Central Pollution Control Board HWM Division, Delhi Sub: Minutes of the Thirteenth Meeting of the Technical Expert Committee for "Evaluation of proposal for utilization of the hazardous wastes under Rule 11 of the Hazardous Waste (Management, Handling & Transboundary) Rules, 2008". The Thirteenth Meeting of the Technical Expert Committee on "Evaluation of proposals for utilization of the hazardous wastes as a supplementary resource or for energy recovery, or after processing" was held at CPCB, Delhi on 27/08/2014. List of the participants is enclosed at Annexure I. Shri B. Vinod Babu, I/c HWMD, welcomed the members and invitees of the Committee and informed that 24 applications (new cases) have been received for approval for utilization of HW under Rule 11 of the HWM Rules, 2008. The list of applicants considered for placing before the TEC is given at Annexure-II The recommendations of the committee on the new proposals discussed in the meeting are given at Annexure —III A & B. The recommendations of the committee based on the findings of the trial runs/ joint inspections carried out by CPCB and SPCB are given at Annexure — IV. 5. The recommendations of the committee regarding grant of renewal permission for utilization of hazardous waste subsequent to the inspection by CPCB are given at Annexure — V. 6. The meeting ended with vote of thanks to the Chair. 1

Upload: others

Post on 07-Nov-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Central Pollution Control Board HWM Division, Delhi

Central Pollution Control BoardHWM Division, Delhi

Sub: Minutes of the Thirteenth Meeting of the Technical Expert Committee for"Evaluation of proposal for utilization of the hazardous wastes under Rule 11 ofthe Hazardous Waste (Management, Handling & Transboundary) Rules, 2008".

The Thirteenth Meeting of the Technical Expert Committee on "Evaluation of proposalsfor utilization of the hazardous wastes as a supplementary resource or for energyrecovery, or after processing" was held at CPCB, Delhi on 27/08/2014. List of theparticipants is enclosed at Annexure I.

Shri B. Vinod Babu, I/c HWMD, welcomed the members and invitees of the Committeeand informed that 24 applications (new cases) have been received for approval forutilization of HW under Rule 11 of the HWM Rules, 2008. The list of applicantsconsidered for placing before the TEC is given at Annexure-II

The recommendations of the committee on the new proposals discussed in the meetingare given at Annexure —III A & B.

The recommendations of the committee based on the findings of the trial runs/ jointinspections carried out by CPCB and SPCB are given at Annexure — IV.

5. The recommendations of the committee regarding grant of renewal permission forutilization of hazardous waste subsequent to the inspection by CPCB are given atAnnexure — V.

6. The meeting ended with vote of thanks to the Chair.

1

Page 2: Central Pollution Control Board HWM Division, Delhi

Annex re I

CENTRAL POLLUTION CONTROL BOARDDELHI- 110 032

Date: August 27, 2014

Venue: 2nd Floor, Conference room,Parivesh Bhawan, CPCB, Delhi- 110 032

Thirteenth Meeting of the Technical Expert Committee for Evaluation of proposal for utilization of thehazardous wastes as a supplementary resource or for energy recovery, or after processing

List of Participants

S. No Name Designation Member of the Committee /Invitee

Shri R.K. Garg Former Managing Director, Indian RareEarths Ltd.

Chairperson

Shri. K.P. Nyati - Member

3. Dr. Tapan Chakraborty Ex-Director, National EnvironmentalEngineering Research Institute (NEERI),Nagpur

Member

Dr. I. Hag Ex- Additional Director, Central PollutionControl Board

Member

Shri R. K. Vashist Sr. Advisor, PDIL, Noida Representing Member of thecommittee on behalf of PDIL

Sh. B. Vinod Babu Senior Environmental Engineer & I/cHWMD, CPCB, Delhi

Member Convener

Sh. Bharat K Sharma Senior Environmental Engineer, HWMD,CPCB, Delhi

Invitee

Sh. G. Rambabu Environmental Engineer (HWMD), CPCB,Delhi

Invitee

Ms. Deepti Kapil Environmental Engineer (HWMD), CPCB,Delhi

Invitee

2

Page 3: Central Pollution Control Board HWM Division, Delhi

Annexure-Il:

