CENTRIA 07 42 13 Metal Wall Panels Page 1 of 18
CENTRIA IW SeriesTM Metal Wall Panels
CENTRIA IW SERIESTM Concealed Fastener Metal Wall Panels are a versatile design choice for both new and retrofit projects. Panels are available with hot-dip galvanized, Galvalume®, or Galvalume Plus®
coated steel and aluminum and stainless steel substrates. They are manufactured with a variety of
profiles and surface treatments; and are available in over 60 standard colors plus custom colors.
CENTRIA IW SeriesTM Metal Wall Panels coated with CENTRIA's own Fluorofinish® Kynar 500® or Hylar
5000®-based fluoropolymer or Versacor® corrosion- and abrasion- resistant finishes will last for decades. Highly UV resistant and durable in the face of chemical and air borne pollution, salt spray and wind-
driven sand, CENTRIA coatings set the standard for the industry. IW Series Metal Wall Panels are
available in over 60 standard colors and additional custom colors.
CENTRIA Metal Wall Panels are used in both horizontal and vertical configurations, and are available with
a factory-installed sealant in the side joint to help minimize water intrusion. They may serve as the exterior cladding components of an overall wall assembly that includes CENTRIA MetalWrap® insulated
composite metal backup panels that provides an insulated substrate complete with moisture, air, and vapor control.
CENTRIA Microline extrusions offer the designer an integrated trim system that ensure aesthetic control
over the profile of visual components of the wall assembly. CENTRIA MicroSeam® mitered trimless corners accentuate horizontal lines.
Consult your local CENTRIA architectural representative for design assistance. Contact CENTRIA, Pittsburgh, PA, (800)759-7474, Email: [email protected], www.centria.com for a list of offices.
CENTRIA is a world leader in the manufacture of metal building products and systems for nonresidential
walls and roofs. CENTRIA is also a world-class coil coater, coating a wide range of products for customers in numerous industries.
CENTRIA products appear in the following MasterFormat sections: ● Section 07 41 13 – Metal Roof Panels (SRS3)
● Section 07 41 16 – Insulated Core Metal Roof Panels (Versapanel) ● Section 07 42 13 – Metal Wall Panels (Cascade Metal Panel System, Intercept V-Trac, Intercept
Entyre, Paradigm EXP, Concept Series, IW Series, Exposed Fastener Panels)
● Section 07 42 16 – Insulated-Core Metal Wall Panels (Formawall Dimension Series, Formawall Graphix Series, Versawall, Versapanel, Foamwall, Versashield MW)
● Section 07 42 17 – Insulated Composite Backup Panel (MetalWrap) ● Section 07 42 43 – Composite Wall Panels (FormaBond)
Specifier: This document is organized according to CSI MasterFormat™. Edit section number and title as
appropriate to the Project. Bold items require specifier selection. Convert bold to plain text and delete notes before publishing.
IW SeriesTM and MetalWrapTM are trademarks of CENTRIA, Inc.
Fluorofinish® and Versacor® are a registered trademarks of CENTRIA, Inc.
CENTRIA 07 42 13 Metal Wall Panels Page 2 of 18
Galvalume® and Galvalume Plus® are registered trademarks of BIEC International, Inc. Kynar 500® is a registered trademark of Arkema, Inc.
Hylar 5000® is a registered trademark of Solvay S.A. MasterFormat™ is a trademark of the Construction Specifications Institute.
This document is Copyright© 2014 CENTRIA. All rights reserved.
CENTRIA 07 42 13 Metal Wall Panels Page 3 of 18
SECTION 07 42 13.02
METAL WALL PANELS
PART 1 - GENERAL
1.1 SECTION INCLUDES
A. Concealed fastener metal wall panels [, and liner panels] as part of the assembly described in
Section 2.1.
1.2 RELATED REQUIREMENTS
Specifier: If retaining Related Requirements Article, edit list below to correspond to Project.
