central park block 11 - major projects

1
FAC01 FAC03 FAC04 FAC05 FAC06 FAC07 FAC08 FAC09 FAC10 FAC11 Anodised aluminium Curtain Wall System with integrated operable windows with aluminium clip-on custom profiled extrusions Anodised aluminium Window Wall System with integrated operable windows and door systems (allow for 50/50 split between sliding and bi-fold functionality). Fenestration to facade system being anodised aluminium operable bi-fold perforated sunshade screens (allow for floor to floor coverage) FAC02 Anodised aluminium Window Wall System with integrated operable window and door systems (allow for 50/50 split between sliding and bi-fold functionality). Terracotta cladding (allow for minimum 1200 wide module) Anodised aluminium sliding sunshade screen batten panels with battens at typically 100mm CC, 50mm SHS profile to framing and battens. Anodised aluminium Curtain Wall System with integrated operable windows and door system s (allow for 50/50 split between sliding and bi-fold functionality) with aluminium clip-on custom profiled extrusions Anodised aluminium Curtain Wall System with integrated operable windows (allow for panel lift type e.g. "Renlita") and door systems (allow for full height pivot functionality). Aluminium clip-on custom profiled extrusions to facade. Full height aluminium clip-on custom profiled extrusions Brick Type 1 colour (earthy rust). Bowral pressed or similar. Final selection as per materials board. Rendered Masonry with integrated anodised aluminium window systems Balustrade, Frameless glazing with powder coated 8mm plate aluminium portal framing. Glazing is not captured all round BYR1 Stainless steel Bicycle Rail DG1 Decomposed Granite Gravel DG2 Decorative Gravel HR2 Stainless steel Handrail P1 Paving Type 1 City of Sydney Precast Paving P2 Paving Type 2 Precast Concrete Paving with Granite stone inlay P3 Paving Type 3 Granite Sets (to parking bays) P4 Paving Type 4 Exposed Aggregate Concrete path P5 Paving Type 5 Precast paving to traffic areas P6 Paving Type 6 Brick Paving PIT Proposed Service Pits RW1 Brick base with a Timber capping Retaining wall RW2 Brick base with a Precast concrete capping Retaining wall RW3 Insitu concrete Retaining wall ST1 Corten Steel Edging TD1 Timber Bench Seats TD2 Timber Composite vertical batten screen TD3 Timber Decking LP1 Lighting strip BO1 Stainless steel Bollard S STUDIO 1B 1 BED 1BM 1 BED + MEDIA NOOK 1BS 1 BED + STUDY 2B 2 BED 2BM 2 BED + MEDIA NOOK 2BS 2 BED + STUDY 2BK 2 BED DUAL KEY 2BT 2 BED 2 STOREY TERRACE 3B 3 BED 3BM 3 BED + MEDIA NOOK 3BS 3 BED + STUDY 4B 4 BED RETAIL + NON-RESIDENTIAL CHILDCARE EXTERNAL AREA COURTYARD/BALCONY/WINTER-GARDEN 2 HOURS OF SUNLIGHT ACCESS NATURAL VENTILATION (NV) WIDE FRONTAGE NATURALLY VENTILLATED ASSISTED VENTILATION SOUTH FACING APARTMENT ADAPTABLE APARTMENT LOBBY DUCTED VENTILATION APARTMENT ASSIST VENT DUCT ASSISTED VENTILATION GOOD VENTILATION NATURAL VENTILATION LOBBY CROSS VENTILATION RW4 Heritage Interpretation wall FAC12 Profiled anodised aluminium vertical batten using "clip-on" fixing as noted in elevation (to stairs) Fixed horizontal glass louvres FAC13 BS01 Balustrade Type 01 CCTV Camera Frasers Broadway Suite 11, Lumiere Commercial, Level 12, 101 Bathurst Street, Sydney, NSW, 2000, Australia Frasers Broadway Suite 11, Lumiere Commercial, Level 12, 101 Bathurst Street, Sydney, NSW, 2000, Australia NATURAL VENTILATION DW DW E-1308 1B W & D FS-04-13 Fire Stair F F F W & D W & D W & D W & D W & D W & D W & D W & D F F F F F 01 SSDA-11-302 01 SSDA-11-302 01 SSDA-11-302 01 SSDA-11-302 FH 01 SSDA-11-301 01 SSDA-11-301 L-01 LIFT L-02 LIFT E-1301 3B E-1303 2B E-1302 2BM E-1307 1BS L-01 LIFT L-02 LIFT E-1300 Corridor E-1300 Lobby Bin Room SP SP CHW HHW FH RKE FH GR VENT CKE RKE LRA FE BPV M LRA RKE RKE LSA FS HYD COMMS HYD ELEC HYD HYD FS HYD FE P-1301 Hydraulic Plant Room 01 SSDA-11-401 02 SSDA-11-401 02 SSDA-11-402 01 SSDA-11-402 F DW DW DW DW DW BLOCK 11 LOT BOUNDARY E-1304 1BM X1 A A B B C C D D E E F F G G H H I I 1 1 4 4 20 20 21 21 22 22 Y1 Y2 Y3 XB X1 XC XD 24 24 31 O O P P Q Q S S T T U U V V ZF ZE ZD ZC ZB ZA 30 25 25 2 2 3 3 R R SC SD SE EA EA FA FA GA GA 32 J J K K L L M M DA DA UA UA 23 23 33 FA FA DP DP DP DP DP DP DP DP DP DP E-1305 2BM E-1306 1BM E-1309 1B FS-06-13 Fire Stair 0 2.5 5 10m LEGEND C FRANCIS-JONES MOREHEN THORP PTY LTD 2017 ABN 28 101 197 219 GENERAL NOTES ALL DIMENSIONS AND EXISITNG CONDITIONS SHALL BE CHECKED AND VERIFIED BY THE CONTRACTOR BEFORE PROCEEDING WITH THE WORK ALL LEVELS RELATIVE TO 'AUSTRALIAN HEIGHT DATUM' DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY SHEET NO. DATE SCALE APPROVED DRAWN PROJECT CODE TITLE PROJECT REVISION Central Park Block 11 O'Connor Street, Chippendale Sydney Frasers Broadway PLANS Level 13 Issued for Approval FB11 24/10/2014 1:250 @ A1 SSDA-11-210 05 FJMT SB SYDNEY Level 5, 70 King Street Sydney NSW 2000 Australia T +61 2 9251 7077 F +61 2 9251 7072 E [email protected] W www.fjmt.com.au NOMINATED ARCHITECT: RICHARD FRANCIS-JONES (REG NO 5301) ARCHITECT CLIENT REV. DATE DESCRIPTION BY 01 1:250 PLAN Level 13 WHEN PRINTED AT 50% ON A3 THE SCALE IS 1:500 02 03/07/2015 REFER REVISION CLOUDS FJMT 01 24/10/2014 ISSUED FOR SSDA APPROVAL FJMT 03 21/06/2016 REVISED SSDA FJMT 04 01/12/2016 ISSUED FOR S96 APPROVAL FJMT 05 08/09/2017 ISSUED FOR S96 APPROVAL FJMT