The list of applications considered for discussion in the 13th meeting of TEC

I. List of new cases (all called for technical presentation)

S. No. Name & addressM/s. J.S Enterprises, Plot No 12,45, 1314-A & 14-B, Jai Road, Atodara-394130, Tal: Olpad, Distt:Surat, GujaratM/s Fertile India Agrotech Ltd., K-2, Textile Colony, Industrial Area A, Ludhiana, Punjab - 141003M/s The Fertilizers & Chemicals Travancore Ltd., Cochin Division, Ambalamedu- 682303M/s Bijaya Aluminiums, S-3/34, Macheshwar Industrial Estate,BhubaneswarM/s. A.K Enterprises , 105, Sector-A, Zone-B, Macheshwar Industrial Estate,BhubaneswarM/s. Spiro Intermediates Pvt. Ltd., C-6, PIPDIC Industrial Estate,Kirumampakkam, PuducherryM/s. Rishab Intermediates Pvt. Ltd., A-70, PIPDIC Industrial Estate, Sedaraper, PondicherryM/s. Premier Chemical Industries, S.F. No. 123/8B, 9A, Thuthipet Village & Post, Villianur Commune,PuducherryM/s. Swastik Tungsten Pvt. Ltd., Plot No. C-4/15, MIDC, Shrirampur, Distt-Ahmednagar- 413709M/s. Sai Metallik, At- Jamunalia, PO- Badaposhi, Via-namapur, Distt- Keonjhar, Odisha — 758014M/s. Shubham Sales Co., 5.3 Km Milestone, Rohtak Bhiwadi Road, HaryanaM/s Vandana Chemicals, Plot No. 7409, GIDC, Ankleshwar, Gujarat - 393002M/s. Dhoriyani Glass & Ceramics, S. No. 767/2 & 3, Lakhdhirpur Road, Taluka — Morbi, Dist-Rajkot,GujaratM/s. Swastik Industries, Plot No- 177/1, Dhuva, Tehsil — Wankaner, Distt Rajkot, GujaratM/s. Pearl Industries, Plot No Survey No. 123/1, Village- Rangapur, Nr Roland Ceramic, Jetpar Road,Rangpar, Tal, Morbi, Dist — Rajkot, Gujarat- 363642M/s. Nobel Cesa Coat, Plot No — 8-A, National Highway, Juna Jambudiya, Tal — Morbi, Dist —Rajkot, Gujarat — 363641M/s. Balaji Ceramics, Plot no 231, GIDC Rafleshwar Estate, Vill Morbi, Tehsil-Morbi, Distt-Rajkot,Gujarat — 363642M/s. Unique Cera Coat Industries, Plot No. S.No 8, Lilapur Road, At Lilapur, Taluka — Morbi,Distt- Rajkot, Gujarat 363641M/s. Galaxy Glass Industries, S. No. 153, 8A National Highway, At Lalpur, Taluka- Morbi, Distt-RajkotGujarat — 363641M/s. Matrix Cera Enamel Co., Plot No. 226, GIDC Rafleshwar, N. H. 8A, Rafleshwar Tal - Morbi, Distt-Rajkot, Gujarat — 363642M/s. Pooja Ceramic Pvt. Ltd., Plot No. 6, 8-A, National Highway, At Trajpar, Taluka- Morbi, Distt-Rajkot, Gujarat- 363642M/s. Glass Tech, 116/P-2, 8 A, National Highway, At. Sartanpar, Tal. Wankaner, Dist-Rajkot, Gujarat-363622M/s Arth Metallurqicals Pvt. Ltd., Plot No. 95/2 KH No. 226/1, Lalpur, Dharshiva, Raipur, ChhattisgarhM/s Shiv Shakti Enetrprises, Mauja Chakjangi, Khasra No. 42, Village Chakjangi, Baddi,Tehsil Nalagarh, Distt-Solan (H.P)

II. List of old cases (called for presentation as decided in earlier TEC meeting)

S. No. Name of the Industry

M/s Teesta Agro Industries Ltd. Vill.- Mazabari, P.O.- Rajganj, Dist.- Jalpaiguri, West BengalM/s Triveni Enterprises, E-27, Udyoq Kunj Industrial Area, Distt- Ghaziabad (U.P)M/s Jarad Chemicals, Plot No. C1B/416, GIDC, Ankleshwar — 393002, Bharuch, GujaratM/s Philips Electronics India Limited, Industrial Focal Point, Phase-IX, S. A. S. Nagar, Mohali, Punjab

