centre spatial de liège université de liège © centre spatial de liège 2002 1 high resolution...
TRANSCRIPT
1
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
High Resolution Dynamic HolographyHigh Resolution Dynamic Holographywith Photorefractive Crystals :with Photorefractive Crystals :
Principles and Applications to Vibrations Principles and Applications to Vibrations MeasurementMeasurement
Marc GEORGES, Centre Spatial de LiègeMarc GEORGES, Centre Spatial de Liège
2
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
Holographic InterferometryHolographic Interferometry
Full-field, non-contact techniqueFull-field, non-contact technique Displacements measurement : 10 nm - 25 microns (one shot)Displacements measurement : 10 nm - 25 microns (one shot) Higher resolution compared to Speckle-basedHigher resolution compared to Speckle-based Needs of potential userNeeds of potential user
Easy to set upEasy to set up Quantified data, easy to interpreteQuantified data, easy to interprete Transportable/portable, compact, robust, flexible, …Transportable/portable, compact, robust, flexible, … Configuration adaptableConfiguration adaptable Cheap, low consumptionCheap, low consumption
3
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
Real-time Holographic InterferometryReal-time Holographic Interferometry
I(x,y)=I0(x,y) [1+m(x,y) cos((x,y))]InterferogramInterferogram
Holographic InterferometryHolographic Interferometry
4
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
Critical segment for applicability : Holographic mediumCritical segment for applicability : Holographic medium– FastFast
– Homogeneous (optical quality)Homogeneous (optical quality)
– Processable in-situProcessable in-situ
– Erasable, reversibleErasable, reversible
– Low diffusion noise (high signal-noise ratio)Low diffusion noise (high signal-noise ratio)
– No or fewest operations possible for obtaining informationNo or fewest operations possible for obtaining information
Holographic InterferometryHolographic Interferometry
5
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
Photorefractive crystalsPhotorefractive crystals
Local space charge fieldLocal space charge field
created between dark created between dark
and illuminated areaand illuminated area
1.1. Fringe pattern created by Fringe pattern created by interference between 2 wavesinterference between 2 waves
2.2. Charges generated byphoto-excitation in illuminated area,Charges generated byphoto-excitation in illuminated area,
migrate and are trapped in dark areamigrate and are trapped in dark area
6
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
3. Electro-optic effect (Pockels)3. Electro-optic effect (Pockels)
Refractive index Refractive index nn is modulated by space-charge field is modulated by space-charge field
Recording of a volumic refractive index grating Recording of a volumic refractive index grating (thick (thick hologram)hologram)
4. Processus is dynamic and reversible4. Processus is dynamic and reversible
In-situ recordingIn-situ recording
Erasure possible = Re-recordingErasure possible = Re-recording
Photorefractive crystalsPhotorefractive crystals
7
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
Crystal familiesCrystal families– Sillenites : BiSillenites : Bi1212SiOSiO2020 (BSO), Bi (BSO), Bi1212GeOGeO2020 (BGO), Bi (BGO), Bi1212TiOTiO2020 (BTO) (BTO)
– Ferroelectrics : LiNbOFerroelectrics : LiNbO33, BaTiO, BaTiO33, KNbO, KNbO33, KTN, SBN,…, KTN, SBN,…
– Semiconductors : CdTe, ZnTe, AsGa, InP,…Semiconductors : CdTe, ZnTe, AsGa, InP,…
Figures of meritFigures of merit
n = nsat (1-exp(-t/))
– Recording energy at saturation : ERecording energy at saturation : Ess = = .I.I
