catalogo moller
TRANSCRIPT
Moeller HPL0211-2001/2002
Control Circuit Devices Overview
Cont
rol C
ircu
it D
evic
es
02/002
RMQ Titan®
Grid dimensions: 30 x 40/30 x 50 mmMounting diameter: 22.3 mm
PageSystem overview 02/004
Complete units for front mounting 02/006
Complete units for surface mounting 02/007
Emergency-Stop actuators 02/011
Complete units for surface mounting
02/011
Complete units for flush mounting 02/011
Emergency-Stop actuators 02/011
Push-button actuators 02/013
Double actuators 02/010
Mushroom actuators 02/015
Selector switch actuators 02/017
Two positions 02/017
Three positions 02/017
Key-operated actuators 02/018
Two positions 02/018
Three positions 02/018
For master key systems 02/019
Illuminated push-button actuators 02/021
Flush 02/021
Extended 02/022
Key to RMQ Titan type referencese.g. illuminated selector switch actuator M22S-WLK-W
4th groupColour of actuator (lens)
B BlueG GreenR RedS BlackY YellowW WhiteX Without button plateMS1-20 Individual lock
mechanism SA(...) Master key systemGVP Bulk pack
3rd groupAdd-on functions
R Stay-putL IlluminatedG Protected actuatorH ExtendedK Thumb-gripP MushroomS LockV V position3 3 switch positions
2nd groupBasic functions
D Push-buttonDD Double push-buttonL Indicator lightLC Compact indicator lightPV Emergency-StopW Selector switchAM Acoustic indicator
1st group
M Moeller22 22 mm o S Black
PageIlluminated selector switch actuators 02/023
Two positions 02/023
Three positions 02/023
Indicator light lens assemblies 02/020
Acoustic indicator 02/020
Contact elements 02/024
With screw terminals 02/024
With Cage Clamp 02/024
LED elements 02/025
With screw terminals 02/025
With Cage Clamp 02/026
Accessories 02/038
Marking plates 02/027
Button plates 02/028
Flush mounting panels, shrouds 02/036
Surface mounting enclosures 02/037
Compact indicator lights 02/039
Technical data 02/068
Dimensions 02/073
Cont
rol C
ircu
it D
evic
es
02/003Moeller HPL0211-2001/2002
Control Circuit Devices Overview
RMQ16Grid dimensions: 18 x 18 mm/25 x 25 mmMounting diameter: 16.2 mm
PageSystem overview 02/042
Push-button actuators 02/044
Spring-return 02/044
Stay-put 02/044
Illuminated push-button actuators 02/045
Spring-return 02/045
Stay-put 02/045
Selector switch actuators 02/046
Two positions 02/046
Three positions 02/047
Key-operated actuators 02/046
Two positions 02/046
Three positions 02/047
Illuminated selector switch actuators 02/048
Two positions 02/048
Three positions 02/048
Indicator lights 02/050
Flush 02/050
Conical 02/050
Emergency-Stop 02/051
Emergency-Stop actuators 02/051
Emergency-Stop labels 02/051
Contact elements 02/044
Break contacts 02/044
Make contacts 02/044
Accessories 02/059
Marking plates 02/052
Flush mounting panels 02/058
Surface mounting enclosures 02/058
Technical data 02/070
Dimensions 02/078
SL ... signal towers
PageSystem overview 02/062
Complete units 02/064
Modules 02/066
Accessories 02/067
Technical data 02/072
Dimensions 02/081
Moeller HPL0211-2001/2002
RMQ TitanSystem Overview
Cont
rol C
ircu
it D
evic
es
02/004
1
2
4
5
6
4
4
3
3
13
12
10
11
9
14
8
4
4
7
Cont
rol C
ircu
it D
evic
es
02/005Moeller HPL0211-2001/2002
RMQ TitanSystem Overview
Emergency-Stop actuators 1Tamper proof to ISO 13 850/EN 418
Can be secured by means of sealable shroud
Additional plates with and without text
German Trade Association approval applied fora Page 02/011
Label mounts 2For insert platesColour: blackAluminium-coloured insert plates, with and without text, can be engraved
a Page 02/027
Fixing adapter 3For front fixingFor contact and LED elements
a Page 02/024
Contact elements 4Break contacts and make contactsUniversal contacts suitable for use with electronic devicesPositive opening safety function toIEC/EN 60 947-5 -1
a Page 02/024
LED elements 4Voltage range: 18 – 30 V AC/DC85 – 264 V AC
a Page 02/025
Enclosures 5Surface mounting enclosures IP66 up to 6 locations
Flush mounting panels IP54 up to 6 locationsShrouds IP40 for flush mounting panels
a Page 02/036
Telescopic clip 6For adjusting the depth of rear mounting devices in CI enclosures, CI-K4 enclosures and panels
a Page 02/038
Centring adapter 7For centring actuators and indicators when using telescopic clip
a Page 02/038
IVS top-hat rail adapter 8For direct mounting onto top-hat railto EN 50 022
a Page 02/038
Indicator lights 9Flush and conical versionsColours: white, green, red, yellow, blue
a Page 02/020
Key-operated actuators 10Two or three positionsProgrammable spring-return/stay-put function and key withdrawalSuitable for master key systems
a Page 02/018
Selector switch actuators 11Two or three positionsWith rotary head, thumb-gripProgrammable spring-return/stay-put function
Illuminated selector switch actuators with transparent thumb-gripColours: white, green, red, yellow, blue
a Page 02/017
Button plates/button lenses 12Inscription using laser technology for push-button actuators and mushroom actuatorsButton lenses for illuminated push-button actuators and indicator lights, flushWith standard texts and symbols or non-standard inscription
a Page 02/028
Push-button actuators 13Spring-return and stay-putFlush and extendedWith and without guard ringMushroom actuatorsDouble actuatorsColours: white, green, red, yellow, blue, blackIlluminated push-button actuators Colours: white, green, red, yellow, blue
a Page 02/013
Acoustic indicator 14Degree of protection IP40, continuous tone, 18 – 30 V DC
a Page 02/020
Product features• Snap-fitting modular system • Mounting diameter: 22.3 mm • Up to 6 contacts per location• Front ring titanium or black • Minimum grid dimension 30 x 40 mm • Switching of different potentials
• Degree of protection IP66 • Approved throughout the world
Moeller HPL0211-2001/2002
RMQ TitanComplete Units for Front Mounting
Cont
rol C
ircu
it D
evic
es
02/006
-Front ring titanium
Button plate Contacts1)
M = Make, B = Break,f = Positive opening safety function to IEC/EN 60 947-5-1
Type PriceArticle no. See Price
ListStd.pack
Push-buttons, IP67, IP69KActuator flush 1 M – M22-D-G-X1/K10
2165125 off
– 1 B f M22-D-R-X0/K01216510
1 M 1 B f M22-D-G-X1/K11216513
1 M 1 B f M22-D-R-X0/K11216511
Double push-buttons, IP66Cover plate black 1 M – M22-DD-GR-X1/X0/K11
2165065 off
– 1 B f
With LED elementlens white 85 – 264 V AC
1 M – M22-DDL-GR-X1/X0/K11/230-W216509
5 off
– 1 B f
Selector switches, black thumb-grip, IP66
Stay-put/spring-return function can be changed using M22-XC-Y coding adaptersTwo positions, stay-put 1 M – M22-WRK/K10
2165185 off
1 M 1 B f M22-WRK/K11216519
Three positions, stay-put 2 M – M22-WRK3/K20216520
Key-operated button, with 1 key, IP66
Stay-put/spring-return function and key withdrawability can be changed using M22-XC-... coding adaptersTwo positions, stay-putMS1 lock mechanism
1 M 1 B f M22-WRS/K11216517
5 off
Notes 1) Special versions can be supplied as complete units for orders of 50 or more. Switch positions 0, I, II correspond to the position of the actuating element viewed from the front.
13
14
21
22
21
22
13
14
13
14
21
22
13
14
21
22
13
14
0
13
14
0 21
22
13
14
0 23
24
0
13
14
21
22
Cont
rol C
ircu
it D
evic
es
02/007Moeller HPL0211-2001/2002
RMQ TitanComplete Units for Surface Mounting, IP66
Front ring titanium
Number of locations
Contacts1)
M = Make, B = Break,f= Positive opening safety function to IEC/EN 60 947-5-1
Colour2)
enclosure top
Type PriceArticle no. See Price
ListStd.pack
Push-buttonsActuator flush 1 1 M 1 B f M22-D-G-X1/KC11/I
2165221 off
1 1 M 1 B f M22-D-R-X0/KC11/I216521
1 off
Emergency-Stop key-release mushroom button2)
With 1 keyMS1 lock mechanism 1 1 M 1 B f M22-PVS/KC11/IY
2165231 off
Key-operated buttons
Stay-put/spring-return function and key withdrawability can be changed using M22-XC-... coding adaptersWith 1 key
2 positions, stay-put MS1 lock mechanism
1 1 M 1 B f M22-WRS/KC11/I216526
1 off
Enclosures
With contact elementsWithout actuator 1 1 M 1 B f M22-I1-M1
2165271 off
1 1 M 1 B f M22-I1Y-M1216528
1 off
Two-way push-button station2 2 M 2 B f M22-I2-M1
2165292 off
Two-way push-button station
With indicator lightLED element85 – 264 V AC
2 2 M 2 B f M22-I3-M2216533
1 off
Three-way push-button station3 3 M 3 B f M22-I3-M1
2165321 off
Four-way push-button station4 4 M 4 B f M22-I4-M1
2165341 off
Notes 1) Special versions can be supplied as complete units for orders of 50 or more. Switch positions 0, I, II correspond to the position of the actuating element viewed from the front.
2) Grey = RAL 7035Yellow = RAL 1004
14 13
22 21
14 13
22 21
14 13
22 21
2221
1413
2221
1413
2221
1413
2221
1413
2221
1413
2221
1413
2221
1413
2221
1413
2221
1413
2221
1413
2221
1413
2221
1413
2221
1413
Moeller HPL0211-2001/2002
RMQ TitanComplete Units for Surface Mounting
Cont
rol C
ircu
it D
evic
es
02/008
ContactsM = Make, B = Break,f = Positive opening safety function to IEC/EN 60 947-5-1
Colour of mushroom head, indicator light
Type PriceArticle no. See Price
ListStd. pack
Foot and palm switches, IP67, 69K
Enclosure base, black (RAL 9005)Enclosure top, light grey (RAL 7035)
Spring-return 1 M – FAK-SW/KC10/I030722
1 off
1 M 1 Bf FAK-SW/KC11/I030723
– 2 B f FAK-RT/KC02/I030724
1 M 1 Bf FAK-RT/KC11/I032965
1 M 2 B f FAK-RT/KC12/I030725
1 M 1 Bf FAK-GE/KC11/I032710
Stay-putPull to release
1 M 1 Bf FAK-GE/V/KC11/I032706
Indicator lights, conical, BA 9s
For filament bulbs, neon bulbs and LEDs up to 2.4 Wa Page 02/040
L-R208689
1 off
L-W208692L-G208690L-Y208691
PG 13.5 cable gland, IP68, 69K
With integral strain relief to VDE 0619External cable diameter 6 – 12 mm
STBZ13,5036307
1 off
14 13
14 13
22 21
22 21
12 11
14 13
22 21
14 13
22 21
32 31
14 13
22 21
14 13
22 21
Cont
rol C
ircu
it D
evic
es
02/009Moeller HPL0211-2001/2002
RMQ TitanComplete Units for Surface Mounting
ContactsM = Make, B = Break,f = Positive opening safety function to IEC/EN 60 947-5-1
Colour of plunger1)
Type PriceArticle no. See Price
ListStd.pack
Foot and palm switches2), IP67, 69K
Emergency-Stop push-buttons, tamper proof to ISO 13 850/EN 418Enclosure base, black (RAL 9005)Enclosure top, yellow (RAL 1004)Pull to release
– 1 Bf FAK-RT/V/KC01/l030718
1 off
1 M 1 Bf FAK-RT/V/KC11/l030719
– 2 B f FAK-RT/V/KC02/l030720
1 M 2 B f FAK-RT/V/KC12/l030721
Notes 1) Red = RAL 30002) Indicator lights and cable gland for FAK, a Page 02/008
22 21
14 13
22 21
12 11
22 21
32 31
14 13
22 21
Moeller HPL0211-2001/2002
RMQ TitanDouble actuators
Cont
rol C
ircu
it D
evic
es
02/010
Front ring titanium Front ring black
Button platestyle
Type Type PriceArticle no. Article no. See Price
ListStd.pack
Double actuators, IP66Without indicator lightCover plate black
M22-DD-GR-X1/X0216685
M22S-DD-GR-X1/X0216686
5 off
M22-DD-WS-X1/X0216691
M22S-DD-WS-X1/X0216692
M22-DD-GR-GB1/GB0216687
M22S-DD-GR-GB1/GB0216688
M22-DD-WS-GB1/GB0216693
M22S-DD-WS-GB1/GB0216694
M22-DD-S-X7/X7216695
M22S-DD-S-X7/X7216696
M22-DD-S-X4/X5218143
M22S-DD-S-X4/X5218144
M22-DD-GR216683
M22S-DD-GR216684
M22-DD-WS216689
M22S-DD-WS216690
With indicator lightLens white
M22-DDL-GR-X1/X0216700
M22S-DDL-GR-X1/X0216701
5 off
M22-DDL-WS-X1/X0216706
M22S-DDL-WS-X1/X0216707
M22-DDL-GR-GB1/GB0216702
M22S-DDL-GR-GB1/GB0216703
M22-DDL-WS-GB1/GB0216708
M22S-DDL-WS-GB1/GB0216709
M22-DDL-S-X7/X7216710
M22S-DDL-S-X7/X7216711
M22-DDL-S-X4/X5218145
M22S-DDL-S-X4/X5218146
M22-DDL-GR216698
M22S-DDL-GR216699
M22-DDL-WS216704
M22S-DDL-WS216705
Cont
rol C
ircu
it D
evic
es
02/011Moeller HPL0211-2001/2002
RMQ TitanEmergency-Stop Buttons and Actuators
ContactsM = Make, B = Break,f = Positive opening safety function to IEC/EN 60 947-5-1
ColourColour of baseyellow
Type PriceArticle no. See Price
ListStd.pack
Plunger1)
Complete units for surface mounting, IP66, 69K
Emergency-Stop push-buttons, tamper proof to ISO 13 850/EN 418Pull to releaseMax. number of buttons to be fitted together: 3 x M22-(C)K...
1 M 1 B M22-PV/KC11/IY216525
1 off
– 2 B M22-PV/KC02/IY216524
1 off
Complete units for front mounting, IP66
Emergency-Stop push-buttons, tamper proof to ISO 13 850/EN 418Pull to releaseMax. number of buttons to be fitted together: 4 x M22-(C)K...
