cee-lock panel installation details

38
CEE-LOCK PANEL INSTALLATION DETAILS BERRIDGE MANUFACTURING COMPANY 800-669-0009 • www.Berridge.com

Upload: others

Post on 19-Mar-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

CEE-LOCK PANEL

INSTALLATION DETAILS

BERRIDGE

MANUFACTURING

COMPANY

800-669-0009 • www.Berridge.com

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
INDEX CLA-1 CLA-1 INSTALLATION INSTRUCTIONS CAI-1 CAI-1 INSTALLATION INSTRUCTIONS CAI-2 CAI-2 INSTALLATION INSTRUCTIONS CAI-3 CAI-3 INSTALLATION INSTRUCTIONS CAI-4 CAI-4 INSTALLATION INSTRUCTIONS CAI-5 CAI-5 INSTALLATION INSTRUCTIONS; ALUMINUM EXPANSION CHART CAI-6(AL) CAI-6(AL) INTRODUCTION TO TYPICAL DETAILS CLA-3 CLA-3 OVERVIEW; STAINLESS STEEL CEE-LOCK CLIPS CLA-4 CLA-4 EAVE DETAIL; SOLID SHEATHING CLA-10 CLA-10 EAVE DETAIL; SOLID SHEATHING W/GUTTER CLA-10G W/GUTTER CLA-10G W/GUTTER CLA-10G CLA-10G RIDGE AND HIP DETAIL; SOLID SHEATHING CLA-20 CLA-20 SHED RIDGE DETAIL; SOLID SHEATHING CLA-22 CLA-22 CEE-LOCK RIDGE CLOSURE CLA-23 CLA-23 RIDGE TERMINATION AT DORMER VALLEY; SLOPES LESS THAN 3:12 CLA-24 CLA-24 RIDGE TERMINATION AT DORMER VALLEY; SLOPES GREATER THAN 3:12 CLA-24A CLA-24A GABLE DETAIL; SOLID SHEATHING CLA-30 CLA-30 GABLE DETAIL; SOLID SHEATHING W/ CLOSURE FLASHING CLA-33C CLA-33C PARAPET DETAIL CLA-40 CLA-40 RAKE WALL AT PARAPET DETAIL CLA-41 CLA-41 HEAD WALL DETAIL; SOLID SHEATHING CLA-51PS CLA-51PS HEAD WALL DETAIL; SOLID SHEATHING W/ REGLET CLA-51R CLA-51R HEAD WALL DETAIL; SOLID SHEATHING W/ SURFACE MOUNT CLA-51SM CLA-51SM RAKE WALL DETAIL; SOLID SHEATHING CLA-53PS CLA-53PS RAKE WALL DETAIL; SOLID SHEATHING W/ REGLET CLA-53R CLA-53R RAKE WALL DETAIL; SOLID SHEATHING W/ SURFACE MOUNT CLA-53SM CLA-53SM SLOPE TRANSITION DETAIL; SOLID SHEATHING CLA-61 CLA-61 VALLEY DETAIL; SOLID SEATHING CLA-70 CLA-70 VALLEY DETAIL; ISOMETRIC CLA-71 CLA-71 TAPERED VALLEY CLA-73A CLA-73A PIPE PENETRATION (PREFERRED METHOD) IN PAN ONLY 4" DIAMETER OR LESS CLA-80 CLA-80 ROOF PENETRATION RECTANGULAR/SQUARE CLA-81 CLA-81 ROOF PENETRATION SECTION A CLA-82 CLA-82 ROOF PENETRATION SECTION B CLA-83 CLA-83 ROOF PENETRATION ISOMETRIC CLA-84 CLA-84 LIGHTNING ROD DETAIL CLA-89 CLA-89 UL 90 ASSEMBLY; CONSTRUCTION NO. 689 - 22 GA. METAL DECK CLA-90 CLA-90 UL 90 ASSEMBLY; CONSTRUCTION NO. 690 - PLYWOOD CLA-91CLA-91
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
INDEX
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-1
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
A. BERRIDGE ALUMINUM CEE-LOCK PANEL: THE BERRIDGE CEE-LOCK PANEL IS AVAILABLE WITH A FIXED BERRIDGE ALUMINUM CEE-LOCK PANEL: THE BERRIDGE CEE-LOCK PANEL IS AVAILABLE WITH A FIXED THE BERRIDGE CEE-LOCK PANEL IS AVAILABLE WITH A FIXED BERRIDGE CEE-LOCK PANEL IS AVAILABLE WITH A FIXED BERRIDGE CEE-LOCK PANEL IS AVAILABLE WITH A FIXED PAN WIDTH OF 16 " WITH A SEAM HEIGHT OF 1 ". THE CEE-LOCK PANELS IS FACTORY FABRICATED 12" WITH A SEAM HEIGHT OF 1 ". THE CEE-LOCK PANELS IS FACTORY FABRICATED 12". THE CEE-LOCK PANELS IS FACTORY FABRICATED AND/OR FIELD FABRICATED USING THE BERRIDGE CL-21 PORTABLE ROLL FORMER. ALTERNATE 11 " 12" PROFILE IS FACTORY FABRICATED AND/OR FIELD FABRICATED USING THE BERRIDGE CL-16 PORTABLE ROLL FORMER. CONTACT BERRIDGE MANUFACTURING FOR AVAILABILITY OF 11 " PROFILE. 12" PROFILE. WHEN SPECIFYING COIL FOR FIELD FORMED PANELS, ORDER 20 " WIDE COIL TO FORM THE 16 " 78" WIDE COIL TO FORM THE 16 " 12" COVERAGE PANEL WITH 1 " HIGH LEG. WHEN SPECIFYING COIL FOR FIELD FORMED PANELS, ORDER 12" HIGH LEG. WHEN SPECIFYING COIL FOR FIELD FORMED PANELS, ORDER WHEN SPECIFYING COIL FOR FIELD FORMED PANELS, ORDER 15 " WIDE COIL TO FORM THE 11 " COVERAGE PANEL WITH 1 " HIGH LEG. PLEASE CONTACT 78" WIDE COIL TO FORM THE 11 " COVERAGE PANEL WITH 1 " HIGH LEG. PLEASE CONTACT 12" COVERAGE PANEL WITH 1 " HIGH LEG. PLEASE CONTACT 12" HIGH LEG. PLEASE CONTACT BERRIDGE MANUFACTURING FOR FURTHER INFORMATION REGARDING THE BERRIDGE CL-21 OR CL-16 PORTABLE ROLL FORMERS. B. MINIMUM SLOPE: THE CEE-LOCK PANEL IS RECOMMENDED FOR ROOF SLOPES OF 1:12 AND MINIMUM SLOPE: THE CEE-LOCK PANEL IS RECOMMENDED FOR ROOF SLOPES OF 1:12 AND THE CEE-LOCK PANEL IS RECOMMENDED FOR ROOF SLOPES OF 1:12 AND GREATER. IN HEAVY SNOW AREAS OR WHERE NUMEROUS FREESE-THAW CYCLES ARE PREVALENT THROUGHOUT THE WINTER, A MINIMUM ROOF SLOPE OF 2 ON 12 IS RECOMMENDED. C. MATERIAL STORAGE: CAUTION MUST BE EXERCISED IN STORAGE OF MATERIAL PRIOR TO INSTALLATION. MATERIAL STORAGE: CAUTION MUST BE EXERCISED IN STORAGE OF MATERIAL PRIOR TO INSTALLATION. CAUTION MUST BE EXERCISED IN STORAGE OF MATERIAL PRIOR TO INSTALLATION. KEEP ALL BERRIDGE PREFINISHED MATERIAL IN A DRY LOCATION WITH ADEQUATE VENTILATION AND OUT OF DIRECT SUNLIGHT. EXPOSURE TO DIRECT SUNLIGHT AND/OR MOISTURE MAY CAUSE THE FACTORY APPLIED STRIPPABLE PLASTIC FILM TO ADHERE TO THE METAL PERMANENTLY AND DISCOLOR THE FINISH. IF THIS SHOULD OCCUR THE PAINT WARRANTY WILL BE VOID. D. STRIPPABLE FILM: THE STRIPPABLE PLASTIC FILM WHICH IS APPLIED OVER MOST BERRIDGE STRIPPABLE FILM: THE STRIPPABLE PLASTIC FILM WHICH IS APPLIED OVER MOST BERRIDGE THE STRIPPABLE PLASTIC FILM WHICH IS APPLIED OVER MOST BERRIDGE PREFINISHED PRODUCTS, PANELS, FLASHINGS, COILS AND FLAT SHEETS MUST BE REMOVED PRIOR TO INSTALLATION E. SOLID SHEATHING REQUIREMENTS: BERRIDGE MANUFACTURING COMPANY RECOMMENDS THE USE OF SOLID SHEATHING REQUIREMENTS: BERRIDGE MANUFACTURING COMPANY RECOMMENDS THE USE OF BERRIDGE MANUFACTURING COMPANY RECOMMENDS THE USE OF EITHER A MINIMUM 22 GAUGE CORRUGATED METAL DECK OR A MINIMUM OF 1/2" WOOD SHEATHING TO PROVIDE SUFFICIENT HOLDING POWER FOR FASTENERS. CONTACT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT FOR USE OF ANY OTHER TYPE OF SOLID SHEATHING. SUBSTRATE SHOULD BE LEVEL TO 1/4" IN 20'-0". FOR ASSEMBLIES WITH RIGID INSULATION OVER THE STRUCTURAL DECK, PROVIDE WOOD BLOCKING EQUAL TO THE DEPTH OF THE INSULATION AT THE PERIMETERS. NOTE: FOR PROJECTS REQUIRING UL 90 ASSEMBLY, REFER TO UL 90 DETAILS. F. SHEATHING INSPECTION: SHEATHING INSPECTION: 1. SHEATHING END JOINTS SHOULD BE STAGGERED. SHEATHING END JOINTS SHOULD BE STAGGERED. 2. ALL END JOINTS SHOULD MEET AT EITHER A JOIST OR RAFTER. ALL END JOINTS SHOULD MEET AT EITHER A JOIST OR RAFTER. 3. BLOCKING OR "H" CLIPS SHOULD BE USED IF JOINTS DO NOT REMAIN FLAT UNDER THE WEIGHT BLOCKING OR "H" CLIPS SHOULD BE USED IF JOINTS DO NOT REMAIN FLAT UNDER THE WEIGHT OF WORKMEN. 4. USE SHIMS TO KEEP ENTIRE SUBSTRATE EVEN; UNEVEN SUBSTRATE WILL RESULT IN USE SHIMS TO KEEP ENTIRE SUBSTRATE EVEN; UNEVEN SUBSTRATE WILL RESULT IN "OIL-CANNING" IN THE PANELS. SUBSTRATE SHOULD BE LEVEL TO 1/4" IN 20'-0". 5. ALL CUTS AT PENETRATIONS SHOULD BE TIGHT, WITHOUT GAPS. ALL CUTS AT PENETRATIONS SHOULD BE TIGHT, WITHOUT GAPS. 6. USE WOOD FRAMED CRICKETS AT LARGE PENETRATIONS. USE WOOD FRAMED CRICKETS AT LARGE PENETRATIONS. 7. MAKE SURE SUBSTRATE JOINTS ARE TIGHT AT ALL HIPS, VALLEYS AND RIDGES. MAKE SURE SUBSTRATE JOINTS ARE TIGHT AT ALL HIPS, VALLEYS AND RIDGES.
AutoCAD SHX Text
INSTALLATION
AutoCAD SHX Text
INSTRUCTIONS
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CAI-1
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
G. FASCIA/RAKE INSPECTION: FASCIA/RAKE INSPECTION: 1. STRIKE A LINE THE FULL LENGTH OF THE FASCIA OR RAKE. IF NOT STRAIGHT, CORRECT WITH SHIMS. 2. MAKE SURE FASCIA/RAKE IS FLUSH WITH SHEATHING. H. UNDERLAYMENT: A BERRIDGE APPROVED 40 MIL MINIMUM, HIGH TEMPERATURE PEEL & STICK UNDERLAYMENT: A BERRIDGE APPROVED 40 MIL MINIMUM, HIGH TEMPERATURE PEEL & STICK A BERRIDGE APPROVED 40 MIL MINIMUM, HIGH TEMPERATURE PEEL & STICK UNDERLAYMENT MUST BE APPLIED OVER SOLID SHEATHING AS SHOWN IN THE BERRIDGE MANUFACTURING COMPANY TYPICAL CEE-LOCK, AND UNDERLAYMENT INSTALLATION DETAILS. THE USE OF ADDITIONAL LAYERS OF UNDERLAYMENT IS REQUIRED ON LOW-SLOPED ROOFS, AT ALL VALLEY CONDITIONS, AT ROOF PENETRATIONS, AND CERTAIN OTHER FLASHING CONDITIONS AS DEPICTED THROUGHOUT THE CEE-LOCK TYPICAL DETAILS. BERRIDGE REQUIRES STRIP IN LAYERS OF UNDERLAYMENT TO BE MINIMUM 36" OR A FULL ROLL AT VALLEY FLASHING AND SQUARE ROOF PENETRATION LOCATIONS, AND MINIMUM 12" AT ALL OTHER FLASHING LOCATIONS. FOR ALL WATERTIGHTNESS WARRANTIES, THE UNDERLAYMENT MUST BE SELECTED FROM THE BERRIDGE APPROVED PEEL AND STICK UNDERLAYMENT AND SEALANTS LIST. BOTH UNDERLAYMENT INSTALLATION DETAILS AND APPROVED UNDERLAYMENTS AND SEALANTS LIST CAN BE FOUND ON BERRIDGE'S WEBSITE: WWW.BERRIDGE.COM I. UNDERLAYMENT INSTALLATION: UNDERLAYMENT INSTALLATION: 1. DO NOT USE ROSIN PAPER UNDER METAL ROOFING PANELS. DO NOT USE ROSIN PAPER UNDER METAL ROOFING PANELS. 2. SWEEP ROOF AREA CLEAN. SWEEP ROOF AREA CLEAN. 3. INSTALL VALLEY UNDERLAYMENT FIRST. INSTALL VALLEY UNDERLAYMENT FIRST. 4. INSTALL UNDERLAYMENT PARALLEL TO EAVE (2 LAYERS REQUIRED AT EAVE), STARTING AT EAVE INSTALL UNDERLAYMENT PARALLEL TO EAVE (2 LAYERS REQUIRED AT EAVE), STARTING AT EAVE AND USING MINIMUM 6" LAPS. USE BERRIDGE APPROVED PEEL AND STICK ON ENTIRE ROOF SHEATHING, AS SHOWN IN THE CEE-LOCK DETAILS. 2 LAYERS REQUIRED AT EAVE REGARDLESS OF SLOPE. 5. REFER TO UNDERLAYMENT DETAILS WHEN VALLEYS OR ROOF PENETRATIONS ARE INVOLVED. REFER TO UNDERLAYMENT DETAILS WHEN VALLEYS OR ROOF PENETRATIONS ARE INVOLVED. 6. INSULATE BETWEEN WOOD BLOCKING AND METAL WITH BERRIDGE APPROVED PEEL AND STICK INSULATE BETWEEN WOOD BLOCKING AND METAL WITH BERRIDGE APPROVED PEEL AND STICK UNDERLAYMENT. 7. BERRIDGE RECOMMENDS STRIP IN LAYERS OF UNDERLAYMENT TO BE MINIMUM 36" OR A FULL BERRIDGE RECOMMENDS STRIP IN LAYERS OF UNDERLAYMENT TO BE MINIMUM 36" OR A FULL ROLL AT VALLEY FLASHING AND SQUARE ROOF PENETRATION LOCATIONS, AND MINIMUM 12" AT ALL OTHER FLASHING LOCATIONS. J. THERMAL MOVEMENT: EXPANSION AND CONTRACTION OF METAL PANELS WHICH EXCEED THIRTY FEET THERMAL MOVEMENT: EXPANSION AND CONTRACTION OF METAL PANELS WHICH EXCEED THIRTY FEET EXPANSION AND CONTRACTION OF METAL PANELS WHICH EXCEED THIRTY FEET IN LENGTH CAN BE A FACTOR IN THE DESIGN AND INSTALLATION OF FLASHING. PLEASE REFER TO THE LINEAR EXPANSION CHART ON PAGE CAI-6 (AL) TO DETERMINE ANTICIPATED THERMAL MOVEMENT OF THE PANELS. IMPROPERLY DESIGNED FLASHING CAN ALLOW PANELS TO DISENGAGE FROM THE FLASHING, ALLOW OIL-CANNING IN THE PANEL AND/OR CAUSE FLASHING TO WORK LOOSE FORM ITS ANCHORAGE. K. ELECTROLYSIS: AVOID ALLOWING FLASHINGS AND PANELS TO COME INTO CONTACT WITH EITHER LEAD ELECTROLYSIS: AVOID ALLOWING FLASHINGS AND PANELS TO COME INTO CONTACT WITH EITHER LEAD AVOID ALLOWING FLASHINGS AND PANELS TO COME INTO CONTACT WITH EITHER LEAD AVOID ALLOWING FLASHINGS AND PANELS TO COME INTO CONTACT WITH EITHER LEAD OR COPPER AND PREVENT EXPOSURE TO WATER RUNDOWN FROM COPPER AND/OR LEAD. L. SEALANT REQUIREMENTS: FOR A FULL LIST OF APPROVED SEALANTS VISIT: WWW.BERRIDGE.COMSEALANT REQUIREMENTS: FOR A FULL LIST OF APPROVED SEALANTS VISIT: WWW.BERRIDGE.COMFOR A FULL LIST OF APPROVED SEALANTS VISIT: WWW.BERRIDGE.COM
