catalogue indoor type current transformers cast resin ... · indoor type current transformers cast...

20
Medium Voltage KOFD Indoor Type Current Transformers Cast Resin Insulated 12, 13.8, 17.5, 24 and 36 kV Catalogue KOFD 1 GB 97-12 96-1054

Upload: doanxuyen

Post on 25-Apr-2018

297 views

Category:

Documents


9 download

TRANSCRIPT

Page 1: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

ABB TransmitKOFD 1 GB

1

Medium Voltage

KOFDIndoor Type CurrentTransformersCast Resin Insulated

12, 13.8, 17.5, 24 and 36 kV

Catalogue

KOFD 1 GB 97-12

96-1

054

Page 2: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

KOFD 1 GB

ABB Transmit2

KOFDIndoor Type Current TransformersCast Resin Insulated

12, 13.8, 17.5, 24 and 36 kV

Index

Description ............................................................................................ 3

Technical data and ordering information

— Test voltages ................................................................................. 4

–– Secondary wiring........................................................................... 4

–– Short circuit strength ..................................................................... 4

–– Environment .................................................................................. 5

–– Ordering data ................................................................................ 5

–– Enquiry and order specifications .................................................. 5

–– Order example .............................................................................. 5

–– Use at high altitudes ..................................................................... 6

Dimensions

–– Medium and long size 12–17.5 kV .............................................. 7

–– Medium and long size 24 kV ....................................................... 13

–– Medium size 36 kV ....................................................................... 16

Page 3: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

ABB TransmitKOFD 1 GB

3

KOFD Indoor TypeCurrent TransformersCast Resin Insulated

12, 13.8, 17.5, 24 and 36 kV

Description

The current transformer seriesKOFD is built according the dimen-sion standard DIN 42600, NarrowType. The standard giving dimen-sions for only the herein calledmedium size ABB Transmit also hasdeveloped a longer version to pro-vide more core space. The KOFD-series of transformers covers thecurrent range 15–3000 Amps for12–36 kV. The 13.8 kV and 17.5 kVversions have the same dimensionsas the 12 kV version.

KOFD transformers are available assingle ratio, primary reconnectibledouble ratio and secondary recon-nectible double ratio (or multiratio)types.

96-1

054

Page 4: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

KOFD 1 GB

ABB Transmit4

Indoor Type Current TransformersTechnical data and ordering information

Rated primary currents: Max. 600–1200 A primary reconnectable and3200 A single ratio.Maximum rated continuous thermal current is 3600 A

Secondary current: 5 A, 1 A. Others on request.

Accuracy classes: 0.2, 0.5, 1.0 for measuring5P10, 5P15, 5P20, 10P10, 10P15, 10P20 for protectionOthers on request

Standards: IEC 185, IEC 44-1, VDE 0414. Others on request.

Frequencies: 50 Hz, 60 Hz, others on request

92-1

085

92-1

089

Test voltages

Type KOFD KOFD KOFD KOFD KOFD12 13.8 17.5 24 36kV kV kV kV kV

Highest system voltage 12 13.8 17.5 24 36Power-frequency test, 1 min. 28 34 38 50 70Impulse withstand voltage (peak) 75 95 95 125 170

Short circuit strength

Maximum short circuit values (type tested):

Type Ipn/A Ith Idyn

KOFD 12–24 1250 40 kA 3s, 70 kA 1s 175 kAKOFD 12–24 500–1000 70 kA/1 s 175 kAKOFD 12–24 3200 40 kA 3 s 125 kAKOFD 36 500–1000 31.5 kA 1 s 80 kAKOFD 36 1500 40 kA 3s 175 kA

Secondary wiring

The terminal box is metal with plastic cover and provided with two detachablethreaded inserts, size Pg. 16. Degree of protection is IP 30. The terminals areprovided with M5 screws for the termination of the secondary wiring and withthroughgoing holes for direct earthing of the secondary circuit by M6 screws.6 terminals can be supplied with this construction. Maximum 11 terminals withearthing bridges can be mounted when more than 6 terminals are required. Of these,9 pcs may be used as core secondary terminals. The terminal cover is sealable.