5. M/s JSW Steel Limited, Salem Works, Pottaneri Kalipatti Village, Mecheri, Mettur taluk, Salem(TamilNaidu)

Ill. The list of cases pertaining to grant of approval for a period of one year;

S. No Name of the Industry

„1.!1. M/s Ambica Industries, Cl/B 457, G.I.D.C. Estate, Sachin, Surat — 394230, Gujarat

IV. The list of cases pertaining to renewal;

S. No Name of the Industry

M/s Dielectric Corporation, F/92, Industrial Area, Govindpura, Bhopal- 462 030M/s Sumak Pigments, A-25 Manjusha Manohar garden, jai Bhavani Road,Nashik - 422102

3

Page 4: Central Pollution Control Board HWM Division, Delhi

Annexure III -A

Recommendation of the Committee for New proposals for approval under Rule 11 of theHazardous Waste (Management Handling & Transboundarv) Rules. 2008.

S.No

Name of the Industry HW as RawMaterial &Product

Process Recommendations

M/s. J.S Enterprises,Plot No 12,45, 1314-A & 14-B, Jal Road, Atodara-394130, Tal: Olpad, Distt:Surat, Gujarat

Contaminated/ Discardedcontainers/barrel / useddrums &Bags/Linersfor re-use

Cleaning ofContaminated drumswith detergent/causticsolution and water forreuse

The committee recommended cleaning ofcontaminated drums received fromindustries, as per guidelines attachedherewith (Annexure- VI) after inspectionby CPCB and GPCB. Further, the cleaningof drums with solvent is not permitted.

So far as solvent recovery is concerned,the matter will be considered only afterCTE/CTO is obtained from the concernedSPCB.

The committee did not agreed for cleaningof bag/liners for reuse.

M/s Fertile India AgrotechLtd.,K-2, Textile Colony,Industrial Area A,Ludhiana, Punjab - 141003

Spentsulphuric acidgeneratedfrom picklingoperationtobe utilized formanufacturingFerrousSulphate

Reaction of iron dustand spend sulphuricacid in a reactionvessel followed by filterpressing andcrystallization

The committee has earlier recommendedutilization of Spent sulphuric acid formanufacturing Ferrous Sulphate fortreatment of wastewater. In this case also,the unit is proposing to use of soent acidgenerated from pickling operation forFerrous Sulphate production.The committee therefore recommendsutilization of spent sulphuric acidgenerated from pickling operation in theproducing Ferrous Sulphate with sameprovisions after verification of the facilityby CPCB and SPCB.

M/s The Fertilizers &Chemicals Travancore Ltd.,Cochin Division,Ambalamedu- 682303

Sulphur muckto be utilizedformanufacturingComplexFertilizer

Sulphur muckgenerated from its ownplant will be grinded to1-4 mm size. 0.1 % ofthis powered sulphurmuck is then mixedwith complex fertilizer.

The committee recommends utilization ofthe sulphur-muck subject to verification ofgrinding and mixing facilities byCPCB/SPCB officials.

M/s Bijaya Aluminiums,S-3/34, MacheshwarIndustrial Estate,Bhubaneswar - 10

Aluminiumdross utilisedformanufacturingof AluminiumUtensil

The aluminium dross isPulverized, screenedand melted in cokefired small oven toproduce Aluminiumutensil

The proponent did not attend the meeting.

The committee therefore decided to inviteproponent in next meeting to explainprocess details alongwith information assought by CPCB to enable the committeeto evaluate the same.

5. M/s. A.K Enterprises105, Sector-A, Zone-B,Macheshwar IndustrialEstate,Bhubaneswar

Aluminiumdross utilisedformanufacturingof AluminiumUtensil

During presentation it was stated that theprocess involved is pulverising andscreening to remove metal and thegangue material. The metal part is thenmelted to recover about 80-85 % asAluminium metal. Overall recovery fromthe dross is reported between 15-25 %.The residual material 75-85 % will be sentto TSDF.

The committee therefore recommend forconducting trial run for a period of 10 daysduring which CPCB will conduct samplingand analysis.

c2)0 -1/1

4

Page 5: Central Pollution Control Board HWM Division, Delhi

'S.No

NatrA of the Industry HW as RawMaterial &Product

Process Recommendations

M/s. Sai MetallikAt- Jamunalia, PO-Badaposhi,Via-narnapur, Distt-Keonjhar,Odisha — 758014

Aluminiumdross utilisedformanufacturingof AluminiumIngots

The aluminium dross isPulverized, screenedand melted in cokefired small oven toproduce Ingots

The unit vide email dated 25/08/2014requested to consider their proposal innext meeting since the plant andmachinery are yet to be installed.