A. Division 01 Section "Sustainable Design Requirements" for related LEED general requirements.
B. Division 07 Section "Sheet Metal Flashing and Trim" for sheet metal copings, flashings, reglets
and roof drainage items.
C. Division 07 Section "Joint Sealants" for field-applied joint sealants.
1.3 REFERENCES
Specifier: If retaining References Article, edit list below to correspond to Project.
A. American Architectural Manufacturer's Association (AAMA):
1. AAMA 501.1 - Test Method for Water Penetration of Windows, Curtain Walls and Doors Using Dynamic Pressure.
2. AAMA 620 - Voluntary Specification for High Performance Organic Coatings on Coil
Coated Architectural Aluminum Substrates. 3. AAMA 621 - Voluntary Specification for High Performance Organic Coatings on Coil
Coated Architectural Hot Dipped Galvanized (HDG) and Zinc-Aluminum Coated Steel Substrates.
B. American Society of Civil Engineers (ASCE):
1. ASCE 7 - Minimum Design Loads for Buildings and Other Structures.
C. ASTM International (ASTM):
1. ASTM A 653/A 653M - Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process.
2. ASTM A 666 - Standard Specification for Annealed or Cold-Worked Austenitic Stainless Steel Sheet, Strip, Plate, and Flat Bar.
3. ASTM A 755/A 755M - Specification for Steel Sheet, Metallic Coated by the Hot-Dip
Process and Prepainted by the Coil-Coating Process for Exterior Exposed Building Products.
4. ASTM A 792/A 792 M - Standard Specification for Steel Sheet, 55 % Aluminum-Zinc Alloy-Coated by the Hot-Dip Process.
CENTRIA 07 42 13 Metal Wall Panels Page 4 of 18
5. ASTM B 209 - Specification for Aluminum and Aluminum Alloy Sheet and Plate.
6. ASTM C 754 - Specification for Installation of Steel Framing Members to Receive Screw Attached Gypsum Panel Products.
7. ASTM C 920 - Specification for Elastomeric Joint Sealants. 8. ASTM C 1007 - Standard Specification for Installation of Load Bearing (Transverse and
Axial) Steel Studs and Related Accessories.
9. ASTM E 72 - Standard Test Methods of Conducting Strength Tests of Panels for Building Construction.
10. ASTM E 283 - Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors under Specified Pressure Differences across the
Specimen. 11. ASTM E 331 - Test Method for Water Penetration of Exterior Windows, Curtain Walls, and
Doors by Uniform Static Air Pressure Difference.
D. Sheet Metal and Air Conditioning Contractors National Association, Inc. (SMACNA):
1. Architectural Sheet Metal Manual.
1.4 PERFORMANCE REQUIREMENTS
Specifier: Add requirements to this Article if Project requirements include delegated design by
Contractor.
A. General: Provide metal wall panel assemblies meeting performance requirements as determined by application of specified tests by a qualified testing agency on manufacturer's
standard assemblies.
B. Air Infiltration: When installed over Insulated Composite Backup Panels or Metal Liner Panels,
maximum 0.06 cfm/sq. ft. (0.3 L/s per sq. m) per ASTM E 283 at a static-air-pressure difference of 1.57 lb./sq. ft. (75 Pa), using minimum 10-by-10 foot (3050-by-3050 mm) test panel that
includes side joints.
C. Water Penetration, Static Pressure: When installed over Insulated Composite Backup Panels or Metal Liner Panels, no uncontrolled water penetration per ASTM E 331 at a minimum static
differential pressure of 6.24 lb./sq. ft. (299 Pa), using minimum 10-by-10 foot (3050-by-3050 mm) test panel that includes side joints.
Specifier: CENTRIA recommends minimum 22 gage metal wall panels for enhanced structural performance and optimum aesthetic appearance. CENTRIA IW Series IW-13A, IW-21A, and liner panels
are also available in 24 gage. IW Series 13A is not available in 18 gage.
