cedarbrook)sauna)+ steam – …cedarbrooksauna.com/manuals/sauna-heater-manuals/scandia... ·...
TRANSCRIPT
Cedarbrook Sauna + Steam – Family owned and operated since 1971
We build cedar saunas , kits, sauna doors , accessories for commercial saunas & residential sauna rooms — AND we have the expertise to fit you with the right sauna heaters , steam room doors and steam room equipment.
If you are ever in the Seattle area, we have a showroom just northeast of the city where you'll find sauna and steam rooms plus accessories on display.
If you have any questions regarding saunas and steam rooms, we’re your resource!
Sweating the details since 1971
Brekke LysakerManagement
r friendly staff is ready to answer your questions on what we do best : building and designing sauna rooms and doors, selecting the sauna heater that best fits your needs and answering any other questions regarding sauna and steam rooms.
Ou
1
Heater Model __________ Serial # __________
ULTRA-SAUNA HEATER Proudly made in USA since 1964
LARGE HEATERS 12.0-18.0 KW
Installation Instructions & User Manual
I n s t a l l a t i o n G u i d e
PO Box 636 Eagle Idaho USA. 83616 T: 877.467.2862 F: 208.286.0290 [email protected] www.scandiamfg.com
2
Sauna room should be vented according to manufacturer’s specifications or Scandia sauna room specification found in the Scandia sauna installation instructions. Improper ventilation is dangerous
for the sauna user’s health. When the door is under cut, there is no other venting required in small
sauna rooms. You should have between 3/4” to 1” between the finished floor and the bottom of the
door. If further venting is preferred or required, the inlet vent should be below the heater, or near the
base of the heater. Outlet vent can be on the opposite wall of the heater under the top bench.
SAUNA ROOM VENTING GUIDELINES
BEFORE YOU START
YOUR HEATER SHOULD INCLUDE
Controls Main Heater Unit Sauna Rocks Thermostat sensor wall cover (not included with T-model heaters) Installation Instructions Warning Sign
Ultra Sauna Heaters—Large (26” W x 18” D x 29” H) Model Watts Volts Phase Amps Max Room Size
12240 12000 240 1 50 140 sq ft (44 sq m)
12240-3 12000 240 3 29 140 sq ft (44 sq m)
12208 12000 208 1 57.7 140 sq ft (44 sq m)
12208-3 12000 208 3 33.3 140 sq ft (44 sq m)
15240 15000 240 1 62.5 205 sq ft (63 sq m)
15240-3 15000 240 3 36.2 205 sq ft (63 sq m)
15208 15000 208 1 72.2 205 sq ft (63 sq m)
15208-3 15000 208 3 41.7 205 sq ft (63 sq m)
18240 18000 240 1 75 240 sq ft (73 sq m)
18240-3 18000 240 3 43.3 240 sq ft (73 sq m)
18208 18000 208 1 86.6 240 sq ft (73 sq m)
18208-3 18000 208 3 50 240 sq ft (73 sq m)
18480-3 18000 480 3 22 240 sq ft (73 sq m)
HEATER SIZING
Heater and controls must be installed by a licensed electrician Heater must be installed according to local codes. Ensure all factory connections are tight. Wires may have come loose in shipping. Plastic must be removed from shell before operating heater. Sauna door must always open outward. Sauna door can never include a lock.
3
SAUNA HEATER GUARD RAIL PLACEMENT GUIDE
CONTROL PANEL MODELS AND SIZES
CONTROL PANEL LOCATION All controls must be mounted on the outside of the sauna, NEVER inside the room.
RESIDENTIAL INSTALLATION – For convenience, place the control box at eye level by the door, approximately 12” from the door opening and 52” from the floor(see fig. 1). For conduit and wire size, type and quantities, see specific heater wiring diagram charts. COMMERCIAL INSTALLATION – for 60-min timer, follow the residential installation recom-mendations. For 24-hour timer, you may place the control panel either in front of the sauna or in the mechanical or electrical room away from the sauna room. Please note that the thermo-stat capillary tube is only 4 ft long, therefore for controls placed away from the sauna, we rec-ommend T-model heaters, where the thermostat is built in the heater itself.
