1 Control Packs Catalogue Including control packs compliant with 2013 Building Regulations: Part L

Upload: others

Post on 18-Jan-2021

12 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

1

Control PacksCatalogue

Including control packs compliant with 2013 Building Regulations: Part L

Page 2: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

Danfoss Limited Ampthill Road

Bedford MK42 9ER

ReceptionTel: 01234 364621

Fax: 01234 219705

UK SalesTel: 01234 320257

Fax: 01234 320297

Customer ServiceTel: 01234 320176

Fax: 01234 320297

TrainingTel: 01234 320131

LiteratureTel: 01234 320131

Technical SupportTel: 01234 320256

Fax: 01234 320297

Republic of IrelandReception

Tel: 1800 930 242

SalesTel: 1800 930 243

Fax: 1800 556 691

Technical SupportTel: 1800 930 244

2

Page 3: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

3

State of the art, temperature controlled auto assembly cell

On-site product testing laboratory used internally and externally for product validation and research

Efficient lean production facility

Contents

What’s Changed in 2013 Building Regulations: Part L? And How To Comply ...................................................................5-8

Product Overview .................................................................................................................................................................................................................................................9

2013 Building Regulations: Part L Compliant Control Packs Vented Systems

2 Zone Pack - Independent Timing for CH and DHW - Dial Room Thermostat (Dwellings up to 150m²) ......................................................14

2 Zone Pack - Independent Timing for CH and DHW - Digital Room Thermostat (Dwellings up to 150m²) ................................................16

2 Zone Pack - Independent Timing for CH and DHW - Wireless System (Dwellings up to 150m²) .....................................................................18

2 Zone Pack - Independent Timing for CH and DHW - Dial Thermostat and 3 Port Valve (Dwellings up to 150m²) ...............................20

2 Zone Pack - Independent Timing for CH and DHW - Digital Thermostat and 3 Port Valve (Dwellings up to 150m²) .........................22

2 Zone Pack - Independent Timing for CH and DHW - Timeswitch and Programmable Thermostat (Dwellings up to 150m²) ......24

3 Zone Pack - Independent Heating Times - Wireless System (Dwellings above 150m²) .........................................................................................25

3 Zone Pack - Independent Heating Times - Dial Room Thermostats (Dwellings above 150m²) ........................................................................27

3 Zone Pack - Independent Heating Times - Digital Room Thermostat (Dwellings above 150m²) ....................................................................30

Unvented Systems

2 Zone Pack - Independent Timing for CH and DHW - Unvented System - Dial Thermostat (Dwellings above 150m²) ......................34

2 Zone Pack - Independent Timing for CH and DHW - Unvented System - Digital Thermostat (Dwellings up to 150m²) ..................36

2 Zone Pack - Independent Timing for CH and DHW - Wireless Unvented System (Dwellings up to 150m²) .............................................38

3 Zone Pack - Independent Heating Times - Unvented System - Dial Thermostats (Dwellings above 150m²) ..........................................40

3 Zone Pack - Independent Heating Times - Unvented System - Digital Room Thermostats (Dwellings above 150m²) .....................42

Combi Systems

2 Zone Pack - Independent Heating Times - Combi System (Dwellings above 150m²) ............................................................................................46

2 Zone Pack - Independent Heating Times - Combi System with Dial Thermostat (Dwellings above 150m²) ...........................................48

2 Zone Pack - Independent Heating Times - Combi System with Digital Thermostat (Dwellings above 150m²) .....................................50

2 Zone Pack - Independent Heating Times - Wireless Combi System (Dwellings above 150m²) ........................................................................52

Other Useful Packs 2 Zone Pack - Integral Boiler Timer - Combi System .........................................................................................................................................................................55

2 Zone Pack - Common Heating Times - Combi System without Timeswitch ................................................................................................................58

3 Zone Pack - Common Heating Times ....................................................................................................................................................................................................60

3 Zone Pack - Common Heating Times - Wireless System ...........................................................................................................................................................62

3 Zone Pack - Common Heating Times - Unvented System .......................................................................................................................................................64

Page 4: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

4

Page 5: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

What’s Changed in 2013 Building Regulations - Part L?

5

Page 6: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

6

From the 6th April 2014, a revised version of Part L Building Regulations came into force. There have been some minor changes to the previous version, the requirements are:

1. The requirement for dwellings under 150m² to have at least two heating zones has now been removed. To provide zone control in such dwellings TRVs (Thermostatic Radiator Valves) should be provided on all radiators (except the room with the room thermostat) on new systems. It is also good practice to install TRVs when replacing a boiler in an existing system as it is convenient and timely to do this while the system is drained down.

2. The Domestic Building Services Compliance Guide now contains specific recommendations for minimum standards when only a part, or parts, of an existing system are being replaced, the following are considered good practice:

i. Hot Water Cylinder - Install a boiler interlock and separate timing for space heating and hot waterii. Boiler - Fit individual radiator controls such as TRV’s on all radiators except those in the room with a room thermostatiii. Radiator - Fit individual radiator controls such as TRV’s on all radiators except those in the room with a room thermostativ. New heating system – existing pipework retained - Minimum standard to fit individual radiator controls such as TRV’s on all radiators except those in the room with a room

thermostat

Recent research at the University of Salford showed that adding a room thermostat and TRVs to a heating system reduced the running costs by up to 40% as well as ensuring that the system operates effectively to deliver comfortable temperatures in every room. Every opportunity should therefore be taken to ensure that all homes in the UK have effective controls, whether the boiler is being replaced or not.

The Danfoss range of TRVs make the job of upgrading radiator valves on a system easier. All Danfoss TRVs are bi-directional with a flow direction selection feature.Thanks to the rotating insert within the valve, the flow direction through the valve can be changed without the need to remove it, ensuring the water flows through the valve in the correct direction and thereby eliminating the risk of water hammer.

Introduction to 2013 Building Regulations: Part LWhat’s changed? And how to comply…

Page 7: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

7

2 Port Valve Control 3 Port Valve Control

Boile

r wit

h H

ot W

ater

Cyl

inde

r

Programmer, Room Thermostat and TRVs Programmer, Room Thermostat and TRVs

Programmable Room Thermostat and TRVs Programmable Room Thermostat and TRVs

Com

bina

tion

Boi

ler

Timeswitch, Room Thermostat and TRVs Programmable Room Thermostat and TRVs

Example layouts for new systems in dwellings up to 150m2 and for replacement boilers in all dwellings to ensure compliance

Key to Symbols

Notes:• It is defined as good practice to fit

thermostatic radiator valves to all radiators when the system is drained down. It is recommended that it should always be done unless the type of existing radiators or pipework layouts makes it impractical.

Boiler Two Port Three Port Auto By-Pass Wheel Head Zone Valve Zone Valve Valve Valve

Lock Shield Thermostatic Room Programmable Radiator Valve Thermostat Room Thermostat

Multi Channel Two Channel Timeswitch Cylinder Programmer Programmer (Single Channel) Thermostat

Junction Wireless or Box Wired Connection

Page 8: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

8

TS715Si (Service Interval Feature)Single channel timeswitch with backlit display plus factory preset clock with automatic BST/

GMT time change.

TP5000Si (Service Interval Feature)5-2 day programmable thermostat offering 2, 4, or 6 events per day. With energy saving chrono-proportional control to reduce operating costs.