– 1 B f M22-PV/K01216515
5 off
1 M 1 B f M22-PV/K11216516
5 off
Emergency-Stop actuator – – – M22-PV
2168765 off
– – – M22-PV-GVP216877
50 off
Emergency-Stop actuator – – – M22S-PV225528
1 off
Emergency-Stop actuator Illuminated – – – M22-PVL
2168785 off
Emergency-Stop key-operated actuators, IP66With one key MS1 individual lock mechanisms – – – M22-PVS
2168795 off
MS2 – 20 individual lock mechanisms – – – M22-PVS-MS*216880
1 off
Emergency-Stop key-release mushroom button to ISO 13 850/EN 418With 1 key,MS1 individual lock mechanism
– 1 B f M22-PVS/K01216514
5 off
Notes 1) Red = RAL 3000
14 13
22 21
12 11
22 21
21
22
21
22
13
14
21
22
Moeller HPL0211-2001/2002
RMQ TitanEmergency-Stop Labels, Sealable Shroud
Cont
rol C
ircu
it D
evic
es
02/012
Text Country identifier(as explanation)
Colour Type PriceArticle no. See Price
ListStd.pack
Emergency-Stop labels, IP66
Black text,33 X 50 mm
Not-Aus D M22-XZK-D99216471
10 off
Emergency-Stop GB M22-XZK-GB99216472
Arrêt d'urgence F M22-XZK-F99216473
EMERGENZA I M22-XZK-I99216474
NOODSTOP NL M22-XZK-NL99216475
NÖDSTOPP S M22-XZK-S99216476
HÄTÄ-SEIS SF M22-XZK-SF99216477
NØDSTOP DK M22-XZK-DK99216478
Blank – M22-XZK216470
25 off
With customizedinscription1)
M22-XZK-*216479
10 off
50 x 50 mm Four-language D, GB, F, I M22-XYK1216484
10 off
o = 90 mm Blank M22-XAK216464
10 off
Four-language D, GB, F, I M22-XAK1216465
Four-language D, GB, E, POR M22-XAK2216466
Four-language D, GB, NL, F M22-XAK3216467
Four-language GB, S, SF, DK M22-XAK4216468
With customizedinscription
M22-XAK-*216469
o = 60 mm Four-language D, GB, F, I M22-XBK1216483
Sealable shroud2), IP66M22-PL-PV216397
2 off
Notes 1) Letter height: 5 mmNumber of lines: max. 2Characters per line: max. 7
2) Transparent with collapse point, can be reused after an Emergency-Stop. For use with M22(S)-PV, M22-PVL, M22-PVSAdjacent holes in the 30 x 50 mm grid, are to be sealed with M22(S)-B blanking plugs.
77
Cont
rol C
ircu
it D
evic
es
02/013Moeller HPL0211-2001/2002
RMQ TitanPush-Button Actuators
Front ring titanium Front ring black
Button platestyle
Type Type PriceArticle no. Article no. See Price
ListStd.pack
Push-button actuators, IP67, 69KActuator flush, spring-return
M22-D-S216590
M22S-D-S216591
10 off
M22-D-W216592
M22S-D-W216593
M22-D-R216594
M22S-D-R216595
M22-D-G216596
M22S-D-G216597
M22-D-Y216598
M22S-D-Y216599
M22-D-B216600
M22S-D-B216601
Without M22-D-X216602
M22S-D-X216604
Without M22-D-X-GVP216603
– 50 off
M22-D-R-X0216605
M22S-D-R-X0216606
10 off
M22-D-G-X1216607
M22S-D-G-X1216608
M22-D-S-X0216609
M22S-D-S-X0216610
M22-D-W-X1216611
M22S-D-W-X1216612
Actuator flush, stay-put
Programmable stay-put/spring-return function
M22-DR-S216613
M22S-DR-S216614
5 off
M22-DR-W216615
M22S-DR-W216616
M22-DR-R216617
M22S-DR-R216618
M22-DR-G216619
M22S-DR-G216620
M22-DR-Y216621
M22S-DR-Y216622
M22-DR-B216623
M22S-DR-B216624
Without M22-DR-X216625
M22S-DR-X216627
Without M22-DR-X-GVP216626
– 50 off
M22-DR-R-X0216628
M22-DR-R-X0216629
5 off
M22-DR-G-X1216630
M22S-DR-G-X1216631
M22-DR-S-X0216632
M22S-DR-S-X0216633
M22-DR-W-X1216634
M22S-DR-W-X1216635
Moeller HPL0211-2001/2002
RMQ TitanPush-Button Actuators
Cont
rol C
ircu
it D
evic
es
02/014
Front ring titanium Front ring black
Button platestyle
Type Type PriceArticle no. Article no. See Price
ListStd.pack
Push-button actuators, IP67, 69KActuator extended, spring-return
M22-DH-S216636
M22S-DH-S216637
5 off
M22-DH-W216638
M22S-DH-W216639
M22-DH-R216641
M22S-DH-R216642
M22-DH-G216643
M22S-DH-G216645
M22-DH-Y216646
M22S-DH-Y216647
M22-DH-B216649
M22S-DH-B216650
M22-DH-R-X0216655
M22S-DH-R-X0216656
5 off
M22-DH-G-X1216657
M22S-DH-G-X1216658
M22-DH-S-X0216659
M22S-DH-S-X0216660
M22-DH-W-X1216661
M22S-DH-W-X1216662
Actuator extended, stay-put
Programmable stay-put/spring-return function
M22-DRH-S216663
M22S-DRH-S216664
5 off
M22-DRH-W216665
M22S-DRH-W216666
M22-DRH-R216667
M22S-DRH-R216668
M22-DRH-G216669
M22S-DRH-G216670
M22-DRH-Y216671
M22S-DRH-Y216672
M22-DRH-B216673
M22S-DRH-B216674
M22-DRH-R-X0216675
M22S-DRH-R-X0216676
5 off
M22-DRH-G-X1216677
M22S-DRH-G-X1216678
M22-DRH-S-X0216679
M22S-DRH-S-X0216680
M22-DRH-W-X1216681
M22S-DRH-W-X1216682
With guard ring, spring-return
Without M22-DG-X220921
–
Cont
rol C
ircu
it D
evic
es
02/015Moeller HPL0211-2001/2002
RMQ TitanMushroom Actuators
Front ring titanium Front ring black
Button platestyle
Plungercolour
Type Type PriceArticle no. Article no. See Price
ListStd.pack
Mushroom actuators, IP67, 69KSpring-return M22-DP-S
216712M22S-DP-S216713
5 off
M22-DP-R216714
M22S-DP-R216715
M22-DP-G216716
M22S-DP-G216717
M22-DP-Y216718
M22S-DP-Y216719
M22-DP-R-X0216720
M22S-DP-R-X0216721
5 off
M22-DP-G-X1216722
M22S-DP-G-X1216723
M22-DP-S-X0216724
M22S-DP-S-X0216725
M22-DP-W-X1216726
M22S-DP-W-X1216727
Without M22-DP-S-X216728
M22S-DP-S-X216730
5 off
Without M22-DP-R-X216731
M22S-DP-R-X216733
Without M22-DP-G-X216734
M22S-DP-G-X216736
Without M22-DP-Y-X216737
M22S-DP-Y-X216739
Without M22-DP-S-X-GVP216729
– 25 off
Without M22-DP-R-X-GVP216732
–
Without M22-DP-G-X-GVP216735
–
Without M22-DP-Y-X-GVP216738
–
Moeller HPL0211-2001/2002
RMQ TitanMushroom Actuators
Cont
rol C
ircu
it D
evic
es
02/016
Front ring titanium Front ring black
Button platestyle
Plungercolour
Type Type PriceArticle no. Article no. See Price
ListStd.pack
Mushroom actuators, IP67, 69KStay-put
Programmable stay-put/spring-return function
M22-DRP-S216743
M22S-DRP-S216744
5 off
M22-DRP-R216745
M22S-DRP-R216746
M22-DRP-G216747
M22S-DRP-G216748
M22-DRP-Y216749
M22S-DRP-Y216750
M22-DRP-R-X0216751
M22S-DRP-R-X0216752
5 off
M22-DRP-G-X1216753
M22S-DRP-G-X1216754
M22-DRP-S-X0216755
M22S-DRP-S-X0216756
M22-DRP-W-X1216757
M22S-DRP-W-X1216758
Without M22-DRP-S-X216759
M22S-DRP-S-X216761
5 off
Without M22-DRP-R-X216762
M22S-DRP-R-X216764
Without M22-DRP-G-X216765
M22S-DRP-G-X216767
Without M22-DRP-Y-X216768
M22S-DRP-Y-X216770
Without M22-DRP-S-X-GVP216760
– 25 off
Without M22-DRP-R-X-GVP216763
–
Without M22-DRP-G-X-GVP216766
–
Without M22-DRP-Y-X-GVP216769
–
Cont
rol C
ircu
it D
evic
es
02/017Moeller HPL0211-2001/2002
RMQ TitanSelector Switch Actuators
Front ring titanium Front ring black
Function Text Type Type PriceV = Stay-put Article no. Article no. See Price
ListStd.packv = Spring-return
Selector switch actuators, two positions, IP66Rotary button v 40° M22-W
216853M22S-W216854
5 off
V 60° M22-WR216855
M22S-WR216856
V 60° M22-WR-X92216857
M22S-WR-X92216858
V 60° AUTO HAND M22-WR-X91216859
M22S-WR-X91216860
Thumb-grip v 40° – M22-WK216865
M22S-WK216866
V 60° – M22-WRK216867
M22S-WRK216869
10 off
V 60° – M22-WRK-GVP216868
– 50 off
Thumb-grip, V position Z 60° – M22-WKV216874
M22S-WKV216875
5 off
Selector switch actuators, 3 positions, IP66Rotary button 40° x 40° M22-W3
216861M22S-W3216862
5 off
60° X 60° M22-WR3216863
M22S-WR3216864
Thumb-grip 40° x 40° – M22-WK3216870
M22S-WK3216871
60° X 60° – M22-WRK3216872
M22S-WRK3216873
1) – M22-WRK3-*217436
M22S-WRK3-*217437
Coding adapters, for all selector switch actuators
For converting between stay-putand spring-return functions
M22-XC-Y216407
M22-XC-Y216407
10 off
Notes 1) Example: M22-WRK3-*1 = 60° c 40°
2 = 40° C 60°
Moeller HPL0211-2001/2002
RMQ TitanKey-Operated Actuators, Individual Lock Mechanisms
Cont
rol C
ircu
it D
evic
es
02/018
Front ring titanium Front ring black
Function Key withdrawable in position
Type Type PriceV = Stay-put Article no. Article no. See Price
ListStd.packv = Spring-return
Key-operated actuators, IP66
Two positionsIndividual lock mechanisms, not suitable for master key systems, with one keyStay-put/spring-return function and key withdrawability can be changed using M22-XC-... coding adaptersMS1 lock mechanism v 40° 0 M22-WS
216881M22S-WS216882
1 off
V 60° 0 I M22-WRS216887
M22S-WRS216889
5 off
V 60° 0 I M22-WRS-GVP216888
– 25 off
MS2 – 20 lock mechanisms1)
Insert lock mechanism numberinto the type reference
v 40° 0 M22-WS-MS*216883
M22S-WS-MS*216884
1 off
V 60° 0 I M22-WRS-MS*216890
M22S-WRS-MS*216891
1 off
MS1 – 20 lock mechanisms V 50° 0 M22-WRS-MS*-A1217440
M22S-WRS-MS*-A1217441
5 off
Key for MS1 individual lock mechanism
M22-ES-MS1216416
M22-ES-MS1216416
5 off
Key for MS2 – 20 individual lock mechanisms
M22-ES-MS*216417
M22-ES-MS*216417
1 off
Three positionsIndividual lock mechanisms, not suitable for master key systems, with one keyStay-put/spring-return function and key withdrawability can be changed using M22-XC-... coding adaptersMS1 lock mechanism 40° x 40° 0 M22-WS3
216894M22S-WS3216895
1 off
60° X 60° I 0 II M22-WRS3216900
M22S-WRS3216901
5 off
60° X 60° I 0 II M22-WRS3-GVP216902
– 25 off
2) I 0 M22-WRS3-MS*-A*217442
M22S-WRS3-MS*-A*217443
5 off
MS2 – 20 lock mechanismsPlease include lock mechanism numberin the type reference
40° x 40° 0 M22-WS3-MS*216896
M22S-WS3-MS*216897
1 off
60° X 60° I 0 II M22-WRS3-MS*216903
M22S-WRS3-MS*216904
Key for MS1 individual lock mechanism
M22-ES-MS1216416
M22-ES-MS1216416
Key for MS2 – 20 individual lock mechanisms
M22-ES-MS*216417
M22-ES-MS*216417
Set of coding adapters
For converting between the stay-put/spring-return function and key withdrawabilityM22-XC-R216406
M22-XC-R216406
10 off
M22-XC-Y216407
M22-XC-Y216407
10 off
Notes 1) MS2-20: for delivery please enquire2) Example: M22(S)-WRS3-MS*-A* Function Withdrawable in switch position
A1 X 01 – 20 (No. of individual lock mechanism)
A2 X I 0A3 X 0 IIA4 c I 0A5 c 0A6 C 0 IIA7 C 0
Cont
rol C
ircu
it D
evic
es
02/019Moeller HPL0211-2001/2002
RMQ TitanKey-Operated Actuators for Master Key Systems
Front ring titanium Front ring black
Function Key withdrawable in position
Type Type PriceV = Stay-put Article no. Article no. See Price
ListStd.packv = Spring-return
Key-operated actuators IP661)
Two positions Cannot be fitted with coding adaptersWith two keys2)
v 40° 0 M22-WS-SA(*)-*216885
M22S-WS-SA(*)-*216886
1 off
V 60° 0 M22-WRS-SA(*)-*216892
M22S-WRS-SA(*)-*216893
Three positions Cannot be fitted with coding adaptersWith two keys2)
40° x 40° 0 M22-WS3-SA(*)-*216898
M22S-WS3-SA(*)-*216899
60° X 60° 0 M22-WRS3-SA(*)-*216905
M22S-WRS3-SA(*)-*216906
Standard key M22-ES-SA(*)-*217444
M22-ES-SA(*)-*217444
Notes 1) Master key systems: for delivery please enquire
Master key systems• 8000 different lock mechanisms• Security certificate prevents
unauthorized purchase ofkeys; please submit for repeat orders
• Special key profile provided only by themanufacturer
• Moeller master key systems cannot be combined with domestic locks
Lock planExample of a general masterkey system (GHS):The system consists of 12 individuallocks and the associated 12 different keys.At the first level, the locks arecombined to form 3 groups.For each of the 3 groups, there isone group key which can open all thelocks in its group.At the 2nd level, the 3 groups arecombined to form 2 main groups,i.e. the 2nd level master keys canopen all the locks from several groups. The general master keycovers the 2 main groups and canthus open all 12 locks of themaster key system.