D. Structural Performance: Provide metal wall panel assemblies capable of withstanding the effects of indicated loads and stresses within limits and under conditions indicated for
disengagement, per ASTM E 72.
Specifier: Consult structural engineer and edit below as required by local codes. Insert structural data
below if not indicated on drawings.
1. Wind Loads: Determine loads based on uniform pressure, importance factor, exposure category, and basic wind speed indicated on drawings.
2. Limits of Deflection: Metal wall panel assembly shall withstand scheduled wind pressure with the following allowable deflection:
CENTRIA 07 42 13 Metal Wall Panels Page 5 of 18
a. Maximum allowable deflection limited to L/180 deflection of panel perimeter
normal to plane of wall with no evidence of failure.
3. Secondary Metal Framing: Design secondary metal framing for metal wall panel assembly
according to AISI's "Standard for Cold-Formed Steel Framing - General Provisions."
4. Side Joint Disengagement: Panels must be designed and tested under Negative load per
ASTM E 72.
Specifier: Delete paragraph if not required by authority having jurisdiction.
E. Florida State Building Code Compliance: Provide wall panels that comply with the requirements
for installation under Florida State Building Code aside of the High Velocity Hurricane Zone.
Specifier: For horizontal applications, and other applications where thermal movement is an issue, retain
the requirements below.
F. Thermal Movements: Allow for thermal movements from variations in both ambient and
internal temperatures. Accommodate movement of support structure caused by thermal expansion and contraction.
Specifier: Retain paragraph below if foam plastic insulation is included within the wall system.
G. Wall systems that incorporate foam plastic insulation must be tested by the foam plastic
supplier in accordance with NFPA-285.
1.5 QUALITY ASSURANCE
A. Manufacturer/Source: Provide metal wall panel and panel accessories from a single
manufacturer.
Specifier: Retain paragraph below if Owner allows substitutions but requires strict control over qualifying
of substitutions.
B. Manufacturer Qualifications: Approved manufacturer listed in this Section with minimum 10
years experience in manufacture of similar products in successful use in similar applications.
1. Approval of Comparable Products: Submit the following in accordance with project substitution requirements, within time allowed for substitution review:
a. Product data, including certified independent test data indicating compliance with requirements.
b. Sample submittal from similar project.
c. Project references: Minimum of 5 installations not less than 5 years old, with Owner and Architect contact information.
d. Sample warranty.
2. Substitutions following award of contract are not allowed except as stipulated in Division
01 General Requirements.
3. Approved manufacturers must meet separate requirements of Submittals Article.
CENTRIA 07 42 13 Metal Wall Panels Page 6 of 18
C. Wall Systems Installer Qualifications: Experienced Installer with minimum of 5 years
experience with successfully completed projects of a similar nature and scope.
1.6 ADMINISTRATIVE REQUIREMENTS
A. Preinstallation Meeting: Conduct preinstallation meeting at site attended by Owner, Architect, manufacturer's representative, and other trade contractors.
1. Coordinate building framing in relation to metal wall panel assembly.
2. Coordinate installation of building air and water barrier behind metal wall panel assembly.
3. Coordinate window, door and louver, and other openings and penetrations of metal wall panel assembly.
1.7 ACTION SUBMITTALS
A. Product Data: Manufacturer’s data sheets, for specified products.
1. Include data indicating compliance with performance requirements, including load span
tables tested for side joint disengagement under negative loads per ASTM E 72.
B. Shop Drawings: Provide shop drawings prepared by manufacturer or manufacturer's authorized
Installer. Include full elevations showing openings and penetrations. Include details of each condition of installation and attachment. Provide details at a minimum scale 1-1/2-inch per foot
(1:8) of all required trim and extrusions needed for a complete installation.
1. Indicate points of supporting structure that must coordinate with metal wall panel assembly installation.
C. Samples for Initial Selection: For each product specified. Provide representative color charts of manufacturer's full range of colors.
D. Samples for Verification: Provide 12-inch (300 mm) section of panel(s) showing finishes. Provide 12-inch (300 mm) long pieces of trim pieces and other exposed components.
