipe “Copex” made ofcross-linked polyethylene (PE-X), with oxy-gen barrierSizes: 14 x 2.0 mm, 16 x 2.0 mm,  17 x 2.0 mm, 20 x 2.0 mm,  26 x 3.0 mmMax. pressure and temperature:6 bar at 90°C, 10 bar at 60°C (8 bar at 70°Cfor 20 x 2.0 mm)

4 PE-RT plastic pipe “Copert” made ofcross-linked polyethylene (PE-RT), withoxygen barrierSizes: 14 x 2.0 mm, 16 x 2.0 mm,  17 x 2.0 mm, 20 x 2.0 mmMax. pressure and temperature:6 bar at 70°C

5 Pressure loss chartfor PE-Xc pipes “Copex” , PE-RT pipes“Copert” and composition pipes “Copipe”sized 14 x 2.0 mm, 16 x 2.0 mm,17 x 2.0 mm and 20 x 2.0 mm.With flow velocity indication of the heatingwater.

Flow of heating water mFluid [kg/h]

   R  e  s   i  s   t  a  n  c  e   R   [  m   b  a  r   /  m   ]

Flow of heating water mFluid [kg/s]

   R  e  s   i  s   t  a  n  c  e   R   [   P  a  s  c  a   l   /  m   ]

Page 7: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 7/1087

“Cofloor” base mat systemfor heating/cooling

1

1 The Oventrop base mat system “Cofloor”with its coordinated components allows afast laying of the pipes by only one person.

The Oventrop base mats NP-35 and NP-11are a suitable thermal and sound insulationmade of expanded polystyrene, thermalconductivity group 040, covered with apolystyrene foil, building material class B 2,which is laid directly onto concrete screedor, if required, onto the additional insulation.

The special grid pattern (50 mm betweenthe nodules) is suitable for 14 or 16 mm PE- Xc pipes “Copex”, PE-RT pipes “Copert”and composition pipes “Copipe”.

The handy base mats have practically nowastage. They can be laid economicallyand easily in any room whether it is smallwith many angles or with a large surfacearea.

Laying base mats in larger rooms starts ina corner opposite the entrance door. Theouter rows of the base mats are connectedlike a press button closure. At the end ofthe room the base mats can be cut to sizeas required. Any off cuts can be used in thesame order.

By using the polyethylene foil of the edgeisolating strip and the overlap of the basemat, the floor surface is completely coveredand ready for the concrete or liquid screedto be laid.

Therefore a sound bridge to the raw con-crete flooring is avoided.

Several types of base mats are availablewith varying thickness of insulation: NP-35,NP-11 and the foil base mat NP-R (withoutthermal insulation made of polystyrene).

2 The nodules of the polystyrene foil (NP-35and NP-11) are filled with polystyrene foam.This increases the firmness of the nodulesfor the pipe fixing and secures the heatingor cooling pipes firmly.

Improved sound insulation of the basemat with a thickness of 35-2 mm:28 dB

2

Page 8: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 8/1088

Examples of installation

5

3 4

6 7

1 The handy base mats NP-35 (illustr.) andNP-11 are thermal and sound insulated.If required, additional insulation has to beconsidered, see notes on page 20.

2 The systematic laying begins by placingthe edge isolating strip along the walls.The edge isolating strip has an additionalbonded foil, allowing a sufficient sealing ofthe surface for use with concrete or liquidscreed.

3 The tight fitting of the base mats at theedges is ensured through a continuedgrooved edging. Like a press button clos-ure, the overlap is pressed onto the firstrow of nodules of the adjoining mat andthus closes the area off completely (mostimportant when using liquid screed).

4 The strong structure of the nodules andthe clear grid pattern of 50 mm allow aclean and simple fitting of the pipes by only

one person with the calculated distance ofthe pipes being maintained.

5 The coil unwinder allows and easy andclean laying of the pipes on the mats.

6 In doorways and passages, an expansionstrip separates individual floor areas fromeach other. A slit corrugated pipe sleeveprotects the pipes where they cross over.

7 Having submitted the surface heatingpipes to a pressure test, concrete can belaid.

1 2

Page 9: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 9/1089

“Cofloor” tacker system and clamping rail systemfor folded board or base mat roll

for heating/cooling

2

4

3

1

1 The economical Oventrop “Cofloor”tacker and clamping rail systems for foldedboard and base mat roll consist of a foldedboard 2 x 1 m or a base mat roll 10 x 1 m

for use with concrete or anhydrite liquidscreed. The folded board and base mat rollare made of expanded polystyrene and arelaminated with a tissue foil with an imprin-ted laying screen (screen distance 50 mm).

One longitudinal edge of the folded boardand of the base mat roll has a foil overlapand the opposite edge is equipped with anadhesive tape preventing the penetrationof humidity into the underlying insulationwhen applying concrete or anhydrite liquidscreed.

The folded board and base mat roll areclassed in the thermal conductivity group045 and 040 for 30-2 mm, building mate-rial class B 2 according to DIN 4102 with amaximum load of 4 kN/m² and 5 kN/m² for30-2 mm.

The 14, 16 or 17 mm Oventrop PE-Xcplastic pipes “Copex”, PE-RT plastic pipes“Copert” as well as the composition pipes“Copipe” are fixed onto the folded boardor base mat roll with tacker hooks or self-adhesive clamping rails made of polypropy-lene.

The folded boards and base mat rolls arelaid directly onto the concrete screed or, ifrequired, onto the additional insulation.

The Oventrop folded boards or base matrolls are laid in the same manner as thebase mats, starting in a corner of the roomopposite the entrance door. Off cuts can beused in the same order which leaves mini-mum wastage.

The “Cofloor” folded boards, base matrolls, tacker hocks or clamping rails allowan economical, quick and simple laying ofall components.

The imprinted laying screen makes it easyto lay the pipes either in a spiral or serpen-tine pattern.

The tissue foil ensures a secure fixing of thetacker hooks and/or the clean fitting of theself-adhesive clamping rails.

2,3  Due to the imprinted 50 mm layingscreen on the foil, Oventrop folded boardsor base mat rolls reflect a clean and orderlypicture of the pipework with 14, 16 or 17

mm PE-Xc pipes “Copex”, PE-RT pipes“Copert” or composition pipes “Copipe”.The clear lines of the laying screen make itvery easy to tack the pipes in a straight linewith the handy Oventrop tacker machine.

4 Self-adhesive clamping rails made ofpolypropylene, clamping distance 50mm, for 14 or 16 mm PE-Xc plastic pipes“Copex”, PE-RT plastic pipes “Copert” orcomposition pipes “Copipe” .

Length of rail 1 m; for fixing the pipe ontothe insulation.Improved sound insulation of the basemat roll with a thickness of20-2 mm, 26 dB35-2 mm, 29 dB30-3 mm, 29 dB25-2 mm, 28 dB30-2 mm, 28 dB

Page 10: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 10/10810

 Examples of installation

3 4

6

75

1 Laying of the “Cofloor” system “foldedboard” starts at the edge isolating stripat the right hand side wall in the relevantroom. The 100 x 200 cm folded board with

the reinforced tissue foil allows a fast lay-ing of the base. If required, an additionalinsulation should be considered (see page20 for further details).

2 If liquid screed is to be used, then theedge isolating strip must be additionallysealed (e.g. using a tape gun with self-adhesive tape).

3 One longitudinal edge of the folded boardand of the base mat roll has a foil overlapand the opposite edge is equipped withan adhesive tape which is covered with aplastic strip.

4 Laying the base mat roll (10 x 1 m). Ma-terial and process are identical to thoseused for the folded boards.

5 By using the Oventrop tacker machine,laying can be carried out economicallyby one single person. The 50 mm layingscreen imprinted on the foil, helps to fit thepipes in clear and straight lines. The sta-bility and strength of the tacker hooks andtissue foil ensure that the pipes are fixedsecurely.

6,7 The “Cofloor” clamping rail system(length = 1 m) with a self-adhesive strip for14 and 16 mm pipes, allows a clean andfast pipe fixing without damaging the tissuefoil. This also means that it is an additionaladvantage when using liquid screed.

1 2

Page 11: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 11/10811

 “Cofloor” dry-build system for heating/cooling Accessories

2

4

3

1

1 Apart from the base mat system and thetacker system where wet concrete is used,Oventrop offers the “Cofloor” dry-build sys-tem. The components of the dry-build sys-

tem are suitable for renovating old buildingsas well as for new buildings. The Oventropdry-build surface heating/cooling systemcan be combined with standard dry flooringelements (such as Fermacell boards) butalso with normal concrete or liquid screed.

The “Cofloor” dry-build basic element con-sists of 25 mm thick polystyrene foam.It serves as thermal insulation and at thesame time as carrier for the individual dry-build heat/cooling conducting strips. Thespecific order of the grooves of the basicelement allows the Oventrop 14 x 2 mmcomposition pipe “Copipe” to be laid eitherin a spiral or serpentine pattern.Other patterns are also possible.

Oventrop recommends using the compo-sition pipe “Copipe” as it has a lower ex-pansion coefficient than the PE-Xc/PE-RTplastic pipes. A quiet operation within theheat/cooling conducting strips is thereforecertain.

The strips made of galvanised sheet steelwith a thickness of 0.4-0.5 mm are the opti-mum heat/cooling conductor into the dryflooring elements or the concrete or liquidscreed.

The practical pre-punched breaks points ofthe strips (998 mm long) allow an optimumplacement in any room.

 Advantages:- the installation of the Oventrop dry-build

system “Cofloor” is without wastage andcan be carried out by only one person

- overall height is reduced compared to wetscreeds

- optimum heating/cooling output via thegalvanised steel sheet strips and elbows

- no delay in the building progress whendry flooring elements are installed

- no warm up period is to be observed withdry flooring elements

- the floor can be walked on immediatelyafter installation

The Oventrop dry-build system “Cofloor”can be used for wall heating/cooling evenwhen pipes are installed in a serpentinepattern.

2 Dry-build element made of expanded

polystyrene (1000 x 500 x 25 mm) with agrooved pattern for fully fitting any room.

3 Heat/cooling conducting strips installedas 90° elbow for spiral patterned laying.

4 Installed heat/cooling conducting elbowwhere the pipe loops in a serpentine pat-terned layout.

Page 12: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 12/10812

 Examples of installation

5 6

3 4

7

1 2

1 Installation of the heat/cooling conduct-ing strips (998 x 122 x 0.4 mm) with pre-punched break points in the grooves of thedry-build element.

2 Installation of the heat/cooling conductingelbows (110 x 245 x 0.5 mm) with squeezefit design, allowing the pipes to be held inthe elbow without tension.

3,4 Simple laying of the Oventrop compo-sition pipe “Copipe” by just one person intothe preformed channel of the heat/coolingconducting strips and elbows.

5 Edge isolating strip and pipe conduit forfeeding pipe through the wall for dry-buildsystem.

6 Cutting individual pipe channels into theinfill channel, using the hot cutting machine.

7 Covering the installed pipes in the dry-build element with 0.2 mm polyethylene foil

for separation purposes.Quick calculation/ Determination of required material:

Required material for spiral patternedlayout of composition pipe “Copipe”14 x 2 mm:

per m² dry-build element:

7.70 m heat/cooling conducting steelsheets*)

Composition pipe “Copipe”*)⩠ 

4.00 m for laying distance 250 mm⩠  8.00 m for laying distance 125 mm

Required material for serpentine patternedlayout of composition pipe “Copipe”

14 x 2 mm:per m² dry-build element:

approx. 8.00 m heat/cooling conductingsteel sheets*)

deduct

number/surface of heat/cooling conductingsteel sheets where pipe loops (size of theheat/cooling conducting elbows110 x 245 x 0.5 mm)

Composition pipe “Copipe”*)⩠ 

4.00 m for laying distance 250 mm⩠  8.00 m for laying distance 125 mm

Please note:*) These figures are only a guide and do

not replace the exact layout and calcula-  tion with the Oventrop software “OVplan”

Page 13: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 13/108

Page 14: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 14/108

Page 15: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 15/10815

Practical example wall heating and coolingWet-build system

2

4

3

1 Snap clamping rails together to the re-quired length. Tear off foil. Bond clampingrails onto insulation board or wall and fixonto the brickwork/base with suitable wall

fixings (dowel).(Max. laying distance between clampingrails: 80 cm – vertical)

2 Feed composition pipe “Copipe” from thesupply of the distributor to the wall heat-ing/cooling. Now, starting from the bottom,press the pipe into the clamping rails in ahorizontal serpentine pattern. (Laying dis-tance depending on the model is 10 – 20cm.)

3 A space of 5 cm should be left at theedges for plastering (from the pipe edgeto the end of the wall heating surface). Theinstallation of a venting facility is recom-mended.

4 Lower edge connection of the wall heat-

ing system to the continuing pipework.

1

 Venting

SupplyReturn

Screed

Bare floor

Page 16: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 16/10816

“Cofloor” system for wall heating and coolingDry-build system

2

1

The large wall surfaces of a room are idealfor the installation of a heating or cool-ing system with composition pipes (e.g.“Copipe”).

Wall heating or cooling systems are lowtemperature systems. The temperatureof the heating medium or coolant is onlyslightly above or below the room tempera-ture and most of the energy is radiated.

With the Oventrop “Cofloor” dry-build wallheating and cooling system, the pipes withthe conducting strips and elbows are inte-grated in the thermal insulation. Due tothe large-surface covering of the dry-buildelements, the conducting strips allow atransmission of the heat into the room viathe wall finish.

The dry-build elements serve as insulationand carrier for the conducting strips andelbows. The pre-punched break points of

the strips allow an optimum covering of thewall surfaces.

Provided that no additional insulation isrequired, the dry-build elements are fixeddirectly onto the wall between wood bat-tens for plaster work. If an additional insu-lation layer is required, it has to be fixedfirmly onto the bare wall.

The wall is normally covered with dry-buildboards with a thickness of 12.5 cm whichare fixed onto the battens. The dry-buildboards are covered with the required wallfinish (wall paper, structural plaster, paint,tiles, etc.).

The dry-build wall heating and cooling sys-tems reduces the time of construction.

Due to the dry-build system, no humiditypenetrates the wall.

Contrary to floor surfaces, wall surfacesdo not represent a direct contact surface,so the surface temperature can be slightlyhigher during heating periods. For reasonsof comfort it is, however, recommended notto exceed an average surface temperatureof 40°C during heating periods. The maxi-mum temperature load of the wall finishmay reduce this limit. The maximum per-missible flow temperatures contained withinthe instructions of the dry-build boardmanufacturers must be observed.

 As with underfloor heating, an incrementalheating test has to be carried out for wall

heating/cooling systems. This will confirmthat it functions correctly but is not intend-ed to dry the wall construction. Procedureand documentation must be carried out inaccordance with the dry-build board manu-facturer’s instructions.

1 Wall surface with thermal insulation

2 Wall surface without thermal insulation

Wall construction of adry-build system withthermal insulation(e.g. inner wall)

Brickwork

Battens for plaster work

Insulation

Pipe

Conducting strip

Dry-build element

Dry-build board

Wall finish

Wall construction of adry-build system without

thermal insulation(e.g. inner wall)

Brickwork

Battens for plaster work

PipeConducting strip

Dry-build element

Dry-build board

Wall finish

Page 17: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 17/108

Page 18: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 18/108

Page 19: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 19/10819

  “Cofloor” system industryfor heating/cooling

2

3

4

1

54

3

1

2

2

4

5

7, 8

7, 8

9

6

1 Surface heating and cooling systems forcommercial and industrial buildings arebecoming more and more important.The advantages of surface heating and

cooling systems in residential buildings canalso be used for industrial buildings.Oventrop offers high quality system com-ponents for a professional installation of theindustrial “Cofloor” system.

2 System components:1 Brass distributor/collector “Multidis SFI”

of modular construction, extendable upto a maximum of 20 heating circuits

2 Cap  for closing the flow distributor and

return collector3 Console  for fixing the brass distributor/collector

“Multidis SFI”4 Ball valve “Optiflex”  for filling and venting

5 Ball valve “Optibal”  for the isolation of the flow distributor

and return collector6 Compression fittings “Cofit S”  20 x 2 mm x G 1 collar nut  20 x 3 mm x G 1 collar nut  for the connection of the PE-Xc pipes

“Copex” to the distributor/collector7,8 Composition pipe “Copipe” and press

fittings “Cofit P” for a quick and safeconnection of the distributor/collectoron the riser side

9 PE-Xc pipe “Copex”  Diffusion tight pipe for the professio-  nal installation in the Oventrop industrial

“Cofloor” system

3 Industrial hall

4 Distributor/collector “Multidis SFI”

Page 20: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 20/10820

Floor construction/Standard constructionsBase mat, tacker and clamping rail system

3 4

1 2

5 6

The EN 1264-4 standard and the EnergySaving Directive describe the minimumrequirements regarding the thermal insula-tion of surface heating systems. Higher

demands can be defined by the specifyingengineer.The following standard constructions of thesurface heating system “Cofloor” with thebase mat NP-35, the base mat roll or thefolded board as pipe backing, thermal andsound insulation derive from this.