1.1
1.2
1.3
1.4
1.5
3.1
3.2
3.3
1
2.1
2.2
2.3
2.4
20
1/2
2/3
3
General master keye.g. for setting-up operation
2nd level master keyse.g. for foremen
Group master keyse.g. for supervisors
Standard key for12 key-operated actuatorse.g. for operating personnel
2) Example: M22-WS-SA(*)-* Level, e.g. 2/3.3.1 Standard keyGroup keyMaster key0 = General master key
For new orders = newFor repeat orders = master key system number according to security certificate
Moeller HPL0211-2001/2002
RMQ TitanIndicator Light Lens Assemblies
Cont
rol C
ircu
it D
evic
es
02/020
Lensstyle
Type PriceArticle no. See Price
ListStd.pack
Indicator lights, IP67, 69KFlush M22-L-W
21677110 off
M22-L-R216772M22-L-G216773M22-L-Y216774M22-L-B216775
Without lens M22-L-X216776
Without lens M22-L-X-GVP216777
50 off
Extended, conical M22-LH-W216778
10 off
M22-LH-R216779M22-LH-G216780M22-LH-Y216781M22-LH-B216782
Acoustic indicator IP40Black front, includes 18 – 30 V DC buzzer,83 dB/10 cm, 100 % DFPositive pole connected to X1
M22-AM216913
10 off
Cont
rol C
ircu
it D
evic
es
02/021Moeller HPL0211-2001/2002
RMQ TitanIlluminated Push-Button Actuators
Front ring titanium Front ring black
Button lensstyle
Type Type PriceArticle no. Article no. See Price
ListStd.pack
Illuminated push-button actuators, IP67, 69KActuator flush, spring-return
M22-DL-W216922
M22S-DL-W216924
10 off
M22-DL-R216925
M22S-DL-R216926
M22-DL-G216927
M22S-DL-G216928
M22-DL-Y216929
M22S-DL-Y216930
M22-DL-B216931
M22S-DL-B216932
Without M22-DL-X216933
M22S-DL-X216935
Without M22-DL-X-GVP216934
– 50 off
M22-DL-R-X0216936
M22S-DL-R-X0216937
10 off
M22-DL-G-X1216938
M22S-DL-G-X1216939
M22-DL-W-X0216940
M22S-DL-W-X0216941
M22-DL-W-X1216942
M22S-DL-W-X1216943
Actuator flush, stay-put
Programmable stay-put/spring-return function
M22-DRL-W216944
M22S-DRL-W216945
5 off
M22-DRL-R216946
M22S-DRL-R216947
M22-DRL-G216948
M22S-DRL-G216949
M22-DRL-Y216950
M22S-DRL-Y216951
M22-DRL-B216952
M22S-DRL-B216953
Without M22-DRL-X216954
M22S-DRL-X216956
Without M22-DRL-X-GVP216955
– 50 off
M22-DRL-R-X0216957
M22-DRL-R-X0216958
5 off
M22-DRL-G-X1216959
M22S-DRL-G-X1216960
M22-DRL-W-X0216961
M22S-DRL-W-X0216962
M22-DRL-W-X1216963
M22S-DRL-W-X1216964
Moeller HPL0211-2001/2002
RMQ TitanIlluminated Push-Button Actuators
Cont
rol C
ircu
it D
evic
es
02/022
Front ring titanium Front ring black
Button lensstyle
Type Type PriceArticle no. Article no. See Price
ListStd.pack
Illuminated push-button actuators, IP67, 69KActuator extended, spring-return
M22-DLH-W216965
M22S-DLH-W216966
5 off
M22-DLH-R216967
M22S-DLH-R216968
M22-DLH-G216969
M22S-DLH-G216970
M22-DLH-Y216971
M22S-DLH-Y216972
M22-DLH-B216973
M22S-DLH-B216974
M22-DLH-R-X0216975
M22S-DLH-R-X0216976
M22-DLH-G-X1216977
M22S-DLH-G-X1216978
M22-DLH-W-X0216979
M22S-DLH-W-X0216980
M22-DLH-W-X1216981
M22S-DLH-W-X1216982
Actuator extended, stay-put
Programmable stay-put/spring-return function
M22-DRLH-W216788
M22S-DRLH-W216791
5 off
M22-DRLH-R216789
M22S-DRLH-R216792
M22-DRLH-G216796
M22S-DRLH-G216798
M22-DRLH-Y216799
M22S-DRLH-Y216801
M22-DRLH-B216802
M22S-DRLH-B216803
M22-DRLH-R-X0216804
M22S-DRLH-R-X0216808
M22-DRLH-G-X1216805
M22S-DRLH-G-X1216809
M22-DRLH-W-X0216806
M22S-DRLH-W-X0216810
M22-DRLH-W-X1216807
M22S-DRLH-W-X1216811
Cont
rol C
ircu
it D
evic
es
02/023Moeller HPL0211-2001/2002
RMQ TitanIlluminated Selector Switch Actuators
Front ring titanium Front ring black
Function Thumb-gripcolour
Type Type PriceV = Stay-put Article no. Article no. See Price
ListStd.packv = Spring-return
Illuminated selector switch actuators, thumb-grip, IP66
Two positionsSpring-return v 40° M22-WLK-W
216812M22S-WLK-W216813
5 off
v 40° M22-WLK-R216814
M22S-WLK-R216815
v 40° M22-WLK-G216816
M22S-WLK-G216817
v 40° M22-WLK-Y216818
M22S-WLK-Y216819
v 40° M22-WLK-B216820
M22S-WLK-B216821
Stay-put V 60° M22-WRLK-W216823
M22S-WRLK-W216824
V 60° M22-WRLK-R216825
M22S-WRLK-R216826
V 60° M22-WRLK-G216827
M22S-WRLK-G216828
V 60° M22-WRLK-Y216829
M22S-WRLK-Y216830
V 60° M22-WRLK-B216831
M22S-WRLK-B216832
Three positionsSpring-return 40° x 40° M22-WLK3-W
216833M22S-WLK3-W216834
5 off
40° x 40° M22-WLK3-R216835
M22S-WLK3-R216836
40° x 40° M22-WLK3-G216837
M22S-WLK3-G216838
40° x 40° M22-WLK3-Y216839
M22S-WLK3-Y216840
40° x 40° M22-WLK3-B216841
M22S-WLK3-B216842
Stay-put 60° X 60° M22-WRLK3-W216843
M22S-WRLK3-W216844
60° X 60° M22-WRLK3-R216845
M22S-WRLK3-R216846
60° X 60° M22-WRLK3-G216847
M22S-WRLK3-G216848
60° X 60° M22-WRLK3-Y216849
M22S-WRLK3-Y216850
60° X 60° M22-WRLK3-B216851
M22S-WRLK3-B216852
Stay-put, spring-return1) M22-WRLK3-*/*217438
M22S-WRLK3-*/*217439
Coding adapters, for all selector switch actuators
For converting between stay-putand spring-return functions
M22-XC-Y216407
M22-XC-Y216407
10 off
Notes 1) Example: M22-WRLK3-*/*1 = c, 2 = C
Colour
Moeller HPL0211-2001/2002
RMQ TitanFixing Adapters, Contact Elements
Cont
rol C
ircu
it D
evic
es
02/024
Contacts1)
M = Make, B = Break,f = Positive opening safety function to IEC/EN 60 947-5-1
Configuration2) Type PriceArticle no. See Price
ListStd.pack
Fixing adapter (front fixing)
For M22-(C)K... contact elements and M22-(C)LED... LED elementsSequence numbers on fixing adapter
M22-A216374
50 off
M22-A-GVP216375
500 off
Contact elements with screw terminals
Front fixing1 M – M22-K10
21637650 off
M22-K10-GVP216377
500 off
– 1 B f M22-K01216378
50 off
M22-K01-GVP216379
500 off
Base fixing1 M – M22-KC10
21638020 off
M22-KC10-GVP216381
200 off
– 1 B f M22-KC01216382
20 off
M22-KC01-GVP216383
200 off
Contact elements with Cage Clamp3)
Front fixing1 M – M22-CK10
21638410 off
– 1 B f M22-CK01216385
10 off
Base fixing1 M – M22-CKC10
21638610 off
– 1 B f M22-CKC01216387
10 off
Complete modules
Combination of contact elements with screw terminals and fixing adapterFront fixing
1 M 1 B f M22-AK11216505
5 off
1 M – M22-AK10216504
– 1 B f M22-AK01216503
Notes 1) x = Sequence numbers on fixing adapter y = Function numbers on contact element
2) Configuration of fixing adapter with sequence numbers to EN 50 0133) Cage Clamp is a registered trademark of Wago Contact Technik GmbH, Minden, Germany
3 21
3 21
.3
.4
0 2.7 5.53 21
.1
.20 1.0 5.5
3 21
.3
.4
0 2.7 5.53 12
.1
.20 1.0 5.5
3 12
.3
.4
0 2.8 5.53 21
.1
.20 1.0 5.5
3 21
.3
.4
0 2.8 5.53 12
.1
.20 1.0 5.5
3 12
21
22
13
14 0 1.0 2.7 5.5
3 21
13
140 2.7 5.5
3 21
21
220 1.0 5.5
3 21
xy
xy
Cont
rol C
ircu
it D
evic
es
02/025Moeller HPL0211-2001/2002
RMQ TitanLED Elements
Type PriceRated operational voltage
Rated operational current
Service lifeat Ta = +25 °C
Colour Article no. See Price List
Std.pack
LED elements with screw terminals
Front fixing18 – 30 V AC/DC 8 – 15 mA 100 000 h M22-LED-W
21655720 off
M22-LED-R216558M22-LED-G216559M22-LED-B218057
85 – 264 V AC 5 – 15 mA,Pmax. = 0.33 W
100 000 h M22-LED230-W216563
20 off
M22-LED230-R216564M22-LED230-G216565M22-LED230-B218059
Base fixing18 – 30 V AC/DC 8 – 15 mA 100 000 h M22-LEDC-W
21656020 off
M22-LEDC-R216561M22-LEDC-G216562M22-LEDC-B218058
85 – 264 V AC 5 – 15 mA,Pmax. = 0.33 W
100 000 h M22-LEDC230-W216566
20 off
M22-LEDC230-R216567M22-LEDC230-G216568M22-LEDC230-B218060
Notes Colour oflens, thumb-grip
r Colour of LED
M22(S)-L(H)-...M22(S)-D(R)L(H)-...M22(S)-W(R)LK-...
-R-G-W-Y-B
rrrrr
-R-G-W-W-W, -B
Moeller HPL0211-2001/2002
RMQ TitanLED Elements
Cont
rol C
ircu
it D
evic
es
02/026
Type PriceRated operational voltage
Rated operational current
Service lifeat Ta = +25 °C
Colour Article no. See Price List
Std.pack
LED elements with Cage Clamp1)
Front fixing18 – 30 V AC/DC 8 – 15 mA 100 000 h M22-CLED-W
21656910 off
M22-CLED-R216570M22-CLED-G216571M22-CLED-B218061
85 – 264 V AC 5 – 15 mA,Pmax. = 0.33 W
100 000 h M22-CLED230-W216575
10 off
M22-CLED230-R216576M22-CLED230-G216577M22-CLED230-B218063
Base fixing18 – 30 V AC/DC 8 – 15 mA 100 000 h M22-CLEDC-W
21657210 off
M22-CLEDC-R216573M22-CLEDC-G216574M22-CLEDC-B218062
85 – 264 V AC 5 – 15 mA,Pmax. = 0.33 W
100 000 h M22-CLEDC230-W216578
10 off
M22-CLEDC230-R216579M22-CLEDC230-G216580M22-CLEDC230-B218064
Notes 1) Cage Clamp is a registered trademark of Wago Contact Technik GmbH, Minden, Germany
Colour oflens, thumb-grip
r Colour of LED
M22(S)-L(H)-...M22(S)-D(R)L(H)-...M22(S)-W(R)LK-...
-R-G-W-Y-B
rrrrr
-R-G-W-W-W, -B
Cont
rol C
ircu
it D
evic
es
02/027Moeller HPL0211-2001/2002
RMQ TitanComplete Legend Plates, Insert Plates
Type PriceArticle no. See Price
ListStd.pack
Complete legend plates
30 x 50 mm, round, black0 I M22S-ST-X88
21648510 off
0 I M22S-ST-X89218147
I 0 II M22S-ST-X93216486
STOP M22S-ST-GB0216494
START M22S-ST-GB1216495
Aus M22S-ST-D5218299
OFF M22S-ST-GB5218300
Ein M22S-ST-D6216487
ON M22S-ST-GB6216496
Fault M22S-ST-D8216489
Störung M22S-ST-GB8216498
Betrieb M22S-ST-D7216488
RUN M22S-ST-GB7216497
HAND AUTO M22S-ST-D11216492
MAN. AUTO M22S-ST-GB11216500
Aus Ein M22S-ST-D10216490
OFF ON M22S-ST-GB10216499
HAND 0 AUTO M22S-ST-D12216493
MAN. 0 AUTO M22S-ST-GB12216501
Insert plates for label mounts, 18 xxxx 27 mm Aluminium, blank M22-XST
216480100 off
Aluminium, blank M22-XST-GVP216481
500 off
With customized inscriptionExtra for quantities of F 10 off
M22-XST-*216482
1 off
Legend plates, without label mount
Round, black, 30 mm wide
M22S-ST-X216392
100 off
M22S-ST-X-GVP216393
500 off
For double actuators M22S-STDD-X216394
10 off
50
Letter height Number of lines Characters per line
3 mm max. 3 max. 125 mm max. 2 max. 8
5075
Moeller HPL0211-2001/2002
RMQ TitanButton Plates
Cont
rol C
ircu
it D
evic
es
02/028
Style: flush Style: extendedText For use with Colour Type Price Type Price
Article no. See Price List
Article no. See Price List
Std.pack
Button plates for push-button actuatorsM22(S)-D-XM22(S)-DR-XM22(S)-DG-X
M22-XD-S216421
M22-XDH-S216428
10 off
M22-XD-W216422
M22-XDH-W216429
M22-XD-R216423
M22-XDH-R216430
M22-XD-G216424
M22-XDH-G216431
M22-XD-Y216425
M22-XDH-Y216432
M22-XD-B216426
M22-XDH-B216433
With customizedinscription1)
M22-XD-*-*216427
M22-XDH-*-*216434
1 off
Zu M22(S)-D-XM22(S)-DR-XM22(S)-DG-X
M22-XD-S-D2218184
M22-XDH-S-D2218229
10 off
Auf M22-XD-S-D3218185
M22-XDH-S-D3218230
Ab M22-XD-S-D4218186
M22-XDH-S-D4218231
Aus M22-XD-R-D5218187
M22-XDH-R-D5218232
Ein M22-XD-S-D6218188
M22-XDH-S-D6218233
Entsperren M22-XD-B-D14218189
M22-XDH-B-D14218234
Vorwärts M22-XD-S-D15218190
M22-XDH-S-D15218235
Rückwärts M22-XD-S-D16218191
M22-XDH-S-D16218236
Heben M22-XD-S-D17218192
M22-XDH-S-D17218237
Senken M22-XD-S-D18218193
M22-XDH-S-D18218238
STOP M22-XD-R-GB0218194
M22-XDH-R-GB0218239
M22-XD-S-GB0218195
M22-XDH-S-GB0218240
START M22-XD-G-GB1218196
M22-XDH-G-GB1218241
M22-XD-W-GB1218197
M22-XDH-W-GB1218242
CLOSE M22-XD-S-GB2218198
M22-XDH-S-GB2218243
UP M22-XD-S-GB3218199
M22-XDH-S-GB3218244
DOWN M22-XD-S-GB4218200
M22-XDH-S-GB4218245
OFF M22-XD-R-GB5218202
M22-XDH-R-GB5218247
ON M22-XD-S-GB6218203
M22-XDH-S-GB6218248
TEST M22-XD-S-GB9218201
M22-XDH-S-GB9218246
RESET M22-XD-B-GB14218204
M22-XDH-B-GB14218249
FORWARD M22-XD-S-GB15218205
M22-XDH-S-GB15218250
REVERSE M22-XD-S-GB16218206
M22-XDH-S-GB16218251
RAISE M22-XD-S-GB17218208
M22-XDH-S-GB17218252
LOWER M22-XD-S-GB18218209
M22-XDH-S-GB18218253
Cont
rol C
ircu
it D
evic
es
02/029Moeller HPL0211-2001/2002
RMQ TitanButton Plates
Style: flush Style: extendedFor use with Colour Type Price Type Price
Symbol Article no. See Price List
Article no. See Price List
Std.pack