52"
12"
Do
or o
pen
s on
the
rig
ht
Sauna exterior wall
Minimum dimensions of heater guard must be 42” L x 26” d x 39” H—Top rail of guard must be below heater vent
A
J
ToCeiling(H-7ft)
C
Towall
or guardrail
G
I
D
H
HC
L
B
F
A/B Control Rough -In Dimensions
8 ¼”
12 ¼”
4"
14 ¼”
9 ¾”
0
1545
30
Control Cover Plate Control Box
22 ga Brushed AluminumI8 ga Galvanized
Paint -loc Steel* NOTE: rough-in ½” extra on box dimensions
A/B control: suitable for heater models 75240, 75208, 90240, 90208, 12208-3 (standard or T-model heaters)
15 ½”
13 ¼”
0
1545
30
Control Cover Plate Control Box
22 ga Brushed AluminumI8 ga Galvanized
Paint-loc Steel
E/E24 Control Rough -In Dimensions
* NOTE: rough-in ½” extra on box dimensions
12 ¼”
14"
4"
E control: suitable for heater models 12240, 12208, 15240, 15208, 18240, 18208, 18480 (standard or T-model
Description 12KW‐18KW
A Width Of Heater Shell 26"
B Wall to Face of Heater 18"
C Side of Heater to Wall (Min.) 8"
D Height of Heater Shell 29"
E Wall to Inside of Guard (Min.) 26"
F Lower to Upper Mounting 28"
G F.F. to Bottom Mount 10 3/4"
H Heater Center to Wall (Min.) 22"
I F.F. to Bottom of Heater 10"
J Top of Heater to Ceiling (7ft.) 39"
4
Line feeds /ground from C ontro l box to H eater
H eater
C o n tro ls b e h in d co ve r
(2 4 ho u r tim er)
Line Feeds /G round F rom Break er
IM P O R T A NT N O TE S:
- H eater mus t be ins talled by a lic ens ed elec tric ian .- H eater mus t be ins talled ins ide the s auna room and m ounted one foot f rom the f loor .- C ontrols m us t be ins ta lled outs ide of the s auna room . - T herm os tat c apillary s ens or bu lb m us t be loc ated ins ide the s auna room (horiz ontal pos it ion ) approx . 10 inc hes f rom c eiling. - A ll w iring m us t c om ply w ith Loc al and S tate ordinanc es : a ll w iring into the s auna room m us t be ra ted for at leas t 90 degrees C els ius (194 deg F arenhiet ). - S tandard s auna c eiling height is 7 feet . - C ons ult all loc al c odes before ins ta lla t ion . - W arning signs m us t be ins talled at ey e lev el on door and abov e heater . - D oor m ust a lw ay s s w ing outw ard .- A ir in tak e v ent m us t be ins talled below heater and an air ex haus t v ent s hould be ins talled .- T herm os tat s hould be plac ed behind c ov er and out of c ontrol of gues ts /mem bers . S ett ing s hould be no h igher than 180 degrees farenheit (85 C elc ius)
O pt ion #1C ontrols near door
C o n tro ls (2 4 ho u r
tim er)
Line F eeds /G round F rom Break er
Line feeds /ground from C ontrol box to H eater
O pt ion #2C ontrols in rem ote loc at ion
Control panel on the outside of sauna room. Recessed mounted.
Wall mounted
inside sauna room
10-12”
Recommended grill vent below heater improves efficiency of heater.
Line feeds/ground from C ontrol box to H eater
Heater
ControlBox
Line Feeds /Ground From Breaker
Thermostat Sensor Bulb
W arningSigns
Thermostat sensor bulb must be mounted inside the sauna 10” from ceiling—horizontal position. Use supplied bracket to hold it in place.