Notes:• Systems specified for dwellings over 150m2 will also satisfy compliance for smaller dwellings.

• Where zone valves are installed in smaller dwellings it is always recommended that both time and temperature control of zones are applied. This can be done for little additional cost but provides far more flexible control options for the occupants.

• All of these systems are preferable approaches where only the boiler is replaced. However pipework changes can incur significant additional work in existing homes so the simplified example layouts for replacement boilers will meet compliance in such circumstances.

Boiler with Hot Water Cylinder Combination Boiler

Dw

ellin

gs o

ver 1

50m

2

Programmable Room Thermostat and TRVs Programmable Room Thermostat with TRVs

Multi-Channel Programmer, Room Thermostat and TRVs Two Heating Zone Programmer, Room Thermostat and TRVs

Key to Symbols

Example layouts for new systems in dwellings over 150m2 to ensure compliance

Boiler Two Port Three Port Auto By-Pass Wheel Head Lock Shield Thermostatic Room Programmable Multi Channel Two Channel Timeswitch Cylinder Junction Wireless or Zone Valve Zone Valve Valve Valve Valve Radiator Valve Thermostat Room Thermostat Programmer Programmer (Single Channel) Thermostat Box Wired Connection

Page 9: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

9

FP715Si (Service Interval Feature)Two channel programmer with independent HW and CH times plus a factory pre-set clock

with automatic BST/GMT time change.

HP22/HS3All Danfoss motorised valves are designed to be

long lasting and reliable.

ATCAn electro-mechanical surface mounted cylinder thermostat with cable strain relief and a simple

fitting to attach to the cylinder.

CET2000B-RF and RX1-S ReceiverA wireless hot water cylinder thermostat. A

strap on sensor connects to the control unit to wirelessly send signals to the RX receiver unit.

TP5000Si-RF (Service Interval Feature)Building on the ease of use of the hard wired

TP5000Si, the TP5000Si-RF is a wireless version enabling positioning anywhere in the house.

WC4BThe WC4B wiring centre provides a systemised

and tidy approach to wiring.

RET2000B-RF and RX1-S ReceiverA wireless digital room thermostat with an LCD temperature display. RX receiver activates the motorised valves when there is a call for heat.

Part L Control PacksProduct Overview

* TRV Combi PackCombines a sensor with the RA-FS ‘revolver’ valve. The patented ‘revolver’ feature allows installation

in either the flow or return.

* TRVs are not supplied within the packs but can be purchased separately from your local merchant.

Control Packs Product Overview

RET230PThe RET230P electronic room thermostat has a discreet design with first class control accuracy

and energy efficiency.

RET1000MSThe RET1000 electronic room thermostat

features stylish backlit LED icons that provide clear indication of power and output status.

RET2000MSThe RET2000 is a digital room thermostat with

an easy to read display, clearly showing the room temperature and output status of the thermostat.

FP735Si (Service Interval Feature)Full three channel programmer with 7 day,

5-2 day or 24 hour operation.

Page 10: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

10

Page 11: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

2013 Building Regulation - Part LCompliant Packs

11

Page 12: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

12

Page 13: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

13

2013 Building Regulation - Part LControl Packs for

Vented Systems

Page 14: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

14

2 Zone Pack (Dwellings up to 150m²)Independent timing for CH and DHW - Dial Room Thermostat Code Number 087N8500JG

1 x FP715SiTwo channel full programmer

1 x RET1000MSElectronic Room Thermostat

1 x ATCCylinder Thermostat

2 x HP22Two port valve

1 x WC4BWiring Centre

Page 15: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

15

2 Zone Pack (Dwellings up to 150m²)Independent timing for CH and DHW - Dial Room Thermostat Code Number 087N8500JG

Providing separate times for heating and hot water, this pack fulfils the minimum control requirements for dwellings under 150m² using a vented hot water cylinder.

The FP715Si two channel timer is used to provide time control for the heating and hot water zones.

A dial setting RET1000MS thermostat provides the customer with a high level of space heating comfort and control accuracy with the added benefit of chrono-proportional control which can provide up to 10% CO2 and cost savings when compared to a standard mechanical thermostat.

Hot water control is achieved using an ATC cylinder thermostat which is easy to install and set.

This pack is ideal for installations using a standard hot water cylinder.

Potential savings with chrono-proportional control:

Results based on a high efficiency condensing boiler over a 12 hour period.

15

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

L N

L N

Pump

Mains Supply

Boiler

LN

PermLN

Sw.

L

3OFF

1COM

2CALL

ATC Cylinder Thermostat

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

LN

N

HP22 . 2-PORT HW VALVE

N

WC4BWiring Centre

Permanent Links

Links to be made by installer

Note: For boilers with pump overrun,please refer to boiler wiring info.

L N

N

FP715 Si - Two Channel ProgrammerDHWOFF

HTGOFF

DHWON

HTGON

1 2 3 4

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

HP22 . 2-PORT HTG VALVE

NN

L N CALL

RET1000MSRoom Thermostat

ControlEnergy Saving

(%)

Carbon Saving

(%)Mechanical On/Off - -

Electronic On/Off 2.10 2.31Chrono-Proportional 10.35 10.71

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

Page 16: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

16

2 Zone Pack (Dwellings up to 150m²)Independent timing for CH and DHW - Digital Room Thermostat Code Number 087N8500KE

1 x FP715SiTwo channel full programmer

1 x ATCCylinder Thermostat

2 x HP22Two port valve

1 x WC4BWiring Centre

1 x RET2000MSElectronic

Room Thermostat

Page 17: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

17

2 Zone Pack (Dwellings up to 150m²)Independent timing for CH and DHW - Digital Room Thermostat Code Number 087N8500KE

Providing separate times for heating and hot water, this pack fulfils the minimum control requirements for dwellings under 150m² using a vented hot water cylinder.

The FP715Si two channel timer is used to provide time control for the heating and hot water zones.

A digital setting RET2000MS thermostat provides the customer with a high level of space heating comfort and control accuracy with the added benefit of chrono-proportional control which can provide up to 10% CO2 and cost savings when compared to a standard mechanical thermostat.

Hot water control is achieved using an ATC cylinder thermostat which is easy to install and set.

This pack is ideal for installations using a standard hot water cylinder.

Potential savings with chrono-proportional control:

Results based on a high efficiency condensing boiler over a 12 hour period.

17

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

L N

L N

Pump

Mains Supply

Boiler

LN

PermLN

Sw.

L

3OFF

1COM

2CALL

ATC Cylinder Thermostat

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

LN

N

HP22 . 2-PORT HW VALVE

N

WC4BWiring Centre

Permanent Links

Links to be made by installer

Note: For boilers with pump overrun,please refer to boiler wiring info.