Button plates for push-button actuatorsSTOP M22(S)-D-X
M22(S)-DR-XM22(S)-DG-X
M22-XD-R-X0218153
M22-XDH-R-X0218155
10 off
M22-XD-S-X0218154
M22-XDH-S-X0218156
START M22-XD-G-X1218165
M22-XDH-G-X1218210
M22-XD-S-X1218166
M22-XDH-S-X1218211
M22-XD-W-X1218167
M22-XDH-W-X1218212
M22-XD-G-X2218168
M22-XDH-G-X2218213
M22-XD-S-X2218169
M22-XDH-S-X2218214
Increase M22-XD-S-X4218170
M22-XDH-S-X4218215
Decrease M22-XD-S-X5218171
M22-XDH-S-X5218216
Reset M22-XD-B-X6218172
M22-XDH-B-X6218217
Directions of movement
M22-XD-S-X7218173
M22-XDH-S-X7218218
M22-XD-S-X8218174
M22-XDH-S-X8218219
Hand M22-XD-S-X9218175
M22-XDH-S-X9218220
Automatic M22-XD-S-X10218176
M22-XDH-S-X10218221
Inch M22-XD-S-X11218177
M22-XDH-S-X11218222
Unlock M22-XD-S-X12218178
M22-XDH-S-X12218223
Unclamp M22-XD-S-X13218179
M22-XDH-S-X13218224
Clamp M22-XD-S-X14218180
M22-XDH-S-X14218225
Release M22-XD-S-X15218181
M22-XDH-S-X15218226
Liquid M22-XD-S-X16218182
M22-XDH-S-X16218227
Klaxon M22-XD-S-X17218183
M22-XDH-S-X17218228
Notes 1) Example: M22-X...-*-*
Symbol (new or from library, e.g. GB12)
Colour: e.g. -R, -G, -B, -W, -Y
Letter height 3 mm: max. 8 characters in 1st line, 10 characters in 2nd line, 8 characters in 3rd lineLetter height 5 mm: max. 5 characters per lineExtra for quantities of F 9 off + 50 %
8108
5
Moeller HPL0211-2001/2002
RMQ TitanButton Plates
Cont
rol C
ircu
it D
evic
es
02/030
Text For use with Colour Type PriceArticle no. See Price
ListStd.pack
Button plates for mushroom actuatorsM22(S)-DP(R)-... M22-XDP-S
216435 10 off
M22-XDP-W216436M22-XDP-R216437M22-XDP-G216438M22-XDP-Y216439
With customizedinscription1)
M22-XDP-*-*216440
1 off
Zu M22(S)-DP(R)-... M22-XDP-S-D2218272
10 off
Auf M22-XDP-S-D3218273
Ab M22-XDP-S-D4218274
Aus M22-XDP-R-D5218275
Ein M22-XDP-S-D6218276
Vorwärts M22-XDP-S-D15218277
Rückwärts M22-XDP-S-D16218278
Heben M22-XDP-S-D17218279
Senken M22-XDP-S-D18218280
STOP M22-XDP-R-GB0218281M22-XDP-S-GB0218282
START M22-XDP-G-GB1218283M22-XDP-W-GB1218284
CLOSE M22-XDP-S-GB2218285
UP M22-XDP-S-GB3218286
DOWN M22-XDP-S-GB4218287
OFF M22-XDP-R-GB5218289
ON M22-XDP-S-GB6218290
TEST M22-XDP-S-GB9218288
FORWARD M22-XDP-S-GB15218291
REVERSE M22-XDP-S-GB16218292
RAISE M22-XDP-S-GB17218293
LOWER M22-XDP-S-GB18218294
Cont
rol C
ircu
it D
evic
es
02/031Moeller HPL0211-2001/2002
RMQ TitanButton Plates
For use with Colour Type PriceSymbol Article no. See Price
ListStd.pack
Button plates for mushroom actuatorsSTOP M22(S)-DP(R)-... M22-XDP-R-X0
21815710 off
M22-XDP-S-X0218158
START M22-XDP-G-X1218254M22-XDP-S-X1218255M22-XDP-W-X1218256M22-XDP-G-X2218257M22-XDP-S-X2218258
Increase M22-XDP-S-X4218259
Decrease M22-XDP-S-X5218260
Directions of movement
M22-XDP-S-X7218261M22-XDP-S-X8218262
Hand M22-XDP-S-X9218263
Automatic M22-XDP-S-X10218264
Inch M22-XDP-S-X11218265
Unlock M22-XDP-S-X12218266
Unclamp M22-XDP-S-X13218267
Clamp M22-XDP-S-X14218268
Release M22-XDP-S-X15218269
Liquid M22-XDP-S-X16218270
Klaxon M22-XDP-S-X17218271
Notes 1) Example: M22-X...-*-*
Symbol (new or from library, e.g. GB12)
Colour: e.g. -R, -G, -B, -W, -Y
Letter height 3 mm: max. 8 characters in 1st line, 10 characters in 2nd line, 8 characters in 3rd line Letter height 5 mm: max. 5 characters per lineExtra for quantities of F 9 off + 50 %
8108
5
Moeller HPL0211-2001/2002
RMQ TitanLenses
Cont
rol C
ircu
it D
evic
es
02/032
Style: flush Style: extendedText For use with Colour Type Price Type Price
Article no. See Price List
Article no. See Price List
Std.pack
Lenses for indicator lightsM22-L-XM22-LC-X
M22-XL-W216453
M22-XLH-W216459
10 off
M22-XL-R216454
M22-XLH-R216460
M22-XL-G216455
M22-XLH-G216461
M22-XL-Y216456
M22-XLH-Y216462
M22-XL-B216457
M22-XLH-B216463
With customizedinscription1)
M22-XL-*-*216458
– 1 off
Zu M22-L-XM22-LC-X
M22-XL-W-D2218403
– 10 off
Auf M22-XL-W-D3218404
–
Ab M22-XL-W-D4218405
–
Aus M22-XL-R-D5218406
–
Ein M22-XL-W-D6218407
–
Vorwärts M22-XL-W-D15218408
–
Rückwärts M22-XL-W-D16218409
–
Heben M22-XL-W-D17218410
–
Senken M22-XL-W-D18218411
–
STOP M22-XL-R-GB0218412
–
M22-XL-W-GB0218413
–
START M22-XL-G-GB1218414
–
M22-XL-W-GB1218415
–
CLOSE M22-XL-W-GB2218416
–
UP M22-XL-W-GB3218417
–
DOWN M22-XL-W-GB4218418
–
OFF M22-XL-R-GB5218420
–
ON M22-XL-W-GB6218421
–
TEST M22-XL-W-GB9218419
–
FORWARD M22-XL-W-GB15218422
–
REVERSE M22-XL-W-GB16218423
–
RAISE M22-XL-W-GB17218424
–
LOWER M22-XL-W-GB18218425
–
Cont
rol C
ircu
it D
evic
es
02/033Moeller HPL0211-2001/2002
RMQ TitanLenses
Style: flushFor use with Colour Type Price
Symbol Article no. See Price List
Std.pack
Lenses for indicator lightsSTOP M22-L-X
M22-LC-XM22-XL-R-X0218163
10 off
M22-XL-W-X0218164
START M22-XL-G-X1218384M22-XL-W-X1218385M22-XL-G-X2218386M22-XL-W-X2218387
Increase M22-XL-W-X4218388
Decrease M22-XL-W-X5218389
Directions of movement
M22-XL-W-X7218390M22-XL-W-X8218391
Hand M22-XL-W-X9218392
Automatic M22-XL-W-X10218393
Inch M22-XL-W-X11218394
Unlock M22-XL-W-X12218395
Unclamp M22-XL-W-X13218396
Clamp M22-XL-W-X14218399
Release M22-XL-W-X15218400
Liquid M22-XL-W-X16218401
Klaxon M22-XL-W-X17218402
Notes 1) Example: M22-X...-*-*
Symbol (new or from library, e.g. GB12)
Colour: e.g. -R, -G, -B, -W, -Y
Letter height 3 mm: max. 8 characters in 1st line, 10 characters in 2nd line, 8 characters in 3rd line Letter height 5 mm: max. 5 characters per lineExtra for quantities of F 9 off + 50 %
8108
5
Moeller HPL0211-2001/2002
RMQ TitanButton Lenses
Cont
rol C
ircu
it D
evic
es
02/034
Style: flush Style: extendedText For use with Colour Type Price Type Price
Article no. See Price List
Article no. See Price List
Std.pack
Button lenses for illuminated push-button actuatorsM22(S)-DL-XM22(S)-DRL-X
M22-XDL-W216441
M22-XDLH-W216447
10 off
M22-XDL-R216442
M22-XDLH-R216448
M22-XDL-G216443
M22-XDLH-G216449
M22-XDL-Y216444
M22-XDLH-Y216450
M22-XDL-B216445
M22-XDLH-B216451
With customizedinscription1)
M22-XDL-*-*216446
M22-XDLH-*-*216452
1 off
Zu M22(S)-DL-XM22(S)-DRL-X
M22-XDL-W-D2218316
M22-XDLH-W-D2218359
10 off
Auf M22-XDL-W-D3218317
M22-XDLH-W-D3218360
Ab M22-XDL-W-D4218318
M22-XDLH-W-D4218361
Aus M22-XDL-R-D5218319
M22-XDLH-R-D5218362
Ein M22-XDL-W-D6218320
M22-XDLH-W-D6218363
Entsperren M22-XDL-B-D14218321
M22-XDLH-B-D14218364
Vorwärts M22-XDL-W-D15218322
M22-XDLH-W-D15218365
Rückwärts M22-XDL-W-D16218323
M22-XDLH-W-D16218366
Heben M22-XDL-W-D17218324
M22-XDLH-W-D17218367
Senken M22-XDL-W-D18218325
M22-XDLH-W-D18218368
STOP M22-XDL-R-GB0218326
M22-XDLH-R-GB0218369
M22-XDL-W-GB0218327
M22-XDLH-W-GB0218370
START M22-XDL-G-GB1218328
M22-XDLH-G-GB1218371
M22-XDL-W-GB1218329
M22-XDLH-W-GB1218372
CLOSE M22-XDL-W-GB2218330
M22-XDLH-W-GB2218373
UP M22-XDL-W-GB3218331
M22-XDLH-W-GB3218374
DOWN M22-XDL-W-GB4218332
M22-XDLH-W-GB4218375
OFF M22-XDL-R-GB5218334
M22-XDLH-R-GB5218377
ON M22-XDL-W-GB6218335
M22-XDLH-W-GB6218378
TEST M22-XDL-W-GB9218333
M22-XDLH-W-GB9218376
RESET M22-XDL-B-GB14218336
M22-XDLH-B-GB14218379
FORWARD M22-XDL-W-GB15218337
M22-XDLH-W-GB15218380
REVERSE M22-XDL-W-GB16218338
M22-XDLH-W-GB16218381
RAISE M22-XDL-W-GB17218339
M22-XDLH-W-GB17218382
LOWER M22-XDL-W-GB18218340
M22-XDLH-W-GB18218383
Cont
rol C
ircu
it D
evic
es
02/035Moeller HPL0211-2001/2002
RMQ TitanButton Lenses
Style: flush Style: extendedFor use with Colour Type Price Type Price
Symbol Article no. See Price List
Article no. See Price List
Std.pack
Button lenses for illuminated push-button actuatorsSTOP M22(S)-DL-X
M22(S)-DRL-XM22-XDL-R-X0218159
M22-XDLH-R-X0218161
10 off
M22-XDL-W-X0218160
M22-XDLH-W-X0218162
START M22-XDL-G-X1218295
M22-XDLH-G-X1218341
M22-XDL-W-X1218296
M22-XDLH-W-X1218342
M22-XDL-G-X2218297
M22-XDLH-G-X2218343
M22-XDL-W-X2218301
M22-XDLH-W-X2218344
Increase M22-XDL-W-X4218302
M22-XDLH-W-X4218345
Decrease M22-XDL-W-X5218303
M22-XDLH-W-X5218346
Reset M22-XDL-B-X6218304
M22-XDLH-B-X6218347
Directions of movement
M22-XDL-W-X7218305
M22-XDLH-W-X7218348
M22-XDL-W-X8218306
M22-XDLH-W-X8218349
Hand M22-XDL-W-X9218307
M22-XDLH-W-X9218350
Automatic M22-XDL-W-X10218308
M22-XDLH-W-X10218351
Inch M22-XDL-W-X11218309
M22-XDLH-W-X11218352
Unlock M22-XDL-W-X12218310
M22-XDLH-W-X12218353
Unclamp M22-XDL-W-X13218311
M22-XDLH-W-X13218354
Clamp M22-XDL-W-X14218312
M22-XDLH-W-X14218355
Release M22-XDL-W-X15218313
M22-XDLH-W-X15218356
Liquid M22-XDL-W-X16218314
M22-XDLH-W-X16218357
Klaxon M22-XDL-W-X17218315
M22-XDLH-W-X17218358
Notes 1) Example: M22-X...-*-*
Symbol (new or from library, e.g. GB12)
Colour: e.g. -R, -G, -B, -W, -Y
Letter height 3 mm: max. 8 characters in 1st line, 10 characters in 2nd line, 8 characters in 3rd line Letter height 5 mm: max. 5 characters per lineExtra for quantities of F 9 off + 50 %
8108
5
Moeller HPL0211-2001/2002
RMQ TitanFlush Mounting Panels, Shrouds
Cont
rol C
ircu
it D
evic
es
02/036
Degree of protection
Number of locations
Cable entryknockouts
Type PriceArticle no. See Price
ListStd.pack
Colour1) Quantity x M20
Flush mounting panels
Legend plates cannot be used if push-buttons are fitted in vertical columnWithout apertures, if required
Aluminium with yellow paint finish for Emergency-Stop buttons
IP54 1 – M22-EY1216542
5 off
Aluminium, light anodized IP54 1 – M22-E1216541
2 – M22-E2216543
3 – M22-E3216544
4 – M22-E4216545
1 off
5 – M22-E5216546
6 – M22-E6216547
Shrouds
Plastic, light greyIP55 1 3 M22-H1
2165481 off
2 4 M22-H2216549
3 4 M22-H3216550
IP40 4 4 M22-H4216551
5 5 M22-H5216552
6 6 M22-H6216553
Set of plaster keys
Consists of two plaster keys as an aidto flush mounting of shrouds in plaster
– – – – M22-UPE216554
1 off
Notes 1) Yellow RAL 1004, light grey RAL 7035
Cont
rol C
ircu
it D
evic
es
02/037Moeller HPL0211-2001/2002
RMQ TitanSurface Mounting Enclosures
Number of locations
Cable entry knockouts Type Price
Bottom Sides
Article no. See Price List
Std.pack
Quantity xM... Colour1)
Surface mounting enclosure, IP66
With stainless steel screwsFor Emergency-Stop buttons 1 2 x 16 2 x 25/20
1x 20M22-IY1216536
1 off
1 2 x 16 2 x 25/201x 20
M22-I1216535
2 2 x 16 1x 202 x 25/20
M22-I2216537
3 2 x 16 2 x 25/202 x 20
M22-I3216538
4 2 x 16 2 x 25/202 x 20
M22-I4216539
6 2 x 16 2 x 25/202 x 20
M22-I6216540
Surface mounting enclosures, IP55
12 2 x 32/25 4 x 32/252 x 20
M22-I12222688
1 off
Notes 1) Colour: yellow RAL 1004, enclosure cover light grey RAL 7035, enclosure base anthracite RAL 9005
Moeller HPL0211-2001/2002
RMQ TitanAccessories
Cont
rol C
ircu
it D
evic
es
02/038
Type PriceFor use with Colour Article no. See Price
ListStd.pack
Blanking plugs, IP66Round style For blanking off reserve locations M22S-B
21639050 off
M22S-B-GVP216391
250 off
M22-B216388
50 off
M22-B-GVP216389
250 off
Actuator diaphragms for IP67
Transparent diaphragms for severe environmental conditions and use in the food industry. Do not use with legend plates since degree of protection is not guaranteed
M22(S)-D(R)-... push-button actuatorsM22(S)-DL-..., M22(S)-DRL-... illuminated push-button actuatorsM22-L(C)-... flush indicator lights
M22-T-D216395
10 off
M22(S)-DD(L)-... double actuators M22-T-DD216396
10 off
Telescopic clip
For adjusting depth of rear mounting devices in CI enclosures and panels with a mounting depth of 115 – 155 mm. Stepless adjustment, screw fixing and snap fitting (top-hat rail to EN 50 022).Maximum of 10 x M22-TC per enclosure, 5 of which can hold stay-put actuators.Do not use with Emergency-Stop actuators.
