cei-proj_ltd-drawing-prewire_docs-101119.pdf

38
1 38 PW- 11/19/2010 LTD Regency Omaha, NE Prewire documentation DATE: SCALE: DRAWN: SHEET: 7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434 COPYRIGHT Sam G None Drawing-Prewire_docs-LTD-101119.vsd Title pg.1 TITLE: AREA/ROOM: CLIENT: of TABLE OF CONTENTS TITLE PG.1 DETAILED INSTRUCTIONS LEGEND CAT5e Keypad CAT5e Phone CAT5e Network 14/2 Speaker 14/4 Speaker Mon OMC/2C SVRG6 SVRG6 RG6 Quad RGB6C/2CATe RGB3C Mini Component Video HDMI 2 Shielded PR Analog Audio Digital Audio Cresnet Crescat-DC Crescat-Q Romex Conduit (flexible) Conduit (PVC) X-Gang Box Power Inlet Power outlet 1 Prewire documentation Title pg.1 Page 1 004-Bath Page 2 Page 3 Page 4 Page 5 Page 6 005-Bath 009-Stair 006-Entertainment 007-Bar 101-Entry Page 7 102-Gallery 103-Dining 104-Hearth 105-Kitchen 107-Library 108-Hall 109-M Bed 110-Sitting 111-Exercise 114-Laundry 115-M Bath 119-Jeff’s Office 122-2 Car 124-Powder 125-Drop 127-Danielle’s Office 129-3 Car 130-Stair 202-Balcony 203-Hallway Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27

Upload: sam-guarino

Post on 21-Feb-2016

212 views

Category:

Documents


0 download

DESCRIPTION

CEI - Project LTD. The drawing was created for the installation staff to give them all of the information to complete the prewire.

TRANSCRIPT

Page 1: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

1 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

Title pg.1

TITLE:

AREA/ROOM:

CLIENT:

of

TABLE OF CONTENTSTITLE PG.1

DETAILED INSTRUCTIONS

LEGEND

CAT5e Keypad

CAT5e Phone

CAT5e Network

14/2 Speaker

14/4 Speaker

Mon OMC/2C

SVRG6

SVRG6

RG6 Quad

RGB6C/2CATe

RGB3C Mini

Component Video

HDMI

2 Shielded PR

Analog Audio

Digital Audio

Cresnet

Crescat-DC

Crescat-Q

Romex

Conduit (flexible)

Conduit (PVC)

X-Gang Box

Power Inlet

Power outlet

1

Pre

wir

e d

oc

um

en

tati

on

Title pg.1Page 1

004-BathPage 2

Page 3

Page 4

Page 5

Page 6

005-Bath

009-Stair

006-Entertainment

007-Bar

101-EntryPage 7

102-Gallery

103-Dining

104-Hearth

105-Kitchen

107-Library

108-Hall

109-M Bed

110-Sitting

111-Exercise

114-Laundry

115-M Bath

119-Jeff’s Office

122-2 Car

124-Powder

125-Drop

127-Danielle’s Office

129-3 Car

130-Stair

202-Balcony

203-Hallway

Page 8

Page 9

Page 10

Page 11

Page 12

Page 13

Page 14

Page 15

Page 16

Page 17

Page 18

Page 19

Page 20

Page 21

Page 22

Page 23

Page 24

Page 25

Page 26

Page 27

Page 2: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

2 38PW-

11/19/2010

LTD

Regency

Omaha, NEPrewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

Title pg.2

TITLE:

AREA/ROOM:

CLIENT:

of

TABLE OF CONTENTSTITLE PG.2

DETAILED INSTRUCTIONS

LEGEND

CAT5e Keypad

CAT5e Phone

CAT5e Network

14/2 Speaker

14/4 Speaker

Mon OMC/2C

SVRG6

SVRG6

RG6 Quad

RGB6C/2CATe

RGB3C Mini

Component Video

HDMI

2 Shielded PR

Analog Audio

Digital Audio

Cresnet

Crescat-DC

Crescat-Q

Romex

Conduit (flexible)

Conduit (PVC)

X-Gang Box

Power Inlet

Power outlet

1

Pre

wir

e d

oc

um

en

tati

on

206-PlayroomPage 1

208-BedroomPage 2

Page 3

Page 4

Page 5

Page 6

209-Bedroom

Structured Wiring

210-Bath

211-Bath

WallplatesPage 7

Lighting

Climate

Shades

Page 8

Page 9

Page 10

Page 3: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

1

3 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

004-Bath

TITLE:

AREA/ROOM:

CLIENT:

of

004-Bath

LIGHTING KEYPAD

Location: South wall entry

Height: Standard light switch

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

004-BATH

DETAILED INSTRUCTIONS

CRESNET

1LIGHTING KEYPAD

Location: Water closet – west wall entry

Height: Standard light switch

CRESNET

Page 4: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

1

4 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

005-Bath

TITLE:

AREA/ROOM:

CLIENT:

of

005-Bath

LIGHTING KEYPAD

Location: South wall entry

Height: Standard light switch

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

005-BATH

DETAILED INSTRUCTIONS

CRESNET

Page 5: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

2

2

2

FRONT LEFT

Location: West wall

Height: In-wall

006-Entertainment

5 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

006-Entertainment

TITLE:

AREA/ROOM:

CLIENT:

of

FRONT CENTER

Location: West wall

Height: In-wall

FRONT RIGHT

Location: West wall

Height: In-wall

REAR LEFT/RIGHT

Location: TBD

Height: In-ceiling

S14/2

S14/2

S14/2

SUBWOOFER

Location: West wall

Height: In-cabinet1

22/2pr

SUBWOOFER

Location: West wall

Height: In-wall

S14/4

006-

ENTERTAINMENT

DETAILED INSTRUCTIONS

LEGEND

CAT5e Keypad

CAT5e Phone

CAT5e Network

14/2 Speaker

14/4 Speaker

Mon OMC/2C

SVRG6

SVRG6

RG6 Quad

RGB6C/2CATe

RGB3C Mini

Component Video

HDMI

2 Shielded PR

Analog Audio

Digital Audio

Cresnet

Crescat-DC

Crescat-Q

Romex

Conduit (flexible)

Conduit (PVC)

X-Gang Box

Power Inlet

Power outlet

1

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

S14/4

CRESCAT-DC

DM-CBL-NP

TV

Location: West wall

Height: TBD

TV

Location: West wall

Height: TBD

AQ HDMI-_ _._MTV

Location: West wall

Height: TBD

Page 6: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

6 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

007-Bar

TITLE:

AREA/ROOM:

CLIENT:

of

007-Bar

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

007-BAR

DETAILED INSTRUCTIONS

2

2

2

LEFT/RIGHT

Location: TBD

Height: In-ceiling

S14/4

CRESCAT-DC

DM-CBL-NP

TV

Location: West wall

Height: TBD

TV

Location: West wall

Height: TBD

AQ HDMI-_ _._MTV

Location: West wall

Height: TBD

1LIGHTING KEYPAD

Location: TBD

Height: Standard light switch

CRESNET

Page 7: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

7 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

009-Stair

TITLE:

AREA/ROOM:

CLIENT:

of

009-Stair

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

009-STAIR

DETAILED INSTRUCTIONS

1LIGHTING KEYPAD

Location: East wall

Height: Standard light switch

CRESNET

1THERMOSTAT/TEMP. SENSOR

Location: TBD

Height: Standard thermostat

CRESNET

Page 8: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

1

8 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

101-Entry

TITLE:

AREA/ROOM:

CLIENT:

of

101-Entry

LIGHTING KEYPAD

Location: East wall entry

Height: Standard light switch

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

101-ENTRY

DETAILED INSTRUCTIONS

CRESNET

Page 9: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

1

9 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

102-Gallery

TITLE:

AREA/ROOM:

CLIENT:

of

102-Gallery

LIGHTING KEYPAD

Location: TBD

Height: Standard light switch

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

102-GALLERY

DETAILED INSTRUCTIONS

CRESNET

1THERMOSTAT/TEMP. SENSOR

Location: TBD

Height: Standard thermostat

CRESNET

Page 10: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

1

10 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

103-Dining

TITLE:

AREA/ROOM:

CLIENT:

of

103-Dining

LIGHTING KEYPAD

Location: East entry

Height: Standard light switch

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

103-DINING

DETAILED INSTRUCTIONS

CRESNET

1THERMOSTAT/TEMP. SENSOR

Location: TBD

Height: Standard thermostat

CRESNET

Page 11: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

104-HEARTH

DETAILED INSTRUCTIONS

LEGEND

CAT5e Keypad

CAT5e Phone

CAT5e Network

14/2 Speaker

14/4 Speaker

Mon OMC/2C

SVRG6

SVRG6

RG6 Quad

RGB6C/2CATe

RGB3C Mini

Component Video

HDMI

2 Shielded PR

Analog Audio

Digital Audio

Cresnet

Crescat-DC

Crescat-Q

Romex

Conduit (flexible)

Conduit (PVC)

X-Gang Box

Power Inlet

Power outlet

1

2

2

2

FRONT LEFT

Location: North wall

Height: In-wall

104-Hearth

11 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

104-Hearth

TITLE:

AREA/ROOM:

CLIENT:

of

FRONT CENTER

Location: North wall

Height: In-wall

FRONT RIGHT

Location: North wall

Height: In-wall

REAR LEFT/RIGHT

Location: TBD

Height: In-ceiling

S14/2

S14/2

S14/2

SUBWOOFER

Location: West wall

Height: In-wall

S14/4

104-HEARTH

DETAILED INSTRUCTIONS

LEGEND

CAT5e Keypad

CAT5e Phone

CAT5e Network

14/2 Speaker

14/4 Speaker

Mon OMC/2C

SVRG6

SVRG6

RG6 Quad

RGB6C/2CATe

RGB3C Mini

Component Video

HDMI

2 Shielded PR

Analog Audio

Digital Audio

Cresnet

Crescat-DC

Crescat-Q

Romex

Conduit (flexible)

Conduit (PVC)

X-Gang Box

Power Inlet

Power outlet

1

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

S14/4

CRESCAT-DC

DM-CBL-NP

TV

Location: North wall

Height: TBD

TV

Location: North wall

Height: TBD

AQ HDMI-_ _._MTV

Location: North wall

Height: TBD

1LIGHTING KEYPAD

Location: West wall sliding door

Height: Standard light switch

CRESNET

Page 12: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

1

12 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

105-Kitchen

TITLE:

AREA/ROOM:

CLIENT:

of

105-Kitchen

AV KEYPAD

Location: West wall sliding door

Height: Standard keypad

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

105-KITCHEN

DETAILED INSTRUCTIONS

CRESNET

2

2

2

LEFT/RIGHT

Location: TBD

Height: In-ceiling

S14/4

CRESCAT-DC

DM-CBL-NP

TV

Location: East wall

Height: TBD

TV

Location: East wall

Height: TBD

AQ HDMI-_ _._MTV

Location: East wall

Height: TBD

1LIGHTING KEYPAD

Location: West wall sliding door

Height: Standard light switch

CRESNET

1LIGHTING KEYPAD

Location: East wall

Height: Standard light switch

CRESNET

1THERMOSTAT/TEMP. SENSOR

Location: East wall

Height: Standard thermostat

CRESNET

Page 13: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

1

13 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

107-Library

TITLE:

AREA/ROOM:

CLIENT:

of

107-Library

AV KEYPAD

Location: TBD

Height: Standard keypad

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

107-LIBRARY

DETAILED INSTRUCTIONS

CRESNET

LEFT/RIGHT

Location: TBD

Height: In-ceiling

S14/4

1LIGHTING KEYPAD

Location: TBD

Height: Standard light switch

CRESNET

Page 14: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

14 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

108-Hall

TITLE:

AREA/ROOM:

CLIENT:

of

108-Hall

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

108-HALL

DETAILED INSTRUCTIONS

1LIGHTING KEYPAD

Location: TBD

Height: Standard light switch

CRESNET

Page 15: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

15 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

109-M Bed

TITLE:

AREA/ROOM:

CLIENT:

of

109-M Bed

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

109-M BED

DETAILED INSTRUCTIONS

1LIGHTING KEYPAD

Location: East wall – his bedside

Height: Standard light switch

CRESNET

1LIGHTING KEYPAD

Location: East wall – her bedside

Height: Standard light switch

CRESNET

1THERMOSTAT/TEMP. SENSOR

Location: North wall

Height: Standard thermostat

CRESNET

Page 16: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

16 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

110-Sitting

TITLE:

AREA/ROOM:

CLIENT:

of

110-Sitting

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

110-SITTING

DETAILED INSTRUCTIONS

2

2

2

LEFT/RIGHT

Location: TBD

Height: In-wall

SUBWOOFER

Location: TBD

Height: In-cabinet1

22/2pr

SUBWOOFER

Location: TBD

Height: In-wall

S14/4

S14/4

CRESCAT-DC

DM-CBL-NP

TV

Location: West wall

Height: TBD

TV

Location: West wall

Height: TBD

AQ HDMI-_ _._MTV

Location: West wall

Height: TBD

Page 17: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

17 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

111-Exercise

TITLE:

AREA/ROOM:

CLIENT:

of

111-Exercise

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

111-EXERCISE

DETAILED INSTRUCTIONS

2

2

2

LEFT/RIGHT

Location: TBD

Height: In-ceiling

S14/4

CRESCAT-DC

DM-CBL-NP

TV

Location: East wall

Height: TBD

TV

Location: East wall

Height: TBD

AQ HDMI-_ _._MTV

Location: East wall

Height: TBD

1LIGHTING KEYPAD

Location: East wall door

Height: Standard light switch

CRESNET

1THERMOSTAT/TEMP. SENSOR

Location: East wall door

Height: Standard thermostat

CRESNET

Page 18: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

18 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

114-Laundry

TITLE:

AREA/ROOM:

CLIENT:

of

114-Laundry

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

114-LAUNDRY

DETAILED INSTRUCTIONS

2

2

2

CRESCAT-DC

DM-CBL-NP

TV

Location: TBD

Height: TBD

TV

Location: TBD

Height: TBD

AQ HDMI-_ _._MTV

Location: TBD

Height: TBD

1LIGHTING KEYPAD

Location: South wall entry

Height: Standard light switch

CRESNET

1THERMOSTAT/TEMP. SENSOR

Location: South wall entry

Height: Standard thermostat

CRESNET

Page 19: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

19 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

115-M Bath

TITLE:

AREA/ROOM:

CLIENT:

of

115-M Bath

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

115-M BATH

DETAILED INSTRUCTIONS

2

2

2

LEFT/RIGHT

Location: TBD

Height: In-ceiling

S14/4

CRESCAT-DC

DM-CBL-NP

TV

Location: East wall

Height: TBD

TV

Location: East wall

Height: TBD

AQ HDMI-_ _._MTV

Location: East wall

Height: TBD

1LIGHTING KEYPAD

Location: East wall – her vanity

Height: Standard light switch

CRESNET

STEREO

Location: Shower

Height: In-ceiling

S14/4

1LIGHTING KEYPAD

Location: East wall – his vanity

Height: Standard light switch

CRESNET

Page 20: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

20 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

119-Jeff's Office

TITLE:

AREA/ROOM:

CLIENT:

of

119-Jeff's Office

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

119-JEFF'S OFFICE

DETAILED INSTRUCTIONS

2

2

2

LEFT/RIGHT

Location: TBD

Height: In-ceiling

S14/4

CRESCAT-DC

DM-CBL-NP

TV

Location: South wall

Height: TBD

TV

Location: South wall

Height: TBD

AQ HDMI-_ _._MTV

Location: South wall

Height: TBD

1LIGHTING KEYPAD

Location: East wall entry

Height: Standard light switch

CRESNET

1THERMOSTAT/TEMP. SENSOR

Location: East wall entry

Height: Standard thermostat

CRESNET

Page 21: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

21 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

122-2 Car

TITLE:

AREA/ROOM:

CLIENT:

of

122-2 Car

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

122-2 CAR

DETAILED INSTRUCTIONS

1LIGHTING KEYPAD

Location: East wall outdoor entry

Height: Standard light switch

CRESNET

1THERMOSTAT/TEMP. SENSOR

Location: South wall entry

Height: Standard thermostat

CRESNET

22/2prDOOR SENSOR

Location: East wall – between door 1/2

Height: Top of door

Page 22: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

1

22 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

124-Powder

TITLE:

AREA/ROOM:

CLIENT:

of

124-Powder

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

124-POWDER

DETAILED INSTRUCTIONS

CRESNETLIGHTING KEYPAD

Location: Entry

Height: Standard light switch

Page 23: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

23 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

125-Drop

TITLE:

AREA/ROOM:

CLIENT:

of

125-Drop

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

125-DROP

DETAILED INSTRUCTIONS

1LIGHTING KEYPAD

Location: North wall entry

Height: Standard light switch

CRESNET

1LIGHTING KEYPAD

Location: West wall pocket door

Height: Standard light switch

CRESNET

1LIGHTING KEYPAD

Location: East wall entry

Height: Standard light switch

CRESNET

Page 24: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

24 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

127-Danielle's Office

TITLE:

AREA/ROOM:

CLIENT:

of

127-Danielle's Office

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

127-DANIELLE'S

OFFICE

DETAILED INSTRUCTIONS

2

2

2

LEFT/RIGHT

Location: TBD

Height: In-ceiling

S14/4

CRESCAT-DC

DM-CBL-NP

TV

Location: Northeast wall

Height: TBD

TV

Location: Northeast wall

Height: TBD

AQ HDMI-_ _._MTV

Location: Northeast wall

Height: TBD

1LIGHTING KEYPAD

Location: North wall entry

Height: Standard light switch

CRESNET

Page 25: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

25 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

129-3 Car

TITLE:

AREA/ROOM:

CLIENT:

of

129-3 Car

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

129-3 CAR

DETAILED INSTRUCTIONS

1LIGHTING KEYPAD

Location: North wall outdoor entry

Height: Standard light switch

CRESNET

1THERMOSTAT/TEMP. SENSOR

Location: East wall entry

Height: Standard thermostat

CRESNET

22/2prDOOR SENSOR

Location: North wall – between door 1/2

Height: Top of door

22/2prDOOR SENSOR

Location: North wall – between door 2/3

Height: Top of door

Page 26: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

26 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

130-Stair

TITLE:

AREA/ROOM:

CLIENT:

of

130-Stair

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

130-STAIR

DETAILED INSTRUCTIONS

1LIGHTING KEYPAD

Location: West wall

Height: Standard light switch

CRESNET

1LIGHTING KEYPAD

Location: East wall

Height: Standard light switch

CRESNET

Page 27: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

27 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

202-Balcony

TITLE:

AREA/ROOM:

CLIENT:

of

202-Balcony

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

202-BALCONY

DETAILED INSTRUCTIONS

1LIGHTING KEYPAD

Location: East wall

Height: Standard light switch

CRESNET

Page 28: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

28 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

203-Hallway

TITLE:

AREA/ROOM:

CLIENT:

of

203-Hallway

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

203-HALLWAY

DETAILED INSTRUCTIONS

1LIGHTING KEYPAD

Location: South wall entry

Height: Standard light switch

CRESNET

Page 29: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

206-PLAYROOM

DETAILED INSTRUCTIONS

LEGEND

CAT5e Keypad

CAT5e Phone

CAT5e Network

14/2 Speaker

14/4 Speaker

Mon OMC/2C

SVRG6

SVRG6

RG6 Quad

RGB6C/2CATe

RGB3C Mini

Component Video

HDMI

2 Shielded PR

Analog Audio

Digital Audio

Cresnet

Crescat-DC

Crescat-Q

Romex

Conduit (flexible)

Conduit (PVC)

X-Gang Box

Power Inlet

Power outlet

1

2

2

FRONT LEFT

Location: TBD

Height: In-ceiling

206-Playroom

29 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

206-Playroom

TITLE:

AREA/ROOM:

CLIENT:

of

FRONT CENTER

Location: TBD

Height: In-ceiling

FRONT RIGHT

Location: TBD

Height: In-ceiling

REAR LEFT/RIGHT

Location: TBDl

Height: In-ceiling

S14/2

S14/2

S14/2

SUBWOOFER

Location: TBD

Height: In-cabinet1

22/2pr

SUBWOOFER

Location: TBD

Height: In-wall

S14/4

206-PLAYROOM

DETAILED INSTRUCTIONS

LEGEND

CAT5e Keypad

CAT5e Phone

CAT5e Network

14/2 Speaker

14/4 Speaker

Mon OMC/2C

SVRG6

SVRG6

RG6 Quad

RGB6C/2CATe

RGB3C Mini

Component Video

HDMI

2 Shielded PR

Analog Audio

Digital Audio

Cresnet

Crescat-DC

Crescat-Q

Romex

Conduit (flexible)

Conduit (PVC)