L N

N

FP715 Si - Two Channel ProgrammerDHWOFF

HTGOFF

DHWON

HTGON

1 2 3 4

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

HP22 . 2-PORT HTG VALVE

NN

L N CALL

RET1000MSRoom Thermostat

ControlEnergy Saving

(%)

Carbon Saving

(%)Mechanical On/Off - -

Electronic On/Off 2.10 2.31Chrono-Proportional 10.35 10.71

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

Page 18: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

18

2 Zone Pack (Dwellings up to 150m²)Independent Timing for CH and DHW - Wireless System Code Number 087N6500V4

2 x HP22Two port valve

WC4BWiring Centre

1 x RET2000B-RFWireless Electronic Room Thermostat

1 x FP715SiTwo channel full programmer

1 x CET2000B-RFWireless Cylinder Thermostat

2 x RX1-SSingle Channel Receiver

Page 19: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

19

2 Zone Pack (Dwellings up to 150m²)Independent Timing for CH and DHW - Wireless System Code Number 087N6500V4

A wireless solution for systems with a vented hot water cylinder providing a separate timebase for heating and hot water control.

Ideal for situations where running wires is difficult or impossible, the wireless packs provide ease of installation as well as a simple setup with reliable operation.

The FP715Si programmer provides a timebase for heating and hot water, while the RET2000B-RF and the CET2000B-RF provide wireless heating and hot water temperature control respectively.

All Danfoss wireless products use a secure digital radio communication system to ensure reliability and eliminate the possibility of interference with other wireless devices in the home.

This pack is ideal for installations using a vented hot water cylinder where fixed wiring is impractical and undesirable.

Potential savings with chrono-proportional control:

Results based on a high efficiency condensing boiler over a 12 hour period.

19

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

L N

L N

Pump

Mains Supply

Boiler

LN

PermLN

Sw.

L

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

LN

N

HP22 . 2-PORT HTG VALVE HP22 . 2-PORT HW VALVE

NN

WC4BWiring Centre

Permanent Links

Links to be made by installer

Note: For boilers with pump overrun,please refer to boiler wiring info.

LN

RX1-S (RET2000B-RF)

L N

N

FP715 Si - Two Channel ProgrammerDHWOFF

HTGOFF

DHWON

HTGON

1 2 3 4N 3ONL 4

OFF2

COM

LN

RX1-S (CET2000B-RF)

N 3ONL 4

OFF2

COM

ControlEnergy Saving

(%)

Carbon Saving

(%)Mechanical On/Off - -

Electronic On/Off 2.10 2.31Chrono-Proportional 10.35 10.71

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

Page 20: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

20

2 Zone Pack (Dwellings up to 150m²)Independent Timing for CH and DHW - Dial Thermostat and 3 Port Valve Code Number 087N8500KF

1 x FP715SiTwo channel full programmer

1 x RET1000MSElectronic Room Thermostat

1 x ATCCylinder Thermostat

1 x HS3Three Port Mid-position Valve

1 x WC4BWiring Centre

Page 21: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

21

2 Zone Pack (Dwellings up to 150m²)Independent Timing for CH and DHW - Dial Thermostat and 3 Port Valve Code Number 087N8500KF

21

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

WC4BWiring Centre

L N

L N

Mains SupplyPermanent Links

Links to be made by installer

Note: For boilers with pump overrun,please refer to boiler wiring info.

HW.OFF

SW.L

HTG.L

N

Wht/Brn.

Blue Or.Gry

HS3 MID-POSITION VALVE

N

3OFF

1COM

2CALL

ATC Cylinder Thermostat

LN

PermLN

Sw.

L

LN

N

BoilerPum

p

L N

N

FP715 Si - Two Channel ProgrammerDHWOFF

HTGOFF

DHWON

HTGON

1 2 3 4

N

L N CALL

RET1000MSRoom Thermostat

Providing separate times for both heating and hot water, this pack fulfils the minimum control requirements for dwellings under 150m² with a vented hot water cylinder.

The FP715Si two channel timer is used to provide time control for the heating and hot water zones.

A dial setting RET1000MS thermostat provides the customer with a high level of space heating comfort and control accuracy.

Hot water control is achieved using an ATC cylinder thermostat which is easy to install and set, whilst a 3-Port Motorised Valve, helps reduce the complexity of the installation.

This pack is ideal for installations using a standard hot water cylinder.

Potential savings with chrono-proportional control:

Results based on a high efficiency condensing boiler over a 12 hour period.

ControlEnergy Saving

(%)

Carbon Saving

(%)Mechanical On/Off - -

Electronic On/Off 2.10 2.31Chrono-Proportional 10.35 10.71

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

Page 22: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

22

2 Zone Pack (Dwellings up to 150m²)Independent Timing for CH and DHW - Digital Thermostat and 3 Port Valve Code Number 087N8500KG

1 x FP715SiTwo channel full programmer

1 x ATCCylinder Thermostat

1 x HS3Three Port Mid-position Valve

1 x WC4BWiring Centre

1 x RET2000MSElectronic

Room Thermostat

Page 23: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

23

2 Zone Pack (Dwellings up to 150m²)Independent Timing for CH and DHW - Digital Thermostat and 3 Port Valve Code Number 087N8500KG

23

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

WC4BWiring Centre

L N

L N

Mains Supply

HW.OFF

SW.L

HTG.L

N

Wht/Brn.

Blue Or.Gry

HS3 MID-POSITION VALVE

N

3OFF

1COM

2CALL

ATC Cylinder Thermostat

LN

PermLN

Sw.

L

LN

N

BoilerPum

p

N

L N

N

FP715 Si - Two Channel ProgrammerDHWOFF

HTGOFF

DHWON

HTGON

1 2 3 4

L N CALL

RET2000MSRoom Thermostat

Permanent Links

Links to be made by installer

Note: For boilers with pump overrun,please refer to boiler wiring info.

Providing separate times for both heating and hot water, this pack fulfils the minimum control requirements for dwellings under 150m² with a vented hot water cylinder.

The FP715Si two channel timer is used to provide time control for the heating and hot water zones.

A digital RET2000MS thermostat provides the customer with a high level of space heating comfort and control accuracy.

Hot water control is achieved using an ATC cylinder thermostat which is easy to install and set, whilst a 3-Port Motorised Valve, helps reduce the complexity of the installation.

This pack is ideal for installations using a standard hot water cylinder.

Potential savings with chrono-proportional control:

Results based on a high efficiency condensing boiler over a 12 hour period.

ControlEnergy Saving

(%)

Carbon Saving

(%)Mechanical On/Off - -

Electronic On/Off 2.10 2.31Chrono-Proportional 10.35 10.71

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

Page 24: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

24

2 Zone Pack (Dwellings up to 150m²)Independent Timing for CH and DHW - Timeswitch and Programmable Thermostat Code Number 087N8517KJ

1 x ATCCylinder Thermostat

1 x HS3Three Port Mid-position Valve

1 x WC4BWiring Centre

1 x TP5000SiElectronic Programmable

Room Thermostat

1 x TS715SiSingle Channel Timeswitch

Page 25: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

25

2 Zone Pack (Dwellings up to 150m²)Independent Timing for CH and DHW - Timeswitch and Programmable Thermostat Code Number 087N8517KJ

25

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

WC4BWiring Centre

L N

L N

Mains SupplyPermanent Links

Links to be made by installer

Note: For boilers with pump overrun,please refer to boiler wiring info. N L

N

TS715 Si - Single Channel Timeswitch

COM OFF ON

1 2 4

HW.OFF

SW.L

HTG.L

N

Wht/Brn.

Blue Or.Gry

HS3 MID-POSITION VALVE

N

3OFF

1COM

2CALL

ATC Cylinder Thermostat

LN

PermLN

Sw.