Page 5: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

ABB TransmitKOFD 1 GB

5

Cantilever strength: 5 kN

Environment

The ambient temperature range is from –5 oC to +40 oC (IEC recommendations).The transformers must be protected against unusually heavy deposits of dust orsimilar pollution, as well as against direct sunshine.

Ordering data

For core tables and order information please see separate price list.

Enquiry and order specifications

– Quantity– Type– System voltage– Insulation level– Frequency– Short-time currents Ith (time) and Idyn– Rated primary and secondary currents, extended current rating– Rated burden and accuracy class for each core– Electrical standard– Ambient temperature if other than IEC (–5...+40 oC)– Special requirements, if any (polarity, tropical version, high altitude etc.)– Test report, if required, language specified

Order example

33 pcsKOFD 24C41Un = 20 kV24 / 50 / 125 kV50 Hz25 kA 1s / 63 kA750 / 5 / 5 A, ext. 120 %core 1: cl. 0,5 Fs 10, 10 VAcore 2: cl. 5P10, 5 VAIEC 185Reversed polarity (P2 at the end with the sec. terminals)Test report needed, in english

Indoor Type Current TransformersTechnical data and ordering information

Page 6: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

KOFD 1 GB

ABB Transmit6

Use at high altitudes

In mountaineous areas the height above sea level may be higher than the heightspecified in the IEC standard as design criteria (= 1000 m). The thin air at highaltitudes affects the cooling of the transformers as well as the required creepage &free air distance to earth and between phases. The manufacturer should be con-sulted in such cases.

The problem with creepage and free air distance can be solved by choosing trans-former type designed for higher voltages. The requirement for impulse test voltge(BIL-level) should preferably NOT be higher than normal for the service voltage usedas this may have a negative effect on the available output from the secondaries.

The transformer specification can in such a case be for example:

Type KOFD 24 D2Service voltage 17.5 kVTest voltages 38 kV 1 min. / 95 kV impulse

The transformer type KOFD 17.5 D2 would have been suitable if used below1000 m.

Permissable torques for screw connections

Strenght class for the screws is 8.8. The length of the screw within the nut partshould be at least 1.4 x screw diameter.

Screw Max. torque Min. torqueNm Nm

M5 3.5 2.8

M8 20 16

M12 70 56

Indoor Type Current TransformersTechnical data and ordering information

Page 7: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

ABB TransmitKOFD 1 GB

7

Medium and long size 12–17.5 kVDimensions

Medium sizeIpn < 1250 A

Imax.cont. = 1500 A

Long sizeIpn < 1250 A

Imax.cont. = 1500 A

Type

KOFD 12 A 21 KOFD 13.8 A 21 KOFD 17.5 A 21KOFD 12 C 21 KOFD 13.8 C 21 KOFD 17.5 C 21KOFD 12 E 21 KOFD 13.8 E 21 KOFD 17.5 E 21

Type

KOFD 12 A 41 KOFD 13.8 A 41 KOFD 17.5 A 41KOFD 12 C 41 KOFD 13.8 C 41 KOFD 17.5 C 41KOFD 12 E 41 KOFD 13.8 E 41 KOFD 17.5 E 41KOFD 12 G 41 KOFD 13.8 G 41 KOFD 17.5 G 41

KO

FD

3K

OF

D1

1 If more than 6 secondaryterminals required (max. 11)

1 If more than 6 secondaryterminals required (max. 11)

Weight ~ 20 kg

Weight ~ 31 kg

2 6 0

4 1 7 0 1 5 0

2 25

220

20

3 4 5

2 7 01 3 5 M 1 2

1 5 1 2 0 3 2

11 125

148

M 8

P g 1 6 , P r 2 2 , 5 1 0 4

K P1

L P2

1

3 8 0

4 1 7 0

2 25

220

20

P g 1 6 /P R 2 2 , 5 1 0 4

4 6 5

3 9 0

M 1 21 3 5

11

1 5 1 2 0 3 2

125

148

M 8

K P1

L P2

1

Page 8: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

KOFD 1 GB

ABB Transmit8

Medium and long size 12–17.5 kVDimensions

Medium sizeIpn < 600–1200 A

Imax.cont. = 1200 A

Long sizeIpn < 600–1200 A

Imax.cont. = 1200 A

Type

KOFD 12 B 21 KOFD 13.8 B 21 KOFD 17.5 B 21KOFD 12 D 21 KOFD 13.8 D 21 KOFD 17.5 D 21KOFD 12 F 21 KOFD 13.8 F 21 KOFD 17.5 F 21