For 3 contact/LED elements, base fixing, with centring adapter.
M22-TC216398
10 off
ExtensionFor telescopic clip: for mounting depths up to 205 mm M22-TCV
2255271 off
Centring adapterFor use with M22-TC telescopic clip M22-ZA
21639910 off
IVS top-hat rail adapterFor EN 50 022 top-hat railFor front fixing
M22-IVS216400
1 off
Plunger bridgeFor middle contact on 3-position selector switch, non-illuminated (1 off), black
M22-XW216405
10 off
Cont
rol C
ircu
it D
evic
es
02/039Moeller HPL0211-2001/2002
RMQ TitanAccessories
Type PriceFor use with Colour Article no. See Price
ListStd.pack
Threaded ring
M22 x 1.5 mmM22-GR216401
50 off
M22-GR-GVP216404
500 off
Set of adapter rings 30/22.3 mm
Black, consists of adapter ring and lock nutFor fitting 22.3 mm diameter buttons into 30.5 mm diameter holes
M22S-R30216408
10 off
Combination box spannerFor threaded ring – M22-MS
2164025 off
Fixing plateFor fixing shrouds (M22-H...) to the M22-E.. flush mounting panel for 5 locations
M22-XE5218945
1 off
Indicator lights, Compact, IP67, 69KFlush, with BA 9s lamp socket M22-LC-W
21690710 off
M22-LC-R216908M22-LC-G216909M22-LC-Y216910M22-LC-B216911
Without lens M22-LC-X216912
Extended, with BA 9s lamp socket M22-LCH-W216914M22-LCH-R216915M22-LCH-G216916M22-LCH-Y216917M22-LCH-B216918
Bulb extractorFor M22-LC(H)... For Compact indicator lights
– M22-LG216403
5 off
Inscription and selection softwareM22-TITAN-SELECT222888
1 off
Sheet of adhesive labelsXGKE-GE207517
25 off1)
Notes 1) 1 off = 1 sheet240 labels per sheet
Moeller HPL0211-2001/2002
RMQ TitanAccessories
Cont
rol C
ircu
it D
evic
es
02/040
Type PriceService life to EN 60 064
Colour Article no. See Price List
Std.pack
tmean (AC)at Ta = +25 °C
Blade terminal to DIN 46 244
1 x 6.3 x 0.8/2 x 2.8 x 0.8 mm
For contact and lamp socket elementsUse insulated ferrules to DIN 46 245.
BT483059904
100 off
BA 9s filament bulbs for Compact indicator lights
Maximum length 28 mm, diameter 10 mmMade from selected, high-quality components
110 – 130 V/2.4 W 2000 h GL130074200
50 off
6 V/2.0 W 5000 h GL6078946
12 V/2.0 W 5000 h GL12071827
24 V/2.0 W 5000 h GL24062570
48 V/2.0 W 5000 h GL48076573
60 V/2.0 W 5000 h GL60081319
24 V/1.2 W 5000 h GL24-1.2045097
BA 9s neon bulbs for Compact indicator lights
Maximum length 28 mm, diameter 10 mm110 – 130 V AC/0.1 W 20000 h GIL110K
05521150 off
220 – 240 V AC/0.33 W 20000 h GIL220K057584
50 off
BA 9s single-chip LEDs for Compact indicator lights
For AC and DC(positive pole connected to X1), protected against polarity reversalBuilt-in suppressor circuit up to 1500 V
18 – 30 V AC/DC/15 mA 100000 h LED-W203962
10 off
18 – 30 V AC/DC/15 mA 100000 h LED-R203960
18 – 30 V AC/DC/15 mA 100000 h LED-G203959
18 – 30 V AC/DC/15 mA 100000 h LED-Y203963
18 – 30 V AC/DC/15 mA 100000 h LED-B203961
BA 9s flashing LEDs for Compact indicator lights
For DC (positive pole connected to X1), protected against polarity reversalLED flash rate Q 1.1 Hz, Built-in suppressor circuit up to 1500 V
24 V DC/0.5 W 20000 h (DC) LED-GE24B013195
10 off
24 V DC/0.5 W 20000 h (DC) LED-GN24B015568
24 V DC/0.5 W 20000 h (DC) LED-RT24B017941
Cont
rol C
ircu
it D
evic
es
02/041Moeller HPL0211-2001/2002
RMQ TitanNotes
Moeller HPL0211-2001/2002
RMQ16System Overview
Cont
rol C
ircu
it D
evic
es
02/042
Cont
rol C
ircu
it D
evic
es
02/043Moeller HPL0211-2001/2002
RMQ16System Overview
Emergency-Stop actuators 1Tamper proof to ISO 13 850/EN 418
Illuminated and non-illuminatedAdditional plates with and without text
a Page 02/051
Label mounts 2For insert platesColour: light grey, black, yellowInsert plates with and without text
a Page 02/056
Key-operated actuators 3Two or three positionsSwitching angle 45°Spring-return and stay-putVarious lock mechanisms
a Page 02/046
Break contact element (red) 4With blade terminalUniversal contacts suitable for use with electronic devicesPositive opening safety function toIEC/EN 60 947-5 -1
a Page 02/044
Illuminated push-button actuators 5Spring-return and stay-putInterchangeable insert platesColours: white, green, red, yellow, blue
a Page 02/045
Make contact element (green) 6With blade terminalUniversal contacts suitable for use with electronic devices
a Page 02/044
Selector switch actuators 7Two or three positionsSwitching angle 45°Spring-return and stay-putIlluminated selector switch actuators with integral lamp socket Colours: white, green, red
a Page 02/046
Indicator lights 8Flush and conical versionsIntegral lamp socketFor filament bulbs and LEDsColours: white, green, red, yellow, blue
a Page 02/050
Push-button actuators 9Spring-return and stay-putInterchangeable button platesColours: white, green, red, yellow, blue, black
a Page 02/044
Button plates/insert plates 10Abrasion-proof button plates for push-button actuators
Transparent insert plates for illuminated push-button actuators and indicator lights With and without textWith standard texts and symbols
a Page 02/052
Product features• Front dimension and minimum grid
dimensions 18 x 18 mm or 25 x 25 mm• Mounting diameter 16.2 mm to EN 50 007
• Degree of protection IP65• Switching of different potentials• Can be used with electronic devices to
IEC/EN 61 131-2
• Technical data to IEC/EN 60 947-5-1• Approved throughout the world
Moeller HPL0211-2001/2002
RMQ16Push-Button Actuators, Contact Elements
Cont
rol C
ircu
it D
evic
es
02/044
Square styleFront dimensions:
ContactsM = Make, B = Break,f = Positive opening safety function toIEC/EN 60 947-5-1
Button plate
18 x 18 mm 25 x 25 mmType Type PriceArticle no. Article no. See Price
ListStd.pack
Push-button actuators, IP65Spring-return Q18D-11
086332Q25D-11090471
10 off
Q18D-10086299
Q25D-10090421
Q18D-20054041
Q25D-20054038
Q18D-19054040
Q25D-19054039
Q18D-SW086788
Q25D-SW087230
10 off
Q18D-WS086752
Q25D-WS086808
Q18D-GN086450
Q25D-GN086409
Q18D-RT086713
Q25D-RT086444
Q18D-GE086417
Q25D-GE086343
Q18D-BL086384
Q25D-BL086328
Without Q18D-X093623
Q25D-X093624
Stay-put Q18DR-SW086269
Q25DR-SW088739
10 off
Q18DR-WS086243
Q25DR-WS088701
Q18DR-GN086176
Q25DR-GN088531
Q18DR-RT086209
Q25DR-RT088627
Q18DR-GE090482
Q25DR-GE088404
Q18DR-BL090241
Q25DR-BL088110
Without Q18DR-X093625
Q25DR-X093626
Contact Elements1)
Admissible operational voltage: 5 – 250 V
1 M E10090351
E10090351
50 off
1 B f E01090401
E01090401
50 off
Notes 1) x = Sequence numbers on front element y = Function numbers on contact element
.3
.4
0 2,2 3,7 mm
.1
.2
0 1 3,7 mm
xy
xy
Cont
rol C
ircu
it D
evic
es
02/045Moeller HPL0211-2001/2002
RMQ16Illuminated Push-Button Actuators, Contact Elements
Square styleFront dimensions:
18 x 18 mm 25 x 25 mmLens Type Type Price Notes
Article no. Article no. See Price List
Std.pack
Illuminated push-button actuators, IP65Spring-returnWithout filament bulb
Q18LT-WS089202
Q25LT-WS086262
10 off
Accessories Page
Assembly aids and 02/059accessories
Q18LT-GN089067
Q25LT-GN086206
Q18LT-RT089776
Q25LT-RT086238
Q18LT-GE088808
Q25LT-GE086173
Q18LT-BL088764
Q25LT-BL090479
With filament bulb, 24 V Q18LT-WS/WB088561
Q25LT-WS/WB090226
10 off
Q18LT-GN/WB088509
Q25LT-GN/WB089190
Q18LT-RT/WB088537
Q25LT-RT/WB089998
Q18LT-GE/WB088449
Q25LT-GE/WB089137
Q18LT-BL/WB088338
Q25LT-BL/WB089102
Stay-putWithout filament bulb
Q18LTR-WS088123
Q25LTR-WS087232
10 off
Q18LTR-GN087831
Q25LTR-GN086812
Q18LTR-RT087918
Q25LTR-RT086840
Q18LTR-GE087764
Q25LTR-GE086784
Q18LTR-BL086813
Q25LTR-BL086739
With filament bulb, 24 V Q18LTR-WS/WB086708
Q25LTR-WS/WB086447
10 off
Q18LTR-GN/WB086413
Q25LTR-GN/WB086380
Q18LTR-RT/WB086448
Q25LTR-RT/WB086412
Q18LTR-GE/WB086382
Q25LTR-GE/WB086346
Q18LTR-BL/WB086348
Q25LTR-BL/WB086330
Contact elements1)
Admissible operational voltage: 5 – 250 V
1 M E10090351
E10090351
50 off
1 B f E01090401
E01090401
50 off
Notes 1) x = Sequence numbers on front element y = Function numbers on contact element
xy
xy
Moeller HPL0211-2001/2002
RMQ16Selector Switch Actuators, Key-Operated Actuators, Contact Elements
Cont
rol C
ircu
it D
evic
es
02/046
Square styleFront dimensions:
18 x 18 mm 25 x 25 mmFunction = Stay-put= Spring-return
ContactsM = Make, B = Break,f = Positive opening safety function to IEC/EN 60 947-5-1
Key withdrawable in position
Colour Type Type PriceArticle no. Article no. See Price
ListStd.pack
Selector switch actuators, IP65, 2 positions
With VS anti-rotation featurev 45° Q18WK1
036515Q25WK1036599
5 off
V 45° Q18WK1R036598
Q25WK1R036600
5 off
Key-operated actuators, IP65, 2 positions
With 1 key and VS anti-rotation featurev 45° 0 Q18S1
038806Q25S1038773
5 off
V 45° 0 I Q18S1R038805
Q25S1R038772
V 45° 0 Q18S1R-A1072312
Q25S1R-A1072376
Other individual lock mechanisms(each colour corresponds to one lock mechanism)
v 45° 0 Q18S1-GN062148
Q25S1-GN062150
1 off
V 45° 0 I Q18S1R-GN062151
Q25S1R-GN062108
v 45° 0 Q18S1-RT046841
Q25S1-RT046843
V 45° 0 I Q18S1R-RT046837
Q25S1R-RT046839
v 45° 0 Q18S1-WS046849
Q25S1-WS046851
V 45° 0 I Q18S1R-WS046845
Q25S1R-WS046847
v 45° 0 Q18S1-BL045959
Q25S1-BL046835
V 45° 0 I Q18S1R-BL062814
Q25S1R-BL045502
Contact elements1)
Admissible operational voltage: 5 – 250 V
1 M E10090351
E10090351
50 off
1 B f E01090401
E01090401
50 off
Notes 1) x = Sequence numbers on front element y = Function numbers on contact element
.3
.4
0 2,2 3,7 mm
.1
.2
0 1 3,7 mm
xy
xy
Cont
rol C
ircu
it D
evic
es
02/047Moeller HPL0211-2001/2002
RMQ16Selector Switch Actuators, Key-Operated Actuators, Contact Elements
Square styleFront dimensions:
18 x 18 mm 25 x 25 mmFunction = Stay-put= Spring-return
Key withdrawablein position
Colour Type Type Price NotesArticle no. Article no. See Price
ListStd.pack
Selector switch actuators, IP65, 3 positions
With VS anti-rotation feature45° x 45° Q18WK3
072308Q25WK3072372
5 off
Accessories Page
Assembly aids and 02/059accessories
45° X 45° Q18WK3R072309
Q25WK3R072373
45° c 45° Q18WK3R1072310
Q25WK3R1072374
45° C 45° Q18WK3R2072311
Q25WK3R2072375
Key-operated actuators, IP65, 3 positions
With VS anti-rotation feature45° x 45° 0 Q18S3
072313Q25S3072377
5 off
45° X 45° I 0 II Q18S3R072314
Q25S3R072378
5 off
45° X 45° 0 Q18S3R-A1072315
Q25S3R-A1072379
1 off
45° X 45° I 0 Q18S3R-A2072316
Q25S3R-A2072380
45° X 45° 0 II Q18S3R-A3072317
Q25S3R-A3072381
45° c 45° I 0 Q18S3R-A4072318
Q25S3R-A4072382
45° c 45° 0 Q18S3R-A5072319
Q25S3R-A5072383
45° C 45° 0 II Q18S3R-A6072320
Q25S3R-A6072384
45° C 45° 0 Q18S3R-A7072321
Q25S3R-A7072385
Other individual lock mechanisms (each colour corresponds to one lock mechanism)
45° x 45° 0 Q18S3-GN062149
Q25S3-GN062153
1 off
45° X 45° I 0 II Q18S3R-GN062152
Q25S3R-GN062147
45° x 45° 0 Q18S3-RT046842
Q25S3-RT046844
45° X 45° I 0 II Q18S3R-RT046838
Q25S3R-RT046840
45° x 45° 0 Q18S3-WS046850
Q25S3-WS046852
45° X 45° I 0 II Q18S3R-WS046846
Q25S3R-WS046848
45° x 45° 0 Q18S3-BL046368
Q25S3-BL046836
45° X 45° I 0 II Q18S3R-BL064430
Q25S3R-BL045646
Contact elements1)
Admissible operational voltage: 5 – 250 V
1 M E10090351
E10090351
50 off
1 B f E01090401
E01090401
50 off
Notes 1) x = Sequence numbers on front element y = Function numbers on contact element
.3
.4
.1
.2
xy
xy
Moeller HPL0211-2001/2002
RMQ16Illuminated Selector Switch Actuators, Contact Elements
Cont
rol C
ircu
it D
evic
es
02/048
Square styleFront dimensions:
18 x 18 mm 25 x 25 mmFunction = Stay-put= Spring-return
ContactsM = Make, B = Break,f = Positive opening safety function to IEC/EN 60 947-5-1
Thumb-grip colour
Type Type PriceArticle no. Article no. See Price
ListStd.pack