L

LN

N

BoilerPum

p

OFF COM ON

1/A 2/B 3/C

TP5000Si -Programmable Room Thermostat

Providing separate times for both heating and hot water, this pack fulfils the minimum control requirements for dwellings under 150m² with a vented hot water cylinder.

Using a TS715Si single channel timeswitch to control the hot water times and a TP5000Si programmable room thermostat to provide independent heating zone timings, this pack provides the ultimate in control and potential energy savings to the end user.

A 3-Port Motorised Valve, helps reduce the complexity of the installation.

The advanced chrono-proportional control offered by the TP5000Si can provide up to 10% CO² and energy savings when compared to a standard mechanical thermostat.

This pack is ideal for installations using a standard hot water cylinder.

Potential savings with chrono-proportional control:

Results based on a high efficiency condensing boiler over a 12 hour period.

ControlEnergy Saving

(%)

Carbon Saving

(%)Mechanical On/Off - -

Electronic On/Off 2.10 2.31Chrono-Proportional 10.35 10.71

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

Page 26: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

26

3 Zone Pack (Dwellings above 150m²)Independent Heating Times - Wireless System Code Number 087N6518CG

3 x HP22Two port valve

WC4BWiring Centre

1 x RX1-SOne Channel Receiver

2 x TP5000RF SiElectronic Programmable

Room Thermostat

1 x RX2CTwo Channel Receiver

1 x TS715SiSingle Channel Timeswitch

1 x CET2000B-RFWireless Cylinder Thermostat

Page 27: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

27

3 Zone Pack (Dwellings above 150m²)Independent Heating Times - Wireless System Code Number 087N6518CG

A wireless solution for systems with a vented hot water cylinder providing an independent timebase for both heating zones and a separate timed channel for hot water control.

Ideal for situations where running wires is difficult or impossible, the wireless packs provide ease of installation as well as a simple setup with reliable operation.

This system uses a single channel timeswitch TS715Si for hot water timing, combined with a CET2000B-RF wireless cylinder thermostat and wireless TP5000RF-Si programmable room thermostats for separate time and temperature control of your heating zones.

All Danfoss wireless products use a secure digital radio communication system to ensure reliability and eliminate the possibility of interference with other wireless devices in the home.

This pack is ideal for installations using a vented hot water cylinder where fixed wiring is impractical and full independent timed control of all zones is required.

Potential savings with chrono-proportional control:

Results based on a high efficiency condensing boiler over a 12 hour period.

27

ControlEnergy Saving

(%)

Carbon Saving

(%)Mechanical On/Off - -

Electronic On/Off 2.10 2.31Chrono-Proportional 10.35 10.71

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

L N

L N

Pump

Mains Supply

Boiler

LN

PermLN

Sw.

L

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

LN

N

HP22 . 2-PORT HTG VALVE(Zone 1)

HP22 . 2-PORT HTG VALVE(Zone 2)

HP22 . 2-PORT HW VALVE

NNN

WC4BWiring Centre

Permanent Links

Links to be made by installer

Note: For boilers with pump overrun,please refer to boiler wiring info. N L

N

TS715 Si - Single Channel Timeswitch

COM OFF ON

1 2 4

N L 2COM

3ON

4OFF

N L COM2

1 ON

1 OFF

2 ON

A B C 1 2 3 4 5 6

COM1

LN

RX2C

RX1-S (CET2000B-RF)

N L

Page 28: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

28

2 x RET1000MSElectronic

Room Thermostat

ATCCylinder Thermostat

3 x HP22Two port valve

WC4BWiring Centre

3 Zone Pack (Dwellings above 150m²)Independent Heating Times - Dial Room Thermostats Code Number 087N9501JV

1 x FP735SiThree channel full programmer

Page 29: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

3 Zone Pack (Dwellings above 150m²)Independent Heating Times - Dial Room Thermostats Code Number 087N9501JV

Providing separate times for two heating and a hot water zone, this pack fulfils the minimum control requirements for dwellings above 150m² using a standard hot water cylinder.

The FP735Si three channel programmer is used to provide time control for the heating and hot water zones.

A dial setting RET1000MS thermostat in each of the heating zones, provides the customer with a high level of space heating comfort and control accuracy with the added benefit of Chrono-proportional control.

Hot water control is achieved using an ATC cylinder thermostat which is easy to install and set.

This pack is ideal for installations using a standard hot water cylinder.

Potential savings with chrono-proportional control:

Results based on a high efficiency condensing boiler over a 12 hour period.

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

WC4BWiring Centre

L N

L N

3ON

2ON

2OFF

1ON

1OFF L N

L N

Pump

Mains Supply

Boiler

LN

PermLN

Sw.

L

3OFF

1COM

2CALL

ATC Cylinder Thermostat

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

LN

N

HP22 . 2-PORT HTG VALVE(Zone 2)

HP22 . 2-PORT HW VALVE

FP 735Si - 3 Channel Programmer

NN

Permanent Links

Links to be made by installer

Note: For boilers with pump overrun,please refer to boiler wiring info.

Aux. Sw.

OU

TIN

MotorL

N

Brn.Blue

Or.

Gry

HP22 . 2-PO

RT HTG

VALVE

(Zone 1)

N

N

L N CALL

RET1000MSRoom Thermostat(Zone 2)

N

LN

CALL

RET1000MS

Room Therm

ostat(Zone 1)

29

ControlEnergy Saving

(%)

Carbon Saving

(%)Mechanical On/Off - -

Electronic On/Off 2.10 2.31Chrono-Proportional 10.35 10.71

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

Page 30: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

30

2 x RET2000MSElectronic

Room Thermostat

ATCCylinder Thermostat

3 x HP22Two port valve

WC4BWiring Centre

3 Zone Pack (Dwellings above 150m²)Independent Heating Times - Digital Room Thermostat Code Number 087N9501JW

1 x FP735SiThree channel full programmer

Page 31: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

31

3 Zone Pack (Dwellings above 150m²)Independent Heating Times - Digital Room Thermostat Code Number 087N9501JW

Providing separate times for two heating and a hot water zone, this pack fulfils the minimum control requirements for dwellings above 150m² using a standard hot water cylinder.

The FP735Si three channel programmer is used to provide time control for the heating and hot water zones.

A digital RET2000MS thermostat in each of the heating zones, provides the customer with a high level of space heating comfort and control accuracy with the added benefit of Chrono-proportional control.

Hot water control is achieved using an ATC cylinder thermostat which is easy to install and set.

This pack is ideal for installations using a standard hot water cylinder.

Potential savings with chrono-proportional control:

Results based on a high efficiency condensing boiler over a 12 hour period.

31

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

WC4BWiring Centre

L N

L N

3ON

2ON

2OFF

1ON

1OFF L N

L N

Pump

Mains Supply

Boiler

LN

PermLN

Sw.

L

N

3OFF

1COM

2CALL

ATC Cylinder Thermostat

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

LN

N

HP22 . 2-PORT HTG VALVE(Zone 2)

HP22 . 2-PORT HW VALVE

FP 735Si - 3 Channel Programmer

NN

Permanent Links

Links to be made by installer

Note: For boilers with pump overrun,please refer to boiler wiring info.

Aux. Sw.