Effective thickness of insulation layer:  35 mm (both systems)Thermal conductivity group:  040 base mat NP-35  045 base mat roll/folded boardSound absorption:  28 dB base mat NP-35  29 dB base mat roll/folded boardOverall height:  54 mm base mat NP-35

  35 mm base mat roll/folded boardElasticity under pressure:  2 mm base mat NP-35  3 mm base mat roll/folded boardMax. load:  5 kN/m² base mat NP-35  4 kN/m² base mat roll/folded boardScreed volume (both systems) with a pipecovering of:  45 mm (approx. 65 mm screed):  approx. 60 l/m²  30 mm (approx. 50 mm screed):  approx. 45 l/m²

1,2 Underfloor heating above a heatedroomInsulation layer according to DIN EN1264-4 with base mat, base mat roll or

folded board: 35 mmThermal resistivity: R ≥ 0.75 (m²K)/W

3,4 Underfloor heating above unheatedrooms, rooms heated at irregular inter-vals or on flooring in direct contact withthe groundInsulation layer according to DIN EN1264-4 with base mat, base mat roll orfolded board: 35 mmand expanded polystyrene, thermal con-ductivity group 040: 20 mmThermal resistivity: R ≥ 1.25 (m²K)/W

5,6 Underfloor heating of a flooring withoutside air from belowInsulation layer according to DIN EN1264-4 with base mat, base mat roll or

folded board: 35 mmand expanded polystyrene, thermal con-ductivity group 040: 50 mmThermal resistivity: R ≥ 2.0 (m²K)/WSealing of buildings according to DIN18195 below the insulation layer:approx. 2 mm

Example of a floor constructionaccording to points 3, 4(valid for both systems):hC = Floor covering, e.g. 10 mmhS = Screed, e.g. +65 mmhI = Insulation layer +35 mmh AI = Additional insulation +20 mmOverall height, e.g. 130 mm

hB

hDhZ

hE

hB

hDhZ

hE

hB

hDhZ

hE

hC

hS

hI

h AI

hC

hS

hI

h AI

hC

hS

hI

h AI

Page 21: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 21/10821

Floor constructionStandard constructions

Dry-build system

1 2

5 6

3 4

Using the dry-build system as pipe backingand thermal insulation, the following stan-dard construction of the “Cofloor” surfaceheating is derived from the DIN EN 1264-4

standard and the Energy Saving Directive.Thickness of dry-build element: 25.0 mmEffective thickness ofinsulation layer: 17.5 mmThermal conductivity group: 035Max. load (dry-build element): 60 kN/m²Construction height ofdry flooring elements: 25.0 mm

1,2 Underfloor heating above a heatedroomInsulation layer according to DIN EN1264-4 with dry-build element: 25.0 mmand expended polystyrene035 DEO: 10.0 mmThermal resistivity: R ≥ 0.75 (m²K)/W

3,4 Underfloor heating above unheated

rooms, rooms heated at irregular inter-vals or on flooring in direct contact withthe groundInsulation layer according to DIN EN1264-4 with dry-build element: 25.0 mmand expended polystyrene035 DEO: 30.0 mmThermal resistivity: R ≥ 1.25 (m²K)/W

5,6 Underfloor heating of a flooring withoutside air from belowInsulation layer according to DIN EN1264-4 with dry-build element: 25.0 mmand expended polystyrene035 DEO: 55.0 mmThermal resistivity: R ≥ 2.0 (m²K)/WSealing of buildings according to DIN18195 below the insulation layer:

approx. 2 mmExample of a floor construction accord-ing to points 3, 4:hC = Floor covering, e.g. 10 mmhS = Screed, e.g. +25 mmhI = Insulation layer +25 mmh AI = Additional insulation +20 mmOverall height, e.g. 90 mm

hBhEhD

hB

hEhDhZ

hB

hDhZ

hE

hC

hS

hI

hC

hS

hI

h AI

hC

hS

hI

h AI

Page 22: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 22/10822

Floor constructionStandard constructions

Base mat NP-R and industry systems

3 4

1 2

1,2 Underfloor heating above a heated orunheated room without insulation layerTogether with the corresponding levellingcompound, the system is laid directly onto

the existing flooring or the bare floor as acompound construction.- The manufacturer’s specifications of the

levelling compound must be observed.- The overall height is related to a com-  pound construction on existing flooring or

the bare floor.- In systems with additional insulation

layers, the manufacturer’s specificationsof the levelling compound must be strictlyobserved (for instance regarding an in-

  crease of the minimum covering).

3,4 Industrial floor heating in directcontact with the groundThe brass distributors/collectors “MultidisSFI” are used for the connection of heat-ing/cooling circuits in industrial surface

heating and cooling systems.The floor construction for the individualprojects is specified by the productionengineer and the structural engineer.

Page 23: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 23/10823

Performance table for the rapid designBase mat NP and tacker system

PE-Xc pipes “Copex”, PE-RT pipes “Copert” and“Copipe” pipes, 14 x 2 mm

Page 24: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 24/10824

Performance table for the rapid designBase mat NP and tacker system

PE-Xc pipes “Copex”, PE-RT pipes “Copert” and“Copipe” pipes, 16 x 2 mm, 17 x 2 mm

Page 25: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 25/10825

Performance table for the rapid designDry-build system

“Copipe” pipes, 14 x 2 mm

Page 26: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 26/108

Page 27: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 27/10827

Information for all performance charts:

Due to minimal deviations, the performancecharts show average values. Thereforesurface heating systems with PE-Xc pipes“Copex”, PE-RT pipes “Copert” and

composition pipes “Copipe” sized 14 x2 mm, 16 x 2 mm and 17 x 2 mm can becalculated.

 Verlegeabstand

in mm 50 100 150 200 250 300

   W   ä  r  m  e  s   t  r  o  m   d   i  c   h   t  e  q   [   W   /  m   2   ]

200

180

160

140

120

100

80

60

40

20

0

0 10 20 30 40 50 60 70 80

Heizmittelübertemperatur ∆ΘH [K]

Grenzkurve

Randzone

Grenzkurve

 Aufenthaltszone

und Bad

 Verlegeabstand

in mm 50 100 150 200

   W   ä  r  m  e  s   t  r  o  m   d   i  c   h

   t  e  q   [   W   /  m   2   ]

200

180

160

140

120

100

80

60

40

20

0

0 10 20 30 40 50 60 70 80

Heizmittelübertemperatur ∆ΘH [K]

250

300Grenzkurve

Randzone

Grenzkurve Aufenthaltszone

und Bad

Performance chart

for RλC = 0.10 (m²·K)/W

Floor covering: e.g. carpet,concrete, calcium sulphate or anhydritescreed, pipe covering 45 mm

Performance chart

for RλC = 0.15 (m²·K)/WFloor covering: e.g. thick pile carpet,concrete, calcium sulphate or anhydritescreed, pipe covering 45 mm

   H  e  a   t   f   l  o  w   d  e  n  s   i   t  y  q   [   W   /  m   ²   ]

Laying distancein mm

Heating medium excess temperature ΔΘFluid [K]

Limiting curveFringe area

Limiting curveResidential areabathroom

   H  e  a   t   f   l  o  w   d  e  n  s   i   t  y  q   [   W   /  m   ²   ]

Laying distancein mm

Heating medium excess temperature ΔΘFluid [K]

Limiting curve

Fringe area

Limiting curveResidential areabathroom

  Performance charts for different floor coveringsPE-Xc pipes “Copex”, PE-RT pipes “Copert” and “Copipe” pipes

Base mat NP and tacker system

Page 28: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 28/108

Page 29: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 29/10829

Pipe distance RA = 0.050 m

Heating medium excess temperature in K

Limiting curve dT:9K Limiting curve dT:15K

Pipe distance RA = 0.050 m

   H  e  a   t   f   l  o  w   d  e  n  s   i   t  y   i  n   W  m   2

Pipe distance RA = 0.075 m

Limiting curve dT:9K Limiting curve dT:15K

Heating medium excess temperature in K

Pipe distance RA = 0.075 m

   H  e  a   t   f   l  o  w   d  e  n  s   i   t  y   i  n   W  m   2

Pipe distance = 0.100 m

Limiting curve dT:9K Limiting curve dT:15K

Heating medium excess temperature in K

Pipe distance RA = 0.100 m

   H  e  a   t   f   l  o  w   d  e  n  s   i   t  y   i  n   W  m   2

Performance charts for different floor coveringsPE-RT pipes “Copert”

Base mat NP-R system

Page 30: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 30/10830

Limiting curve dT:9K Limiting curve dT:15K

Heating medium excess temperature in K

Pipe distance RA = 0.150 m

   H  e  a   t   f   l  o  w   d  e  n  s   i   t  y   i  n   W  m   2

Limiting curve dT:9K Limiting curve dT:15K

Heating medium excess temperature in K

Pipe distance RA = 0.200 m

   H  e  a   t   f   l  o  w   d  e  n  s   i   t  y   i  n   W  m   2

Pipe distance RA = 0.150 m

Pipe distance RA = 0.200 m

Pipe distance RA = 0.250 m

Limiting curve dT:9K Limiting curve dT:15K

Heating medium excess temperature in K

Pipe distance RA = 0.250 m

   H  e  a   t   f   l  o  w   d  e  n  s   i   t  y   i  n   W  m   2

Performance charts for different floor coveringsPE-RT pipes “Copert”

Base mat NP-R system

Page 31: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 31/10831

Stainless steel distributors/collectors “Multidis SF”for surface heating and cooling system

The Oventrop stainless steel distributors/ collectors “Multidis SF” allow a central dis-tribution of the heating or cooling water tothe different circuits of each dwelling unit.

The Oventrop distributors/collectors aredesigned for surface heating and coolingsystems with circulation pump.

The supply and the return pipe may beconnected either on the left or right handside.The brackets allow the fixing of the distribu-tor/collector in the cabinet or directly ontothe wall.When using a heat meter, its lengths haveto be taken into consideration when choo-sing the cabinet.To enlarge the depth of the cabinet, theframe and the door have to be pulled out.

The ball valve DN 25 with temperature sen-sor connection M 30 x 1, item no. 140 67 08,can be used at the supply of the stainlesssteel distributor/collector “Multidis SF”.Hydronic balancing of the installation iscarried out with the help of the integratedinserts of the return collector.

1 Stainless steel distributor/collector “Multi-dis SF” with integrated flow measuring andregulating devices 0-5 l/min. in the flowdistributor. As for the distributor/collector, item no.140 43, the calculated flow rate is set at thehandwheel of the flow measuring andregulating device. The set value can beread off the viewing glass with scale(0-5 l/min.). Each heating/cooling circuitcan be isolated without modification of theset flow rate which means that the set flowrate is re-stored after reopening an isolatedheating/cooling circuit. The functions “set-ting” and “isolation” are thus autonomous.

2 Stainless steel distributor/collector “Multi-dis SF” with integrated regulating inserts inthe flow distributor. As for the distributor/collector, item no.140 45, regulation is carried out accordingto a chart (see technical information).The calculated flow rate is set at the hiddenstem of the regulating insert. A reproduciblepresetting is possible.

Oventrop offers a calculation programmefor the design of a surface heating systemwith composition pipe “Copipe”. The valveinserts M 30 x 1.5 in the return collec-tor which are convertible to thermostatic

operation allow the individual room tem-perature control prescribed in the EnergySaving Directive. The Oventrop electro-thermal actuators and room thermostats orthermostats with remote control which areavailable as accessories, are used for thispurpose.

3 Dimensions “Multidis SF”

1 2

3

Item no. Outlets Length LLength with

ball valves e. g. 140 64/65 83

140 43 52 2 190 mm 263 mm

140 43 53 3 240 mm 313 mm

140 43 54 4 290 mm 363 mm

140 43 55 5 340 mm 413 mm

140 43 56 6 390 mm 463 mm

140 43 57 7 440 mm 513 mm

140 43 58 8 490 mm 563 mm

140 43 59 9 540 mm 613 mm140 43 60 10 590 mm 663 mm

140 43 61 11 640 mm 713 mm

140 43 62 12 690 mm 763 mm

 Actuator

Page 32: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 32/108

Page 33: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 33/10833

Hydronic balancing of the heating circuitsRegulation with flow measuring and regulating device

1

3

2

4

 As with any heating system, a hydronicbalance according to DIN 18380 is alsorequired for the surface heating system.

Regulation of the surface heating circuit iscarried out at:Stainless steel distributor/collector“Multidis SF”, item no. 140 43 52 to140 43 62,via the flow measuring and regulating de-vices at the flow distributor.

Setting is carried out whilst the circulationpump is in operation.

 All valves of the heating circuit are to befully open.1 Lift the locking ring until it clicks into

position.2 Wind up locking cap.3 Set the calculated flow rate by turning the

red handwheel of the first flow measuringand regulating device.

The set value can be read off at the redindicator ring inside the viewing glass.The scale shows values between 0 and5 l/min. Carry out setting of all heatingcircuits.

  The first values are checked andreadjusted if required.

4 With the setting being completed, closelocking cap until stop. Protect setting ofthe flow measuring and regulating de-

  vices by pushing the locking ring downuntil it clicks into position.

Isolation and openingEach heating circuit can be isolated with-out modification of the set flow rate whichmeans that the set flow rate is restoredafter reopening an isolated heating/cooling

circuit. The functions “setting” and “isola-tion” are thus autonomous.

1 Isolation:The heating circuit is closed by turning thered handwheel clockwise until stop.

2 Opening:Turn the red handwheel anticlockwise untilstop. The flow measuring and regulatingdevice is opened and the set flow rate isrestored.

Page 34: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 34/10834

Hydronic balancing of the heating circuitsRegulation with regulating inserts

Regulation of the surface heating circuit iscarried out at:

Stainless steel distributor/collector“Multidis SF”, item no. 140 45 52 to140 45 62andStainless steel distributor/collector“Multidis SFB, item no. 140 44 52 to140 44 62

via the regulating inserts at the return col-lector:

1 Unscrew black cap, use an Allen key(size 5) if necessary.

2 Close regulating stem by turning the Allenkey (size 5) clockwise.

  Then, open regulating stem to the calcu-  lated presetting by turning it anticlock-  wise.  (Example: Calculated presetting PSR =

2.5 – open stem by 2.5 turns, seepressure loss chart)

3 Turn black setting screw clockwise withan Allen key (size 6) up to the regulatingstem. This way, the setting can be easilylocated again, if for instance the heatingcircuit is closed at a later time by use ofthe regulating stem.

4 Replace black cap and tighten with an Allen key (size 5) if necessary.

Repeat the same process for all heatingcircuits.

210

8

10

104

2

10

2

3

6

4

2

3

10

1

3

2

4

6

8

0.8

0.6

0.4

0.3

2

3

8

6

4

3

2

103

210

2

3

4

6

8

8

6

4

3

2 3 4 6 81 2 3 4 6 8 1086432

1 1.5 2 2.5 3 3.5 4.5   54

   m  a   x

 .

3

Umdrehungen

   D  r  u  c   k  v  e  r   l  u  s   t      ∆  p   [  m   b  a  r   ]

   D  r  u  c   k  v  e  r   l  u  s   t      ∆  p   [   P  a  s  c  a   l   ]

Flow of heating water mFluid [kg/h]

1 2

3 4

SW 5

SW 6

Pressure loss chartfor regulating inserts at the return collectorof the stainless steel distributor/collector“Multidis SF”. Valve inserts of the flow distributor fullyopen.

Turns

   P  r  e  s  s  u  r  e   l  o  s  s      ∆  p   [  m   b  a  r   ]

   P  r  e  s  s  u  r  e   l  o  s  s      ∆  p   P  a  s  c  a   l

Page 35: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 35/10835

Brass distributor/collector “Multidis SFI“ forindustrial surface heating and cooling systems

Surface heating and cooling systems forcommercial and industrial buildings arebecoming more and more important. Theceiling heights of these buildings are usu-

ally very high and therefore an even andeconomical distribution of the required tem-perature is needed. Utilising the large sur-face area together with a favourable verticaltemperature profile fulfils this demand.

The integration of the surface heatingsystem within the ground floor allows aninterior design that is free and flexible.Conventional visible heating systems haveto be cleaned and serviced regularly, butindustrial surface heating systems do norequire individual maintenance. Surfaceheating in commercial and industrial build-ings is therefore a heat distribution systemwhich is economical and energy efficientand with technical effort it can also be usedfor cooling.

1 The brass distributors/collectors “Multi-dis SFI” allow a central distribution of theheating or cooling water to the differentcircuits of an industrial surface heating/ cooling system. It is recommended to equipthe distributors/collectors with ball valvesDN 50. They allow the isolation of the sup-ply and return pipe, e.g. for maintenancework. Consoles with pipe clamps (includingsound insulation supports) allow a fixing ofthe distributor/collector onto the wall.

The ball valve at the flow distributor and theregulating valve at the return collector allowthe isolation of each heating circuit.

2 Summary with system componentsFive different distributor modules with two

to six heating circuit connections allow anindividual combination of up to 20 circuits.The individual modules are interconnectedwith flat seals. The distributor/collectorends are closed with plugs.

3 PE-Xc plastic pipes “Copex” sized 20 x 2mmand 26 x 3 mm can be connected to theheating circuit connections of the brassdistributor/collector “Multidis SFI” with cor-responding compression fittings. The pipesare made of cross-linked polyethylene andare oxygen tight according to DIN 4726.

The sheltered oxygen barrier protects thePE-Xc plastic pipes “Copex” against dam-ages on site.

4 Hydronic balancing of the individual sur-

face heating circuits has to be carried out inaccordance with the VOB DIN 18380 stand-ard. Regulation is carried out at the regula-ting valves integrated in the return collec-tor of the “Multidis SFI”.

