catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

130
GEA Tuchenhagen Hygienic Centrifugal Pumps Business Line Hygienic Pump Technology Catalog 2014 engineering for a better world GEA Mechanical Equipment

Upload: gea-group

Post on 22-Jul-2016

230 views

Category:

Documents


1 download

DESCRIPTION

http://live.gea.com/global/en/binaries/Catalog-Hygienic-centrifugal-pumps-2015-03-EN_tcm11-13267.pdf

TRANSCRIPT

Page 1: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

GEA Tuchenhagen Hygienic Centrifugal PumpsBusiness Line Hygienic Pump Technology

Catalog 2014

engineering for a better world GEA Mechanical Equipment

Page 2: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

Publication date: 1/1/2014

The publication of specifications, technical data and information in written or electronic form does not release the user

from the responsibility of checking for themselves all products delivered by us for suitability for the application(s)

intended. These may be subject to change without prior notification. Errors and printing errors excepted - we assume

no liability for the correctness of specifications given.

The general sales terms and conditions for GEA Tuchenhagen GmbH.

All rights reserved - copyright on all contents:

GEA Tuchenhagen GmbH

Am Industriepark 2-10, 21514 Büchen, Germany

Registered Office: Büchen, Court of Registration: Lübeck, HRB 836 SB

Management office: Dipl.-Kfm. Franz Bürmann

Sales tax identification number: DE 812589019

Page 3: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

Standard TP

50 Hz

2-pole

50 Hz

4-pole

60 Hz

2-pole

60 Hz

4-pole

50 Hz

2-pole

60 Hz

2-pole

Options

Spare Parts

Standard TPS

Introduction 5 - 7Description of TP and TPS 8 - 9Overview of centrifugal pumps 10 - 11Performance characteristics, TP 50 Hz 12Performance characteristics, TP 60 Hz 13

Table of Contents Pages

Performance characteristics, TPS 50 Hz 102Performance characteristics, TPS 60 Hz 103Example of a TPS standard version 104 - 105TPS standard version 50 Hz, 2-poles 106 - 109

Options for TP and TPS series 116 - 119

Example of a TPS standard version 110 - 111TPS standard version 60 Hz, 2-poles 112 - 115

Example of a TP standard version 80 - 81TP standard version 60 Hz, 4-poles 82 - 101

Example of a TP standard version 58 - 59TP standard version 60 Hz, 2-poles 60 - 79

Example of a TP standard version 36 - 37TP standard version 50 Hz, 4-poles 38 - 57

Pumps - Checklist 121General Sales Terms and Conditions 122

Spare parts for TP and TPS series 120

Example of a TP standard version 14 - 15TP standard version 50 Hz, 2-poles 16 - 35

Page 4: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

4

GEA Tuchenhagen

Page 5: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

5

GEA Flow Components

Our Business Unit GEA Flow ComponentsOur main focus is on the growth and

further strengthening of our market

position as an internationally

recognized technology leader in

components for the food,

pharmaceutical and biotechnology

industries – mainly in the business

areas of valves, pumps and cleaning

technology.

Our four Business Lines – for erverything that flows

The GEA GroupEvery second litre of beer brewed in the world may well have flown througha component supplied by GEA Group. About every fourth litre of milk isextracted or further processed with equipment produced by GEA Group. One third of the worldwide instant coffee is produced in GEA Group systems – with sales of more than four billion euros, the groupis one of the largest suppliers of process machinery and technology in theworld.

GEA Group comprises four segments. The GEA Flow Components businessunit is part of the GEA Mechanical Equipment segment, together with thebusiness units Mechanical Separation, Food Solutions and Homogenizer.

The Business Unit GEA Flow Components

consists of: GEA Tuchenhagen in Büchen (Germany), GEA Aseptomag in Kirchberg(Switzerland) and GEA Breconcherry in the UK as well as various locationsin the USA, Canada, China, India, Poland and France

Hygienic Valve TechnologyGEA Tuchenhagen

Hygienic Pump TechnologyGEA Tuchenhagen

Cleaning TechnologyGEA Breconcherry

Aseptic Valve TechnologyGEA Aseptomag

Page 6: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

6

Business Line Hygienic Pumps

Our MissionGEA Tuchenhagen products meet the growing

demand for environmentally compatible

components. Our basis for this is a

future-oriented corporate and product concept

committed to economic efficiency,

sustainability and service-orientation.

Economically efficient The current generation of GEA Tuchenhagen®-VARIFLOWpumps provide users with considerable cost savings.

Sensibly rated high-efficiency motors in every dimension neededare available to cover the typical requirements of the markets.They enable that energy consumption is kept as low as possible,which means a positive impact on your profitability.

Hygienic designCarefully designed flow paths free from dead corners enableoptimum utilization of the conveying energy. The product isconveyed evenly and gently, resulting in a higher product quality, which provides the user with improved processing options and distribution potentials. The cleaning requirement isconsiderably reduced as far as time, water and resources are concerned, with a positive impact on production planning andcost accounting.

• High product quality

• Reduced consumption of energy, water and cleaning media

• Saves time in maintenance and cleaning

Economically

Page 7: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

7

Business Line Hygienic Pumps

Sustainable

Lower consumption of energy, water and chemicals means less load on environment and climate. For GEA Tuchenhagenusers, the future success of their business, and the continuingacceptance of their production site this aspect will become moreand more important.

On many markets, ecological criteria and the quality seals introduced for them increasingly determine retail assortmentplanning and what consumers will buy. Users of GEA Tuchenhagen products will not only be at anadvantage due to production processes which have proven to beenvironmentally friendly but also as a result of their maximumhygiene and care when processing their products.

This helps users to fulfil their own commitment to sustainableworking methods – the best way towards a secure future!

Service-oriented

Plant designers and engineering companies appreciate the benefits offered by GEA Tuchenhagen: they cannot only profitfrom a range of highly efficient products but also use the individually tailored engineering support available from GEA Tuchenhagen.

Maintenance service offers which protect your investment enable that the necessary service work on GEA Tuchenhagencomponents can be carried out with just minor interruptions inproduction processes individually tailored to the customer’srequirements.

Sustainable

• Less load on climate and environment

• Environmental orientation production methods

• Maximum hygiene and care in product processing

• Individual engineering support

• Life cycle cost calculations

• Minor production interruptions

• Tailor made service concepts

Service-orientated

Page 8: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

8

GEA Tuchenhagen®-VARIFLOW Centrifugal Pumps

The GEA Tuchenhagen®-VARIFLOW Centifugal Pump TP isdesigned for pumping demanding media up to a viscosity of1,000 mPas. Low flow velocities and gentle discharge of mediathrough the spiral housing ensure extremely gentle producthandling and high efficiency. 10 pump sizes with a capacity range of up to 210 m3/h andpump heads of up to 90 m w.c. are available, finely tuned to thetask at hand.

The spiral housing for the TP series is made of cold-rolled steel.This material has an excellent surface quality, which is essentialfor optimum cleaning in CIP/SIP processes. Wall thicknesses of6 mm provide high strength for critical piping configurationsand high inlet pressures.

• BreweriesBeer, wort, yeast, water, CIP solutions

• DairiesMilk, cream, yoghurt, whey, brine, CIP solutions

• FoodOils, sauces, stock, brine, flavours, ice-cream mix, CIP solutions

• Pharmaceuticals/CosmeticsUltra-pure water, extracts, emulsions, WFI water, distillates

• Fields of applications TPConveying, circulation, pressure boosting, filling lines, filling, emptying, filtration, evaporation, cleaning

• Fields of applications TPSCIP solutions, tank emptying, gas conveying

• Operating pressure max. 16 bar

• Low NPSH value avoids early cavitation to the pump

• The pumping characteristic can be adapted to the requirements of your system by speed control or impeller trimming

• Open impeller design

• All parts stainless steel, wetted components made of 1.4404 or 1.4409 (AISI 316L)

• Surface roughnesses of Ra ≤ 0.8 µm can be achieved bymechanical treatment of the surface (higher surface qualities on request)

• Driven by premium efficiency IE3 motors, design type IM B35, according to IEC

• Gentle product handling

• Standard connection: DIN 11853-2 Hygienic flange

• Low wear part stock requirement

• Acceptance test certification 3.1 (optional)

• EHEDG approved and certified

• Sealings comply to FDA and USP Class IV

By combining the existing TP series with an upstream screwrotor stage a new generation of hygienic self-priming centrifugalpumps has been created.

The GEA Tuchenhagen®-VARIFLOW Centrifugal Pump TPS isa self-priming pump for viscosities of up to 500 mPas. The pumpis used for CIP return applications, for emptying tanks as well asfor conveying products containing gas.The TPS is characterized by a low sound power level, highestefficiency and excellent cleaning properties. The TPS series alsopermits evacuation of pipes on the suction side – so that just onepump is required for CIP return and product conveying!

Applications

Technical benefits

Constructive characteristics

Special Features

Page 9: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

9

GEA Tuchenhagen®-VARIFLOW Centrifugal Pumps

FEM showing the seal ring inoperating mode

Sealing according to the VARIVENT® principleThe special groove enables the seal is kept reliably inplace at all times. The shape of the groove is based onFEM analyses. The metallic stop allows a defined compression of the seal, ensuring gap-free sealing against the product chamber without dead corners.

O-ring sealing between pumphousing and cover

Centrifugal Pump TP

Pump cover

Centrifugal Pump TPS

Clamp connection

Rotor housing cover

Circulation pipe

Front rotor

Rotor housing

Centrifugal Pump TP/TPS

Impeller

Mechanical seal

Sealing according to VARIVENT® principle

Pump housing

One-piece lantern

Pump shaft without key

Motor

2

4

43

9

5

6

7 9

8

1011

12

13

17 9

8

10

1112

13Centrifugal Pump TP

Centrifugal Pump TPS

1

2

3

4

5

6

7

8

9

10

11

12

13

Page 10: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

non self-priming

TP 1020 TP 1540 TP 2030 TP 2050 TP 2575 T T T T

10

GEA Tuchenhagen

max. flow rate [m³/h] 20 35 36 36 40 7 1 1 2 5

max. pump head [m] 24 42 36 60 85 6 7 9 4 3 6

Motor rating [kW], 2-pole 1.1 - 5.5 3.0 -15.0 1.5 - 11.0 3.0 - 15.0 5.5 - 30.0 3 7 1 1 2 3

max. flow rate [m³/h] 10 19 19 19 20 3 5 6 1 n n

max. pump head [m] 6 11 9 15 21 1 1 2 1 n n

Motor rating [kW], 4-pole 0.75 - 3.0 0.75 - 3.0 0.75 - 5.5 0.75 - 4.0 3.0 - 7.5 0 2 4 3 n

max. flow rate [m³/h] 24 44 44 42 48 8 1 1 2 6

max. pump head [m] 34 62 52 85 130 9 1 1 7 5 9

Motor rating [kW], 2-pole 1.25 - 5.5 3.0 - 15.0 1.5 - 11.0 3.0 - 15.0 5.5 - 30.0

max. flow rate [m³/h] 11 22 23 21 22

max. pump head [m] 8 15.5 13 22 31

Motor rating [kW], 4-pole 0.75 - 2.2 0.75 - 4.0 0.75 - 5.5 0.75 - 4.0 4.0 - 7.5

Impeller diameter [mm] 80 - 130 130 - 180 110 - 160 160 - 210 200 - 250

min. NPSH [m] (2,900 min-1) 1.0 1.0 1.0 1.0 1.0 0 1

max. viscosity [mPas] 1,000 1,000 1,000 1,000 1,000

4-pole, 50 Hz

2-pole, 50 Hz

4-pole, 60 Hz

2-pole, 60 Hz

GEA Tuchenhagen®-VARIFLOW Centrifugal Pumps, Series TP and TPS

Program overview

Page 11: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

non self-priming self-priming

T T T T TP 3050 TP 5060 TP 7060 TP 8080 TP 16040 TPS 2030 TPS 3050

11

GEA Tuchenhagen

2 3 3 75 75 110 120 210 32 52

4 3 6 65 75 74 90 49 37 64

1 3 3 5 3.0 - 22.0 5.5 - 30.0 7.5 - 30.0 11.0 - 37.0 11.0 - 45.0 2.2 - 11.0 3.0 - 22.0

1 1 1 36 40 55 65 100 n.a. n.a.

1 9 1 16 17 19 23 12 n.a. n.a.

0 0 0 3 0.75 - 7.5 2.2 - 7.5 2.2 - 7.5 4.0 - 7.5 3.0 - 7.5 n.a. n.a.

2 4 4 85 80 120 125 240 36 69

6 5 8 95 110 105 130 70 52 95

1 3 3 5 3.0 - 22.0 5.5 - 30.0 7.5 - 30.0 11.0 - 45.0 11.0 - 45.0 2.2 - 11.0 3.0 - 22.0

2 2 2 42 45 65 75 120 n.a. n.a.

1 1 2 24 24 27 34 17 n.a. n.a.

0 0 0 4 0.75 - 7.5 2.2 - 7.5 2.2 - 7.5 4.0 - 7.5 4.0 - 7.5 n.a. n.a.

8 1 1 1 2 140 - 210 155 - 225 155 - 225 180 - 250 160 - 200 110 - 160 140 - 210

1 1 1 1 0.8 0.9 1.0 1.2 3.8 0.8 0.8

1 1 1 1 1,000 1,000 1,000 1,000 1,000 500 500

GEA Tuchenhagen®-VARIFLOW Centrifugal Pumps, Series TP and TPS

Page 12: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

50 Hz

50 Hz12

GEA Tuchenhagen

Performance characteristics 50 Hz, GEA Tuchenhagen®-VARIFLOW, Series TP

4-pole (n = 1,450 min-1)

2-pole (n = 2,900 min-1)

TP 1540-4

1

20 30 40 50 100 200 30030

20

10

5

3

2

1

USGPM3002001005030 40

IGPM

H[m]

Q [m3/h]10 20 30 40 50 80

n = 1,450 min-1

100

400

400

TP 1540-4

TP 1020-4 TP 2030-4

TP 3050-4

TP 8080-4TP 2575-4

TP 5060-4

TP 16040-4

TP 2050-4 TP 7060-4

50

40

30

20

10

5

110 20 30 40 50

4

3

2

Q [m3/h]

n = 2,900 min-1

1

100

H[m]

100 200

8005004003002001005030 40USGPM

20 30 40 50 100 200 300 400 500 700IGPM

300

900

1000

TP 2050-2

TP 1540-2

TP 2030-2

TP 1020-2

TP 8080-2

TP 5060-2

TP 3050-2

TP 16040-2

TP 2575-2

TP 7060-2

Page 13: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

60 Hz

60 HzTP 2030-4

20

10

5

3

2

H[m]

2530

4020 30 40 50 100 200 300

USGPM4003002001005030 40

IGPM500

500 600

TP 5060-4

TP 1020-4

TP 1540-4

TP 2575-4

TP 3050-4

TP 8080-4

TP 16040-4

TP 2050-4

11 10 20 30 40 50

n = 1,750 min-1

Q [m3/h]100 140

TP 7060

13

Performance characteristics 60 Hz, GEA Tuchenhagen®-VARIFLOW, Series TP

GEA Tuchenhagen

8005004003002001005030 40USGPM

1 2 0 0

20 30 40 50 100 200 300 400 500 700IGPM

1 0 0 0

50

40

30

20

10

5

1

H[m]

100

150

1 10 20 30 40 50 70

Q [m3/h]

100 200 300

n = 3,500 min-1

TP 3050-2

TP 1540-2

TP 2030-2

TP 8080-2

TP 16040-2

TP2050-2

TP 1020-2

TP 2575-2TP 5060-2 TP 7060-2

4-pole (n = 1,750 min-1)

2-pole (n = 3,500 min-1)

Page 14: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

Standard version 2 pole/50Hz

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Depending on pump size

Mechanical seal Single-acting, material: C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Standard equipment Stainless steel protection hood and base frame with height-adjustable

calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F, incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 210 m3/h

Pump head max. 90 m w.c.

14

GEA Tuchenhagen

Standard version, centrifugal pump type TP, 2-poles (n=2,900 min-1), 50 Hz

50

40

30

20

10

5

110 20 30 40 50

4

3

2

Q [m3/h]

n = 2,900 min-1

1

100

H[m]

100 200

8005004003002001005030 40USGPM

20 30 40 50 100 200 300 400 500 700IGPM

300

900

1000

TP 2050-2

TP 1540-2

TP 2030-2

TP 1020-2

TP 8080-2

TP 5060-2

TP 3050-2

TP 16040-2

TP 2575-2

TP 7060-2

Performance characteristicsTP

TP 1020 TP 1540 bis TP8080 TP 16040

Page 15: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

1. Type TP010202. Speed 2 = 2 pole3. Frequency 50 = 50 Hz4. Impeller 080 = 80 mm 100 = 100 mm 120 = 120 mm 090 = 90 mm 110 = 110 mm 130 = 130 mm5. Motor power 011 = 1.1 kW (IEC 80) 015 = 1.5 kW (IEC 90S) 022 = 2.2 kW (IEC 90L) 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 112M)

15

Example of a standard selection

GEA Tuchenhagen

Standard TP

50 Hz

2-pole

Standard TPS50 Hz50 Hz0

22

18

8

6

4

2

NPSH[m]

0

[ft]

1

1.0

2.5

3.5

0

Q [m3/h]

70

60

50

40

30

20

0

4.0

2.0

0

1.0

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

3.0

18

19

19

20

20

17 18

0.5

2.0

3.0

Q [m3/h]

16

14

12

10

20

24

10

80

P[kW][hp]

00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

1.0

18 19 20

0.8

0.6

0.4

0.2

1.2

0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

Q [m3/h]

1.4

1.6

1.8

2.0

H

[m][ft]USGPM

0 10 20 30 40 50 60 70

0 10 20 30 40 50 60

80

70

η 0.45

η 0.50

η 0.35η 0.30η 0.40

IGPMη 0.25

Ø80

Ø90

Ø100

Ø110

Ø120

Ø130

Ø80

Ø90

Ø100

Ø110

Ø120

Ø130

Ø130Ø80

Performence curves, centrifugal pump, TP 1020 (2-pole / 50 Hz)

Selected valuesdetermined by thepump selected

Selection using thecharacteristic curves

TP01020250080

011

Designation Code of selection characteristicsPosExample

Impeller diameter

Required motor power

Required NPSH-value

Motor output selection inaccordance with capacity

and pump head

Impeller selection inaccordance with capacity

and pump head

Standard version, for other versions see options

PositionND654

01 0 2 0 2253

0PT1

Code 085 0N

7F K 0 4 0

9 10E K E - 1

111213-14

J15

J16

-17

Page 16: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

16

GEA Tuchenhagen

Standard version, centrifugal pump, type TP 1020, 2-pole (n=2,900 min-1), 50 Hz

All dimensions in mm

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 20 m³/h

Pump head max. 24 m w.c.

Housing pressure max. 10 bar

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 10202. Speed 2 = 2 pole3. Frequency 50 = 50 Hz4. Impeller 080 = 80 mm 100 = 100 mm 120 = 120 mm 090 = 90 mm 110 = 110 mm 130 = 130 mm5. Motor power 011 = 1.1 kW (IEC 80) 015 = 1.5 kW (IEC 90S) 022 = 2.2 kW (IEC 90L) 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 112M)

TP01020250080

011

Designation Code of selection characteristicsPosExample

PositionND654

01 0 2 0 2253

0PT1

Code 085 0N

7F K 0 4 0

9 10E K E - 1

111213-14

J15

J16

-17

TP 1020Motor size b c** d f h m n p t* u v w x y*

80 484 390 144 285 352 76 228 125 25.5 92 125 82 14 25.590S / 90L 490 425 144 285 352 76 228 140 25.5 90 125 82 14 25.5

100L / 112M 602 474/496 154 335 403 76 278 160 25.5 112 125 85 14 25.5

Page 17: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

17

Performance curves, centrifugal pump, type TP 1020, 2-pole (n=2,900 min-1), 50 Hz

GEA Tuchenhagen

Standard TP

50 Hz

2-pole

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

50 Hz50 Hz0

22

18

8

6

4

2

NPSH[m]

0

[ft]

1

1.0

2.5

3.5

0

Q [m3/h]

70

60

50

40

30

20

0

4.0

2.0

0

1.0

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

3.0

18

19

19

20

20

17 18

0.5

2.0

3.0

Q [m3/h]

16

14

12

10

20

24

10

80

P[kW][hp]

00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

1.0

18 19 20

0.8

0.6

0.4

0.2

1.2

0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

Q [m3/h]

1.4

1.6

1.8

2.0

H

[m][ft] USGPM0 10 20 30 40 50 60 70

0 10 20 30 40 50 60

80

70

η 0.45

η 0.50

η 0.35η 0.30η 0.40

IGPMη 0.25

Ø80

Ø90

Ø100

Ø110

Ø120

Ø130

Ø80

Ø90

Ø100

Ø110

Ø120

Ø130

Ø130Ø80

Page 18: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

18

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 1540, 2-pole (n=2,900 min-1), 50 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 15402. Speed 2 = 2 pole3. Frequency 50 = 50 Hz4. Impeller 130 = 130 mm 140 = 140 mm 145 = 145 mm 150 = 150 mm 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm5. Motor power 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 112M) 075 = 7.5 kW (IEC 112M) 092 = 9.0 kW (IEC 132M) 110 = 11.0 kW (IEC 132M) 150 = 15.0 kW (IEC 132M)

TP01540250130

30

Designation Code of selection characteristicsPosExample

PositionND654

01 5 4 0 2253

0PT1

Code 086 5N

7F K 0 4 0

9 10E K E - 1

111213-14

J15

J16

-17

TP 1540Motor size b c** d f h m n p t* u v w x y*100L 608 480 152 335 403 90 278 160 25.5 112 140 85 42 25.5

112M (4 kW + 5.5 kW) 608 502 131.5 335 403 90 278 190 25.5 112 140 85 42 25.5112M (7.5 kW) 608 524 131.5 335 403 90 278 190 25.5 112 140 85 42 25.5

132M (9.0 kW + 11 kW) 709 619 152 410 444 90 332 216 25.5 132 140 85 42 25.5132M (15 kW) 709 670 152 410 444 90 332 216 25.5 132 140 85 42 25.5

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 40

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 35 m³/h

Pump head max. 42 m w.c.