1.8 INFORMATIONAL SUBMITTALS
A. Product Test Reports: Indicating compliance of products with requirements, from a qualified independent testing agency.
Specifier: Retain paragraphs below when Project requirements include compliance with Federal Buy
American provisions. CENTRIA Metal Wall Panels comply with requirement.
B. Buy American Act Certification: Submit documentation certifying that products comply with
provisions of the Buy American Act 41 U.S.C 10a – 10d.
C. Qualification Information: For Installer firm.
D. Manufacturer's warranty: Submit sample warranty.
1.9 CLOSEOUT SUBMITTALS
A. Maintenance data.
CENTRIA 07 42 13 Metal Wall Panels Page 7 of 18
1.10 DELIVERY, STORAGE, AND HANDLING
A. Protect metal wall panel products during shipping, handling, and storage to prevent staining, denting, deterioration of components or other damage.
1. Deliver, unload, store, and erect metal wall panel products and accessory items without misshaping panels or exposing panels to surface damage from weather or construction
operations.
1.11 WARRANTY
Specifier: Warranty terms below are available from CENTRIA. Verify that other allowable manufacturers
furnish warranty meeting requirements.
A. Special Manufacturer’s Warranty: On manufacturer’s standard form, in which manufacturer
agrees to repair or replace components of metal wall panel assemblies that fail in materials and workmanship within [two] years from date of Substantial Completion.
Specifier: Consult CENTRIA representative to verify available finish warranty.
B. Special Panel Finish Warranty: On manufacturer’s standard form, in which manufacturer agrees to repair or replace metal wall panels that display evidence of deterioration of finish within [20]
years from the date of substantial completion.
PART 2 - PRODUCTS
2.1 SYSTEM DESCRIPTION
Specifier: Retain one or more of six wall system descriptions below that correspond to Project Requirements; edit as required.
System below describes installation of metal wall panels over CENTRIA MetalWrap backup system.
A. Metal Wall Panels over Insulated-Composite Backup Panel Wall System: Single-skin
concealed fastener metal wall panels serving as the exterior rainscreen cladding component of a metal wall panel system that includes insulated composite metal wall backup panels specified
in Division 07 Section "Insulated-Composite Backup Panel System." Metal wall backup panels
provide thermal, air, water, and water vapor control. Metal wall panel installation specified in this Section includes secondary metal subgirt framing for panel attachment.
B. Metal Wall Panels and Metal Liner Panel Wall System: Single-skin concealed fastener metal wall panels applied as the exterior cladding over wall framing specified in [Division 05
Section "Cold-Formed Metal Framing" ] [Division 13 Section "Metal Building Systems" ]with
board insulation and metal liner panels. Metal wall panel installation specified in this Section includes secondary metal subgirt framing for panel attachment and an interior sealed-joint
metal liner panel that provides air and water vapor control.
1. Water-resistive barrier is required for Horizontal Liner applications and is under Division
07 Section "Weather Barriers."
C. Metal Wall Panels over Multi-Component Framed Wall System: Single-skin concealed fastener metal wall panels applied as exterior rainscreen cladding over wall framing specified in
CENTRIA 07 42 13 Metal Wall Panels Page 8 of 18
Division 05 Section "Cold-Formed Metal Framing" with exterior sheathing specified in Division
06 Section "Sheathing", an applied membrane that provides air, moisture, and water vapor control specified in Division 07 Section "Air Barriers", and insulation within the framing specified
in Division 07 Section "Thermal Insulation." Metal wall panel installation specified in this Section includes secondary metal subgirt framing for panel attachment.
Specifier: Retain subparagraph below. Product is not by CENTRIA.
1. Air, moisture, and water vapor control membrane is provided under Division 07 Section
"Air Barriers."