Type

KOFD 12 B 41 KOFD 13.8 B 41 KOFD 17.5 B 41KOFD 12 D 41 KOFD 13.8 D 41 KOFD 17.5 D 41KOFD 12 F 41 KOFD 13.8 F 41 KOFD 17.5 F 41KOFD 12 H 41 KOFD 13.8 H 41 KOFD 17.5 H 41

KO

FD

4K

OF

D2

1 If more than 6 secondaryterminals required (max. 11)

1 If more than 6 secondaryterminals required (max. 11)

Weight ~ 20 kg

Weight ~ 31 kg

3 8 0

4

1 7 0 2 7 0

2 25

220

20

1 0 4P k 1 6 , P g 1 6P g 1 6 / P r 2 2 , 5

11

4 6 53 9 0

1 3 5 M 1 2

1 5 1 2 0 3 2

M 8

125

148P

1Ka

C1

Kb

C2

La

P2

Lb

1

11

1 5 1 2 0 3 2

3 4 5

2 7 0

1 3 5 M 1 2

125

148

M 8

P1

Ka

C1

C2

P2

LbLa

Kb

4

1 7 0 1 5 0

20

220

2 6 0

2 25

1 0 4P k 1 6 , P g 1 6P g 1 6 / P r 2 2 , 5

1

Page 9: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

ABB TransmitKOFD 1 GB

9

Medium and long size 12–17.5 kVWide bodyDimensions

Medium sizeWide body

Ipn < 1250 A

Imax.cont. = 1500 A

Long sizeWide body

Ipn < 1250 A

Imax.cont. = 1500 A

Type

KOFD 12 AA 21 KOFD 13.8 AA 21 KOFD 17.5 AA 21KOFD 12 CA 21 KOFD 13.8 CA 21 KOFD 17.5 CA 21KOFD 12 EA 21 KOFD 13.8 EA 21 KOFD 17.5 EA 21

Type

KOFD 12 AA 41 KOFD 13.8 AA 41 KOFD 17.5 AA 41KOFD 12 CA 41 KOFD 13.8 CA 41 KOFD 17.5 CA 41KOFD 12 EA 41 KOFD 13.8 EA 41 KOFD 17.5 EA 41KOFD 12 GA 41 KOFD 13.8 GA 41 KOFD 17.5 GA 41

KO

FD

7K

OF

D15

1 If more than 6 secondaryterminals required (max. 11)

Weight ~ 40 kg

Weight ~ 29 kg

1 If more than 6 secondaryterminals required (max. 11)

3 4 5

1 2 5

1 6 5 2 7 21 9 0

4 6 2

2

25

20

220

1 0 4P g 1 6

3 9 0

1 3 5 M 1 2M 8

12

1 5 1 2 0 3 2

160

184

40

K P1

L P2

P2

P1

K L

80

40

3 2 1 2 0

O n r e q u e s t

1

2 5 0

1 6 5 1 5 0

3 4 0

2

25

220

20

P g 1 6 1 0 4

2 7 0

M 1 21 3 5

M 8

12

1 5 1 2 0 3 2

40

160

184

K

80

40

3 2 1 2 0

LK

P2P1

O n r e q u e s t

P1

L P2

1

Page 10: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

KOFD 1 GB

ABB Transmit10

Medium and long size 12–17.5 kVWide bodyDimensions

Medium sizeWide body

Ipn < 600–1200A

Imax.cont. = 1200 A

Long sizeWide body

Ipn < 600–1200A

Imax.cont. = 1200 A

Type

KOFD 12 BA 21 KOFD 13.8 BA 21 KOFD 17.5 BA 21KOFD 12 DA 21 KOFD 13.8 DA 21 KOFD 17.5 DA 21KOFD 12 FA 21 KOFD 13.8 FA 21 KOFD 17.5 FA 21

