catalogue no: vs800ge3800 t2 mccb 1000v ac 30ka 3p 800a

3
Power Distribution and Protection > Circuit Breakers > Moulded Case Circuit Breakers > TemBreak Mining MCCB > TemBreak Mining 800 AF > Electronic 800 AF 30 kA T2 MCCB 1000V AC 30kA 3P 800A ELECTRONIC VS800GE3800 Catalogue No: · 1000 VAC MCCB for power distribution and motor starting use in mines or tunnels · Current limiting device, reduces fault let through energy for increased installation safety · Direct opening and indication of main contact status – maximising machine and user safety · Complies to AS / NZS 60947-2, IEC 60947-2 and CE · Panel mount standard, with other mounting options · Full range of accessories for application flexibility · 3 pole MCCB · 370 mm (H), 120 mm (D), 70 mm pole centres · Fault interruption rating; 30 kA Icu @ 1000 VAC · Utilisation voltage ratings 1000 or 1100 VAC · 2 dial electronic trip unit: 7 preset characteristic curve selection dial and base current adjustment dial · Options include GF or PTA · Trip units; 800 A Representative Photo Only (actual product may vary based on configuration selections) T2 MCCB 1000V AC 30kA 3P 800A ELECTRONIC SPECIFICATIONS Switching Poles Utilisation Category Type of Power Supply Component Type MCCB Model Poles Frame Size Rated Frequency Connection Mode Suitable for Distribution Switchboard or MCC Trip Unit Rating Trip Unit Protection Type Ue, Rated Operational Voltage, AC, max Un, Nominal Operational Voltage, AC Uimp, Impulse Withstand Voltage Ui, Rated Insulation Voltage In, Rated Current at 30°C In, Rated Current at 35°C In, Rated Current at 40°C In, Rated Current at 45°C In, Rated Current at 50°C In, Rated Current at 55°C In, Rated Current at 60°C In, Rated Current at 65°C In, Rated Current at 70°C 3P A AC AC/DC MCCB AC VS 3P 800 AF size 50 / 60 Hz Extension Bar (Option) Front Connection Plug-in Base (Option) Rear Connection (Option) Yes 800 A Electronic LSI 1100 V AC 1000 V AC 8 kV 1100 V (rms) 800 A @30°C 800 A @35°C 800 A @40°C 800 A @45°C 800 A @50°C 758 A @55°C 737 A @60°C 716 A @65°C 400 A @70°C Page 1 of 3 18 September 2021, 1300 NHP NHP | nhp.com.au | 0800 NHP NHP | nhp-nz.com VS800GE3800 Datasheet NHP Electrical Engineering Products

Upload: others

Post on 22-Mar-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

Power Distribution and Protection > Circuit Breakers > Moulded Case Circuit Breakers > TemBreak Mining MCCB >TemBreak Mining 800 AF > Electronic 800 AF 30 kA

T2 MCCB 1000V AC 30kA 3P 800A ELECTRONIC

VS800GE3800Catalogue No:

· 1000 VAC MCCB for power distribution and motor starting use in mines or tunnels

· Current limiting device, reduces fault let through energy for increased installation safety

· Direct opening and indication of main contact status – maximising machine and user safety

· Complies to AS / NZS 60947-2, IEC 60947-2 and CE· Panel mount standard, with other mounting options· Full range of accessories for application flexibility· 3 pole MCCB· 370 mm (H), 120 mm (D), 70 mm pole centres· Fault interruption rating; 30 kA Icu @ 1000 VAC· Utilisation voltage ratings 1000 or 1100 VAC· 2 dial electronic trip unit: 7 preset characteristic curve

selection dial and base current adjustment dial· Options include GF or PTA· Trip units; 800 A

Representative Photo Only(actual product may vary based on configuration selections)

T2 MCCB 1000V AC 30kA 3P 800A ELECTRONIC

SPECIFICATIONS

Switching Poles

Utilisation Category

Type of Power Supply

Component Type MCCB

Model

Poles

Frame Size

Rated Frequency

Connection Mode

Suitable for Distribution Switchboard or MCC

Trip Unit Rating

Trip Unit Protection Type

Ue, Rated Operational Voltage, AC, max

Un, Nominal Operational Voltage, AC

Uimp, Impulse Withstand Voltage

Ui, Rated Insulation Voltage

In, Rated Current at 30°C

In, Rated Current at 35°C

In, Rated Current at 40°C

In, Rated Current at 45°C

In, Rated Current at 50°C

In, Rated Current at 55°C

In, Rated Current at 60°C

In, Rated Current at 65°C

In, Rated Current at 70°C

3P

A

AC AC/DC

MCCB AC

VS

3P

800 AF size

50 / 60 Hz

Extension Bar (Option)Front ConnectionPlug-in Base (Option)Rear Connection (Option)