D. Metal Wall Panels over Outside-Insulated Framed Wall System: Single-skin concealed
fastener metal wall panels applied as exterior rainscreen cladding over wall framing specified in Division 05 Section "Cold-Formed Metal Framing" with exterior sheathing specified in Division
06 Section "Sheathing", an applied membrane that provides air, moisture, and water vapor
control specified in Division 07 Section "Air Barriers", and insulation [within the framing and] applied outboard of the sheathing specified in Division 07 Section "Thermal Insulation." Metal
wall panel installation specified in this Section includes secondary metal subgirt framing for panel attachment.
Specifier: Retain subparagraph below for horizontal panels. Product is not by CENTRIA.
1. Air, moisture, and water vapor control membrane is provided under Division 07 Section
"Air Barriers."
E. Metal Wall Panels over Uninsulated Framed [Screen] Wall System : Single-skin
concealed fastener metal wall panels applied as exterior barrier cladding over wall framing specified in [Division 05 Section “Cold-Formed Metal Framing”] [Division 13 Section “Metal
Building Systems”] [and water-resistive barrier specified in Division 7 “Weather Barriers]. Metal
wall panel installation specified in this Section includes secondary metal subgirt framing for panel attachment.
F. Metal Wall Panels over Masonry Wall System: Single-skin concealed fastener metal wall panels applied as exterior rainscreen cladding over a masonry wall [and rigid board insulation]
specified in Division 04 Section "Unit Masonry" and an applied membrane that provides air,
moisture, and water vapor control specified in Division 07 Section "Air Barriers." Metal wall panel installation specified in this Section includes secondary metal subgirt framing for panel
attachment.
Specifier: Retain subparagraph below for horizontal panels. Product is not by CENTRIA.
1. Air, moisture, and water vapor control membrane is provided under Division 07 Section "Air Barriers."
2.2 MANUFACTURERS
A. Basis of Design: CENTRIA, IW Series Metal Wall Panels. Provide basis of design product
[, or comparable product approved by Architect prior to bid].
CENTRIA 07 42 13 Metal Wall Panels Page 9 of 18
1. CENTRIA Architectural Systems; Moon Township, PA 15108-2944. Tel: (800)759-7474.
Tel: (412)299-8000. Fax: (412)299-8317. Email: [email protected]. Web: www.CENTRIA.com.
2.3 PANEL MATERIALS
Specifier: Select metal wall panel face material from three paragraphs below. Aluminum-zinc alloy-coated steel sheet, Galvalume, Galvalume Plus with a thin, clear acrylic topcoat, is also available and is
recommended for uniform weathering when specified without an applied paint finish.
A. Metallic-Coated Steel Face Sheet: Coil-coated, ASTM A 755/A 755M.
1. Zinc-Coated (Galvanized) Steel Sheet: ASTM A 653/A 653M, G90 (Class Z275), structural steel quality.
2. Aluminum-zinc alloy-coated (Galvalume) Steel Sheet: ASTM A 792/A 792 M, Class AZ50 Grade 50 (Class AZM150, Grade 275), structural steel quality.
Specifier: Select required metal face sheet thickness from options below. 0.024 inch/24 gage (0.60 mm) thickness is available for IW-13A and IW-21A profiles only; CENTRIA recommends minimum 0.030
inch/22 gage (0.76 mm) thickness. 0.047 inch/18 gage (1.19 mm) is available in smooth surface only.
3. Face Sheet: Minimum [0.024 inch/24 gage (0.60 mm)] [0.030 inch/22 gage (0.76 mm)] [0.036 inch/20 gage (0.91 mm)] [0.047 inch/18 gage (1.19 mm)] nominal uncoated
thickness.
4. Surface: [Smooth] [Non-Directional Embossed].
B. Aluminum Face Sheet: Smooth surface coil-coated, ASTM B209, 3003-H14 or 5052-H32
alloy.
Specifier: Select required metal face sheet thickness from options below.
1. Face Sheet: [0.040 inch (1.0 mm)] [0.050 inch (1.27 mm)] nominal thickness. 2. Surface: [Smooth] [Non-Directional Embossed].