– Diffraction efficiency : Diffraction efficiency : = I= Idiffdiff/I/Irefref ~ ( ~ (n)n)22
Photorefractive crystalsPhotorefractive crystals
8
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
Particular properties : depend on crystal cutParticular properties : depend on crystal cut
θ θ
Photorefractive crystalsPhotorefractive crystals
Γl =4πΔnlλ
≈1
a
P2P1PdiffPt
Anisotropic diffraction Isotropic diffraction
Interferogram contrast depends on the analyser orientation Interferogram contrast depends on the product :-coupling constant-crystal thickness
9
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
Sillenites : BSO - BGO - BTOSillenites : BSO - BGO - BTOSensitive in blue-green, red with dopantsSensitive in blue-green, red with dopants
EESS ~ 1-10 mJ/cm ~ 1-10 mJ/cm22, , ~ 0.1 %, ~ 0.1 %, ~ 0.5 cm~ 0.5 cm-1-1
Ferroelectrics : LiNbOFerroelectrics : LiNbO33 - KNbO - KNbO33 - BaTiO - BaTiO33 - SBN ... - SBN ...Sensitive blue-green, red-near IR with dopantsSensitive blue-green, red-near IR with dopants
EESS ~ 1-10 J/cm ~ 1-10 J/cm22, , ~ 100 %, ~ 100 %, ~ 1 - 40 cm~ 1 - 40 cm-1-1
Semiconductors : CdTe - ZnTe - CdZnTe .…Semiconductors : CdTe - ZnTe - CdZnTe .…Sensitive in near IRSensitive in near IR
EESS ~ 0.1-1 mJ/cm ~ 0.1-1 mJ/cm22, , ~ 1 %, ~ 1 %, ~ 0.5 cm~ 0.5 cm-1-1
Photorefractive crystalsPhotorefractive crystals
10
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
Developed by CSL : 1993-1998Developed by CSL : 1993-1998
Cw Holographic CameraCw Holographic Camera
– Optical head : L=25 cm, diam=8 cmOptical head : L=25 cm, diam=8 cm
1 kg1 kg
– Laser : DPSS, VERDI 5WLaser : DPSS, VERDI 5W
– Laser light brought by optical fiberLaser light brought by optical fiber
– Specialty fiber developedSpecialty fiber developed
(5 m, Transmission 80%, 5W injected)(5 m, Transmission 80%, 5W injected)
– Mobile rack includingMobile rack including• laser + power supplylaser + power supply
• camera, piezo,.. electronic controlscamera, piezo,.. electronic controls
11
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
Applications : static measurementsApplications : static measurements– NDT (defect detection) : impacts-delamination in CFRPNDT (defect detection) : impacts-delamination in CFRP
Interferogram obtained after Interferogram obtained after thermal stimulation (40X55 thermal stimulation (40X55 cmcm22))
Calculated phase imageCalculated phase image Unwrapped image with vertical Unwrapped image with vertical differentiationdifferentiation
Cw Holographic CameraCw Holographic Camera
– NDT (defect detection) : lack of soldering in flat cables (NDT (defect detection) : lack of soldering in flat cables (10 x 5 cm10 x 5 cm22))
12
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
a
aluminium plate(back side)piezosheetspoint where the force is appliedclamping points of the plate
– Displacement metrology :Displacement metrology :• calibration of piezoelectric sheets (40x25 cmcalibration of piezoelectric sheets (40x25 cm22))
• sensor-actuators for smart structure controlsensor-actuators for smart structure control
• High fringe densityHigh fringe density
Cw Holographic CameraCw Holographic Camera
13
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
Cw Holographic CameraCw Holographic Camera– Displacement metrology :Displacement metrology :
• Determination of CTE of carbon fiber rods or assembliesDetermination of CTE of carbon fiber rods or assemblies
• Observe top of object and baseplateObserve top of object and baseplate
• After After T : Measure difference of displacements betw.T : Measure difference of displacements betw.– top of object : piston effecttop of object : piston effect