Illuminated selector switch actuators, IP65, 2 positions
With VS anti-rotation featureWithout filament bulb
v 45° Q18LWK1-WS040349
Q25LWK1-WS040658
5 off
v 45° Q18LWK1-RT039337
Q25LWK1-RT040657
v 45° Q18LWK1-GN039336
Q25LWK1-GN040656
V 45° Q18LWK1R-WS040376
Q25LWK1R-WS040661
V 45° Q18LWK1R-RT040351
Q25LWK1R-RT040660
V 45° Q18LWK1R-GN040350
Q25LWK1R-GN040659
Illuminated selector switch actuators, IP65, 3 positions
With VS anti-rotation featureWithout filament bulb
45° x 45° Q18LWK3-WS072322
Q25LWK3-WS072358
5 off
45° x 45° Q18LWK3-RT072323
Q25LWK3-RT072359
45° x 45° Q18LWK3-GN072324
Q25LWK3-GN072360
45° X 45° Q18LWK3R-WS072325
Q25LWK3R-WS072361
45° X 45° Q18LWK3R-RT072326
Q25LWK3R-RT072362
45° X 45° Q18LWK3R-GN072327
Q25LWK3R-GN072363
45° c 45° Q18LWK3R1-WS072328
Q25LWK3R1-WS072364
45° c 45° Q18LWK3R1-RT072329
Q25LWK3R1-RT072365
45° c 45° Q18LWK3R1-GN072330
Q25LWK3R1-GN072366
45° C 45° Q18LWK3R2-WS072331
Q25LWK3R2-WS072367
45° C 45° Q18LWK3R2-RT072332
Q25LWK3R2-RT072368
45° C 45° Q18LWK3R2-GN072333
Q25LWK3R2-GN072369
Contact elements1)
Admissible operational voltage: 5 – 250 V1 M E10
090351E10090351
50 off
1 Bf E01090401
E01090401
50 off
Notes 1) x = Sequence numbers on front element y = Function numbers on contact element
.3
.4
0 2,2 3,7 mm
.1
.2
0 1 3,7 mm
xy
xy
Cont
rol C
ircu
it D
evic
es
02/049Moeller HPL0211-2001/2002
RMQ16Illuminated Selector Switch Actuators, Contact Elements
Square styleFront dimensions:
18 x 18 mm 25 x 25 mmFunction = Stay-put= Spring-return
Thumb-grip colour
Type Type Price NotesArticle no. Article no. See Price
ListStd.pack
Illuminated selector switch actuators, IP65, 2 positions
With VS anti-rotation featureWith filament bulb, 24 V
v 45° Q18LWK1-WS/WB038978
Q25LWK1-WS/WB040379
5 off
Accessories Page
Assembly aids and 02/059accessories
v 45° Q18LWK1-RT/WB038930
Q25LWK1-RT/WB040378
v 45° Q18LWK1-GN/WB038883
Q25LWK1-GN/WB040377
V 45° Q18LWK1R-WS/WB039335
Q25LWK1R-WS/WB040476
V 45° Q18LWK1R-RT/WB039248
Q25LWK1R-RT/WB040381
V 45° Q18LWK1R-GN/WB039247
Q25LWK1R-GN/WB040380
Illuminated selector switch actuators, IP65, 3 positions
With VS anti-rotation featureWith filament bulb, 24 V
45° x 45° Q18LWK3-WS/WB072334
Q25LWK3-WS/WB072346
5 off
45° x 45° Q18LWK3-RT/WB072335
Q25LWK3-RT/WB072347
45° x 45° Q18LWK3-GN/WB072336
Q25LWK3-GN/WB072348
45° X 45° Q18LWK3R-WS/WB072337
Q25LWK3R-WS/WB072349
45° X 45° Q18LWK3R-RT/WB072338
Q25LWK3R-RT/WB072350
45° X 45° Q18LWK3R-GN/WB072339
Q25LWK3R-GN/WB072351
45° c 45° Q18LWK3R1-WS/WB072340
Q25LWK3R1-WS/WB072352
45° c 45° Q18LWK3R1-RT/WB072341
Q25LWK3R1-RT/WB072353
45° c 45° Q18LWK3R1-GN/WB072342
Q25LWK3R1-GN/WB072354
45° C 45° Q18LWK3R2-WS/WB072343
Q25LWK3R2-WS/WB072355
45° C 45° Q18LWK3R2-RT/WB072344
Q25LWK3R2-RT/WB072356
45° C 45° Q18LWK3R2-GN/WB072345
Q25LWK3R2-GN/WB072357
Contact elements1)
Admissible operational voltage: 5 – 250 V
1 M E10090351
E10090351
50 off
1 B f E01090401
E01090401
50 off
Notes 1) x = Sequence numbers on front element y = Function numbers on contact element
.3
.4
.1
.2
xy
xy
Moeller HPL0211-2001/2002
RMQ16Indicator Lights
Cont
rol C
ircu
it D
evic
es
02/050
Square styleFront dimensions:
18 x 18 mm 25 x 25 mmLens Type Type Price
Article no. Article no. See Price List
Std.pack
Indicator lights, IP65FlushWithout filament bulb
Q18LF-WS088406
Q25LF-WS090228
10 off
Q18LF-GN088337
Q25LF-GN090000
Q18LF-RT088387
Q25LF-RT090198
Q18LF-GE088303
Q25LF-GE089252
Q18LF-BL088270
Q25LF-BL089229
With filament bulb, 24 V Q18LF-WS/WB088059
Q25LF-WS/WB089151
10 off
Q18LF-GN/WB087947
Q25LF-GN/WB088828
Q18LF-RT/WB088001
Q25LF-RT/WB089104
Q18LF-GE/WB087915
Q25LF-GE/WB088798
Q18LF-BL/WB087860
Q25LF-BL/WB088761
ConicalWithout filament bulb
Q18LH-WS088705
Q25LH-WS086263
10 off
Q18LH-GN088629
Q25LH-GN086207
Q18LH-RT088655
Q25LH-RT086241
Q18LH-GE088585
Q25LH-GE090481
Q18LH-BL088560
Q25LH-BL090428
With filament bulb, 24 V Q18LH-WS/WB088535
Q25LH-WS/WB090405
10 off
Q18LH-GN/WB088483
Q25LH-GN/WB090312
Q18LH-RT/WB088507
Q25LH-RT/WB090354
Q18LH-GE/WB088448
Q25LH-GE/WB090285
Q18LH-BL/WB088424
Q25LH-BL/WB090240
Cont
rol C
ircu
it D
evic
es
02/051Moeller HPL0211-2001/2002
RMQ16Emergency-Stop Actuators, Emergency-Stop Labels, Contact Elements
Square styleFront dimensions:
25 x 25 mmContactsM = Make, B = Break,f = Positive opening safety function to IEC/EN 60 947-5-1
ColourForm
Type Price NotesArticle no. See Price
ListStd.pack
Emergency-Stop actuators, IP65
Tamper proof to ISO 13 850, EN 418Plunger remains in actuated position when pressed. Pull to release
Non-illuminated Q25PV072370
5 off
Accessories Page
Assembly aids and 02/059accessories
IlluminatedWith integral multiple LED, 24 V DC, Ie = 15 mAPositive pole connected to X1No need to change the bulb
Q25LPV072371
2 off
Emergency-Stop labels, IP65
NOT-AUSEMERGENCY-STOPARRET D‘URGENCEEMERGENZAYellow with black text50 x 50 mmo 60 mm
Square SQT1058874
5 off
Round SRT1058873
5 off
BlankNot suitable for engraving
Square SQ-GE063263
5 off
Round SR-GE063264
5 off
Contact elements1)
Admissible operational voltage: 5 – 250 V1 M E10
09035150 off
1 B f E01090401
50 off
Notes 1) x = Sequence numbers on front element y = Function numbers on contact element
.3
.4
0 2,2 3,7 mm
.1
.2
0 1 3,7 mm
xy
xy
Moeller HPL0211-2001/2002
RMQ16Marking Plates
Cont
rol C
ircu
it D
evic
es
02/052
Button plates For push-button actuators
Transparent insert platesFor illuminated push-button actuators and indicator lights, flush
18 x 18 mm 25 x 25 mm 18 x 18 mm 25 x 25 mmSymbol Type Type Price Symbol Type Type Price
Article no. Article no. See Price List
Article no. Article no. See Price List
Std.pack1)
Marking plates
Symbols to DIN 30 60001TQ18086816
01TQ25091121
01LQ18090231
01LQ25093180
20 off
02TQ18086859
02TQ25091149
– –
03TQ18087766
03TQ25091184
– –
04TQ18087834
04TQ25091442
– –
05TQ18087867
05TQ25091471
– –
06TQ18087920
06TQ25091506
– –
AUS 10TQ18087951
10TQ25091536
10LQ18090243
10LQ25093225
20 off
STOP or OFF 19TQ18054510
19TQ25054508
– –
EIN 11TQ18088007
11TQ25091562
11LQ18090288
11LQ25093242
START or ON 20TQ18054509
20TQ25054507
– –
21TQ18088061
21TQ25091586
– –
Directions 32TQ18088125
32TQ25091618
32LQ18090320
32LQ25093264
20 off
36TQ18088275
36TQ25092592
36LQ18090410
36LQ25093330
Voltage 34TQ18095386
34TQ25092563
34LQ18090368
34LQ25093307
Positive 37TQ18088315
37TQ25092608
37LQ18090434
37LQ25093365
Negative 38TQ18088340
38TQ25092645
38LQ18090488
38LQ25093402
Hand 40TQ18088389
40TQ25092709
40LQ18086178
40LQ25093462
20 off
Automatic 41TQ18088412
41TQ25092774
41LQ18086210
41LQ25093528
ON-OFF, spring-return 43TQ18088426
43TQ25092791
43LQ18086246
43LQ25090501
Unlock 52TQ18088452
52TQ25092825
52LQ18086366
52LQ25090640
Lock 53TQ18088487
53TQ25092874
53LQ18086453
53LQ25090676
Notes 1) Minimum order quantity: 5 off
Cont
rol C
ircu
it D
evic
es
02/053Moeller HPL0211-2001/2002
RMQ16Marking Plates
Button plates For push-button actuators
Transparent insert platesFor illuminated push-button actuators and indicator lights, flush
18 x 18 mm 25 x 25 mm 18 x 18 mm 25 x 25 mmSymbol Type Type Price Symbol Type Type Price
Article no. Article no. See Price List
Article no. Article no. See Price List
Std.pack1)
Marking plates
Symbols to DIN 30 600Unclamp 54TQ18
08851254TQ25093013
54LQ18086755
54LQ25090706
20 off
Clamp 55TQ18088545
55TQ25093032
55LQ18086817
55LQ25090737
Liquid START – 921TQ25047426
63LQ18086861
63LQ25090776
Liquid STOP 63TQ18088566
63TQ25093060
63LQ18086861
63LQ25090776
Klaxon 66TQ18088590
66TQ25093092
66LQ18087800
66LQ25090799
Spindle START – 811TQ25053898
– – 20 off
Spindle STOP – 814TQ25047425
– –
ON-OFF, stay-put 899TQ18089232
899TQ25093063
899LQ18091008
899LQ25093184
Directions of movement 911TQ18089778
911TQ25093100
911LQ18091045
911LQ25093202
912TQ18090181
912TQ25093135
912LQ18091088
912LQ25093228
Fault – – 920LQ18062106
920LQ25062107
80TQ18088631
80TQ25093134
80LQ18087840
80LQ25090825
20 off
81TQ18088663
81TQ25093158
81LQ18087868
81LQ25090854
82TQ18088715
82TQ25093178
82LQ18088343
82LQ25090869
83TQ18088744
83TQ25093197
83LQ18088517
83LQ25090884
84TQ18088766
84TQ25093224
84LQ18088547
84LQ25090916
85TQ18088811
85TQ25093241
85LQ18088567
85LQ25090937
86TQ18089069
86TQ25093257
86LQ18088593
86LQ25090952
87TQ18089107
87TQ25093288
87LQ18088664
87LQ25090990
88TQ18089165
88TQ25093305
88LQ18088721
88LQ25091021
89TQ18089205
89TQ25093329
89LQ18088746
89LQ25091048
Notes 1) Minimum order quantity: 5 off
Moeller HPL0211-2001/2002
RMQ16Marking Plates
Cont
rol C
ircu
it D
evic
es
02/054
Button plates For push-button actuators
Transparent insert platesFor illuminated push-button actuators and indicator lights, flush
18 x 18 mm 25 x 25 mm 18 x 18 mm 25 x 25 mmType Type Price Type Type PriceArticle no. Article no. See Price
ListArticle no. Article no. See Price
ListStd.pack1)
Marking plates
Text2) to DIN 30 640STOP – 110TQ25
093363110LQ18088773
110LQ25091091
20 off
STOP – 112TQ25063748
110LQ18088773
110LQ25091091
ARRET – 310TQ25091446
310LQ18090851
310LQ25092876
START – 111TQ25093399
111LQ18088813
111LQ25091126
20 off
START – 122TQ25063746
111LQ18088813
111LQ25091126
MARCHE – 311TQ25091475
311LQ18090865
311LQ25093017
AUS – 117TQ25093434
117LQ18089073
117LQ25091154
20 off
AUS – 113TQ25063749
117LQ18089073
117LQ25091154
OFF – 217TQ25090911
217LQ18090498
217LQ25092569
ARRET – 317TQ25091508
310LQ18090851
310LQ25092876
EIN – 121TQ25093461
121LQ18089173
121LQ25091188
20 off
EIN – 123TQ25063747
121LQ18089173
121LQ25091188
ON – 221TQ25090934
221LQ18090524
221LQ25092597
MARCHE – 321TQ25091563
311LQ18090865
311LQ25093017
LINKS – 134TQ25093494
134LQ18089234
134LQ25091449
20 off
LEFT – 234TQ25090987
234LQ18090665
234LQ25092611
GAUCHE – 334TQ25092567
334LQ18090882
334LQ25093038
RECHTS – 135TQ25093527
135LQ18089877
135LQ25091477
20 off
RIGHT – 235TQ25091009
235LQ18090699
235LQ25092661
DROITE – 335TQ25092594
335LQ18090910
335LQ25093072
Notes 1) Minimum order quantity: 5 off2) Non-standard inscriptions for button plates and transparent insert plates available upon request. For delivery please enquire
Cont
rol C
ircu
it D
evic
es
02/055Moeller HPL0211-2001/2002
RMQ16Marking Plates
Button plates For push-button actuators
Transparent insert platesFor illuminated push-button actuators and indicator lights, flush
18 x 18 mm 25 x 25 mm 18 x 18 mm 25 x 25 mmType Type Price Type Type PriceArticle no. Article no. See Price
ListArticle no. Article no. See Price
ListStd.pack1)
Marking plates
Text2) to DIN 30 640ZU – 153TQ25
090632153LQ18090185
153LQ25091510
20 off
CLOSE – 253TQ25091089
253LQ18090731
253LQ25092724
FERME – 353TQ25092609
353LQ18090933
353LQ25093104
AUF – 172TQ25090732
172LQ18090206
172LQ25091538
20 off
UP – 272TQ25091124
272LQ18090768
272LQ25092778
MONTEE – 372TQ25092711
372LQ18090949
372LQ25093139
AB – 173TQ25090822
173LQ18090247
173LQ25091565
20 off
DOWN – 273TQ25091152
273LQ18090796
273LQ25092794
DESCENTE – 373TQ25092775
373LQ18090983
373LQ25093163
RESET – 287TQ25091185
287LQ18090820
287LQ25092844
20 off
VOR – 190TQ25090852
190LQ18090291
190LQ25091599
ZURÜCK – 191TQ25090866
191LQ18090496
191LQ25091620
Notes 1) Minimum order quantity: 5 off2) Non-standard inscriptions for button plates and transparent insert plates available upon request. For delivery please enquire
Moeller HPL0211-2001/2002
RMQ16Insert Plates, Label Mounts
Cont
rol C
ircu
it D
evic
es
02/056
Insert plates For Q25T...-X label mounts
Label mountsQ25T... with insert plate
Type Price Type PriceArticle no. See Price