OU

TIN

MotorL

N

Brn.Blue

Or.

Gry

HP22 . 2-PO

RT HTG

VALVE

(Zone 1)

N

L N CALL

RET2000MSRoom Thermostat(Zone 2)

N

LN

CALL

RET2000MS

Room Therm

ostat(Zone 1)

ControlEnergy Saving

(%)

Carbon Saving

(%)Mechanical On/Off - -

Electronic On/Off 2.10 2.31Chrono-Proportional 10.35 10.71

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

Page 32: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

32

Page 33: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

33

2013 Building Regulation - Part LControl Packs for

Unvented Systems

Page 34: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

34

1 x HP22Two port valve

WC4BWiring Centre

1 x FP715SiTwo channel full programmer

2 Zone Pack (Dwellings up to 150m²)Independent Timing for CH and DHW - Unvented System - Dial Room Thermostat Code Number 087N8500KK

1 x RET1000MSElectronic Room Thermostat

Page 35: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

35

2 Zone Pack (Dwellings up to 150m²)Independent Timing for CH and DHW - Unvented System - Dial Room Thermostat Code Number 087N8500KK

Providing separate times for heating and hot water, this pack fulfils the minimum control requirements for dwellings under 150m² using an unvented hot water cylinder.

The FP715Si two channel timer is used to provide time control for the heating and hot water zones.

A dial setting RET1000MS thermostat provides the customer with a high level of space heating comfort and control accuracy with the added benefit of chrono-proportional control which can provide up to 10% CO2 and cost savings when compared to a standard mechanical thermostat.

Hot water control is achieved using the controls prefitted to the unvented hot water cylinder. For wiring and installation detail please refer to the manufacturer’s instructions.

This pack is ideal for installations using a standard unvented hot water cylinder.

Potential savings with chrono-proportional control:

Results based on a high efficiency condensing boiler over a 12 hour period.

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

WC4BWiring Centre

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

HP22 . 2-PORT VALVEHeating

N

LN

LN

FP715 Si - Two Channel Programmer ***DHWOFF

DHWON

HTGON

1 3 4

L NPermL

N Sw. L

L N N

Boiler Pump

L N

L N

Mains Supply HTGOFF

2

Permanent Links

Links to be made by installer

Note: For boilers with pump overrun,please refer to boiler wiring info.

*** Connect to Unvented Cylinder controls (HW zone valve and required controlsare supplied with unvented cylinder)

L N CALL

RET1000MSRoom Thermostat

N

35

ControlEnergy Saving

(%)

Carbon Saving

(%)Mechanical On/Off - -

Electronic On/Off 2.10 2.31Chrono-Proportional 10.35 10.71

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

Page 36: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

36

1 x HP22Two port valve

WC4BWiring Centre

1 x FP715SiTwo channel full programmer

2 Zone Pack (Dwellings up to 150m²)Independent Timing for CH and DHW - Unvented System - Digital Room Thermostat Code Number 087N8500KL

1 x RET2000MSElectronic

Room Thermostat

Page 37: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

37

2 Zone Pack (Dwellings up to 150m²)Independent Timing for CH and DHW - Unvented System - Digital Room Thermostat Code Number 087N8500KL

Providing separate times for heating and hot water, this pack fulfils the minimum control requirements for dwellings under 150m² using an unvented hot water cylinder.

The FP715Si two channel timer is used to provide time control for the heating and hot water zones.

A digital RET2000MS thermostat provides the customer with a high level of space heating comfort and control accuracy with the added benefit of chrono-proportional control which can provide up to 10% CO2 and cost savings when compared to a standard mechanical thermostat.

Hot water control is achieved using the controls prefitted to the unvented hot water cylinder. For wiring and installation detail please refer to the manufacturer’s instructions.

This pack is ideal for installations using a standard unvented hot water cylinder.

Potential savings with chrono-proportional control:

Results based on a high efficiency condensing boiler over a 12 hour period.

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

WC4BWiring Centre

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

HP22 . 2-PORT VALVEHeating

N

LN

LN

FP715 Si - Two Channel Programmer ***DHWOFF

DHWON

HTGON

1 3 4

L NPermL

N Sw. L

L N N

Boiler Pump

L N

L N

Mains Supply HTGOFF

2

Permanent Links

Links to be made by installer

Note: For boilers with pump overrun,please refer to boiler wiring info.

*** Connect to Unvented Cylinder controls (HW zone valve and required controlsare supplied with unvented cylinder)

N

L N CALL

RET2000MSRoom Thermostat

37

ControlEnergy Saving

(%)

Carbon Saving

(%)Mechanical On/Off - -

Electronic On/Off 2.10 2.31Chrono-Proportional 10.35 10.71

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

Page 38: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

38

2 Zone Pack (Dwellings up to 150m²)Independent Timing for CH and DHW - Wireless Unvented System Code Number 087N6517CY

1 x HP22Two port valve

WC4BWiring Centre

1 x RX1 Single Channel Receiver

1 x TP5000RF-SiElectronic Programmable

Room Thermostat

1 x TS715SiSingle Channel Timeswitch

Page 39: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

39

2 Zone Pack (Dwellings up to 150m²)Independent Timing for CH and DHW - Wireless Unvented System Code Number 087N6517CY

39

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

WC4BWiring Centre

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

HP22 . 2-PORT VALVEHeating

N

L NPermL

N Sw. L

L N N

Boiler Pump

L N

L N

Mains SupplyPermanent Links

Links to be made by installer

Note: For boilers with pump overrun,please refer to boiler wiring info.

*** Connect to Unvented Cylinder controls (HW zone valve and required controlsare supplied with unvented cylinder)

N L

N

TS715 Si - Single Channel Timeswitch ***

COM OFF ON

1 2 4N L 1 2COM

3ON

4OFF

RX1

N L

A wireless solution for systems with an unvented hot water cylinder providing an independent timebase for heating and hot water control.

Ideal for situations where running wires is difficult or impossible, the wireless packs provide ease of installation as well as a simple setup with reliable operation.

Using a wireless TP5000RF-Si programmable room thermostat enables the user full time and temperature control of the heating zone. The hot water zone time is controlled by the TS715Si timeswitch and the other controls (provided by unvented cylinder manufacturer) can be easily integrated into the system.

All Danfoss wireless products use a secure digital radio communication system to ensure reliability and eliminate the possibility of interference with other wireless devices in the home.

This pack is ideal for installations using an unvented hot water cylinder where fixed wiring is impractical and undesirable.

Potential savings with chrono-proportional control:

Results based on a high efficiency condensing boiler over a 12 hour period.

ControlEnergy Saving

(%)

Carbon Saving

(%)Mechanical On/Off - -

Electronic On/Off 2.10 2.31Chrono-Proportional 10.35 10.71

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

Page 40: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

40

2 x HP22Two port valve

WC4BWiring Centre

1 x FP735SiThree channel full programmer

3 Zone Pack (Dwellings above 150m²)Independent Heating Times - Unvented System - Dial Room Thermostats Code Number 087N9501JY

2 x RET1000MSElectronic

Room Thermostat

Page 41: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

41

3 Zone Pack (Dwellings above 150m²)Independent Heating Times - Unvented System - Dial Room Thermostats Code Number 087N9501JY

Providing independent times for both heating zones and a separate timed hot water zone, this pack fulfils the minimum control requirements for dwellings over 150m² using an unvented hot water cylinder.