1

2

3

4

Ball valve

Ball valve“Optiflex” ball valve

Console

“Optiflex” ball valve

Distributor/collectorfor 4 circuits

Distributor/collectorfor 4 circuits

Cap2-fold

 Valve stem Cap

Bonding agent

Oxygen barrier

Bonding agent

PE-Xc

PE-Xc

Page 36: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 36/10836

Flow temperature control of surface heating systemsControl unit “Regufloor H” and

boiler connection system “Regumat F-130”

Economy and comfort of a surface heatingsystem can only be achieved if the correctlycalculated pipe layout and floor constructionis adhered to. Moreover, a temperature and

flow control of the heating medium adaptedto the surface heating must be taken intoconsideration.The main points of the regulation are theprovision of a permissible flow temperatureof the heating medium (this should beseparate from the boiler regulation) and thedistribution of mass flow in the individualheating circuits of the stainless steel dis-tributor/collector.

1 Control unit “Regufloor H”Fixed value control unit for the connectionto the stainless steel distributors/collectors“Multidis SF” for surface heating which alsosupply a radiator circuit. The unit regulatesthe flow temperature of the heating mediumto a constant value (fixed value control) by

adding some of the return flow water of thecollector with a temperature controller withcontact sensor and a three-way valve.

Control range 20-50°CMax. operating temperature 50°CMax. operating pressure 6 barkvs value 4.0

The medium in the heating circuits of thesurface heating system is circulated by anelectronically controlled pump. To protectthe surface heating against overheating, forinstance in case of failure of the temperaturecontroller, the control unit is equipped with amodule which switches the pump off.

2 The advantage of the control unit“Regufloor H” is the facility to integrate

the flow tem-perature control of a surfaceheating into the heating circuit of a radiatorsystem. The illustration displays theconnection to the supply and return of theradiator system.

3 Flow temperature control can be carriedout directly at the heating generator by usingthe Oventrop boiler connection system“Regumat F-130”. Flow temperature controlis carried out by a temperature controllerwith immersion sensor and a three-wayvalve.By using this solution, the whole circuit ofa heating system can be operated with theflow temperature adapted to the surfaceheating.

1

2

3

Page 37: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 37/108

Page 38: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 38/10838

Flow temperature control of surface heating systemsControl unit “Regufloor HX“ with system separation

Years of experience have shown that un-favourable conditions in surface heatingsystems with plastic pipes may lead to cor-rosion problems caused by a penetration of

oxygen.In pure radiator systems, such corrosionproblems normally do not entail problemsas they may deposit in a number of sta-bilization zones.

In surface and especially underfloor heatingsystems, such deposits could impair theflow behaviour in the underfloor circuit. Mal-functions or even a breakdown of the circuitcould be a result.

1 The heat exchanger of the control unit“Regufloor HX” divides the system into aprimary and secondary circuit. The primarycircuit is the heating system and the secon-dary circuit is the surface heating circuit.This way, surface heating circuits with pipes

without oxygen barrier can be connected.These can be found in old installations or,system related, in new installations. Due tothe separation, a penetration of oxygen fromthe surface heating circuit into the boilercircuit is avoided. The other way round, apenetration of possible corrosion productsfrom the boiler circuit into the surface heat-ing circuit and thus a silting-up of the pipesis also avoided.

The regulating valve on the primary sideserves to control the set flow temperature.The temperature is detected with the help ofan immersion sensor on the secondary side.

The Grundfos pump “ALPHA” electronicallycontrols the pump output according to the

current heating water demand. Due to itsbronze body, the pump is corrosion resist-ant.

2 Control unit “Regufloor HX” for flow tem-perature control in surface heating systemsand for the separation of heating circuitsinto a primary and a secondary circuit incombination with the stainless steel dis-tributors/collectors, item no. 140 43 and140 45 consisting of:

Connection fittings, regulating valve, tem-perature controller with immersion sensor,heat exchanger, pressure gauge, dia-phragm safety valve, diaphragm expansiontank, electronically controlled pump.Installation is carried out on the left handside of the distributor/collector.

3 Installation exampleControl unit “Regufloor HX” with stainlesssteel distributor/collector in a surface-mounted cabinet.

1

2

3

Page 39: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 39/10839

“Cofloor” system extension for surface coolingControl unit “Regufloor HC” for

alternate operation of heating and coolingfor all laying systems

The systems “Base mat”, “Tacker”, “Dry-build” and “Clamping rail” are also suit-able to generate a comfortable roomtemperature on warmer days of the year,

when cooling water rather than heatingwater is fed through the pipework. Theterm “thermal comfort” for room coolingis explained further in DIN 1946 part 2. Itis also described as soft or quiet cooling.This cooling system is not accompanied bydraughts, high air movements, dust gen-eration or high noise levels typical of theclassic air cooling methods. In addition, theenergy exchange between humans and acooling surface is through radiation, whichis similar to the thermal balance of humanbeings.

1 If the system is operated alternately withheating or cooling water, then the permit-ted flow temperature must be checkedfor the surface heating as well as for the

surface cooling operation. Oventrop offersthe control unit “Regufloor HC” for thispurpose, which will keep the temperatureof the medium at a constant set value evenduring cooling operation by mixing somereturn flow water. The three-way valve isoperated here by an electromotive actua-tor 24 V (0-10 V) which receives its signalsfor heating and cooling from an electronicroom thermostat.

2 The flow temperature regulating set foroutside temperature guided heating andcooling via the corresponding surface heat-ing and cooling systems enables an auto-matic changeover from heating to coolingfor each application.

Flow temperature regulating set consistingof:Climate controller heating/coolingOutdoor sensorFlow temperature sensorRoom humidity measuring transducerMemory stickElectrothermal actuatorElectromotive actuatorElectric sensor attached to pipe

3 The controller heating/cooling is designedfor a universal application in heating andcooling systems, e.g. for flow temperaturecontrol in surface heating and cooling sys-tems. With integrated measuring, controland timed function via two PI controllersand preset parameters for an easy initial

operation. The remote control can be usedfor certain applications (remote control ofthe operating mode, correction of the nomi-nal values and setting of the clock).

4 The room humidity measuring transducercalculates the dew point of the air humidity.In connection with the controller heating/ cooling, it avoids condensation of the pipe-work and chilled surfaces.

1

2

4

3

Page 40: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 40/10840

“Cofloor” system extension for surface coolingHeating surface regulation for heating and cooling

Example of surface heating and cooling system

Even in surface cooling systems, the En-ergy Saving Directive calls for automaticdevices allowing an individual room tem-perature control. For this purpose, the

actuators mounted on the stainless steeldistributors/collectors receive their signalsfrom electronic room thermostats which aresuitable for switching over from heating tocooling operation.

1 The changeover from heating to cooling iscarried out via the controller heating/cool-ing. It is, amongst others, connected to theoutdoor sensor, the flow temperature sen-sor as well as the room humidity measuringtransducer. The required room temperatureis calculated with the help of the measuredvalues of these system components and iscontrolled via the electromotive actuator.The controller heating/cooling also trans-mits the operating mode “changeover fromheating or cooling” to the electrothermal

actuator for the integration of the heating orcooling generator.

The switch-over signal is also transmittedto the connection system and to the corres-ponding room thermostats. Furthermore, adew point control can be used to protectthe chilled surfaces from condensation.

2 The room thermostat heating/cooling isused for individual room temperature con-trol. It has one entry for the operating mode“changeover from heating or cooling”.

3 The connection system is mounted in thecabinet of the surface heating/cooling andserves the distribution of electric signalsand the power supply of the room thermo-stats and actuators.

1

2 3

Outdoor sensor1153051

Connection system in the underfloorheating distributor/collector1152045230 VAC6 channels Heating/coolingController –

Heating/cooling1153041

ConversionvalveHeating/cooling

C/O

N/RContact sensor1152050

Room humiditymeasuringtransducer1141960

Room thermostatHeating/cooling1152063

Thermalactuator1012485

Dew pointcontrol1141951

SwitchDew pointactivation

Room thermostatHeating/cooling1152063

Temperature

Humidity

Room thermostatHeating/cooling1152063

Room thermostatHeating/cooling1162063

Underfloor heatingdistributor/collector

Living room

Bedroom

Children’s room

Bathroom

Page 41: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 41/10841

Heating cicuit regulation of surface heating systems Actuators and room thermostats

Wireless controls

3 4

1 2

5

7

6

The Energy Saving Directive calls for a cen-tral flow temperature control of the heatingmedium (e.g. via the control unit “Regu-floor”) and for an individual selfacting room

temperature control e.g. with room thermo-stats and actuators.

Such regulating systems even out any tem-perature differences (e.g. short opening ofa window).

The Oventrop room thermostats and actua-tors fulfil these requirements. Wired andwireless devices are available for this pur-pose. The wired items are regulating com-ponents which work as two point (opened/ closed) or proportional (0-10 V) actuators.

1 Room thermostat or room thermostat-clock 230 V or 24 V with thermal actuator230 V or 24 V for room temperature controlvia the individual heating circuits. By usingthe room thermostat-clock, time controlled

temperature changes can be set.2 Distributor/collector “Multidis SF” inside acabinet with mounted electrothermal actua-tors. The wired connection to the roomthermostats is made via a plug-in rail whichis situated above the distributor/collector.

3,4 The wireless individual room tempera-ture control is carried out with a roomthermostat or a room thermostat-clock withwireless transmitter and the 4 or 6 channelreceiver. The two point actuators housed inthe cabinet (see illustr. 3) are connected tothe receiver. Apart from being suitable fornew buildings, existing buildings can alsobe upgraded with the wireless temperaturecontrol.

It is also possible to switch from heating tocooling operation.

5,6 For a wired individual room tempera-ture control, Oventrop offers proportionalactuators (0-10 V) which work with a 24 Vsupply voltage. The nominal value range ofthe electronic room thermostat can be lim-ited by use of the hidden limiting elements.The proportional actuator has the facility toreverse the actuation. This feature isnecessary for surface cooling.

7 Wireless receiver with time switch for 8channels. Application in connection withdistributors/collectors with actuators.8-channel time switch for the timed controlof up to 8 independent zones. Program-ming of the time switch and adaptation of

the transmitters is possible with removedcover.

Page 42: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 42/10842

 Accessories for stainless steel distributors/collectorsDouble regulating and commissioning valves for hydronic balancing

Heat meter connection set

2

If the room temperature in partial areas ofthe heating system is reduced, it must beensured that the other areas are not under-or oversupplied. This condition is governed

by the pressure drops in the pipe systemand the installed valves and can only bedetermined by a heat demand and pipe-work calculation. Oventrop offers relevantcalculation programmes which amongstother, will deliver the settings of the valvesfor hydronic balancing not only for theregulation of mass flow to the stainlesssteel distributors/collectors but also of theindividual heating circuits connected to thestainless steel distributors/collectors.

1 Example of a two pipe heating systemwith surface heating areas and radiatorsconnected to the risers. Balancing of themass flow to every stainless steel distribu-tor/collector with a double regulating valve“Hycocon VTZ”.

2 The “Hycocon VTZ” is a double regulatingand commissioning valve for the manualhydronic balance between several dis-tributors/collectors or risers. The infinitelyadjustable presetting is lead sealable andlockable. Available with female or malethread. The balanced mass flow can easilybe controlled with the help of the flow-meter “OV-DMC 2”.

3 If it is required to measure the heat con-sumption of separate distributor circuits,for instance of separate dwellings, it is pos-sible to install a heat meter connection setin front of the corresponding distributor/ collector. These are offered by Oventroptogether with the double regulating andcommissioning valves “Hycocon VTZ”. Forthe connection of the supply and returnpipe, the connection set is available inangle or straight pattern. The connectionset is suitable for heat meters with a lengthof 110 mm (G 3/4 male thread) and 130 mm(G 1 male thread).

4, 5 Depending on the space available, the“Hycocon VTZ” allows various installationpositions, for instance turning the heatmeter by 90° if the depth is not sufficient.

3

4 5

1

“Hydrocontrol ATR”

“Hydromat DTR”

Illustration:

Radiator and surfaceheating combination of a lowtemperature heating systemwith a max. flow temperatureof 55 °C.

“Hycocon VTZ”

Page 43: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 43/10843

 Accessories for stainless steel distributors/collectorsDifferential pressure regulators for hydronic balancing

Heat meter connection set

2

In addition to the manual hydronic balan-cing of the distributors/collectors by usingthe double regulating and commission-ing valves, a hydronic balance during low

demand periods can also be achievedwith the help of the automatic differentialpressure regulators “Hycocon DTZ”. Thisensures that the valves of the individualheating circuits are protected from unac-ceptably high differential pressure.

1 Example of a two pipe heating systemwith radiators and surface heating areasconnected to the risers. A differential pres-sure regulator “Hycocon DTZ” is installedin front of every surface heating area. Theregulator has to be set to a nominal valueto be determined (e.g. 150 mbar). The regu-lator will maintain a constant differentialpressure between supply and return withina necessary proportional band.

2 The installation of an automatic differen-tial pressure regulator “Hycocon DTZ”allows that the distributor units can operateindependently. The permissible differentialpressure between supply and return can beset and locked at the “Hycocon DTZ”. A change in the system pressure has there-fore no influence on the heating circuits ofthe distributor units of the surface heating. A manual balance is not required.

3,4 To install the differential pressure regu-lator together with a heat meter connectionset, Oventrop offers connection sets inangle or straight patterns (installation sizes110 mm and 130 mm).

3

4

1

“Hydrocontrol ATR”

“Hydromat DTR”

Illustration:

Radiator and surfaceheating combination of a lowtemperature heating systemwith a max. flow temperatureof 55 °C.

“Hycocon DTZ”

Page 44: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 44/10844

Dwelling station“Regudis W-HTF”Integration of surface heating and cooling

The station “Regudis W-HTF” which ismounted on a fixing sheet is a completelypre-assembled and leak tested unit withconstant or variable temperature circuit.

The station does not only supply a dwellingwith hot water for the radiators or under-floor heating, but also with potable water.

1 Station “Regudis W-HTF” as completemodel for a dwelling with underfloor heating,consisting of:- “Regudis W-HTF”  dwelling station, item no. 134 11 40- Connecting block  (8 control zones) for room thermostats

and actuators, item no. 140 10 81- Electrothermal actuator  (2 point), closed with current off, 230 V,  item no. 101 28 15- Cabinet – extended model  for the direct connection of the dwelling

station and the underfloor heating

distributor/collector  Dimensions:  Width 700 mm  Height 1210 – 1335 mm  Depth 115 – 180 mm  Steel, galvanized, frame and door white

lacquered, removable screen,  item no. 134 11 75- Derivative temperature control set  to maintain the flow temperature in the

“Regudis W-HTF” station to guarantee aquick supply of hot potable water outsidethe heating period,

  item no. 134 11 90,- Ball valve connector block  7 ball valves mounted in a bracket for the

isolation of all connections of the“Regudis W-HTF” station.

  Connections to the pipework:  Rp 3/4 female,  item no. 134 11 80- Connection set stainless steel dis-  tributor/collector  for the connection of the dwelling station

“Regudis W-HTF” to the stainless steeldistributor/collector “Multidis SF”,

  item no. 134 11 87- “Multidis SF”  8-fold stainless steel distributor/collector

for surface heating systems with inte-  grated flow measuring and regulating

devices,  item no. 140 34 58

2 System illustration

1

2

Page 45: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 45/108

Page 46: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 46/108

Page 47: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 47/10847

“Unibox vario”“Unibox E vario”

“Unibox vario”Installation set (basic model) for tempera-ture limitation of heating surfaces withreturn temperature limiter.

Temperature range: 10-40°C factory setting(return temperature), may be increased to50°C by cancelling the limitation (40°C).Room temperature: depending on the usedcontrol.

The basic model can be converted to:

“Unibox vario” with thermostat withremote control “Uni FH”The control is mounted on the vertical valveconnection inside the “Unibox”. The capil-lary towards the room temperature sensorcan be led downwards out of the “Unibox”,e.g. through an empty pipe.

or

“Unibox vario” with electric room ther-mostat and actuatorThe actuator is mounted on the vertical con-nection inside the “Unibox” (when using anelectromotive actuator, the stem extension,item no. 102 26 98, is additionally required).The connecting cable towards the roomthermostat can be led downwards out of the“Unibox”. Laying through an empty pipe isadvantageous.

(  Attention: In case of installation in thebathroom, the regulations for electricinstallations in humid areas have to be ob-served.)

“Unibox E vario”Installation set (basic model) for tempera-ture limitation of heating surfaces withreturn temperature limiter (hidden).

Temperature range:20-40°C (return temperature)Room temperature: depending on the usedcontrol.

The basic model can be converted to:

“Unibox E vario” with thermostat withremote control “Uni FH”The control is mounted on the vertical valveconnection inside the “Unibox”. The capil-

lary towards the room temperature sensorcan be led downwards out of the “Unibox”,e.g. through an empty pipe.

or

“Unibox E vario” with electric roomthermostat and actuatorThe actuator is mounted on the verticalconnection inside the “Unibox”. The con-necting cable can be led towards the roomthermostat through a hole to be drilledon the outer wall of the “Unibox”. Layingthrough an empty pipe is advantageous.

(  Attention: In case of installation in thebathroom, the regulations for electricinstallations in humid areas have to be ob-

served.)