Housing pressure max. 16 bar

Page 19: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

19

GEA Tuchenhagen

Standard TP

50 Hz

2-pole

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 1540, 2-pole (n=2,900 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

50 Hz50 Hz

H

44

40

36

32

28

24

20

16

12

8

4

[m][ft]

NPSH[m]

P[kW]

USGPM0

0

[ft]

0

1

2

3

0

20 40 60 80 100 120 140

0 20 40 60 80 100 120

140

120

100

80

60

40

20

0

0

160

140

5 10 15 20 25 30 35Q [m3/h]

40

0 5 10 15 20 25 30 35Q [m3/h]

40

[hp]

10

15

20

1.0

1.5

2.0

2.5

3.0

3.5

4.0

0 5 10 15 20 25 30 35Q [m3/h]

40

4.5

5.0

5.5

6.0

6.5

1

2

3

4

55

6

7

8

IGPM

4

5

6

Ø 1 3 0

Ø 1 4 0

Ø 1 5 0

Ø 1 6 0

Ø 1 7 0

Ø 1 8 0

η 0.57

η 0.55

η 0.45

η 0.35

η 0.30

Ø 1 3 0 Ø 1 8 0

η 0.40

η 0.50

5

Ø 1 8 0

Ø 1 7 0

Ø 1 6 0

Ø 1 5 0

Ø 1 4 0

Ø 1 3 0

Page 20: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

20

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 2030, 2-pole (n=2,900 min-1), 50 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 20302. Speed 2 = 2 pole3. Frequency 50 = 50 Hz4. Impeller 110 = 110 mm 120 = 120 mm 130 = 130 mm 140 = 140 mm 145 = 145 mm 150 = 150 mm 155 = 155 mm 160 = 160 mm5. Motor power 015 = 1.5 kW (IEC 90S) 022 = 2.2 kW (IEC 90L) 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 112M) 075 = 7.5 kW (IEC 112M) 092 = 9.0 kW (IEC 132M) 110 = 11.0 kW (IEC 132M)

TP02030250110

015

Designation Code of selection characteristicsPosExample

PositionND654

02 0 3 0 2253

0PT1

Code 085 0N

7F K 0 5 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 36 m³/h

Pump head max. 36 m w.c.

Housing pressure max. 16 bar

TP 2030Motor size b c** d f h m n p t* u v w x y*90S / 90L 494 429 121.5 285 352 85 228 140 25.5 90 135 82 40 25.5100L 606 478 131.5 335 403 85 278 160 25.5 112 135 85 40 25.5

112M (4 kW + 5.5 kW) 606 500 131.5 335 403 85 278 190 25.5 112 135 85 40 25.5112M (7.5 kW) 606 522 131.5 335 403 85 278 190 25.5 112 135 85 40 25.5

132M 707 617 152 410 444 85 332 216 25.5 132 135 85 40 25.5

Page 21: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

21

GEA Tuchenhagen

Standard TP

50 Hz

2-pole

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 2030, 2-pole (n=2,900 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

50 Hz50 Hz

H

44

40

36

32

28

24

20

16

12

8

4

[m][ft]

NPSH[m]

[kW]

1.0

1.5

2.0

2.5

3.0

3.5

4.0

USGPM0

0

[ft]

0

1

2

3

0

0 5 10 15 20 25 30 35Q [m3/h]

20 40 60 80 100 120 140

0 20 40 60 80 100 120

140

120

100

80

60

40

20

0

40

160

140

5 10 15 20 25 30 35Q [m3/h]

40

0 5 10 15 20 25 30 35Q [m3/h]

40

4.5

5.0

4

5

10

0

5

15

2.0

3.0

4.0

5.0

6.0

[hp]P

20

1.0

6

Ø160

Ø150

Ø140

Ø130

Ø120

IGPM

Ø110

Ø160

Ø150

Ø140

Ø130

Ø120

η 0.60

η 0.50η 0.45η 0.40η 0.35η 0.30

Ø110

Ø110 Ø160

η 0.55

Page 22: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

22

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 2050, 2-pole (n=2,900 min-1), 50 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 20502. Speed 2 = 2 pole3. Frequency 50 = 50 Hz4. Impeller 160 = 160 mm 170 = 170 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm5. Motor power 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 112M) 075 = 7.5 kW (IEC 112M) 092 = 9.0 kW (IEC 132M) 110 = 11.0 kW (IEC 132M) 150 = 15.0 kW (IEC 132M)

TP02050250160

030

Designation Code of selection characteristicsPosExample

PositionND654

02 0 5 0 2253

0PT1

Code 086 5N

7F K 0 5 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 36 m³/h

Pump head max. 60 m w.c.

Housing pressure max. 16 bar

TP 2050Motor size b c** d f h m n p t* u v w x y*100L 622 494 136 335 403 107 278 160 25.5 112 161 85 52 25.5

112M (4 kW + 5.5 kW) 622 516 136 335 403 107 278 190 25.5 112 161 85 52 25.5112M (7.5 kW) 622 538 136 335 403 107 278 190 25.5 112 161 85 52 25.5

132M (9.0 kW + 11 kW) 723 633 156 410 444 107 332 216 25.5 132 161 85 52 25.5132M (15 kW) 723 684 156 410 444 107 332 216 25.5 132 161 85 52 25.5

Page 23: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

23

GEA Tuchenhagen

Standard TP

50 Hz

2-pole

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 2050, 2-pole (n=2,900 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

0 5 10 15 20 25 30 35

0 5 10 15 20 25 30 35

50 Hz50 Hz

[m]

P[kW]

0

5

10

0

1

2

0 5 10 15 20 25 30 35

5

0

Q [m3/h]

Q [m3/h]0

5

10

12.5

[hp]

NPSH[ft]

0

10

20

30

40

50

60

70250

200

150

100

50

0

Q [m3/h]

H[m][ft] USGPM

0 25 50 75 100 125 150

1251007550250 IGPM

10 3

2.5

7.5

2.5

7.5

Ø 2 0 0

Ø 1 7 5 η 0.50

η 0.52

η 0.45

Ø 1 6 0

Ø 2 1 0

η 0.45

η 0.52η 0.50

η 0.40

Ø190Ø180

Ø170Ø160

Ø200

Ø210

Ø160

Ø 1 9 0

Ø 1 8 0Ø 1 7 0

Ø210

η 0.45η 0.45η 0.40

2.5

7.52.5

1.5

0.5

Page 24: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

24

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 2575, 2-pole (n=2,900 min-1), 50 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 25752. Speed 2 = 2 pole3. Frequency 50 = 50 Hz4. Impeller 200 = 200 mm 210 = 210 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm 230 = 230 mm 235 = 235 mm 240 = 240 mm 245 = 245 mm 250 = 250 mm5. Motor power 055 = 5.5 kW (IEC 112M) 075 = 7.5 kW (IEC 112M) 092 = 9.0 kW (IEC 132M) 110 = 11.0 kW (IEC 132M) 150 = 15.0 kW (IEC 132M) 185 = 18.5 kW (IEC 160L) 220 = 22.0 kW (IEC 160L) 300 = 30.0 kW (IEC 200L)

TP02575250200

055

Designation Code of selection characteristicsPosExample

PositionND654

02 5 7 5 2253

0PT1

Code 086 5N

7F K 0 5 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 40 m³/h

Pump head max. 85 m w.c.

Housing pressure max. 16 bar

TP 2575

Motor size b c** d f h m n p t* u v w x y*

112M (5.5 kW / 7.5 kW) 621 515/537 138 335 403 124.5 278 190 25.5 112 190 85 48.5 25.5132M (9.0 kW + 11 kW) 720 630 156 410 444 107 332 216 25.5 132 190 85 48.5 25.5

132M (15 kW) 720 681 156 410 444 107 332 216 25.5 132 190 85 48.5 25.5160L 894 782 191 640 598 124.5 412 254 25.5 160 190 110 48.5 25.5200L 1,033 908 200.5 810 668 124.5 472 318 25.5 200 190 115 48.5 25.5

Page 25: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

25

GEA Tuchenhagen

Standard TP

50 Hz

2-pole

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 2575, 2-pole (n=2,900 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

50 Hz50 Hz

H

92

80

72

64

56

48

40

32

24

8

[m][ft]

NPSH[m]

[kW]

0

2

4

6

8

10

12

USGPM0

0

[ft]

0

1

0

0 5 10 15 20 25 30 35Q [m3/h]

20 40 60 80 100 120 140

0 20 40 60 80 100 120

280

240

200

80

40

0

40

160

140

5 10 15 20 25 30 35Q [m3/h]

40

0 5 10 15 20 25 30 35Q [m3/h]

40

14

16

2

0

5

7.5

4.0

8.0

[hp]P

10 3

16

160

120

160

180

45

450

12

16

20

2.5

45

IGPM

Ø200Ø250

Ø250

Ø240

Ø230Ø220

Ø210Ø200

Ø250

Ø240

Ø230

Ø220

Ø210

Ø200

η 0.35η 0.44

η 0.48

η 0.46η 0.46

η 0.40

η 0.44

η 0.35η 0.40

η 0.44

Page 26: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

26

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 3050, 2-pole (n=2,900 min-1), 50 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 30502. Speed 2 = 2 pole3. Frequency 50 = 50 Hz4. Impeller 140 = 140 mm 150 = 150 mm 160 = 160 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm5. Motor power 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 112M) 075 = 7.5 kW (IEC 112M) 092 = 9.0 kW (IEC 132M) 110 = 11.0 kW (IEC 132M) 150 = 15.0 kW (IEC 132M) 185 = 18.5 kW (IEC 160L) 220 = 22.0 kW (IEC 160L)

TP03050250140

030

Designation Code of selection characteristicsPosExample

PositionND654

03 0 5 0 2253

0PT1

Code 086 5N

7F K 0 5 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 75 m³/h

Pump head max. 65 m w.c.

Housing pressure max. 16 bar

TP 3050

Motor size b c** d f h m n p t* u v w x y*

100L 618 504 134 335 403 103 278 160 25.5 112 155 85 50 25.5112M (4 kW + 5.5 kW) 618 515 134 335 403 103 278 190 25.5 112 155 85 50 25.5

112M ( 7.5 kW) 618 534 134 335 403 103 278 190 25.5 112 155 85 50 25.5132M (9.0 kW + 11 kW) 719 629 154 410 444 103 332 216 25.5 132 155 85 50 25.5

132M (15 kW) 719 680 154 410 444 103 332 216 25.5 132 155 85 50 25.5160L 893 781 189 640 598 103 412 254 25.5 160 155 110 50 25.5

Page 27: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

27

GEA Tuchenhagen

Standard TP

50 Hz

2-pole

Standard TPS

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 3050, 2-pole (n=2,900 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

50 Hz50 Hz

[m]

P[kW]

0

5

10

15

20

00 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85

1

2

3

4

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85

15

10

5

0

Q [m3/h]

Q [m3/h]

0

5

10

15

20

25

[hp]

NPSH[ft]

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 850

10

20

30

40

50

60

70

250

200

150

100

50

0

Q [m3/h]

H

[m][ft]USGPM

0 50 100 150 200 250 300 350

300250200150100500 IGPM

20

5

6

Ø210

Ø200

Ø190

Ø140

Ø180Ø170

Ø 2 0 0

Ø 1 9 0

Ø 1 7 5

η 0.50η 0.55

η 0.45

η 0.61

Ø 1 8 0

Ø 1 7 0

Ø 1 6 0

Ø 1 5 0

Ø 2 1 0

Ø 2 1 0

Ø 1 4 0

Ø 1 4 0

η 0.45η 0.40

η 0.60

η 0.60

η 0.50 η 0.55η 0.40

Ø160Ø150

Impeller diameter

Page 28: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

28

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 5060, 2-pole (n=2,900 min-1), 50 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 50602. Speed 2 = 2 pole3. Frequency 50 = 50 Hz4. Impeller 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm5. Motor power 055 = 5.5 kW (IEC 112M) 075 = 7.5 kW (IEC 112M) 092 = 9.0 kW (IEC 132M) 110 = 11.0 kW (IEC 132M) 150 = 15.0 kW (IEC 132M) 185 = 18.5 kW (IEC 160L) 220 = 22.0 kW (IEC 160L) 300 = 30.0 kW (IEC 200L)

TP05060250175

055

Designation Code of selection characteristicsPosExample

PositionND654

05 0 6 0 2253

0PT1

Code 088 0N

7F K 0 6 5

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 75 m³/h

Pump head max. 75 m w.c.

Housing pressure max. 16 bar

TP 5060

Motor size b c** d f h m n p t* u v w x y*

112M (5.5 kW / 7.5 kW) 622 517/538 137 335 403 114.5 278 190 27.5 112 230 85 51 25.5132M (9.0 kW + 11 kW) 723 633 157 410 444 114.5 332 216 27.5 132 230 85 51 25.5

132M (15 kW) 723 684 157 410 444 114.5 332 216 27.5 132 230 85 51 25.5160L 897 785 192 640 598 114.5 412 254 27.5 160 230 110 52 25.5200L 1,030 905 195 810 673 114.5 472 318 27.5 200 230 115 52 25.5

Page 29: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

29

GEA Tuchenhagen

Standard TP

50 Hz

2-pole

Standard TPS

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 5060, 2-pole (n=2,900 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

50 Hz50 HzNPSH

[m]

P[kW]

0

5

10

15

20

0

[ft]

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 850

10

20

30

40

50

60

70

80

90

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85

1

2

3

4

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85

300

250

200

150

100

50

0

15

10

5

0

Q [m3/h]

Q [m3/h]

Q [m3/h]

H

[m][ft] USGPM0 50 100 150 200 250 300 350

300250200150100500

0

5

10

15

20

25

[hp]30

5

IGPM

Ø 1 7 5

Ø 1 8 5

Ø 1 9 5

Ø 2 0 5

Ø 2 1 5

Ø 2 2 5η 0.45

η 0.50 η 0.55

η 0.62

η 0.45

η 0.55

η 0.50

Ø175

Ø185

Ø195Ø205

Ø215Ø225

Ø 2 2 5

Ø 1 6 5

η 0.40η 0.58

η 0.40

η 0.58

Ø 1 5 5

Ø 1 5 5

Ø165Ø155

Impeller diameter

Page 30: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

30

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 7060, 2-pole (n=2,900 min-1), 50 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 70602. Speed 2 = 2 pole3. Frequency 50 = 50 Hz4. Impeller 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm5. Motor power 075 = 7.5 kW (IEC 112M) 092 = 9.0 kW (IEC 132M) 110 = 11.0 kW (IEC 132M) 150 = 15.0 kW (IEC 132M) 185 = 18.5 kW (IEC 160L) 220 = 22.0 kW (IEC 160L) 300 = 30.0 kW (IEC 200L)

TP07060250175

075

Designation Code of selection characteristicsPosExample

PositionND654

07 0 6 0 2253

0PT1

Code 088 0N

7F K 0 6 5

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 110 m³/h

Pump head max. 74 m w.c.

Housing pressure max. 16 bar

TP 7060

Motor size b c** d f h m n p t* u v w x y*

112M 622 538 132 335 427 110 278 190 27.5 112 230 85 56 25.5132M (9.0 kW + 11 kW) 723 633 152 410 444 110 332 216 27.5 132 230 85 56 25.5

132M (15 kW) 723 684 152 410 444 110 332 216 27.5 132 230 85 56 25.5160L 897 785 187 640 596 110 412 254 27.5 160 230 110 56 25.5200L 1,030 905 190.5 810 668 110 472 318 27.5 200 230 115 56 25.5

Page 31: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

31

GEA Tuchenhagen

Standard TP

50 Hz

2-pole

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 7060, 2-pole (n=2,900 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

50 Hz50 Hz

H

80

70

60

50

40

30

20

10

[m][ft]

NPSH[m]

P

0

USGPM100

0

1

2

3

4

5

[ft]

0 10 20 30 40 50 60 70 80 90 100 110 120 1300

0 10 20 30 40 50 60 70 80 90 100 110 120 130

5

10

15

20

0 10 20 30 40 50 60 70 80 90 100 110 120 130

200 300 400 5000

0 100 200 300 400

250

200

150

100

50

0

15

10

5

0

Q [m3/h]

Q [m3/h]

Q [m3/h]

[hp]

0

5

10

15

20

25

[kW]

25

30

30

35

20

IGPM

Ø 1 5 5 Ø 2 2 5

Ø 1 9 5

Ø225

Ø215

Ø205

Ø185

Ø175Ø165

Ø 1 5 5

Ø 2 2 5

Ø 2 0 5

Ø 2 1 5

Ø 1 9 5

Ø 1 8 5Ø 1 7 5Ø 1 6 5

Ø 1 5 5

η 0.66

η 0.65

η 0.60η 0.55

η 0.60η 0.55

η 0.50

η 0.50

Page 32: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

32

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 8080, 2-pole (n=2,900 min-1), 50 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 80802. Speed 2 = 2 pole3. Frequency 50 = 50 Hz4. Impeller 180 = 180 mm 190 = 190 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm 230 = 230 mm 235 = 235 mm 240 = 240 mm 245 = 245 mm 250 = 250 mm5. Motor power 110 = 11.0 kW (IEC 132M) 150 = 15.0 kW (IEC 132M) 185 = 18.5 kW (IEC 160L) 220 = 22.0 kW (IEC 160L) 300 = 30.0 kW (IEC 200L) 370 = 37.0 kW (IEC 200L) 450 = 45.0 kW (IEC 225M)

TP08080250180

110

Designation Code of selection characteristicsPosExample

PositionND654

08 0 8 0 2253

0PT1

Code 180 0N

7F K 0 6 5

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 100; Pressure port (DS), DN 65

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 120 m³/h

Pump head max. 90 m w.c.

Housing pressure max. 16 bar

TP 8080

Motor size b c** d f h m n p t* u v w x y*

132M (11 kW / 15 kW) 742 652/703 156 410 444 124 332 216 27.5 132 250 85 71 25.5160L 916 804 191 640 598 124 412 254 27.5 160 250 110 71 25.5200L 1,050 925 195 810 668 124 472 318 27.5 200 250 115 71 25.5225M 1,076 961 195 810 720 124 472 356 27.5 200 250 115 71 25.5

Page 33: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

33

GEA Tuchenhagen

Standard TP

50 Hz

2-pole

Standard TPS

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 8080, 2-pole (n=2,900 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

50 Hz50 Hz

H

110

100

90

80

70

60

50

40

30

20

10

[m][ft]

NPSH[m]

P

0

USGPM100

0

1

2

3

4

5

[ft]

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 1500

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

10

20

30

40

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

200 300 400 5000 600

0 100 200 300 400 500

350

300

250

200

150

100

50

0

15

10

5

0

Q [m3/h]

Q [m3/h]

Q [m3/h]

[hp]

0

10

20

30

40

50

[kW]

IGPM

η 0.50

Ø 2 5 0

Ø 2 0 0

Ø 2 1 0

Ø 2 2 0

Ø 2 3 0

Ø 2 4 0

Ø 1 9 0Ø 1 8 0

Ø 1 8 0Ø 2 5 0

Ø 1 8 0

Ø250Ø240

Ø230Ø220

Ø210

Ø200Ø 1 9 0

η 0.66

η 0.64

η 0.60

η 0.55

η 0.60η 0.55η 0.50η 0.45η 0.40

Impeller diameter

Page 34: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

34

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 16040, 2-pole (n=2,900 min-1), 50 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 160402. Speed 2 = 2 pole3. Frequency 50 = 50 Hz4. Impeller 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 5. Motor power 110 = 11.0 kW (IEC 132M) 150 = 15.0 kW (IEC 132M) 185 = 18.5 kW (IEC 160L) 220 = 22.0 kW (IEC 160L) 300 = 30.0 kW (IEC 200L) 370 = 37.0 kW (IEC 200L) 450 = 45.0 kW (IEC 225M)

TP16040250160

110

Designation Code of selection characteristicsPosExample

PositionND654

06 0 4 0 2253

1PT1

Code 185 0N

7F K 1 0 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 150; Pressure port (DS), DN 100

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 210 m³/h

Pump head max. 49 m w.c.

Housing pressure max. 16 bar

TP 16040

Motor size b c** d f h m n p t* u v w x y*

132M (11 kW / 15 kW) 752 662/713 151 410 444 108 332 216 29.5 132 280 85 86 27.5160L 926 814 186 640 596 108 412 254 29.5 160 280 110 86 27.5200L 1,059 934 189 810 668 108 472 318 29.5 200 280 115 86 27.5225M 1,085 970 189 810 720 108 521 356 29.5 225 280 115 86 27.5

Page 35: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

35

GEA Tuchenhagen

Standard TP

50 Hz

2-pole

Standard TPS

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 16040, 2-pole (n=2,900 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210

10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210

50 Hz50 Hz0

45

5

NPSH[m]

0

[ft]

4

8

12

0

Q [m3/h]

80

60

40

0

40

20

0

10

0

30

2

6

10

Q [m3/h]

40

35

30

25

50

20

P[kW[hp]

00

20

15

10

5

25

0

5

10

15

20

25

30

35

40

Q [m3/h]

30

3545

H

[m][ft]

10 20 30 40 50 60 70 80 90 110100 120 130 140 150 160 170 180 190 200

20

15

10

0

0 IGPM

100 300 400 500 600 700

900800700600500400300200

100

120

140

160

210

USGPM100

200

η 0.50

Ø160

Ø170

Ø200

Ø170

Ø180

Ø190

Ø200

Ø200

Ø160

Ø160

Ø190

Ø180

η 0.55

η 0.60

η 0.65

η 0.67η 0.65

η 0.60η 0.55η 0.50

η 0.45η 0.45

Impeller diameter

Page 36: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

Standard version 4 pole/50Hz

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Depending on pump size

Mechanical seal Single-acting, material: C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Standard equipment Stainless steel protection hood and base frame with height-adjustable

calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F, incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 100 m3/h

Pump head max. 23 m w.c.