– baseplate : piston effectbaseplate : piston effect
a
samplebaseradiator
holographiccameraoptical fiber
object illuminationbeamwindow
14
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
Applications : Stroboscopic Real-TimeApplications : Stroboscopic Real-Time
– Acousto-optic shutter synchronizedAcousto-optic shutter synchronized
with sinusoidal excitationwith sinusoidal excitation
– Open at maximum object displacementOpen at maximum object displacement
– Displacement btw. average & maximum positionsDisplacement btw. average & maximum positions
– Duty cycle : 0.15 - 0.2Duty cycle : 0.15 - 0.2
– Compromise between fringe contrast - image intensityCompromise between fringe contrast - image intensity
Cw Holographic CameraCw Holographic Camera
a
t0-T+Tholographicrecordingstroboscopicreadout
a
tstroboscopic readout
StroboscopicshutterObjectdisplacementHologr.RecordingVisualisationFrequency scan
a
tstroboscopic readout
StroboscopicshutterHologr.RecordingImagecapturePhase-shiftingObjectdisplacement Acquisition
15
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
ApplicationsApplications– Academic demonstration : Metallic plate excited with loudspeakerAcademic demonstration : Metallic plate excited with loudspeaker
(M. Georges, Ph. Lemaire, Optics Comm. 98)(M. Georges, Ph. Lemaire, Optics Comm. 98)
– Recent tests (by Optrion) : Compressor blades for new aircraft engineRecent tests (by Optrion) : Compressor blades for new aircraft engine• Certification predicted resonance frequencies and mode shapesCertification predicted resonance frequencies and mode shapes
• Several modes found were not predictedSeveral modes found were not predicted
Stroboscopic systemStroboscopic system
16
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
17
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
PositivePositive– High quality resultsHigh quality results
– Convenient for mode shape visualizationConvenient for mode shape visualization
– Convenient for comparison with predicted frequencies / mode Convenient for comparison with predicted frequencies / mode shapesshapes
– Userfriendly device, indefinitely reusableUserfriendly device, indefinitely reusable
Limits :Limits :– Displacements : from 15-20 nm to 30 micronsDisplacements : from 15-20 nm to 30 microns
– StroboscopeStroboscope• loss of light (80 % with 0.2 duty cycle)loss of light (80 % with 0.2 duty cycle)
• small objects (25x25 cmsmall objects (25x25 cm22) with 500 mW laser) with 500 mW laser
18
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
MotivationsMotivations– Luminous Energy concentrated over a few nanosecondsLuminous Energy concentrated over a few nanoseconds
• One can deal with perturbed environmentOne can deal with perturbed environment
• No more illumination constraints at the readout stepNo more illumination constraints at the readout step
(like in the case of stroboscopic readout with cw laser)(like in the case of stroboscopic readout with cw laser)
– 2 pulses with variable delay2 pulses with variable delay• High vibration amplitudesHigh vibration amplitudes
• Fast transient eventsFast transient events
Pulsed systemPulsed system
19
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
First worksFirst works– LCFIO (group of G. Roosen-G. Pauliat)LCFIO (group of G. Roosen-G. Pauliat)
• Labrunie Labrunie et alet al., Opt. Lett. 20 (1995)., Opt. Lett. 20 (1995)
• Labrunie Labrunie et alet al., PR ’95., PR ’95
• Labrunie Labrunie et alet al., Opt. Comm. 140 (1997)., Opt. Comm. 140 (1997)
PR crystal weak sensitivityPR crystal weak sensitivity at 694 nmat 694 nm
New crystal BGO:CuNew crystal BGO:Cu
BSO - BGOBSO - BGO 488 - 514 - 532 nm488 - 514 - 532 nm