Surface heating

   S  u  p  p   l  y

   R  e   t  u  r  n

Individual roomtemperature con-trol with thermostatwith remote control“Uni FH“

Surface heating

   S  u  p  p   l  y

   R  e   t  u  r  n

Individual roomtemperature con-

trol with electricroom thermostatand acuator

Surface heating

   S  u  p  p   l  y

   R  e   t  u  r  n

Individual roomtemperature con-trol with thermostatwith remote control

“Uni FH“

Surface heating

   S  u  p  p   l  y

   R  e   t  u  r  n

Individual roomtemperature con-trol with thermostatwith remote control“Uni FH“

Page 48: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 48/10848

 ApplicationInstallation and assembly

 Appl ication:The different models of the “Unibox” aresuitable for the operation of a surface heat-ing system in rooms with a heating surface

up to 20 m². They are designed for the con-nection of one heating circuit. When usingpipes with an inner diameter of 12 mm, alength of 100 m must not be exceeded.It is to be observed that the supply andreturn pipe are laid alternately side by side(see e.g. the spiral laying in the installationsketches pages 2, 3 and 4). A constantheating of the floor is thus guaranteed.

The “Unibox TSH” / “Unibox T” /“Unibox E T” / “Unibox E TC” allows thecontrol of the room temperature via the sur-face heating system. It is used in combina-tion with a low temperature heating systemwith a maximum flow temperature of 55°C.

The “Unibox RTL” / “Unibox E RTL” allows the temperature limitation of heatingsurfaces with return temperature limiter.The room temperature is still controlled viathe radiator. Installation is carried out incombination with a radiator heating with amaximum flow temperature of 70°C.

The “Unibox plus” / “Unibox E plus” / “Unibox vario” / “Unibox E vario” allowsthe individual room temperature controlwith thermostatic valve and the tem-perature limitation of heating surfaces withreturn temperature limiter. As for the “Unibox RTL”, installation iscarried out in combination with a radiatorheating with a maximum flow temperatureof 70°C.

Installation and assembly:

For a simple installation of the pipes in thewall, Oventrop offers a pipe conduit unitsized to the depth of the “Unibox”/ “Unibox E”.Installation may be carried out easily.The pipe conduit unit and the installationset are fixed in the wall (see illustr. 1 instal-lation sketch). The heating pipes are laidaccording to the installation instructions.

Important:The “Unibox” always has to be installedbehind the surface heating circuit, i.e.in the return pipe. The direction of flowhas to be observed (illustr. 2).

For the connection to the valve, Oventropoffers suitable compression fittings. The

pipe conduit unit is closed and plastered.The fixing channel is closed with the coverplate. Control is carried out via the thermo-stat which is easily accessible. Care shouldbe taken that the thermostat is not influ-enced by other heat sources.

- Do not install near other heat sources,e.g. additional radiators (illustr. 3).

- Protect thermostat from direct sunlight(illustr. 4).

- Do not install at a location exposed todraught.

Example of installation for two surfaceheating circuits:In case of heating surfaces exceeding 20m²and a pipe length of more than 100 mper heating circuit, it is recommended to

connect two heating circuits of the samesize to the “Unibox” (illustr. 5). The installa-tion is then carried out by use of the Oven-trop “h” fitting, item no. 102 87 50 and thefitting item no. 101 63 04 or the Duo con-nection piece.

“Unibox E plus”1 “Unibox plus”

Wall box unit

Thermostat “Uni RTLH”

Prsettable valve with

thermostat “Uni LH”

Thermostat

Pipe conduit unit

 Valve with presettableinsert and integrated

return temperature limiter

2

3

5

4

Surface heating

   S  u  p  p   l  y

   R  e   t  u  r  n

Surface heating

  S  u  p  p   l  y

   R  e  t  u  r  n

Correct Wrong

Wrong Wrong

Page 49: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 49/10849

CabinetsInstallation instructions/Dimension chart

Recommendations for cabinets:

 Cabinet item no. 140 11 51, no. 1, inner width: 560 mm Cabinet item no. 140 11 53, no. 3, inner width: 900 mm

 Cabinet item no. 140 11 52, no. 2, inner width: 700 mm Cabinet item no. 140 11 54, no. 4, inner width: 1200 mm

 

L1 L2 L2 L3 L4 L5 L5

  Number Length with Length with Length with Length with Length with Length with

Item of Length ball valve ball valve heat meter heat meter control unit control unit

no. heating DN 20 DN 25 connection set  connection set  and ball and ball  circuits Angle pattern Straight pattern valve valve  DN 20 DN 25

  140 43 52 2 190 mm 245 mm 270 mm 377 mm 544 mm 560 mm 585 mm

140 43 53 3 240 mm 295 mm 320 mm 427 mm 594 mm 610 mm 635 mm

  140 43 54 4 290 mm 345 mm 370 mm 477 mm 644 mm 660 mm 685 mm

  140 43 55 5 340 mm 395 mm 420 mm 527 mm 694 mm 710 mm 735 mm

  140 43 56 6 390 mm 445 mm 470 mm 577 mm 744 mm 760 mm 785 mm

  140 43 57 7 440 mm 495 mm 520 mm 627 mm 794 mm 810 mm 835 mm

140 43 58 8 490 mm 545 mm 570 mm 677 mm 844 mm 860 mm 885 mm

140 43 59 9 540 mm 595 mm 620 mm 727 mm 894 mm 910 mm 935 mm

  140 43 60 10 590 mm 645 mm 670 mm 777 mm 944 mm 960 mm 985 mm

  140 43 61 11 640 mm 695 mm 720 mm 827 mm 994 mm 1.010 mm 1.035 mm

  140 43 62 12 690 mm 745 mm 770 mm 877 mm 1.044 mm 1.060 mm 1.085 mm

G 3/4

L 2

L 1

50

  m  a  x .   9   1

   2   0   0

G 1

G 1

L 3

138 L 1

53 101

G 3/4

   1   3   0  x   G   1

   1   1   0  x   G   3   /   4

   5   0

   1   1   4

   2   0   0

   8   0

50

Page 50: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 50/10850

Recommendation for surface-mounted cabinets:

 Cabinet item no. 140 11 71, no. 1, inner width: 600 mm Cabinet item no. 140 11 73, no. 3, inner width: 1000 mm

 Cabinet item no. 140 11 72, no. 2, inner width: 750 mm Cabinet item no. 140 11 74, no. 4, inner width: 1250 mm

Surface-mouted cabinetsInstallation instructions/Dimension charts

Number

of heating

circuits

Item

no.

L1

Length

L2

Length

with angle

pattern set

L3

Length

with heat meter

connection set

 Angle pattern

L4

Length with

control unit

and angle

pattern set

  2

  3

  4

  5

  6

  7

  8

  9

10

11

12

140 43 52

140 43 53

140 43 54

140 43 55

140 43 56

140 43 57

140 43 58

140 43 59

140 43 60

140 43 61

140 43 62

L 2

104 L 1

53

G 3/4

67

   2   0   0

   1   1   5

   2   0   0

50

190

240

290

340

390

440

490

540

590

640

690

320

370

420

470

520

570

620

670

720

770

820

377

427

477

527

577

627

677

727

777

827

877

  636

  686

  736

  786

  836

  886

  936

  986

1036

1086

1136

  m  a  x .

   9   1

L 3

138 L 1

53 101

G 3/4

   1   3   0  x   G   1

   1   1   0  x   G   3   /   4

   5   0

   1   1   4

   2   0   0

   8   0

50

Page 51: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 51/108

Page 52: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 52/10852

Sample form“Cofloor” material list

 Red: Recommended laying distances in the

Laying Required pipe Residential area Bathroomdistance per m2 of Residential area Fringe area

LD heating surface 14 x 2 mm 16 x 2 mm 14 x 2 mm 16 x 2 mm 14 x 2 mm 16 x 2 mm

50 mm 20 m / m2

  100 mm 10 m / m2

  150 mm 6.7 m / m2

200 mm 5 m / m2

  250 mm 4 m / m2

  300 mm 3.3 m / m2

The minimum bending radii of the PE-Xc pipes “Copex”, the PE-RT pipes “Copert” and “Copipe HK”-pipes must be observed. If necessa-ry, the laying distance has to be increased where return loops are laid.

 Article

Base mat NP 35

Edge isolating strip

Item no.

140 22 10

140 20 90

 per m2

  1.00

  0.04

Laying distance 5 cm “Copipe” pipe 16 x 2 mm 150 01 55 20.00

Laying distance 10 cm “Copipe” pipe 16 x 2 mm 150 01 55 10.00

Laying distance 15 cm “Copipe” pipe 16 x 2 mm 150 01 55 6.67

Laying distance 20 cm “Copipe” pipe 16 x 2 mm 150 01 55 5.00

Laying distance 25 cm “Copipe” pipe 16 x 2 mm 150 01 55 4.00

Laying distance 30 cm “Copipe” pipe 16 x 2 mm 150 01 55 3.33

Material list per square meter

(also applies for pipes 14 x 2 mm)

Base mat system “Cofloor”

Composition pipe “Copipe”

Plastic pipe “Copex”

 Article

Base mat NP 35

Edge isolating strip

Item no.

140 22 10

140 20 90

per m2

  1.00

  0.04

Laying distance 5 cm “Copex” pipe 16 x 2 mm 140 01 51 20.00

Laying distance 10 cm “Copex” pipe 16 x 2 mm 140 01 51 10.00

Laying distance 15 cm “Copex” pipe 16 x 2 mm 140 01 51 6.67Laying distance 20 cm “Copex” pipe 16 x 2 mm 140 01 51 5.00

Laying distance 25 cm “Copex” pipe 16 x 2 mm 140 01 51 4.00

Laying distance 30 cm “Copex” pipe 16 x 2 mm 140 01 51 3.33

 Accessories

Expansion strip

Protection pipe

Round profile PE foam

Pipe guiding elbow

Marker point for screed measurement

Coil unwinder

Compression fitting

Floor level distributor/collector 5-fold

Item no.

140 20 91

150 11 84

140 20 92

140 90 85

140 90 90

140 20 96

150 79 75

140 43 55

Page 53: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 53/108

Page 54: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 54/10854

Sample formPressure test record of the Oventrop surface heating

and cooling system “Cofloor” according to EN 1264-4

Client: __________________________________________________________________________________________________

Building/ project: __________________________________________________________________________________________________

Stage of construction/ 

floor/dwelling: __________________________________________________________________________________________

Section of the system: __________________________________________________________________________________

Requirements

Before laying the screed, plaster or levelling compound, tightness of the heating/cooling circuits of the surface heating/coo-

ling system is tested by carrying out a water pressure test. Contrary to the VOB C (DIN 18 380 standard), the test pressuremust be at least for 4 bar and not more than 6 bar. This pressure must be maintained throughout the laying of the screed/ 

plaster*.

The test pressure is carried out section by section after having flushed the individual heating circuits. It must be ensured

that the succeeding sections of the system are protected from excess pressure (if necessary, by main isolation device in

front of the distributor/collector).

 Alternatively, the tightness can also be tested by carrying out a pressure test with compressed air. Here, the maximum test

pressure amounts to 3 bar.

Documentation

Maximum permissible operating pressure _______________________________ bar

Test pressure _______________________________ bar

Test cycle _______________________________ h

Tightness was checked and no lasting deformation was detected on any component.

Confirmation

_______________________________ _______________________________ _______________________________

Place/date Place/date Place/date

_______________________________ _______________________________ _______________________________Builder/Client Building supervisor/Architect InstallerStamp/signature Stamp/signature Stamp/signature

*Procedure may be different for wall and ceiling heating systems.

Page 55: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 55/108

Page 56: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 56/108

Page 57: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 57/108

Page 58: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 58/108

Page 59: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 59/108

Page 60: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 60/108

...................................................................................................................... 96

................................................................................................................................................................... 96

................................................................................................................................................ 97

.................................................................................................................................... 98

....................................................................................................................................................................... 98

.................................................................................99 –100

................................................................................................................... 100

..................................................................................................................... 101

......................................................................................................................................... 102

............................................................................................................................................. 102

.................................................................................................................................................... 102

....................................................................................................................................................... 102

...................................................................................................................................................................... 102

......................................................................................................................................................................... 102

................................................................................................................ 103

..................................................................................................................................................................... 104

......................................................................................................... 105

........................................................................................................................................... 105

......................................................................................................................................... 105

.......................................................................................................... 106

........................................................................................................................................... 106

......................................................................................................................................... 106

......................................................................................................................................................... 107

60

Illustrated list – “Cofloor” surface heating and cooling systems –Extract from the catalogue 2013

Page 61: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 61/10861

System illustration: “Unidis” Surface heating with return collector “Floorbox MH” and fixing channel

1 “Floorbox MH” Return collector

2 “Unibox EBV”

3 Fixing channel

4 “Copipe” Composition pipe

“Copex” PE-Xc pipe

“Copert” PE-RT pipe

System illustration: “Unidis” Surface heating with “Floorbox UH” and “Unibox EBV”

1 “Floorbox UH”

2 “Unibox EBV”

3 “Regumat F-130/180” Fixed value control unit

4 “Copipe” Composition pipe

“Copex” PE-Xc pipe“Copert” PE-RT pipe

1

2

34

2

Supply

“Unibox E BV” “Unibox E BV”

Return

Surface heating Surface heating

1

2

3

4

2

 

System summary

Page 62: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 62/10862

System summary

Page 63: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 63/10863

“Unidis” Surface heating systemwith local flow distribution

"Unibox EBV"

Combination room temperature control

and presettable bypass

Depth: 57 mm

 Application:

For installations with flow temperatures

suitable for surface heating systems

according to DIN EN 1264.

Installation set consisting of:

Wall box unit with thermostatic valve with

integrated bypass stem and regulating insert,

working without auxiliary energy. Venting and

flushing valve, valve insulation and cover plate,

thermostat with '0' setting, valve connection

G ¾ for Oventrop compression fittings. For the

division of the flow rate into a permanent partial

flow adjustable via the bypass and a

thermostatically controlled partial flow. Setting

of a minimum flow rate via the bypass

guaranteeing a basic heat load of the

underfloor heating system (no cooling down).

0.75 0.28 0.52 102 26 62

I-57-I "Unibox RLA"

Combination isolating and regulating function

Installation set for the isolation of surface

heating circuits in combination with

"Uniboxes".

Page 2.18.

I-57-I "Unibox E T"

Room temperature control

Installation set consisting of:

Wall box unit with presettable thermostatic

valve, venting and flushing valve.

Page 2.18.

I-57-I "Unibox T"

Room temperature control

with thermostat "Uni LH"

Installation set consisting of:

Wall box unit with presettable thermostatic

valve, integrated deaeration and cover plate,

with thermostat "Uni LH".

Page 2.18.

"Unibox E BVC"

Combination room temperature control

with additional cooling position and presettable bypass

Installation set consisting of:

Wall box unit with thermostatic valve and

integrated bypass stem and regulating insert.

Page 2.21.

I-57-I "Unibox ETC"

Combinatioon room temperature control

with additional cooling function

Installation set consisting of:

Wall box unit with presettable thermostatic

valve, venting and flushing valve.

Page 2.21.

 

 Article kvs

kv

at 1K

P-dev.

kv

at 2K

P-dev.

 Article-No. Hint

Page 68

Page 68

Page 68

Page 70

Page 71

E TC"

Page 64: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 64/10864

"Floorbox MH" Return collector

for "Unidis" surface heating

Central consolidation of heating circuit returns

in the "Unibox" system, lateral riser connection

The "Floorbox MH" is used for central

consolidation of the individual heating circuit

returns together with "Uniboxes".

(riser connection from the right and left hand

side)

Installation set consisting of:

Supply:

– Ball valve with temperature sensor

connection

– 2-fold distributor for the connection of two

supply pipes to the boxes

Return:

– Two return collectors (with flow measuring

and regulating inserts)

– Fill and drain cock

– Vent plug

– "Hycocon VTZ" double regulating and

commissioning valve

– Meter stool piece

– Ball valve

Models:

with one return collector (6-fold) 102 70 53

for 6 circuits

with two return collectors (4-fold each) 102 70 54

for 8 circuits

with two return collectors (5-fold each) 102 70 55

for 10 circuits

with two return collectors (6-fold each) 102 70 56

for 12 circuits

 

 Article Article-No. Hint

"Floorbox U"

Connection without distributor/collector

for surface heating systems

The "Floorbox" serves to connect each

dwelling to the surface heating system together

with the installation sets "Unibox".

Installation set consisting of:

Supply:

- Ball valve G 1 with temperature sensor

  connection

Return:

- "Hycocon VTZ" double regulating

  and commissioning valve

- Meter stool piece

- Ball valve with coupling

- Venting and flushing valve

- Flat seals

Depth: 110 - 145 mm

Width: 400 mm

Height: 350 mm

System illustration: page 2.06

lateral connection

"Floorbox UH" lateral connection 102 26 68

lower connection

"Floorbox UV" lower connection 102 26 69

 

“Unidis” Surface heating systemwith local flow distribution

page 61

Page 65: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 65/10865

Fixing channel For heavyweight and lightweight walls, made of

galvanised steel sheet for pipework installation

out of the ground into the wall to the "Unibox".

 An additionally required installation set of the

"Unibox" range has to be ordered separately

and has to be installed in the fixing channel.

 Assembly without screws or rivets. Adaptation

to the installation height via an adjustable

extension. The adaptation of the installation

depth for heavyweight walls is carried out by

use of elbows. The fixing channel of lightweight

walls is screwed directly onto the profiles.

 Additional cut-outs in the reverse side of the

fixing channel allow the connection of the

"Unibox" even from an adjoining room.