Specifier: Retain and edit subparagraph below for projects that include requirements for use of recycled
content in products. Verify proportion of recycled content with manufacturer.
3. Aluminum Products Recycled Content: Average of postconsumer recycled content plus
one-half of preconsumer recycled content not less than 50 percent.
C. Stainless-Steel Face Sheet: ASTM A 666, architectural grade alloy type as indicated.
1. Face Sheet: [0.030 inch/22 gage (0.76 mm)] [0.036 inch/20 gage (0.91 mm)] nominal
thickness.
Specifier: Type 316 alloy is recommended for marine and other corrosive environments.
2. Finish: [Type 304] [Type 316], #4 Brushed.
CENTRIA 07 42 13 Metal Wall Panels Page 10 of 18
2.4 CONCEALED FASTENER METAL WALL PANELS
Specifier: All CENTRIA IW Series concealed fastener metal wall panels are suitable for horizontal and vertical installation; and panels are manufactured with a common lock joint design that permits the integration of multiple profiles in one system. Standard lengths are 5 to 30 feet; custom length panels
are available on special order.
Specify optional factory-applied sealant in vertical panel side laps when added water resistance is
required. CENTRIA recommends a complete water-resistant barrier behind horizontal panels.
If using more than one metal wall panel, retain the drawing designation below for each panel. If metal types, thicknesses, surfaces, or finish systems differ, add notes below to indicate the metal type,
thickness, surface, and finish for each panel on project.
A. Metal Wall Panels, General: Factory-formed, concealed fastener panels with interconnecting side joints, fastened to supports with concealed fasteners, with factory-applied sealant in side
laps when required to meet performance requirements.
B. Horizontal Joints: Horizontal Joints with drip edge and sloped drain shelf to provide positive water shed away from Panel Joinery.
Specifier: CENTRIA IW Series metal wall panels are available in standard panel lengths from 5 foot (1524
mm) to 30 foot (9144 mm). Custom length panels are available on special order.