Standard version, centrifugal pump, type TP, 4-pole (n=1,450 min-1), 50 Hz

36

GEA Tuchenhagen

TP 1540-4

1

20 30 40 50 100 200 30030

20

10

5

3

2

1

USGPM3002001005030 40

IGPM

H[m]

Q [m3/h]10 20 30 40 50 80

n = 1,450 min-1

100

400

400

TP 1540-4

TP 1020-4 TP 2030-4

TP 3050-4

TP 8080-4TP 2575-4

TP 5060-4

TP 16040-4

TP 2050-4 TP 7060-4

Performance characteristicsTP

TP 1020 TP 1540 bis TP8080 TP 16040

Page 37: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

Example of a standard selection

37

GEA Tuchenhagen

Standard TP 50 Hz

4-pole

Standard TPS

1. Type TP010202. Speed 4 = 4 pole3. Frequency 50 = 50 Hz4. Impeller 080 = 80 mm 100 = 100 mm 120 = 120 mm 090 = 90 mm 110 = 110 mm 130 = 130 mm5. Motor power 007 = 0.75 kW (IEC 80) 011 = 1.1 kW (IEC 90S) 015 = 1.5 kW (IEC 90L) 022 = 2.2 kW (IEC 100L) 030 = 3.0 kW (IEC 100L)

50 Hz50 Hz0

2

1

NPSH[m]

P[kW]

0

0

[ft]

0.5

1.0

1.5

0

Q [m3/h]

15

10

5

0

4.0

2.0

0

1.0

1 2 3 4 5 6 7 8

0 1 2 3 4 5 6 7 8

0 1 2 3 4 5 6 7 8

3.0

9

9

10

10

10

0.1

9

0.2

[hp]

0

0.1

Q [m3/h]

Q [m3/h]

4

3

5

620

H

[m][ft] USGPM0 5 10 15 20 25 30 35

0 5 10 15 20 25 30

40

35

0.2

0.3

η 0.45

η 0.50

η 0.35η 0.30η 0.40

IGPM

η 0.25Ø130

Ø130

Ø120

Ø120

Ø110

Ø110

Ø100

Ø90

Ø90

Ø80

Ø80

Ø80 Ø130

Performance curves, centrifugal pump, TP 1020 (4-polig / 50 Hz)

Selected valuesdetermined by thepump selected

Selection using thecharacteristic curves

TP01020450080

007

Designation Code of selection characteristicsPosExample

Impeller diameter

Required motor power

Required NPSH-value

Motor output selection inaccordance with capacity

and pump head

Impeller selection inaccordance with capacity

and pump head

Standard version, for other versions see options

PositionND654

01 0 2 0 4253

0PT1

Code 085 0N

7F K 0 4 0

9 10E K E - 1

111213-14

J15

J16

-17

Page 38: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

38

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 1020, 4-pole (n=1,450 min-1), 50 Hz

TP 1020 Motor size b c** d f h m n p t* u v w x y*

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

80 484 390 144 285 352 76 228 125 25.5 92 125 82 14 25.5

90S / 90L 490 425 144 285 352 76 228 140 25.5 90 125 82 14 25.5

100L (2.2 kW / 3 kW) 602 474/489 154 335 403 76 278 160 25.5 112 125 85 14 25.5

1. Type TP 10202. Speed 4 = 4 pole3. Frequency 50 = 50 Hz4. Impeller 080 = 80 mm 100 = 100 mm 120 = 120 mm 090 = 90 mm 110 = 110 mm 130 = 130 mm5. Motor power 007 = 0.75 kW (IEC 80) 011 = 1.1 kW (IEC 90S) 015 = 1.5 kW (IEC 90L) 022 = 2.2 kW (IEC 100L) 030 = 3.0 kW (IEC 100L)

TP01020450080

007

Designation Code of selection characteristicsPosExample

PositionND654

01 0 2 0 4253

0PT1

Code 085 0N

7F K 0 4 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 10 m³/h

Pump head max. 6 m w.c.

Housing pressure max. 10 bar

Page 39: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

39

GEA TuchenhagenImpeller diameter

Required motor power

Required NPSH-value

Standard TP

Standard TPS

Performance curves, centrifugal pump, type TP 1020, 4-pole (n=1,450 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

50 Hz50 Hz0

2

1

NPSH[m]

P[kW]

0

0

[ft]

0.5

1.0

1.5

0

Q [m3/h]

15

10

5

0

4.0

2.0

0

1.0

1 2 3 4 5 6 7 8

0 1 2 3 4 5 6 7 8

0 1 2 3 4 5 6 7 8

3.0

9

9

10

10

10

0.1

9

0.2

[hp]

0

0.1

Q [m3/h]

Q [m3/h]

4

3

5

620

H

[m][ft]USGPM

0 5 10 15 20 25 30 35

0 5 10 15 20 25 30

40

35

0.2

0.3

η 0.45

η 0.50

η 0.35η 0.30η 0,40

IGPMη 0.25Ø130

Ø130

Ø120

Ø120

Ø110

Ø110

Ø100

Ø90

Ø90

Ø80

Ø80

Ø80 Ø130

50 Hz

4-pole

Page 40: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

40

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 1540, 4-pole (n=1,450 min-1), 50 Hz

TP 1540 Motor size b c** d f h m n p t* u v w x y*

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

80 490 396 121.5 285 352 90 228 125 25.5 92 140 82 42 25.5

90S / 90L 496 431 121.5 285 352 90 228 140 25.5 90 140 82 42 25.5

100L (2.2 kW / 3 kW) 608 480/495 131.5 335 403 90 278 160 25.5 112 140 85 42 25.5

1. Type TP 15402. Speed 4 = 4 pole3. Frequency 50 = 50 Hz4. Impeller 130 = 130 mm 140 = 140 mm 145 = 145 mm 150 = 150 mm 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm5. Motor power 007 = 0.75 kW (IEC 80) 011 = 1.1 kW (IEC 90S) 015 = 1.5 kW (IEC 90L) 022 = 2.2 kW (IEC 100L) 030 = 3.0 kW (IEC 100L)

TP01540450130

007

Designation Code of selection characteristicsPosExample

PositionND654

01 5 4 0 4253

0PT1

Code 086 5N

7F K 0 4 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 40

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 19 m³/h

Pump head max. 11 m w.c.

Housing pressure max. 16 bar

Page 41: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

41

GEA Tuchenhagen

Standard TP

Standard TPS

Performance curves, centrifugal pump, type TP 1540, 4-pole (n=1,450 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

1

50 Hz50 Hz0

11

10

9

8

7

6

5

4

3

2

1

NPSH[m]

P

[kW]

0

0

[ft]

10

Q [m3/h]

35

30

25

20

15

10

5

02 3 4 5 6 7 8 9 10 11 12 13 14 15 16

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

18

18

19

19

19

20

20

20

17 18

5

2

3

4

[hp]

H

[m][ft]USGPM

0 10 20 30 40 50 60 70

0 10 20 30 40 50 60

80

70

Q [m3/h]

Q [m3/h]

10

15

20

0

00.1

Ø 1 3 0

Ø 1 4 0

Ø 1 5 0

Ø 1 6 0

Ø 1 7 0

Ø 1 8 0

η 0.57

η 0.55

η 0.50η 0.45η 0.35η 0.30 η 0.40

Ø 1 3 0 Ø 1 8 0

Ø 1 8 0

Ø 1 7 0Ø 1 6 0

Ø 1 5 0Ø 1 4 0

Ø 1 3 0

IGPM

0.20.30.40.50.60.70.80.91.01.11.2

5

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

Impeller diameter

Required NPSH-value

Required motor power

50 Hz

4-pole

Page 42: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

42

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 2030, 4-pole (n=1,450 min-1), 50 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 20302. Speed 4 = 4 pole3. Frequency 50 = 50 Hz4. Impeller 110 = 110 mm 120 = 120 mm 130 = 130 mm 140 = 140 mm 145 = 145 mm 150 = 150 mm 155 = 155 mm 160 = 160 mm5. Motor power 007 = 0.75 kW (IEC 80) 011 = 1.1 kW (IEC 90S) 015 = 1.5 kW (IEC 90L) 022 = 2.2 kW (IEC 100L) 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 132S)

TP02030450110

007

Designation Code of selection characteristicsPosExample

PositionND654

02 0 3 0 4253

0PT1

Code 085 0N

7F K 0 4 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 19 m³/h

Pump head max. 9 m w.c.

Housing pressure max. 16 bar

TP 2030

Motor size b c** d f h m n p t* u v w x y*

80 488 394 121.5 285 352 85 228 125 25.5 92 135 82 40 25.590S / 90L 494 429 121.5 285 352 85 228 140 25.5 90 135 82 40 25.5

100L (2.2 kW / 3 kW) 606 478/493 131.5 335 403 85 278 160 25.5 112 135 85 40 25.5112M 606 500 131.5 335 403 85 278 190 25.5 112 135 85 40 25.5132S 707 557 152 410 444 85 332 216 25.5 132 135 85 40 25.5

Page 43: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

Impeller diameter

Required motor power

Required NPSH-value

43

GEA Tuchenhagen

Standard TP

Standard TPS

Performance curves, centrifugal pump, type TP 2030, 4-pole (n=1,450 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

50 Hz

4-pole

50 Hz50 Hz0

H

11

10

9

8

7

6

5

4

3

2

1

[m][ft]

NPSH[m]

P[kW]

0

USGPM0

0

[ft]

1

1.0

2.5

3.5

0

Q [m3/h]

10 20 30 40 50 60 70

0 10

35

30

25

20

15

10

5

0

4.0

2.0

0

1.0

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

20 30 40 50 60

3.0

0.5

80

70

18

18

19

19

19

20

20

20

0.4

0.3

0.2

0.1

17 18

0.6

0.5

2.0

3.0

[hp]

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

Q [m3/h]

Q [m3/h]

Ø160

Ø150

Ø140

Ø130Ø120

IGPM

Ø110

η 0.60

Ø160

Ø150

Ø140

Ø130

Ø120

Ø110

Ø110

η 0.45 η 0.55η 0.50η 0.35η 0.30 η 0.40

Ø160

Page 44: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

44

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 2050, 4-pole (n=1,450 min-1), 50 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 20502. Speed 4 = 4 pole3. Frequency 50 = 50 Hz4. Impeller 160 = 160 mm 170 = 170 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm5. Motor power 007 = 0.75 kW (IEC 80) 011 = 1.1 kW (IEC 90S) 015 = 1.5 kW (IEC 90L) 022 = 2.2 kW (IEC 100L) 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M)

TP02050450160

007

Designation Code of selection characteristicsPosExample

PositionND654

02 0 5 0 4253

0PT1

Code 086 5N

7F K 0 5 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 19 m³/h

Pump head max. 15 m w.c.

Housing pressure max. 16 bar

TP 2050

Motor size b c** d f h m n p t* u v w x y*

80 504 410 126 285 352 107 228 125 25.5 90 161 82 52 25.590S / 90L 510 445 126 285 352 107 228 140 25.5 90 161 82 52 25.5

100L (2.2 kW / 3 kW) 622 494/509 136 335 403 107 278 160 25.5 112 161 85 52 25.5112M 622 516 136 335 403 107 278 190 25.5 112 161 85 52 25.5

Page 45: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

0 5 10 12.5 15 17.5 202.5 7.5

0 5 10 12.5 15 17.5 202.5 7.5

0 5 10 12.5 15 17.5 202.5 7.5

50 Hz50 Hz

20

18

16

14

12

10

8

6

4

2

NPSH[m]

[kW]

0

0.5

1.0

1.5

0

[ft]

0

Q [m3/h]

60

50

40

30

20

10

0

Q [m3/h]

Q [m3/h]

2.0

12.5

0

[hp]P

5

0

1.0

0.5

1.5

2.0

2.5

H[m][ft] USGPM0 10 20 30 40 50 60 70

0 10 20 30 40 50 60

80

70 IGPM

0.5

1.5

η 0.52

η 0.50

η 0.45η 0.40

η 0.45η 0.40

Ø210

Ø160Ø210

Ø210

Ø200Ø190

Ø180

Ø160

η 0.50

η 0.52Ø200

Ø190

Ø180Ø170Ø160

η 0.45

η 0.45

Ø170

45

GEA TuchenhagenRequired motor power

Required NPSH-value

Standard TP

Standard TPS

Performance curves, centrifugal pump, type TP 2050, 4-pole (n=1,450 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

Impeller diameter

50 Hz

4-pole

Page 46: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

46

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 2575, 4-pole (n=1,450 min-1), 50 Hz

TP 2575 Motor size b c** d f h m n p t* u v w x y*

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

100L / 112M 621 508/515 138 335 403 124.5 278 160/190 25.5 112 190 85 48.5 25.5

132S / 132M 720 570/630 156 410 444 124.5 332 216 25.5 132 190 85 48.5 25.5

1. Type TP 25752. Speed 4 = 4 pole3. Frequency 50 = 50 Hz4. Impeller 200 = 200 mm 210 = 210 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm 230 = 230 mm 235 = 235 mm 240 = 240 mm 245 = 245 mm 250 = 250 mm5. Motor power 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 132S) 075 = 7.5 kW (IEC 132M)

TP02575450200

030

Designation Code of selection characteristicsPosExample

PositionND654

02 5 7 5 4253

0PT1

Code 086 5N

7F K 0 5 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 20 m³/h

Pump head max. 21 m w.c.

Housing pressure max. 16 bar

Page 47: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

47

GEA TuchenhagenImpeller diameter

Required motor power

Required NPSH-value

Standard TP

Standard TPS

Performance curves, centrifugal pump, type TP 2575, 4-pole (n=1,450 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

50 Hz50 Hz0

22

18

8

6

4

2

NPSH[m]

P

[kW]

0

0

[ft]

10

Q [m3/h]

70

60

50

40

30

20

02 3 4 5 6 7 8 9 10 11 12 13 14 15 16

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

18

18

19

19

19

20

20

20

17 18

1

0.5

[hp]

H

[m][ft] USGPM0 10 20 30 40 50 60 70

0 10 20 30 40 50 60

80

70

Q [m3/h]

Q [m3/h]

0

0

IGPM

90

80

21 22

10

12

14

16

20

10

0.20.40.60.81.01.21.41.61.82.02.1

0.4

0.8

1.2

1.6

2.0

2.4

2.8

21 22

1.5

21 22

1

2

3

4 Ø 2 0 0 Ø 2 5 0

Ø 2 5 0

Ø 2 4 0

Ø 2 3 0

Ø 2 2 0Ø 2 1 0

Ø 2 0 0

Ø 2 0 0

Ø 2 1 0

Ø 2 2 0

Ø 2 3 0

Ø 2 4 0

Ø 2 5 0 η 0.35

η 0.44

η 0.48

η 0.46η 0.46

η 0.40

η 0.44

η 0.35

η 0.40

η 0.44

50 Hz

4-pole

Page 48: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

48

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 3050, 4-pole (n=1,450 min-1), 50 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 30502. Speed 4 = 4 pole3. Frequency 50 = 50 Hz4. Impeller 140 = 140 mm 150 = 150 mm 160 = 160 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm5. Motor power 007 = 0.75 kW (IEC 80) 011 = 1.1 kW (IEC 90S) 015 = 1.5 kW (IEC 90L) 022 = 2.2 kW (IEC 100L) 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 132S) 075 = 7.5 kW (IEC 132M)

TP03050450140

007

Designation Code of selection characteristicsPosExample

PositionND654

03 0 5 0 4253

0PT1

Code 086 5N

7F K 0 5 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 36 m³/h

Pump head max. 16 m w.c.

Housing pressure max. 16 bar

TP 3050

Motor size b c** d f h m n p t* u v w x y*

80 500 406 124 285 352 103 228 125 25.5 92 155 82 50 25.590S / 90L 506 441 124 285 352 103 228 140 25.5 90 155 82 50 25.5

100L (2.2 kW / 3 kW) 618 490/505 134 335 403 103 278 160 25.5 112 155 85 50 25.5112M 618 512 134 335 403 103 278 190 25.5 112 155 85 50 25.5

132S / 132M 719 569/609 154 410 444 103 332 216 25.5 132 155 85 50 25.5

Page 49: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

49

GEA TuchenhagenImpeller diameter

Required motor power

Required NPSH-value

Standard TP

Standard TPS

Performance curves, centrifugal pump, type TP 3050, 4-pole (n=1,450 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

50 Hz50 Hz

20

18

16

14

12

10

8

6

4

2

NPSH[m]

[kW]

0

0.5

1.0

1.5

0

[ft]

0

1

0

0 5 10 15 20 25 30 35Q [m3/h]

60

50

40

30

20

10

0

40

5 10 15 20 25 30 35Q [m3/h]

40

0 5 10 15 20 25 30 35Q [m3/h]

40

2.0

2

5.0

0

2.5

7.5

[hp]P

10

0

3

1.0

0.5

1.5

2.0

2.5

H

[m][ft] USGPM0 20 40 60 80 100 120 140

0 20 40 60 80 100 120

160

140 IGPM

η 0.61

η 0.50

η 0.45η 0.40

η 0.45

η 0.40

Ø210

Ø140Ø210

η 0.55

Ø210

Ø200

Ø190

Ø180

Ø170Ø160

Ø150Ø140

η 0.60

η 0.60

η 0.55

η 0.55

Ø200

Ø190

Ø180

Ø170

Ø160

Ø150

Ø140

50 Hz

4-pole

Page 50: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

50

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 5060, 4-pole (n=1,450 min-1), 50 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 50602. Speed 4 = 4 pole3. Frequency 50 = 50 Hz4. Impeller 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm5. Motor power 022 = 2.2 kW (IEC 100L) 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 132S) 075 = 7.5 kW (IEC 132M)

TP05060450155

022

Designation Code of selection characteristicsPosExample

PositionND654

05 0 6 0 4253

0PT1

Code 088 0N

7F K 0 6 5

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 40 m³/h

Pump head max. 17 m w.c.

Housing pressure max. 16 bar

TP 5060

Motor size b c** d f h m n p t* u v w x y*

100L (2.2 kW / 3 kW) 622 494/509 137 335 403 114.5 278 160 27.5 112 230 85 51 25.5112M 622 516 137 335 403 114.5 278 190 27.5 112 230 85 51 25.5

132S / 132M 723 573/613 157 410 444 114.5 332 216 27.5 132 230 85 51 25.5

Page 51: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

51

GEA TuchenhagenImpeller diameter

Required motor power

Required NPSH-value

Standard TP

Standard TPS

Performance curves, centrifugal pump, type TP 5060, 4-pole (n=1,450 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

50 Hz50 HzNPSH

[m]

P[hp]

0

0

[ft]

0 5 10 15 20 25 30 35 400

0.5

1.0

1.5

2.0

45

60

30

15

0

1.00

Q [m3/h]

Q [m3/h]

Q [m3/h]

H

[m][ft]USGPM

0

0

5

10

15

20

0 5 10 15 20 25 30 35 40

0 5 10 15 20 25 30 35 40

0.5

1.0

1.5

2.0

2.5

3.0

20 40 60 80 100 120 140 160 180

20 40 60 80 100 120 140

0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

[kW]

2.03.04.05.06.07.0

IGPMη 0.50

η 0.55

η 0.62

Ø175Ø185

Ø195

Ø205

Ø215

Ø225

Ø 1 9 5

Ø 1 8 5

Ø 2 0 5

Ø 2 1 5

Ø 2 2 5

Ø 1 6 5

Ø 1 7 5

Ø 1 5 5

Ø 1 5 5

Ø 2 2 5

η 0.58η 0.45η 0.40

η 0.50

η 0.55

η 0.45

η 0.40

η 0.58

Ø165Ø155

50 Hz

4-pole

Page 52: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

52

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 7060, 4-pole (n=1,450 min-1), 50 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 70602. Speed 4 = 4 pole3. Frequency 50 = 50 Hz4. Impeller 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm5. Motor power 022 = 2.2 kW (IEC 100L) 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 132S) 075 = 7.5 kW (IEC 132M)

TP07060450155

022

Designation Code of selection characteristicsPosExample

PositionND654

07 0 6 0 4253

0PT1

Code 088 0N

7F K 0 6 5

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 55 m³/h

Pump head max. 19 m w.c.

Housing pressure max. 16 bar

TP 7060

Motor size b c** d f h m n p t* u v w x y*

100L (2.2 kW / 3 kW) 622 494/509 132 335 427 110 278 160 27.5 112 230 85 56 25.5112M 622 516 132 335 427 110 278 190 27.5 112 230 85 56 25.5

132S / 132M 723 573/613 152 410 444 110 332 216 27.5 132 230 85 56 25.5

Page 53: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

53

GEA TuchenhagenRequired motor power

Required NPSH-value

Standard TP

Standard TPS

Performance curves, centrifugal pump, type TP 7060, 4-pole (n=1,450 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

50 Hz50 Hz

H[m][ft]

NPSH[m]

USGPM

0

0.5

1.0

1.5

2.0

[ft]

0 5 10 15 20 25 30 35 40 45 50 55 60 650

0

60

50

30

20

10

0

6.0

4.0

2.0

0

Q [m3/h]

5

10

15

20

40

25 50 75 100 125 150 175 200 225 250 275

25 50 75 100 125 150 175 200 225

0 5 10 15 20 25 30 35 40 45 50 55 60 65P

[kW]

0

Q [m3/h]

Q [m3/h]0 5 10 15 20 25 30 35 40 45 50 55 60 65

0.5

1.0

1.5

2.0

2.5

0

[hp]

0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

3.0

3.5

4.0

4.5

5.0

3.0

2.58.0

10.0

IGPMØ225

Ø215

Ø205Ø195Ø185Ø175Ø165

Ø155Ø225

Ø215

Ø205

Ø195

Ø185Ø175

Ø165Ø155

η 0.66

η 0.65

η 0.50 η 0.60η 0.55

Ø155

Ø225

η 0.60

η 0.55

η 0.50

Impeller diameter

50 Hz

4-pole

Page 54: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

54

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 8080, 4-pole (n=1,450 min-1), 50 Hz

TP 8080 Motor size b c** d f h m n p t* u v w x y*

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

112M 641 535 136 335 403 124 278 190 27.5 112 250 85 71 25.5

132S / 132M 742 592/632 156 410 444 124 332 216 27.5 132 250 85 71 25.5

1. Type TP 80802. Speed 4 = 4 pole3. Frequency 50 = 50 Hz4. Impeller 180 = 180 mm 190 = 190 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm 230 = 230 mm 235 = 235 mm 240 = 240 mm 245 = 245 mm 250 = 250 mm5. Motor power 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 132S) 075 = 7.5 kW (IEC 132M)

TP08080450180

040

Designation Code of selection characteristicsPosExample

PositionND654

08 0 8 0 4253

0PT1

Code 180 0N

7F K 0 6 5

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 100; Pressure port (DS), DN 65

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 65 m³/h

Pump head max. 23 m w.c.