The "Unibox" has to be mounted in the fixing

channel only shortly before plastering

commences.

 An exact installation of the "Unibox" is

guaranteed by the variable installation options.

The connection openings (rated break points)

of the fixing channel allow the connection of all

remote controls, remote sensors (mechanical

or electric).

Height: 440 - 490 mm (extendible)

Width: 160 mm

for "Unibox", depth: 57 mm 102 26 53

Sequence of installation (summary):

1 Adjust depth and height, alignwith wall recess

2 Place fixing channel into the

wall

3 Mount “Unibox” and both

supply connection pieces

4 Mount protection cover of the

“Unibox” and of the fixing channel

5 Carry out wall plastering 6 Lay supply pipe from the heat

generator on the bare floor and

insulate

7 Lay edge isolating strip and

system board

8 Lay heating circuit, connect to

supply connection piece and feed

return to return collector

 

 Article Article-No. Hint

“Unidis” Surface heating systemwith local flow distribution

Page 66: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 66/10866

Fixing channel with isolating facility 

with cover plate and thermostat with remote control

For heavyweight and lightweight walls, made of

galvanised steel sheet for pipework installation

out of the ground into the wall to the "Unibox".

 An addtional installation set of the "Unibox"

programme has to be ordered separately and

has to be fit into the fixing channel.

For this purpose, the "Unibox E BV" is available

without cover plate (see item no. 102 26 76).

For the connection without distributors/ 

collectors and the room to room isolation of

surface heating circuits.

Isolating facility consisting of:

Isolating valve, venting and flushing valve,

valve connection G ¾ for Oventrop

compression fittings.

 Assembly without screws or rivets. Adaptation

to the installation height via an adjustable

extension. The adaptation of the installation

depth for heavyweight walls is carried out by

use of elbows. The fixing channel of lightweight

walls is screwed directly onto the profiles.

 Additional cut-outs in the reverse side of the

fixing channel allow the connection of the

"Unibox" even from an adjoining room.

The "Unibox" has to be mounted in the fixing

channel only shortly before plastering

commences. A special cover plate for the

"Unibox" is supplied with the fixing channel.

 An exact installation of the "Unibox" isguaranteed by the variable installation options.

The connection openings (rated break points)

of the fixing channel allow the connection of all

remote controls, remote sensors (mechanical

or electric).

Height: 440 - 490 mm (extendible)

Width: 160 mm

for "Unibox", depth: 57 mm 102 26 54*

"Unibox E BV"

without cover plate and thermostat

 Application:

For installations with flow temperatures

suitable for surface heating systems according

to DIN EN 1264.

Installation set for use in the fixing channel with

heating circuit isolation (item no. 102 26 54).

Installation set consisting of:

Wall box unit without cover plate, thermostatic

valve with integrated bypass stem and

regulating insert, working without auxiliary

energy. Venting and flushing valve, valve

insulation, valve connection G ¾ for Oventrop

compression fittings.

For the division of the flow rate into a

permanent partial flow adjustable via the

bypass and a thermostatically controlled partial

flow. Setting of a minimum flow via the bypass

guaranteeing a basic heat load of the

underfloor heating (no cooling down).

Combination room temperature control 102 26 76*and presettable bypass

 

 Article Article-No. Hint

 

“Unidis” Surface heating systemwith local flow distribution

Page 67: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 67/10867

Pipe connection press T-piece Height: 321 mm

Stainless steel pipe: Ø 15 x 1.0 mm

For a simple connection of the "Unibox" to the

supply pipe or the heating loop via the fixing

channel.

The pipes have to be shortened according to

the required installation height.

Pipe made of stainless steel, fitting made of brassfor composition pipe "Copipe",

with "Ofix CEP" - Snap & Seal -

compression fitting for male thread G ¾

according to DIN V 3838 (cone "Euro")

16 x 2.0 mm 151 51 53*20 x 2.5 mm 151 51 56*

Pipe connection press elbow

Pipe made of stainless steel, fitting made of brass

for composition pipe "Copipe",

with "Ofix CEP" - Snap & Seal -

compression fitting for male thread G ¾

according to DIN V 3838 (cone "Euro")

16 x 2.0 mm 151 53 53*20 x 2.5 mm 151 53 56*

 

 Article Article-No. Hint

 

Heating circuit level

3

Heating

circuit level

Supply level   S  u  p

  p  l  y   l  e  v  e

  l

   H  e  a   t   i  n

  g 

  c   i  r  c  u   i   t    l

  e  v  e   l

Heating circuit

level

Supply level

Heating circuit level

 

“Unidis” Surface heating systemwith local flow distribution

Page 68: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 68/10868

"Unibox E BV"

Combination room temperature control

and presettable bypass

Depth: 57 mm

white model

"Unibox E" (exclusive model) and "Unibox"

 individual room temperature control for

surface heating systems

 Application:

For installations with flow temperatures

suitable for surface heating systems

according to DIN EN 1264.

Installation set consisting of:

Wall box unit with thermostatic valve with

integrated bypass stem and regulating insert,

working without auxiliary energy. Venting and

flushing valve, valve insulation and cover plate,

thermostat with '0' setting, valve connection

G ¾ for Oventrop compression fittings. For the

division of the flow rate into a permanent partial

flow adjustable via the bypass and a

thermostatically controlled partial flow. Setting

of a minimum flow via the bypass guaranteeinga basic heat load of the underfloor heating (no

cooling down).

0.75 0.28 0.52 102 26 62

"Unibox RLA"

Combination isolating and regulating function

Depth: 57 mm

Installation set consisting of:

Wall box unit with isolating valve, venting and

flushing valve, closed cover plate, valve

connection G ¾ for Oventrop compression

fittings. For the isolation of surface heating

circuits in combination with the installation sets

"Unibox".

white model 102 26 63

"Unibox E T"

Room temperature control

Depth: 57 mm

Installation set consisting of:

Wall box unit with presettable thermostatic

valve, venting and flushing valve, valve

insulation and cover plate, thermostat with '0'

setting, valve connection G ¾ for Oventrop

compression fittings.

For room temperature control.

Temperature range: 7 - 28 °C

(room temperature)

Model:

white 0.75 0.28 0.52 102 26 32

chrome

plated

0.75 0.28 0.52 102 26 42

"Unibox T"

Room temperature control

with thermostat "Uni LH"

Depth: 57 mm

Installation set consisting of:

Wall box unit with presettable thermostatic

valve, integrated deaeration and cover plate,

with thermostat "Uni LH" with '0' setting, valve

connection G ¾ for Oventrop compression

fittings.

For room temperature control.

Temperature range: 7 - 28 °C

(room temperature)

The models "Unibox ET" and "Unibox T"

comply with the requirements of the Energy

Saving Directive (EnEV § 14).

Model:

white 0.90 0.32 0.65 102 26 36

chrome

plated

0.90 0.32 0.65 102 26 46

 

 Article kvs

kv

at 1K

P-dev.

kv

at 2K

P-dev.

 Article-No. Hint

“Unibox” Room temperature control

Page 69: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 69/10869

"Unibox TSH"

Room temperature control

with thermostat "Uni SH"

Depth: 57 mm

Installation set consisting of:

Wall box unit with presettable thermostatic

valve, integrated deaeration and cover plate,

with thermostat "Uni SH" with '0' setting, valve

connection G ¾ for Oventrop compression

fittings.

For room temperature control.

Temperature range: 7-28 °C

(room temperature)

The models "Unibox E T", "Unibox T" and

"Unibox TSH" comply with the requirements of

the Energy Saving Directive (EnEV § 14).

white model

0.32 0.59 0.80 102 26 12

 

 Article kvs

kv

at 1K

P-dev.

kv

at 2K

P-dev.

 Article-No. Hint

"Unibox E plus"

Combination room temperature control

and limitation of return temperature

Depth: 57 mm

"Unibox E" (exclusive model) individual

room temperature control and limitation of

return temperature for surface heating

systems

 Application:

In combination with heating systems with

radiator operation.Installation set consisting of:

Wall box unit with presettable thermostatic

valve and integrated return temperature limiter,

venting and flushing valve, valve insulation and

cover plate, thermostat with '0' setting, valve

connection G ¾ for Oventrop compression

fittings.

For the control of the room temperature and

limitation of the return temperature.

Temperature range: 7-28 °C

(room temperature)

20-40 °C (return temperature)

Good Design Award Japan

Model:

white 0.75 0.28 0.52 102 26 33chrome

plated

0.75 0.28 0.52 102 26 43

stainless

steel finish

0.75 0.28 0.52 102 26 73

 

“Unibox” Room temperature control

Page 70: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 70/10870

 

"Unibox E vario"

Basic model for limitation of

return temperature (hidden)Depth: 57 mm

Installation set consisting of:

Wall box unit with presettable thermostatic

valve and integrated return temperature limiter,venting and flushing valve and closed cover

plate, valve connection G ¾ for Oventrop

compression fittings.

For the control of the room temperature and

limitation of the return temperature.

Temperature range: 20-40 °C

(return temperature)

Room temperature depending on the used

control.

Model:

white 0.75 0.28 0.52 102 26 34

chrome

plated

0.75 0.28 0.52 102 26 44

Room temperature control is possible by mounting the following

thermostats (to be ordered separately):

– Thermostat with remote control "Uni FH"

(page 2.73)

and thermostat "Uni FHC" (page 1. 00 )

or:

– room thermostat and actuator

(page 3. 00 )

"Unibox E RTL"

Limitation of return temperature (hidden)

Depth: 57 mm

Installation set consisting of:

Wall box unit with integrated return

temperature limiter, venting and flushing valve

and closed cover plate, valve connection G ¾

for Oventrop compression fittings.

For return temperature limitation.

Temperature range: 20-40 °C

(return temperature).

The models- "Unibox E plus"

- "Unibox E vario"

comply with the requirements of the Energy

Saving Diretive (EnEV § 14).

white model 102 26 31

chrome plated model 102 26 41

Limitation of the return temperature from the outside:

page 2.22, item no. 102 26 35 / 45

"Unibox E BVC"

Combination room temperature control

with additional cooling position and presettable bypass

Depth: 57 mm

"Unibox E" (exclusive model) individual

room temperature control for surface

heating and cooling systems

 Application:For installations with flow temperatures

suitable for surface heating systems

according to DIN EN 1264.

Installation set consisting of:

Wall box unit with thermostatic valve with

integrated bypass stem and regulating insert,

working without auxiliary energy. Venting and

flushing valve, valve insulation and cover plate,

thermostat with cooling position, valve

connection G ¾ for Oventrop compression

fittings. For the division of the flow rate into a

permanent partial flow adjustable via the

bypass and a thermostatically controlled partial

flow (only in case of heating). Setting of aminimum flow via the bypass guaranteeing a

perfect operation of heat pumps and for a

basic heat load of the underfloor heating (no

cooling down).Temperature range: 7-28 °C

(room temperature)

 Additional cooling position: C (cooling

depending on the flow temperature).

white

model

0.75 0.28 0.52 102 26 67

 

“Unibox” Room temperature control

 

 Article kvs

kv

at 1K

P-dev.

kv

at 2K

P-dev.

 Article-No. Hint

Page 71: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 71/10871

 

"Unibox E TC"

Combination room temperature control

with additional cooling positionDepth: 57 mm

Installation set consisting of:

Wall box unit with presettable thermostatic

valve, venting and flushing valve, valveinsulation and cover plate, thermostat with

cooling position, valve connection G ¾ for

Oventrop compression fittings.

For room temperature control.

Temperature range: 7-28 °C

(room temperature)

 Additional cooling position: C (cooling

depending on the flow temperature).

white

model

0.75 0.28 0.52 102 26 66

 

 Article kvs

kv

at 1K

P-dev.

kv

at 2K

P-dev.

 Article-No. Hint

"Unibox plus"

Combination thermostat "Uni LH"

and thermostat "Uni RTLH"

Depth: 57 mm

„"Unibox" individual room temperature

control and limitation of return temperature

for surface heating systems.

 Application:

In combination with heating systems with

radiator operation.

Installation set consisting of:

Wall box unit with presettable thermostatic

valve and RTLH valve, venting and flushing

valve and cover plate, thermostats "Uni LH"

and "Uni RTLH" with '0' setting. Valve

connection G ¾ for Oventrop compression

fittings.

The RTLH valve insert with double disc

prevents inadvertent overheating, with frostprotection.

For the control of the room temperature and

limitation of the return temperature.

Temperature range: 7–28 °C

(room temperature)

10–40 °C factory setting (return temperature)

may be increased to 50 °C by cancelling the

limitation (40 °C) .

 Awards "Unibox Plus":

Interclima ParisTrophée du Design

Interclima ParisConcours de l’Innovation

Model:

white 0.90 0.65 102 26 37

chrome

plated

0.90 0.65 102 26 47

"Unibox vario"

Basic model for

limitation of return temperature

(with thermostat "Uni RTLH")

Depth: 57 mm

Installation set consisting of:

Wall box unit with presettable thermostatic

valve and RTLH valve, venting and flushing

valve and cover plate, thermostat "Uni RTLH"

with '0' setting, valve connection G ¾ for

Oventrop compression fittings.

The RTLH valve insert with double disc

prevents inadvertent overheating, with frost

protection.

For the control of the room temperature and

limitation of the return temperature.

Temperature range: 10–40 °C factory setting

(return temperature) may be increased to 50 °C

by cancelling the limitation (40 °C).

Room temperature depending on the used

control.

Model:

white 0.90 0.32 0.65 102 26 38

Room temperature control is possible by mounting the following

thermostats (to be ordered separately):

– Thermostat with remote control "Uni FH" (page 2.73)

and thermostat "Uni FHC" (page 1. 00 )

or

– room thermostat and actuator

(page 3. 00 ),When using an electromotive actuator, the stem extension, item no.

102 26 98, is required.

 

“Unibox” Room temperature control

Page 72: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 72/108

Page 73: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 73/10873

Conversion set "Unibox T" Position 1 - 4 are used for the conversion of a

"Unibox E RTL" to "Unibox T".

 A "Unibox E RTL" can be re-assembled by use

of the valve dismounted before and positions

5 - 7.

               5

          4

        3

          2

          1

      o      v      e      n       t      r      o      p

for "Unibox E RTL"102 26 39

consisting of:

1 Presettable thermostatic valve

2 Thermostat "Uni LH"

3 Spacer, screws

4 White cover plate

5 Wall box unit

6 Bracket

7 Protection cover plate

 Accessories

Fixing channel

for "Unibox", depth: 57 mm 102 26 52 Made of galvanised sheet steel, with covermade of gypsum plaster board.

Height: extendible between 275 and 350 mm

Width: 130 mm

for "Unibox", depth: 57 mm 102 26 53 Made of galvanised steel sheet

Height: extendible between 400 and 490 mm

Width: 160 mm

Pipe conduit unit

for "Unibox", depth: 57 mm 102 26 50 Suitable for the wall box units.

For a simple installation of the pipe into thewall. May be easily reduced to other

dimensions.

L = 1 m.

Cover plates

white model (RAL 9016) 102 26 87 For "Unibox E BV", "Unibox E BVC", "Unibox E

plus", "Unibox E T" and "Unibox E TC" with

depth 57 mm.

chrome plated model 102 26 88

white model (RAL 9016)

closed 102 26 79 For "Unibox E vario" with depth 57 mm.

white model (RAL 9016) 102 26 89 For "Unibox E RTL" with depth 57 mm.

chrome plated model 102 26 90

white model (RAL 9016) 102 26 93 For "Unibox RTL", "Unibox T", "Unibox vario"

and "Unibox plus" wall box unit with depth 57

mm.

chrome plated model 102 26 94

white model (RAL 9016) (2) 102 26 91 For "Unibox RTL", "Unibox T" and "Unibox

plus" wall box unit with depth 110 mm.

chrome plated model 102 26 92

Cover plate with thermostat with remote control

chrome plated model 102 26 97

 

 ArticlePacking

unit Article-No. Hint

“Unibox” Room temperature control

Page 74: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 74/10874

 Valve inserts

for return flow valves (100) 102 69 81  Valve insert with double disc.

Prevents inadvertent overheating,

with frost protection.

Special valve insert for reversed supply and return pipe

with 6 presetting positions

 As replacement for:

– "Multiblock T/TF"

– "Unibox ET/ETC"

– "Unibox E plus"

– "Unibox E vario"

– "Unibox E BV/ E BVC"

In case of reversed direction of flow for:

– "Unibox T"

– "Unibox plus" (connection for room

temperature control)

– "Unibox vario (connection for room

temperature control)

0.52 (100) 118 70 77

"Series AV 6", "Series RFV 6" and "Series E" Also for "Hycocon ETZ".

0.65 (100) 118 70 57# #These valve inserts are suitable for all valve

bodies with connection thread M 30 x 1.5 of all

sizes of the "Series A, AV 6, ADV 6, AZ, E, F,

RF and RFV 6".

 Valve insert RTLH (100) 102 69 70 Special valve insert for reversed supply and

return pipe for "Unibox RTL".

Extensions

L = 20 mm

for thermostatic valves (10) 102 26 98 For "Unibox T" and "Unibox plus".

for RTLH valves (10) 102 26 99 For "Unibox RTL" and "Unibox vario".

Gland nut

Set = 5 pieces (10) 102 69 86

Duo connection piece

For the connection of two heating circuits.1 x G ¾ collar nut 2 x G ¾ male thread 102 26 55

 

 Article

kv

at 2K

P-dev.