The committee recommended to giveanother opportunity to appear in the nextmeeting of this committee along withdetails on the plant & machinery installed.

M/s. Spiro Intermediates Pvt.Ltd.,C-6, PIPDIC IndustrialEstate,Kirumampakkam,Puducherry - 607402

WasteDichromatesolution to beutilized formanufacturingBasicChromiumSulphate

Waste Dichromatesolution is mixed withsodiumdichromate/calcite andreducing agent sodiumsulphate and causticsoda/soda ash toproduce BasicChromium Sulphatesolution which isfurther dried

After the presentation, committee askedfor the following additional information:

Complete analysis of the wastesodium dichromate solution w.r.tCr.3, Crab , TOC and any otherinorganic salts.Analysis of gypsum in respect ofchromium content (Cr+3 , Cr'6)

3. Chromium balance in theprocess.

The committee also suggested forconducting trial run in presence of CPCBand PPCC in order to assess theenvironmental issues, if any.

M/s. Rishab IntermediatesPvt. Ltd., A-70, PIPDICIndustrial Estate, Sedaraper,Pondicherry — 605111M/s. Premier ChemicalIndustries , S.F. No. 123/8B,9A, Thuthipet Village & Post,Villianur Commune,Puducherry — 605502M/s. Swastik Tungsten Pvt.Ltd., Plot No. C-4/15, MIDC,Shrirampur, Distt-Ahmednagar- 413709

Cobalt sludgeto be utilizedformanufacturingcobalt

The wet cobalt sludgegenerated from its ownplant will be dried inelectric heated furnaceto produce dry cobalt.

During presentation it was found that theunit is proposing to utilize tungsten carbidescrap obtained from various userindustries. The committee observed thatthis item is not covered in Schedule 1 ofHWM Rules, 2008. Since tungstenappears in category B of Schedule-II astungsten compound, the committeerecommended that TCLP test may beconducted as per the method prescribedunder the said Rules. In case tungsten<5000 mg/kg, the permission under Rule 11will not be applicable and the unit may beinformed accordingly.

M/s. Shubham Sales Co.,5.3 Km Milestone, RohtakBhiwadi Road,Haryana

Used Oil andCarbon slurryto be utilizedformanufacturingcarbon pellets

Mixing of used oil andcarbon slurry toproduce carbon pallets.

During presentation the committee wasinformed that the unit is proposing to takecarbon slurry from NFL, Panipat, toprepare carbon black granules for use inrubber industry. The committee had earlierrecommended use of similar carbon slurryby carbon black manufacturer.

The committee recommended theutilization of carbon slurry provided usedoil is not used in the process and the unitinspected by CPCB and SPCB to look intoany environmental issues.

`t_cp,s2V

5

Page 6: Central Pollution Control Board HWM Division, Delhi

S.No

NEW" of the Industry HW as RawMaterial &Product

Process Recommendations

M/s Vandana ChemicalsPlot No. 7409, GIDC,Ankleshwar,Gujarat - 393002

Spentbromidesolution to beutilized formanufacturingBromine

Reaction of Spentbromide solution,sulphuric acid andchlorine gas in areaction vesselfollowed bycondensation

The unit has not responded to CPCB'sletters dated 16.07.2014 and 22.08.2014for submission of the requisite information/documents and making technicalpresentation before the Technical ExpertCommittee (TEC).

It was recommended that the unit may begiven a final opportunity to respond within30 days failing which the proposal shall bedeemed to be withdrawn by the applicant.

Upon submission of the relevantinformation/document proponent may beinvited for making technical presentation inthe next meeting.

M/s. Dhoriyani Glass &Ceramics,S. No. 767/2 & 3,Lakhdhirpur Road,Taluka — Morbi, Dist-Rajkot,Gujarat-363642

Tarry Residueto be utilizedas asupplementary fuel infurnace tomanufactureCalcium glazefrit

Tarry residuegenerated from coalgasifier units and steeland power plants isused directly as fuelalongwith quartz,feldspar, calcite, sodaash in furnace toproduce Ceramic glazefrit.

conditions;

The committee observed that trial run hadalready been carried out for utilization ofsimilar hazardous waste in case of the Eightunits located in Morbi area of Gujarat.However, scrubber was installed in all thoseunits whereas no such APCDs have beeninstalled in these 10 units.