AutoCAD SHX Text
APPROVED UNDERLAYMENTS AND SEALANTS
AutoCAD SHX Text
UNDERLAYMENT INSTALLATION DETAILS
AutoCAD SHX Text
APPROVED UNDERLAYMENTS AND SEALANTS
AutoCAD SHX Text
INSTALLATION
AutoCAD SHX Text
INSTRUCTIONS
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CAI-2
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
N. FLASHING: IF BERRIDGE MANUFACTURING COMPANY IS TO SUPPLY FLASHINGS, ALL FLASHINGS WILL BE FLASHING: IF BERRIDGE MANUFACTURING COMPANY IS TO SUPPLY FLASHINGS, ALL FLASHINGS WILL BE IF BERRIDGE MANUFACTURING COMPANY IS TO SUPPLY FLASHINGS, ALL FLASHINGS WILL BE FABRICATED IN 10'-0" LENGTHS WITH SQUARE END CUTS ONLY. THE PURCHASER MUST PROVIDE ALL DIMENSIONS AND DEGREE OF ANGLES. FLASHING INSTALLATION: 1. REMOVE STRIPPABLE PLASTIC FILM FROM ALL FLASHINGS PRIOR TO INSTALLATION. REMOVE STRIPPABLE PLASTIC FILM FROM ALL FLASHINGS PRIOR TO INSTALLATION. 2. ALWAYS STAGGER JOINTS WHEN ONE FLASHING IS INSTALLED OVER OTHER FLASHINGS. ALWAYS STAGGER JOINTS WHEN ONE FLASHING IS INSTALLED OVER OTHER FLASHINGS. 3. INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR THERMAL MOVEMENT. ALL ALUMINUM FLASHINGS MUST BE FASTENED 5" AWAY FROM THE 4" OVERLAP. 4. INSTALL ALL FLASHINGS AS PER BERRIDGE TYPICAL DETAILS. INSTALL ALL FLASHINGS AS PER BERRIDGE TYPICAL DETAILS. 5. ALL FLASHINGS ARE TO BE DESIGNED AND INSTALLED TO NOT TRAP WATER. ALL FLASHINGS ARE TO BE DESIGNED AND INSTALLED TO NOT TRAP WATER. NOTE: WHEN USING POP RIVETS ON ALUMINUM FLASHING, STAINLESS STEEL RIVETS ARE REQUIRED. DO NOT RIVET THROUGH END LAPS. USE #12 PANCAKE HEAD STAINLESS STEEL FASTENERS FOR FLASHING INSTALLATION. MAKE SURE ALL FASTENERS ARE DRIVEN STRAIGHT AND SET FLAT. DO NOT OVERDRIVE FASTENERS AS THIS WILL CAUSE THE FLASHINGS TO BUCKLE OR BECOME RECESSED BELOW THE ELEVATION OF THE SUBSTRATE.. O. PANELS: BERRIDGE MANUFACTURING COMPANY WILL PROVIDE SQUARE END CUTS ONLY ON ALL PANELS: BERRIDGE MANUFACTURING COMPANY WILL PROVIDE SQUARE END CUTS ONLY ON ALL BERRIDGE MANUFACTURING COMPANY WILL PROVIDE SQUARE END CUTS ONLY ON ALL BERRIDGE MANUFACTURING COMPANY WILL PROVIDE SQUARE END CUTS ONLY ON ALL CEE-LOCK PANELS. COMPUTATION OF ALL QUANTITIES AND DIMENSIONS ARE THE RESPONSIBILITY OF THE PURCHASER. PANELS ARE TO BE FIELD CUT WITH SNIPS, NIBBLER, AND/OR SHEARS ONLY. P. PANEL INSTALLATION: PANEL INSTALLATION: 1. REMOVE STRIPPABLE PLASTIC FILM FROM EACH PANEL PRIOR TO INSTALLATION. 2. START PANEL INSTALLATION AT GABLE END OF THE ROOF, WORKING TOWARD THE OTHER GABLE END. MAKE SURE PANELS ARE PERPENDICULAR TO THE EAVE. AT VALLEY AREAS, MAKE SURE PANELS ARE INSTALLED SO THAT DRAINAGE HAS FREE FLOW AND IS NOT OBSTRUCTED BY PANEL SEAMS. 3. BEGIN BY INSTALLING DRIP FLASHING OR CLOSURE FLASHING AT GABLE THEN PLACING THE FIRST CEE-LOCK PANEL. 4. INSTALL STAINLESS STEEL CEE-LOCK CLIPS AS PER BERRIDGE TYPICAL DETAILS AND CEE-LOCK INSTALLATION NOTES. 5. IF OPTIONAL VINYL WEATHERSEAL (US PATENT 4,641,475) IS TO BE USED, THIS WILL BE EITHER FACTORY INSTALLED OR INSTALLED IN THE FIELD AS THE CEE-LOCK PANEL EXITS FROM THE CL-21 OR CL-16 PORTABLE ROLL FORMER. VINYL WEATHERSEAL IS REQUIRED FOR WATERTIGHTNESS WARRANTIES. 6. INSTALL PANELS BY PLACING THE FEMALE LEG OVER THE MALE LEG AND STAINLESS STEEL CEE-LOCK CLIP AND SNAPPING THE INTEGRAL SEAM INTO PLACE WITH HAND PRESSURE. (ALTERNATE METHOD TO SNAP SEAMS TOGETHER IS TO PLACE A 2X4 PIECE OF LUMBER OVER THE CEE-LOCK PANEL SEAM AND STRIKE IT WITH A MALLET TO LOCK THE PANEL TOGETHER) DO NOT USE EXCESSIVE FORCE OR FOOT PRESSURE, DO NOT KICK, STOMP OR DIRECTLY HAMMER TO ENGAGE THE PANEL SIDE LAP. AS THIS WILL SCRATCH OR DENT THE PANEL, DAMAGE THE PANEL RIB/CLIP AND CAUSE DEFORMATION TO THE VINYL WEATHERSEAL. 7. EACH PANEL IS TO BE KEPT TIGHT AGAINST THE LEG OF THE ADJOINING PANEL. NEVER PERMIT A GAP BETWEEN VERTICAL LEGS. 8. KEEP PANELS ALIGNED SO THAT SEAMS MATCH AT HIPS, VALLEYS AND WHERE VERTICAL PANELS ADJOIN ROOF PANELS. DO NOT INSTALL LONG CONTINUOUS RUNS OF PANELS ALL AT ONE TIME WHERE SEAM LINES MUST MATCH. INSTALL 10 OR 12 PANELS IN ONE ELEVATION ANDN THEN FOLLOW WITH A LIKE NUMBER OF PANELS ON THE OTHER ELEVATION. WHEN YOU INSTALL PANELS IN THIS MANNER, YOU WILL BE ABLE TO MAKE ANY ADJUSTMENTS REQUIRED TO INSURE SEAM MATCHING.
AutoCAD SHX Text
INSTALLATION
AutoCAD SHX Text
INSTRUCTIONS
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CAI-3
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
9. METALLIC FINISHES: PANEL INSTALLATION: NOTE THE SERIES OF ARROWS PAINTED ON THE UNDERSIDE OF THE PANEL. ALL PANELS MUST BE INSTALLED IN CONSISTENT MANNER, MEANING THAT THE ARROWS ON EVERY PANEL ARE ALL POINTING IN THE SAME DIRECTION. IF A PANEL IS REVERSED (ARROWS POINTING OPPOSITE OF THOSE ON OTHER PANELS) IT WILL APPEAR FROM A DISTANCE, A DIFFERENT SHADE DUE TO THE GRANULAR EFFECT OF THE PIGMENTS IN THE FINISH. METALLIC FINISHES ARE MATCH - METALLIC FINISHES ARE MATCH - LOT FINISHES. DO NOT MIX LOTS. Q. STAINLESS STEEL CEE-LOCK CLIPS: STAINLESS STEEL CEE-LOCK CLIPS: 1. INSTALL STAINLESS STEEL CEE-LOCK CLIPS AS PER BERRIDGE TYPICAL CEE-LOCK PANEL DETAILS. *NOTE: IF LOCAL CODES OR OTHER REGULATIONS DICTATE SPECIFIC WIND UPLIFT REQUIREMENTS, CONSULT BERRIDGE ENGINEERING DEPARTMENT, AS IT MAY BE NECESSARY TO USE A DIFFERENT FASTENER PATTERN. R. FASTENERS: INSTALL FASTENERS AS PER TYPICAL DETAILS. USE LOAD CHARTS UNDER THE FASTENERS: INSTALL FASTENERS AS PER TYPICAL DETAILS. USE LOAD CHARTS UNDER THE INSTALL FASTENERS AS PER TYPICAL DETAILS. USE LOAD CHARTS UNDER THE INSTALL FASTENERS AS PER TYPICAL DETAILS. USE LOAD CHARTS UNDER THE "DOWNLOADS" TAB ON WWW.BERRIDGE.COM FOR FASTENER RECOMMENDATIONS ACCORDING TO SUBSTRATE.** MAKE SURE ALL FASTENERS ARE DRIVEN STRAIGHT AND SET FLAT. DO NOT OVERDRIVE FASTENERS AS THIS WILL CAUSE THE CLIP AND/OR FLASHINGS TO BUCKLE OR BECOME RECESSED BELOW THE ELEVATION OF THE SUBSTRATE. **CONSULT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT REGARDING THE USE OF ANY OTHER TYPE OF FASTENER. S. UNDERWRITERS LABORATORIES RATINGS: THE BERRIDGE CEE-LOCK PANEL COMPLIES WITH UL TEST UNDERWRITERS LABORATORIES RATINGS: THE BERRIDGE CEE-LOCK PANEL COMPLIES WITH UL TEST THE BERRIDGE CEE-LOCK PANEL COMPLIES WITH UL TEST PROCEDURE NO. 580 "TEST FOR WIND UPLIFT RESISTANCE OF ROOF ASSEMBLIES" CLASS UL 90 CONSTRUCTIONS REFER TO DETAILS CLA-90 & CLA-91. BERRIDGE MANUFACTURING COMPANY STRIVES TO PROVIDE ITS CUSTOMERS WITH THE HIGHEST QUALITY STRETCHER LEVELED STEEL AVAILABLE. THE LATEST TECHNOLOGY IS ALSO INCORPORATED IN BERRIDGE'S HIGH-PRECISION COIL HANDLING AND ROLL FORMING EQUIPMENT TO MINIMIZE THE STRESS ON METAL DURING PRODUCTION. ALL THESE MEASURES HAVE BEEN TAKEN TO MINIMIZE THE AMOUNT OF "OIL-CANNING" (WAVINESS) WHICH IS NATURALLY INHERENT IN FLAT SHEET METAL. MANY TIMES; HOWEVER, THE CAUSE OF WAVINESS OR "OIL-CANNING" CAN BE TRACED TO UNEVEN SHEATHING, IMPROPER UNDERLAYMENT INSTALLATION, OR IN THE CASE OF OPEN FRAMING, UNEVENNESS OF THE TOP PLANE OF THE PURLINS OR FOOT TRAFFIC ON THE PANELS. ALL ARCHITECTURAL PANELS REQUIRE CARE IN HANDLING AND INSTALLATION TO AVOID DAMAGING OR DEFORMING THE PANELS. THESE INSTALLATION INSTRUCTIONS AND THE FOLLOWING TYPICAL DETAILS ARE INTENDED TO PROVIDE OUR CUSTOMERS WITH THE INFORMATION REQUIRED FOR AN AESTHETICALLY PLEASING AND FUNCTIONAL INSTALLATION OF THE BERRIDGE CEE-LOCK PANEL SYSTEM. NOTE: ALL PRODUCT SPECIFICATIONS, DETAILS AND INSTALLATION INSTRUCTIONS SUBJECT TO CHANGE ALL PRODUCT SPECIFICATIONS, DETAILS AND INSTALLATION INSTRUCTIONS SUBJECT TO CHANGE WITHOUT NOTICE. FOR SPECIFIC PROJECT DETAILS, CONTACT BERRIDGE.
AutoCAD SHX Text
CEE-LOCK LOAD CHARTS
AutoCAD SHX Text
INSTALLATION
AutoCAD SHX Text
INSTRUCTIONS
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CAI-4
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
100%%D F
AutoCAD SHX Text
140%%d F
AutoCAD SHX Text
180%%d F
AutoCAD SHX Text
220%%d F
AutoCAD SHX Text
260%%d F TEMPERATURE CHANGE
AutoCAD SHX Text
DISTANCE FROM FIXED POINT IN FEET
AutoCAD SHX Text
TOTAL MOVEMENT ("A") IN INCHES - FOR ALUMINUM PANELS
AutoCAD SHX Text
12"
AutoCAD SHX Text
1"
AutoCAD SHX Text
1 "12"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2 "12"
AutoCAD SHX Text
3"
AutoCAD SHX Text
3 "12"
AutoCAD SHX Text
4"
AutoCAD SHX Text
4 "12"
AutoCAD SHX Text
5"
AutoCAD SHX Text
5 "12"
AutoCAD SHX Text
6"
AutoCAD SHX Text
6 "12"
AutoCAD SHX Text
7"
AutoCAD SHX Text
7 "12"
AutoCAD SHX Text
8"
AutoCAD SHX Text
0
AutoCAD SHX Text
10
AutoCAD SHX Text
20
AutoCAD SHX Text
30
AutoCAD SHX Text
40
AutoCAD SHX Text
50
AutoCAD SHX Text
60
AutoCAD SHX Text
70
AutoCAD SHX Text
80
AutoCAD SHX Text
90
AutoCAD SHX Text
100
AutoCAD SHX Text
110
AutoCAD SHX Text
120
AutoCAD SHX Text
130
AutoCAD SHX Text
140
AutoCAD SHX Text
150
AutoCAD SHX Text
160
AutoCAD SHX Text
170
AutoCAD SHX Text
180
AutoCAD SHX Text
190
AutoCAD SHX Text
200
AutoCAD SHX Text
(1/4" INCREMENTS)
AutoCAD SHX Text
EXPANSION AND CONTRACTION OF ALUMINUM PANELS DUE TO LONGITUDINAL THERMAL MOVEMENT MUST BE CONSIDERED IN BOTH DESIGN AND INSTALLATION. THE ABOVE CHART EMPHASIZES THE NEED TO PROVIDE AMPLE CLEARANCES FROM GUTTERS, RIDGES, ENDWALL, ETC.
AutoCAD SHX Text
MAXIMUM TEMPERATURE SHOULD BE NO LOWER THAN 140°F FOR WHITE PANELS, UPTO 180° FOR DARK PAINTED PANELS, REGARDLESS OF AMBIENT MAXIMUM, MINIMUMSHOULD BE FIGURED WELL BELOW AMBIENT MINIMUM TO ALLOW FOR RADIATION TO NIGHT SKY. IN ANY CASE, A MINIMUM OF 100°F DIFFERENTIAL IS RECOMMENDED.
AutoCAD SHX Text
ALUMINUM PANEL EXPANSION CHART
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
INSTALLATION INSTRUCTIONS
AutoCAD SHX Text
NOMINAL LINEAR EXPANSION
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CAI-6(AL)
AutoCAD SHX Text
DATE: 1/21