Type

KOFD 12 BA 41 KOFD 13.8 BA 41 KOFD 17.5 BA 41KOFD 12 DA 41 KOFD 13.8 DA 41 KOFD 17.5 DA 41KOFD 12 FA 41 KOFD 13.8 FA 41 KOFD 17.5 FA 41KOFD 12 HA 41 KOFD 13.8 HA 41 KOFD 17.5 HA 41

KO

FD

8K

OF

D16

1 If more than 6 secondaryterminals required (max. 11)

Weight ~ 40 kg

Weight ~ 29 kg

1 If more than 6 secondaryterminals required (max. 11)

3 4 5

1 2 5

1

1 6 5 2 7 21 9 0

4 6 2

2

220

20

25

P g 1 6 1 0 4

3 9 0

1 3 5

12

160

184

40

M 8

1 5 1 2 0 3 2

M 1 2

P1

Ka

C1

C2

P2

LbLa

Kb

1

2 5 0

2 25

220

20

1 0 4P g 1 61 6 5 1 5 0

3 4 0

12

2 7 0

1 3 5 M 1 2

M 8

40

160

184

1 5 1 2 0 3 2

P1

C1

C2

P2

Ka

Kb

La Lb

Page 11: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

ABB TransmitKOFD 1 GB

11

Medium and long size 12–17.5 kVDimensions

Long sizeIpn < 3200 A

Imax.cont. = 3200 A

Medium sizeIpn < 3200 A

Imax.cont. = 3200 A

1 If more than 6 secondaryterminals required (max. 11)

Weight ~ 26 kg

1 If more than 6 secondaryterminals required (max. 11)

Weight ~ 37 kg

KO

FD

5K

OF

D6

2 6 0

4 1 7 0 1 5 0

20

220

2 25

1 0 4P g 1 6 /P r . 2 2 , 5

3 4 5

2 7 0

1 3 5 M 1 2

11

1 5 1 2 0 3 2

40 80

125

148

M 8P1

P2

LK

1

3 8 0

4 1 7 0 2 7 0

220

20

2 25

1 0 4P g 1 6 /P r . 2 2 , 5

4 6 53 9 0

M 1 21 3 5

11

1 5 1 2 0 3 2

M 8

80

125

148

40P

1K L

P2

1

Type

KOFD 12 P 21 KOFD 13.8 P 21 KOFD 17.5 P 21KOFD 12 R 21 KOFD 13.8 R 21 KOFD 17.5 R 21KOFD 12 S 21 KOFD 13.8 S 21 KOFD 17.5 S 21

Type

KOFD 12 P 41 KOFD 13.8 P 41 KOFD 17.5 P 41KOFD 12 R 41 KOFD 13.8 R 41 KOFD 17.5 R 41KOFD 12 S 41 KOFD 13.8 S 41 KOFD 17.5 S 41KOFD 12 T 41 KOFD 13.8 T 41 KOFD 17.5 T 41

Page 12: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

KOFD 1 GB

ABB Transmit12

Medium sizeWide bodyIpn < 3200 A

Imax.cont. = 3600 A

Long sizeWide bodyIpn < 3200A

Imax.cont. = 3600A

Type

KOFD 12 K 21 KOFD 13.8 K 21 KOFD 17.5 K 21KOFD 12 L 21 KOFD 13.8 L 21 KOFD 17.5 L 21KOFD 12 M 21 KOFD 13.8 M 21 KOFD 17.5 M 21

Type

KOFD 12 K 41 KOFD 13.8 K 41 KOFD 17.5 K 41KOFD 12 L 41 KOFD 13.8 L 41 KOFD 17.5 L 41KOFD 12 M 41 KOFD 13.8 M 41 KOFD 17.5 M 41KOFD 12 N 41 KOFD 13.8 N 41 KOFD 17.5 N 41