Packing

unit Article-No. Hint

“Unibox” Room temperature control

Page 75: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 75/108

Page 76: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 76/10876

"Cofloor" Base mat system NP-R

Pre-punched base mat without

thermal insulation with foil overlap on both sides,

for fixing 12 mm pipes

offering the possibility of 45° diagonal laying

without auxiliary material,

laying distances 5, 10, 15 cm

The perforation of the base mats allows a

simple application and a safe bonding of the

levelling compound and the existing ground.

Tested minimum construction heights:

-Knauf levelling compound Alphadur 430

  min. 17 mm

-PCI periplan min. 18 mm

-Weber-Maxit weber.floor min. 18 mm

-Knauf levelling screed min. 21 mm

Further products on request!

The laying advice must be observed.

Base mat NP-R

1.0 x 1.0 m = 1.0 m²

without thermal insulation

made of moulded polystyrene foil,with adhesive layer on reverse

Only sold in units of 10 base mats per box.

(10) 140 20 10

Edge isolating strip

with adhesive edge

and integrated fleece back

height: 50 mm, thickness: 5 mm

Only sold in units of 12 rolls per bag.

length per roll 25 m (12) 140 19 90

PE-RT "Copert" Plastic pipe

with oxygen barrier

in rolls

Dimension 12 x 2.0 mm

 Application:

Surface heating and cooling.

Pipes according toDIN 16833 / DIN 16834 / DIN 4721.

Oxygen tight according to DIN 4726.

Max. operating pressure ps: 6 bar at 70 °C

length per roll 200 m (200) 140 19 52

Duo connection piece

For the connection of two heating circuits.1 x G ¾ collar nut 2 x G ¾ male thread 102 26 55

"Ofix K" compression fittings

“Ofix K” for plastic pipes according to DIN 4726, PE-X according to

DIN 16892/16893, PB according to DIN 16968, PP according to DIN

8078 A1, collar nut unplated, metal to metal sealing plus O-ring

12 x 2 mm (10) 102 77 72

 

 ArticlePacking

unit Article-No. Hint

“Cofloor” Systems“Copex”, “Copipe” and “Copert” pipes and accessories

Page 77: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 77/108

Page 78: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 78/10878

Tape gun

for tapes

For bonding the linings of the base mat roll

breadths or insulation boards.

with a width of 50 mm 140 25 98

 Adhesive tape For bonding the linings of the base mat roll

breadths or insulation boards to prevent

penetration of screed water.50 mm x 66 m (36) 140 25 99

"Cofloor" Clamping rail system

Self-adhesive clamping rail made of polypropylene,

clamping distance 5 cm, length 1 m

For fixing the heating pipes onto the insulation.

for 14 mm pipe (100) 140 25 80

for 16 mm pipe (100) 140 25 81

 

 ArticlePacking

unit Article-No. Hint

“Cofloor” Systems“Copex”, “Copipe” and “Copert” pipes and accessories

Page 79: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 79/10879

"Cofloor" Dry-build system

for fixing 14 mm pipes,

laying distances 12,5 cm, 25 cm

For laying of surface heating systems on solid

or timber beam floors as a dry-build system

(reduced overall thickness, for instance

renovation of existing buildings) or with heating

screed according to DIN 18560 on a

membrane made of polystyrene.

Taking certain installation conditions into

consideration, the dry-build system is also

suitable for wall heating and cooling systems.

Dry-build element

1000 x 500 x 25 mm

made of expanded polystyrene according to DIN EN 13163,

thermal conductivity group 035,

building material class B1 according to DIN 4102

Element for serpentine or spiral laying of the

heat conducting strips and elbows. For

"Copipe HSC" composition pipe 14 x 2 mm.

Only sold in units of 10 boards wrapped up in a

plastic foil.

Thermal resistivity: R = 0.5 (m²K)/W.Max. load: 60 kN/m² (10) 140 28 00

Heat conducting strip

998 x 22 x 0.4 mm

made of galvanised sheet steel

For laying "Copipe HSC" composition pipe 14

x 2 mm and for improvement of the heat

transmission by a largesurface covering of the

dry-build elements.

Only sold in units of 48 strips per box.

with pre-punched break points

in the grooves

(48) 140 28 50

Heat conducting elbow

110 x 245 x 0.5 mm

For serpentine laying of the "Copipe HSC"

composition pipe 14 x 2 mm in the edge areas.

Only sold in units of 25 elbows per box.made of galvanised sheet steel (25) 140 28 55

Infill panel

1000 x 500 x 25 mm

made of expanded polystyrene according to DIN EN 13163,

thermal conductivity group 035, max. load 60 kN/m²,

building material class B1 according to DIN 4102

Only sold in units of 19 panels wrapped up in a

plastic foil.

(19) 140 28 57

Membrane

made of polyethylene 0.2 mm

 As separation layer between dry-build system

and concrete or liquid screed.

Dimensions of roll 25 m x 4 m 140 28 95

Manual tool for cutting individual pipe ductsinto the infill panel.Hot cutting machine 140 28 91

 

 ArticlePacking

unit Article-No. Hint

“Cofloor” Systems“Copex”, “Copipe” and “Copert” pipes and accessories

Page 80: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 80/10880

 Accessories

Edge isolating strip

with bonded foil and perforation,

height: 150 mm, thickness: 10 mm,

made of polyethylene foam

Suitable for concrete and liquid screed

complying with DIN EN 1264-4/ DIN 18560 T2.

Only sold in units of 8 rolls per bag.

length per roll 25 m (8) 140 20 90

Edge isolating strip

with adhesive strip, bonded foil

and perforation,

height: 120 mm, thickness: 10 mm

made of polyethylene foam

length per roll 50 m (10) 140 21 90

Expansion stripwith adhesive edge,

height: 120 mm, thickness: 10 mm,

made of polyethylene foam

To provide screed joints according to DIN EN1264-4 / DIN 18560 T2.

length: 1.20 m (20) 140 20 91

Protection pipe

made of LDPE

For protecting the pipe

- at junction points of screed joints

  according to DIN EN 1264-4 / 

  DIN 18560 T 2

- at the entry points when set in concrete

- at the exit points when set in concrete

Only sold in units of 20 protection pipes

per bag.

Length: 300 mm, slit, (20) 150 11 84

for 14, 16 and 17 mm pipes

Round profile

made of polystyrene foam Ø 20 mm

Only sold in units = 1 dispenser.

Dispenser of 150 m 140 20 92

Pipe guiding elbow

plastic

for 14, 16 and 17 mm pipes

For the inversion and fixing of the PE-X pipes

in case of 90 ° bends, for instance in front of

the distributor/collector and in screed

passages.Set = 10 pieces 140 90 85

Marker point for measuring screed humidity

plastic

To mark the points of measurement of humidity

of the screed.

Set = 5 pieces 140 90 90

Calculation software

for the design of surface heating systems 140 99 99

Screed additive

 Additional component

to produce concrete screed

for heated underfloor constructions

For homogenization and improvement of the

workability as well as for increase of the

concrete screed density.

Content of canister 10 l 140 90 95

 

 ArticlePacking

unit Article-No. Hint

“Cofloor” Systems“Copex”, “Copipe” and “Copert” pipes and accessories

Page 81: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 81/108

Page 82: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 82/10882

“Cofloor” Systems“Copex”, “Copipe” and “Copert” pipes and accessories

Page 83: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 83/10883

"Ofix K" Compression fittings

for G ¾

For the connection of the "Copex" PE-X pipes

and the "Copert" PE-RT pipes to the

distributor/collector and for couplings.

“Ofix K” for plastic pipes according to DIN 4726, PE-X according to

DIN 16892/16893, PB according to DIN 16968, PP according to DIN

8078 A1, collar nut nickel plated, metal to metal sealing plus O-ring

14 x 2 mm (10) 102 77 55

16 x 2 mm (10) 102 77 57

17 x 2 mm (10) 102 77 59

20 x 2 mm (10) 102 77 63

“Ofix K” for plastic pipes according to DIN 4726, PE-X according to

DIN 16892/16893, PB according to DIN 16968, PP according to DIN

8078 A1, collar nut unplated, metal to metal sealing plus O-ring

14 x 2 mm (10) 102 77 75

16 x 2 mm (10) 102 77 7717 x 2 mm (10) 102 77 79

20 x 2 mm (10) 102 77 83

"Cofit S" Compression fittings

for G ¾ male thread according to DIN V 3838 (cone "Euro"),

for "Copipe HSC" composition pipes and, provided similar

preparation is used, for plastic pipes,

metal to metal sealing plus O-ring,

outlet made of brass resistant to dezincification,

compression ring and collar nut made of brass

For the connection of the pipes to the

distributor/collector and for couplings.

(Interior of plastic pipes must be deburred.)

Collar nut nickel plated

14 x 2.0 mm x G ¾ c/nut (10) 150 79 5416 x 2.0 mm x G ¾ c/nut (10) 150 79 55

17 x 2.0 mm x G ¾ c/nut (10) 150 79 59

Collar nut unplated

14 x 2.0 mm x G ¾ c/nut (10) 150 79 74

16 x 2.0 mm x G ¾ c/nut (10) 150 79 75

 

 ArticlePacking

unit Article-No. Hint

“Cofloor” Systems“Copex”, “Copipe” and “Copert” pipes and accessories

Page 84: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 84/10884

"Cofit S" Compression fittings

for G ¾ male thread according to DIN V 3838 (cone "Euro"),

for "Copipe HSC" composition pipes and, provided similar

preparation is used, for plastic pipes,

2-fold, metal to metal sealing plus O-ring,

outlet made of brass resistant to dezincification,

compression ring and collar nut made of brass,

collar nut nickel plated

14 x 2.0 mm x G ¾ collar nut (10) 150 79 34

16 x 2.0 mm x G ¾ collar nut (10) 150 79 35

17 x 2.0 mm x G ¾ collar nut (10) 150 79 37

18 x 2.0 mm x G ¾ collar nut (10) 150 79 38

20 x 2.0 mm x G ¾ collar nut (10) 150 79 39

20 x 2.5 mm x G ¾ collar nut (10) 150 79 40

Double nipples

Double nipple, brass, nickel plated Port G ¾ with tapered sealing according to DIN

 V 3838.G ¾ male x G ¾ male (10) 102 82 63

Double nipple, bronze, unplated

G ¾ M (25) 150 40 54

"Cofit P" Press couplings

for "Copipe HSC" composition pipes and, provided

similar preparation is used, for plastic pipes,

bronze, size 14 and 17 mm made of brass resistant

to dezincification, casing made of stainless steel

(Interior of plastic pipes must be deburred.)

Press coupling

14 x 14 mm (10) 151 25 42

16 x 16 mm (10) 151 25 43

17 x 17 mm (10) 151 25 44

 

 ArticlePacking

unit Article-No. Hint

“Cofloor” Systems“Copex”, “Copipe” and “Copert” pipes and accessories

Page 85: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 85/10885

“Multidis SF/SFB/SFI” Distributors/collectorsfor surface heating and cooling systems

Page 86: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 86/10886

"Multidis SFI" Brass distributor/collector for industrial surface

heating and cooling systems

flat sealing distributor modules, flow distributor with

ball valves and return collector with regulating valves,

extension to max. 20 circuits by connecting the distributor

modules

 Application:

Central heating systems with circulation pump.

Max. operating pressure ps: 6 bar (PN 6)

Max. operating temperature ts: 90 °C

Description:

Pre-assembled distributor modules, one port

G 2 male thread, one port G 2 collar nut, with

G ½ blind plug.

Flow distributor with ball valves. Return

collector with regulating valves.

Heating circuit connections with G 1 male

thread for Oventrop compression fittings.

for 2 circuits 141 44 52

for 3 circuits 141 44 53

for 4 circuits 141 44 54

for 5 circuits 141 44 55

for 6 circuits 141 44 56

 Accessories

Console Consoles with 2 pipe clamps each including

sound insulation supports and quick acting

lock.

Wall attachment included.

for "Multidis SFI" brass 141 44 90

distributor/collector

2-fold, steel galvanised,

adjustable height and depth

Cap G 2 female thread

for "Multidis SFI" brass distributor/ 

collector, 2-fold, brass

141 44 93 For closing the distributor/collector.

Ball valve

flat sealing

DN 50 G 2 F x G 2 M 140 65 86 For isolation of the flow distributors and return

collectors.

"Optiflex" Ball valve

brass, handle with stop

For filling and venting.

self sealing, with coutnernut,

with hose connection (soft seal)

and cap

DN 15 (50) 103 33 14

"Cofit S" Compression fittings

for "Copex" PE-Xc plastic pipes,

2-fold, metal to metal sealing plus O-ring,

outlet bronze / brass resistant to dezincification,

brass compression ring,

brass collar nut, unplated

For the connection of the "Copex" PE-Xc

plastic pipes to the distributor as well as for

couplings.

20 x 3.0 mm x G 1 collar nut (10) 150 79 69

26 x 3.0 mm x G 1 collar nut (10) 150 79 79

 

 ArticlePacking

unit Article-No. Hint

“Multidis SF/SFB/SFI” Distributors/collectorsfor surface heating and cooling systems

Page 87: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 87/10887

 Valve insert

for stainless steel distributors/ collectors "Multidis SF" (25) 140 40 91

Ball valves

flat sealing

DN 20 G ¾ F x G 1 M (10) 140 63 83

DN 25 G 1 F x G 1 M (10) 140 63 84

flat sealing, with thermometer (0–80°C)

with red T-handle

DN 20 G ¾ F x G 1 M 140 64 83

DN 25 G 1 F x G 1 M 140 64 84

flat sealing, with thermometer (0–80°C)

with blue T-handle

DN 20 G ¾ F x G 1 M 140 65 83

DN 25 G 1 F x G 1 M 140 65 84

flat sealing,

with sensor connection M 10 x 1.0

DN 25 G 1 F x G 1 M (10) 140 67 08

Ball valve

for "Multidis SF/SFB" stainless steel distributor/collector

with cone "Euro" Ball valve for the isolation of the heating

circuits at the distributor/collector. Heating

circuit connection G ¾ male thread for

Oventrop compression fittings. Distributor/ 

collector connection with collar nut G ¾ and

O-ring seal.

G ¾ male x G ¾ collar nut (50) 140 65 04

 

 ArticlePacking

unit Article-No. Hint

“Multidis SF/SFB/SFI” Distributors/collectorsfor surface heating and cooling systems

Page 88: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 88/10888

Cabinets

steel, galvanised, frame and doors white lacquered

removable screen

Depth: 115 – 180 mm

Height: 760 – 885 mm

When using heat meter connection sets, the

sum of the installation length and the length of

the distributor have to be taken into

consideration.

Outlet Length (L) No.°°  Length with No.°°ball valves

140 63 842 190 mm 1 270 mm 13 240 mm 1 320 mm 14 290 mm 1 370 mm 15 340 mm 1 420 mm 16 390 mm 1 470 mm 17 440 mm 1 520 mm 28 490 mm 2 570 mm 29 540 mm 2 620 mm 210 590 mm 2 670 mm 311 640 mm 3 720 mm 312 690 mm 3 770 mm 3

°°No. of cabinets

no. 1: inner width: 560 mm 140 11 51

no. 2: inner width: 700 mm 140 11 52

no. 3: inner width: 900 mm 140 11 53

no. 4: inner width: 1200 mm 140 11 54

Surface-mounted cabinetssteel, galvanised, frame and doors white lacquered

Depth: 160 mmHeight: 760 – 870 mm

When using heat meter connection sets, the

sum of the installation length and the length of

the distributor have to be taken into

consideration.

no. 1: inner width: 600 mm 140 11 71

no. 2: inner width: 750 mm 140 11 72

no. 3: inner width: 1000 mm 140 11 73

no. 4: inner width: 1250 mm 140 11 74

Cylinder lock

with key

for surface-mounted cabinets 140 11 90 Only suitable for surface-mounted cabinets as

from November 2011.(140 11 71 - 74)

for cabinets 140 11 91

(140 11 51 - 54)

 

 Article Article-No. Hint

“Multidis SF/SFB/SFI” Distributors/collectorsfor surface heating and cooling systems

Page 89: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 89/10889

Heat meter connection sets

for "Multidis SF/SFB" stainless steel distributors/collectors for surface

heating and cooling systems as well as for "Multidis SH" stainless steel

distributors/collectors for radiator connection

Heat meter connection sets are suitable for left

and right hand side connection to the

distributor/collector.

Set no. 1 consists of:

Supply

- Ball valve with temperature sensor

connection

Return

– Double regulating and commissioning valve

  "Hycocon VTZ"

– Meter stool piece

– Ball valve with coupling

– Flat seals

Illustr. example:

Set no. 1 angle pattern

Set no. 1

with double regulating and commissioning valve

“Hycocon VTZ”

 Angle pattern:

with ball valves DN 20 140 45 78

with ball valves DN 25 140 45 80

Straight pattern:

with ball valves DN 20 140 45 79

with ball valves DN 25 140 45 81

Illustr. example:

Set no. 2 angle pattern

Set no. 2

with differential pressure regulator “Hycocon DTZ”

 Angle pattern:

Set no. 2 consists of:

Supply

– Ball valve with temperature sensor

  connection

– Measuring adapter

Return

– Differential pressure regulator

  “Hycocon DTZ”

– Capillary

– Meter stool piece

– Ball valve

– Flat seals

with ball valves DN 25 140 46 80

Straight pattern:

with ball valves DN 25 140 46 81

Set no. 3

with pressure independent control valve „Cocon QTZ“

 Angle pattern:

Set no. 3 consists of:

Supply

- Ball valve with temperature sensor

  connection

Return

- Pressure independent control valve

  "Cocon QTZ" (control range 150 - 1050 l/h)

- Meter stool piece

- Ball valve

- Flat seals

with ball valves DN 25 140 48 80

Straight pattern:

with ball valves DN 25 140 48 81

 

 Article Article-No. Hint

“Multidis SF/SFB/SFI” Distributors/collectorsfor surface heating and cooling systems

Page 90: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 90/10890

Differential pressure relief device

for "Multidis SF/SFB" stainless steel distributors/collectors

Differential pressure relief device for the right

hand side connection to the distributor/ 

collector.