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
THE DETAILS CONTAINED IN THE FOLLOWING PAGES ARE MERELY RECOMMENDATIONS AS TO HOW BERRIDGE MANUFACTURING MATERIALS SHOULD BE INSTALLED. THEY MAY REQUIRE ADAPTATIONS OR MODIFICATIONS FOR A SPECIFIC PROJECT AS CONDITIONS VARY IN BOTH BUILDING DESIGN AND LOCAL WEATHER PECULIARITIES. BERRIDGE MANUFACTURING COMPANY SHOULD BE HELD HARMLESS FROM ANY AND ALL CLAIMS ARISING FROM LACK OF WATERTIGHTNESS AS A RESULT OF FOLLOWING THESE RECOMMENDED DETAILS. ENSURING WATERTIGHTNESS ON ANY GIVEN PROJECT IS THE FUNCTION OF THE INSTALLER. THE ARCHITECT/GENERAL CONTRACTOR/INSTALLER MUST ACCEPT THE RESPONSIBILITY TO ADAPT THESE DETAILS TO MEET PARTICULAR BUILDING REQUIREMENTS AND TO ASSURE ADEQUATE WATERTIGHTNESS. THE INSTALLER CAN VIRTUALLY ASSURE WATERTIGHTNESS IF THESE FLASHING DETAILS HAVE BEEN PROPERLY ADAPTED, ADEQUATE LAPS HAVE BEEN PROVIDED, CORRECT TYPE OF SEALANT USED, ALL JOINTS ADEQUATELY CAULKED, AND PROFESSIONAL WORKMANSHIP EMPLOYED.
AutoCAD SHX Text
INTRODUCTION TO
AutoCAD SHX Text
TYPICAL DETAILS
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-3
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-4
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
%%U STAINLESS STEEL
AutoCAD SHX Text
%%U SEAM SECTION
AutoCAD SHX Text
PANEL OVERVIEW
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIP
AutoCAD SHX Text
PATENTED VINYL WEATHERSEAL US PATENT NO. 4,641,475.
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
PATENTED VINYL WEATHERSEAL US PATENT NO. 4,641,475.
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIP
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
CONTACT BERRIDGE MANUFACTURING FOR AVAILABILITY OF THE ALTERNATE 11 " PANEL PROFILEBERRIDGE MANUFACTURING FOR AVAILABILITY OF THE ALTERNATE 11 " PANEL PROFILE FOR AVAILABILITY OF THE ALTERNATE 11 " PANEL PROFILE12" PANEL PROFILE
AutoCAD SHX Text
%%U CEE-LOCK CLIP
AutoCAD SHX Text
%%U PANEL SECTION - .032 ALUMINUM
AutoCAD SHX Text
FASTENERS - SEE LOAD CHARTS AVAILABLE UNDER "DOWNLOADS" TAB AT WWW.BERRIDGE.COM
AutoCAD SHX Text
NOTE: CONTINUOUS RIB AND VINYL WEATHERSEAL REQUIRED FOR WATERTIGHTNESS WARRANTY

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
MIN. 1" OR MAXIMUM EXPANSION OF PANEL + 1/2"
AutoCAD SHX Text
EAVE FLASHING
AutoCAD SHX Text
F
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIPS; 2 AT EAVE
AutoCAD SHX Text
FIELD CUT SEAM AND FORM PANEL PAN AROUND EAVE FLASHING
AutoCAD SHX Text
GAP; SEE NOTE 1 BELOW
AutoCAD SHX Text
MAXIMUM EXPANSION OF PANEL + 1/2"
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT. INSTALL MIN. 12" STRIP PLY OVER EAVE FLASHING.
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
EAVE FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS
AutoCAD SHX Text
1. THE "GAP" BETWEEN EAVE FLASHING AND PANEL (SEE DETAIL ABOVE) CAN BE INCREASED TO ALLOW THE "GAP" BETWEEN EAVE FLASHING AND PANEL (SEE DETAIL ABOVE) CAN BE INCREASED TO ALLOW FOR LINEAR EXPANSION AND CONTRACTION OF PANELS. NOTE 1/2" OF PAN MUST BE ENGAGED WITH EAVE FLASHING WHEN PANEL HAS EXPANDED TO ITS MAXIMUM LENGTH REFER TO NOMINAL LINEAR EXPANSION CHART 2. GAP BETWEEN EAVE FLASHING AND PANEL MUST BE ADJUSTED TO SUIT TEMPERATURE DURING GAP BETWEEN EAVE FLASHING AND PANEL MUST BE ADJUSTED TO SUIT TEMPERATURE DURING INSTALLATION. 3. SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS MINIMUM REQUIREMENTS, REFERENCE INSTALLATION INSTRUCTIONS. 4. INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR THERMAL MOVEMENT. ALL ALUMINUM FLASHINGS MUST BE FASTENED 5" AWAY FROM THE 4" OVERLAP. 5. REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT REGARDING FASTENER TYPE & SPACING. (REFERENCE INSTALLATION INSTRUCTIONS & LOAD CHARTS FOR MIN. FASTENER REQUIREMENTS)
AutoCAD SHX Text
F = FINISH SIDE FV = FIELD VERIFY
AutoCAD SHX Text
NOTE:ALL FLASHING GAUGES TO BE ALL FLASHING GAUGES TO BE EQUAL TO THE ASSOCIATED PANEL GAUGE UNLESS NOTED OTHERWISE
AutoCAD SHX Text
NOTE: WHEN USING POP RIVETS ON FLASHING, STAINLESS STEEL RIVETS ARE REQUIRED WITH ALUMINUM PANELS. FLASHINGS MUST NOT BE FASTENED AT LAPS.
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-10
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
EAVE DETAIL PANEL TURNDOWN
AutoCAD SHX Text
SOLID SUBSTRATE