Wall mounted
inside sauna room
Control panel on the outside of sauna room. Recessed mounted.
10-12”
View from outside of sauna Recommended grill vent below heater im-proves efficiency of heater.
60-min timer
24-hour timer
Important: For controls in remote locations, T-model heater is recommended, please ask your Scandia sales representative.
STANDARD HEATER / CONTROL CONFIGURATION
Note: All Ultra-Sauna heaters can be ordered as T-model from factory. T-model heaters have the thermostat built in the heater, eliminating the need to have the thermostat sensor in the wall.
10-12”
5
Series Watts Volts Amps Phase Mas Room Size Circuit Breaker Supply Wires (incl ground) Wires from control to heater
90-3 9000 240 / 208 21.7 / 25 3 80 sq ft 60 4 qty #8 ga 4 qty #8 ga - 2 qty #14
120-3 12000 240 / 208 29 / 33.4 3 120 sq ft 40 4 qty #8 ga 4 qty #8 ga - 2 qty #14
A3 Controls (60 minute timer) 9000 Watts to 12000 Watts Hea ters Three-phase only 240/208 Volts
GroundThree Phase Power Feed
C ontac to r
Con tact or
1 2 3
Control Box Sauna H eater
High L imit S witc h
Ground Terminal
Scandi a el ectri c heaters
are UL l is ted
1 2 3To High
Lim it
Element 1Element 2
Element 3
5421
3 6
1 2
To contactor
coils
To contactor
coils
Timer
T -stat
A3
cont
rol
WIRING DIAGRAMS
Series Watts Volts Amps Phase Mas Room Size Circuit Breaker Supply Wires (incl ground) Wires from control to heater
90-3 9000 240 / 208 21.7 / 25 3 80 sq ft 60 4 qty #8 ga 4 qty #8 ga - 2 qty #14
120-3 12000 240 / 208 29 / 33.4 3 120 sq ft 40 4 qty #8 ga 4 qty #8 ga - 2 qty #14
A3 Controls (60 minute timer) 9000 Watts to 12000 Watts Heaters Three-phase only 240/208 Volts
GroundThree Phase Power Feed
C ontac tor
Contactor
1 2 3
Control Box Sauna H eater
High L imit S witc h
Ground Terminal
Scandia el ectri c heaters
are UL l isted
1 2 3To High
Limit
Element 1Element 2
Element 3
5421
3 6
1 2
To contactor
coils
To contactor
coils
Timer
T -stat
Sauna H eater
High L imit S witc h
Ground Terminal
Scandia el ectri c heaters
are UL l isted
Element 1Element 2
Element 3
5421
3 6
Ground
C ontac tor
Contactor
1 2 3
Control Box
1 2 3
o actor ls
To contactor
coils
Sauna Heater
Thre e Phase Power Feed
C
C
1To High
Lim it
1 2
To contactor
coilsTimer
T -stat
1 2
T -stat High L imit Switc h
40
50
B3
cont
rol
B3
6
E2
cont
rol
G ro u n dS i n g le P h a s e
T o E le m e n t s
C o n t a c t o r
C o n t a c t o r
C o n t a c t o r
C o n t a c t o r
1 2 3 4 5 6
T 1 T 2
L 2L 1
1 2
C o n tr o l B o x
1 2 3 4 5 6
S a u n a H e a te r
E le m e n t 1E le m e n t 2
E le m e n t 3
65
4
32
1
T o H i g h L i m i t
T o H i g h L im i t