X-Gang Box

Power Inlet

Power outlet

1

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

S14/4

DM-CBL-NPTV

Location: West wall

Height: TBD

AQ HDMI-_ _._MTV

Location: West wall

Height: TBD

1LIGHTING KEYPAD

Location: West wall entry

Height: Standard light switch

CRESNET

1THERMOSTAT/TEMP. SENSOR

Location: West wall entry

Height: Standard thermostat

CRESNET

2CRESCAT-DC

TV

Location: West wall

Height: TBD

Page 30: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

30 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

208-Bedroom

TITLE:

AREA/ROOM:

CLIENT:

of

208-Bedroom

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

208-BEDROOM

DETAILED INSTRUCTIONS

1LIGHTING KEYPAD

Location: North wall entry

Height: Standard light switch

CRESNET

Page 31: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

31 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

209-Bedroom

TITLE:

AREA/ROOM:

CLIENT:

of

209-Bedroom

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

209-BEDROOM

DETAILED INSTRUCTIONS

1LIGHTING KEYPAD

Location: North wall entry

Height: Standard light switch

CRESNET

Page 32: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

32 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

210-Bath

TITLE:

AREA/ROOM:

CLIENT:

of

210-Bath

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

210-BATH

DETAILED INSTRUCTIONS

1LIGHTING KEYPAD

Location: West wall entry

Height: Standard light switch

CRESNET

Page 33: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

33 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

211-Bath

TITLE:

AREA/ROOM:

CLIENT:

of

211-Bath

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

211-BATH

DETAILED INSTRUCTIONS

1LIGHTING KEYPAD

Location: East wall entry

Height: Standard light switch

CRESNET

Page 34: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

34 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

Structured Wiring

TITLE:

AREA/ROOM:

CLIENT:

of

KITCHEN - 001

PHONE

Location: Right side of island

Height: TBD

KRISTI’S OFFICE - 003

SITTING ROOM - 002

PHONE/NETWORK

Location: Shared kitchen wall

Height: 24" ABFF

1PHONE/NETWORK

Location: Shared garage wall

Height: 24" ABFF

CATV

Location: TV niche

Height: TBD

2

1PHONE

Location: TBD

Height: In-floor

CAT5e (gray)

DM-CBL-NP

CRESCAT-DC CATV

Location: TV niche

Height: TBD

1CAT5e (blue)

CAT5e (gray)

CAT5e (blue)

CAT5e (gray)

2

1CAT5e (gray)

DM-CBL-NP

CRESCAT-DC

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

STRUCTURED

WIRING

DETAILED INSTRUCTIONS

LEGEND

CAT5e Keypad

CAT5e Phone

CAT5e Network

14/2 Speaker

14/4 Speaker

Mon OMC/2C

SVRG6

SVRG6

RG6 Quad

RGB6C/2CATe

RGB3C Mini

Component Video

HDMI

2 Shielded PR

Analog Audio

Digital Audio

Cresnet

Crescat-DC

Crescat-Q

Romex

Conduit (flexible)

Conduit (PVC)

X-Gang Box

Power Inlet

Power outlet

1

Page 35: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

35 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

Wallplates

TITLE:

AREA/ROOM:

CLIENT:

of

PH

ON

E

NE

TW

OR

K

PH

ON

E/N

ET

WO

RK

AREA: KITCHEN

LOCATION: ISLAND

4 P

OR

T AREA: KITCHEN

LOCATION: IN-

CABINET

AREA: SITTING ROOM

LOCATION: IN-FLOOR

AREA: KRISTI’S

OFFICE

LOCATION: UNDER

DESK 24" ABFF

AREA: KRISTI’S

OFFICE

LOCATION: UNDER

DESK 24" ABFF

AREA: KRISTI’S

OFFICE

LOCATION: UNDER

DESK 24" ABFF

AREA: SITTING ROOM

LOCATION: IN-

CABINET

Page 36: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

36 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

Lighting

TITLE:

AREA/ROOM:

CLIENT:

of

STAIR - 006

KITCHEN - 001

LIVING ROOM - 010

DINING ROOM - 007

KRISTI’S OFFICE - 003

SITTING ROOM - 002

KEYPAD

Location: East wall

Height: Standard above counter1

CRESNET

KEYPAD

Location: Left of deck doorway

Height: Standard lighting keypad1

CRESNET

KEYPAD

Location: Left of office entry

Height: Standard lighting keypad1

CRESNET

KEYPAD

Location: Right of deck doorway

Height: Standard lighting keypad1

CRESNET

KEYPAD

Location: Left of MBR doorway

Height: Standard lighting keypad1

CRESNET

ENTRY - 012

MAIN FLOOR HALLWAY - 011

GARAGE - 007

KEYPAD

Location: Right of garage doorway

Height: Standard lighting keypad1

CRESNET

KEYPAD

Location: Just inside hallway wall

Height: Standard lighting keypad1

CRESNET

KEYPAD

Location: Left of garage doorway

Height: Standard lighting keypad1

CRESNET

KEYPAD

Location: TBD

Height: Standard lighting keypad1

CRESNET

KEYPAD

Location: Right of entry doorway

Height: Standard lighting keypad1

CRESNET

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

LIGHTING

DETAILED INSTRUCTIONS

LEGEND

CAT5e Keypad

CAT5e Phone

CAT5e Network

14/2 Speaker

14/4 Speaker

Mon OMC/2C

SVRG6

SVRG6

RG6 Quad

RGB6C/2CATe

RGB3C Mini

Component Video

HDMI

2 Shielded PR

Analog Audio

Digital Audio

Cresnet

Crescat-DC

Crescat-Q

Romex

Conduit (flexible)

Conduit (PVC)

X-Gang Box

Power Inlet

Power outlet

1

Page 37: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

MAIN FLOOR HALLWAY

2ND

FLOOR HALLWAY

37 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

Climate

TITLE:

AREA/ROOM:

CLIENT:

of

THERMOSTAT

Location: Same as existing t-stat

Height: Standard audio keypad

OUTDOOR

TEMP SENSOR

Location: Basement level TBD

Height: Approx. 5ft off of ground

CRESNET

1THERMOSTAT

Location: Same as existing t-stat

Height: Standard audio keypad

CRESNET

ROUGH-IN STUBOUT

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack from

floor at HR rack location to

provide ample room for

installation, cable mgmt and

servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

CLIMATE

DETAILED INSTRUCTIONS

LEGEND

CAT5e Keypad

CAT5e Phone

CAT5e Network

14/2 Speaker

14/4 Speaker

Mon OMC/2C

SVRG6

SVRG6

RG6 Quad

RGB6C/2CATe

RGB3C Mini

Component Video

HDMI

2 Shielded PR

Analog Audio

Digital Audio

Cresnet

Crescat-DC

Crescat-Q

Romex

Conduit (flexible)

Conduit (PVC)

X-Gang Box

Power Inlet

Power outlet

1

1CRESNET

Page 38: CEI-Proj_LTD-Drawing-prewire_docs-101119.pdf

38 38PW-

11/19/2010

LTD

Regency

Omaha, NE Prewire documentation DATE:

SCALE:

DRAWN:

SHEET:

7511 Pacific Street | Omaha | Nebraska 68114 | 402-397-4434

COPYRIGHT

Sam G

None

Drawing-Prewire_docs-LTD-101119.vsd

Shades

TITLE:

AREA/ROOM:

CLIENT:

of

A 1-gang box should be used

for each of the keypad

locations unless specified

otherwise.

Leave 5-6 feet of slack at

room locations to provide

ample room for installation

and servicing.

Leave 8-10 feet of slack at HR

rack location here to provide

ample room for installation,

cable mgmt and servicing.

All wires must be clearly

labeled w/ labels or white tape

w/ black marker or by some

other means.

We need (1) dedicated

isolated ground outlet here.

This will be connected to the

housewide audio equipment.

SHADES

DETAILED INSTRUCTIONS

LEGEND

CAT5e Keypad

CAT5e Phone

CAT5e Network

14/2 Speaker

14/4 Speaker

Mon OMC/2C

SVRG6

SVRG6

RG6 Quad

RGB6C/2CATe

RGB3C Mini

Component Video

HDMI

2 Shielded PR

Analog Audio

Digital Audio

Cresnet

Crescat-DC

Crescat-Q

Romex

Conduit (flexible)

Conduit (PVC)

X-Gang Box

Power Inlet

Power outlet

1

OUTDOOR

PHOTOCELL SENSOR

Location: Not in direct sunlight

Height: Under eave

CRESNET

ROUGH-IN STUBOUT