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
MIN. 1" OR MAXIMUM EXPANSION OF PANEL + 1/2"
AutoCAD SHX Text
EAVE FLASHING
AutoCAD SHX Text
F
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL
AutoCAD SHX Text
FIELD CUT SEAM AND FORM PANEL PAN AROUND EAVE FLASHING
AutoCAD SHX Text
GAP; SEE NOTE 1 BELOW
AutoCAD SHX Text
MAXIMUM EXPANSION OF PANEL + 1/2"
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT. INSTALL MIN. 12" STRIP PLY OVER EAVE FLASHING.
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
EAVE FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS
AutoCAD SHX Text
GUTTER (NOT BY BERRIDGE)
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIPS; 2 AT EAVE
AutoCAD SHX Text
1. THE "GAP" BETWEEN EAVE FLASHING AND PANEL (SEE DETAIL ABOVE) CAN BE INCREASED TO ALLOW THE "GAP" BETWEEN EAVE FLASHING AND PANEL (SEE DETAIL ABOVE) CAN BE INCREASED TO ALLOW FOR LINEAR EXPANSION AND CONTRACTION OF PANELS. NOTE 1/2" OF PAN MUST BE ENGAGED WITH EAVE FLASHING WHEN PANEL HAS EXPANDED TO ITS MAXIMUM LENGTH REFER TO NOMINAL LINEAR EXPANSION CHART 2. GAP BETWEEN EAVE FLASHING AND PANEL MUST BE ADJUSTED TO SUIT TEMPERATURE DURING GAP BETWEEN EAVE FLASHING AND PANEL MUST BE ADJUSTED TO SUIT TEMPERATURE DURING INSTALLATION. 3. SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS MINIMUM REQUIREMENTS, REFERENCE INSTALLATION INSTRUCTIONS. 4. INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR THERMAL MOVEMENT. ALL ALUMINUM FLASHINGS MUST BE FASTENED 5" AWAY FROM THE 4" OVERLAP. 5. REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT REGARDING FASTENER TYPE & SPACING. (REFERENCE INSTALLATION INSTRUCTIONS & LOAD CHARTS FOR MIN. FASTENER REQUIREMENTS)
AutoCAD SHX Text
F = FINISH SIDE FV = FIELD VERIFY
AutoCAD SHX Text
NOTE:ALL FLASHING GAUGES TO BE ALL FLASHING GAUGES TO BE EQUAL TO THE ASSOCIATED PANEL GAUGE UNLESS NOTED OTHERWISE
AutoCAD SHX Text
NOTE: WHEN USING POP RIVETS ON FLASHING, STAINLESS STEEL RIVETS ARE REQUIRED WITH ALUMINUM PANELS. FLASHINGS MUST NOT BE FASTENED AT LAPS.
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-10G
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
EAVE WITH GUTTER DETAIL
AutoCAD SHX Text
SOLID SHEATHING

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
RIDGE/HIP DETAIL
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
F
AutoCAD SHX Text
ZEE CLOSURE
AutoCAD SHX Text
RIDGE/HIP CAP
AutoCAD SHX Text
OPEN HEMS
AutoCAD SHX Text
F
AutoCAD SHX Text
RIDGE/HIP CAP; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS. POP RIVET TO ZEE CLOSURE 16" O.C. MAX.
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; MIN. 3 PER ZEE CLOSURE
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK BETWEEN CEE-LOCK PANEL AND ZEE CLOSURE
AutoCAD SHX Text
ZEE CLOSURE CUT TO FIT BETWEEN SEAMS AT HIPS. USE CLA-23 AT RIDGE
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIPS
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT
AutoCAD SHX Text
1. SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS MINIMUM REQUIREMENTS, REFERENCE INSTALLATION INSTRUCTIONS. 2. INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR THERMAL MOVEMENT. ALL ALUMINUM FLASHINGS MUST BE FASTENED 5" AWAY FROM THE 4" OVERLAP. 3. REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT REGARDING FASTENER TYPE & SPACING. (REFERENCE INSTALLATION INSTRUCTIONS & LOAD CHARTS FOR MIN. FASTENER REQUIREMENTS)
AutoCAD SHX Text
F = FINISH SIDE FV = FIELD VERIFY
AutoCAD SHX Text
NOTE:ALL FLASHING GAUGES TO BE ALL FLASHING GAUGES TO BE EQUAL TO THE ASSOCIATED PANEL GAUGE UNLESS NOTED OTHERWISE
AutoCAD SHX Text
NOTE: WHEN USING POP RIVETS ON FLASHING, STAINLESS STEEL RIVETS ARE REQUIRED WITH ALUMINUM PANELS. FLASHINGS MUST NOT BE FASTENED AT LAPS.
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-20
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
RIDGE CAP; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS, POP RIVET TO ZEE CLOSURE/CLEAT 16" O.C. MAX.
AutoCAD SHX Text
OPEN HEMS
AutoCAD SHX Text
SHED RIDGE DETAIL
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; MIN. 3 PER ZEE CLOSURE
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIPS
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT. LAP OVER RIDGE
AutoCAD SHX Text
ZEE CLOSURE; USE CLA-23 AT RIDGE. CUT TO FIT BETWEEN SEAMS AT SKEWED AREAS.
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK BETWEEN ZEE CLOSURE AND CEE-LOCK PANEL.
AutoCAD SHX Text
CONTINUOUS CLEAT WITH STAINLESS STEEL FASTENERS 16" O.C. MAX.
AutoCAD SHX Text
F
AutoCAD SHX Text
RIDGE CAP
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
1. SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS MINIMUM REQUIREMENTS, REFERENCE INSTALLATION INSTRUCTIONS. 2. INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR THERMAL MOVEMENT. ALL ALUMINUM FLASHINGS MUST BE FASTENED 5" AWAY FROM THE 4" OVERLAP. 3. REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT REGARDING FASTENER TYPE & SPACING. (REFERENCE INSTALLATION INSTRUCTIONS & LOAD CHARTS FOR MIN. FASTENER REQUIREMENTS)
AutoCAD SHX Text
F = FINISH SIDE FV = FIELD VERIFY
AutoCAD SHX Text
NOTE:ALL FLASHING GAUGES TO BE ALL FLASHING GAUGES TO BE EQUAL TO THE ASSOCIATED PANEL GAUGE UNLESS NOTED OTHERWISE
AutoCAD SHX Text
NOTE: WHEN USING POP RIVETS ON FLASHING, STAINLESS STEEL RIVETS ARE REQUIRED WITH ALUMINUM PANELS. FLASHINGS MUST NOT BE FASTENED AT LAPS.
AutoCAD SHX Text
F
AutoCAD SHX Text
ZEE CLOSURE
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-22
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
POP RIVETS; 16" O.C. MAX.

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
CEE-LOCK
AutoCAD SHX Text
RIDGE CLOSURE
AutoCAD SHX Text
1. ZEE CLOSURE IS DIE FORMED TO FIT PERPENDICULARLY BETWEEN PANEL SEAMS.
AutoCAD SHX Text
RIDGE
AutoCAD SHX Text
TOP WALL
AutoCAD SHX Text
CEE-LOCK RIDGE CLOSURE
AutoCAD SHX Text
BERRIDGE CEE-LOCK PANEL
AutoCAD SHX Text
SHED RIDGE
AutoCAD SHX Text
CEE-LOCK RIDGE CLOSURE
AutoCAD SHX Text
BERRIDGE CEE-LOCK PANEL
AutoCAD SHX Text
CEE-LOCK RIDGE CLOSURE
AutoCAD SHX Text
1"
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-23
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
FIELD FORM END OF RIDGE FLASHING AND EXTEND UNDER CLEAT
AutoCAD SHX Text
RIDGE FLASHING: 4" END LAPS WITH CONTINUOUS CAULK AT LAPS
AutoCAD SHX Text
FIELD TAPERED ZEE CLOSURE WITH CONTINUOUS CAULK UNDER ZEE CLOSURE
AutoCAD SHX Text
STAINLESS STEEL FASTENERS: 16" ON CENTER MAXIMUM PLACE A DAB OF CAULK AT FASTENER LOCATION DRIVE FASTENER AND CAULK FASTENER HEAD
AutoCAD SHX Text
VALLEY FLASHING: 12" LAPS WITH CONTINUOUS CAULK AT LAPS
AutoCAD SHX Text
%%U SECTION VIEW
AutoCAD SHX Text
%%U PLAN VIEW
AutoCAD SHX Text
CLA-20
AutoCAD SHX Text
RIDGE TERMINATION
AutoCAD SHX Text
SLOPES LESS THAN 3:12
AutoCAD SHX Text
RIDGE FLASHING
AutoCAD SHX Text
VALLEY FLASHING
AutoCAD SHX Text
DORMER PANEL
AutoCAD SHX Text
MAIN ROOF PANELS
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIPS
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT. INSTALL MIN. 36" STRIP PLY OVER RIDGE FLASHING EXTENSION.
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
NOTE: WHEN USING POP RIVETS ON FLASHING, STAINLESS STEEL RIVETS ARE REQUIRED WITH ALUMINUM PANELS. FLASHINGS MUST NOT BE FASTENED AT LAPS.
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-24
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
COVER TRIM: FIELD FORM COVER TRIM AND EXTEND UNDER PANEL. TAB OVER RIDGE FLASHING. SET IN CAULK AND FASTEN WITH S.S. RIVETS.
AutoCAD SHX Text
RIDGE FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS
AutoCAD SHX Text
FIELD TAPERED ZEE CLOSURE WITH CONTINUOUS CAULK UNDER ZEE CLOSURE
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX. PLACE A DAB OF CAULK AT FASTENER LOCATION DRIVE FASTENER AND CAULK FASTENER HEAD
AutoCAD SHX Text
VALLEY FLASHING; 12" LAPS WITH CONTINUOUS CAULK AT LAPS
AutoCAD SHX Text
RIDGE FLASHING
AutoCAD SHX Text
VALLEY FLASHING
AutoCAD SHX Text
DORMER PANEL
AutoCAD SHX Text
TAB RIDGE FLASHING AND SET IN CAULK AT VALLEY INTERSECTION.
AutoCAD SHX Text
CLA-20
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIPS
AutoCAD SHX Text
MAIN ROOF PANELS
AutoCAD SHX Text
%%U SECTION VIEW
AutoCAD SHX Text
%%U PLAN VIEW
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
RIDGE TERMINATION
AutoCAD SHX Text
SLOPES GREATER THAN 3:12
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT. INSTALL MIN. 36" STRIP PLY OVER COVER TRIM FLASHING.
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL
AutoCAD SHX Text
NOTE: WHEN USING POP RIVETS ON FLASHING, STAINLESS STEEL RIVETS ARE REQUIRED WITH ALUMINUM PANELS. FLASHINGS MUST NOT BE FASTENED AT LAPS.
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-24A
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-30
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
FIELD CUT AND FORM LAST PANEL AROUND DRIP FLASHING. (PANEL TO BE CONTINUOUS RIDGE TO EAVE)
AutoCAD SHX Text
DRIP FLASHING: 4" END LAPS WITH CONTINUOUS CAULK AT LAPS
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
DRIP FLASHING
AutoCAD SHX Text
F
AutoCAD SHX Text
GABLE DETAIL
AutoCAD SHX Text
SOLID SUBSTRATE
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIP
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT. INSTALL MIN. 12" STRIP PLY OVER DRIP FLASHING, TOP LAYER TO BE PARALLEL WITH ROOF SLOPE.
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
PANEL TURNDOWN
AutoCAD SHX Text
EXTRUDED VINYL WEATHERSEAL (OPTIONAL) US PATENT NO. 4,641,475.
AutoCAD SHX Text
1. SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS MINIMUM REQUIREMENTS, REFERENCE INSTALLATION INSTRUCTIONS. 2. INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR THERMAL MOVEMENT. ALL ALUMINUM FLASHINGS MUST BE FASTENED 5" AWAY FROM THE 4" OVERLAP. 3. REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT REGARDING FASTENER TYPE & SPACING. (REFERENCE INSTALLATION INSTRUCTIONS & LOAD CHARTS FOR MIN. FASTENER REQUIREMENTS)
AutoCAD SHX Text
F = FINISH SIDE FV = FIELD VERIFY
AutoCAD SHX Text
NOTE:ALL FLASHING GAUGES TO BE ALL FLASHING GAUGES TO BE EQUAL TO THE ASSOCIATED PANEL GAUGE UNLESS NOTED OTHERWISE