Upload: others

Post on 14-Nov-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Central Park Block 11 - Major Projects

FAC01

FAC03

FAC04FAC05

FAC06

FAC07

FAC08FAC09

FAC10

FAC11

Anodised aluminium Curtain Wall System with integrated operablewindows with aluminium clip-on custom profiled extrusions

Anodised aluminium Window Wall System with integrated operablewindows and door systems (allow for 50/50 split between sliding andbi-fold functionality). Fenestration to facade system being anodisedaluminium operable bi-fold perforated sunshade screens (allow forfloor to floor coverage)

FAC02

Anodised aluminium Window Wall System with integrated operablewindow and door systems (allow for 50/50 split between sliding andbi-fold functionality).

Terracotta cladding (allow for minimum 1200 wide module)

Anodised aluminium sliding sunshade screen batten panels withbattens at typically 100mm CC, 50mm SHS profile to framing andbattens.

Anodised aluminium Curtain Wall System with integrated operablewindows and door system s (allow for 50/50 split between slidingand bi-fold functionality) with aluminium clip-on custom profiledextrusions

Anodised aluminium Curtain Wall System with integrated operablewindows (allow for panel lift type e.g. "Renlita") and door systems(allow for full height pivot functionality). Aluminium clip-on customprofiled extrusions to facade.

Full height aluminium clip-on custom profiled extrusionsBrick Type 1 colour (earthy rust). Bowral pressed or similar. Finalselection as per materials board.Rendered Masonry with integrated anodised aluminium windowsystemsBalustrade, Frameless glazing with powder coated 8mm platealuminium portal framing. Glazing is not captured all round

BYR1 Stainless steel Bicycle Rail

DG1 Decomposed Granite Gravel

DG2 Decorative Gravel

HR2 Stainless steel Handrail

P1 Paving Type 1City of Sydney Precast Paving

P2 Paving Type 2Precast Concrete Paving with Granite stone inlay

P3 Paving Type 3Granite Sets (to parking bays)

P4 Paving Type 4Exposed Aggregate Concrete path

P5 Paving Type 5Precast paving to traffic areas

P6 Paving Type 6Brick Paving

PIT Proposed Service Pits

RW1 Brick base with a Timber capping Retaining wall

RW2 Brick base with a Precast concrete capping Retaining wall

RW3 Insitu concrete Retaining wall

ST1 Corten Steel Edging

TD1 Timber Bench Seats

TD2 Timber Composite vertical batten screen

TD3 Timber Decking

LP1 Lighting strip

BO1 Stainless steel Bollard

S STUDIO

1B 1 BED

1BM 1 BED + MEDIA NOOK

1BS 1 BED + STUDY

2B 2 BED

2BM 2 BED + MEDIA NOOK

2BS 2 BED + STUDY

2BK 2 BED DUAL KEY

2BT 2 BED 2 STOREY TERRACE

3B 3 BED

3BM 3 BED + MEDIA NOOK

3BS 3 BED + STUDY

4B 4 BED

RETAIL + NON-RESIDENTIAL

CHILDCARE

EXTERNAL AREA

COURTYARD/BALCONY/WINTER-GARDEN

2 HOURS OF SUNLIGHT ACCESS

NATURAL VENTILATION (NV)