H i g h L i m it S w it c h
G ro u n d T e r m in a l
F u s eA s s e m b l ie s
S c a n d ia e le c t r ic h e a t e r s
a re U L l i s t e d
T o c o n t a c t o r c o i ls
T o c o n t a c t o r c o il s
E 2 C o n t r o l f o r S c a n d i a / V i c o 1 2 K W , 1 5 K W a n d 1 8 K W H e a te r 2 0 8 V a n d 2 4 0 V (S i n g l e P h a s e C o n f i g u r a t i o n )
S eries W a tts V o lts A m ps P hase M as R oom S ize C ircu it B reake r S upp ly W ires (inc l g round) W ires from con tro l to hea te r
120 12000 240 / 208 50 /57 .7 1 120 sq ft 60 /70 (240V , 3q ty #6 ) 208V , 3q ty #4 ) 7 q ty #10 ga - 2 q ty #14
150 15000 240 / 208 62 .5 / 72 .2 1 180 sq ft 70 /90 (240V , 3q ty #4 ) 208V , 3q ty #2 ) 7 q ty #10 ga - 2 q ty #14
Watts Voltage Amps Phase Max Room Size Circuit Breaker Supply Wires (Inc.Ground) Wires (Control to Heater)
12000 240/208 50 / 57.7 1 120 sq ft 60 / 70 240 3 #6 / 208 3 #4 7 qty #10 ‐ 2 qty #14
15000 240/208 62.5 / 72.2 1 180 sq ft 70 / 90 240 3 #4 / 208 3 #2 7 qty #10 ‐ 2 qty #14
18000 240/208 75 / 86.6 1 240 sq ft 90 / 100 3 qty #2 7 qty #10 ‐ 2 qty #14
E2 Controls (60 minute timer) 12000‐18000 Watt 240/208 Volt single phase
WIRING DIAGRAMS
G ro u n dT h r e e P h a se P o w e r F e e d
To E le m e n ts
C o n ta c to r
C o n ta ct o r
C o n ta c to r
C o n ta c to r
1 2 3 4 5 6
T1 T2
L 2L 1
1 2
C o n tr o l B o x
1 2 3 4 5 6
S a u n a H e a te r
E le m e n t 1E le m e n t 2
E le m e n t 3
65
4
32
1
To H ig h L i m i t
T o H ig h L im it
H ig h L im it S w i tc h
G r o u n d T e rm in a l
Fu seA s se m b l i e s
S c a nd i a e l e c t r ic h ea t e r s
a r e U L lis t ed
T o c o n ta c to r co il s
T o c o n ta cto r co il s
Series W atts Volts Am ps Phase Mas Room Size Circuit Breaker Supply W ires (incl ground) W ires from control to heater
120 12000 240 / 208 50 /57.7 1 120 sq ft 60/70 (240V, 3qty #6) 208V, 3qty #4) 7 qty #10 ga - 2 qty #14
150 15000 240 / 208 62.5 / 72.2 1 180 sq ft 70/90 (240V, 3qty #4) 208V, 3qty #2) 7 qty #10 ga - 2 qty #14
150-3 15000 240 / 208 36.2 / 41.7 3 180 sq ft 50 (240V, 4qty #8) 208V, 4qty #6) 7 qty #10 ga - 2 qty #14
180 18000 240 / 208 75 / 86.6 1 240 sq ft 90/100 3qty #2 7 qty #10 ga - 2 qty #14
180-3 18000 240 / 208 43.4 / 50 3 240 sq ft 60 4qty #6 7 qty #10 ga - 2 qty #14
E2
cont
rol
E2 Controls (60 minute timer) 15000‐18000 Watt 240/208 Volt 3‐ phase
7
L 1 T 1 T 2 L 2
C o n ta c to r
C o n ta c t o r
C o n tro l B o x
1 2 3T o H ig h
L im i t
1 2
T o co n ta ctor
co il s
T o co n ta ctor
co il s
T im e r
T -s ta t
T
L
WIRING DIAGRAMS
Converting 60 minute timer to 24 hr programmable timer.