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
GABLE DETAIL
AutoCAD SHX Text
SOLID SUBSTRATE
AutoCAD SHX Text
CLOSURE FLASHING
AutoCAD SHX Text
CLOSURE FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK
AutoCAD SHX Text
DRIP FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT. INSTALL MIN. 12" STRIP PLY OVER CLOSURE FLASHING, TOP LAYER TO BE PARALLEL WITH ROOF SLOPE.
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX. STAGGERED. PLACE A DAB OF CAULK AT FASTENER LOCATION. DRIVE FASTENER AND CAULK FASTENER HEADS
AutoCAD SHX Text
CLOSURE FLASHING
AutoCAD SHX Text
DRIP FLASHING
AutoCAD SHX Text
F
AutoCAD SHX Text
F
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
OPEN HEMS
AutoCAD SHX Text
POP RIVETS; 16" O.C. MAX.
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL, TURN UP INTO CLOSURE FLASHING, PANEL TO BE CONTINUOUS RIDGE TO EAVE
AutoCAD SHX Text
1. SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS MINIMUM REQUIREMENTS, REFERENCE INSTALLATION INSTRUCTIONS. 2. INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR THERMAL MOVEMENT. ALL ALUMINUM FLASHINGS MUST BE FASTENED 5" AWAY FROM THE 4" OVERLAP. 3. REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT REGARDING FASTENER TYPE & SPACING. (REFERENCE INSTALLATION INSTRUCTIONS & LOAD CHARTS FOR MIN. FASTENER REQUIREMENTS)
AutoCAD SHX Text
F = FINISH SIDE FV = FIELD VERIFY
AutoCAD SHX Text
NOTE:ALL FLASHING GAUGES TO BE ALL FLASHING GAUGES TO BE EQUAL TO THE ASSOCIATED PANEL GAUGE UNLESS NOTED OTHERWISE
AutoCAD SHX Text
NOTE: WHEN USING POP RIVETS ON FLASHING, STAINLESS STEEL RIVETS ARE REQUIRED WITH ALUMINUM PANELS. FLASHINGS MUST NOT BE FASTENED AT LAPS.
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-33C
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
F
AutoCAD SHX Text
OPEN HEM
AutoCAD SHX Text
12
AutoCAD SHX Text
SUB-FLASHING
AutoCAD SHX Text
COUNTER FLASHING
AutoCAD SHX Text
CAP FLASHING
AutoCAD SHX Text
F
AutoCAD SHX Text
OPEN HEM
AutoCAD SHX Text
1
AutoCAD SHX Text
12
AutoCAD SHX Text
1
AutoCAD SHX Text
F
AutoCAD SHX Text
ZEE CLOSURE
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT
AutoCAD SHX Text
MINIMUM SLOPE
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK BETWEEN ZEE CLOSURE AND CEE-LOCK PANEL
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIP
AutoCAD SHX Text
ZEE CLOSURE; REFER TO DETAIL CLA-23. CUT TO FIT BETWEEN SEAMS IF PANEL SEAMS ARE NOT PERPENDICULAR TO WALL.
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
COUNTER FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS. POP RIVET TO ZEE CLOSURE 16" O.C. MAX.
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; MIN. 3 PER ZEE CLOSURE
AutoCAD SHX Text
SUB-FLASHING 4" END LAPS WITH CONTINUOUS CAULK AT LAPS.
AutoCAD SHX Text
CAP FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS. POP RIVET TO CLEAT 16" O.C. MAX. CAULK ALL RIVET HEADS.
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT. INSTALL MIN. 12" STRIP PLY OVER SUB-FLASHING.
AutoCAD SHX Text
PARAPET DETAIL
AutoCAD SHX Text
SOLID SUBSTRATE
AutoCAD SHX Text
HEAD WALL
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
1. THIS DETAIL INTENDED FOR USE ON PARAPETS LESS THAN 12" IN HEIGHT, USE HEAD WALL DETAILS THIS DETAIL INTENDED FOR USE ON PARAPETS LESS THAN 12" IN HEIGHT, USE HEAD WALL DETAILS FOR ANY LARGER. 2. SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS MINIMUM REQUIREMENTS, REFERENCE INSTALLATION INSTRUCTIONS. 3. INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR THERMAL MOVEMENT. ALL ALUMINUM FLASHINGS MUST BE FASTENED 5" AWAY FROM THE 4" OVERLAP. 4. REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT REGARDING FASTENER TYPE & SPACING. (REFERENCE INSTALLATION INSTRUCTIONS & LOAD CHARTS FOR MIN. FASTENER REQUIREMENTS)
AutoCAD SHX Text
NOTE: WHEN USING POP RIVETS ON FLASHING, STAINLESS STEEL RIVETS ARE REQUIRED WITH ALUMINUM PANELS. FLASHINGS MUST NOT BE FASTENED AT LAPS.
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-40
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
F = FINISH SIDE FV = FIELD VERIFY
AutoCAD SHX Text
NOTE:ALL FLASHING GAUGES TO BE ALL FLASHING GAUGES TO BE EQUAL TO THE ASSOCIATED PANEL GAUGE UNLESS NOTED OTHERWISE

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
F
AutoCAD SHX Text
COUNTER FLASHING
AutoCAD SHX Text
SUB-FLASHING
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
COUNTER FLASHING: 4" END LAPS WITH CONTINUOUS CAULK AT LAPS.
AutoCAD SHX Text
SUB-FLASHING: 4" END LAPS WITH CONTINUOUS CAULK AT LAPS.
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT
AutoCAD SHX Text
12
AutoCAD SHX Text
MINIMUM SLOPE
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK
AutoCAD SHX Text
1
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL; FIELD CUT LAST PANEL AND FORM NEW LEG MIN. 4". PANEL TO BE CONTINUOUS FROM RIDGE TO EAVE.
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIP
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT. INSTALL MIN. 12" STRIP PLY OVER SUB-FLASHING, TOP LAYER TO BE PARALLEL WITH ROOF SLOPE
AutoCAD SHX Text
CAP FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS. POP RIVET TO CLEAT 16" O.C. MAX. CAULK ALL RIVET HEADS.
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX. PLACE A DAB OF CAULK AT FASTENER LOCATION DRIVE FASTENER AND CAULK FASTENER HEAD
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
12
AutoCAD SHX Text
CAP FLASHING
AutoCAD SHX Text
F
AutoCAD SHX Text
OPEN HEM
AutoCAD SHX Text
1
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
EXTRUDED VINYL WEATHERSEAL (OPTIONAL) US PATENT NO. 4,641,475.
AutoCAD SHX Text
1. THIS DETAIL INTENDED FOR USE ON PARAPETS LESS THAN 12" IN HEIGHT, USE RAKE WALL THIS DETAIL INTENDED FOR USE ON PARAPETS LESS THAN 12" IN HEIGHT, USE RAKE WALL DETAILS FOR ANY LARGER. 2. SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS MINIMUM REQUIREMENTS, REFERENCE INSTALLATION INSTRUCTIONS. 3. INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR THERMAL MOVEMENT. ALL ALUMINUM FLASHINGS MUST BE FASTENED 5" AWAY FROM THE 4" OVERLAP. 4. REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT REGARDING FASTENER TYPE & SPACING. (REFERENCE INSTALLATION INSTRUCTIONS & LOAD CHARTS FOR MIN. FASTENER REQUIREMENTS)
AutoCAD SHX Text
NOTE: WHEN USING POP RIVETS ON FLASHING, STAINLESS STEEL RIVETS ARE REQUIRED WITH ALUMINUM PANELS. FLASHINGS MUST NOT BE FASTENED AT LAPS.
AutoCAD SHX Text
PARAPET DETAIL
AutoCAD SHX Text
SOLID SUBSTRATE
AutoCAD SHX Text
RAKE WALL
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-41
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
F = FINISH SIDE FV = FIELD VERIFY
AutoCAD SHX Text
NOTE:ALL FLASHING GAUGES TO BE EQUAL TO THE ALL FLASHING GAUGES TO BE EQUAL TO THE ASSOCIATED PANEL GAUGE UNLESS NOTED OTHERWISE

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
HEAD WALL DETAIL
AutoCAD SHX Text
SOLID SUBSTRATE
AutoCAD SHX Text
RECIEVER FLASHING
AutoCAD SHX Text
F
AutoCAD SHX Text
OPEN HEM
AutoCAD SHX Text
SUB-FLASHING
AutoCAD SHX Text
COUNTER FLASHING
AutoCAD SHX Text
F
AutoCAD SHX Text
ZEE CLOSURE
AutoCAD SHX Text
RECEIVER & COUNTER FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS POP RIVET 16" O.C. MAX. CAULK RIVET HEADS
AutoCAD SHX Text
COUNTER FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS POP RIVET TO ZEE CLOSURE 16" O.C. MAX.
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIP
AutoCAD SHX Text
SUB-FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK BETWEEN ZEE CLOSURE AND CEE-LOCK PANEL
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
ZEE CLOSURE; REFER TO DETAIL CLA-23. CUT TO FIT BETWEEN SEAMS IF PANEL SEAMS ARE NOT PERPENDICULAR TO WALL.
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT. INSTALL MIN. 12" STRIP PLY OVER SUB-FLASHING.
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
BERRIDGE WALL PANEL OR FASCIA PANEL
AutoCAD SHX Text
F
AutoCAD SHX Text
COUNTER FLASHING
AutoCAD SHX Text
RECIEVER FLASHING
AutoCAD SHX Text
OPEN HEM
AutoCAD SHX Text
F
AutoCAD SHX Text
1. SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS MINIMUM REQUIREMENTS, REFERENCE INSTALLATION INSTRUCTIONS. 2. INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR THERMAL MOVEMENT. ALL ALUMINUM FLASHINGS MUST BE FASTENED 5" AWAY FROM THE 4" OVERLAP. 3. REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT REGARDING FASTENER TYPE & SPACING. (REFERENCE INSTALLATION INSTRUCTIONS & LOAD CHARTS FOR MIN. FASTENER REQUIREMENTS)
AutoCAD SHX Text
NOTE: WHEN USING POP RIVETS ON FLASHING, STAINLESS STEEL RIVETS ARE REQUIRED WITH ALUMINUM PANELS. FLASHINGS MUST NOT BE FASTENED AT LAPS.
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-51PS
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
F = FINISH SIDE FV = FIELD VERIFY
AutoCAD SHX Text
NOTE:ALL FLASHING GAUGES TO BE ALL FLASHING GAUGES TO BE EQUAL TO THE ASSOCIATED PANEL GAUGE UNLESS NOTED OTHERWISE
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; MIN. 3 PER ZEE CLOSURE

F

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
F
AutoCAD SHX Text
OPEN HEM
AutoCAD SHX Text
SUB-FLASHING
AutoCAD SHX Text
COUNTER FLASHING
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK BETWEEN ZEE CLOSURE AND CEE-LOCK PANEL
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; MIN. 3 PER ZEE CLOSURE
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIP
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL
AutoCAD SHX Text
COUNTERFLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS POP RIVET TO ZEE CLOSURE 16" O.C. MAX.
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
REGLET FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS
AutoCAD SHX Text
CONTINUOUS CAULK AT REGLET
AutoCAD SHX Text
REGLET; BELOW WEEP HOLES
AutoCAD SHX Text
SUB-FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT
AutoCAD SHX Text
REGLET FLASHING
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT. INSTALL MIN. 12" STRIP PLY OVER SUB-FLASHING.
AutoCAD SHX Text
ZEE CLOSURE; REFER TO DETAIL CLA-23. CUT TO FIT BETWEEN SEAMS IF PANEL SEAMS ARE NOT PERPENDICULAR TO WALL.
AutoCAD SHX Text
F
AutoCAD SHX Text
ZEE CLOSURE
AutoCAD SHX Text
1. SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS MINIMUM REQUIREMENTS, REFERENCE INSTALLATION INSTRUCTIONS. 2. INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR THERMAL MOVEMENT. ALL ALUMINUM FLASHINGS MUST BE FASTENED 5" AWAY FROM THE 4" OVERLAP. 3. REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT REGARDING FASTENER TYPE & SPACING. (REFERENCE INSTALLATION INSTRUCTIONS & LOAD CHARTS FOR MIN. FASTENER REQUIREMENTS)
AutoCAD SHX Text
NOTE: WHEN USING POP RIVETS ON FLASHING, STAINLESS STEEL RIVETS ARE REQUIRED WITH ALUMINUM PANELS. FLASHINGS MUST NOT BE FASTENED AT LAPS.
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-51R
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
F = FINISH SIDE FV = FIELD VERIFY
AutoCAD SHX Text
NOTE:ALL FLASHING GAUGES TO BE ALL FLASHING GAUGES TO BE EQUAL TO THE ASSOCIATED PANEL GAUGE UNLESS NOTED OTHERWISE
AutoCAD SHX Text
HEAD WALL DETAIL
AutoCAD SHX Text
SOLID SUBSTRATE
AutoCAD SHX Text
REGLET

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
CONTINUOUS CAULK
AutoCAD SHX Text
LONG LIFE STAINLESS STEEL FASTENERS WITH NEOPRENE WASHERS; 16" O.C. MAX.
AutoCAD SHX Text
CONTINUOUS CAULK
AutoCAD SHX Text
LONG LIFE STAINLESS STEEL FASTENERS WITH NEOPRENE WASHERS; 16" O.C. MAX.
AutoCAD SHX Text
SURFACE FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS.
AutoCAD SHX Text
COUNTER FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS POP RIVET TO ZEE CLOSURE 16" O.C.; CAULK RIVET HEADS
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIP
AutoCAD SHX Text
ZEE CLOSURE; CUT TO FIT BETWEEN SEAMS USE CLA-23
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
CONTINUOUS TAPE SEAL
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK BETWEEN ZEE CLOSURE AND CEE-LOCK PANEL
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; MIN. 3 PER ZEE CLOSURE
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
SUB-FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS
AutoCAD SHX Text
F
AutoCAD SHX Text
OPEN HEM
AutoCAD SHX Text
SUB-FLASHING
AutoCAD SHX Text
COUNTER FLASHING
AutoCAD SHX Text
F
AutoCAD SHX Text
ZEE CLOSURE
AutoCAD SHX Text
SURFACE FLASHING
AutoCAD SHX Text
F
AutoCAD SHX Text
CONTINUOUS TAPE SEAL
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT. INSTALL MIN. 12" STRIP PLY OVER SUB-FLASHING.
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-51SM
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
HEAD WALL DETAIL
AutoCAD SHX Text
SOLID SUBSTRATE
AutoCAD SHX Text
SURFACE MOUNT
AutoCAD SHX Text
1. SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS MINIMUM REQUIREMENTS, REFERENCE INSTALLATION INSTRUCTIONS. 2. INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR THERMAL MOVEMENT. ALL ALUMINUM FLASHINGS MUST BE FASTENED 5" AWAY FROM THE 4" OVERLAP. 3. REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT REGARDING FASTENER TYPE & SPACING. (REFERENCE INSTALLATION INSTRUCTIONS & LOAD CHARTS FOR MIN. FASTENER REQUIREMENTS)
AutoCAD SHX Text
NOTE: WHEN USING POP RIVETS ON FLASHING, STAINLESS STEEL RIVETS ARE REQUIRED WITH ALUMINUM PANELS. FLASHINGS MUST NOT BE FASTENED AT LAPS.
AutoCAD SHX Text
F = FINISH SIDE FV = FIELD VERIFY
AutoCAD SHX Text
NOTE:ALL FLASHING GAUGES TO BE ALL FLASHING GAUGES TO BE EQUAL TO THE ASSOCIATED PANEL GAUGE UNLESS NOTED OTHERWISE