In view of above, the committeerecommended to carry out trial run inpresence of CPCB & GPCB officials in anytwo units, one out of which with scrubber andthe other without scrubber for performanceevaluation with and without scrubber.

In case, the above trial run reportdemonstrate compliance with stipulatedstandards (other than NOx, if applicable) inunit without scrubber, installation of scrubbermay not be required. However, if it compliesonly in unit having scrubber, all the otherunits shall be asked to install scrubber.Permission may accordingly be given forutilization of tarry residue in furnace for aperiod of one year with the following

I GPCB may review NOx standard for thiskind of material.

Tarry residue to be injected into furnaceonly after the furnace achieves morethan 1400°C by using conventional fuels(FO/ LDO/ PNG/ CNG etc.)

Only electrical heaters should be usedfor heating the tar for liquefaction.

iv. Fumes if any released during heatingshould be channelized as combustion airto furnace.

In case, the trial run demonstrates non-compliance in both the units, the report shallbe discussed in the next committee meeting.

M/s. Swastik Industries,Plot No- 177/1, Dhuva,Tehsil — Wankaner, DisttRajkot,Gujarat — 363642M/s. Pearl Industries,Plot No Survey No. 123/1,Village- Rangapur, NrRoland Ceramic,Jetpar Road, Rangpar, Tal,Morbi,Dist — Rajkot, Gujarat-363642M/s. Nobel Cesa Coat,Plot No — 8-A, NationalHighway,Juna Jambudiya, Tal —Morbi,Dist — Rajkot, Gujarat —363641M/s. Balaji Ceramics,Plot no 231, GIDCRafleshwar Estate,Vill Morbi, Tehsil-Morbi,Distt-Rajkot,Gujarat — 363642M/s. Unique Cera CoatIndustries,Plot No. S.No 8, LilapurRoad,At Lilapur, Taluka — Morbi,Distt- Rajkot, Gujarat 363641

.M/s. Galaxy Glass Industries,S. No. 153, 8A NationalHighway,At Lalpur, Taluka- Morbi,Distt-Rajkot Gujarat —363641

6

Page 7: Central Pollution Control Board HWM Division, Delhi

S.No

Nar-9 of the industry HW as RawMaterial &Product

Process Recommendations

M/s. Matrix Cera EnamelCo.,Plot No. 226, GIDCRafleshwar, N. H. 8A,Rafleshwar Tal - Morbi, Distt-Rajkot,Gujarat - 363642M/s. Pooja Ceramic Pvt. Ltd.,Plot No. 6, 8-A, NationalHighway,At Trajpar, Taluka- Morbi,Distt- Rajkot, Gujarat-363642M/s. Glass Tech,116/P-2, 8 A, NationalHighway,At. Sartanpar, Tal.Wankaner, Dist-Rajkot,Gujarat-363622M/s Arth Metallurgicals Pvt.Ltd., Plot No. 95/2 KH No.226/1, Lalpur, Dharshiva,Rai pur, Chhattisgarh

Vanadiumsludge to beutilized formanufacturingVanadiummetal

Leaching of vanadiumsludge with ammoniumchloride followed byneutralization, filtration,centrifuging, drying toproduce vanadiummetal

The committee recommended for trial runfor a period of 10 days during whichinspection and monitoring will be carriedby CPCB and SPCB officials. In particularemission of ammonia and disposal ofwastewater containing sodium chloride,ammonium chloride, vanadium and otherheavy metals have to be verified.

24. M/s Shiv ShaktiEneterprises, MaujaChakjangi, Khasra No. 42,Village Chakjangi, Baddi,Tehsil Nalagarh, Distt-Solan(H.P)

Contaminated/ Discardedcontainers/barrel / useddrums for re-use

Cleaning ofContaminated drumswith detergent/causticsolution and water forreuse

The unit has already been visited in linewith the uniform protocol (recommendedin the earlier TEC meeting) by the officialsof RO HP SPCB. The report on the sameas received from HP SPCB was discussedand it was recommended to grantapproval for utilization of Contaminated/Discarded containers /barrel / used drumsfor re-use for initial period of one year withthe conditions based on the reportsubmitted by HP SPCB.