Housing pressure max. 16 bar

Page 55: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

55

GEA TuchenhagenImpeller diameter

Required motor power

Required NPSH-value

Standard TP

Standard TPS

Performance curves, centrifugal pump, type TP 8080, 4-pole (n=1,450 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

50 Hz50 Hz

H

[m][ft]

NPSH[m]

USGPM

0

0.5

1.0

1.5

2.0

[ft]

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 750

0

70

60

50

30

20

10

0

6.0

4.0

2.0

0

Q [m3/h]

5

10

15

20

25

40

80

25 50 75 100 125 150 175 200 225 250 275 300 325

25 50 75 100 125 150 175 200 225 250

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75P

[kW]

0

Q [m3/h]

Q [m3/h]0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75

1.0

2.0

3.0

4.0

5.0

0

[hp]

0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

IGPM

Ø250

Ø240

Ø230

Ø220

Ø210

Ø200

Ø190

Ø180

Ø250

Ø250Ø240

Ø230

Ø220

Ø210Ø200

Ø180Ø190

η 0.66

η 0.64

η 0.50

η 0.50

η 0.60

η 0.60η 0.55

η 0.55

η 0.45η 0.40

Ø180

50 Hz

4-pole

Page 56: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

56

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 16040, 4-pole (n=1,450 min-1), 50 Hz

TP 16040 Motor size b c** d f h m n p t* u v w x y*

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

100L / 112M 651 538/545 131 335 403 108 278 160/190 29.5 112 280 85 86 27.5

132S / 132M 752 602/642 151 410 444 108 332 216 29.5 132 280 85 86 27.5

1. Type TP 160402. Speed 4 = 4 pole3. Frequency 50 = 50 Hz4. Impeller 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 5. Motor power 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 132S) 075 = 7.5 kW (IEC 132M)

TP16040450160

030

Designation Code of selection characteristicsPosExample

PositionND654

06 0 4 0 2453

1PT1

Code 185 0N

7F K 1 0 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 150; Pressure port (DS), DN 100

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 100 m³/h

Pump head max. 12 m w.c.

Housing pressure max. 16 bar

Page 57: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

57

GEA TuchenhagenRequired NPSH-value

Standard TP

Standard TPS

Performance curves, centrifugal pump, type TP 16040, 4-pole (n=1,450 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

50 Hz50 Hz0

11

2

NPSH[m]

0

[ft]

1.0

2.0

3.0

0

Q [m3/h]

35

30

25

20

15

10

0

8.0

4.0

0

2.0

0

6.0

0.5

1.5

2.5

Q [m3/h]

10

12

5

40

P[kW][hp]

00

2.0

1.5

1.0

0.5

2.5

0

0.5

Q [m3/h]

3.0

3.5

H

[m][ft]USGPM

1

3

4

5

6

7

8

9

4.5

5 10 15 20 25 30 35 40 45 10050 60 70 80 90 1059585756555

5 10 15 20 25 30 35 40 45 10050 60 70 80 90 1059585756555

0.5

1.0

1.5

2.0

2.5

3.0

4.0

4.5

5.0

5.5

5 10 15 20 25 30 35 40 45 10050 60 70 80 90 1059585756555

3.5

4.0

10

12

0

0 50 IGPM

100 150 200 250 300 350

45050 400350300250200150100

Ø160

Ø190

Ø200

Ø170

Ø180

Ø190

Ø200

Ø200

Ø160

Ø160

Ø180

Ø170

η 0.50

η 0.55

η 0.60

η 0.65

η 0.67η 0.65

η 0.60η 0.55η 0.50

η 0.45η 0.40

Impeller diameter

Required motor power

50 Hz

4-pole

Page 58: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

Standard version 2 pole/60Hz

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Depending on pump size

Mechanical seal Single-acting, material: C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Standard equipment Stainless steel protection hood and base frame with height-adjustable

calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F, incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 240 m3/h

Pump head max. 130 m w.c.

58

GEA Tuchenhagen

Standard version, centrifugal pump, type TP, 2-pole (n=3,500 min-1), 60 Hz

8005004003002001005030 40USGPM

1 2 0 0

20 30 40 50 100 200 300 400 500 700IGPM

1 0 0 0

50

40

30

20

10

5

1

H[m]

100

150

1 10 20 30 40 50 70

Q [m3/h]

100 200 300

n = 3,500 min-1

TP 3050-2

TP 1540-2

TP 2030-2

TP 8080-2

TP 16040-2

TP2050-2

TP 1020-2

TP 2575-2TP 5060-2 TP 7060-2

Performance characteristics TP

TP 1020 TP 1540 bis TP8080 TP 16040

Page 59: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

59

GEA Tuchenhagen

Standard TP

60 Hz

2-pole

Standard TPS

1. Type TP010202. Speed 2 = 2 pole3. Frequency 60 = 60 Hz4. Impeller 080 = 80 mm 100 = 100 mm 120 = 120 mm 090 = 90 mm 110 = 110 mm 130 = 130 mm5. Motor power 012 = 1.25 kW (IEC 80) 015 = 1.5 kW (IEC 90S) 022 = 2.2 kW (IEC 90L) 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 112M)

Example of a standard selection

60 Hz60 HzNPSH

[m]

P[kW]

0

[ft]

2 4 6 8 10 12 14 16 18 20 22 2400

4

8

0

1

2

3

4

0

100

80

60

20

10

0

Q [m3/h]2 4 6 8 10 12 14 16 18 20 22 24

2 4 6 8 10 12 14 16 18 20 22 240.4

0.8

1.2

1.6

2.0

2.4

26

26

26

5

40

2.8

12.5

2.5

7.5

η 0.30

0.8

1.2

1.6

2.0

2.8

2.4

3.6

3.2

[hp]

0

0.4

Q [m3/h]

Q [m3/h]

H

[ft]0 20 40 60 80

0 20 40 60 80

100[m]

U S G P M

12

16

20

24

28

32

36120η 0.25

η 0.45

Ø 1 3 0

Ø 1 2 0

Ø 1 1 0

Ø 9 0

Ø 1 0 0

Ø 8 0

η 0.50

η 0.35 η 0.40

Ø 1 0 0

Ø 1 1 0

Ø 1 2 0

Ø 9 0

IGPM

Ø 1 3 0

Ø 1 3 0

Ø 8 0

Ø 8 0

Performance curves, centrifugal pump,TP 1020 (2-polig / 60 Hz)

Selected valuesdetermined by thepump selected

Selection using thecharacteristic curves

TP01020260080

012

Designation Code of selection characteristicsPosExample

Impeller diameter

Required motor power

Erforderlich NPSH

Motor output selection inaccordance with capacity

and pump head

Impeller selection inaccordance with capacity

and pump head

Standard version, for other versions see options

PositionND654

01 0 2 0 2263

0PT1

Code 085 0N

7F K 0 4 0

9 10E K E - 1

111213-14

J15

J16

-17

Page 60: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

60

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 1020, 2-pole (n=3,500 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 10202. Speed 2 = 2 pole3. Frequency 60 = 60 Hz4. Impeller 080 = 80 mm 100 = 100 mm 120 = 120 mm 090 = 90 mm 110 = 110 mm 130 = 130 mm5. Motor power 012 = 1.25 kW (IEC 80) 015 = 1.5 kW (IEC 90S) 022 = 2.2 kW (IEC 90L) 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 112M)

TP01020260080

012

Designation Code of selection characteristicsPosExample

PositionND654

01 0 2 0 2263

0PT1

Code 085 0N

7F K 0 4 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 24 m³/h

Pump head max. 34 m w.c.

Housing pressure max. 10 bar

TP 1020Motor size b c** d f h m n p t* u v w x y*

80 484 390 144 285 352 76 228 125 25.5 92 125 82 14 25.590S / 90L 490 425 144 285 352 76 228 140 25.5 90 125 82 14 25.5

100L / 112M 602 474/496 154 335 403 76 278 160 25.5 112 125 85 14 25.5

Page 61: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

61

GEA Tuchenhagen

Standard TP

Standard TPS

Performance curves, centrifugal pump, type TP 1020, 2-pole (n=3,500 min-1), 60 HzImpeller diameter

Required motor power

Required NPSH-value

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 HzNPSH

[m]

P[kW]

0

[ft]

2 4 6 8 10 12 14 16 18 20 22 2400

4

8

0

1

2

3

4

0

100

80

60

20

10

0

Q [m3/h]2 4 6 8 10 12 14 16 18 20 22 24

2 4 6 8 10 12 14 16 18 20 22 240.4

0.8

1.2

1.6

2.0

2.4

26

26

26

5

40

2.8

12.5

2.5

7.5

η 0.30

0.8

1.2

1.6

2.0

2.8

2.4

3.6

3.2

[hp]

0

0.4

Q [m3/h]

Q [m3/h]

H

[ft]0 20 40 60 80

0 20 40 60 80

100[m] U S G P M

12

16

20

24

28

32

36120

η 0.45

Ø 1 3 0

Ø 1 2 0

Ø 1 1 0

Ø 9 0

Ø 1 0 0

Ø 8 0

η 0.50

η 0.35 η 0.40

Ø 1 0 0

Ø 1 1 0

Ø 1 2 0

Ø 9 0

IGPM

Ø 1 3 0

Ø 1 3 0

Ø 8 0

Ø 8 0

η 0.25

60 Hz

2-pole

Page 62: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

62

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 1540, 2-pole (n=3,500 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 15402. Speed 2 = 2 pole3. Frequency 60 = 60 Hz4. Impeller 130 = 130 mm 140 = 140 mm 145 = 145 mm 150 = 150 mm 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm5. Motor power 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 112M) 075 = 7.5 kW (IEC 112M) 110 = 11.0 kW (IEC 132M) 150 = 15.0 kW (IEC 132M)

TP01540260130

030

Designation Code of selection characteristicsPosExample

PositionND654

01 5 4 0 2263

0PT1

Code 086 5N

7F K 0 4 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 40

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 44 m³/h

Pump head max. 62 m w.c.

Housing pressure max. 16 bar

TP 1540Motor size b c** d f h m n p t* u v w x y*100L 608 480 131.5 335 403 90 278 160 25.5 112 140 85 42 25.5

112M (4 kW + 5.5 kW) 608 502 131.5 335 403 90 278 190 25.5 112 140 85 42 25.5112M (7.5 kW) 608 524 131.5 335 403 90 278 190 25.5 112 140 85 42 25.5132M (11 kW) 709 619 152 410 444 90 332 216 25.5 132 140 85 42 25.5132M (15 kW) 709 670 152 410 444 90 332 216 25.5 132 140 85 42 25.5

Page 63: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

63

GEA Tuchenhagen

Standard TP

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 1540, 2-pole (n=3,500 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 Hz

H

[m][ft]

NPSH[m]

P[kW]

USGPM0

0

[ft]

4 8 12 16 20 24 28 32 36 40 44 4800

10

20

30

40

50

60

70

4 8 12 16 20 24 28 32 36 40 44 480

1

2

3

4

25 50 75 100 125 150 175 200

0 25 50 75 100 125 150 175

200

150

100

50

10

5

0

225

52

52

[hp]

Q [m3/h]

Q [m3/h]

0

1

2

4

6

8

10

4 8 12 16 20 24 28 32 36 40 44 480 52

12

Q [m3/h]

2

4

6

8

10

12

14

1

IGPMη 0.45

η 0.50 η 0.55η 0.40

η 0.57

η 0.35Ø 1 8 0

Ø 1 7 0

Ø 1 6 0

Ø 1 5 0

Ø 1 4 0

Ø 1 3 0

η 0.30

Ø 1 8 0Ø 1 3 0

Ø 1 8 0

Ø 1 7 0

Ø 1 6 0

Ø 1 5 0

Ø 1 4 0

Ø 1 3 0

60 Hz

2-pole

Page 64: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

64

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 2030, 2-pole (n=3,500 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 20302. Speed 2 = 2 pole3. Frequency 60 = 60 Hz4. Impeller 110 = 110 mm 120 = 120 mm 130 = 130 mm 140 = 140 mm 145 = 145 mm 150 = 150 mm 155 = 155 mm 160 = 160 mm5. Motor power 015 = 1.5 kW (IEC 90S) 022 = 2.2 kW (IEC 90L) 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 112M) 075 = 7.5 kW (IEC 112M) 110 = 11.0 kW (IEC 132M)

TP02030260110

015

Designation Code of selection characteristicsPosExample

PositionND654

02 0 3 0 2263

0PT1

Code 085 0N

7F K 0 4 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 44 m³/h

Pump head max. 52 m w.c.

Housing pressure max. 16 bar

TP 2030Motor size b c** d f h m n p t* u v w x y*90S / 90L 494 429 121.5 285 352 85 228 140 25.5 90 135 82 40 25.5100L 606 478 131.5 335 403 85 278 160 25.5 112 135 85 40 25.5

112M (4 kW + 5.5 kW) 606 500 131.5 335 403 85 278 190 25.5 112 135 85 40 25.5112M (7.5 kW) 606 522 131.5 335 403 85 278 190 25.5 112 135 85 40 25.5

132M 707 617 152 410 444 85 332 216 25.5 132 135 85 40 25.5

Page 65: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

65

GEA Tuchenhagen

Standard TP

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 2030, 2-pole (n=3,500 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 Hz

H

[m][ft]

NPSH[m]

P[kW]

0

USGPM0

0

[ft]

4 8 12 16 20 24 28 32 36 40 44 4800

8

16

24

32

40

48

56

4 8 12 16 20 24 28 32 36 40 44 480

2

4

6

8

10

1

2

3

4

4 8 12 16 20 24 28 32 36 40 44 480

25 50 75 100 125 150 175 200

0 25 50 75 100 125 150 175

100

25

10

5

0

Q [m3/h]

225

52

52

52

[hp]

0

2

4

8

50

75

125

150

175175

6

10

12

Q [m3/h]

Q [m3/h]

0

IGPMη 0.40 η 0.45

Ø 1 6 0

Ø 1 5 0

Ø 1 1 0 Ø 1 2 0

Ø 1 3 0

Ø 1 1 0 Ø 1 6 0

Ø 1 1 0

Ø 1 6 0

Ø 1 4 0

Ø 1 5 0

Ø 1 2 0

Ø 1 3 0

Ø 1 4 0

η 0.35η 0.30

η 0.60

η 0.50

60 Hz

2-pole

Page 66: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

66

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 2050, 2-pole (n=3,500 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 20502. Speed 2 = 2 pole3. Frequency 60 = 60 Hz4. Impeller 160 = 160 mm 170 = 170 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm5. Motor power 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 112M) 075 = 7.5 kW (IEC 112M) 110 = 11.0 kW (IEC 132M) 150 = 15.0 kW (IEC 132M)

TP02050260160

030

Designation Code of selection characteristicsPosExample

PositionND654

02 0 5 0 2263

0PT1

Code 086 5N

7F K 0 5 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 42 m³/h

Pump head max. 85 m w.c.

Housing pressure max. 16 bar

TP 2050Motor size b c** d f h m n p t* u v w x y*100L 622 494 136 335 403 107 278 160 25.5 112 161 85 52 25.5

112M (4 kW + 5.5 kW) 622 516 136 335 403 107 278 190 25.5 112 161 85 52 25.5112M (7.5 kW) 622 538 136 335 403 107 278 190 25.5 112 161 85 52 25.5132M (11 kW) 723 633 156 410 444 107 332 216 25.5 132 161 85 52 25.5132M (15 kW) 723 684 156 410 444 107 332 216 25.5 132 161 85 52 25.5

Page 67: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

67

GEA Tuchenhagen

Standard TP

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 2050, 2-pole (n=3,500 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 HzNPSH

[m]

P[kW]

0

0

[ft]

00

10

20

30

40

50

60

70

80

90

0

0 5 10 15 20 25 30 35 40

300

250

200

150

100

50

0

10

5

0

Q [m3/h]

Q [m3/h]

Q [m3/h]

H[m][ft] USGPM

0 25 50 75 100 125 150 175

1501251007550250

100

110350

7.5

10

15

20

[hp]

10

15

5

IGPM

200

45

5

0

1

2

3

2.5

Ø 2 1 0η 0.50

η 0.45

η 0.52Ø 2 0 0

Ø 1 9 0

Ø 1 8 0

Ø 1 7 0Ø 1 6 0

Ø 1 6 0 Ø 2 1 0

η 0.45η 0.40

η 0.52η 0.50

η 0.40

5 10 15 20 25 30 35 40 45

5 10 15 20 25 30 35 40 45

Ø210

Ø200

Ø190

Ø180Ø170

Ø160

η 0.45

60 Hz

2-pole

Page 68: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

68

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 2575, 2-pole (n=3,500 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 25752. Speed 2 = 2 pole3. Frequency 60 = 60 Hz4. Impeller 200 = 200 mm 210 = 210 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm 230 = 230 mm 235 = 235 mm 240 = 240 mm 245 = 245 mm 250 = 250 mm5. Motor power 055 = 5.5 kW (IEC 112M) 075 = 7.5 kW (IEC 112M) 110 = 11.0 kW (IEC 132M) 150 = 15.0 kW (IEC 132M) 212 = 21.2 kW (IEC 160L) 220 = 22.0 kW (IEC 160L) 300 = 30.0 kW (IEC 200L)

TP0257526020

055

Designation Code of selection characteristicsPosExample

PositionND654

02 5 7 5 2263

0PT1

Code 086 5N

7F K 0 5 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 48 m³/h

Pump head max. 130 m w.c.

Housing pressure max. 16 bar

TP 2575

Motor size b c** d f h m n p t* u v w x y*

112M (5.5 kW / 7.5 kW) 621 515/537 138 335 403 124.5 278 190 25.5 112 190 85 48.5 25.5132M (11 kW) 720 630 156 410 444 107 332 216 25.5 132 190 85 48.5 25.5132M (15 kW) 720 681 156 410 444 107 332 216 25.5 132 190 85 48.5 25.5

160L 894 782 191 640 598 124.5 412 254 25.5 160 190 110 48.5 25.5200L 1,033 908 200.5 810 668 124.5 472 318 25.5 200 190 115 48.5 25.5

Page 69: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

69

GEA Tuchenhagen

Standard TP

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 2575, 2-pole (n=3,500 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 Hz

H

[m][ft]

NPSH[m]

P[kW]

0

USGPM0

0

[ft]

4 8 12 16 20 24 28 32 36 40 44 4800

40

60

80

4 8 12 16 20 24 28 32 36 40 44 480

5

1.0

4 8 12 16 20 24 28 32 36 40 44 480

25 50 75 100 125 150 175 200

0 25 50 75 100 125 150 175

5

0

Q [m3/h]

225

52

52

52

[hp]

0

Q [m3/h]

Q [m3/h]

0

5

15

2.0

3.0

4.0

56

10

20

30

50

70

90

130

100

110

120

140

56

10

15

20

25

30

100

50

150

200

250

300

350

400

450

10

15

20

25

30

35

40

10

56

IGPM

Ø 2 5 0

Ø 2 5 0

Ø 2 4 0

Ø 2 3 0

Ø 2 2 0

Ø 2 1 0

Ø 2 0 0

Ø 2 0 0

Ø 2 5 0

Ø 2 4 0

Ø 2 3 0

Ø 2 2 0

Ø 2 1 0

Ø 2 0 0

η 0.35

η 0.44

η 0.46η 0.46

η 0.40

η 0.44

η 0.44

η 0.48

η 0.35η 0.40

60 Hz

2-pole

Page 70: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

70

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 3050, 2-pole (n=3,500 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 30502. Speed 2 = 2 pole3. Frequency 60 = 60 Hz4. Impeller 140 = 140 mm 150 = 150 mm 160 = 160 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm5. Motor power 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 112M) 075 = 7.5 kW (IEC 112M) 110 = 11.0 kW (IEC 132M) 150 = 15.0 kW (IEC 132M) 212 = 21.2 kW (IEC 160L) 220 = 22.0 kW (IEC 160L)

TP03050260140

030

Designation Code of selection characteristicsPosExample

PositionND654

03 0 5 0 2263

0PT1

Code 086 5N

7F K 0 5 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 85 m³/h

Pump head max. 95 m w.c.

Housing pressure max. 16 bar

TP 3050

Motor size b c** d f h m n p t* u v w x y*

100L 618 504 134 335 403 103 278 160 25.5 112 155 85 50 25.5112M (4 kW + 5.5 kW) 618 515 134 335 403 103 278 190 25.5 112 155 85 50 25.5112M (7.5 kW) 618 534 134 335 403 103 278 190 25.5 112 155 85 50 25.5132M (11 kW) 719 629 154 410 444 103 332 216 25.5 132 155 85 50 25.5132M (15 kW) 719 680 154 410 444 103 332 216 25.5 132 155 85 50 25.5

160L 893 781 189 640 598 103 412 254 25.5 160 155 110 50 25.5

Page 71: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

71

GEA Tuchenhagen

Standard TP

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 3050, 2-pole (n=3,500 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 HzNPSH

[m]

P[kW]

0

0

[ft]

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 850

10

20

30

40

50

60

70

80

90

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85

1

3

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85

300

250

200

150

100

50

0

20

10

5

0

Q [m3/h]

Q [m3/h]

Q [m3/h]

H

[m][ft]USGPM

0 50 100 150 200 250 300 350

300250200150100500

100

110350

15

10

15

20

25

30

35

[hp]

10

15

20

25

30

5

IGPM

400

90

90

90

5

0

2

456

Ø 2 1 0

Ø210

η 0.60

η 0.50

η 0.45

η 0.55

η 0.60

Ø 2 0 0

Ø 1 9 0

Ø 1 8 0

Ø 1 7 0

Ø 1 6 0

Ø 1 5 0

Ø 1 4 0

Ø 1 4 0 Ø 2 1 0

Ø200

Ø190

Ø180

Ø170Ø160

Ø150

Ø140

η 0.61

η 0.45η 0.40

η 0.55η 0.50

η 0.40

60 Hz

2-pole

Page 72: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

72

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 5060, 2-pole (n=3,500 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 50602. Speed 2 = 2 pole3. Frequency 60 = 60 Hz4. Impeller 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm5. Motor power 055 = 5.5 kW (IEC 112M) 075 = 7.5 kW (IEC 112M) 110 = 11.0 kW (IEC 132M) 150 = 15.0 kW (IEC 132M) 212 = 21.2 kW (IEC 160L) 220 = 22.0 kW (IEC 160L) 300 = 30.0 kW (IEC 200L)

TP05060260155

055

Designation Code of selection characteristicsPosExample

PositionND654

05 0 6 0 2263

0PT1

Code 088 0N

7F K 0 6 5

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 80 m³/h

Pump head max. 110 m w.c.