C. Flush-joint profile with raised flat pan MWP#___:
1. Basis of Design Product: CENTRIA, IW-10A. 2. Panel Coverage: 12 inches (305 mm).
3. Panel Height: 1.50 inches (38 mm).
D. Flush-joint profile with raised flat pan and two stiffener beads MWP#___:
1. Basis of Design Product: CENTRIA, IW-11A. 2. Panel Coverage: 12 inches (305 mm).
3. Panel Height: 1.50 inches (38 mm).
4. Stiffening Beads: Two.
E. Flush-joint profile with raised flat pan partially striated MWP#___:
1. Basis of Design Product: CENTRIA, IW-12A. 2. Panel Coverage: 12 inches (305 mm).
3. Panel Height: 1.50 inches (38 mm).
F. Flush-joint profile with raised flat pan striated MWP#___:
1. Basis of Design Product: CENTRIA, IW-13A.
2. Panel Coverage: 12 inches (305 mm). 3. Panel Height: 1.50 inches (38 mm).
G. Flush-joint profile with raised flat pan with single centered stiffener bead MWP#___:
1. Basis of Design Product: CENTRIA, IW-14A. 2. Panel Coverage: 12 inches (305 mm).
CENTRIA 07 42 13 Metal Wall Panels Page 11 of 18
3. Panel Height: 1.50 inches (38 mm).
H. Flush-joint profile with raised flat pan and three stiffener beads MWP#___:
1. Basis of Design Product: CENTRIA, IW-15A.
2. Panel Coverage: 12 inches (305 mm). 3. Panel Height: 1.50 inches (38 mm).
I. Flush-joint profile with half-raised and half flush pans MWP#___:
1. Basis of Design Product: CENTRIA, IW-20A. 2. Panel Coverage: 12 inches (305 mm).
3. Panel Height: 1.50 inches (38 mm).
J. Flush-joint profile with half-raised and half flush pans with center stiffener beads MWP#___:
1. Basis of Design Product: CENTRIA, IW-21A. 2. Panel Coverage: 12 inches (305 mm).
3. Panel Height: 1.50 inches (38 mm).
K. Two inch (51 mm) reveal-joint profile with raised flat pan MWP#___:
1. Basis of Design Product: CENTRIA, IW-30A.
2. Panel Coverage: 12 inches (305 mm). 3. Panel Height: 1.50 inches (38 mm).
L. Two inch (51 mm) reveal-joint profile with raised flat pan and two stiffener beads MWP#___:
1. Basis of Design Product: CENTRIA, IW-31A. 2. Panel Coverage: 12 inches (305 mm).
3. Panel Height: 1.50 inches (38 mm).
M. One inch (25 mm) reveal-joint profile with raised flat pan MWP#___:
1. Basis of Design Product: CENTRIA, IW-40A. 2. Panel Coverage: 12 inches (305 mm).
3. Panel Height: 1.50 inches (38 mm).
N. One inch (25 mm) reveal-joint profile with raised flat pan and two stiffener beads MWP#___:
1. Basis of Design Product: CENTRIA, IW-41A.
2. Panel Coverage: 12 inches (305 mm). 3. Panel Depth: 1.50 inches (38 mm).
Specifier: Select metallic-coated steel face sheet or aluminum face sheet finish system from options below. AAMA 620 is aluminum sheet finish standard; AAMA 621 is metallic-coated steel sheet finish
standard. Delete all finish options if specifying stainless steel face sheet.
O. Exposed Coil-Coated Finish System:
1. Fluoropolymer Two-Coat System: 0.2 mil primer with 0.8 mil 70 percent PVDF
fluoropolymer color coat, AAMA [620] [621].
CENTRIA 07 42 13 Metal Wall Panels Page 12 of 18
a. Basis of Design: CENTRIA Fluorofinish.
2. Fluoropolymer Two-Coat System: 0.8 mil primer with 0.8 mil 70 percent PVDF fluoropolymer color coat, AAMA [620] [621].
a. Basis of Design: CENTRIA Duragard.
3. Fluoropolymer Three-Coat System: 0.8 mil primer with 0.8 mil 70 percent PVDF
fluoropolymer color coat, and a 0.8 mil 70 percent PVDF fluoropolymer clear coat,
AAMA [620] [621].
a. Basis of Design: CENTRIA Duragard Plus.
4. Fluoropolymer Two-Coat Mica System: 0.25 mil primer with 0.8 mil 70 percent PVDF fluoropolymer color coat providing a pearlescent appearance, AAMA [620] [621].
a. Basis of Design: CENTRIA Sundance Mica.
5. Fluoropolymer Three Coat Metallic System : 0.2 mil primer, with 0.8 mil 70 percent PVDF
fluoropolymer color coat with metal flakes, and a 0.5 mil 70 percent PVDF fluoropolymer
clear coat, AAMA [620] [621].
a. Basis of Design: CENTRIA Sundance AM.
Specifier: The three CENTRIA Versacor systems below are recommended for corrosive and abusive environments. Select system and one of three options for panel interior finish based on exposure and
environmental conditions. Consult CENTRIA representative for recommended finish system.
6. Fluoropolymer Two-Coat Corrosion and Abrasion Resistant System: 2.0 mil barrier coat primer with 0.8 mil 70 percent PVDF fluoropolymer color coat.
a. Basis of Design: CENTRIA Versacor Elite PF.
7. Fluoropolymer Two-Coat Corrosion and Abrasion Resistant System: 2.0 mil barrier coat
primer with 0.8 mil 70 percent PVDF fluoropolymer color coat that includes mica flakes that provides a pearlescent appearance.
a. Basis of Design: CENTRIA Versacor Elite MX.
8. Fluoropolymer Two-Coat Corrosion and Abrasion Resistant System: 2.0 mil barrier coat primer with 0.8 mil 70 percent PVDF fluoropolymer color coat that includes aluminum
metal flakes, with a 0.5 mil PVDF clear topcoat.
a. Basis of Design: CENTRIA Versacor Elite AM.