Yes

800 A

Electronic LSI

1100 V AC

1000 V AC

8 kV

1100 V (rms)

800 A @30°C

800 A @35°C

800 A @40°C

800 A @45°C

800 A @50°C

758 A @55°C

737 A @60°C

716 A @65°C

400 A @70°C

Page 1 of 318 September 2021,1300 NHP NHP | nhp.com.au | 0800 NHP NHP | nhp-nz.com

VS800GE3800 DatasheetNHP Electrical Engineering Products

Power Distribution and Protection > Circuit Breakers > Moulded Case Circuit Breakers > TemBreak Mining MCCB >TemBreak Mining 800 AF > Electronic 800 AF 30 kA

T2 MCCB 1000V AC 30kA 3P 800A ELECTRONIC

VS800GE3800Catalogue No:

Ics, Rated Service Short-Circuit Breaking Capacity, 1000VAC

Icu, Rated Ultimate Short-Circuit Breaking Capacity, 1000VAC

Icu, Rated Ultimate Short-Circuit Breaking Capacity, 1100VAC

AC Power loss per pole at full rated current

Number of Poles

Depth (toggle included)

Height

Width

Depth

Weight

Dielectric Strength

Electrical Life

Mechanical Life

Altitude, Operating (No Derating)

Terminal Type

Tightening Torque, Min

Tightening Torque, Max

Pollution Degree

DIN rail mounting with optional adapter

Suitable for Panel Mounting

Suitable for Mounting on Chassis

Withdrawable

Standards Compliance

Rated temperature of trip unit

Storage Temperature, Min

Storage Temperature, Max

Operating Temperature, Min

Operating Temperature, Max

Relative Humidity, Max

Thermal Trip Type

Ir, Thermal Trip Current, Min

Ir, Thermal Trip Current, Max

Im, Magnetic Trip Current

General Accessories

Terminal Bar Connection

Vibration Acceleration (Max.)

Vibration Frequency, Operational (Max.)

Vibration Duration (Max.)

Certifications

Shipping Approvals

20 kA

30 kA @1kVAC

30 kA @1.1kVAC

81.66 W

3

171 mm

370 mm

210 mm

120 mm

19.8 kg

3500 V AC

500 cycles

5000 cycles

2000 m

Extension Bar With Bolt holes

40.2 Nm

65.7 Nm

3

No

Yes

No

No

AS/NZS 60947-2IEC 60947-2

45 °C

-10 °C min

70 °C max

-5 °C min

70 °C max

85 %RH

Adjustable type

320 A

800 A

0 A

Alarm SwitchAuxiliary SwitchesExternal Panel DisplayHandle OperatorsInterpole BarriersLocking DevicesMechanical InterlockMotor OperatorShunt TripTerminal CoversUnder Voltage Trip

Cable or Busbar

19 m/s²

16.7 Hz

12 min

CERCM

Contact NHP

Page 2 of 318 September 2021,1300 NHP NHP | nhp.com.au | 0800 NHP NHP | nhp-nz.com

VS800GE3800 DatasheetNHP Electrical Engineering Products

Power Distribution and Protection > Circuit Breakers > Moulded Case Circuit Breakers > TemBreak Mining MCCB >TemBreak Mining 800 AF > Electronic 800 AF 30 kA

T2 MCCB 1000V AC 30kA 3P 800A ELECTRONIC

VS800GE3800Catalogue No:

REFERENCES

Installation Guide: -

User Manual: -

Manufacturer Datasheet: -

Manufacturer Catalogue& Product Selection:

-

Supplier Declaration ofConformity:

-

IECEx Certificate -

Dimension Diagram

Page 3 of 318 September 2021,1300 NHP NHP | nhp.com.au | 0800 NHP NHP | nhp-nz.com

VS800GE3800 DatasheetNHP Electrical Engineering Products