E2
cont
rol
G ro u n dS i n g le P h a s e
T o E le m e n t s
C o n t a c t o r
C o n t a c t o r
C o n t a c t o r
C o n t a c t o r
1 2 3 4 5 6
T 1 T 2
L 2L 1
1 2
C o n tr o l B o x
1 2 3 4 5 6
S a u n a H e a te r
E le m e n t 1E le m e n t 2
E le m e n t 3
65
4
32
1
T o H i g h L i m i t
T o H i g h L im i t
H i g h L i m it S w it c h
G ro u n d T e r m in a l
F u s eA s s e m b l ie s
S c a n d ia e le c t r ic h e a t e r s
a re U L l i s t e d
T o c o n t a c t o r c o i ls
T o c o n t a c t o r c o il s
E 2 C o n t r o l f o r S c a n d i a / V i c o 1 2 K W , 1 5 K W a n d 1 8 K W H e a te r 2 0 8 V a n d 2 4 0 V (S i n g l e P h a s e C o n f i g u r a t i o n )
S eries W a tts V o lts A m ps P hase M as R oom S ize C ircu it B reake r S upp ly W ires (inc l g round) W ires from con tro l to hea te r
120 12000 240 / 208 50 /57 .7 1 120 sq ft 60 /70 (240V , 3q ty #6 ) 208V , 3q ty #4 ) 7 q ty #10 ga - 2 q ty #14
150 15000 240 / 208 62 .5 / 72 .2 1 180 sq ft 70 /90 (240V , 3q ty #4 ) 208V , 3q ty #2 ) 7 q ty #10 ga - 2 q ty #14
Watts Voltage Amps Phase Max Room Size Circuit Breaker Supply Wires (Inc.Ground) Wires (Control to Heater)
12000 240/208 50 / 57.7 1 120 sq ft 60 / 70 240 3 #6 / 208 3 #4 7 qty #10 ‐ 2 qty #14
15000 240/208 62.5 / 72.2 1 180 sq ft 70 / 90 240 3 #4 / 208 3 #2 7 qty #10 ‐ 2 qty #14
18000 240/208 75 / 86.6 1 240 sq ft 90 / 100 3 qty #2 7 qty #10 ‐ 2 qty #14
E2 Controls (60 minute timer) 12000‐18000 Watt 240/208 Volt single phase ‐ T‐Models
1 2
T -s ta t
E2
cont
rol
E le m e n t 1E le m e n t 2
E le m e n t 3
65
4
32
1
T o H ig h L im it
H ig h L im it S w i tc h
G r o u n d T e rm in a l
S c a nd i a e l e c t r ic h ea t e r s
a r e U L lis t ed
1 2
T -s ta t
G ro u n d
n ts
C o n ta c to r
C o n ta ct o r
C o n ta c to r
C o n ta c to r
1 2 3 4 5 6
1 2 3 4 5 6
F u seA s se m b l i e s
T o c o n ta c to r co il s
r
T h r e e P h a se P o w e r F e e d
To E le m e n
T1 T2
L 2L 1
1 2
To H ig h L i m i t
T o c o n ta ctoco il s
Watts Voltage Amps Phase Max Room Size Circuit Breaker Supply Wires (Inc.Ground) Wires (Control to Heater)
12000 240/208 29 / 33.4 3 120 sq ft 40 / 50 240 3 #6 / 208 3 #4 7 qty #10 ‐ 2 qty #14
15000 240/208 36.2 / 41.7 3 180 sq ft 50 240 4 #8 / 208 4 #6 7 qty #10 ‐ 2 qty #14
18000 240/208 43.4 / 50 3 240 sq ft 60 3 qty #6 7 qty #10 ‐ 2 qty #14
E2 Controls (60 minute timer) 12000‐18000 Watt 240/208 Volt 3‐ phase ‐ T‐Models
Controls Sauna Heater
8
L 1 T 1 T 2 L 2
L1 L2 T1
T2
C o n ta c to r
C o n ta c t o r
C o n tro l B o x
1 2 3T o H ig h
L im i t
1 2
T o co n ta ctor
co il s
T o co n ta ctor
co il s
T im e r
T -s ta t
T
L
WIRING DIAGRAMS
Converting 60 minute timer to 24 hr programmable timer.