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX. PLACE A DAB OF CAULK AT FASTENER LOCATION DRIVE FASTENER AND CAULK FASTENER HEAD
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
SUB-FLASHING 4" END LAPS WITH CONTINUOUS CAULK AT LAPS
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK
AutoCAD SHX Text
RECEIVER & COUNTER FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS POP RIVET 16" O.C. CAULK RIVET HEADS
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT. INSTALL MIN. 12" STRIP PLY OVER SUB-FLASHING. TOP LAYER TO BE PARALLEL WITH ROOF SLOPE.
AutoCAD SHX Text
BERRIDGE WALL PANEL OR FASCIA PANEL
AutoCAD SHX Text
F
AutoCAD SHX Text
COUNTER FLASHING
AutoCAD SHX Text
RECIEVER FLASHING
AutoCAD SHX Text
OPEN HEM
AutoCAD SHX Text
F
AutoCAD SHX Text
SUB-FLASHING
AutoCAD SHX Text
NOTE: WHEN USING POP RIVETS ON FLASHING, STAINLESS STEEL RIVETS ARE REQUIRED WITH ALUMINUM PANELS. FLASHINGS MUST NOT BE FASTENED AT LAPS.
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL; FIELD CUT LAST PANEL AND FORM NEW LEG MIN. 4". PANEL TO BE CONTINUOUS FROM RIDGE TO EAVE.
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIP
AutoCAD SHX Text
EXTRUDED VINYL WEATHERSEAL (OPTIONAL) US PATENT NO. 4,641,475.
AutoCAD SHX Text
HEAD WALL DETAIL
AutoCAD SHX Text
SOLID SUBSTRATE
AutoCAD SHX Text
RECIEVER FLASHING
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-53PS
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
1. SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS MINIMUM REQUIREMENTS, REFERENCE INSTALLATION INSTRUCTIONS. 2. INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR THERMAL MOVEMENT. ALL ALUMINUM FLASHINGS MUST BE FASTENED 5" AWAY FROM THE 4" OVERLAP. 3. REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT REGARDING FASTENER TYPE & SPACING. (REFERENCE INSTALLATION INSTRUCTIONS & LOAD CHARTS FOR MIN. FASTENER REQUIREMENTS)
AutoCAD SHX Text
F = FINISH SIDE FV = FIELD VERIFY
AutoCAD SHX Text
NOTE:ALL FLASHING GAUGES TO BE ALL FLASHING GAUGES TO BE EQUAL TO THE ASSOCIATED PANEL GAUGE UNLESS NOTED OTHERWISE

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
REGLET; BELOW WEEP HOLES
AutoCAD SHX Text
CONTINUOUS CAULK AT REGLET
AutoCAD SHX Text
SUB-FLASHING: 4" END LAPS WITH CONTINUOUS CAULK AT LAPS
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK
AutoCAD SHX Text
BERRIDGE APPROVED PEEL AND STICK UNDERLAYMENT
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
REGLET FLASHING
AutoCAD SHX Text
F
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL; FIELD CUT LAST PANEL AND FORM NEW LEG MIN. 4". PANEL TO BE CONTINUOUS FROM RIDGE TO EAVE.
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIP
AutoCAD SHX Text
REGLET FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT. INSTALL MIN. 12" STRIP PLY OVER SUB-FLASHING, TOP LAYER TO BE PARALLEL WITH ROOF SLOPE
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX. PLACE A DAB OF CAULK AT FASTENER LOCATION DRIVE FASTENER AND CAULK FASTENER HEAD
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
SUB-FLASHING
AutoCAD SHX Text
EXTRUDED VINYL WEATHERSEAL (OPTIONAL) US PATENT NO. 4,641,475.
AutoCAD SHX Text
NOTE: WHEN USING POP RIVETS ON FLASHING, STAINLESS STEEL RIVETS ARE REQUIRED WITH ALUMINUM PANELS. FLASHINGS MUST NOT BE FASTENED AT LAPS.
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-53R
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
HEAD WALL DETAIL
AutoCAD SHX Text
SOLID SUBSTRATE
AutoCAD SHX Text
REGLET
AutoCAD SHX Text
1. SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS MINIMUM REQUIREMENTS, REFERENCE INSTALLATION INSTRUCTIONS. 2. INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR THERMAL MOVEMENT. ALL ALUMINUM FLASHINGS MUST BE FASTENED 5" AWAY FROM THE 4" OVERLAP. 3. REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT REGARDING FASTENER TYPE & SPACING. (REFERENCE INSTALLATION INSTRUCTIONS & LOAD CHARTS FOR MIN. FASTENER REQUIREMENTS)
AutoCAD SHX Text
F = FINISH SIDE FV = FIELD VERIFY
AutoCAD SHX Text
NOTE:ALL FLASHING GAUGES TO BE ALL FLASHING GAUGES TO BE EQUAL TO THE ASSOCIATED PANEL GAUGE UNLESS NOTED OTHERWISE

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-53SM
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
HEAD WALL DETAIL
AutoCAD SHX Text
SOLID SUBSTRATE
AutoCAD SHX Text
SURFACE MOUNT
AutoCAD SHX Text
SUB-FLASHING: 4" END LAPS WITH CONTINUOUS CAULK AT LAPS
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL; FIELD CUT LAST PANEL AND FORM NEW LEG MIN. 4". PANEL TO BE CONTINUOUS FROM RIDGE TO EAVE.
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIP
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT. INSTALL MIN. 12" STRIP PLY OVER SUB-FLASHING, TOP LAYER TO BE PARALLEL WITH ROOF SLOPE
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX. PLACE A DAB OF CAULK AT FASTENER LOCATION DRIVE FASTENER AND CAULK FASTENER HEAD
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
SUB-FLASHING
AutoCAD SHX Text
F
AutoCAD SHX Text
COUNTER FLASHING
AutoCAD SHX Text
SURFACE FLASHING
AutoCAD SHX Text
F
AutoCAD SHX Text
SURFACE FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS.
AutoCAD SHX Text
CONTINUOUS CAULK
AutoCAD SHX Text
LONG LIFE STAINLESS STEEL FASTENERS WITH NEOPRENE WASHERS; 16" O.C. MAX.
AutoCAD SHX Text
CONTINUOUS CAULK
AutoCAD SHX Text
LONG LIFE STAINLESS STEEL FASTENERS WITH NEOPRENE WASHERS; 16" O.C. MAX.
AutoCAD SHX Text
CONTINUOUS TAPE SEAL
AutoCAD SHX Text
CONTINUOUS TAPE SEAL
AutoCAD SHX Text
COUNTER FLASHING; 4" END LAPS WITH CONTINUOUS CAULK AT LAPS
AutoCAD SHX Text
EXTRUDED VINYL WEATHERSEAL (OPTIONAL) US PATENT NO. 4,641,475.
AutoCAD SHX Text
NOTE: WHEN USING POP RIVETS ON FLASHING, STAINLESS STEEL RIVETS ARE REQUIRED WITH ALUMINUM PANELS. FLASHINGS MUST NOT BE FASTENED AT LAPS.
AutoCAD SHX Text
1. SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS MINIMUM REQUIREMENTS, REFERENCE INSTALLATION INSTRUCTIONS. 2. INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR THERMAL MOVEMENT. ALL ALUMINUM FLASHINGS MUST BE FASTENED 5" AWAY FROM THE 4" OVERLAP. 3. REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT REGARDING FASTENER TYPE & SPACING. (REFERENCE INSTALLATION INSTRUCTIONS & LOAD CHARTS FOR MIN. FASTENER REQUIREMENTS)
AutoCAD SHX Text
F = FINISH SIDE FV = FIELD VERIFY
AutoCAD SHX Text
NOTE:ALL FLASHING GAUGES TO BE ALL FLASHING GAUGES TO BE EQUAL TO THE ASSOCIATED PANEL GAUGE UNLESS NOTED OTHERWISE

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
F
AutoCAD SHX Text
OPEN HEM
AutoCAD SHX Text
SUB-FLASHING
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
TRANSITION FLASHING
AutoCAD SHX Text
SLOPE TRANSITION DETAIL
AutoCAD SHX Text
SOLID SUBSTRATE
AutoCAD SHX Text
12
AutoCAD SHX Text
1
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
FIELD CUT VERTICAL LEG OF PANEL AND FORM HEM, HOOK ON TO CLEAT
AutoCAD SHX Text
1 ON 12 MINIMUM SLOPE AWAY FORM CLEAT
AutoCAD SHX Text
TRANSITION FLASHING: 4" END LAPS WITH CONTINUOUS CAULK AT LAPS. POP RIVET TO ZEE CLOSURE 16" O.C. MAX. CAULK RIVET HEADS
AutoCAD SHX Text
STAINLESS STEEL FASTENERS: MINIMUM 3 PER ZEE CLOSURE
AutoCAD SHX Text
NOTE: PLACE A DAB OF CAULK AT CLEAT FASTENER LOCATION, DRIVE FASTENER THROUGH CAULK, AND CAULK FASTENER HEADS. DO NOT: RUN A CONTINUOUS BEAD OF CAULK ON CLEAT OR UNDER CLEAT
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK BETWEEN ZEE CLOSURE AND ROOF PANEL
AutoCAD SHX Text
SUB-FLASHING: 4" END LAPS WITH CONTINUOUS CAULK AT LAPS
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT. INSTALL 36" OR FULL ROLL STRIP PLY OVER TRANSITION FLASHING.
AutoCAD SHX Text
STAINLESS STEEL FASTENERS; 16" O.C. MAX.
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIPS
AutoCAD SHX Text
ZEE CLOSURE; REFER TO DETAIL CLA-23
AutoCAD SHX Text
NOTE: WHEN USING POP RIVETS ON FLASHING, STAINLESS STEEL RIVETS ARE REQUIRED WITH ALUMINUM PANELS. FLASHINGS MUST NOT BE FASTENED AT LAPS.
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-61
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
1. SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS MINIMUM REQUIREMENTS, REFERENCE INSTALLATION INSTRUCTIONS. 2. INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR THERMAL MOVEMENT. ALL ALUMINUM FLASHINGS MUST BE FASTENED 5" AWAY FROM THE 4" OVERLAP. 3. REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT REGARDING FASTENER TYPE & SPACING. (REFERENCE INSTALLATION INSTRUCTIONS & LOAD CHARTS FOR MIN. FASTENER REQUIREMENTS)
AutoCAD SHX Text
F = FINISH SIDE FV = FIELD VERIFY
AutoCAD SHX Text
NOTE:ALL FLASHING GAUGES TO BE ALL FLASHING GAUGES TO BE EQUAL TO THE ASSOCIATED PANEL GAUGE UNLESS NOTED OTHERWISE