The FP735Si three channel programmer is used to provide independent time control for both heating and hot water zones.

A dial setting RET1000MS thermostat provides the customer with a high level of space heating comfort and control accuracy in both heating zones with the added benefit of Chrono-proportional control.

Hot water control is achieved using the controls prefitted to the unvented hot water cylinder. For wiring and installation detail please refer to the manufacturer’s instructions.

This pack is ideal for installations using a standard unvented hot water cylinder.

Potential savings with chrono-proportional control:

Results based on a high efficiency condensing boiler over a 12 hour period.

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

3ON

2ON

2OFF

1ON

1OFF L N

L N

Pump

Boiler

LN

PermLN

Sw.

L

LN

N

FP 735Si - 3 Channel Programmer ***

WC4BWiring Centre

Permanent Links

Links to be made by installer

Note: For boilers with pump overrun,please refer to boiler wiring info.

*** Connect to Unvented Cylinder controls (HW zone valve and required controlsare supplied with unvented cylinder)

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

HP22 . 2-PORT HTG VALVE(Zone 2)

N

Aux. Sw.

OU

TIN

MotorL

N

Brn.Blue

Or.

Gry

HP22 . 2-PO

RT HTG

VALVE

(Zone 1)

N

L N

L N

Mains Supply

N

L N CALL

RET1000MSRoom Thermostat(Zone 1)

N

LN

CALL

RET1000MS

Room Therm

ostat(Zone 2)

41

ControlEnergy Saving

(%)

Carbon Saving

(%)Mechanical On/Off - -

Electronic On/Off 2.10 2.31Chrono-Proportional 10.35 10.71

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

Page 42: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

42

2 x HP22Two port valve

WC4BWiring Centre

1 x FP735SiThree channel full programmer

3 Zone Pack (Dwellings above 150m²)Independent Heating Times - Unvented System - Digital Room Thermostats Code Number 087N9501KA

2 x RET2000MSElectronic

Room Thermostat

Page 43: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

43

3 Zone Pack (Dwellings above 150m²)Independent Heating Times - Unvented System - Digital Room Thermostats Code Number 087N9501KA

Providing independent times for both heating zones and a separate timed hot water zone, this pack fulfils the minimum control requirements for dwellings over 150m² using an unvented hot water cylinder.

The FP735Si three channel programmer is used to provide independent time control for both heating and hot water zones.

A digital RET2000MS thermostat provides the customer with a high level of space heating comfort and control accuracy in both heating zones with the added benefit of Chrono-proportional control.

Hot water control is achieved using the controls prefitted to the unvented hot water cylinder. For wiring and installation detail please refer to the manufacturer’s instructions.

This pack is ideal for installations using a standard unvented hot water cylinder.

Potential savings with chrono-proportional control:

Results based on a high efficiency condensing boiler over a 12 hour period.

43

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

3ON

2ON

2OFF

1ON

1OFF L N

L N

Pump

Boiler

LN

PermLN

Sw.

L

LN

N

FP 735Si - 3 Channel Programmer ***

WC4BWiring Centre

Permanent Links

Links to be made by installer

Note: For boilers with pump overrun,please refer to boiler wiring info.

*** Connect to Unvented Cylinder controls (HW zone valve and required controlsare supplied with unvented cylinder)

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

HP22 . 2-PORT HTG VALVE(Zone 2)

N

N

Aux. Sw.

OU

TIN

MotorL

N

Brn.Blue

Or.

Gry

HP22 . 2-PO

RT HTG

VALVE

(Zone 1)

N

L N

L N

Mains Supply

N

L N CALL

RET2000MSRoom Thermostat(Zone 2)

LN

CALL

RET2000MS

Room Therm

ostat(Zone 1)

ControlEnergy Saving

(%)

Carbon Saving

(%)Mechanical On/Off - -

Electronic On/Off 2.10 2.31Chrono-Proportional 10.35 10.71

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

Page 44: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

44

Page 45: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

45

2013 Building Regulation - Part LControl Packs forCombi Systems

Page 46: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

46

2 x HP22Two port valve

WC4BWiring Centre

2 x TP5000SiElectronic Programmable

Room Thermostat

2 Zone Pack (Dwellings above 150m²)Independent Heating Times - Combi System Code Number 087N6520H4

Page 47: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

47

For systems using combination boilers where full programmable control of the heating zones is required. This pack provides heating control over two zones with a separate timebase for each zone.

The fitting of the TP5000Si programmable thermostat to both the living and sleeping zones in the system allows full time and temperature independent control of each zone.

Having separate time/temperature profiling of each zone means the ultimate in comfort and energy savings for the occupier, this, combined with the advanced Chrono-proportional control offered by the TP5000Si can provide up to 10% CO2 and cost savings when compared to a standard mechanical thermostat.

This pack is ideal for installations using a combination boiler where total flexibility and accurate control are demanded for each zone.

Potential savings with chrono-proportional control:

Results based on a high efficiency condensing boiler over a 12 hour period.

47

ControlEnergy Saving

(%)

Carbon Saving

(%)Mechanical On/Off - -

Electronic On/Off 2.10 2.31Chrono-Proportional 10.35 10.71

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

WC4BWiring Centre

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

HP22 . 2-PORT VALVEHeating Zone 1

N

PermL

N Sw. L

L N

Boiler

L N

L N

Mains SupplyPermanent Links

Links to be made by installer

Note: For systems with 230V main switchingboilers, �t a link between terminals 7-11 in wiring centre.

For systems with low voltage switchingboilers, connect terminal 7 to low voltagefeed on boiler (see boiler instructions for more information).

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

HP22 . 2-PORT VALVEHeating Zone 2

N

OFF COM ON

TP5000Si1/A 2/B 3/C

Programmable Room ThermostatHeating Zone 1

OFF COM ON

TP5000Si1/A 2/B 3/C

Programmable Room ThermostatHeating Zone 2

2 Zone Pack (Dwellings above 150m²)Independent Heating Times - Combi System Code Number 087N6520H4

Page 48: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

48

2 Zone Pack (Dwellings above 150m²)Independent Heating Times - Combi System with Dial Thermostat Code Number 087N9501JY

2 x HP22Two port valve

WC4BWiring Centre

1 x FP735SiThree channel full programmer

2 x RET1000MSElectronic

Room Thermostat

Page 49: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

49

For systems using combination boilers where independent heating times for two zones are required. This pack provides heating control over two zones.

The FP735Si provides independent time control for both the living and sleeping zones in the system.

In addition to this, a dial setting RET1000MS thermostat in each of the heating zones, provides the customer with a high level of space heating comfort and control accuracy with the added benefit of Chrono-proportional control.

This pack is ideal for installations using a combination boiler where total flexibility and accurate control are demanded for each zone.

Potential savings with chrono-proportional control:

Results based on a high efficiency condensing boiler over a 12 hour period.

49

ControlEnergy Saving

(%)

Carbon Saving

(%)Mechanical On/Off - -

Electronic On/Off 2.10 2.31Chrono-Proportional 10.35 10.71

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

BoilerPermL

NSw

. L

LN

WC4BWiring Centre

N

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

HP22 . 2-PORT HTG VALVE(Zone 2)

N

N

Aux. Sw.