7

Page 8: Central Pollution Control Board HWM Division, Delhi

Annexure 111-B

Recommendation of the Technical Expert Committee on Old Cases for approval under Rule 11 of theHazardous Waste (Management. Handling & Transboundarv) Rules. 2008

S.No Name of the Industry

HW utilized &Product

manufacturedBackground Recommendations

M/s Triveni EnterprisesE-27, Udyog KunjIndustrial Area, Distt-Ghaziabad (U.P)

Spent Solvent to beutilized formanufacturingThinner

In compliance with therecommendation of theearlier meeting, theapplicants are invited toexplain process detailsalongwith informationsought by CPCB to enablethe committee to evaluatethe proposals.

The committee observed thatthe applicant neithersubmitted the information assought by CPCB nor attendedthe meeting despite of severalreminders.

In view of above, thecommittee recommended thatthe unit may be given a finalopportunity to respond within30 days failing which theproposal shall be deemed tobe withdrawn by the applicant.

Upon submission of therelevant information/documentproponent may be invited formaking technical presentationin the next meeting.

M/s Jarad Chemicals,Plot No. C1 B/416, GIDC,Ankleshwar -393002Bharuch, Gujarat

Spent Solvents tobe utilised formanufacturingSolvents

3. M/s Teesta AgroIndustries Ltd. Vill.-Mazabari, P.O.- Rajganj,Dist.- Jalpaiguri, WestBengal

Sulphur Sludge andSSP/SAP Cleaning& Scrubbing residueto be utilized formanufacturingSingle SuperPhosphate

The committee recommendsutilization of the sulphursludge subject to verificationof grinding and mixingfacilities by CPCB/SPCBofficials.

tsv,—(2A-v

8

Page 9: Central Pollution Control Board HWM Division, Delhi

Annexure IV

Recommendation of the Technical Expert Committee on Grant of approval after trial run under theprovision of Rule 11 of the Hazardous Waste (Management, Handling & Transboundarv) Rules. 2008

S.No Name of the Industry HW as Raw

Material& Product

Background Recommendations

M/s Philips Electronics IndiaLtd, Phase- 9, Industrial Area,Sas Nagar, Mohali -160 062,Punjab

Spent Acid containingMolybdenumcompound, (which isin-house generated)to be utilized forproduction ofMolybdenum Trioxide.

In compliance with earlierrecommendations of thecommittee, the representativeof the unit was invited seekingclarification on chemistryinvolved in crystallization ofmolybdenum trioxide, mode ofdisposal of residual sulphuricacid and effluent from thescrubber.

Base on the presentationand discussion, itemerged that afterrecycling, the nitric acidand sulphuric acid goingin the effluent streamwould be about 8 kgs ofnitric acid and 43 kgs ofsulphuric acid in a batchof 12 kg Molybdenum.

Therefore, the committeerecommends that nitricacid to be scrubbed asammonium nitrate whichcan be used as fertilizer.The spent sulphuric acidcould be send to ETP forneutralization with lime,so that gypsum sogenerated can bedispose to TSDF orexplore the option forutilizing the same incement plant.

Upon installation ofaforesaid additionalfacilities and verificationof same by CPCB,permission for utilizationmay be given for aperiod of one year.

M/s JSW Steel Limited,Salem Works, PottaneriKalipatti Village, Mecheri,Mettur taluk, Salem-636453Tamil Naidu

Iron Oxide (Processwaste) from Illmenitechemical beneficiationplant

In compliance with earlierrecommendations of thecommittee, the representativeof the unit was invited forunderstanding the remedialstep w.r.t exceedance of HCI,Acid mist and PM in theemissions.

The applicant intimatedtheir inability to attendthe meeting andrequested to considertheir case in the nextmeeting.

The committee thereforerecommended that theunit may be givenanother opportunity toappear in the nextmeeting of thiscommittee.

3. M/s Ambica Industries, C1/B457, G.I.D.C. Estate, Sachin,Surat — 394230, Gujarat

Spent solvent to beutilized formanufacturing ofDistilled mixedsolvents

In compliance with earlierrecommendations of thecommittee, the unit was jointlyvisited by the officials of CPCBand West Bengal SPCB. Theinspection report received fromCPCB Zonal Office may bediscussed for grant of approvalfor an initial period of one year

Based on the report it isobserved that there arenumber of deficiency inthe existing systemparticularly in respect ofemission of VOCs toenvironment. Adequatesteps have to be takenlike provision ofsecondary chilled water

. r 9

Page 10: Central Pollution Control Board HWM Division, Delhi

S.No Name of the Industry HW as Raw

Material& Product

Background Recommendations

cooled condenser bothfor the process vent aswell as the storage tank.