ListArticle no. See Price
ListStd.pack
Insert plates, label mounts
10 x 22 mmBlank, black, can be engraved 01SQ25
037986Q25TS-01046184
20 off
Blank, aluminium-coloured, can be engraved
02SQ25038074
Q25TS-02046185
Blank, yellow, not suitable for engraving
05SQ25063201
Q25TGE-05063259
Insert plate aluminium-coloured or yellowText1) black
10SQ25038268
Q25TS-10046186
11SQ25038269
Q25TS-11046187
32SQ25038270
Q25TS-32046188
90SQ25038271
Q25TS-90046189
93SQ25072300
Q25TS-93072304
STOP 110SQ25038507
Q25TS-110046190
20 off
STOP 110SQ25038507
Q25TS-110046190
ARRET 310SQ25038768
Q25TS-310046191
START 111SQ25038508
Q25TS-111046192
20 off
START 111SQ25038508
Q25TS-111046192
MARCHE 311SQ25038769
Q25TS-311046193
Notes 1) Non-standard inscriptions for insert plates available upon request. For delivery please enquire
Cont
rol C
ircu
it D
evic
es
02/057Moeller HPL0211-2001/2002
RMQ16Insert Plates, Label Mounts
Insert plates For Q25T...-X label mounts
Label mountsQ25T... with insert plate
Type Price Type PriceArticle no. See Price
ListArticle no. See Price
ListStd.pack
Insert plates, label mounts
Insert plate aluminium-coloured or yellowText1) blackAUS 117SQ25
038509Q25TS-117046194
20 off
OFF 217SQ25038728
Q25TS-217046195
ARRET 310SQ25038768
Q25TS-310046191
EIN 121SQ25038579
Q25TS-121046196
20 off
ON 221SQ25038765
Q25TS-221046197
MARCHE 311SQ25038769
Q25TS-311046193
Störung 150SQ25038661
Q25TS-150046198
20 off
FAULT 250SQ25038766
Q25TS-250046199
DEFAUT 386SQ25072302
Q25TS-386072306
Betrieb 183SQ25038727
Q25TS-183046201
20 off
RUN 283SQ25038767
Q25TS-283046203
EN SERVICE 383SQ25038771
Q25TS-383046204
HAND 0 AUTO 197SQ25072301
Q25TS-197072305
20 off
HAND 0 AUTO 197SQ25072301
Q25TS-197072305
MAN. 0 AUTO 397SQ25072303
Q25TS-397072307
NOT-AUS 199SQ25063200
Q25TGE-199063260
20 off
Emergency-Stop 299SQ25063199
Q25TGE-299063261
ARRET D'URGENCE 399SQ25048638
Q25TGE-399063262
Notes 1) Non-standard inscriptions for insert plates available upon request. For delivery please enquire
Moeller HPL0211-2001/2002
RMQ16Enclosures
Cont
rol C
ircu
it D
evic
es
02/058
Colour Type PriceArticle no. See Price
ListStd.pack
Surface mounting enclosure, IP651)
With moulded cover fixing screwsFor conventional wiring or for fitting ILP1 printed circuit boards, a HPL0213, Section 05Enclosure cover light grey2)
Enclosure base black3)
8 locationsWith cable entry knockoutsBottom: 4 x PG 9/13,5Sides: 6 x PG 9/13,5; 1 x PG 13,5
I8046299
1 off
Surface mounting enclosure for configuration of complete units KI8054422
1 off
Flush mounting panel, IP651)
For conventional wiring or for fitting ELP1 printed circuit boards, a HPL0213, Section 058 locations
2) E8054423
1 off
3) E8-SW065212
Flush mounting panel for configuration of complete units 2) KE8054424
3) KE8-SW065211
Cover plates, IP65
For blanking off reserve locations in surface mounting enclosuresor flush mounting panels, grid dimensions 25 x 37.5 mm
Q25AS036602
10 off
Q25AGR048641Q25AGE048640
Label mounts for insert plates
For additional labelling of locations in surface mounting enclosuresor flush mounting panels, grid dimensions 25 x 37.5 mmFor suitable insert plates a Page 02/052
Q25TS-X036601
20 off
Q25TGR-X063257Q25TGE-X063258
Notes 1) Unoccupied locations must be blocked off with blanking plates.Each occupied location must be equipped with a label mount.
2) RAL 70353) RAL 9005
Cont
rol C
ircu
it D
evic
es
02/059Moeller HPL0211-2001/2002
RMQ16Accessories
Service life Colour Type PriceArticle no. See Price
ListStd.pack
tmean (AC)at Ta = +25 °C
Filament bulbs, W 2 x 4.6 d6 V/1.0 W 10000 h WBGL6
09022350 off
12 V/1.0 W 15000 h WBGL12089968
24 – 28 V/1.0 W 7000 h WBGL24089247
Multiple LEDs, W 2 x 4.6 d
For AC/DC6 V/45 mA 60000 h WBLED-GE6
05571110 off
WBLED-GN6055712WBLED-RT6055713
12 V/24 mA 60000 h WBLED-GE12055714WBLED-GN12055715WBLED-RT12055716
Single-Chip LED, W 2 x 4.6 d
Positive pole to X1 Integral suppressor circuit up to 1000 V
18 – 30 V/7 – 12.5 mA 100000 h LEDWB-Y208724
10 off
LEDWB-G208725LEDWB-R208726LEDWB-W208728LEDWB-B208727
Combination box spannerFor lock nuts, with bulb extractor R16-MS
09029710 off
Insulated sleevesFor 2.8 x 0.8 mm fast-on connectors,can be push-fitted from the front
ISH2.8090267
100 off
Fast-on connectors2.8 x 0.8 mm for conductor cross-sections 0.5 – 1 mm² LT306.022.3
058863100 off
Blanking plugs, IP65For blanking off reserve locations, grid spacing 18 x 18 mm Q18BS
03798510 off
For blanking off reserve locations, grid spacing 25 x 25 mm Q25BS036976
10 off
Anti-rotation featureGuard ring as anti-rotation feature for all RMQ16 actuators VS
04630150 off
Moeller HPL0211-2001/2002
RMQ16Accessories
Cont
rol C
ircu
it D
evic
es
02/060
Type PriceFor use with Colour Article no. See Price
ListStd.pack
PCB adapter
For adaptation to printed circuit boards.Lamp socket and contact elements can be fitted directly.
PRA16046302
20 off
Screw adapter IP20
For conductor cross-sections up to 1 x 1.5 mm2, 2 x 0.75 mm2
For break contacts SRA01028101
20 off
For make contacts SRA10028100
For lamp sockets SRAL028099
Individual key
Standard lock mechanism black. Each colour corresponds to a different lock mechanismES16065190
10 off
ES16-GN030742
5 off
ES16-RT030741ES16-WS030743ES16-BL030744
Cont
rol C
ircu
it D
evic
es
02/061Moeller HPL0211-2001/2002
Notes
Moeller HPL0211-2001/2002
Signal TowersSystem Overview
Cont
rol C
ircu
it D
evic
es
02/062
1
2
3
5
6
7
4
4
7
7
Cont
rol C
ircu
it D
evic
es
02/063Moeller HPL0211-2001/2002
Signal TowersSystem Overview
Continuous light 1Easy to assemble with bayonet fittingArrangement of modules as requiredDegree of protection IP54Up to five levels can be actuated individually
Operating mode 100% DFWithout lights
a Page 02/066
Flashing light 2Easy to assemble with bayonet fittingArrangement of modules as requiredDegree of protection IP54Up to five levels can be actuated individuallyOperating mode 100% DFWith filament bulbFlash rate: approx. 1 Hz
a Page 02/066
Strobe light 3Easy to assemble with bayonet fittingArrangement of modules as requiredDegree of protection IP54Up to five levels can be actuated individuallyOperating mode 100% DFFlash power 1 WsFlash rate: approx. 1 Hz
a Page 02/067
Caps 4Colours: red, yellow, green, white, blueFresnel grooves ensure even light distribution
Acoustic indicator 5Easy to assemble with bayonet fittingArrangement of modules as requiredDegree of protection IP20Operating mode 100% DFContinuous or pulsed toneSound pressure: approx. 90 dB at 60 cmFrequency: 2750 Hz
a Page 02/067
Basic module 6Easy to assemble with bayonet fittingDegree of protection IP54For floor mounting or in tubular columnTerminal capacity: 6 x 1.5 mm2
With top cover
a Page 02/066
Accessories 7Spacer tube available in four lengthsStand90° wall mounting bracketMarket-standard four hole fixing
a Page 02/067
Moeller HPL0211-2001/2002
SL... Signal TowersComplete Units
Cont
rol C
ircu
it D
evic
es
02/064
Rated operational voltage
Number of modules
Colour Type PriceArticle no. See Price
ListStd.pack
Ue Configuration
Complete units
Basic module with stand and 100 mm tube with filament bulbContinuous light IP54 230 V AC 3 SL-100-L-RYG/230
2053511 off
24 V AC/DC 3 SL-100-L-RYG/24205352
1 off
Continuous light IP54 230 V AC 2 SL-100-L-RG/230205353
1 off
24 V AC/DC 2 SL-100-L-RG/24205354
1 off
Continuous light IP54 230 V AC 1 SL-100-L-W/230205355
1 off
24 V AC/DC 1 SL-100-L-W/24205356
1 off
Cont
rol C
ircu
it D
evic
es
02/065Moeller HPL0211-2001/2002
SL... Signal TowersComplete Units
Rated operational voltage
Number of modules
Colour Type PriceArticle no. See Price
ListStd.pack
Ue Configuration
Complete units
Basic module with stand and 100 mm tube with filament bulbContinuous light IP54 230 V AC 1 SL-100-L-R/230
2053571 off
24 V AC/DC 1 SL-100-L-R/24205358
1 off
Continuous light IP54 230 V AC 1 SL-100-L-Y/230205359
1 off
24 V AC/DC 1 SL-100-L-Y/24205360
1 off
Strobe light, IP54 230 V AC 1 SL-100-FL230-W205361
1 off
24 V AC/DC 1 SL-100-FL24-W205362
1 off
Strobe light, IP54 230 V AC 1 SL-100-FL230-R205363
1 off
24 V AC/DC 1 SL-100-FL24-R205364
1 off
Acoustic indicator, IP20Pulsed tone
110 – 230 V AC/DC
1 SL-100-AP110-230205365
1 off
12 – 36 V AC/DC
1 SL-100-AP24205366
1 off
Moeller HPL0211-2001/2002
SL... Signal TowersModules
Cont
rol C
ircu
it D
evic
es
02/066
Rated operational voltage
Colour Type PriceArticle no. See Price
ListStd.pack
Ue
Basic module
Black, with top coverWith screw terminals SL-B
2053111 off
With Cage Clamp1) SL-CB218483
1 off
Continuous light moduleWithout filament bulbs SL-L-W
2053121 off
SL-L-R205313SL-L-G205314SL-L-Y205315SL-L-B205316
Flashing light moduleWith filament bulb, also suitable for LED, f Q 1 Hz 24 V AC/DC SL-BL24-W
2053171 off
SL-BL24-R205318SL-BL24-G205319SL-BL24-Y205320SL-BL24-B205321
110 – 130 V AC SL-BL130-W205322
1 off
SL-BL130-R205323SL-BL130-G205324SL-BL130-Y205325SL-BL130-B205326
230 V AC SL-BL230-W205327
1 off
SL-BL230-R205328SL-BL230-G205329SL-BL230-Y205330SL-BL230-B205331
Acoustic indicator module
84 – 92 dB in 60 cmContinuous tonef = 2750 Hz
12 – 36 V AC/DC8 – 12 mA
SL-A24205341
1 off
110 – 230 V AC/DC4 – 8 mA
SL-A110-230205342
Pulsed tone5 Hz at f = 2750 Hz
12 – 36 V AC/DC8 – 12 mA
SL-AP24205343
110 – 230 V AC/DC4 – 8 mA
SL-AP110-230205344
Notes 1) Cage Clamp is a registered trademark of Wago Contact Technik GmbH, Minden, Germany
Cont
rol C
ircu
it D
evic
es
02/067Moeller HPL0211-2001/2002
SL... Signal TowersModules, Accessories
Service life Rated operational voltage
Colour Type PriceArticle no. See Price
ListStd.pack
tmeanat Ta = +25 °C
Ue
Strobe light module
With flash tube, 1 Ws, f Q 1 Hz24 V AC/DCIemax: 190 mA
SL-FL24-W205332
1 off
SL-FL24-R205333SL-FL24-Y205334
110 – 130 V ACIemax: 31 mA
SL-FL130-W205335
1 off
SL-FL130-R205336SL-FL130-Y205337
230 V ACIemax: 28 mA
SL-FL230-W205338
1 off
SL-FL230-R205339SL-FL230-Y205340
AccessoriesStand with spacer
100 mm, black plastic SL-F100205345
1 off
250 mm, black plastic SL-F250205346
400 mm, metal SL-F400215275
800 mm, metal SL-F800215276
Fixing bracket90° for wall mounting
SL-FW205347
1 off
Filament bulbBA 15d, 5 – 7 W
2000 h 24 V SL-L24205348
1 off
5000 h 110 – 130 V SL-L130205349
5000 h 220 – 260 V SL-L230205350
Multiple LEDBA 15d, integral suppressor circuit up to 1500 V
100000 h 18 – 30 V AC/DC 13 – 50 mA
SL-LED-W215278
1 off
100000 h 18 – 30 V AC/DC 13 – 50 mA
SL-LED-R215279
100000 h 18 – 30 V AC/DC 13 – 50 mA
SL-LED-G215280
100000 h 18 – 30 V AC/DC 13 – 50 mA
SL-LED-Y215281
100000 h 18 – 30 V AC/DC 13 – 50 mA
SL-LED-B215282
Set of gaskets, IP65For 3 modules q 4 off To increase degree of protection
to IP65 (not applicable to acoustic indicator)
SL-IP65215277
1 off
Moeller HPL0211-2001/2002
RMQ TitanTechnical Data
Cont
rol C
ircu
it D
evic
es
Cont
rol C
ircu
it D
evic
es
Moeller HPL0211-2001/2002
RMQ TitanTechnical Data
02/068 02/069
Contact elements
LED elements Push-button actuators
Mushroom actuators
Double actuators
Selector switch actuators
Illuminatedselector switchactuators
General technical dataStandards IEC/EN 60 947, VDE 0660
Lifespan, mechanical Operations x 106 5 – 5 0.2 0.1Maximum operating frequency Ops/h 3600 – 3600 3600 2000
Operating force N F 5 – F 5 F 5 –Operating torque Nm – – – – F 0,3Degree of protection to IEC/EN 60 529
IP20 IP20 IP66 IP65 IP66
Climatic proofing Damp heat, constant, to IEC 60 068-2-3Damp heat, cyclical, to IEC 60 068-230