Housing pressure max. 16 bar

TP 5060

Motor size b c** d f h m n p t* u v w x y*

112M (5.5 kW / 7.5 kW) 622 517/538 137 335 403 114.5 278 190 27.5 112 230 85 51 25.5132M (11 kW) 723 633 157 410 444 114.5 332 216 27.5 132 230 85 51 25.5132M (15 kW) 723 684 157 410 444 114.5 332 216 27.5 132 230 85 51 25.5

160L 897 785 192 640 598 114.5 412 254 27.5 160 230 110 52 25.5200L 1,030 905 195 810 673 114.5 472 318 27.5 200 230 115 52 25.5

Page 73: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

73

GEA Tuchenhagen

Standard TP

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 5060, 2-pole (n=3,500 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 HzNPSH

[m]

P[kW]

0

[ft]

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 850

10

20

30

40

50

60

70

80

90

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85

300

250

200

150

100

50

0

20

10

5

0

Q [m3/h]

Q [m3/h]

USGPM

300250200150100500

100

110350

15

[hp]

1234

56

H

[m][ft]0 50 100 150 200 250 300 350

IGPM120

400

350

90 95 100

90 95 100

50 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85

Q [m3/h]

10

15

20

25

30

35

10

15

20

25

30

5

35

40

40

45

50

90 95 100

Ø 2 2 5

Ø 2 1 5

Ø 2 0 5

Ø 1 9 5

Ø 1 8 5

Ø 1 7 5

η 0.58η 0.62

η 0.58

Ø225

Ø215

Ø205

Ø185

Ø155

Ø 1 6 5

Ø 1 5 5

Ø 1 5 5Ø 2 2 5

η 0.55

η 0.55

η 0.50

η 0.50

η 0.45

η 0.45

η 0.40

η 0.40

Ø195

Ø175

Ø165

60 Hz

2-pole

Page 74: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

74

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 7060, 2-pole (n=3,500 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 70602. Speed 2 = 2 pole3. Frequency 60 = 60 Hz4. Impeller 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm5. Motor power 075 = 7.5 kW (IEC 112M) 110 = 11.0 kW (IEC 132M) 150 = 15.0 kW (IEC 132M) 212 = 21.2 kW (IEC 160L) 220 = 22.0 kW (IEC 160L) 300 = 30.0 kW (IEC 200L)

TP07060260155

110

Designation Code of selection characteristicsPosExample

PositionND654

07 0 6 0 2263

0PT1

Code 088 0N

7F K 0 6 5

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 120 m³/h

Pump head max. 105 m w.c.

Housing pressure max. 16 bar

TP 7060

Motor size b c** d f h m n p t* u v w x y*

112M 622 538 132 335 427 110 278 190 27.5 112 230 85 56 25.5132M (11 kW) 723 633 152 410 444 110 332 216 27.5 132 230 85 56 25.5132M (15 kW) 723 684 152 410 444 110 332 216 27.5 132 230 85 56 25.5

160L 897 785 187 640 596 110 412 254 27.5 160 230 110 56 25.5200L 1,030 905 190.5 810 668 110 472 318 27.5 200 230 115 56 25.5

Page 75: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

75

GEA Tuchenhagen

Standard TP

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 7060, 2-pole (n=3,500 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 Hz

H

100

90

80

70

60

50

40

30

20

10

[m][ft]

NPSH[m]

P

0

USGPM100

01

23

45

[ft]

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 1500

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

10

20

30

40

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

200 300 400 5000 600

0 100 200 300 400 500

350

300

250

200

150

100

50

0

15

10

5

0

Q [m3/h]

Q [m3/h]

Q [m3/h]

[hp]

0

10

20

30

40

50

[kW]

50

60

60

70

IGPM

110

120

6202530

78

Ø 1 5 5 Ø 2 2 5

Ø 1 5 5

Ø175

Ø225

Ø215

Ø205Ø195

Ø185

Ø 1 6 5

Ø 2 2 5

Ø 1 7 5

Ø 1 8 5

Ø 1 9 5

Ø 2 0 5

Ø 2 1 5

Ø 1 6 5Ø 1 5 5

η 0.50

η 0.66

η 0.65

η 0.60η 0.55

η 0.55

η 0.60

η 0.50

60 Hz

2-pole

Page 76: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

76

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 8080, 2-pole (n=3,500 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 80802. Speed 2 = 2 pole3. Frequency 60 = 60 Hz4. Impeller 180 = 180 mm 190 = 190 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm 230 = 230 mm 235 = 235 mm 240 = 240 mm 245 = 245 mm 250 = 250 mm5. Motor power 110 = 11.0 kW (IEC 132M) 150 = 15.0 kW (IEC 132M) 212 = 21.2 kW (IEC 160L) 220 = 22.0 kW (IEC 160L) 300 = 30.0 kW (IEC 200L) 370 = 37.0 kW (IEC 200L) 450 = 45.0 kW (IEC 225M)

TP08080260180

150

Designation Code of selection characteristicsPosExample

PositionND654

08 0 8 0 2263

0PT1

Code 180 0N

7F K 0 6 5

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 100; Pressure port (DS), DN 65

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 125 m³/h

Pump head max. 130 m w.c.

Housing pressure max. 16 bar

TP 8080

Motor size b c** d f h m n p t* u v w x y*

132M 742 652/703 156 410 444 124 332 216 27.5 132 250 85 71 25.5160L 916 804 191 640 598 124 412 254 27.5 160 250 110 71 25.5200L 1,050 925 195 810 668 124 472 318 27.5 200 250 115 71 25.5225M 1,076 961 195 810 720 124 472 356 27.5 200 250 115 71 25.5

Page 77: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

77

GEA Tuchenhagen

Standard TP

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 8080, 2-pole (n=3,500 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 Hz

H

100

90

80

70

60

50

40

30

20

10

[m][ft]

NPSH[m]

P[kW]

USGPM100

0

2

4

6

8

10

[ft]

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 1500

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

10

20

30

40

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

200 300 400 5000 600

0 100 200 300 400 500

350

300

250

200

150

100

50

0

30

20

10

0

Q [m3/h]

Q [m3/h]

Q [m3/h]

110

120

130

400

50

10

20

30

40

60

50

70

[hp]

140450

160

160

160

IGPM

Ø210

η 0.66

Ø 2 3 0

Ø 2 2 0

Ø 2 1 0

Ø 2 0 0

Ø 2 5 0

Ø 2 5 0

Ø 2 4 0

Ø 1 9 0

Ø 1 8 0

Ø 1 8 0

η 0.64

η 0.60η 0.55

η 0.60

η 0.55

η 0.50η 0.45η 0.40

Ø250 Ø240 Ø230 Ø220

Ø180

Ø190

Ø200

η 0.50

60 Hz

2-pole

Page 78: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

78

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 16040, 2-pole (n=3,500 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 160402. Speed 2 = 2 pole3. Frequency 60 = 60 Hz4. Impeller 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 5. Motor power 110 = 11.0 kW (IEC 132M) 150 = 15.0 kW (IEC 132M) 212 = 21.2 kW (IEC 160L) 220 = 22.0 kW (IEC 160L) 300 = 30.0 kW (IEC 200L) 370 = 37.0 kW (IEC 200L) 450 = 45.0 kW (IEC 225M)

TP16040260180

150

Designation Code of selection characteristicsPosExample

PositionND654

06 0 4 0 2263

1PT1

Code 185 0N

7F K 1 0 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 150; Pressure port (DS), DN 100

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 240 m³/h

Pump head max. 70 m w.c.

Housing pressure max. 16 bar

TP 16040

Motor size b c** d f h m n p t* u v w x y*

132M 752 713 151 410 444 108 332 216 29.5 132 280 85 86 27.5160L 926 814 186 640 596 108 412 254 29.5 160 280 110 86 27.5200L 1,059 934 189 810 668 108 472 318 29.5 200 280 115 86 27.5225M 1,085 970 189 810 720 108 521 356 29.5 225 280 115 86 27.5

Page 79: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

79

GEA Tuchenhagen

Standard TP

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 16040, 2-pole (n=3,500 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 HzNPSH

[m]

P[kW]

0

[ft]

00

0

4

8

0

250

50

40

0

Q [m3/h]

12

16

0

10

20

30

40

50

20

60

50

10

30

10

20

30

40

60

50

80

70

[hp]

0

0

Q [m3/h]

Q [m3/h]

10

40

50

60

70

80

20

30

20 40 60 80 100 120 140 160 180 200 220 240 260

20 40 60 80 100 120 140 160 180 200 220 240 260

20 40 60 80 100 120 140 160 180 200 220 240 260

200

150

100

H

[ft]0

[m] U S G P M

1000900800700600500400100

900750600450300

200 300

12001050150

0

Ø 1 6 0

Ø 1 6 0

η 0.45

η 0.50

η 0.40

Ø 2 0 0

Ø 1 9 0

Ø 1 8 0

Ø 1 7 0

Ø 2 0 0

Ø 1 6 0

Ø 1 7 0

Ø 1 8 0

Ø 1 9 0

Ø 2 0 0 η 0.55 η 0.60η 0.65

η 0.67

η 0.65

η 0.60

η 0.55

η 0.50

IGPM

60 Hz

2-pole

Page 80: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

Standard version 4 pole/60Hz

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Depending on pump size

Mechanical seal Single-acting, material: C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Standard equipment Stainless steel protection hood and base frame with height-adjustable

calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F, incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 120 m3/h

Pump head max. 34 m w.c.

80

GEA Tuchenhagen

Standard version, centrifugal pump, type TP, 4-pole (n=1,750 min-1), 60 Hz

TP 2030-4

20

10

5

3

2

H[m]

2530

4020 30 40 50 100 200 300

USGPM4003002001005030 40

IGPM500

500 600

TP 5060-4

TP 1020-4

TP 1540-4

TP 2575-4

TP 3050-4

TP 8080-4

TP 16040-4

TP 2050-4

11 10 20 30 40 50

n = 1,750 min-1

Q [m3/h]100 140

TP 7060

Performance characteristics TP

TP 1020 TP 1540 bis TP8080 TP 16040

Page 81: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

81

GEA Tuchenhagen

Standard TP

60 Hz

4-pole

Standard TPS

Example of a standard selection

1. Type TP010202. Speed 4 = 4 pole3. Frequency 60 = 60 Hz4. Impeller 080 = 80 mm 100 = 100 mm 120 = 120 mm 090 = 90 mm 110 = 110 mm 130 = 130 mm5. Motor power 007 = 0.75 kW (IEC 80) 012 = 1.25 kW (IEC 90S) 018 = 1.8 kW (IEC 90L) 022 = 2.2 kW (IEC 100L)

60 Hz60 HzNPSH

[m]

P[kW]

0

[ft]

1 2 3 4 5 6 7 8 9 10 11 1200

1

2

0

0.5

1.0

1.5

2.0

25

20

15

5

0

Q [m3/h]1 2 3 4 5 6 7 8 9 10 11 12

13

13

10

η 0.30

[hp]

0

Q [m3/h]

H

[ft]0 10 20 30 40

0 10 20 30 40

50[m] U S G P M

3

4

5

6

7

8

930

0 1 2 3 4 5 6 7 8 9 10 11 120

0.1

0.2

13

0.3

0.1

0.2

0.4

0.3

0

Q [m3/h]

1.0

2.0

3.0

4.0

5.0

6.0

η 0.45

Ø 1 3 0

Ø 1 2 0

Ø 1 1 0

Ø 9 0

Ø 1 0 0

η 0.50

η 0.35 η 0.40

IGPM

Ø 8 0

Ø 1 0 0

Ø 1 1 0

Ø 1 2 0

Ø 9 0

Ø 8 0

Ø 8 0

Ø 1 3 0

Ø 1 3 0

η 0.25

Performance curves, centrifugal pump, TP 1020 (4-polig / 60 Hz)

Selected valuesdetermined by thepump selected

Selection using thecharacteristic curves

TP01020460080

009

Designation Code of selection characteristicsPosExample

Impeller diameter

Required motor power

Required NPSH-value

Motor output selection inaccordance with capacity

and pump head

Impeller selection inaccordance with capacity

and pump head

Standard version, for other versions see options

PositionND654

01 0 2 0 4263

0PT1

Code 085 0N

7F K 0 4 0

9 10E K E - 1

111213-14

J15

J16

-17

Page 82: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

82

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 1020, 4-pole (n=1,750 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 10202. Speed 4 = 4 pole3. Frequency 60 = 60 Hz4. Impeller 080 = 80 mm 100 = 100 mm 120 = 120 mm 090 = 90 mm 110 = 110 mm 130 = 130 mm5. Motor power 007 = 0.75 kW (IEC 80) 012 = 1.25 kW (IEC 90S) 018 = 1.8 kW (IEC 90L) 022 = 2.2 kW (IEC 100L)

TP01020460080

007

Designation Code of selection characteristicsPosExample

PositionND654

01 0 2 0 4263

0PT1

Code 085 0N

7F K 0 4 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max 11 m³/h

Pump head max. 8 m w.c.

Housing pressure max. 10 bar

TP 1020 Motor size b c** d f h m n p t* u v w x y*

80 484 390 144 285 352 76 228 125 25.5 92 125 82 14 25.5

90S / 90L 490 425 144 285 352 76 228 140 25.5 90 125 82 14 25.5

100L 602 474 154 335 403 76 278 160 25.5 112 125 85 14 25.5

Page 83: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

83

GEA Tuchenhagen

Standard TP

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 1020, 4-pole (n=1,750 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 HzNPSH

[m]

P[kW]

0

[ft]

1 2 3 4 5 6 7 8 9 10 11 1200

1

2

0

0.5

1.0

1.5

2.0

25

20

15

5

0

Q [m3/h]1 2 3 4 5 6 7 8 9 10 11 12

13

13

10

η 0.30

[hp]

0

Q [m3/h]

H

[ft]0 10 20 30 40

0 10 20 30 40

50[m] U S G P M

3

4

5

6

7

8

930

0 1 2 3 4 5 6 7 8 9 10 11 120

0.1

0.2

13

0.3

0.1

0.2

0.4

0.3

0

Q [m3/h]

1.0

2.0

3.0

4.0

5.0

6.0

η 0.45

Ø 1 3 0

Ø 1 2 0

Ø 1 1 0

Ø 9 0

Ø 1 0 0

η 0.50

η 0.35 η 0.40

IGPM

Ø 8 0

Ø 1 0 0

Ø 1 1 0

Ø 1 2 0

Ø 9 0

Ø 8 0

Ø 8 0

Ø 1 3 0

Ø 1 3 0

η 0.25

60 Hz

4-pole

Page 84: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

84

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 1540, 4-pole (n=1,750 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 15402. Speed 4 = 4 pole3. Frequency 60 = 60 Hz4. Impeller 130 = 130 mm 140 = 140 mm 145 = 145 mm 150 = 150 mm 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm5. Motor power 007 = 0.75 kW (IEC 80) 012 = 1.25 kW (IEC 90S) 018 = 1.8 kW (IEC 90L) 022 = 2.2 kW (IEC 100L)

TP01540460130

007

Designation Code of selection characteristicsPosExample

PositionND654

01 5 4 0 4263

0PT1

Code 086 5N

7F K 0 4 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 40

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 22 m³/h

Pump head max. 15,5 m w.c.

Housing pressure max. 16 bar

TP 1540 Motor size b c** d f h m n p t* u v w x y*

80 490 396 121.5 285 352 90 228 125 25.5 92 140 82 42 25.5

90S / 90L 496 431 121.5 285 352 90 228 140 25.5 90 140 82 42 25.5

100L 608 480 131.5 335 403 90 278 160 25.5 112 140 85 42 25.5

Page 85: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

85

GEA Tuchenhagen

Standard TP

Standard TPS

Performance curves, centrifugal pump, type TP 1540, 4-pole (n=1,750 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 Hz

H

[m][ft]

NPSH[m]

P[kW]

USGPM0

0

[ft]

2 4 6 8 10 12 14 16 18 20 22 2400

2

4

6

8

10

12

16

0

1

2

3

4

0

20 40 60 80

0 20 40 60 80

50

40

30

10

10

0

14

2 4 6 8 10 12 14 16 18 20 22 24

2 4 6 8 10 12 14 16 18 20 22 240.2

0.4

0.6

0.8

1.0

1.2

26

26

26

100

5

20

1.4

12.5

2.5

7.5

[hp]

0

Q [m3/h]

Q [m3/h]

Q [m3/h]

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

IGPM

Ø 1 3 0

Ø 1 4 0

Ø 1 5 0

Ø 1 6 0

Ø 1 7 0

Ø 1 8 0

η 0.57

η 0.55η 0.50η 0.45η 0.35η 0.30 η 0.40

Ø 1 3 0 Ø 1 8 0

Ø 1 8 0

Ø 1 7 0

Ø 1 6 0

Ø 1 5 0

Ø 1 4 0Ø 1 3 0

Required NPSH-value

Impeller diameter

Required motor power

60 Hz

4-pole

Page 86: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

86

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 2030, 4-pole (n=1,750 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 20302. Speed 4 = 4 pole3. Frequency 60 = 60 Hz4. Impeller 110 = 110 mm 120 = 120 mm 130 = 130 mm 140 = 140 mm 145 = 145 mm 150 = 150 mm 155 = 155 mm 160 = 160 mm5. Motor power 007 = 0.75 kW (IEC 80) 012 = 1.25 kW (IEC 90S) 018 = 1.8 kW (IEC 90L) 022 = 2.2 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 132S)

TP02030460110

007

Designation Code of selection characteristicsPosExample

PositionND654

02 0 3 0 4263

0PT1

Code 085 0N

7F K 0 4 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 23 m³/h

Pump head max. 13 m w.c.

Housing pressure max. 16 bar

TP 2030

Motor size b c** d f h m n p t* u v w x y*

80 488 394 121.5 285 352 85 228 125 25.5 92 135 82 40 25.590S / 90L 494 429 121.5 285 352 85 228 140 25.5 90 135 82 40 25.5100L 606 478 131.5 335 403 85 278 160 25.5 112 135 85 40 25.5112M 606 500 131.5 335 403 85 278 190 25.5 112 135 85 40 25.5132S 707 557 152 410 444 85 332 216 25.5 132 135 85 40 25.5

Page 87: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

87

GEA Tuchenhagen

Standard TP

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 2030, 4-pole (n=1,750 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 Hz

H

[ft]

NPSH[m]

P[kW]

0

0

[ft]

2 4 6 8 10 12 14 16 18 20 22 2400

2

4

6

8

10

12

16

0

1

2

3

4

0

20 40 60 80

0 20 40 60 80

50

40

30

10

10

0

Q [m3/h]

14

2 4 6 8 10 12 14 16 18 20 22 24

2 4 6 8 10 12 14 16 18 20 22 240.2

0.4

0.6

0.8

1.0

1.2

26

26

26

100

5

20

1.4

12.5

2.5

7.5

η 0.30

η 0.60

0.4

0.6

0.8

1.0

1.4

1.2

1.8

1.6

[hp]

0

[m]

0.2

U S G P M

Q [m3/h]

Q [m3/h]

η 0.45

IGPM

Ø 1 6 0

Ø 1 5 0

Ø 1 4 0

Ø 1 2 0

Ø 1 3 0

Ø 1 1 0

η 0.50 η 0.55

η 0.35

η 0.40

Ø 1 1 0 Ø 1 6 0

Ø 1 6 0

Ø 1 1 0Ø 1 2 0

Ø 1 3 0Ø 1 4 0

Ø 1 5 0

60 Hz

4-pole

Page 88: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

88

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 2050, 4-pole (n=1,750 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 20502. Speed 4 = 4 pole3. Frequency 60 = 60 Hz4. Impeller 160 = 160 mm 170 = 170 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm5. Motor power 007 = 0.75 kW (IEC 80) 012 = 1.25 kW (IEC 90S) 018 = 1.8 kW (IEC 90L) 022 = 2.2 kW (IEC 100L) 040 = 4.0 kW (IEC 112M)

TP02050460160

007

Designation Code of selection characteristicsPosExample

PositionND654

02 0 5 0 4263

0PT1

Code 086 5N

7F K 0 5 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 21 m³/h

Pump head max. 22 m w.c.

Housing pressure max. 16 bar

TP 2050

Motor size b c** d f h m n p t* u v w x y*

80 504 410 126 285 352 107 228 125 25.5 90 161 82 52 25.590S / 90L 510 445 126 285 352 107 228 140 25.5 90 161 82 52 25.5100L 622 494 136 335 403 107 278 160 25.5 112 161 85 52 25.5112M 622 516 136 335 403 107 278 190 25.5 112 161 85 52 25.5

Page 89: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

89

GEA Tuchenhagen

Standard TP

Standard TPS

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 2050, 4-pole (n=1,750 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 Hz

H[m][ft]

NPSH[m]

P[kW]

0

USGPM0

0

[ft]

2 4 6 8 10 12 14 16 18 20 22 2400

4

8

12

16

20

24

28

0

0.5

1

1.5

2

1

2

0

25 50 75 100

0 12.5 25 37.5 50 62.5 75 87.5

10

5

2.5

0

Q [m3/h]26

[hp]

0

0.5

1

2

20

30

100

1.5

2.5

Q [m3/h]

Q [m3/h]

0

40

50

60

70

80

12.5 37.5 62.5 87.5

IGPM

η 0.40η 0.45

Ø 1 6 0 Ø 2 1 0

η 0.50

Ø 1 6 0

Ø 2 1 0

Ø 2 0 0

Ø 1 7 0Ø 1 8 0

Ø 1 9 0

η 0.45η 0.40

η 0.52

η 0.52

Ø 2 1 0Ø 2 0 0

Ø 1 7 0Ø 1 8 0

Ø 1 9 0

Ø 1 6 0

2 4 6 8 10 12 14 16 18 20 22 24 26

2 4 6 8 10 12 14 16 18 20 22 24 26

η 0.45

η 0.50

Impeller diameter

60 Hz

4-pole

Page 90: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

90

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 2575, 4-pole (n=1,750 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 25752. Speed 4 = 4 pole3. Frequency 60 = 60 Hz4. Impeller 200 = 200 mm 210 = 210 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm 230 = 230 mm 235 = 235 mm 240 = 240 mm 245 = 245 mm 250 = 250 mm5. Motor power 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 132S) 075 = 7.5 kW (IEC 132M)

TP02575460200

040

Designation Code of selection characteristicsPosExample

PositionND654

02 5 7 5 4263

0PT1

Code 086 5N

7F K 0 5 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 22 m³/h

Pump head max. 31 m w.c.