To avoid flow noises.

Control range: 50-400 mbar

G ¾ male thread 140 47 90

 Angle pattern connection set  Angle pattern connection set for a bottom

connection to the distributor/collector when

using surface-mounted cabinets.for "Multidis SF/SFB" stainless steel distributors/collectors for surface

heating and cooling systems as well as for "Multidis SH" stainless steel

distributors/collectors for radiator connection

140 47 80

"Hycocon VTZ" Double regulating and commissioning valve

with infinitely adjustable presetting

"eco" measuring technique

both ports with integrated pressure test points and drain valves

"eco" measuring technique:

Information: page 3. 00 .

Operating temperature:

-10 °C up to +120 °C

General information:

Body and bonnet made of brass resistant to

dezincification.

Male thread G 1.

both ports male thread, flat sealing

DN 20 2.70 (10) 106 18 56

"Hycocon DTZ" Differential pressure regulator

nominal value: 50 to 300 mbar, infinitely adjustable

"eco" measuring technique

with integrated pressure test point and drain valve

"eco" measuring technique:

Information: page 3. 00 .

Operating temperature:

-10 °C up to +120 °C

General information:

Body and bonnet made of brass resistant to

dezincification.Male thread G 1.

both ports male thread without collar nut

DN 20 2.70 106 21 56

 

 Article kvsPacking

unit Article-No. Hint

“Multidis SF/SFB/SFI” Distributors/collectorsfor surface heating and cooling systems

Page 91: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 91/10891

"Regufloor H"

"Control unit DN 25 Heating

for connection to the stainless steel distributor/collector

 Application ("Regufloor H and HW"):

Fixed value control unit for connection to

the stainless steel distributor/collector for

surface heating systems.Connection of 2 - 12 heating circuits.

Length: 315 mm

Depth: 145 mm

Pump length: 130 mm

Max. operating pressure: 6 bar

Max. differential pressure: 0,75 bar

Max. flow temperature:

Primary side: 90 °C

Secondary side: 50 °C

Control range:

("Regufloor H" only): 20–50 °C

Electric sensor attached to pipe

Temperature range: 20–90 °C

Description ("Regufloor H"):

Pre-assembled and tested fixed value control

unit with electronic pump, three-way diverting

valve, check valve, temperature controller with

contact sensor. Electric pipe contact safety

switch for max. limitation of the flow

temperature.

Description ("Regufloor HW"):

 As "Regufloor H" but three-way diverting valve

with electromotive actuator (three point),

heating circuit controller with outdoor sensor

and flow temperature sensor.

with high-efficiency pump 115 13 00

Wilo Yonos Para

(Energy Efficiency Index EEI ≤ 0.23

according to EC Regulation 641/2009)

with Wilo pump E15/ 1-5 115 10 00

(export model, only for sales outside

the European Union)

"Regufloor HW"

Control unit DN 25 Heating

as above, but with

weather guided control for connection

to the stainless steel distributor/collector

with high-efficiency pump 115 18 00*Wilo Yonos Para and

heating circuit controller "Regtronic RH-B"

(Energy Efficiency Index EEI ≤ 0.23

according to EC Regulation 641/2009)

with Wilo pump E15/1-5 and 115 15 00

heating circuit controller "Regtronic EH"

(export model, only for sales outisde

the European Union) 

System components For the isolation of the supply and return,

use Oventrop ball valves

item no. 140 63 83 DN 20 and

item no. 140 63 84 DN 25.

T-connection piece 115 10 80 With check valve and sensor point.

Three-way diverting valve

with S-connection fitting 115 10 81

Temperature controller Control range 20–50 °C.

Only supplied as replacement.with contact sensor 115 10 82

Pump without pump cable.

Only supplied as replacement.WILO E15/1-5 115 10 86

(export model, only for sales

outside the Europan Union)

 

 Article Article-No. Hint

 

“Regufloor” Control units

Page 92: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 92/10892

Pump without pump cable. Only supplied as

replacement.High-efficiency pump 115 10 88*Wilo Yonos Para

(Energy Efficiency Index EEI ≤ 0.23according to EC Regulation 641/2009)

Including cabling for Wilo pump E15/1-5.Electric pipe contact safety switch 115 10 87

Bracket

T-connection piece 115 10 85

 

 Article Article-No. Hint

 

"Regtronic EH" Heating circuit controller Weather-guided control of the flow

temperature of the heating system by

activation of a heat generator and/or a mixing

valve.with 1 outdoor sensor and 3 further sensors (NTC 5000)

230 V 115 20 92°

 

“Regufloor” Control units

 

"Regtronic RH-B" Heating circuit controller Weather guided flow temperature control of the

heating system via the demand of a heat

generator and/or a mixing valve (e.g. "Regumat

M3" or "Regufloor HW" with three-way mixing

valve). Controller for wall attachment with data

bus (S-bus).

Basic functions: 1 variable and 1 constant

temperature circuit with heat demand.Extendable by "Regtronic EM-B". The status

can be viewed via a full graphic display.

Interfaces: S-bus, SD-card slot for data

recording

Inputs: 8 sensor inputs (PT 1000, KTY, switch

or remote control), inputs for electronic volume

flow sensor/pressure sensor and irradation

sensor

Outputs: 4 solid-state relays (speed controlled),

1 standard relay (volt free), 2 PWM outputs for

the speed controlled activation of high-

efficiency pumps. Both PWM outputs can be

switched to 0-10 V.

with 1 outdoor sensor 115 20 93

and 3 further sensor (PT 1000)

 

 Accessories

Room temperature sensor 115 20 95 Room temperature sensor for fixing on level

surfaces (surface mounting).PT 1000

Remote control with room temperature sensor

PT 1000 for the connection to the heating

circuit controller "Regtronic RH-B" for acomfortable control of the heating curve of the

controller from the living area. When increasing

the heating curve, the flow temperature is

increased and vice versa. The remote control

also features the functions "heating circuit off"

and "party position".

Remote control with

room temperature sensor

115 20 96

PT 1000

 

"Regtronic EM-B" Extension module "Regtronic EM-B" for the extension of the

heating circuit controller "Regtronic RH-B" by 6sensor inputs and 5 relay outputs.

This allows the activation of further variable

and constant temperature circuits.

Up to five extension modules can be

connected to the heating circuit controller

"Regtronic RH-B".

1 sensor attached to pipe PT 1000 is included.

for the connection to the heating circuit 115 20 98

controller "Regtronic RH-B"

 

Page 93: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 93/10893

"Regufloor HC"

Control unit DN 25 Heating/Cooling

for connection to the stainless steel distributor/collector

 Application:

Control unit for flow temperature control of

surface heating systems or alternatively of

surface cooling systems in conjunction with the

Oventrop stainless steel distributors/collectors.

Pre-assembled and tested control unit with

electronic pump and three-way diverting valve.

Suitable for the connection of 2 - 12 heating

circuits to two, three and four pipe systems

Heating and Cooling.

Length: 315 mm

Max. operating pressure: 6 bar

Max. differential pressure: 0.75 bar

Max. flow temperature:

Primary side: 90 °C

Secondary side: 50 °C

with high-efficiency pump 115 21 00*Wilo Yonos Para

(Energy Efficiency Index EEI ≤ 0.23

according to EC Regulation 641/2009)

with Wilo pump E15/1-5 115 20 00

(export model only for sales outside

the European Union)

System components for "Regufloor HC"

Flow temperature control set:

Climate controller heating/cooling

Memory stick

Electrothermal actuator

Outdoor sensor

Flow temperature sensor

Room humidity measuring transducer

Electric sensor attached to pipe

Electromotive actuatorMains adaptor

The flow temperature control set for outside

temperature guided surface heating and

cooling systems enables an automatic

changeover from heating to cooling. By

calculating the dew point, condensation is

prevented by an automatic adjustment of the

flow temtemperature. The control includes

heating and cooling curve, changeover for the

individual room temperature controls as well astimed programmes.

115 20 20

Optional accessory for the remote control of

the climate controller heating/cooling.Remote control for the climate 115 20 25

controller heating/cooling

Connection system for

room thermostats and actuators

Connection system for installation into the

distributor/collector cabinet with 6 channels for

the connection of the room thermostats and

actuators. Several connection systems can be

installed in parallel. The connection system andthe flow temperature concontrol set are co-

ordinated.

230 V 115 20 45

Room thermostat for individual room

temperature control. Adjustment of the nominal

temperature value, absence or presence. Entry

for operating mode changeover from heating or

cooling.

Room thermostat 115 20 63

heating/cooling 230 V

 

 Article Article-No. Hint

 

“Regufloor” Control units

Page 94: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 94/10894

"Aktor T 2P" Electrothermal actuators (two point)

connection thread M 30 x 1.5

Oventrop electrothermal actuators are used for

heating, ventilation and air-conditioning. The

actuators serve to control the room

temperature and can be used e. g. with

conventional radiators, radiators with

integrated distributor, distributors for surface

heating, radiant ceiling panels, chilled ceiling

systems and induction air systems in

combination with two point room thermostats.

Further applications in bivalent heating

installations.

For zone and room temperature control.

Connecting cable 1 m.

With First-Open function (except for actuators

"opened with current off") and stroke index.

Simple plug-in connection with valve adapter.

 Actuators can be installed in any position.

 As for the model with auxiliary switch, a pump

can e. g. be switched via the integrated volt

free contact. Due to their construction, the

electrothermal actuators are secured against

overvoltage which could occur when switching

on neon tubes. A varistor is thus not necessary.

"H NC", closed with current "off", 230 V 101 28 15"L NC, closed with current "off", 24 V 101 28 16

Dew point control 24 V "Sensos GA FD" Is required in combination with room

thermostats to protect chilled ceilings against

condensation.

 An actuator interrupting the cooling water flow

is for instance activated in conjunction with the

"Regufloor HC".

Connection to the cooling water supply.

Connecting cable 1 m.

with alternating contact 114 19 51

System components

Controller for universal application in air

conditioning and heating systems, for instance

for flow temperature control in surface heating

and cooling systems. With integrated

measuring, control and timed function via two

PI controllers and preset parameters for an

easy initial operation.

Controller heating/cooling 115 30 41

Including cabling for Wilo pump E15/1-5.Electric pipe contact safety switch 115 10 87

Optional plug-in memory for controller heating/ 

cooling for documentation and copying of

parameter settings.

Memory for controller heating/cooling 115 30 42

 

 Article Article-No. Hint

“Regufloor” Control units

Page 95: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 95/108

Page 96: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 96/10896

"Regufloor HX"

Control unit DN 25 Heating

for connection to the stainless steel distributor/collector.

For flow temperature control of

surface heating systems, with heat exchanger.

 Application:

Fixed value control unit for the operation

of open vented surface heating systems in

heating systems (separate circuits).

Installation on the left hand side of the

distributor/collector.

Connection of 2-12 heating circuits.

Max. operating pressure:

Primary side: 6 bar

Secondary side: 3 bar

Max. flow temperature:

Primary side: 90 °C

Secondary side: 50 °C

Control range: 20–50 °C

Description:

Pre-assembled and tested fixed value control

unit with electronic pump (plastic body).

Heat exchanger, diaphragm expansion tank

(3 l), pressure gauge, safety valve.

with high-efficiency pump 115 10 65*Wilo Yonos Para

(Energy Efficiency Index EEI ≤ 0.23

according to EC Regulation 641/2009)

with Wilo pump E15/1-5 115 10 60

(export model, only for salesoutside the European Union)

 

"Tri-D TR" Three-way diverting valves PN 16

bronze

connection thread M 30 x 1,5

with collar nuts, flat sealing

 Application:

Max. operating pressure ps: 16 bar (PN 16)Operating temperature ts: 0 °C up to 120 °C

Diverting, mixing or changing-over of flow

volumes in heating and cooling systems in

combination with thermostatic or electric

actuators.OV

I   II

III

DN 20 4.50 113 02 06

DN 25 6.50 113 02 08

DN 40 9.50 113 02 12

"Tri-M TR" Three-way mixing valves PN 16

bronze

connection thread M 30 x 1,5with collar nuts, flat sealing

Male thread:

G 1

G 1 ¼

G 2

B

AAB

OV

DN 20 4.50 113 17 06

DN 25 6.50 113 17 08

DN 40 9.50 113 17 12

 

“Regufloor” Control units

 

 Article kvs Article-No. Hint

 

Page 97: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 97/10897

Room thermostats, clocks

Electronic room thermostat-surface mountingfor steady control (0 - 10 V) The electronic room thermostat is required forindividual room temperature control in

conjunction with the electrothermal actuator

(0- 10 V), item no. 101 29 52, page 1. 00 ,

or the electromotive actuator, item no.

101 27 05/06, page 1. 00 (may also be used

in three or four pipe systems).

With one analogue output 0–10 V each for

heating and cooling as well as adjustable

neutral zone (0.5–7.5 K).

Temperature range: 5 °C up to 30 °C

24 V 115 21 51

Room thermostat-clock - surface mounting

with daily setting

The electric room thermostat-clock is required

for individual room temperature control ofheating systems in conjunction with the

electrothermal actuators (two point). Output

signal pulse-width modulation.

Temperature range: 5 °C up to 30 °C

Heating:

Use electrothermal actuators (two point)

“closed with current off”.

Central temperature setback is carried out

according to a timed programme.

Limitation of the control range by using the

hidden limiting elements.

230 V 115 25 51

with weekly setting

230 V 115 25 52

24 V 115 25 54

Protection cover

for room thermostat-clock 230 V 115 25 91

Room thermostat - surface mounting The surface- or flush-mounted model of the

electric thermostat is required for individual

room temperature control in conjunction with

the electrothermal actuators (two point).

Temperature range: 5 °C up to 30 °C

Heating: Use electrothermal actuators (two

point) “closed with current off”. As for item no.

115 20 51/52/71/72, temperature may be set

back by use of an external time switch (item

no. 115 25 51/52 for 230 V, item no. 115 25 54

for 24 V).

Cooling: Use electrothermal actuators (two

point) “opened with current off”.

Limitation of the control range of item no.

115 20 51/52/ 71/72 by using the hidden

limiting elements.

230 V 115 20 51

24 V 115 20 52

 

 Article Article-No. Hint

Room thermostats, actuators, wireless controls

Page 98: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 98/10898

 

 Article Article-No. Hint

Room thermostats, actuators, wireless controls

"Aktor T" Electrothermal actuators

"Aktor T 2P" Electrothermal actuators (two point)connection thread M 30 x 1.5

Oventrop electrothermal actuators are used forheating, ventilation and air-conditioning. The

actuators serve to control the room

temperature and can be used e. g. with

conventional radiators, radiators with

integrated distributor, distributors for surface

heating, radiant ceiling panels, chilled ceiling

systems and induction air systems in

combination with two point room thermostats.

Further applications in bivalent heating

installations.

For zone and room temperature control.

Connecting cable 1 m.

With First-Open function (except for actuators

"opened with current off") and stroke index.

Simple plug-in connection with valve adapter.

 Actuators can be installed in any position. As for the model with auxiliary switch, a pump

can e. g. be switched via the integrated volt

free contact. Due to their construction, the

electrothermal actuators are secured against

overvoltage which could occur when switching

on neon tubes. A varistor is thus not necessary.

"H NC", closed with current "off", 230 V 101 28 15

"L NC, closed with current "off", 24 V 101 28 16

 Accessories

Connecting block (6 control zones)

for room thermostats and and actuators 140 10 80

Connecting block (8 control zones)

for room thermostats and actuators 140 10 81

Suitable for connecting blocks 140 10 80 and

140 10 81 to switch off the pump when all

valves are closed.

Pump logic 24 V 140 10 85

Pump logic 230 V 140 10 86

 

Room thermostat - flush mounting

230 V 115 20 71

24 V 115 20 72

Room thermostat - flush mounting

digital

With LCD display and adjustable timed

programme.

Temperature range: 5 °C up to 35 °C230 V 115 25 61

24 V 115 25 62

Page 99: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 99/10899

Room thermostats with wireless transmitter, wireless receiver The room thermostat with wireless transmitter

is used for individual room temperature control

in conjunction with the wireless receiver and

electrothermal actuators (two point). With

switch for the functions heating and cooling.

With switch for the operating modes automatic

operation (in combination with room

thermostat-clock with wireless transmitter),

daytime operation, night setback (choice of 2K

or 4K), off.

With valve protection function.

Temperature range: 5 - 30 °C

The temperature range may be limited by using

the hidden limiting elements.

oventrop

°C

1  5   

1    0     

 5   

  2  5

    3    0

Room thermostat with wireless transmitter

3 V, including 2 batteries, 1.5 V each

(round cells, alkaline, type LR 03 or AAA,

service life approx. 3 years)

115 05 51

Room thermostat-clock with wireless transmitter

3 V, including 2 batteries, 1.5 V each

(round cells, alkaline, type LR 6 or AA service life approx. 2 years)

The room thermostat-clock with wireless

transmitter is used for individual room

temperature control in conjunction with thewireless receiver and electrothermal actuators

(two point).