OU

TIN

MotorL

N

Brn.Blue

Or.

Gry

HP22 . 2-PO

RT HTG

VALVE

(Zone 1)

N

LN

LN

Mains Supply

Permanent Links

Links to be made by installer

Note: For systems with 230V main switchingboilers, �t a link between terminals 7-11 in wiring centre.

For systems with low voltage switchingboilers, connect terminal 7 to low voltagefeed on boiler (see boiler instructions for more information).

3ON

2ON

2OFF

1ON

1OFF L N

L N

FP 735Si - 3 Channel Programmer

L N CALL

RET 1000MSRoom Thermostat(Zone 2)

LN

CALL

RET 1000MS

Room Therm

ostat(Zone 1)

2 Zone Pack (Dwellings above 150m²)Independent Heating Times - Combi System with Dial Thermostat Code Number 087N9501JY

Page 50: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

50

2 Zone Pack (Dwellings above 150m²)Independent Heating Times - Combi System with Digital Thermostat Code Number 087N9501KA

2 x HP22Two port valve

WC4BWiring Centre

1 x FP735SiThree channel full programmer

2 x RET2000MSElectronic

Room Thermostat

Page 51: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

51

For systems using combination boilers where independent heating times for two zones are required. This pack provides heating control over two zones.

The FP735Si provides independent time control for both the living and sleeping zones in the system.

In addition to this, a digital setting RET2000MS thermostat in each of the heating zones, provides the customer with a high level of space heating comfort and control accuracy with the added benefit of Chrono-proportional control.

This pack is ideal for installations using a combination boiler where total flexibility and accurate control are demanded for each zone.

Potential savings with chrono-proportional control:

Results based on a high efficiency condensing boiler over a 12 hour period.

51

ControlEnergy Saving

(%)

Carbon Saving

(%)Mechanical On/Off - -

Electronic On/Off 2.10 2.31Chrono-Proportional 10.35 10.71

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

BoilerPermL

NSw

. L

LN

WC4BWiring Centre

N

RET2000MS Room Thermostat (Zone 2) Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

HP22 . 2-PORT HTG VALVE(Zone 2)

N

N

RET2000MS

Room Therm

ostat (Zone 1)

Aux. Sw.

OU

TIN

MotorL

N

Brn.Blue

Or.

Gry

HP22 . 2-PO

RT HTG

VALVE

(Zone 1)

N

LN

LN

Mains Supply

Permanent Links

Links to be made by installer

Note: For systems with 230V main switchingboilers, �t a link between terminals 7-11 in wiring centre.

For systems with low voltage switchingboilers, connect terminal 7 to low voltagefeed on boiler (see boiler instructions for more information).

3ON

2ON

2OFF

1ON

1OFF L N

L N

FP 735Si - 3 Channel Programmer

L N CALL

LN

CALL

2 Zone Pack (Dwellings above 150m²)Independent Heating Times - Combi System with Digital Thermostat Code Number 087N9501KA

Page 52: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

52

2 Zone Pack (Dwellings above 150m²)Independent Heating Times - Wireless Combi System Code Number 087N6520DG

2 x HP22Two port valve

WC4BWiring Centre

1 x RX2CTwo Channel Receiver

2 x TP5000RF-SiElectronic Programmable

Room Thermostat

Page 53: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

53

2 Zone Pack (Dwellings above 150m²)Independent Heating Times - Wireless Combi System Code Number 087N6520DG

A wireless solution for systems with a combination boiler providing an independent timebase for both heating zones.

Ideal for situations where running wires is difficult or impossible, the wireless packs provide ease of installation as well as a simple setup with reliable operation.

For full independent heating zone control in a system where a combi boiler is used the TP5000Si-RF provides the solution.

Offering programmable times and temperatures, the TP5000Si-RF, when using the chrono proportional control system can save the occupier up to 10% on their heating bills per year.

The added flexibility of the wireless system means the siting of the thermostats is no longer limited to where wires can be easily run.

This pack is ideal for installations using a combi boiler where fixed wiring is impractical and full independent timed control of both heating zones is required.

Potential savings with chrono-proportional control:

Results based on a high efficiency condensing boiler over a 12 hour period.

53

ControlEnergy Saving

(%)

Carbon Saving

(%)Mechanical On/Off - -

Electronic On/Off 2.10 2.31Chrono-Proportional 10.35 10.71

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

LN

LN

Mains Supply

BoilerPermL

NSw

. L

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

LN

HP22 . 2-PORT HTG VALVE(Zone 1)

HP22 . 2-PORT HTG VALVE(Zone 2)

NN

WC4BWiring Centre

A B C 1 2 3 4 5 6

LN

RX2C

N L COM2

1 ON

1 OFF

2 ON

COM1Permanent Links

Links to be made by installer

Note: For boilers with low voltage switching, connect terminal 7 to low voltage feed on boiler (see boiler instructions for more information).

Page 54: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

54

Page 55: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

55

OtherUseful Packs

Page 56: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

56

2 x HP22Two port valve

WC4BWiring Centre

2 x RET230PElectronic Room Thermostat

2 Zone PackIntegral Boiler Timer – Combi System Code Number 087N6520S7

Page 57: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

57

For systems using combination boilers with an integral timeclock; this pack provides heating control over two zones with a common timebase.

The addition of two RET230P electronic room thermostats and two HP22 motorised valves to the combi boiler system provides zone control to both the living and the sleeping areas of the house enabling different comfort levels to be set, saving energy and increasing comfort for the occupier.

This pack is ideal for installations using a combination boiler that is provided with its own integral timeclock.

57

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

2 Zone PackIntegral Boiler Timer – Combi System Code Number 087N6520S7

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

WC4BWiring Centre

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

HP22 . 2-PORT VALVEHeating Zone 1

N

PermL

N Sw. L

L N

Boiler

L N

L N

Mains SupplyPermanent Links

Links to be made by installer

Note: For systems with 230V main switchingboilers, �t a link between terminals 7-11 in wiring centre.

For systems with low voltage switchingboilers, connect terminal 7 to low voltagefeed on boiler (see boiler instructions for more information).

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

HP22 . 2-PORT VALVEHeating Zone 2

N

COM CALL N

N

*

RET230P *L 1 N

Link terminals L and COM in the RET230P for correct operation (See thermostat instructions for further information).

COM CALL N

N

RET230P *L 1 N

Page 58: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

58

2 Zone PackCommon Heating Times – Combi System without Timeswitch Code Number 087N6517S7

2 x HP22Two port valve

WC4BWiring Centre

2 x RET230PElectronic Room Thermostat

1 x TS715SiSingle Channel Timeswitch

Page 59: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

59

2 Zone PackCommon Heating Times – Combi System without Timeswitch Code Number 087N6517S7

For systems using combination boilers where an external timeclock is required. This pack provides heating control over two zones with a common timebase.

The addition of two RET230P electronic room thermostats and two HP22 motorised valves to the combi boiler system provides zone control to both the living and the sleeping areas of the house enabling different comfort levels to be set, saving energy and increasing comfort for the occupier.

This pack is ideal for installations using a combination boiler that is not provided with its own integral timeclock, or for installations where a timeclock is required externally to the combi boiler.