Housing pressure max. 16 bar

TP 2575 Motor size b c** d f h m n p t* u v w x y*

112M 621 515 138 335 403 124.5 278 190 25.5 112 190 85 48.5 25.5

132S / 132M 720 570/630 156 410 444 124.5 332 216 25.5 132 190 85 48.5 25.5

Page 91: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

91

GEA Tuchenhagen

Standard TP

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 2575, 4-pole (n=1,750 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 Hz

H

[m][ft]

NPSH[m]

P[kW]

USGPM0

0

[ft]

2 4 6 8 10 12 14 16 18 20 22 2400

4

8

20

24

32

0

0.5

1

1.5

2

0

20 40 60 80

0 20 40 60 80

80

60

20

0

28

2 4 6 8 10 12 14 16 18 20 22 24

2 4 6 8 10 12 14 16 18 20 22 240.5

1.0

1.5

2.0

2.5

3.0

26

26

26

100

40

3.5

2

[hp]

0

Q [m3/h]

Q [m3/h]

Q [m3/h]

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

16

12

100

5.0

4

6

IGPM

η 0.46η 0.46

Ø 2 4 0

Ø 2 5 0

Ø 2 0 0

Ø 2 5 0

Ø 2 5 0

Ø 2 4 0

Ø 2 3 0

Ø 2 2 0

Ø 2 1 0Ø 2 0 0

Ø 2 3 0

Ø 2 2 0

Ø 2 1 0

Ø 2 0 0 η 0.48

η 0.35

η 0.35

η 0.40

η 0.40

η 0.44

η 0.44

η 0.44

60 Hz

4-pole

Page 92: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

92

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 3050, 4-pole (n=1,750 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 30502. Speed 4 = 4 pole3. Frequency 60 = 60 Hz4. Impeller 140 = 140 mm 150 = 150 mm 160 = 160 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm5. Motor power 007 = 0.75 kW (IEC 80) 012 = 1.25 kW (IEC 90S) 018 = 1.8 kW (IEC 90L) 022 = 2.2 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 132S) 075 = 7.5 kW (IEC 132M)

TP03050460140

007

Designation Code of selection characteristicsPosExample

PositionND654

03 0 5 0 4263

0PT1

Code 086 5N

7F K 0 5 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 42 m³/h

Pump head max. 24 m w.c.

Housing pressure max. 16 bar

TP 3050

Motor size b c** d f h m n p t* u v w x y*

80 500 406 124 285 352 103 228 125 25.5 92 155 82 50 25.590S / 90L 506 441 124 285 352 103 228 140 25.5 90 155 82 50 25.5100L 618 490 134 335 403 103 278 160 25.5 112 155 85 50 25.5112M 618 512 134 335 403 103 278 190 25.5 112 155 85 50 25.5

132S / 132M 719 569/609 154 410 444 103 332 216 25.5 132 155 85 50 25.5

Page 93: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

93

GEA Tuchenhagen

Standard TP

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 3050, 4-pole (n=1,750 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 Hz

H

[m][ft]

NPSH[m]

P[kW]

0

USGPM0

0

[ft]

4 8 12 16 20 24 28 32 36 40 44 4800

4

8

12

16

20

24

28

4 8 12 16 20 24 28 32 36 40 44 480

1

2

3

4

1

2

3

4

4 8 12 16 20 24 28 32 36 40 44 480

25 50 75 100 125 150 175 200

0 25 50 75 100 125 150 175

10

10

5

0

Q [m3/h]

225

52

52

52

[hp]

0

1

2

4

20

30

100

3

5

Q [m3/h]

Q [m3/h]

0

40

50

60

70

80

IGPM

η 0.40 η 0.45

Ø 2 1 0

Ø 2 0 0

Ø 1 4 0

Ø 1 7 0Ø 1 8 0

Ø 1 4 0Ø 2 1 0

Ø 1 9 0

η 0.60

η 0.50Ø 1 6 0

Ø 2 1 0

Ø 2 0 0

Ø 1 7 0

Ø 1 8 0

Ø 1 9 0

Ø 1 5 0

Ø 1 4 0

η 0.45

η 0.40

η 0.55

η 0.55

η 0.61

Ø 1 6 0Ø 1 5 0

η 0.60

60 Hz

4-pole

Page 94: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

94

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 5060, 4-pole (n=1,750 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 50602. Speed 4 = 4 pole3. Frequency 60 = 60 Hz4. Impeller 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm5. Motor power 022 = 2.2 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 132S) 075 = 7.5 kW (IEC 132M)

TP05060460155

022

Designation Code of selection characteristicsPosExample

PositionND654

05 0 6 0 4263

0PT1

Code 088 0N

7F K 0 6 5

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 45 m³/h

Pump head max. 24 m w.c.

Housing pressure max. 16 bar

TP 5060

Motor size b c** d f h m n p t* u v w x y*

100L 622 494 137 335 403 114.5 278 160 27.5 112 230 85 51 25.5112M 622 516 137 335 403 114.5 278 190 27.5 112 230 85 51 25.5

132S / 132M 723 573/613 157 410 444 114.5 332 216 27.5 132 230 85 51 25.5

Page 95: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

95

GEA Tuchenhagen

Standard TP

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 5060, 4-pole (n=1,750 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 Hz

H

[m][ft]

NPSH[m]

P[kW]

0

USGPM0

0

[ft]

4 8 12 16 20 24 28 32 36 40 44 4800

5

10

15

20

25

30

35

4 8 12 16 20 24 28 32 36 40 44 480

1

2

3

4

0.5

4 8 12 16 20 24 28 32 36 40 44 480

25 50 75 100 125 150 175 200

0 25 50 75 100 125 150 175

100

25

5

0

Q [m3/h]

225

52

52

52

[hp]

0

1

2

4

50

75

3

Q [m3/h]

Q [m3/h]

0

5

5

6

7.5

1.0

1.5

2.0

2.5

2.5

IGPM

Ø 1 7 5

Ø 2 1 5

Ø 1 8 5

Ø 1 9 5

Ø 2 0 5η 0.62

η 0.50

Ø 2 1 5

Ø 2 0 5

Ø 1 6 5Ø 1 7 5

Ø 1 8 5

Ø 1 9 5

Ø 2 2 5

Ø 2 2 5

Ø 1 6 5

Ø 1 5 5

η 0.58

η 0.58

η 0.55

η 0.55

η 0.50

η 0.40 η 0.45

η 0.45

η 0.40

Ø 2 2 5

Ø 1 5 5

Ø 1 5 5

60 Hz

4-pole

Page 96: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

96

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 7060, 4-pole (n=1,750 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 70602. Speed 4 = 4 pole3. Frequency 60 = 60 Hz4. Impeller 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm5. Motor power 022 = 2.2 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 132S) 075 = 7.5 kW (IEC 132M)

TP07060460155

022

Designation Code of selection characteristicsPosExample

PositionND654

07 0 6 0 4263

0PT1

Code 088 0N

7F K 0 6 5

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 65 m³/h

Pump head max. 27 m w.c.

Housing pressure max. 16 bar

TP 7060

Motor size b c** d f h m n p t* u v w x y*

100L 622 494 132 335 427 110 278 160 27.5 112 230 85 56 25.5112M 622 516 132 335 427 110 278 190 27.5 112 230 85 56 25.5

132S / 132M 723 573/613 152 410 444 110 332 216 27.5 132 230 85 56 25.5

Page 97: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

97

GEA Tuchenhagen

Standard TP

Standard TPS

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 7060, 4-pole (n=1,750 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 Hz

H[m][ft]

NPSH[m]

USGPM

0

0.5

1.0

1.5

2.0

[ft]

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 750

0

70

60

50

30

20

10

0

6.0

4.0

2.0

0

Q [m3/h]

5

10

15

20

25

40

80

25 50 75 100 125 150 175 200 225 250 275 300 325

25 50 75 100 125 150 175 200 225 250

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75P

[kW]

0

Q [m3/h]

Q [m3/h]0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75

1.0

2.0

3.0

4.0

5.0

0

[hp]

0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

6.0

7.0

8.0

9.0

10.0

IGPM30

90

100

2.5

3.0

8.0

10.0

3.512.0

Ø215

Ø225

Ø205

Ø195

Ø185

Ø175

Ø165

Ø155Ø225

Ø225

Ø215

Ø205

Ø195Ø185

Ø175Ø165

η 0.66

η 0.65

η 0.50

η 0.50

η 0.60

Ø155

Ø155

η 0.60η 0.55

η 0.55

Impeller diameter

60 Hz

4-pole

Page 98: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

98

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 8080, 4-pole (n=1,750 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 80802. Speed 4 = 4 pole3. Frequency 60 = 60 Hz4. Impeller 180 = 180 mm 190 = 190 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm 230 = 230 mm 235 = 235 mm 240 = 240 mm 245 = 245 mm 250 = 250 mm5. Motor power 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 132S) 075 = 7.5 kW (IEC 132M)

TP08080460180

040

Designation Code of selection characteristicsPosExample

PositionND654

08 0 8 0 4263

0PT1

Code 180 0N

7F K 0 6 5

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 100; Pressure port (DS), DN 65

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 75 m³/h

Pump head max. 34 m w.c.

Housing pressure max. 16 bar

TP 8080 Motor size b c** d f h m n p t* u v w x y*

112M 641 535 136 335 403 124 278 190 27.5 112 250 85 71 25.5

132S / 132M 742 592/632 156 410 444 124 332 216 27.5 132 250 85 71 25.5

Page 99: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

99

GEA Tuchenhagen

Standard TP

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TP 8080, 4-pole (n=1,750 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 Hz

H

[m][ft]

NPSH[m]

USGPM

0

0.5

1.0

1.5

2.0

1.5[ft]

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 750

0

0

80

60

20

0

6.0

4.0

2.0

0

Q [m3/h]

2

10

20

26

40

90

25 50 75 100 125 150 175 200 225 250 275 300 325

25 50 75 100 125 150 175 200 225 250

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75P

[kW]

0

Q [m3/h]

Q [m3/h]0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75

2.0

4.0

6.0

8.0

10

4

6

8

12

14

16

18

22

24

28

30

32

0

2.0

4.0

6.0

8.0

10

12

14

[hp]

34

IGPM275

80

80

80

η 0.64

η 0.60

η 0.55

Ø250

Ø250

Ø240

Ø230

Ø220

Ø190

Ø180

Ø180

Ø200

Ø250

Ø240

η 0.66

η 0.60η 0.55η 0.50

η 0.50

η 0.40 η 0.45

Ø230Ø220

Ø190Ø180

Ø200

Ø210

Ø210

60 Hz

4-pole

Page 100: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

100

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TP 16040, 4-pole (n=1,750 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TP 160402. Speed 4 = 4 pole3. Frequency 60 = 60 Hz4. Impeller 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 5. Motor power 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 132S) 075 = 7.5 kW (IEC 132M)

TP16040460160

040

Designation Code of selection characteristicsPosExample

PositionND654

06 0 4 0 4263

1PT1

Code 185 0N

7F K 1 0 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 150; Pressure port (DS), DN 100

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 120 m³/h

Pump head max. 17 m w.c.

Housing pressure max. 16 bar

TP 16040 Motor size b c** d f h m n p t* u v w x y*

112M 651 545 131 335 403 108 278 190 29.5 112 280 85 86 27.5

132S / 132M 752 602/642 151 410 444 108 332 216 29.5 132 280 85 86 27.5

Page 101: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

101

GEA Tuchenhagen

Standard TP

Standard TPSRe

quired NPSH-value

Performance curves, centrifugal pump, type TP 16040, 4-pole (n=1,750 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 HzNPSH

[m]

P[kW]

0

[ft]

00

0

1

2

3

4

0

40

30

10

10

0

Q [m3/h]

1

5

20

12.5

2.5

7.5

[hp]

0

0

Q [m3/h]

Q [m3/h]

0

2

10

12

14

16

18

4

6

8

10 20 30 40 100 110 120 13050 60 70 80 90

10 20 30 40 100 110 120 13050 60 70 80 90

2

3

4

5

6

10 20 30 40 100 110 120 13050 60 70 80 90

515

50

60

1

2

3

4

5

6

7

8

150

H

[ft]0 75

50

525[m] U S G P M

500450400350300250200100

600450400325250175

Ø 2 0 0

Ø 1 9 0

Ø 1 7 0

Ø 1 6 0

η 0.45

η 0.50

η 0.40

Ø 1 8 0

Ø 1 9 0

Ø 2 0 0

Ø 1 7 0Ø 1 6 0

Ø 1 8 0

η 0.50

η 0.55

η 0.60

η 0.65

η 0.65η 0.55 η 0.60

η 0.67

Ø 2 0 0

Ø 1 6 0

IGPM

Impeller diameter

Required motor power

60 Hz

4-pole

Page 102: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

50 Hz

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 850

10

20

30

40

50

60

70250

200

150

100

50

0

Q [m3/h]

H[m][ft] USGPM

0 50 100 150 200 250 300 350

300250200150100500 IGPM

TPS 3050

TPS 2030

102

GEA Tuchenhagen

Performance characteristics 50 Hz, GEA Tuchenhagen®-VARIFLOW, Baureihe TPS

2-pole (n = 2,900 min-1)

Page 103: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

60 Hz

103

GEA Tuchenhagen

Standard TPS

Performance characteristics 60 Hz, GEA Tuchenhagen®-VARIFLOW, Baureihe TPS

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 850

10

20

30

40

50

60

70

80

90300

250

200

150

100

50

0

Q [m3/h]

H[m][ft] USGPM

0 50 100 150 200 250 300 350

300250200150100500

100

110350

IGPM

400

90

TPS 3050

TPS 2030

2-pole (n = 3,500 min-1)

Page 104: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

50 Hz

104

GEA Tuchenhagen

Standard version, centrifugal pump, type TPS, 2-pole (n=2,900 min-1), 50 Hz

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 850

10

20

30

40

50

60

70250

200

150

100

50

0

Q [m3/h]

H[m][ft] USGPM

0 50 100 150 200 250 300 350

300250200150100500 IGPM

TPS 3050

TPS 2030

Performance characteristicsTPS

2-pole (n=2,900 min-1), 50 Hz

Standard version 2 pole/50Hz

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Depending on pump size

Mechanical seal Single-acting, material: C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Standard equipment Stainless steel protection hood and base frame with height-adjustable

calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F, incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 55 m3/h

Pump head max. 64 m w.c.

TPS 2030 und TPS 3050

Page 105: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

105

GEA Tuchenhagen

50 Hz

2-pole

Standard TPS

1. Type TPS 20302. Speed 2 = 2 pole3. Frequency 50 = 50 Hz4. Impeller 110 = 110 mm 120 = 120 mm 130 = 130 mm 140 = 140 mm 145 = 145 mm 150 = 150 mm 155 = 155 mm 160 = 160 mm5. Motor power 022 = 2.2 kW (IEC 90L) 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 112M) 075 = 7.5 kW (IEC 112M) 110 = 11.0 kW (IEC 132M)

Example of a standard selection

50 Hz50 Hz

H

44

40

36

32

28

24

20

16

12

8

4

[m][ft]

NPSH[m]

[kW]

1.0

1.5

2.0

2.5

3.0

3.5

4.0

USGPM0

0

[ft]

0

2

4

6

0

0 5 10 15 20 25 30 35

20 40 60 80 100 120 140

0 20 40 60 80 100 120

140

120

100

80

60

40

20

0

40

160

140

5 10 15 20 25 30 35Q [m3/h]

40

0 5 10 15 20 25 30 35Q [m3/h]

40

4.5

5.0

8

10

0

30

2.0

3.0

4.0

5.0

6.0

[hp]P

40

1.0

5.57.0

Q [m3/h]

10

20

12

IGPM

Ø110

Ø160

Ø160

Ø150

Ø140

Ø130

Ø120

η 0.35

η 0.30

Ø160

Ø150

Ø140

Ø130

Ø120Ø110

η 0.30

η 0.35

η 0.25

η 0.25

η 0.20

η 0.20

Ø110

η 0.37

η 0.37

Performance curves, centrifugal pump, TPS 2030 (2-polig / 50 Hz)

Selected valuesdetermined by thepump selected

Selection using thecharacteristic curves

TPS 2030250110

022

Designation Code of selection characteristicsPosExample

Impeller diameter

Required motor power

Required NPSH-value

Motor output selection inaccordance with capacity

and pump head

Impeller selection inaccordance with capacity

and pump head

Standard version, for other versions see options

PositionND654

02 0 3 0 2253

SPT1

Code 086 5N

7F K 0 4 0

9 10E K E - 1

111213-14

J15

J16

-17

Page 106: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 40

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 32 m³/h

Pump head max. 37 m w.c.

Housing pressure max. 16 bar

106

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TPS 2030, 2-pole (n=2,900 min-1), 50 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TPS 20302. Speed 2 = 2 pole3. Frequency 50 = 50 Hz4. Impeller 110 = 110 mm 120 = 120 mm 130 = 130 mm 140 = 140 mm 145 = 145 mm 150 = 150 mm 155 = 155 mm 160 = 160 mm5. Motor power 022 = 2.2 kW (IEC 90L) 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 112M) 075 = 7.5 kW (IEC 112M) 092 = 9.2 kW (IEC 132M) 110 = 11.0 kW (IEC 132M)

TPS2030250110

022

Designation Code of selection characteristicsPosExample

PositionND654

02 0 3 0 2253

SPT1

Code 086 5N

7F K 0 4 0

9 10E K E - 1

111213-14

J15

J16

-17

TP 2030

Motor size b c** d f h m n p t* u v w x y*

90L 594 529 121.5 285 352 85 227 140 25.5 80 135 82 140.5 25.5100L 706 578 131.5 335 403 85 227 160 25.5 90 135 85 140.5 25.5

112M (4 kW + 5.5 kW) 706 600 131.5 335 403 85 227 190 25.5 102 135 85 140.5 25.5112M (7.5 kW) 706 622 131.5 335 403 85 227 190 25.5 102 135 85 140.5 25.5

132M 808 717.5 152 410 444 85 332 216 25.5 122 135 85 140.5 25.5

Page 107: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

107

GEA Tuchenhagen

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TPS 2030, 2-pole (n=2,900 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

50 Hz50 Hz

H

44

40

36

32

28

24

20

16

12

8

4

[m][ft]

NPSH[m]

[kW]

1.01.52.02.53.03.54.0

USGPM0

0

[ft]

0

246

0

0 5 10 15 20 25 30 35

20 40 60 80 100 120 140

0 20 40 60 80 100 120

140

120

100

80

60

40

20

0

40

160

140

5 10 15 20 25 30 35Q [m3/h]

40

0 5 10 15 20 25 30 35Q [m3/h]

40

4.55.0

8

10

0

30

2.0

3.0

4.0

5.0

6.0

[hp]P

40

1.0

5.57.0

Q [m3/h]

10

20

12

IGPM

Ø 1110Ø 160

Ø 160

Ø 150

Ø 140

Ø 130

Ø 120

Ø 160

Ø 150

Ø 140Ø 130

Ø 120Ø 110

Ø 110

η 0.35

η 0.30

η 0.30

η 0.35

η 0.25

η 0.25

η 0.20

η 0.20

η 0.37

η 0,37

50 Hz

2-pole

Page 108: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 55 m³/h

Pump head max. 64 m w.c.

Housing pressure max. 16 bar

108

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TPS 3050, 2-pole (n=2,900 min-1), 50 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TPS 30502. Speed 2 = 2 pole3. Frequency 50 = 50 Hz4. Impeller 140 = 140 mm 150 = 150 mm 160 = 160 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm5. Motor power 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 112M) 075 = 7.5 kW (IEC 112M) 092 = 9.2 kW (IEC 132M) 110 = 11.0 kW (IEC 132M) 150 = 15.0 kW (IEC 132M) 185 = 18.5 kW (IEC 160L) 220 = 22.0 kW (IEC 160L)

TPS3050250140

030

Designation Code of selection characteristicsPosExample

PositionND654

03 0 5 0 2253

SPT1

Code 086 5N

7F K 0 5 0

9 10E K E - 1

111213-14

J15

J16

-17

TP 3050

Motor size b c** d f h m n p t* u v w x y*

100L 729 600.5 133 335 403 103 227 160 25.5 90 155 85 161.5 25.5112M (4 kW + 5.5 kW) 729 622.5 133 335 403 103 227 190 25.5 102 155 85 161.5 25.5

112M (7.5 kW) 729 644.5 133 335 403 103 227 190 25.5 102 155 85 161.5 25.5132 M 830 740 153 410 444 103 332 216 25.5 122 155 85 161.5 25.5160 L 999 886.5 183 640 598 103 408 254 25.5 150 155 110 161.5 25.5

Page 109: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

109

GEA Tuchenhagen

Standard TPS

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TPS 3050, 2-pole (n=2,900 min-1), 50 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

50 Hz50 Hz[m]

P[kW]

0

5

10

15

20

00 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85

2

4

6

8

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85

30

20

0

Q [m3/h]

Q [m3/h]0

5

10

15

20

25

[hp]

NPSH[ft]

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 850

10

20

30

40

50

60

70250

200

150

100

50

0

Q [m3/h]

H[m][ft] USGPM

0 50 100 150 200 250 300 350

300250200150100500 IGPM

40

10

10

12

Ø 210

Ø 200Ø 190

Ø 140

Ø 180Ø 170

Ø 2 1 0

Ø 1 4 0

Ø 160Ø 150

Ø 2 1 0

Ø 1 4 0

Ø 2 0 0

Ø 1 9 0Ø 1 8 0Ø 1 7 0Ø 1 6 0Ø 1 5 0

η 0.40η 0.42 η 0.44

η 0.35η 0.30

η 0.25

η 0.42

η 0.40

η 0.35

η 0.30

η 0.25

Impeller diameter

50 Hz

2-pole

Page 110: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

60 Hz

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 850

10

20

30

40

50

60

70

80

90300

250

200

150

100

50

0

Q [m3/h]

H[m][ft] USGPM

0 50 100 150 200 250 300 350

300250200150100500

100

110350

IGPM

400

90

TPS 3050

TPS 2030

110

GEA Tuchenhagen

Standard version, centrifugal pump, type TPS, 2-pole (n=3,500 min-1), 60 Hz

Performance characteristicsTPS

2-pole (n=3,500 min-1), 60 Hz

Standard version 2 pole/60Hz

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Depending on pump size

Mechanical seal Single-acting, material: C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Standard equipment Stainless steel protection hood and base frame with height-adjustable

calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F, incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 69 m3/h

Pump head max. 95 m w.c.