KO

FD

64K

OF

D65

Weight ~ 30 kg

Weight ~ 41 kg

1 If more than 6 secondaryterminals required (max. 11)

1 If more than 6 secondaryterminals required (max. 11)

Medium and long size 12–17.5 kVWide bodyDimensions

3 4 51 2 5

1 6 5

1 9 04 6 2

2 7 2

2

220

20

1 0 4P g 1 6

3 9 0

1 3 5

12

1 5 1 2 0 3 2

40 80

160

184

M 1 2 x 2 5

M 8

P2

P1

KL

1

2 5 0

1 6 5 1 5 0

3 4 0

2

220

20

1 0 4P g 1 6

2 7 0

1 3 5

12

1 5 1 2 0 3 2

40 80

160

184

M 8

M 1 2 x 2 5 t i e f

P2 P1

KL

1

Page 13: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

ABB TransmitKOFD 1 GB

13

Medium sizeIpn < 1250 A

Imax.cont. = 1500 A

Medium and long size 24 kVDimensions

Long sizeIpn < 1250 A

Imax.cont. = 1500 A

Type

KOFD 24 A 21KOFD 24 C 21KOFD 24 E 21

KO

FD

11K

OF

D9

1 If more than 6 secondaryterminals required (max. 11)

Type

KOFD 24 A 41KOFD 24 E 41KOFD 24 C 41KOFD 24 G 41

Weight ~ 42 kg

1 If more than 6 secondaryterminals required (max. 11)

Weight ~ 29 kg

3 4 5

2 25

1

4 1 6 5 2 5 0

20

280

1 0 4P k 1 6 , P g 1 6

P g 1 6 / P r 2 2 , 5

14

4 4 03 7 5

1 4 0 M 1 2

1 9 1 2 0 3 2

M 8

150

178K P

1 L P2

2 5 0

2 25

4 1 6 5 1 5 5

20

280

1 0 4P g 1 6 /P r . 2 2 , 5

3 4 52 8 0

1 4 0 M 1 2M 8

14

1 9 1 2 0 3 2

150

178

K P1

L P2

1

Page 14: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

KOFD 1 GB

ABB Transmit14

Medium sizeIpn < 600–1200A

Imax.cont. = 1200 A

Medium and long size 24 kVDimensions

Long sizeIpn < 600–1200 A

Imax.cont. = 1500 A

Type

KOFD 24 B 21KOFD 24 D 21KOFD 24 F 21

KO

FD

12K

OF

D10

1 If more than 6 secondaryterminals required (max. 11)

Type

KOFD 24 B 41KOFD 24 D 41KOFD 24 F 41KOFD 24 H 41

Weight ~ 42 kg

1 If more than 6 secondaryterminals required (max. 11)

Weight ~ 29 kg

4 4 03 7 5

1 4 0 M 1 2

3 4 5

4 1 6 5 2 5 0

2 2528

020

1 0 4P k 1 6 , P g 1 6

P g 1 6 / P r 2 2 , 5

M 8

1 2 0 3 2

150

178

14

1 9

P1

Ka

C1

C2

P2

Kb

La Lb

1

2 5 0

280

20

1 6 5 1 5 5

2 5

4

2

1 0 4P k 1 6 , P g 1 6P g 1 6 / P r 2 2 , 5

14

1 9 1 2 0 3 2

M 8

3 4 52 8 0

1 4 0 M 1 2

150

178P

1Ka

C1

C2

P2

LbLaKb

1

Page 15: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

ABB TransmitKOFD 1 GB

15

Medium and long size 24 kVDimensions

Medium sizeIpn < 3200 A

Imax.cont. = 3600 A

Long sizeIpn > 3200 A

Imax.cont. = 3600 A

KO

FD

13K

OF

D14

Type

KOFD 24 K 21KOFD 24 L 21KOFD 24 M 21

Type

KOFD 24 K 41KOFD 24 L 41KOFD 24 M 41KOFD 24 N 41

Weight ~ 46 kg

Weight ~ 33 kg

1 If more than 6 secondaryterminals required (max. 11)

1 If more than 6 secondaryterminals required (max. 11)

3 4 5

2 2528

020

2 5 01 6 5

1

4

4 4 01 0 4

P g 1 6 /P r 2 2 . 5

3 7 5

1 4 0 M 1 2 M 8

14 1 9 1 2 0 3 2