WIDE FRONTAGE NATURALLY VENTILLATED

ASSISTED VENTILATION

SOUTH FACING APARTMENT

ADAPTABLE APARTMENT

LOBBY DUCTED VENTILATION

APARTMENT ASSIST VENT DUCT

ASSISTED VENTILATION

GOOD VENTILATION

NATURAL VENTILATION

LOBBY CROSS VENTILATION

RW4 Heritage Interpretation wall

FAC12 Profiled anodised aluminium vertical batten using "clip-on" fixingas noted in elevation (to stairs)Fixed horizontal glass louvresFAC13

BS01 Balustrade Type 01

CCTV Camera

Frasers Broadway

Suite 11, Lumiere Commercial,Level 12, 101 Bathurst Street,Sydney, NSW, 2000, Australia

Frasers Broadway

Suite 11, Lumiere Commercial,Level 12, 101 Bathurst Street,Sydney, NSW, 2000, Australia

NATURAL VENTILATION

DW

DW

E-13081B

W &

D

FS-04-13Fire Stair

F

F

F

W &

D

W &

D

W & D

W &

D

W &

D

W & D

W &

D

W & D

F

F

F

F

F

01SSDA-11-302

01SSDA-11-302

01SSDA-11-302

01SSDA-11-302

FH

01SSDA-11-301

01SSDA-11-301

L-01LIFT

L-02LIFT

E-13013B

E-13032B

E-13022BM

E-13071BS

L-01LIFT

L-02LIFT

E-1300Corridor

E-1300Lobby

Bin Room

SPSP

CHWHHW

FH

RKE

FH

GRVENT

CKE

RKE

LRAFE

BPV

M LRARKERKE

LSA FS HYDCOMMS

HYDELEC HYD

HYDFS

HYD

FE

P-1301Hydraulic PlantRoom

01SSDA-11-401

02SSDA-11-401

02SSDA-11-402

01SSDA-11-402

F

DW

DW

DW

DW

DW

BLOCK 11 LOT BOUNDARY

E-13041BM

X1

A

A

B

B

C

C

D

D

E

E

F

F

G

G

H

H

I

I

1 1

4 42020

2121

2222

Y1

Y2

Y3

XB

X1

XC

XD

2424

31

O

O

P

P

Q

Q

S

S

T

T

U

U

V

V

ZFZE

ZDZC

ZBZA

30

2525

2 2

3 3

R

R

SC

SD

SE

EA

EA

FA

FA

GA

GA

32

J

J

K

K

L

L

M

M

DA

DA

UA

UA

2323

33

FA

FA

DP

DP

DP

DP

DP

DP DP

DP

DP

DP

E-13052BM

E-13061BM

E-13091B

FS-06-13Fire Stair

0 2.5 5 10m

LEGEND

C FRANCIS-JONES MOREHEN THORP PTY LTD 2017 ABN 28 101 197 219

GENERAL NOTESALL DIMENSIONS AND EXISITNG CONDITIONS SHALL BECHECKED AND VERIFIED BY THE CONTRACTOR BEFOREPROCEEDING WITH THE WORK

ALL LEVELS RELATIVE TO 'AUSTRALIAN HEIGHT DATUM'

DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY

SHEET NO.

DATE

SCALE

APPROVED

DRAWN PROJECT CODE

TITLE

PROJECT

REVISION

Central Park Block 11O'Connor Street, ChippendaleSydneyFrasers Broadway

PLANSLevel 13

Issued for Approval

FB1124/10/2014

1:250 @ A1

SSDA-11-210 05

FJMT

SB

SYDNEYLevel 5, 70 King Street

Sydney NSW 2000 AustraliaT +61 2 9251 7077F +61 2 9251 7072

E [email protected] www.fjmt.com.au

NOMINATED ARCHITECT: RICHARD FRANCIS-JONES (REG NO 5301)

ARCHITECT

CLIENT

REV. DATE DESCRIPTION BY

01 1:250PLAN Level 13

WHEN PRINTED AT 50% ON A3 THE SCALE IS 1:500

02 03/07/2015 REFER REVISION CLOUDS FJMT01 24/10/2014 ISSUED FOR SSDA APPROVAL FJMT

03 21/06/2016 REVISED SSDA FJMT04 01/12/2016 ISSUED FOR S96 APPROVAL FJMT05 08/09/2017 ISSUED FOR S96 APPROVAL FJMT