59

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

LN

LN

Mains Supply

BoilerPermL

NSw

. L

COM CALL N

N

RET 230P *Room Thermostat (Zone 2)

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

COM

CALL

N N

RET 230P *Room

Thermostat

(Zone 1)Aux. Sw

.

OU

TIN

MotorL

N

Brn.Blue

Or.

Gry

LN

HP22 . 2-PO

RT HTG

VALVE

(Zone 1)

HP22 . 2-PORT HTG VALVE(Zone 2)

N

N

L 1 N

L1

WC4BWiring Centre

Permanent Links

Links to be made by installer

N

Link terminals L and COM in the RET 230P for correct operation (see thermostat instructions for further information).

* N L

N

TS715 Si - Single Channel Timeswitch

COM OFF ON

1 2 4

Page 60: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

60

1 x FP715SiTwo channel full programmer

2 x RET230PElectronic Room Thermostat

1 x ATCCylinder Thermostat

3 x HP22Two port valve

1 x WC4BWiring Centre

3 Zone PackCommon Heating Times Code Number 087N6500X1

Page 61: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

61

Providing common times for both heating zones and a separate timed hot water zone this pack fulfils the minimum control requirements for dwellings under 150m2 using a vented hot water cylinder.

The FP715Si two channel timer is used to provide time control for the heating and hot water zones.

Dial setting RET230P thermostats provide the customer with a high level of space heating comfort and control accuracy.

Hot water control is achieved using an ATC cylinder thermostat which is easy to install and set.

This pack is ideal for installations using a standard hot water cylinder.

61

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

3 Zone PackCommon Heating Times Code Number 087N6500X1

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

L N

L N

Pump

Mains Supply

Boiler

LN

PermLN

Sw.

L

COM CALL N

N

RET 230P *Room Thermostat (Zone 2)

3OFF

1COM

2CALL

ATC Cylinder Thermostat

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

COM

CALL

N N

RET 230P *Room

Thermostat

(Zone 1)Aux. Sw

.

OU

TIN

MotorL

N

Brn.Blue

Or.

Gry

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

LN

N

HP22 . 2-PO

RT HTG

VALVE

(Zone 1)

HP22 . 2-PORT HTG VALVE(Zone 2)

HP22 . 2-PORT HW VALVE

NN

N

L 1 N

L1

WC4BWiring Centre

Permanent Links

Links to be made by installer

Note: For boilers with pump overrun,please refer to boiler wiring info.

N

L N

N

FP715 Si - Two Channel ProgrammerDHWOFF

HTGOFF

DHWON

HTGON

1 2 3 4

Link terminals L and COM in the RET 230P for correct operation (see thermostat instructions for further information).

*

Page 62: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

62

3 Zone PackCommon Heating Times – Wireless System Code Number 087N6500CB

3 x HP22Two port valve

WC4BWiring Centre

2 x RET2000B-RFWireless Electronic Room Thermostat

1 x FP715SiTwo channel full programmer

1 x CET2000B-RFWireless Cylinder Thermostat

3 x RX1-SSingle Channel Receiver

Page 63: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

63

3 Zone PackCommon Heating Times – Wireless System Code Number 087N6500CB

A wireless solution for systems with a vented hot water cylinder providing a common timebase for both heating zones and a separate timed channel for hot water control.

Ideal for situations where running wires is difficult or impossible, the wireless packs provide ease of installation as well as a simple setup with reliable operation.

The FP715Si programmer and the two RET2000B-RF wireless room thermostats provide a common timebase for both heating zones. The CET2000B-RF provide wireless hot water thermostat capability.

All Danfoss wireless products use a secure digital radio communication system to ensure reliability and eliminate the possibility of interference with other wireless devices in the home.

This pack is ideal for installations using a vented hot water cylinder where fixed wiring is impractical or undesirable.

Potential savings with chrono-proportional control:

Results based on a high efficiency condensing boiler over a 12 hour period.

63

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

ControlEnergy Saving

(%)

Carbon Sav-ing(%)

Mechanical On/Off - -

Electronic On/Off 2.10 2.31Chrono-Proportional 10.35 10.71

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

LN

LN

Pump

Mains Supply

Boiler

LN

PermLN

Sw.

L

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

LN

N

HP22 . 2-PORT HTG VALVE(Zone 1)

HP22 . 2-PORT HTG VALVE(Zone 2)

HP22 . 2-PORT HW VALVE

NNN

WC4BWiring Centre

Permanent Links

Links to be made by installer

Note: For boilers with pump overrun,please refer to boiler wiring info.

N L 2COM

3ON

4OFF

LN

RX1-S (CET2000B-RF)

N L

L N

N

FP715 Si - Two Channel ProgrammerDHWOFF

HTGOFF

DHWON

HTGON

1 2 3 4

N L 2COM

3ON

4OFF

RX1-S (RET2000B-RF)(Zone 1)

LN

N L 2COM

3ON

4OFF

RX1-S (RET2000B-RF)(Zone 2)

Page 64: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

64

2 x HP22Two port valve

WC4BWiring Centre

2 x RET230PElectronic Room Thermostat

3 Zone PackCommon Heating Times – Unvented System Code Number 087N6500S7

1 x FP715SiTwo channel full programmer

Page 65: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

65

Providing common times for both heating zones and a separate timed hot water zone.

The FP735Si three channel programmer is used to provide time control for the heating and hot water zones.

Dial setting RET230P thermostats provide the customer with a high level of space heating comfort and control accuracy.

Hot water control is achieved using the controls pre-fitted to the unvented hot water cylinder – for wiring and installation details of these please contact the cylinder manufacturer.

This pack is ideal for installations using a standard unvented hot water cylinder.

65

Please Note: To save energy and increase comfort, TRVs should also be fitted on all radiators in rooms without room thermostats.

3 Zone PackCommon Heating Times – Unvented System Code Number 087N6500S7

1 42 3 5 86 7 9 1210 11 13 1614 15

L

N

L N

L N

Pump

Mains Supply

Boiler

LN

PermLN

Sw.

L

COM CALL N

N

RET 230P *Room Thermostat (Zone 2)

Aux. Sw.

OUT INMotorL

N

Brn. Blue Or. Gry

COM

CALL

N N

RET 230P *Room

Thermostat

(Zone 1)Aux. Sw

.

OU

TIN

MotorL

N

Brn.Blue

Or.

Gry

LN

N

HP22 . 2-PO

RT HTG

VALVE

(Zone 1)

HP22 . 2-PORT HTG VALVE(Zone 2)

N

N

L 1 N

L1

WC4BWiring Centre

Permanent Links

Links to be made by installer

Note: For boilers with pump overrun,please refer to boiler wiring info.

N

Link terminals L and COM in the RET 230P for correct operation (see thermostat instructions for further information).

*

L N

N

FP715 Si - Two Channel Programmer ***DHWOFF

HTGOFF

DHWON

HTGON

1 2 3 4

Connected to Unvented Cylinder controls (HW zone valve and required controls are supplied with the Unvented Cylinder).

***

Page 66: Catalogue - Danfoss€¦ · Catalogue Including control packs compliant with 2013 Building Regulations: Part L. Danfoss Limited Ampthill Road Bedford MK42 9ER Reception Tel: 01234

Part No: 021v04 12/15

Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.