Ambient temperatureMin./Max. °C −25/+70 −25/+701) −25/+70 −25/+70 −25/+70
Mounting position As required As required As required As required As requiredMechanical shock resistance to IEC 60 068-2-27(half-sinusoidal shock, duration 11 ms)
g � 30 � 30 � 30 � 30 � 30
Terminal capacitySolid Min./Max. mm2 0.75/2.5 0.75/2.5 – – –Stranded Min./Max. mm2 0.5/1.5 0.5/1.5 – – –
Dimensions a Page 02/074 – a Page 02/073 a Page 02/073 a Page 02/073ContactsRated impulse withstand voltage Uimp V 6000 6000 – – –Rated insulation voltage Ui V 500 500 – – –Overvoltage category/pollution degree
III/3 III/3 – – –
Control circuit reliability at24 V DC/5 mA Fault probability HF � 10−7, � 1 fault in 107 operations
5 V DC/1 mA Fault probability HF � 5 × 10−6, � 1 fault in 5 × 106 operations
Maximum short-circuit protective deviceFuseless Type PKZM0–10/
FAZ-B6– – – –
Fuse A gG/gL 10 – – – –Switching capacityRated operational current Ie
AC-15115 V A 6 – – – –230 V A 6 – – – –400 V A 4 – – – –500 V A 2 – – – –
DC-1324 V A 3 – – – –42 V A 1,7 – – – –60 V A 1.2 – – – –110 V A 0.8 – – – –220 V A 0.3 – – – –
Lifespan, electricalAC-15
230 V/0.5 A Operations x 106 1.6 – – – –230 V/1.0 A Operations x 106 1.0 – – – –230 V/3.0 A Operations x 106 0.7 – – – –
DC-1312 V/2.8 A Operations x 106 1.2 – – – –
Notes 1) > 200 V AC/60 Hz: –25/+55 °C
Key-operated actuators
Indicator lights Illuminated push-button actuatorsPush-button actuatorsMushroom actuators
Stay-put
Emergency-Stop actuators
General technical dataStandards IEC/EN 60 947, VDE 0660Lifespan, mechanical Operations x 106 0.1 – 1 0.1Maximum operating frequency Ops/h 100 – 1800 600Operating force N – – F 5 F 50Operating torque Nm F 0,5 – – –Degree of protection to IEC/EN 60 529 IP66 IP66 IP66 IP66Climatic proofing Damp heat, constant, to IEC 60 068-2-3
Damp heat, cyclical, to IEC 60 068-2-30
Ambient temperatureMin./Max. °C −25/+70 −25/+70 −25/+70 −25/+70
Mounting position As required As required As required As requiredMechanical shock resistance to IEC 60 068-2-27(half-sinusoidal shock, duration 11 ms)
g � 30 � 30 � 30 � 50
Dimensions a Page 02/073 a Page 02/073 a Page 02/073 a Page 02/073
Moeller HPL0211-2001/2002
RMQ16Technical Data
Cont
rol C
ircu
it D
evic
es
Cont
rol C
ircu
it D
evic
es
Moeller HPL0211-2001/2002
RMQ16Technical Data
Contact elements
Illuminated push-button actuators(stay-put)
Illuminated selector switch actuators
Indicator lights Push-button actuators
(stay-put)
Selector switch actuators
Key-operated actuators
Emergency-Stopactuators
Emergency-Stopactuators1)
illuminated
General technical dataStandards IEC/EN 60 947, VDE 0660 IEC/EN 60 947, VDE 0660Lifespan, mechanical Operations x 105 100 30 (3) 3 – 30 (3) 3 3 0.5 0.5Maximum operating frequency Ops/h 3600 3600 (1800) 1800 – 3600 (1800) 1800 1800 600 600Operating force N 3 4 – – 4 – – 25 25Operating torque Nm – – � 0.2 – – F 0,2 F 0,4 – –Degree of protection to IEC/EN 60 529 IP20 with ISH2,8 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65Climatic proofing Damp heat, constant, to IEC 60 068-2-3
Damp heat, cyclical, to IEC 60 068-2-30Damp heat, constant, to IEC 60 068-2-3Damp heat, cyclical, to IEC 60 068-2-30
Ambient temperatureOpen Min./Max. °C −25/+60 −25/+60 −25/+60 −25/+60 −25/+60 −25/+60 −25/+60 −25/+60 −25/+60Enclosed Min./Max. °C −25/+40 −25/+40 −25/+40 −25/+40 −25/+40 −25/+40 −25/+40 −25/+40 −25/+40
Mounting position As required As required As required As required As required As required As required As required As requiredMechanical shock resistance to IEC 60 068-2-27(half-sinusoidal shock, duration 11 ms)
g 40 40 40 40 40 40 40 40 40
Terminal capacity Min./Max. mm2 0.5/1.0 0.5/1.0 0.5/1.0 0.5/1.0 – – – – 0.5/1.0Blade terminal 2.8 x0.8 mm to DIN 46 244 – – – – 2.8 × 0.8 mmFerrule 2.8 x 0.8 mm to DIN 46 247 and IEC 60 760 – – – – 2.8 × 0.8 mmDimensions a Page 02/078 a Page 02/078 a Page 02/078 a Page 02/078 a Page 02/078 a Page 02/078 a Page 02/078 a Page 02/078 a Page 02/078
ContactsRated impulse withstand voltage Uimp V 4000 800 800 800 Lifespan, electrical AC-15 to IEC/EN 60 947-5-1 at 230 V
Ie = Rated operational currentRated insulation voltage Ui V 250 250 250 250Overvoltage category/pollution degree
III/3 III/3 III/3 III/3
Bemessungsbetriebsspannung Ue Max. V 250 24 24 24Rated operational current Ie Max. A 4 – – –Control circuit reliability at
24 V DC/5 mA Fault probability HF � 10−7, � 1 fault in 107 operations5 V DC/1 mA Fault probability HF � 5 × 10−6, � 1 fault in 5 x 106 operations
Use of insulated ferrule ISH 2.8From Ue � 24 V AC/DC recommendedFrom Ue � 50 V AC or 120 V DC is mandatory, even on unused blade terminals
Maximum short-circuit protective deviceFuseless Type FAZ-B6 – – –Fuse A gG/gL 10 – – –
Switching capacityRated operational current Ie
AC-1524 V A 4 – – –48 V A 4 – – –110 V A 4 – – –230 V A 4 – – –
DC-1324 V A 3 – – –42 V A 1.0 – – –60 V A 0.8 – – –110 V A 0.5 – – –220 V A 0.2 – – –
Notes 1) See illuminated selector switch actuators for contact values
4321.00.90.80.70.60.50.40.30.20.1
0.1
0.2
0.3
0.4
0.5
0.6
0.70.80.91.0
2
3
4
5
E10
E01
� 106
Ie [A]
02/070 02/071
Moeller HPL0211-2001/2002
RMQ16Technical Data
Cont
rol C
ircu
it D
evic
es
Cont
rol C
ircu
it D
evic
es
Moeller HPL0211-2001/2002
RMQ16Technical Data
Moeller HPL0211-2001/2002
SL Signal TowersTechnical Data
Cont
rol C
ircu
it D
evic
es
02/072
General technical dataStandards IEC/EN 60 947, VDE 0660Degree of protection to IEC/EN 60 529 IP54Climatic proofing Damp heat, constant, to IEC 60 068-2-3
Damp heat, cyclical, to IEC 60 068-2-30
Ambient temperatureOpen Min./Max. °C –Enclosed Min./Max. °C −25/+50
Mounting position As requiredMechanical shock resistance to IEC 60 068-2-27(half-sinusoidal shock, duration 11 ms)
g 15
Terminal capacitySolid mm2 2 x 1.5; 1 x 2.5Stranded mm2 2 x 0.5; 1 x 1.5
Dimensions a Page 02/081
ContactsRated impulse withstand voltage Uimp V 4000Rated insulation voltage Ui V 250Overvoltage category/pollution degree
III/3
Cont
rol C
ircu
it D
evic
es
02/073Moeller HPL0211-2001/2002
RMQ TitanDimensions
Actuators and indicators
Push-button actuators
M22-D M22-DH M22-DG M22-DDM22-D, base fixing
Selector switch actuators
M22-W(R)... M22-W(R)K...M22-W(R)LK...
Key-operated actuatorsIndividual lock mechanisms
M22(S)-W(R)S-(MS...)
Master key systems
M22(S)-W(R)S-SA...
Indicator lights
M22-LH M22-L
Illuminated push-button actuatorsM22-DL M22-DLH
Mushroom actuators
M22-DP
Compact indicator lights
M22-LC-..., M22-AM M22-LCH-...
Emergency-Stop actuator
M22-PV, M22S-PVM22-PVL, M22-PVS-...
10 19
1 – 6
o 2
9.7
o 2
9.5
29.7
10 16.4 16.5
o 2
9.7
13.2
54.7
45.3
37.2
1f 0.3
23.7 26.9
47.75
20.6
o 29
.7
25.5
52.5
18 11.5 10 16.4 23.6
o 3
6.5
11.5
41
22
1841
22
75.1
47.9
Moeller HPL0211-2001/2002
RMQ TitanDimensions
Cont
rol C
ircu
it D
evic
es
02/074
Front fixing (style: flush mounting)
Fixing adapter
M22-A
Centring adapter
M22-ZA
Indicator lights/illuminated push-buttons
Push-button with M22-(C)K... IVS top-hat rail adapter
Button, illuminated push-button, indicator lightWith telescopic clip
Foot and palm switches
FAK...
21.5
19.3
3030
21.4
17.8 37
45
10 45
A
71
1010
30
56.7
3.1 35.2
54.5
64.5
4.5
(M4)
M22-D...M22-L...M22-W...M22-P...
22.4
22.4
4.5
10 39 1060 – 10045
2020
M22-D...M22-L...M22-W...M22-P...
M22 - TCV
18
85
34,5
101
36
L-...
M5 � 20
65
40
�94
3 PG 13,5 on side1 PG 13,5 in bottom
××
1 x M22-K... 2 x M22-K... 1 x M22-CK... 2 x M22-CK...A 37.2 37.2 39 39
Cont
rol C
ircu
it D
evic
es
02/075Moeller HPL0211-2001/2002
RMQ TitanDimensions
Front fixing (style: flush mounting) Base fixing (style: surface mounting)Flush mounting panelsM22-E...
Surface mounting enclosuresM22-I...
Type a1 eE (Y) 1 E 2E 3E 4E 5E 6
72105138171204237
5689122155188221
Shrouds M22-H...
Type a2 Cable entry StyleH 1H 2H 3
4275108
3 xM204 x M204 x M20
One-part
H 4H 5H 6
141174207
4 x M205 x M206 x M20
Multi-part
Shroud with plaster keysM22-UPE
Surface mounting enclosures, 12 locationsM22-I12
4 x M4 x 16
a1
e
33
7256
363
2.5
Insulatingplate
33e
66.5
48
M16/M20 M20/M25
17.8
M20M20
56
44
80
a
M4
a2
59
95
M20 M20 M20
4
56 70
M22-H...
e
e + 13 9
9
M22-UPE
M22-H...
F8
26
a2
a2 + 42
a2 + 32
Card toblank offduring plastering
Plaster thicknessless than 8 mm
Plaster thicknessmore than 8 mm
f8
74
23 30
52.2
125
34 5
38.5
160
38.5
142
5.6
193
8050
240
501.
5
M 20M 25M 32
Type Number of locations
a e Cable entries
M22-I (Y) 1 M22-I2M22-I3M22-I4M22-I6
12346
72120153186252
58.5106.5139.5172.5238.5
2 x M162 x M162 x M162 x M162 x M16
3 x M203 x M202 x M252 x M252 x M25
2 x M252 x M254 x M204 x M204 x M20
Moeller HPL0211-2001/2002
RMQ TitanDimensions
Cont
rol C
ircu
it D
evic
es
02/076
Label mounts
M22-ST M22-STDD
Mounting holes with/without lug slot
Grid dimensions to IEC/EN 60 947 Minimum grid dimensions Grid dimensions for various combinations
A f B f
IEC/EN 60 947RMQ Titan min.
3030
5040
D + T-DDPD+DPPVPV+PL-PVDDDD+T-DDDD+STDD
3337303848303330
56555875
Grid dimensions for M22-DD... Grid dimensions for QDD double actuators plus MT-DD diaphragms
30
1535
27.5
47
30
����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������
3.2
24.1
+0,
4 0
22.3 +0,4 0 22.3 +0,4
0
30
50
30
40
A
B
Do not use actuator diaphragms with label mounts, since the label mounts do not comply with IP67.
75
63
30
a f 30
b f
44 b f
58
Do not use actuator diaphragms with label mounts, since the label mounts do not comply with IP67.
Cont
rol C
ircu
it D
evic
es
02/077Moeller HPL0211-2001/2002
RMQ TitanDimensions
Accessories
M22-PL-PV M22-B M22-T-D M22-T-DD
Emergency-Stop label
M22-XAK M22-XZK... M22-XBK1 M22-XYK1
51.6
10.4
48
32
29.5
17
33
�����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������
33
58
23
17
90
d = 0.8
16.5
50
33
3.2
� 22
.5
� 60
12.5
50
50
Moeller HPL0211-2001/2002
RMQ16Dimensions
Cont
rol C
ircu
it D
evic
es
02/078
Actuators and indicators
Square style Q...BS
Q...D-...Q...DR-...
Q...S... Q...WK...
Q...LT-...Q...LTR-...Q...LF-...
Q...LH-... Q...LWK-...
Q25PVQ25LPV
1...6 mm
39 25 18
18
24
4
11
39
13
39
26
39
11
49
16
49
26
49
37 3949
28
25
Cont
rol C
ircu
it D
evic
es
02/079Moeller HPL0211-2001/2002
RMQ16Dimensions
Front fixing
Drilling dimension Grid dimensions to IEC/EN 60 947Q25...
Minimum grid dimensionsQ18...
Mounting distances
Flush mounting panels
E8/E8-SW
Screw adapter
SRA...
Anti-rotation feature
VS
E01, E10
66
18
6
49
58
ISH 2,8
16,2 0+0,2
25
25 1818
b
a
Exposed conductive part (Metal)
Mountingdistances aand b: 5 mm
92
12.5
25.1
136 7
25.1 25.1
37.5 10
0
25
Cutout dimension: 92 94 mm �
18,5
5,6
22
17,8
17,814,9
Moeller HPL0211-2001/2002
RMQ16Dimensions
Cont
rol C
ircu
it D
evic
es
02/080
Surface mounting enclosures
I8
PCB adapter
PRA16
Label mount
Q25TS-...
Blanking plate
Q25AS
153
3030
0.5
PG 9/13.5 PG 13.5 PG 9/13.5
25.1128
37.5
25.1 25.1
5023
.430
100
4 PG 9/13.5
46.8
2 PG 9/13.5
15310
075
3225
Fixing holes: 2 4.5 mm Spacing dimension: 128 mm
12.7
5.08
17.7
10.16 12.7
17.7
Cross-section of solder: 0.6 0.6 mm
25
38
1213
38
13
12
4
25
Cont
rol C
ircu
it D
evic
es
02/081Moeller HPL0211-2001/2002
SL Signal TowersDimensions
SL-100-...complete units SL-F... standWith tube
Number of modules a b1 227 SL-F100 852 289 SL-F250 2353 351 SL-F400 4024 413 SL-F800 8025 475
SL-L-..., SL-FL...SL-BL..., SL-A... modules
SL-B basic moduleWith top cover
SL-FW fixing bracket
a
∅ 68
∅ 20
b12
∅ 5
.519
R 27
� 68
68
� 58
∅ 60
∅ 6062
18
∅ 20
2
593515
85
18
3 � � 6.5
3 � � 4.5
4 � � 5.5
70
�42
50
�54
503 × ∅ 5
35