Upon receipt ofconfirmation ofinstallation of theadditional system asabove and verification ofthe same, permission forutilization of SpentSolvent @ 210MT/month for a period ofone year may be given.

10

Page 11: Central Pollution Control Board HWM Division, Delhi

4

Annexure V

Recommendation of the Technical Expert Committee on Renewal Permission of Grant under the provisionof Rule 11 of the Hazardous Waste (Management. Handling & Transboundarv) Rules. 2008

S.No Name of the Industry HW as Raw Material

& Product Background Recommendations

M/s Dielectric Corporation,F/92, Industrial Area,Govindpura, Bhopal- 462 030

Resin waste to beutilized formanufacturing ofHT/LT insulators

The unit was initiallygranted one yearpermission forutilization ofrespective hazardouswaste. Theapplications forrenewal of permissionwere forwarded toCPCB Zonal Office forinspection/verificationand submit reportalong withrecommendations.The report on thesame has beenreceived and thematter is placedbefore the committeeto discuss grant ofrenewal permission.

The committee recommendedrenewal of permission withvalidity period of 5 years forutilization of resin waste @ 2MT/annum.

M/s Sumak PigmentsA-25 Manjusha Manohargarden, jai BhavaniRoad,Nashik - 422102

Spent acid containingMolybdenumcompound formanufacturingAmmonium andSodium Molybdate

As per the earlierrecommended thatrenewal permissionfor utilization of SpentAcid (containingMolybdenumcompound) wasinitially granted for 6months.Later the unit appliedfor renewal ofpermission informingabout installation ofETP. Zonal Office,CPCB was requestedto send report in thisregard.

Inspection report fromZonal Office, CPCB,has been receivedand placed before thecommittee fordiscussion.

Based on the inspection reportthe committee observed thatETP has been installed.

The committee thereforerecommends renewal ofpermission for a period of 5year. The treated effluent shallbe dispose as per the conditionas may be stipulated byMaharashtra SPCB.

Da,

11

Page 12: Central Pollution Control Board HWM Division, Delhi

Annexure —VI

Protocol for cleaning of contaminated drums/containers/ barrels for re-use and manufacturing ofplastic granules:

The drums containing solid material may be taken into cleaning process and in case of liquids, only selected list of chemicalscontaining drums may only be permitted. Such list to be prepared by CPCB in consultation with generating industry and SPCB.

The unit shall provide details on type of industries from where contaminated drums/ container shall be procured alongwith thedetails on the content of the material stored.

The units involved in cleaning of contaminated drums/containers/barrels should have the following minimum requirements;

A. Handling and Storage

Separate covered storage area for both contaminated containers and cleaned containers. There should be proper slopeand spillage collection pit.

The manifest system and logbook should be maintained. Labeling should be done on all contaminated drums indicatingsource and date of receipt and type of drum

3. Prior to cleaning, the left-over or residual material in the drums should be transferred into a separate container for safestorage and disposal at TSDF.

B. Cleaning Procedure

All the drums should be cleaned with hot caustic solution up to 2% concentration or detergent.

There should be two stage cleaning i.e. caustic /surfactants (detergent) cleaning followed by fresh water cleaning.

Provide parapet wall along the container storage and washing area.

The number of nozzles in 1 HP pump shall not exceed 3.

The nozzles should be modified with multiple jets to ensure that water jets hit whole inner surface of the containers.

There should be separate area with provision of hose pipe with spray nozzle for washing outer surface of the containers.

C. Effluent Treatment

Flow through evaporator should be regulated based on heating capacity of the evaporator. Water flow meter should beinstalled at the inlet to evaporator and at the inlet to ETP.

The vent of vacuum pump should be elevated at least up to 2 mtr above the roof level

The units should ensure zero discharge by evaporation of the effluent.

Incase of availability of CETP, the units shall become members of the same and send their effluent for final treatment anddisposal

D. Labeling of Cleaned drums for re-use

The labels on the washed containers for re-use should be removed (preferable with a paint) and the cleaned containersshould be labeled with prominent indelible text

"Drum Cleaned by : M/s • Date:

"For industrial use only

NOT for storing any food material"

The above is not applicable in case the cleaned drums are shredded and re-cycled.

12