Order of Presentation
1.) Introduction of existing device2.) Problems with the existing device3.) Customer's Needs4.) Break-up device into sub-assemblies5.) In depth details of sub-assemblies6.) Different combinations of different sub-
assemblies7.) Design concept decided on
![Page 3: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/3.jpg)
Introduction of Existing Device
![Page 4: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/4.jpg)
Step 1.
![Page 5: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/5.jpg)
Bushing and Magnet holding Fixture
![Page 6: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/6.jpg)
Dial Indicators used to measure the magnet and bushing position
![Page 7: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/7.jpg)
A closer look at the positioning process
![Page 8: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/8.jpg)
Magnet mapping sensors and pusher assembly
![Page 9: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/9.jpg)
Hall Effect Sensors
![Page 10: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/10.jpg)
Physical device used to push the magnet
![Page 11: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/11.jpg)
Process of Mapping and Pushing the Magnet
1. Aligning linear stages 2. Determining the position of the bushing and magnet using
the dial indicators3. Rotating the entire assembly and mapping the magnetic
field4. Calculating the max and min of the magnetic field and
determine the location of the maximum value5. Rotating the magnet and bushing assembly to the
maximum location 6. Move assembly to the pushing device where it moves the
magnet7. This process is repeated until the magnetic field and
bushing are concentric to 20 microns
![Page 12: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/12.jpg)
Issues with this process
• Manual process involved• Physically measuring the position of parts• Human error• Indicator being destroyed • Holding magnet and bushing• Pushing the magnet• Moving parts
![Page 13: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/13.jpg)
Customer Need’s
![Page 14: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/14.jpg)
![Page 15: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/15.jpg)
Sub Assemblies
• Assemblies Orientation• Physically holding parts• Measuring parts• Mapping magnetic field• Centering magnet• Adhering magnet to bushing• Confirming and validating
![Page 16: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/16.jpg)
Assembly Orientation
Vertical or horizontal
![Page 17: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/17.jpg)
Holding Fixture: Pugh Chart
![Page 18: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/18.jpg)
Holding Component
• Post • Chuck• Combination of both
![Page 19: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/19.jpg)
Measuring and mapping parts
• Hall effect sensors will measure the magnetic fields, choices to be decides from are: – A single sensor which moves– An array of sensors
• The position of the bushings:– Will not involve a human operator – Will not touch the components
![Page 20: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/20.jpg)
Centering Magnets
• Option 1– Having the entire bushing/magnet assembly move
towards a physical device like the existing device• Option 2– Move a physical device towards the bushing/magnet
assembly• Option 3– A bushing which is stationary and a bushing that moves
• Option 4– A magnet which is stationary and a bushing that moves
![Page 21: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/21.jpg)
Adhering
• Automated gluing • Heat activated composites• UV activated• Ultra sonic• Applying a pressure to the centered assembly
then gluingThis sub assembly will be determined once the
holding and centering of magnet are chosen
![Page 22: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/22.jpg)
Design concept decided on
• The magnet/bushing assembly will be vertical• An array of Hall Effect sensors will be implemented• Option 4: having the magnet stationary while
moving the bushing
![Page 23: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/23.jpg)
Why this configuration
• Vertical eliminates gravity• No gravity eliminates forces • An array eliminates a moving element• The magnetic field be the reference point• Magnet centers change from magnet to
magnet, bushings do not
![Page 24: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/24.jpg)
Different configurations
• Magnet above bushing• Magnet below bushing• Bushing is placed on magnet, manually
![Page 25: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/25.jpg)
Magnet held in place on top
![Page 26: Centering Magnet Device P08028 A.Burger J. Lu D. Falcinelli M. Brown](https://reader035.vdocuments.net/reader035/viewer/2022062421/56649d6d5503460f94a4d10b/html5/thumbnails/26.jpg)
Magnet held in place on bottom