9
SAUNA HEATER OPERATING INSTRUCTIONS
Installation steps: A. Remove the protective cover off the heater shell. B. Hang the heater in place or as specified by manufacturer. C. Fill the heater rock tray with the sauna rocks. Note: This sauna heater should not be operated without the recommended quantity of rocks. D. ENSURE GOOD AIR CIRCULATION AROUND SENSOR BULB. Install the heater guard around rail around heater. After installation is completed, the heater should be turned on to maximum temperature for one hour to break any rocks having fault lines and to burn off the protective coating on the heater elements. Do not enter the sauna room during the initial start-up. The smell of smoke and cracking of rocks will not re-occur. Sauna Timer: Scandia’ Sauna controls come with standard 60 minute timer (wall mounted outside the sauna) and thermostat . For T models, the thermostat is located on the heater. To turn on the heater, turn the timer knob up the desired time (up to the 60 min. mark). Leave knob at the setting and sauna will operate for one hour before shutting off auto-matically. Allow 30 minutes for room to heat up to an average sauna temperature. The thermostat is marked with numbers 1 through 10. With 1 being the coolest temperature and 10 the highest. Set the desired temperature. Note: Make sure the thermostat is on before setting up the time, otherwise the heater will not heat up.’’ For 24-hour timer operation, see attached Operating Guidelines for 24-hour digital timer. Product Liability: The buyer acknowledges that the goods sold to them by Scandia Manufacturing can cause property damage and personal injury if not properly sized, handled or installed. The buyer further agrees to indemnify and hold harmless Scandia Manufacturing from any or all claims for damage, loss and/or liability arising out of improper handling, siz-ing and/or installation of goods.
SAUNA HEATER OPERATING INSTRUCTIONS
10
Display
Reset port to cancel all prior settings
ON/AUTO/OFF Selection Key
Indicator LED “ON” when connected to power source and contacts are closed.
When programming is done, press the CLOCK key then the MANUAL key repeatedly until the indicator bar is above the word “AUTO” To Review Program: Press TIMER key repeatedly. When done, press CLOCK key to return to the time of day. To Cancel/Change Part of the Program: Press TIMER key repeatedly until the particular ON or OFF time appears, the repeatedly press the DAY key until the display show “ - - - - “ Set new ON and OFF time. ( See: To Set Programs ) To Override Automatic Operation: Press MAMUAL key to move indicator bar to the desired ON or OFF position. Note: Timer will not resume automatic operation until indicator bar is repositioned above the word AUTO.
Programming Instructions 24 digital hour timer
To Set or Change the Day and Time: To clear entire memory, press key. Hold down the CLOCK key while pressing either the DAY, HOUR or MINUTES keys. Continue pressing until the desired day or number is shown. Then simply lift finger off of the CLOCK key to set. To Set Program (ON/OFF times): Press TIMER key once to enter into program mode. Display will show “1 ON - - - - “ Press DAY key to choose any of 15 dif-ferent day combinations for the first ON time. Note: days of the week having the same program should be copied by selecting the desired combination of days. Press the HOUR key and then the MINUTE key to select the de-sired first ON time. Press TIMER key once. Display will show “1 OFF - - - - “. Repeat previous step to select the desired OFF time. Repeat the entire sequence to complete up to eight ON/OFF times as de-sired.
11
ULTRA SAUNA - WARRANTY
Your Ultra Sauna heater has been engineered and built to the highest quality standards, and is backed by this warranty to as-sure your complete satisfaction:
(1) SCANDIA Mfg warrants on the terms and conditions set forth below for ten years to the Original Owner only, at the Original Installation site only, this equipment to be free from defect in material and/or workmanship under normal use as specified in the equipment’s instructions, FROM DATE OF PURCHASE and thereafter.