TPS 2030 und TPS 3050

Page 111: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

111

GEA Tuchenhagen

60 Hz

2-pole

Standard TPS

1. Type TPS 20302. Speed 2 = 2 pole3. Frequency 60 = 60 Hz4. Impeller 110 = 110 mm 120 = 120 mm 130 = 130 mm 140 = 140 mm 145 = 145 mm 150 = 150 mm 155 = 155 mm 160 = 160 mm5. Motor power 022 = 2.2 kW (IEC 90L) 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 112M) 075 = 7.5 kW (IEC 112M) 110 = 11.0 kW (IEC 132M)

Example of a standard selection

60 Hz60 Hz

H

[m][ft]

NPSH[m]

P[kW]

0

USGPM0

0

[ft]

4 8 12 16 20 24 28 32 36 40 44 4800

8

16

24

32

40

48

56

4 8 12 16 20 24 28 32 36 40 44 480

2

4

6

8

10

2

4

6

8

4 8 12 16 20 24 28 32 36 40 44 480

25 50 75 100 125 150 175 200

0 25 50 75 100 125 150 175

100

25

20

0

Q [m3/h]

225

52

52

52

[hp]

0

2

4

8

50

75

125

150

175175

6

10

12

Q [m3/h]

Q [m3/h]

0

10

3010

IGPM

Ø 1 6 0

Ø 1 5 0

Ø 1 1 0Ø 1 2 0

Ø 1 3 0

Ø 1 1 0

Ø 1 6 0

Ø 1 4 0

η 0.35

Ø 1 1 0

Ø 1 5 0

Ø 1 2 0

Ø 1 3 0

Ø 1 4 0

Ø 1 6 0

η 0.35

η 0.37

η 0.30η 0.25

η 0.37

η 0.30

η 0.20

η 0.25

η 0.20

Performance curves, centrifugal pump, TPS 2030 (2-polig / 60 Hz)

Selected valuesdetermined by thepump selected

Selection using thecharacteristic curves

TPS2030260110

022

Designation Code of selection characteristicsPosExample

Impeller diameter

Required motor power

Required NPSH-value

Motor output selection inaccordance with capacity

and pump head

Impeller selection inaccordance with capacity

and pump head

Standard version, for other versions see options

PositionND654

02 0 3 0 2263

SPT1

Code 086 5N

7F K 0 4 0

9 10E K E - 1

111213-14

J15

J16

-17

Page 112: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

112

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TPS 2030, 2-pole (n=3,500 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TPS 20302. Speed 2 = 2 pole3. Frequency 60 = 60 Hz4. Impeller 110 = 110 mm 120 = 120 mm 130 = 130 mm 140 = 140 mm 145 = 145 mm 150 = 150 mm 155 = 155 mm 160 = 160 mm5. Motor power 022 = 2.2 kW (IEC 90L) 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 112M) 075 = 7.5 kW (IEC 112M) 110 = 11.0 kW (IEC 132M)

TPS2030260110

022

Designation Code of selection characteristicsPosExample

PositionND654

02 0 3 0 2263

SPT1

Code 086 5N

7F K 0 4 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 40

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 36 m³/h

Pump head max. 52 m w.c.

Housing pressure max. 16 bar

TP 2030

Motor size b c** d f h m n p t* u v w x y*

90L 594 529 121.5 285 352 85 227 140 25.5 80 135 82 140.5 25.5100L 706 578 131.5 335 403 85 227 160 25.5 90 135 85 140.5 25.5

112M (4 kW + 5.5 kW) 706 600 131.5 335 403 85 227 190 25.5 102 135 85 140.5 25.5112M (7.5 kW) 706 622 131.5 335 403 85 227 190 25.5 102 135 85 140.5 25.5

132M 808 717.5 152 410 444 85 332 216 25.5 122 135 85 140.5 25.5

Page 113: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

113

GEA Tuchenhagen

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TPS 2030, 2-pole (n=3,500 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 Hz

H[m][ft]

NPSH[m]

P[kW]

0

USGPM0

0

[ft]

4 8 12 16 20 24 28 32 36 40 44 4800

8

16

24

32

40

48

56

4 8 12 16 20 24 28 32 36 40 44 480

2

4

6

8

10

2

4

6

8

4 8 12 16 20 24 28 32 36 40 44 480

25 50 75 100 125 150 175 200

0 25 50 75 100 125 150 175

100

25

20

0

Q [m3/h]

225

52

52

52

[hp]

0

2

4

8

50

75

125

150

175175

6

10

12

Q [m3/h]

Q [m3/h]

0

10

3010

IGPM

Ø 1 6 0

Ø 1 5 0

Ø 1 1 0Ø 1 2 0

Ø 1 3 0

Ø 1 1 0

Ø 1 6 0

Ø 1 4 0

Ø 1 1 0

Ø 1 5 0

Ø 1 2 0

Ø 1 3 0

Ø 1 4 0

η 0.35

Ø 1 6 0

η 0.35

η 0.37

η 0.30η 0.25

η 0.37

η 0.30

η 0.20

η 0.25

η 0.20

60 Hz

2-pole

Page 114: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

114

GEA Tuchenhagen

All dimensions in mm

Standard version, centrifugal pump, type TPS 3050, 2-pole (n=3,500 min-1), 60 Hz

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width(**) Dimension c refers to our standard motors

1. Type TPS 30502. Speed 2 = 2 pole3. Frequency 60 = 60 Hz4. Impeller 140 = 140 mm 150 = 150 mm 160 = 160 mm 170 = 170 mm 175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm5. Motor power 030 = 3.0 kW (IEC 100L) 040 = 4.0 kW (IEC 112M) 055 = 5.5 kW (IEC 112M) 075 = 7.5 kW (IEC 112M) 110 = 11.0 kW (IEC 132M) 150 = 15.0 kW (IEC 132M) 212 = 21.2 kW (IEC 160L) 220 = 22.0 kW (IEC 160L)

TPS3050260140

030

Designation Code of selection characteristicsPosExample

PositionND654

03 0 5 0 2263

SPT1

Code 086 5N

7F K 0 5 0

9 10E K E - 1

111213-14

J15

J16

-17

Materials Pump housing, 316L (1.4404), deep-drawn

impeller, 316L (1.4409), precision casting

Connections DIN 11853-2 hygienic grooved flange (flange connection optional)

Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50

Mechanical seal Single-acting, material C / SIC / EPDM

Static seals EPDM (FDA, USP Class VI)

Equipment Stainless steel protection hood and base frame with

height-adjustable calotte-type feet

Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,

incl. thermistor, IE3

Documentation Operating instructions, declaration of conformity

Flow rate max. 69 m³/h

Pump head max. 95 m w.c.

Housing pressure max. 16 bar

TP 3050

Motor size b c** d f h m n p t* u v w x y*

100L 729 600.5 133 335 403 103 227 160 25.5 90 155 85 161.5 25.5112M (4 kW + 5.5 kW) 729 622.5 133 335 403 103 227 190 25.5 102 155 85 161.5 25.5

112M (7.5 kW) 729 644.5 133 335 403 103 227 190 25.5 102 155 85 161.5 25.5132 M 830 740 153 410 444 103 332 216 25.5 122 155 85 161.5 25.5160 L 999 886.5 183 640 598 103 408 254 25.5 150 155 110 161.5 25.5

Page 115: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

115

GEA Tuchenhagen

Standard TPS

Impeller diameter

Required motor power

Required NPSH-value

Performance curves, centrifugal pump, type TPS 3050, 2-pole (n=3,500 min-1), 60 Hz

The flow charts are based on a pumping medium of: densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

60 Hz60 HzNPSH

[m]

P[kW]

0

0

[ft]

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 850

10

20

30

40

50

60

70

80

90

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85

2

6

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85

300

250

200

150

100

50

0

40

20

0

Q [m3/h]

Q [m3/h]

Q [m3/h]

H[m][ft] USGPM

0 50 100 150 200 250 300 350

300250200150100500

100

110350

30

10

15

20

25

30

35

[hp]

10

15

20

25

30

5

IGPM

400

90

90

90

5

0

4

81012

10

Ø 210

Ø 1 4 0 Ø 2 1 0

Ø 200Ø 190

Ø 180Ø 170

Ø 160Ø 150

Ø 140

Ø 2 1 0

Ø 2 0 0

Ø 1 9 0

Ø 1 8 0

Ø 1 7 0

Ø 1 6 0Ø 1 5 0

Ø 1 4 0

η 0.35η 0.40

η 0.30η 0.25

η 0.42

η 0.44

η 0.35

η 0.30

η 0.25

η 0.42

η 0.40

60 Hz

2-pole

Page 116: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

116

GEA Tuchenhagen

Options for TP and TPS series

040 = DN 40 112 = 1.5" OD TP 1020 050 = DN 50 200 = 2" OD TP 1020 TP 2050 TP 2030 TP 3050 065 = DN 65 212 = 2.5" OD TP 1540 TP 2575 TP 7060 TP 2030 TP 3050 TPS 2030 TP 2050 TP 5060 TPS 3050 080 = DN 80 300 = 3" OD TP 1540 TP 3050 TP 8080 TP 2050 TP 5060 TP 2575 TP 7060 100 = DN 100 400 = 4" OD TP 8080 TP 16040 125 = DN 125 TP 16040 150 = DN 150 TP 16040 040 = DN 40 112 = 1.5" OD TP 1020 TP 2030 TP 1540 TPS 2030 050 = DN 50 200 = 2" OD TP 1020 TP 2050 TPS 2030 TP 1540 TP 2575 TPS 3050 TP 2030 TP 3050 065 = DN 65 212 = 2.5" OD TP 5060 TP 7060 TP 8080 080 = DN 80 300 = 3" OD TP 5060 TP 7060 TP 8080 100 = DN 100 400 = 4" OD TP 16040

Connection sizessuction side (SS)

Connection sizesPressure side (DS)

8.

9.

GSK

DesignationPosExample

NFK = Hygienic grooved flange DIN 11853-2 (standard)

ASK = Hygienic flange connection DIN 11853-2, cpl.

GO = Male partDIN 11851

GK = Pipe connectionDIN 11851, cpl.

TN = VARIVENT® grooved flangeTK = VARIVENT® flange connectionGSK = Hygienic male part

DIN 11853-1AVK = Hygienic union

DIN 11853-1, cpl.CO = Tri-Clamp analogous to

DIN 32676 / ISO 2852SMG =SMS male partSMK = SMS connection cpl.

Connection type *1)7.

*1) For TP 16040 on request*2) Versions available on request

40, 50,65, 80

100 125, 150 1.5“, 2“2.5“, 3“

4“DN DN DN OD OD

6. Nominal width DN = DIN 11850 standard OD = Zoll OD

Position 542 31Options

7 9 10 111213141516

Standard - - -N F K - E K E - 1 - J J -

176

ND

Code of selection characteristics

*2) *2)

*2) *2)

*2) *2)

*2) *2)

*2) *2) *2)

*2) *2) *2)

DN not available

DN not available

DN not available

Page 117: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

117

Options for TP and TPS series

GEA Tuchenhagen

Stan

dard TP

Options

Stan

dard TPS

Design / Material of mechanical seal

Static seals

Drainage

Product contactSurfaces

10.

11.

12.

13.

Explosion protectionclass*4)

Stainless steel protection

Calotte-type frame

Certificates

14.

15.

16.

17.

Designation Code of selection characteristicsPosExample

*3) 2 pieces for TPS Pumps*4) 30 kW ATEX on request

Position 542 31Options

87 9 10 111213141516

NStandard - - -N F K - E K E - 1 - J J -

17

TP 1020 TP 2575 TPS 2030

TP 1540 TP 5060 TPS 3050

TP 2030 TP 7060

TP 2050 TP 8080

TP 3050 TP 16040

Single-acting

EK = carbon / silicon carbide (standard)

EH = carbon / chrome molybdenum

ES = silicon carbide / silicon carbide

Single acting with flush

QK = with flush - carbon / silicon carbide

QH = with flush - carbon / chrome molybdenum

QS = with flush - silicon carbide / silicon carbide

Double-acting

PS = with flush - silicon carbide / silicon carbide

E = EPDM (Standard)

F = FKM

- = no drainage valve (standard)

D = drainage valve type VTP *3)

C = with drainage connection Tri-Clamp DN 15 *3)

(analogous to 32676 / ISO 2852)

1 = Ra ≤ 3.2µm (Standard)

3 = Ra ≤ 0.8µm electro-polished

PS

F

D

3

X

J

J

Z

- = without (standard)

X = with ATEX

(II2G Eex d IIB T4)

- = without (standard)

X = mit ATEX

(II2G Eex d IIB T4)

J = with (standard)

N = without

J = with (standard)

N = without

J = with (standard)

N = without

J = with (standard)

N = without

- = without (standard)

O = surface measurement report

Z = acceptance test certificate 3.1 DIN/EN 10204

6

D

Motor size 80 90S/90L 100L 112M 132S/132M

Motor size 160L 200L 225M

Motor size 80 90S/90L 100L 112M 132S/132M

Motor size 160L 200L 225M

Motor power 0.75 kW 1.1 kW 1.5 kW 2.2 kW 3.0 kW 4.0 kW 5.5 kW

Motor power 7.5 kW 11.0 kW 15.0 kW 18.5 kW 22.0 kW 30.0 kW 37.0 kW 45.0 kW

Page 118: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

Dairy union (DIN 11851-1)

Advantages of hygienic flange connection compared with dairy union

Drainage

Hygienic flange connection (DIN 11853-2)

118

GEA Tuchenhagen

Options for TP and TPS series

Single-acting, flushed (Quench)

mechanical seal

Single-acting (standard) mechanical seal

Slide ring holder, Second slide ring Shaft sealing ring and counter ring on both sides

and shaft protection sleeveCrystallizing and Hazardous,

highly viscous products (≥100 cP) abrasive and dilatant fluidsTwo sizes for the entire TP(S) program, easy to replace

Encapsulated spring, seal ring, counter ring, dead-space free

Mechanical seal design options

Drainage valve type VTP

For complete draining of the pump housing without any dead corners.Safe closing function, even in the eventof pressure surges in the system.

Drainage connector Tri-Clamp 1/2“, DN 15

Variable connection for individual draining

Double-acting mechanical seal

⊕Gap-free seal

⊕Defined defor-mation of seal

⊕Metallic stop

No gap-free seal

Undefined defor-mation of seal

No metallic stop

Page 119: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

119

Special versions for TP and TPS series on request

GEA Tuchenhagen

Standard TP

Standard TPS

VESTA® valves for drainingInducer for TP series

Heating jacket for TP series

Carriage for pump

Also available on request:

• Other connection types• Noise protection hood• Other motor designs and manufacturers

Options

Page 120: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

120

GEA Tuchenhagen

Part number Part numberTP 1020 244-000125 244-000128TP 1540 244-000126 244-000129TP 2030 244-000127 244-000130TP 2050 244-001024 244-001032TP 3050 244-000221 244-000222TP 5060 244-000458 244-000466TP 7060 244-001054 244-001055TP 2575 244-000467 244-000468TP 8080 244-000336 244-000384TP 16040 244-000519 244-000520TPS 2030 244-000696 244-000697TPS 3050 244-000785 244-000786

Pump type EPDM sealing set FKM sealing set

Sealing sets

Mechanical seals

Type Material Part number Part numberEW/QU* C/SIC/EPDM 244-000045 244-000345EW/QU* C/CrMo/EPDM 244-000531 244-000533EW/QU* SIC/SIC/EPDM 244-000043 244-000382EW/QU* C/SIC/FKM 244-000044 244-000381EW/QU* C/CrMo/FKM 244-000532 244-000534EW/QU* SIC/SIC/FKM 244-000042 244-000383DW SIC/SIC/EPDM 244-000135 244-000378DW SIC/SIC/FKM 244-000136 244-000379

Shaft seal 100-000014 924-342

ConfigurationTP 1020; TP(S) 2030; TP 1540;

TP 2050; TP(S) 3050TP 5060; TP 7060; TP 2575;

TP 8080; TP 16040

Mechanical seal Pump type

O-ring* O-ring*

O-ring* Mechanical seal

* included in sealing sets

TP Series

TPS Series

Sealing sets and mechanical seals

* For mechanical seal QU is recommended to change the shaft seal in addition

Page 121: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

Spare Parts

121

GEA Tuchenhagen

34

5

6

7

8

9

10

11

12

13

14

Flow parameters*Operating frequency(if not given "50Hz" assumed)

Fluid

Application*

Mechanical seals(if unknown no. 9 essential!)

Static seals(if unknown no. 9 essential!)

Fluid

Connections(suction and pressure nozzles)

Version

Actuator / Motor

Options

Marks / Other

1

2

Company / Cust. No:

Contact:

Phone: Fax: E-Mail:

Project / Tag No:

Flow rate: (m3/h) Pressure: bar

£ 50 Hz £ 60 Hz

Viscosity: Density:

(if not given "1 cP" assumed) (if not given "1 kg/dm3" assumed)

£ nonself-priming (TP Series) £ self-priming (TPS Series)

Execution: £ single acting (Standard) £ single flushed (Quench) £ double flushed

Material: £ C / SIC (Standard) £ SIC / SIC (double floushes only in SIC / SIC!)

Material: £ EPDM (Standard) £ FKM (Viton®)

Medium: Temperature: Viscosity:

£ Hygienic grooved flange DIN 11853-2 (standard) £ DIN 11853-2 (Hygienic flange) £ VARIVENT® flange

£ SMS £ other: £ complete, incl. counterpiece

£ with stainless steel cover £ stainless steel cover with acoustic insulation

£ with adjustable calotte feet or £ carrier without electrical connection

£ carrier with electrical connection

(incl. safety switch and 10 m cable and plug)

existing supply voltage £ 3~ 400V/50Hz (Europe) £ 3~ 460V/60Hz

£ 3~ 200V/60Hz (e.g. Japan) £ 3~ 200V/50Hz (e.g. Japan)

£ 3~ 380V/60Hz (e.g. Brazil) £ other:

Manufacturer: £ GEA Tuchenhagen Standard or £ ABB

Protection class: R IP 55 (Standard)

ATEX: £ II G Eex d IIB T4 or £ II G Eex de IIB T4

Adjustment control:R Thermistor (PTC) (Standard)

Surface: £ matt blank (Standard) £ Ra ≤ 0.8 µm

(Product contacted)

Drain: £ Drainvalve VTP or £ Drainpipe

DN 15 with TriClamp

Heating: £ Heating- or cooling jackets

Certificates: £ 3.1 Certificate DIN/EN 10204 £ Performance test certificate

£ Surface measurement report

Gasket selection

Pump performance

The checklist can also be found on www.tuchenhagen.com

Standard TP

Standard TPS

* Please fill out all required fields

GEA Mechanical Equipment

GEA Tuchenhagen GmbH

Am Industriepark 2-10, 21514 Büchen

Phon +49-4155 49-0, Fax +49-4155 49-2428

[email protected]

www.tuchenhagen.com

PumpsChecklist

Page 122: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

122

Any contract placed with us (hereinafter referred to as “theSeller”) by any private-law corporation, company or otherbusiness or any public-law legal person or other entity(hereinafter referred to as “the Buyer”) shall exclusively besubject to these Standard Sales Terms and these Standard SalesTerms shall be applicable to any transaction agreed between theSeller and the Buyer thereafter even if no express reference tothese Standard Sales Terms is made in connection with anysuch further transaction. The Seller hereby expressly refuses toaccept any standard terms of the Buyer referred to in anycorrespondence or other document placing any such order.Notwithstanding any reference of the Buyer to any standardterms of the Buyer, the Buyer shall, upon the acceptance of anydelivery by the Seller to the Buyer, be deemed to have acceptedthese Standard Sales Terms. No standard terms of the Buyershall be applicable to any contract or order placed by the Buyerwith the Seller unless such terms have been accepted expresslyby the Seller in writing and the performance of any suchcontract or order by the Seller shall not be deemed to be anacceptance of any terms of the Buyer by the Seller.

Unless otherwise provided for in these Standard Sales Terms,the relationship between the Seller and the Buyer shall begoverned by the provisions of applicable law.

If these Standard Sales Terms are otherwise inapplicable orineffective for any reason whatsoever, the sale of any goodsdelivered by the Seller to the Buyer (“the Goods”) shall besubject to the reservations of Clause 6 in Article V hereinbelow.

Article I General Terms

1. Any bid or offer submitted by the Seller to the Buyer shallnot be binding upon the Seller and unless otherwiseexpressly agreed upon by the Seller and the Buyer, nocontract placed by the Buyer shall be effective unlessexpressly accepted by the Seller in writing.

2. The title to any sample, drawing or other document orinformation, whether reduced to writing or in electronicform, including but not limited to any copyrights or otherrights associated therewith, which may be provided by theSeller to the Buyer shall remain vested in the Seller and nosuch sample, drawing or other document or informationmay be made accessible by the Buyer to any third party.

3. Any performance or other data or description of any Goodsby the Seller in any brochure, price list, bid, proposal, offeror any other document which may form part of any suchbid, proposal or offer shall be deemed to be approximate inaccordance with standard industry practices and shall not bebinding upon the Seller unless expressly accepted as bindingby the Seller and the Seller does not make any warrantieswhatsoever with respect to any properties of any of theGoods.

4. Commercial terms agreed between the Seller and the Buyershall be interpreted in accordance with Incoterms 2000.

Article II Price and Payment

1. Unless expressly otherwise agreed upon, any price agreedbetween the Seller and the Buyer shall be ex works exclusiveof any packaging. Each such price shall be exclusive of anysales tax which shall be billed by the Seller in addition tosaid price at the rate which may be applicable at any timeand from time to time.

2. Unless otherwise agreed upon, the price of any of the Goodsshall be paid without any deduction for any reasonwhatsoever as follows:- One third upon the receipt of the Seller’s acceptance of the

contract placed by the Buyer- One third upon the receipt by the Buyer of the Seller’s

notice that all main components of the Goods are ready forshipment

- The remaining sum upon the transfer of the risks of theGoods to the Buyer and upon the issuance of the Seller’sfinal invoice for the Goods

3. The Buyer shall not have the right to retain any paymentdue to the Seller for any reason whatsoever and shall notdeduct from any moneys due to the Seller any money owedor allegedly owed by the Seller to the Buyer unless any suchcounterclaim is undisputed by the Seller or has beenawarded to the Buyer by a judgment from which no appealcan be taken.

4. If, during the period between the date on which any contractwas awarded by the Buyer to or any order was placed by theBuyer with the Seller and the date on which production forthe performance of said contract or order commences, anylabor, material and/or production costs associated with saidcontract or order increase for any reason for which the Selleris not liable and the cost of any of the Goods (as defined inSection 255 of the German Commercial Code) as determinedin accordance with generally accepted German accountingprinciples is shown by the Seller to have risen by more thantwenty percent (20%) since the date of contract award ororder placement, then the Seller shall have the right toredetermine the price of any such Goods payable by theBuyer under said contract or order provided however thatthe Seller shall not be entitled to increase said price by morethan the increase in said cost.

5. The Buyer shall pay any amount owing to the Seller withinseven (7) calendar days from the due date for the paymentof said amount.