F

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
CUT PANEL SEAM BACK, TURN PANEL PAN UNDER AND HOOK PANEL PAN ONTO VALLEY FLASHING.
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL
AutoCAD SHX Text
2 STAINLESS STEEL CEE-LOCK CLIPS ABOVE VALLEY FLASHING
AutoCAD SHX Text
DO NOT USE FASTENERS IN STAINLESS STEEL CEE-LOCK CLIPS OVER VALLEY FLASHING.
AutoCAD SHX Text
CONTINUOUS CLEAT; WITH STAINLESS STEEL FASTENERS 16" O.C. MAX.
AutoCAD SHX Text
FIELD CUT PANEL SEAM AND FORM PANEL PAN AROUND CLEAT OF VALLEY FLASHING, DO NOT RUN CAULK IN OR ON CLEAT OF VALLEY FLASHING
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
VALLEY FLASHING; 12" END LAPS WITH 2 CONTINUOUS BEAD OF CAULK AT LAPS
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK BETWEEN VALLEY FLASHING AND PEEL & STICK UNDERLAYMENT
AutoCAD SHX Text
SEE DETAIL CLA-71 FOR VALLEY FLASHING LAPPING
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT. INSTALL 36" OR FULL ROLL STRIP PLY OVER VALLEY FLASHING.
AutoCAD SHX Text
OPEN HEM
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
VALLEY FLASHING
AutoCAD SHX Text
OPEN HEM
AutoCAD SHX Text
FORM VALLEY FLASHING FROM A FULL 42" OR 48" WIDE FLAT SHEET. SEE TAPERED VALLEY DETAIL CLA-73A
AutoCAD SHX Text
VALLEY DETAIL
AutoCAD SHX Text
SOLID SUBSTRATE
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-70
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
1. SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS MINIMUM REQUIREMENTS, REFERENCE INSTALLATION INSTRUCTIONS. 2. INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR THERMAL MOVEMENT. ALL ALUMINUM FLASHINGS MUST BE FASTENED 5" AWAY FROM THE 4" OVERLAP. 3. REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT REGARDING FASTENER TYPE & SPACING. (REFERENCE INSTALLATION INSTRUCTIONS & LOAD CHARTS FOR MIN. FASTENER REQUIREMENTS)
AutoCAD SHX Text
F = FINISH SIDE FV = FIELD VERIFY
AutoCAD SHX Text
NOTE:ALL FLASHING GAUGES TO BE ALL FLASHING GAUGES TO BE EQUAL TO THE ASSOCIATED PANEL GAUGE UNLESS NOTED OTHERWISE

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
VALLEY FLASHING: 12" END LAPS WITH 2 CONTINUOUS BEADS OF CAULK AT LAPS
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
STAINLESS STEEL FASTENERS THROUGH VALLEY ONLY AT TOP OF FLASHING UNDER LAP, NO FASTENERS ARE TO BE EXPOSED ON TOP (OVERLAPPING) VALLEY
AutoCAD SHX Text
2 CONTINUOUS BEADS OF CAULK AT LAPS
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
FIELD CUT PANEL SEAM AND FORM PANEL PAN AROUND CLEAT OF VALLEY FLASHING
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIPS. DO NOT RUN FASTENERS THRU VALLEY FLASHING START FIRST FASTENER BEHIND VALLEY FLASHING
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK BETWEEN VALLEY FLASHING AND UNDERLAYMENT (CAULK NOT REQUIRED FOR PEEL AND STICK)
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT. INSTALL 36" OR FULL ROLL STRIP PLY.
AutoCAD SHX Text
VALLEY DETAIL ISOMETRIC
AutoCAD SHX Text
SOLID SUBSTRATE
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-71
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
TAPERED VALLEY DETAIL
AutoCAD SHX Text
WITHOUT DIVERTER
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-73A
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
SMALL END
AutoCAD SHX Text
LARGE END
AutoCAD SHX Text
SMALL END
AutoCAD SHX Text
START POINT
AutoCAD SHX Text
LARGE END
AutoCAD SHX Text
NOTE: WHEN VALLEY FLASHING DIMENSIONS ARE LAID OUT ON FLAT SHEET YOU MUST START FROM CENTER OF FLAT SHEET AND MARK OUT THE DIMENSIONS TO BOTH OUTER SIDES OF THE FLAT SHEET
AutoCAD SHX Text
NOTE: WHEN VALLEY FLASHING DIMENSIONS ARE LAID OUT ON FLAT SHEET YOU MUST START FROM CENTER OF FLAT SHEET AND MARK OUT THE DIMENSIONS TO BOTH OUTER SIDES OF THE FLAT SHEET
AutoCAD SHX Text
START POINT
AutoCAD SHX Text
START POINT
AutoCAD SHX Text
START POINT
AutoCAD SHX Text
%%U FOR USE WITH 42" FLAT SHEET
AutoCAD SHX Text
%%U FOR USE WITH 48" FLAT SHEET

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
1. PIPE PENETRATION TO BE IN PAN OF PANEL ONLY PIPE PENETRATION TO BE IN PAN OF PANEL ONLY 2. FIELD CUT HOLE IN PANEL 1" LESS THAN DIA. OF STACK. BACK CUT HOLE AND FIELD CUT HOLE IN PANEL 1" LESS THAN DIA. OF STACK. BACK CUT HOLE AND BEND PANEL UP AROUND STACK. CAULK CONTINUOUS. 3. IF PANELS ARE 30' OR LONGER, CUT HOLE TO ALLOW FOR THERMAL MOVEMENT. IF PANELS ARE 30' OR LONGER, CUT HOLE TO ALLOW FOR THERMAL MOVEMENT. 4. IF PIPE IS METAL, IT MUST BE PAINTED TO PREVENT RUST RUN-OFF FROM IF PIPE IS METAL, IT MUST BE PAINTED TO PREVENT RUST RUN-OFF FROM STAINING PANELS.
AutoCAD SHX Text
ROOF PIPE PENETRATION OF 4" IN DIA. OR LESS
AutoCAD SHX Text
RUBBERIZED BOOT FLASHING
AutoCAD SHX Text
CONTINUOUS CAULK
AutoCAD SHX Text
PIPE PENETRATION TO BE IN PAN OF PANEL ONLY
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL
AutoCAD SHX Text
CUT PANEL 1" SMALLER THAN PENETRATION, BACK CUT TABS, FOLD TABS UP AROUND PENETRATION, AND CAULK.
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
SET RUBBERIZED BOOT INTO CONTINUOUS BEAD OF CAULK. USE STAINLESS STEEL FASTENERS AS SPECIFIED BY BOOT MANUFACTURER CAULK FASTENER HEADS
AutoCAD SHX Text
STAINLESS STEEL HOSE CLAMP
AutoCAD SHX Text
CONTINUOUS CAULK
AutoCAD SHX Text
IN PAN OF PANEL ONLY
AutoCAD SHX Text
(PREFERRED METHOD)
AutoCAD SHX Text
PIPE PENETRATION
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT
AutoCAD SHX Text
SOLID SUBSTRATE
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-80
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
ANGLE FLASHING
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
ZEE CLOSURE
AutoCAD SHX Text
SEE DETAIL BELOW
AutoCAD SHX Text
COUNTER FLASHING
AutoCAD SHX Text
DO NOT: RUN CAULK ON OR UNDER CONTINUOUS CLEAT
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
ANGLE FLASHING
AutoCAD SHX Text
ROOF CURB
AutoCAD SHX Text
COUNTERFLASHING: EXTEND 1/4" BEYOND ZEE CLOSURE (FLASHING CUT AWAY FOR CLARITY)
AutoCAD SHX Text
CLA-82
AutoCAD SHX Text
CLA-83
AutoCAD SHX Text
SQUARE PENETRATION
AutoCAD SHX Text
PLAN VIEW
AutoCAD SHX Text
SOLID SUBSTRATE
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL SEAM
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL; FIELD BEND TO CURB
AutoCAD SHX Text
ZEE CLOSURE; CUT 2" OFF HORIZONTAL LEGS, BEND VERTICAL LEG AND SLIP BETWEEN CEE-LOCK PANELS, CAULK BETWEEN ZEE CLOSURE, COUNTER FLASHING AND PANEL
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL SEAM
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL SEAM
AutoCAD SHX Text
UPPER CEE-LOCK PANEL; FIELD BEND TO CURB
AutoCAD SHX Text
LOWER CEE-LOCK PANEL; FIELD BEND TO CURB
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-81
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
SQUARE PENETRATION
AutoCAD SHX Text
SECTION A
AutoCAD SHX Text
CURB MATERIAL
AutoCAD SHX Text
SUB-FLASHING
AutoCAD SHX Text
COUNTERFLASHING; POP RIVET TO ZEE CLOSURE 16" O.C. MAX.
AutoCAD SHX Text
SUB-FLASHING
AutoCAD SHX Text
FLASHING
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
PLACE A DAB OF CAULK AT FASTENER LOCATIONS. DRIVE FASTENER AND CAULK FASTENER HEAD
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK. NOT REQUIRED WITH PEEL AND STICK UNDERLAYMENT
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK BETWEEN ZEE CLOSURE, ROOF PANEL, AND SEAM
AutoCAD SHX Text
NOTE: DO NOT RUN A CONTINUOUS BEAD OF CAULK IN CLEAT OR UNDER CLEAT.
AutoCAD SHX Text
STAINLESS STEEL FASTENERS: MIN. 3 PER BETWEEN ZEE CLOSURE
AutoCAD SHX Text
F
AutoCAD SHX Text
F
AutoCAD SHX Text
F
AutoCAD SHX Text
OPEN HEM
AutoCAD SHX Text
COUNTER FLASHING
AutoCAD SHX Text
SUB-FLASHING
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
FLASHING BY OTHERS
AutoCAD SHX Text
STAINLESS STEEL CEE-LOCK CLIPS
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT. INSTALL 36" OR FULL ROLL STRIP PLY OVER THE FLASHING.
AutoCAD SHX Text
ZEE CLOSURE; SEE DETAIL CLA-23
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL
AutoCAD SHX Text
F
AutoCAD SHX Text
ZEE CLOSURE
AutoCAD SHX Text
SOLID SUBSTRATE
AutoCAD SHX Text
1. SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS MINIMUM REQUIREMENTS, REFERENCE INSTALLATION INSTRUCTIONS. 2. INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR THERMAL MOVEMENT. ALL ALUMINUM FLASHINGS MUST BE FASTENED 5" AWAY FROM THE 4" OVERLAP. 3. REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT REGARDING FASTENER TYPE & SPACING. (REFERENCE INSTALLATION INSTRUCTIONS & LOAD CHARTS FOR MIN. FASTENER REQUIREMENTS)
AutoCAD SHX Text
NOTE: WHEN USING POP RIVETS ON FLASHING, STAINLESS STEEL RIVETS ARE REQUIRED WITH ALUMINUM PANELS. FLASHINGS MUST NOT BE FASTENED AT LAPS.
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-82
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
F = FINISH SIDE FV = FIELD VERIFY
AutoCAD SHX Text
NOTE:ALL FLASHING GAUGES TO BE ALL FLASHING GAUGES TO BE EQUAL TO THE ASSOCIATED PANEL GAUGE UNLESS NOTED OTHERWISE

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
WRAP FLASHING
AutoCAD SHX Text
SUB-FLASHING
AutoCAD SHX Text
WRAP PERIMETER WITH UNDERLAYMENT AND SUB-FLASHING
AutoCAD SHX Text
FLASHING BY OTHERS
AutoCAD SHX Text
CURB MATERIAL
AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL RAKE WALL CURB FLASHING; FIELD FORM TO CURB.
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT
AutoCAD SHX Text
SQUARE PENETRATION
AutoCAD SHX Text
SECTION B
AutoCAD SHX Text
SOLID SUBSTRATE
AutoCAD SHX Text
1. SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS SOLID SHEATHING (NOT BY BERRIDGE) TO MEET ENGINEERING AND ARCHITECTURAL SPECIFICATIONS MINIMUM REQUIREMENTS, REFERENCE INSTALLATION INSTRUCTIONS. 2. INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR INSTALL ALUMINUM FLASHINGS WITH A 1/4" GAP BETWEEN NOTCH AND OVERLAP IN THE LAPS FOR THERMAL MOVEMENT. ALL ALUMINUM FLASHINGS MUST BE FASTENED 5" AWAY FROM THE 4" OVERLAP. 3. REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT REFERENCE BERRIDGE'S WEB SITE FOR APPROVED UNDERLAYMENT AND CAULK TYPES CONSULT BERRIDGE MANUFACTURING'S ENGINEERING DEPARTMENT REGARDING FASTENER TYPE & SPACING. (REFERENCE INSTALLATION INSTRUCTIONS & LOAD CHARTS FOR MIN. FASTENER REQUIREMENTS)
AutoCAD SHX Text
NOTE: WHEN USING POP RIVETS ON FLASHING, STAINLESS STEEL RIVETS ARE REQUIRED WITH ALUMINUM PANELS. FLASHINGS MUST NOT BE FASTENED AT LAPS.
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-83
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL
AutoCAD SHX Text
F = FINISH SIDE FV = FIELD VERIFY
AutoCAD SHX Text
NOTE:ALL FLASHING GAUGES TO BE ALL FLASHING GAUGES TO BE EQUAL TO THE ASSOCIATED PANEL GAUGE UNLESS NOTED OTHERWISE