(2) A TEN YEAR LIMITED WARRANTY applies only on the heater unit as manufactured by and at SCANDIA Mfg., - Manufacturing Plant – and specifically excludes all components and/or parts which are accessories therein, namely: the gas valve; pilot generator: heating element; contactor; timer switch; thermostat; and, high limit, for which their respective manufacturers warranties apply. The TEN YEAR LIMITED WARRANTY does not apply for units that have been installed in commercial locations such as clubs, condominiums, apartments, spas or military facilities. In commercial locations, Scandia will provide a one-year warranty on the unit.
(3) During the first year SCANDIA will, at its option, repair or exchange at the Factory all parts which it finds have become inoperative during said warranty period due to a defect in material or workmanship, without cost to cus-tomer except for freight and/or crating charges.
(4) For the period commencing with the second year and for the ten year warranty of the original purchaser only, at the original installation only, SCANDIA will, at its option, repair or exchange at the Factory, all parts which it finds have become inoperative during said warranty period due to a defect in material or workmanship except the following parts which are excluded from this warranty: the gas valve; pilot generator: heating element; con-tactor; timer switch; thermostat; and, high limit.
(5) This warranty in its entirety becomes null and void if unit is rented or to be used for rental purposes or installed in any mobile or fixed prefab rental room. If original purchaser is a corporation then, the president of said cor-poration, shall be construed as registered Original Owner for all purposes herein, otherwise this warranty in its entirety becomes null and void.
(6) This warranty in its entirety becomes null and void if unit has been installed by an unlicensed party by and/or in the city and/or county where installation is made. Furthermore if unit is disassembled and/or tampered with in any way possible by any one (individual and/or company) then this warranty in its entirety becomes null and void.
SCANDIA reserves the right to substitute new equipment or parts on any orders for replacement hereunder, but shall not be obligated to do so. This warranty is solely for the benefit of the original purchaser and no one else, and only if the installation and operating instructions applicable to the model purchased are followed. These instructions are furnished with the unit and also are available by writing SCANDIA’s warehouse. These instructions are incorporated herein by reference as if set forth in full. This warranty does not cover damages which appear to SCANDIA to have resulted from neglect, alteration, abuse, mis-use, accident, flood, fore or other act of force majeure, or other than normal use. This warranty is expressly in lieu of other warranties, or liabilities, express or implied, by the Company or its representatives, and in lieu of all other obligations and liabilities for damage to persons or property caused in any manner by the heater or its component parts. More specifically, by not by way of limitation, SCANDIA assumes no liability for damages which may occur as a result of neglect or intentional misuse of the unit, and the purchaser or user of the unit agrees to assume all liability for the consequences of its use or misuse by such purchaser or user, and his, its or their respective employees and agents or other third person. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. NO REPRESENTATION OR WARRANTIES ARE MADE, EXPRESSED OR IMPLIED, OTHER THAN THOSE EXPRESSLY HEREIN SET FORTH TO THE ORIGINAL PURCHASER ONLY. To obtain the benefits of this Warranty, the inoperative parts and/or complete heater must be sent to Scandia, all shipping and crating charges prepaid. And all repaired or replaced parts or heaters will be returned freight collect. This warranty is effec-tive only when the attached Factory Registration Stub is completed and returned to the manufacturer. Please contact Scandia for return authorization at 877-467-2862 or via e-mail [email protected] Warranty stub must be mailed or completed online within thirty DAYS TO REGISTER AND VALIDATE THIS WAR-RANTY, WHICH BECOMES VALID ONLY IF THE HEATER HAS BEEN PURCHASED DIRECTLY FROM SCANDIA MFG., AND/OR AUTHORIZED DEALERS IN U.S.A., its territories or possessions.
TO VALIDATE WARRANTY VISIT WWW.SCANDIAMFG.COM/PRODUCT_REGISTRATION.HTML AND REGIS-TER YOUR PRODUCT. ALL PRODUCTS MUST BE REGISTERED PRIOR TO ANY WARRANTY CLAIMS.