40 80 150

178P1

K LP2

2 5 0

2 25

4 1 6 5 1 5 5

3 4 5

280

20

1 0 4P g 1 6 /P r . 2 2 , 5

2 8 0

1 4 0 M 1 2M 8

14

1 9 1 2 0 3 2

40 80

150

178P

1 P2

LK

1

Page 16: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

KOFD 1 GB

ABB Transmit16

Medium size 36 kVDimensions

Narrow bodyIpn < 1250 A

Imax.cont. = 1500 A

Type

KOFD 36 AA 41KOFD 36 CA 41KOFD 36 EA 41KOFD 36 GA 41

KO

FD

18

Type

KOFD 36 A 41KOFD 36 C 41KOFD 36 E 41KOFD 36 G 41

Wide bodyIpn < 1250 A

Imax.cont. = 1500 A

KO

FD

20

Weight ~ 72 kg

Weight ~ 52 kg

1 If more than 6 secondaryterminals required (max. 15)

1 If more than 6 secondaryterminals required (max. 15)

14

1 9 2 2 0 3 2

40

225

249

K P1

P2

L

3 4 3

225

390

20

1

2 1 1 1 7 1 , 5

M 8

405

P k 1 6 1 0 5

4 1 03 0 0

1 5 0 M 1 2

3 4 3

225

390

2 1 1 1 7 1 , 5M 8

1

405

P k 1 6 1 0 5

4 1 0

3 0 0

1 5 0 M 1 2

14

1 9 2 2 0 3 2

40

225

249

K P1

P2

L

20

Page 17: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

ABB TransmitKOFD 1 GB

17

Medium size 36 kVDimensions

Narrow bodyIpn < 600–1200 A

Imax.cont. = 1200 A

Type

KOFD 36 BA 41KOFD 36 DA 41KOFD 36 FA 41KOFD 36 HA 41

KO

FD

19

Type

KOFD 36 B 41KOFD 36 D 41KOFD 36 F 41KOFD 36 H 41

Wide bodyIpn < 600–1200 A

Imax.cont. = 1200 A

KO

FD

21

Weight ~ 72 kg

Weight ~ 52 kg

1 If more than 6 secondaryterminals required (max. 15)

1 If more than 6 secondaryterminals required (max. 15)

1

4 1 0

3 0 0

1 5 0 M 1 2

1 9 2 2 0 3 2

40

225

249

14

P1

Ka

C1

C2

Kb

La

Pa

Lb

2 1 1 1 7 1 , 5

20

M 8

390

3 4 3

225

408

P k 1 6 1 0 5

3 4 3

225

390

408

1

2 1 1 1 7 1 , 5

20

M 8

4 1 03 0 0

1 5 0 M 1 2

14

1 9 2 2 0 3 2

40

225

249

P1

Ka

C1

C2

Kb La

P2

Lb

1 0 5P k 1 6

Page 18: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

KOFD 1 GB

ABB Transmit18

Medium size36 kVDimensions

Medium sizeWide bodyIpn < 3000 A

Imax.cont. = 3000 A

KO

FD

22

Type

KOFD 36 K 41KOFD 36 L 41KOFD 36 M 41KOFD 36 N 41

1 If more than 6 secondaryterminals required (max. 15)

Weight ~ 72 kg

3 4 3

2

390

20

M 8

7 0

3 22 2 0

1 9

14

4 1 03 0 0

1 5 0 M 1 2

P1

K LP2

40 80

225

249

405

P k 1 6 1 0 5

1

2 1 1 1 7 1 , 5

25

Page 19: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

ABB TransmitKOFD 1 GB

19

Page 20: Catalogue Indoor Type Current Transformers Cast Resin ... · Indoor Type Current Transformers Cast Resin Insulated 12, ... Current Transformers Cast Resin Insulated 12, 13.8, 17.5,

KOFD 1 GB

ABB Transmit20

ABB Transmit OyMV Systems DivisionInstrument TransformersP.O. Box 613, FIN-65101 Vaasa, FinlandPhone +358 10 22 4000Telefax +358 10 22 42616

KO

FD

1 G

B 9

7-12

Waa

sa G

raph

ics

Oy

3000

, 97

-12