(J-C. Launay, ICMCB Bordeaux)(J-C. Launay, ICMCB Bordeaux)
– Ruby LaserRuby Laser
– Quality of results (vibration mode of turbine blade) was average, Quality of results (vibration mode of turbine blade) was average, tough acceptabletough acceptable
Pulsed systemPulsed system
20
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
New developments since 1998 (CSL and LCFIO)New developments since 1998 (CSL and LCFIO)
– Use Q-switch YAG laser (COHERENT Infinity)Use Q-switch YAG laser (COHERENT Infinity)
frequency doubled : 532 nm (adapted to sillenite crystals)frequency doubled : 532 nm (adapted to sillenite crystals)
pulses : 3 nspulses : 3 ns
energies : 0 to 400 mJ/pulseenergies : 0 to 400 mJ/pulse
repetition rate : 0,1 to 30 Hzrepetition rate : 0,1 to 30 Hz
– Additional equipment for energy balance between pulsesAdditional equipment for energy balance between pulses
– Application in vibration measurementApplication in vibration measurement
Pulsed systemPulsed system
21
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
Pulsed systemPulsed system
– Pulse 1 : all energy used for the recording Pulse 1 : all energy used for the recording
– Pulse 2 : readoutPulse 2 : readout• decrease Edecrease Eobjobj to avoid CCD blooming to avoid CCD blooming
• decrease Edecrease Erefref to not erase the hologram to not erase the hologram
a
Pockels 1
a
Pockels 3
aa
delaylineM4M5
M1M2M3
PRcrystalO1O2PBC3O3O3’Cam 1Cam 2PBC2HWP1
DLCLDLM6 object
a
CSP2Pockels 2
a
lighttrap– Phase Phase measurement : measurement :
• Cam 1 : I = ICam 1 : I = I0101 (1+m sin (1+m sin ))
• Cam 2 : I = ICam 2 : I = I0202 (1+m cos (1+m cos ))
22
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
VibrationsVibrations 4 pulses technique4 pulses technique
Rt = A f cos Φ f + ωt
D1 = A f cos Φ f+ ωτ + ωt0 – cos Φ f+ ωt0
D2 = A f cos Φ f+ ωτ + ωt0 + π
2– cos Φ f+ ωτ + π
2
a
0 t
A f=D1
2 + D22
2 1 – cos ωτ
a
W1t0
a
R1
a
W2T/4
a
R2
23
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
In practiceIn practice– Laser :Laser : 1 pulse1 pulse
30 Hz max30 Hz max
– High frequencies : Use several cycles at a given frequency High frequencies : Use several cycles at a given frequency
Results :Results :– Object : Aluminium plate clamped on one edgeObject : Aluminium plate clamped on one edge
– Excitation : LoudspeakerExcitation : Loudspeaker
Frequency range : 20-380 HzFrequency range : 20-380 Hz Interferograms serie exampleInterferograms serie example
359-365 Hz359-365 Hz
24
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
Amplitude of the frequency response in 2 pointsAmplitude of the frequency response in 2 points
0
1
2
3
4
5
0 50 100 150 200 250 300 350 400
( )fréquence Hz
0
0,05
0,1
0,15
0,2
0,25
0,3
0,35
0,4
0 50 100 150 200 250 300 350 400
( )fréquence Hz
25
Centre Spatial de LiègeUniversité de Liège
© Centre Spatial de Liège 2002
Conclusion - Future prospectsConclusion - Future prospects Present : PHIFE « Pulsed Holographic Interferometer for Present : PHIFE « Pulsed Holographic Interferometer for
analysis of Fast Events »analysis of Fast Events » Development of holographic headsDevelopment of holographic heads
– Improvement of existing ones (new crystal configuration/properties)Improvement of existing ones (new crystal configuration/properties)
– different wavelengthsdifferent wavelengths
Development of double-pulse laser (INNOLAS)Development of double-pulse laser (INNOLAS)– YAG Q-switchedYAG Q-switched
– 25 Hz, 8 nsec, 800 mJ (1064 nm)25 Hz, 8 nsec, 800 mJ (1064 nm)
– delay : up to 0.1 delay : up to 0.1 ss
Applications in industrial cases (vibrations, transient events, Applications in industrial cases (vibrations, transient events,
aerodynamics)aerodynamics)