Functions: heating and cooling.

Timed temperature control. The switching

times and nominal temperatures can be

easily adapted individually. The room

thermostat-clock can be used as master for

further room thermostats.

With valve protection function.

Temperature range: 5–32 °C

115 05 53

Wireless receiver, 1 channel Receiver for 1 room thermostat with wireless

transmitter, item no. 115 05 51/53.

 Voltage free switching operation (relay version)

of electrothermal actuators (two point) 24 Vand 230 V.

Functions: heating and cooling.

230 V 115 05 60

Wireless receiver, 4 channels Receiver for 4 or 6 room thermostats with

wireless transmitter, item no. 115 05 51/53.

Electrothermal actuators (two point) 230 V can

be clipped on directly.

Electrothermal actuators (two point) 24 V can

be operated via voltage free contacts, a

separate transformer is required.

Channel 4 or 6 can be used for the activation

of a pump.

Functions: Heating and cooling

230 V, with plug 115 05 61

Wireless receiver, 6 channels

230 V, with plug 115 05 62

 

 Article Article-No. Hint

Room thermostats, actuators, wireless controls

Page 100: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 100/108100

Wireless receiver with time switch

8 channels

230 V, with plug,

cover with operating device removable

8 channel time switch for a timed

control of up to 8 independent zones

(with room thermostat with wireless

transmitter, item no. 115 05 51/52).

Programming of the time switch

and adaptation of the transmitter

only possible after having removed

the cover (device must be disconnected

from the power supply).

Electrothermal actuators (2 point)

230 V can be connected directly.

Functions:

– Pump logic

– Valve protection function

– Changeover from heating to cooling

  via external signal

(incl. battery) 115 05 63

Wireless repeater 115 05 67 The wireless transmitter automatically amplifies

the radio signals received from the room

thermostats with wireless transmitter.

It increases the radio range between the

wireless room thermostats and the wireless

receivers and improves the transmission safety

under difficult conditions.

The radio repeater can be directly plugged into

an earthed plug, the socket can still be used.

230 V

 

 Article Article-No. Hint

Regulating sets for surface heating systems

with bypass valve

 Application:

The regulating set with bypass valve is required

for the control of the flow temperature of a

surface heating system, for instance in

combined radiator/surface heating systems.

The required flow temperature is set at the

temperature controller. The electric pipe

contact safety switch switches the circulation

pump off as soon as the set flow temperature

is exceeded. The bypass valve serves to

regulate the flow rate of the surface heating

circuit.

Bypassventil

 Vorlaufventil

ElektrischerRohranlegeregler

Temperaturreglermit Anlegefühler

Vorlauftemperaturbegrenzung

Temperature controller withcontact sensor

Supplyvalve

Electric sensorattached to pipe

Bypassvalve

Flow temperature limiting

Example:

For further information see "Technicalinformation".

  3  5 4

   o  v  e   n  t  r   o   p

Set no. 1

for surfaces up to 85 m² 114 42 51

consisting of:

 

 Valve DN 15, brass, nickel plated

straight pattern

item no. 118 01 04 (M 30 x 1.5)

Bypass valve DN 20, brass, nickel plated

straight pattern

item no. 102 76 66

Temperature controller

with contact sensor

and heat transfer unit

capillary 2 m long

control range 20–50 °C

item no. 114 28 61 (M 30 x 1.5)

Electric pipe contact safety switch

with hidden temperature setting

control range 20–90 °C

item no. 114 30 00

 

Room thermostats, actuators, wireless controls

Regulating sets for surface heating systems

Page 101: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 101/108101

 

  3  5 4

   o  v  e   n  t  r   o   p

Set no. 2

for surfaces up to 120 m² 114 42 52

consisting of:

 

 Valve DN 20, brass, nickel plated

straight pattern

item no. 118 71 06 (M 30 x 1,5)

Bypass valve DN 25, brass, nickel plated

straight pattern

item no. 102 76 68

Temperature controller

with contact sensor

and heat transfer unit

capillary 2 m long

control range 20–50 °C

item no. 114 28 61 (M 30 x 1.5)

Electric pipe contact safety switch

with hidden temperature setting

control range 20–90 °C

item no. 114 30 00

Regulating set for surface heating systems

with "Tri D TR" three-way diverting valve

 Application:

The regulating set with "Tri-D TR" three-way

diverting valve is required for the control of theflow temperature of a surface heating system,

for instance in combined radiator/surface

heating systems. The required flow rate is set

at the temperature controller. The electric pipe

contact safety switch switches the pump off as

soon as the set flow temperature is exceeded.

Depending on the setting of the temperature

controller, the three-way diverting valve divides

the flow volume into a return flow and a bypass

flow. The check valve installed in the bypass

prevents a wrong flow against the three-way

diverting valve.

Electric sensorattached to pipe

Non-return check valveitem no. 107 20 06

Temperaturecontrolleritem no. 114 28 61

“Tri-D TR” Three-way diverting valve

Example:

  3  5 4

   o  v  e   n  t  r   o   p

OV

I   II

III

Set no. 3

for surfaces up to 200 m² 114 42 53

consisting of:

 

Three-way diverting valve „Tri-D TR“

DN 20 bronze

item no. 113 02 06 (M 30 x 1.5)

Temperature controller

with contact sensor

and heat transfer unit

capillary 2 m long

control range 20–50 °Citem no. 114 28 61 (M 30 x 1,5)

Electric pipe contact safety switch

with hidden temperature setting

control range 20–90 °C

item no. 114 30 00

Piston type spring assisted check valve DN 20

bronze/brass

item no. 107 20 06

 

Regulating sets for surface heating systems

 

 Article Article-No. Hint

Page 102: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 102/108102

Return temperature limiter set Packed as a set.

 Valve and thermostat "Uni RTLH".

Thermostat "Uni RTLH" limited at works

to 40 °C.Reversed angle connectionconsisting of:

Reversed angle pattern valve for the return pipe and

thermostat “Uni RTLH”

DN 15 0.30 102 83 64

Straight pattern connection

consisting of:

Straight pattern valve for the return pipe and

thermostat “Uni RTLH”

DN 15 0.30 102 84 64

Return temperature limiters

 Valves for thermostats "Uni RTLH"

connection thread M 30 x 1.5

brass, nickel plated

 Application:

Central heating systems PN 10,

combined radiator/surface heating systems.

 Valve insert with double disc prevents

inadvertent overheating, with frost protection.Reversed angle pattern valve for the return pipe

DN 10 0.30 (25) 102 43 63

DN 15 0.30 (25) 102 43 64

Straight pattern valve for the return pipe

DN 10 0.30 (25) 102 44 63

DN 15 0.30 (25) 102 44 64

 

 Article kvsPacking

unit Article-No. Hint

Thermostat "Uni RTLH"

connection thread M 30 x 1.5

With '0' setting,

may be limited or locked.

10-40 °C factory setting

(return temperature) may be increased

to 50 °C by cancelling the limitation (40 °C).white model (25) 102 71 65

chrome plated model (25) 102 71 72

Thermostat "Uni RTL"

connection thread M 30 x 1.5

With '0' setting,

may be limited or locked.

RTL valves with connection thread M 30 x 1.0

are no longer produced.white model (25) 102 71 00

 Valve insert

for return flow valves (100) 102 69 81  Valve insert with double disc.

Prevents inadvertent overheating,

with frost protection.

Gland nut

for all RTLH valves

Set = 5 pieces (10) 102 69 86

 

Return temperature limiter sets

Page 103: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 103/108103

Individual components for distributor systems Distributor systems for central heating

systems.

If not stated otherwise, all products are madeof brass.

Brass automatic airvent

with automatic shut off

G ⅜ (10) 108 83 03

 Vent plug G ⅜

self sealing, set = 10 pieces 140 03 92

self sealing, with coutnernut,

with hose connection (soft seal)

and cap

DN 10 (50) 103 33 13

Flow valve “Series AZ”

for thermostatic control

(to be discontinued)

 Valve for the flow distributor of

surface heating systems.

DN 15 G ¾ M x G ¾ F (25) 140 01 64

Return flow lockshield valve “Combi 2”

with presetting and isolating facility

(to be discontinued)

Lockshield valve for the return collector

of underfloor heating systems.

DN 15 G ¾ M x G ¾ F (25) 140 11 94

OV

Brass terminal distributor/collector G 1 female thread

G ¾ male thread for circuit connection

G ⅜ female thread for airvent connection

4 outlets (2) 140 05 54

OV

Brass distributor/collector G 1 female thread x G 1 male thread

G ¾ male thread for circuit connection

2 outlets (2) 140 06 52

OV

3 outlets (2) 140 06 53

OV

4 outlets (2) 140 06 54

OV

Terminal cap G 1 female thread (10) 140 06 91

G ⅜ female thread for airvent connection

G ½ female thread for fill and drain ball valve connection

Ball valve DN 25 (10) 140 63 94

with coupling

flat sealing

Bracket Bracket with mounting clip.

For the installation of the distributor/collector

into the cabinet or onto the wall.

Sound absorbing as per DIN 4109.

steel, galvanised 140 10 61

 

 ArticlePacking

unit Article-No. Hint

Single components for distributors/collectors

Page 104: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 104/108104

 Accessories

  0

                  1

   2

34    

5          

Thermostat with remote control "Uni FH"

white model

capillary 2 m long (40) 101 22 95 with '0' setting

capillary 5 m long (40) 101 22 96

capillary 10 m long (40) 101 22 97

5          

4    3

   2

                  1

  0

white model,

with additional remote sensor

capillary 2 m long 101 23 95 with '0' setting

capillary 5 m long 101 23 96

Manual heads

white model

The manual head allows the subsequent

conversion to actuators or thermostats without

the necessity to drain the system.connection thread (10) 101 25 65

M 30 x 1.5

0 120

6080

°C

100

40

20

oventrop

Contact thermometer

for distributors/collectors (50) 140 40 95

Coupling

DN 15 (G ¾ c/nut x R ½ M) (50) 101 93 04

Blind plug G ½

self sealing 140 17 04

To close outlets not in use.Cap G ¾ female thread 140 06 92

(not illustr.)

Can be used instead of a cap, but does not

allow the connection of an airvent or a filland drain ball valve.

Cap G 1 female thread 140 06 93(not illustr.)

Ring spanner For the installation of the compression fittings.

Spanner size 30/32 140 10 91

 

 ArticlePacking

unit Article-No. Hint

Single components for distributors/collectors

Page 105: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 105/108105

"Multidis SF" Stainless steel distributor/collector 1"

for surface heating systems/concrete core activation

with integrated regulating inserts (flow distributor) 

flat sealing, with valve inserts M 30 x 1.5

for thermostatic and electronic control

 Application:

Stainless steel distributor/collector for central

heating systems with circulation pump.

Max. operating pressure ps: 6 bar (PN 6)

Max. operating temperature ts: 80 °C

Description:

Distributor/collector pre-assembled. With fill

and drain valves, vent plugs and terminal

caps. Heating circuit connections G ¾ male

thread for Oventrop compression fittings.

Flow distributor with integrated regulating

inserts.

Return collector with integrated valve inserts.

Bracket (loosely added) sound-absorbing

according to DIN 4109.

for 2 circuits 140 45 52

for 3 circuits 140 45 53

for 4 circuits 140 45 54

for 5 circuits 140 45 55

for 6 circuits 140 45 56

for 7 circuits 140 45 57

for 8 circuits 140 45 58

for 9 circuits 140 45 59

for 10 circuits 140 45 60

for 11 circuits 140 45 61

for 12 circuits 140 45 62

Further distributors for surface heating: page 2.40

PE-Xc "Copex" Plastic pipes

with oxygen barrier

rolls

 Application:

Surface heating and cooling.

Pipes according to DIN 16892/DIN 16893/DIN

EN ISO 15 75/EN 1265-4.

Oxygen tight according to DIN 4726 (all

dimensions).

Further dimensions: page 2.34

Dimension 17 x 2 mm Max. operating pressure ps:

6 bar at 90 °C

10 bar at 60 °Clength per roll 120 m (120) 140 02 51

length per roll 240 m (240) 140 02 52

length per roll 600 m (600) 140 02 54

"Cofit S" Compression fittings

for "Copex" Pe-Xc plastic pipes,

2-fold, metal to metal sealing plus O-ring,

outlet made of bronze,

brass compression ring and collar nut,

collar nut nickel plated

For the connection of the "Copex" PE-Xc

plastic pipes to the distributor/collector and for

couplings.

17 x 2.0 mm x G ¾ collar nut (10) 150 79 37

 

 ArticlePacking

unit Article-No. Hint

Components for concrete core activation

Page 106: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 106/108106

"Multidis SFI" Brass distributor/collector for

industrial surface heating/concrete core activation

Distributor modules flat sealing,

flow distributor with ball valves,

return collector with regulating valves,

extension to max. 20 circuits by connecting the distributor modules

 Application:

Central heating systems with circulation pump.

Max. operating pressure ps: 6 bar (PN 6)

Max. operating temperature ts: 90 °C

Description:

Distributor modules pre-assembled. One port

G 2 male thread, one port G 2 collar nut with G

½ blind plug.

Flow distributor with ball valves.

Return collector with regulating valves.

Heating circuit connections with G 1 male

thread for Oventrop compression fittings.

for 2 circuits 141 44 52

for 3 circuits 141 44 53

for 4 circuits 141 44 54

for 5 circuits 141 44 55

for 6 circuits 141 44 56

PE-Xc "Copex" Plastic pipes

with oxygen barrier

rolls

 Application:

Surface heating and cooling.

Pipes according to DIN 16892/DIN 16893/DIN

EN ISO 15 875/EN 1264-4 (except for

dimension 26).

Oxygen tight according to DIN 4726 (all

dimensions).

Dimension 20 x 2 mm Max. operating pressure ps:

6 bar at 90 °C

8 bar at 70 °Clength per roll 240 m (240) 140 03 52

length per roll 600 m (600) 140 03 54

Dimension 26 x 3 mm Max. operating pressure ps:

6 bar at 90 °C

10 bar at 60 °Clength per roll 50 m (50) 140 05 60length per roll 200 m (200) 140 05 62

length per roll 300 m (300) 140 05 63

Dimension 32 x 3 mm Max. operating pressure ps:

6 bar at 90 °C

8 bar at 60 °C

10 bar at 20 °C

length per roll 50 m (50) 140 06 60

"Cofit S" Compression fittings

for "Copex" PE-XC plastic pipes,

2-fold, metal to metal sealing plus O-ring,

outlet bronze / brass resistant to dezincification,

brass compression ring,

brass collar nut, unplated

For the connection of "Copex" PE-Xc plastic

pipes to the distributor/collector and for

couplings.

20 x 3.0 mm x G 1 collar nut (10) 150 79 69

26 x 3.0 mm x G 1 collar nut (10) 150 79 79

Console Consoles with 2 pipe clamps each including

sound insulation supports and quick acting

lock.

Wall attachment included.

for "Multidis SFI" brass 141 44 90

distributor/collector

2-fold, steel galvanised,

adjustable height and depth

Cap G 2 female thread

for "Multidis SFI" brass distributor/ 

collector, 2-fold, brass

141 44 93 For closing the distributor/collector.

 

 ArticlePacking

unit Article-No. Hint

Components for concrete core activation

Page 107: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 107/108107

Ball valve

flat sealing

DN 50G 2 F x G 2 M

140 65 86 For isolation of the flow distributors and returncollectors.

"Optiflex" Ball valve

brass, handle with stop

For filling and venting.

self sealing, with coutnernut,

with hose connection (soft seal)

and cap

DN 15 (50) 103 33 14

Pressure test plug

150 60 95

150 60 96

Compressed air pipe connection

150 61 95

150 61 96

 

 ArticlePacking

unit Article-No. Hint

Components for concrete core activation

Page 108: Catalog Cofloor

8/10/2019 Catalog Cofloor

http://slidepdf.com/reader/full/catalog-cofloor 108/108

For further information refer to our catalo-gue and technical data sheets as well asour homepage www.oventrop.de, productrange 2.

Detailed installation instructions can foundon the technical data sheets “Cofloor”.

Subject to technical modification without

 Advantages, service

1  The almost ideal “temperature profile”from floor to ceiling.Compared to other heating systems, thesurface heating can be referred to as the

heating system with the ideal temperatureprofile. Depending on its usage, the hotwater surface heating system offers theadvantage that an energy saving of 6 to12% may be achieved due to the lowertemperature of the heating medium and thelower room temperature.

2  As system supplier of the surface heatingand cooling system “Cofloor”, Oventropoffers high quality system solution guaran-teeing maximum benefit for the installationand the later comfort. This does, at thesame time, mean an obligation to observe amultitude of rules and standards.

3, 4  Working supportsOventrop supports its partners regardingplanning, calculation, completion andregulation. Current information materiallike catalogues, technical data sheets andcolour leaflets as well as CDs and softwareare available.

DW8501AT2407

16° 20° 24°

Idealheizung

16° 20° 24°

Fußbodenheizung

16° 20° 24°

Heizkörper Außenwand

2,70 m

1,80 m

0,10 m

Heizkörper Innenwand

16° 20° 24°

1

2 3

o  m 

Ideal heating Surface heating Radiator outer wallRadiator outer wall Radiator inner wall