Article III Delivery Time and Late Delivery

1. The time available to the Seller for the delivery of the Goods(“Delivery Time”) shall be as agreed between the Parties inthe contract placed. The Seller shall not be obligated todeliver within said Delivery Time unless all technical andcommercial details have been agreed upon order placementand the Buyer performs all of its obligations under saidcontract or order such as, without limitation, any obligation

General Sales Terms and Conditionsof GEA Tuchenhagen GmbH

(Edition May 2003)

Page 123: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

123

GEA Tuchenhagen

to obtain necessary certificates, approvals or permits fromagencies or authorities and the obligation to make anyadvance payment provided that any non-satisfaction of anyof the preceding conditions shall operate to increase theDelivery Time reasonably and further provided that no delayfor which the Seller may be liable shall operate to increasethe Delivery Time.

2. The Seller shall not be obligated to deliver any Goods within the Delivery Time unless the Seller receives delive riesfrom its suppliers as and when ordered by the Sellerprovided that the Seller shall notify the Buyer as soon asreasonably possible of any delay in delivery it may becomeaware of.

3. The Seller shall be deemed to have delivered within theDelivery Time if the Goods have left the Seller’s works priorto the expiry of the Delivery Time or the Seller has notifiedthe Buyer prior to the expiry of the Delivery Time that theGoods are ready for Delivery.

4. If the Buyer fails to make any payment to the Seller underany contract or order whatsoever when said payment is due,the Seller shall, upon notice to the Buyer, have the right todiscontinue performance under the contract awarded or theorder placed for the Goods until the payment the Buyer hasfailed to make when due has been received providedhowever that the Seller shall not have said right if thepayment so due but not made is immaterial.

5. If the Seller is unable to deliver any Goods within theDelivery Time for reasons of force majeure, due to any labordispute or due to any circumstances beyond the reasonablecontrol of the Seller then the Delivery Time shall beextended reasonably. The Seller shall notify the Buyer of thecommencement and the end of any such circumstances assoon as may be reasonably possible.

Article IV Transfer of Risk and Acceptance

1. Unless expressly otherwise agreed upon between the Sellerand the Buyer, the Goods shall be delivered ex works.

2. If the Goods to be delivered by Seller to the Buyer aredivisible, then the Seller shall have the right to deliver andto invoice to the Buyer said Goods in reasonable parts andthe Buyer shall not have the right to retain payment for anysuch reasonable part on the grounds of the non-delivery ofany other parts of the Goods.

3. If any delivery by the Seller to the Buyer requires acceptanceby the Buyer under any express provision of the orderplaced by the Buyer or at law, then any delivery by the Sellerto the Buyer shall be deemed to have been accepted by theBuyer if and in as far as- any Goods manufactured or processed by the Seller are,

after delivery, sold to or allowed to be used by any thirdparty or

- any Goods manufactured or processed by the Seller are,

after delivery, processed or mixed or combined with anyother things with the agreement of the Buyer or

- any Goods manufactured or processed by the Seller are,beyond trials or tests, used by the Buyer or by any thirdparty with the agreement of the Buyer or

- the Goods are accepted by any purchaser from the Buyer whatever may be earlier provided that any prior acceptanceunder the contract awarded or the order placed by the Buyeror at law shall take precedence over any acceptance underthis Clause.

Article V Retention of Title

1. The title to all Goods delivered by the Seller to the Buyershall remain vested in the Seller until the full payment of allaccounts receivable by the Seller from the Buyer for anyreason whatsoever provided that under current accountarrangements the title so retained shall be deemed to besecurity for any balance owed to the Seller.

The Buyer shall not dispose of any of the Goods the title towhich is so vested in the Seller (“Title Reservation Goods”)other than in the Buyer’s ordinary course of businessprovided that the Buyer shall no longer have the right so todispose of any Title Reservation Goods if and as soon as theBuyer fails to make payments when payments are due. TheBuyer shall not have the right to pledge or to transfer byway of security the title to any Title Reservation Goods. TheBuyer shall be obligated to maintain the rights of the Sellerif the Title Reservation Goods are sold by the Buyer to anythird party under credit arrangements. The Buyer shallpromptly notify the Seller of any lien of attachment,execution or garnishment or any seizure or the like relatingto any Title Reservation Goods.

The Buyer hereby assigns to the Seller and the Seller herebyaccepts the Buyer’s assignment of any title to payment forany of the Goods resold by the Buyer to any purchaser andany security received by the Buyer from any such purchaserfor any such payment provided however that the Buyershall, subject to any notice to the contrary given by theSeller, have the right to collect any such payment and toenforce any such security at its cost. Upon the request of theSeller, the Buyer shall notify the Seller of the debtors againstwhich titles to payment so assigned are held, the securitiesprovided therefor, the type and the amount of the debt ofeach such debtor and the type and the amount of each suchsecurity and deliver to the Seller all documents which maybe necessary to collect any amount so owed by any suchdebtor. Upon notice to the Buyer, the Seller shall have theright to notify any such debtor of the assignment of the titleto payment by the Buyer to the Seller hereunder.

2. If the Goods are sold by the Buyer to any purchaser togetherwith any other goods the title to which is not vested in theSeller, then a share of the full title to payment of the Buyerunder said sale to said purchaser equal to the price of saidGoods agreed between the Buyer and the Seller shall bedeemed to have been assigned by the Buyer to the Seller.

General Sales Terms and Conditions of GEA Tuchenhagen GmbH (May 2003)

Page 124: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

124

GEA Tuchenhagen

3. Upon the request of the Buyer, the Seller shall waive anytitle to Goods delivered by the Seller to the Buyer in as far asthe value of all Goods the title to which has been retained bythe Seller hereunder exceeds one hundred ten percent(110%) of the value of all titles to payment the Seller holdsagainst the Buyer.

4. The Buyer shall, as of the transfer of risks associated withTitle Reservation Goods, insure all Title Reservation Goodsagainst any damage or loss or destruction as a result of anyfire, inundation, flooding or theft or any destruction or lossor damage in transit provided that the Buyer shall notify theSeller promptly of any such destruction or loss or damageand shall, upon the request of the Seller, provide to theSeller any documentation of any such loss or damage suchas, without limitation, any expert report on said destructionor loss or damage, the names of the insurers of said Goodsand, as requested by the Seller, the insurance policy orpolicies relating to the Title Reservation Goods or insurancecertificates issued by the insurer or the insurers for the TitleReservation Goods. The Buyer hereby assigns to the Seller,conditionally as of the time of any such destruction or lossof or damage to any Goods, any title against any insurer orany party liable for any such destruction or loss or damageto a maximum amount equal to the price agreed for anysuch Goods affected by any such destruction or loss ordamage by way of security for all moneys owed by theBuyer to the Seller.

5. Any processing of any Title Reservation Goods by the Buyershall be for the Seller and the Seller shall be deemed to bethe processor for the purposes of Section 950 of the GermanCivil Code. If Title Reservation Goods are processed,combined or mixed with other goods the title to which is notvested in the Seller, then a fraction of the title to the newproduct equal to the ratio between the price invoiced to theBuyer for the Goods so processed, combined or mixed andthe sum of the price invoiced to the Buyer for the Goods soprocessed, combined or mixed and the price or pricesinvoiced to the Buyer for the other goods so processed,combined or mixed shall be vested in the Seller. The Buyershall be the custodian of any such new product the title towhich is vested in the Seller in total or in part for the Seller.If any such Title Reservation Goods are processed, combinedor mixed with goods of the Buyer and the goods of theBuyer are the main constituents of the new product therebycreated, then the Buyer shall be deemed to have transferredto the Seller a fraction of the title to any such new productcomputed in accordance with the principles of the precedingsentence and shall be the custodian of said new product forthe Seller.

The provisions of Clauses 1 through 4 hereinaboveapplicable to Title Reservation Goods shall apply mutatismutandis to any new product obtained by processing,combination or mixing in which the Seller acquires in totalor in part a title through the operation of this Clause.

6. If these Standard Sales Terms have not been agreedeffectively, any transfer of title to any of the Goods shall be

subject to the Seller receiving the full price agreed betweenthe Seller and the Buyer therefor.

Article VI Defects

1. General

1.1 If Section 377 or Sections 377 and 381 of the GermanCommercial Code (sales and contract manufactureagreements between business organizations as defined inSection 1 et seq, of the German Commercial Code) areapplicable to the order placed, the Buyer shall notify theSeller promptly of any patent defect in any of the Goodsprovided that said notice shall be given no later than on thefourth (4th) working day following the delivery of saidGoods. Any latent defect in any of said Goods shall benotified promptly by the Buyer to the Seller provided thatsaid notice shall be given no later than on the fourth (4th)working day following the discovery of said defect. Eachsuch notice of any defect in any of the Goods shall be inwriting. The conditions applicable to any such notice andthe effects of a late notice of any defect in any of the Goodsshall furthermore be governed by the conditions of law(Sections 377, respectively 377 and 381 of the GermanCommercial Code),

1.2 If the Buyer is not a business organization, notice of anypatent defect in any of the Goods delivered by the Seller tothe Buyer shall be given by the Buyer to the Seller withintwo (2) weeks following the delivery of said Goods in thecase of sales and contract manufacture agreements andwithin two (2) weeks following acceptance in the case ofservice agreements. The term provided for hereinbefore shallbe deemed to have been complied with if said notice isforwarded by the Buyer within said term and received bythe Seller within four (4) weeks from such delivery oracceptance as the case may be. The Buyer shall not beentitled to any remedy for any patent defect in any of theGoods if the Buyer fails to give notice as aforesaid unlessand in as far as- the Seller is liable for said defect due to willful act, neglect

or omission, any act of bad faith or any gross negligence,- said defect is covered by a warranty of the Seller in

accordance with Section 443 of the German Civil Code or- said defect is claimed in connection with loss of human

life, injury, impairment of health or loss of freedomprovided that any liability of the Seller for any such defectshall be excluded in accordance with the provisions of lawsuch as but not limited to the provisions of Section 640,paragraph 2, or Section 442 of the German Civil Code if theBuyer had known said defect or did not know said defectdue to its own gross negligence.

2. Product Defects

2.1 If any of the Goods delivered by the Seller to the Buyer isdefective, the Seller shall remedy said defect by repair orreplacement. If said remedial action fails, then, subject to theprovisions on damages in Article VII hereinbelow, the Buyer

General Sales Terms and Conditions of GEA Tuchenhagen GmbH (May 2003)

Page 125: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

125

GEA Tuchenhagen

shall be entitled to any of the remedies provided for by law.

2.2 If any remedial action is taken by the Seller, then the Sellershall bear all costs and expenses occasioned by the removalof said defect such as, without limitation, any transportationor traveling expenses or any labor or material costs providedhowever that any extra costs occasioned by the Buyermoving the Goods after delivery to a place other than theregistered premises of the Buyer shall be carried by theBuyer unless the removal of said Goods is a use for whichthe Goods are intended.

2.3 The Buyer shall give the Seller the time and the opportunitywhich may be needed to remove any defect in any of theGoods provided that the Seller shall not be held liable forany consequences of not being given such time andopportunity.

2.4 Any repair or replacement by the Seller with respect to anyGoods shall irrespective of the scope of any such repair orreplacement not be deemed to be an acceptance of anyliability for any defect in any of the Goods claimed by theBuyer provided that no persons other than legalrepresentatives or procurators under Sect. 49 GermanCommercial Code (“Prokuristen”) of the Seller shall have theright to accept any liability for any defect on behalf of theSeller.

2.5 If any defect in any of the Goods claimed by the Buyershows not to be a defect for which the Seller is liable, thenthe Buyer shall reimburse to the Seller all costs reasonablyincurred by the Seller to remove said alleged defect in goodfaith provided that material and labor costs so incurred bythe Seller shall be reimbursed at the Seller’s standard ratesapplicable at the time when the alleged defect was soremoved.

2.6 The Buyer shall not be entitled to the removal by the Sellerof any defect due to any of the following:- Improper use of any Goods or use of any Goods for a

purpose for which the Goods are not fit or defectiveinstallation or commissioning of the Goods by the Buyer orany third party

- Natural wear and tear, improper or negligent handling,improper maintenance or use of any unfit consumables orutilities

- Defective construction work, unsuitable foundations orchemical, electrochemical or electrical interference unlesscaused by the Seller

2.7 The Seller shall not be held liable for the consequences ofany improper or inappropriate removal of any defect in anyof the Goods by the Buyer or any third party or anymodification to any of the Goods made without the Seller’sprior consent.

3. Legal Defects

3.1 The liability of the Seller for the Goods not to be in breachof any third-party industrial property rights or copyrightsshall be limited to the Federal Republic of Germany and thecountry in which the Buyer is registered. The Seller shallhave no such liability for any other country, such as anycountry to which the Goods may be moved by the Buyer,unless such other country has been notified by the Buyer tothe Seller prior to awarding the contract or placing the orderfor the Goods.

3.2 If the use of the Goods delivered by the Seller to the Buyer isin breach of any third-party industrial property rights orcopyrights and the Seller is liable for said breach accordingto Clause 3.1 hereinabove, the Seller shall, at its cost, obtainfor the Buyer the right to continue the use of said Goods ormodify said Goods in a manner reasonably acceptable to theBuyer so that said Goods will no longer be in breach of anysuch industrial property rights or copyrights. If such rightscannot be obtained at reasonable commercial terms orwithin a reasonable period of time and if the Goods cannotbe so modified, then the Buyer shall have the right, at itsdiscretion, to rescind the contract awarded by the Buyer tothe Seller or the order placed by the Buyer with the Seller orto obtain from the Seller a reasonable reduction in the priceof said Goods.

The Seller shall in any such event further indemnify theBuyer against any undisputed claims or any claimsdetermined by non-appealable court decision of the ownersof such industrial property rights or copyrights.

3.3 Subject to Clause 3.4 hereinbelow, the Buyer shall not havethe rights under Clause 3.2 hereinabove, unless- the Buyer notifies the Seller promptly of any breach of

industrial property rights or copyrights claimed by anythird party,

- the Buyer reasonably supports the defense of any suchclaims by the Seller and allows the Seller to makemodifications as referred to in Clause 3.2 hereinabove,

- the Buyer allows the Seller to defend at its own cost anysuch claim or to make any out-of-court settlement withrespect to any such claim as the Seller may think fit,

- the legal defect is not due to any instructions given by theBuyer to the Seller and

- the legal defect is not due to any modification of the Goodsby the Buyer or any use of the Goods not in conformitywith the intended use.

3.4 Notwithstanding the limitations in Clauses 3.2 and 3.3 hereinabove, the provisions laid down by law shall apply, ifand in as far as- the title of the Buyer against the Seller is held under Section

478 or under Sections 651 and 478 of the German Civil Code,- the Seller is liable for the breach of the industrial property

rights or the copyrights due to any willful act, neglect oromission or any gross negligence on the part of the Seller,

- the Seller warranted (as provided for in Section 443 of the

General Sales Terms and Conditions of GEA Tuchenhagen GmbH (May 2003)

Page 126: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

126

GEA Tuchenhagen

German Civil Code) that the Goods will not violate anyindustrial property rights or copyrights or

- any damages claimed as a result of any breach of anyindustrial property rights or copyrights are on the groundsof any loss of life, injury, loss of health or loss of freedom.

4. Warranties Under Section 443 of the German Civil Code

No person other than a legal representative or a procuratorunder Sect. 49 German Commercial Code (“Prokuristen”) ofthe Seller will have the right to agree any warrantiesaccording to Section 443 of the German Civil Code.

Article VII Liability and Damages

1. The Seller shall be liable for any willful acts, neglects andomissions and any gross negligence of its legalrepresentatives and/or any other persons authorized by theSeller to perform any of the obligations of the Seller underany contract awarded to the Seller or order placed with theSeller (“Agent or Employee”).

2. In the event of any ordinary negligence of any legalrepresentative, Agent or Employee of the Seller, the liabilityof the Seller shall be limited to liability for any loss ordamage the Seller foresaw when the contract was awardedor the order was placed by the Buyer or should haveforeseen when the contract was awarded or the order wasplaced by the Buyer considering the circumstances the Sellerknew or should have known when the contract was awardedor the order was placed by the Buyer.

If and in as far as any loss or damage suffered by the Buyerdue to the ordinary negligence of any legal representative,Agent or Employee of the Seller is compensated by any finalpayment by any insurer under any insurance contractagainst loss or indemnity concluded by the Buyer or for theBuyer such as, but not limited to any liability, all-risks,transportation, fire or business interruption insurance, theliability of the Seller shall be limited to any losses incurredby the Buyer as a result of any such insurance claim such as,without limitation, any increase in insurance premium. Anyliability of the Seller for any loss or damage caused by theordinary negligence of any of the legal representatives,Agents or Employees of the Seller and covered by a finalinsurance payment to the Buyer shall be excluded.

Subject to the limitations provided for hereinbefore, anyliability of the Seller for any loss or damage caused by theordinary negligence of any legal representative, Agent orEmployee of the Seller shall for each incident be limited toan amount of two hundred fifty thousand Euros (250,000 1).

3. The exclusions and limitations of liability provided for hereinabove shall not apply,- if and in as far as the Seller is held liable for any human

loss of life, injury or loss of health,- if and in as far as the Seller is held liable under the

German Product Liability Act or- if and in as far as the Seller is held liable under any

warranty in accordance with Section 443 of the GermanCivil Code agreed by the Seller to provide security to theBuyer with respect to the loss or damage incurred by theBuyer.

4. The provisions of Clauses 1 through 3 hereinabove shall notoperate to alter any of the provisions of law regarding theonus probandi.

Article VIII Limitation

1. The period of limitation with respect to any defect shall be aperiod of one (1) year provided that said period shall be five(5) years for any defect in any Goods serving as civilengineering structure or structures or any defect in any civilengineering structure caused by any Goods ordinarily usedin civil engineering structures.

2. The period of limitation with respect to any other causeunder the contract awarded or the order placed by the Buyeror any other cause outside said contract or order shall be aperiod of eighteen (18) months.

3. Notwithstanding the provisions of Clauses 1 and 2 herein -above, the periods of limitation allowed by law shall apply,if and in as far as- the title held by the Buyer against the Seller is under

Section 478 or Sections 651 and 478 of the German CivilCode,

- the title of the Buyer is held on the grounds of any willfulact, neglect or omission, any act of bad faith or any grossnegligence on the part of any of the legal representatives,Agents or Employees of the Seller,

- the title held by the Buyer against the Seller is on thegrounds of any loss of life, injury, loss of health or loss offreedom of any person,

- the title held by the Buyer against the Seller is under theGerman Product Liability Act,

- the title held is on the grounds of a third party title in remwhich grants any such third party a title to the surrenderof the Goods (Sect. 438 para.1 subsubpara. a German CivilCode) or

- the title held is on the grounds of any title recorded in anyregister of deeds (Sect. 438 para.1 subpara. b German Civil Code).

The provisions in Clauses 1 and 2 shall further not apply ifthe title is held by the Buyer under a warranty of the Sellerin accordance with Section 443 of the German Civil Codeprovided that any such title shall exclusively be subject tothe provisions of Clause 4 hereinbelow.

4. The period of limitation applicable to any warranty of theSeller in accordance with Section 443 of the German CivilCode shall commence upon the delivery of the Goods to theBuyer or, if acceptance by the Buyer is required by law,upon the acceptance of the Goods by the Buyer providedthat, in the event of bad faith, said period shall commence asprovided for in Section 438, paragraph 3, of the German

General Sales Terms and Conditions of GEA Tuchenhagen GmbH (May 2003)

Page 127: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

127

GEA Tuchenhagen

General Sales Terms and Conditions of GEA Tuchenhagen GmbH (May 2003)

Civil Code. Said period shall terminate as provided for inSection 438 of the German Civil Code unless a shorterperiod has been agreed according to the terms of thewarranty under Section 443 of the German Civil Code.

5. Clauses 1 through 4 hereinabove shall not operate to alterany of the provisions of Sections 196, 197 and 479 of theGerman Civil Code or any of the provisions of law applicableto the onus probandi.

Article IX Software Use

If the contract awarded by the Buyer to the Seller or the orderplaced by the Buyer with the Seller provides for the supply ofsoftware, the Buyer will be granted a non-exclusive right to usesaid software and any documentation of said software. Saidsoftware will be supplied by the Seller to the Buyer for use withthe Goods delivered by the Seller to the Buyer provided that theBuyer shall not have the right to use said software on more thanone system.

Any copying, modification or translation of said software or anyconversion of the object code of said software into source codeshall be limited as provided for in Section 69 et seq. of theGerman Copyright Act. The Buyer agrees not to remove fromsaid software any reference to the developer of said softwaresuch as, without limitation, any copyright reference and not tomodify any such reference unless the prior express content ofthe Seller has been obtained.

Any other rights associated with such software and anydocumentation of said software and any copies thereof shallremain vested in the Seller or the supplier of said software asthe case may be. The Buyer shall not grant any sub-license.

Article X Applicable Law and Jurisdiction

1. The relationship between the Seller and the Buyer shallexclusively be governed by the law of the Federal Republicof Germany as the same may be applicable to therelationship between two German parties provided howeverthat the application of the United Nations Convention onContracts for the International Sale of Goods of 11 April 1980shall be excluded.

2. If the Buyer is a business or any public-law legal person orother entity, any dispute between the Seller and the Buyershall be settled by the courts having jurisdiction at theregistered offices of the Seller provided however that theSeller shall have the right to bring action against the Buyerin the courts having jurisdiction at the registered offices ofthe Buyer.

3. If any of the terms and conditions of the Contract or theseStandard Sales Terms is or become ineffective, theremaining provisions of the Contract and these StandardSales Terms shall remain in full force and effect. Any suchineffective provision shall be deemed to have been replacedby the Seller and the Buyer by an effective provision which

shall have commercial, financial and economic implicationswhich shall be as close to those of said ineffective provisionas may be reasonably.

Page 128: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

Notes

Page 129: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

129

GEA Tuchenhagen

Page 130: Catalog hygienic centrifugal pumps 2015 03 en tcm11 13267

GEA

Tuc

henh

agen

-Pum

ps 0

7/20

14

GEA Mechanical Equipment

GEA Tuchenhagen GmbH

Am Industriepark 2-10, 21514 Büchen, GermanyPhone +49-4155 [email protected], www.gea.com

GEA Group is a global engineering company with multi-billion euro sales and operations in more than

50 countries. Founded in 1881, the company is one of the largest providers of innovative equipment and

process technology. GEA Group is listed in the STOXX® Europe 600 Index.

We live our values.Excellence • Passion • Integrity • Responsibility • GEA-versity