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
DO NOT RUN CONTINUOUS CAULK IN OR UNDER CLEAT
AutoCAD SHX Text
FLASHING
AutoCAD SHX Text
CLEAT
AutoCAD SHX Text
ZEE CLOSURE; CUT AND BEND AT END AND CAULK
AutoCAD SHX Text
SEE DETAIL BELOW
AutoCAD SHX Text
ANGLE FLASHING
AutoCAD SHX Text
ANGLE FLASHING
AutoCAD SHX Text
UPPER PANEL
AutoCAD SHX Text
LOWER PANEL
AutoCAD SHX Text
CLEAT
AutoCAD SHX Text
ZEE CLOSURE
AutoCAD SHX Text
COUNTER FLASHING; EXTEND 1/4" BEYOND ZEE CLOSURE (CUT AWAY VIEW FOR CLARITY)
AutoCAD SHX Text
CONTINUOUS BEAD OF CAULK BETWEEN ZEE CLOSURE AND PANEL
AutoCAD SHX Text
SQUARE PENETRATION
AutoCAD SHX Text
ISOMETRIC
AutoCAD SHX Text
SOLID SUBSTRATE
AutoCAD SHX Text
FOR ROOF PENETRATIONS LARGER THAN 4" SQUARE OR ROUND
AutoCAD SHX Text
CEE-LOCK PANEL FIELD BEND TO CURB
AutoCAD SHX Text
HEM PANEL PAN UNDER BOTH SIDES OF PENETRATION
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-84
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
SOLID SHEATHING
AutoCAD SHX Text
BERRIDGE PANEL SYSTEM
AutoCAD SHX Text
LIGHTNING ROD (NOT BY BERRIDGE)
AutoCAD SHX Text
USE ONLY STAINLESS STEEL OR ALUMINUM LIGHTNING RODSONLY STAINLESS STEEL OR ALUMINUM LIGHTNING RODS STAINLESS STEEL OR ALUMINUM LIGHTNING RODS
AutoCAD SHX Text
STAINLESS STEEL WASHER SET IN CAULK
AutoCAD SHX Text
SET RUBBERIZED BOOT INTO CONTINUOUS BEAD OF CAULK. DO NOT USE FASTENERS IN BOOT FLASHING
AutoCAD SHX Text
CONTINUOUS CAULK
AutoCAD SHX Text
LIGHTNING CONTROL SYSTEMS ON A PROJECT ARE TO THE DISCRETION OF THE ARCHITECT OR PROJECT DESIGNER. BERRIDGE MANUFACTURING CO. MAKES NO RECOMMENDATIONS AS TO WHEN TO USE A LIGHTNING CONTROL SYSTEM. IF A LIGHTNING CONTROL SYSTEM IS SPECIFIED, ALL COMPONENTS OF THE SYSTEM SHOULD BE OF MATERIAL COMPATIBLE WITH THE BERRIDGE ROOFING SYSTEM; ALUMINUM AND/OR STAINLESS STEEL ARE TWO METALS THAT WORK WELL. WHEN AN INCOMPATIBLE MATERIAL SUCH AS COPPER IS USED ELECTROLYTIC CORROSION OCCURS DUE TO DISSIMILAR METALS CONTACTING IN THE PRESENCE OF AN ELECTROLYTE, SUCH AS WATER. THE DISSIMILAR METALS SET UP A GALVANIC ACTION THAT RESULT IN THE DETERIORATION OF ONE OF THEM. BERRIDGE MANUFACTURING CO. WILL NOT BE HELD LIABLE FOR ANY CLAIMS DUE TO FAILURES CAUSED BY DISSIMILAR METALS. LIGHTNING CONTROL SYSTEMS NORMALLY REQUIRE ANCHORAGE FOR THE AIR TERMINALS AND THE CABLE BASES. IF ANCHORAGE TO BERRIDGE MATERIAL IS MADE WITH AN ADHESIVE, COMPATIBILITY TO KYNAR/HYLAR PAINT SHOULD BE INVESTIGATED. IF CUTTING HOLES IN THE BERRIDGE ROOFING SYSTEM IS REQUIRED FOR ANCHORAGE, RUBBERIZED BOOTS (REFER TO THE LIGHTNING CONTROL MANUFACTURER FOR SUITABLE BOOTS) SHOULD BE USED AND SEALED TO THE BERRIDGE ROOF SYSTEM WITH TREMCO SPECTREM ONE CAULKING. IT IS POSSIBLE THAT CABLES MAY VIBRATE IN WIND AND CAUSE DAMAGE TO THE METAL AND PAINT FINISH, THEREFORE CABLES SHOULD NOT BE ALLOWED TO LAY ON TOP OF THE ROOFING PANELS OR FLASHING. BERRIDGE MANUFACTURING WILL NOT BE RESPONSIBLE FOR WATERTIGHTNESS OF THE LIGHTNING CONTROL SYSTEM AND SHOULD BE COVERED BY THE LIGHTNING CONTROL SYSTEM INSTALLER OR MANUFACTURER. LIGHTNING CONTROL SYSTEMS ARE TO BE DESIGNED BY AND INSTALLED BY QUALIFIED PROFESSIONALS. BERRIDGE MANUFACTURING CO. SHALL HAVE NO LIABILITY TO THE RECOMMENDATIONS OUTLINED IN THIS LETTER.
AutoCAD SHX Text
BERRIDGE APPROVED PEEL & STICK UNDERLAYMENT
AutoCAD SHX Text
LIGHTNING ROD
AutoCAD SHX Text
(IF APPLICABLE)
AutoCAD SHX Text
RUBBERIZED "BOOT" FLASHING (NOT BY BERRIDGE)
AutoCAD SHX Text
FILL INSIDE OF BOOT WITH CAULK
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-89
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
UL 90 APPROVED ASSEMBLY ALUMINUM CEE-LOCK PANEL WITH STAINLESS STEEL CLIPS THROUGH 6" RIGID INSULATION BOARD AND INTO 22 GA. STRUCTURAL METAL DECK UL CONSTRUCTION NO. 689
AutoCAD SHX Text
1. BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL * - 0.032" COATED BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL * - 0.032" COATED ALUMINUM, 16 " WIDE, 1 " HIGH PANELS CONTINUOUS OVER TWO OR MORE SPANS WITHOUT 12" WIDE, 1 " HIGH PANELS CONTINUOUS OVER TWO OR MORE SPANS WITHOUT 12" HIGH PANELS CONTINUOUS OVER TWO OR MORE SPANS WITHOUT ENDLAPS. BERRIDGE MANUFACTURING CO. - "CEE-LOCK PANEL" 2. BERRIDGE ALUMINUM CEE-LOCK CLIP - ONE-PIECE 1 " HIGH ASSEMBLY FABRICATED FROM NO. 24 BERRIDGE ALUMINUM CEE-LOCK CLIP - ONE-PIECE 1 " HIGH ASSEMBLY FABRICATED FROM NO. 24 12" HIGH ASSEMBLY FABRICATED FROM NO. 24 MSG (MIN. YIELD STRENGTH 40,000 PSI) STAINLESS STEEL. CEE-LOCK CLIP SPACED 20" ON CENTER AT PANEL SIDE JOINT. 3. FASTENERS (SCREWS) - FASTENERS (SCREWS) - A. FOR ATTACHING "CEE-LOCK CLIP" (ITEM 2) TO LINER (ITEM 6) USE #14-13 DP1 PANCAKE HEAD FOR ATTACHING "CEE-LOCK CLIP" (ITEM 2) TO LINER (ITEM 6) USE #14-13 DP1 PANCAKE HEAD DECK FASTENER THROUGH RIGID BOARD AND CONNECTED TO METAL DECK AT 24" ON CENTER. FASTENER LENGTH TO BE ADJUSTED TO ACCOUNT FOR THICKNESS OF RIGID INSULATION AND LINER PANEL WITH " MINIMUM PENETRATION INTO METAL DECK. 34" MINIMUM PENETRATION INTO METAL DECK. B. FOR CONNECTION OF LINER (ITEM 6) TO PURLIN (ITEM 7) (NOT SHOWN) USE 1/4-14 X 1 " FOR CONNECTION OF LINER (ITEM 6) TO PURLIN (ITEM 7) (NOT SHOWN) USE 1/4-14 X 1 " 14" HWH 36/7 FASTENER PATTERN (FASTENER EVERY LOW FLUTE OF DECK) 4. CLIP BEARING PLATE - 6" X 6" NO. 24 MSG COATED STEEL, USED WITH RIGID INSULATION ONLY. CLIP BEARING PLATE - 6" X 6" NO. 24 MSG COATED STEEL, USED WITH RIGID INSULATION ONLY. 5. BERRIDGE APPROVED PEEL & STICK OR #30 FELT UNDERLAYMENT. BERRIDGE APPROVED PEEL & STICK OR #30 FELT UNDERLAYMENT. 6. INSULATION - MAXIMUM 6" THICK, 2.25 PCF DENSITY 20 PSF COMPRESSIVE STRENGTH RIGID INSULATION - MAXIMUM 6" THICK, 2.25 PCF DENSITY 20 PSF COMPRESSIVE STRENGTH RIGID CLOSED CELL POLYISOCYANURATE CORE FIBERGLASS FACED INSULATION. 7. SUBSTRUCTURE (LINER) - NO. 22 MSG (MIN. YIELD STRENGTH 40,000 PSI) COATED STEEL. SUBSTRUCTURE (LINER) - NO. 22 MSG (MIN. YIELD STRENGTH 40,000 PSI) COATED STEEL. CORRUGATION HEIGHT TO BE MINIMUM 3/4". ENDLAPS TO OCCUR OVER PURLINS WITH PANELS OVERLAPPED MINIMUM 4". 8. PURLINS - NO. 12 MSG (MIN. YIELD STRENGTH 50,000 PSI) COATED STEEL. SPACING TO BE 5'-0" PURLINS - NO. 12 MSG (MIN. YIELD STRENGTH 50,000 PSI) COATED STEEL. SPACING TO BE 5'-0" ON CENTER WHEN ITEM 6 IS CONNECTED TO ITEM 7
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
7
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
8
AutoCAD SHX Text
6
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-90
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL

BERRIDGE

MANUFACTURING

COMPANY

AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
6
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
UL 90 APPROVED ASSEMBLY ALUMINUM CEE-LOCK PANEL WITH STAINLESS STEEL CEE-LOCK CLIPS OVER " PLYWOOD SHEATHING 1532" PLYWOOD SHEATHING PLYWOOD SHEATHING UL CONSTRUCTION NO. 690
AutoCAD SHX Text
1. BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL * - 0.032" COATED BERRIDGE ALUMINUM CEE-LOCK PANEL WITH (OPTIONAL) VINYL WEATHERSEAL * - 0.032" COATED ALUMINUM, 16 " WIDE, 1 " HIGH PANELS CONTINUOUS OVER TWO OR MORE SPANS WITHOUT 12" WIDE, 1 " HIGH PANELS CONTINUOUS OVER TWO OR MORE SPANS WITHOUT 12" HIGH PANELS CONTINUOUS OVER TWO OR MORE SPANS WITHOUT ENDLAPS. BERRIDGE MANUFACTURING CO. - "CEE-LOCK PANEL" 2. BERRIDGE ALUMINUM CEE-LOCK CLIPS - ONE-PIECE 1 " HIGH, X 1 " WIDE X 3 " LONG NO. 24 BERRIDGE ALUMINUM CEE-LOCK CLIPS - ONE-PIECE 1 " HIGH, X 1 " WIDE X 3 " LONG NO. 24 12" HIGH, X 1 " WIDE X 3 " LONG NO. 24 316" WIDE X 3 " LONG NO. 24 12" LONG NO. 24 MSG (MIN. YIELD STRENGTH 40,000 PSI) STAINLESS STEEL. CLIP SPACED 20" ON CENTER AT PANEL SIDE JOINT. 3. FASTENERS (SCREWS) - FASTENERS (SCREWS) - A. FOR ATTACHING "CEE-RIB" (ITEM 2) TO PLYWOOD (ITEM 5) USE #12-11 X 1" PANCAKE HEAD, FOR ATTACHING "CEE-RIB" (ITEM 2) TO PLYWOOD (ITEM 5) USE #12-11 X 1" PANCAKE HEAD, STEEL SCREWS. TWO FASTENERS PER CEE-LOCK CLIP. B. FOR CONNECTING PLYWOOD (ITEM 5) TO PURLIN (ITEM 6) (NOT SHOWN) USE 2 " LONG 8D FOR CONNECTING PLYWOOD (ITEM 5) TO PURLIN (ITEM 6) (NOT SHOWN) USE 2 " LONG 8D 12" LONG 8D HOT GALVANIZED RING SHANK PATIO/DECK NAILS SPACED 6" MAXIMUM AT PLYWOOD TO JOIST CONNECTION AND PLYWOOD ENDS. 4. BERRIDGE APPROVED PEEL & STICK OR #30 FELT UNDERLAYMENT. BERRIDGE APPROVED PEEL & STICK OR #30 FELT UNDERLAYMENT. 5. SUBSTRUCTURE (PLYWOOD) - NOMINAL " THICK, 4-PLY B-C GROUP 1 EXTERIOR PLYWOOD. SUBSTRUCTURE (PLYWOOD) - NOMINAL " THICK, 4-PLY B-C GROUP 1 EXTERIOR PLYWOOD. 1532" THICK, 4-PLY B-C GROUP 1 EXTERIOR PLYWOOD. 6. JOISTS - NOMINAL 2 X 10 WOOD MEMBERS SPACED 2'-0" ON CENTER MAXIMUM. JOISTS - NOMINAL 2 X 10 WOOD MEMBERS SPACED 2'-0" ON CENTER MAXIMUM.
AutoCAD SHX Text
Roofs of Distinction
AutoCAD SHX Text
PAGE\FILE
AutoCAD SHX Text
CLA-91
AutoCAD SHX Text
DATE: 1/21
AutoCAD SHX Text
ALUMINUM CEE-LOCK PANEL