9. Fluoropolymer Three Coat System: 0.2 mil primer with a 0.5 mil polyester base coat and
a 0.8 mil nominal PVDF fluoropolymer top coat providing an iridescent finish.
a. Basis of Design: CENTRIA KolorShift.
10. Fluoropolymer Three Coat System: 0.65 mil color base coat and Primer with a 0.05 mil PVDF ink coat and a 0.45 nominal PVDF fluoropolymer clear coat.
CENTRIA 07 42 13 Metal Wall Panels Page 13 of 18
a. Basis of Design: CENTRIA Allusion.
11. Fluoropolymer Two Coat System: 0.2 mil primer with a 0.8 mil PVDF matte, low gloss color coat with fine aggregate finish.
a. Basis of Design: CENTRIA Allura.
P. Color:
Specifier: Retain one or both subparagraphs below has required for Project.
1. Exterior Surface: [As indicated] [As selected by Architect from manufacturer's standard colors] [Match Architect's custom color].
2. Interior Surface: [Manufacturer's standard primer color] [As indicated] [As selected by Architect from manufacturer's standard colors] [Match Architect's custom color].
2.5 LINER PANELS
Specifier: Retain this Article if liner panel is required on interior of framing assembly. Standard lengths are 5 to 30 feet; custom length panels are available on special order. Deeper liner panels may be used in
conjunction with thicker insulation.
A. Metal Liner Panels, General: Factory-formed, with interconnecting side joints, fastened to supports with approved fasteners.
1. [Zinc-Coated (Galvanized) steel sheet] [Aluminum-zinc alloy-coated (Galvalume) steel
sheet]. 2. Face Sheet: Minimum [0.024 inch/24 gage (0.60 mm)] [0.030 inch/22 gage (0.76 mm)]
[0.036 inch/20 gage (0.91 mm)] [0.047 inch/18 gage (1.19 mm)] nominal uncoated thickness.
3. Panel Sheet: [Solid] [Perforated, with 10 percent free area]. 4. Surface: [Smooth] [Non-directional embossed].
B. Metal liner panel MLP#___:
1. Basis of Design Product: CENTRIA, L2. 2. Panel Coverage: 24 inches (610 mm).
3. Panel Depth: 1.375 inches (35 mm). 4. Stiffening Beads: Two.
C. Metal liner panel MLP#___:
1. Basis of Design Product: CENTRIA, L2-2. 2. Panel Coverage: 24 inches (610 mm).
3. Panel Depth: 2 inches (51 mm). 4. Stiffening Beads: Two.
D. Metal liner panel MLP#___:
1. Basis of Design Product: CENTRIA, L2-3. 2. Panel Coverage: 24 inches (610 mm).
3. Panel Depth: 3 inches (76 mm).
CENTRIA 07 42 13 Metal Wall Panels Page 14 of 18
4. Stiffening Beads: Two.
E. Exposed Coil-Coated Finish System:
1. Fluoropolymer Two-Coat System: 0.2 mil primer with 0.8 mil 70 percent PVDF
fluoropolymer color coat, AAMA 621.
a. Basis of Design: CENTRIA Fluorofinish.
2. Fluoropolymer Two-Coat System: 0.8 mil primer with 0.8 mil 70 percent PVDF
fluoropolymer color coat, AAMA 621.
a. Basis of Design: CENTRIA Duragard.
3. Fluoropolymer Three-Coat System: 0.8 mil primer with 0.8 mil 70 percent PVDF fluoropolymer color coat, and a 0.8 mil 70 percent PVDF fluoropolymer clear coat, AAMA
621.
a. Basis of Design: CENTRIA Duragard Plus.
4. Fluoropolymer Two-Coat Mica System: 0.25 mil primer with 0.8 mil 70 percent PVDF
fluoropolymer color coat providing a pearlescent appearance, AAMA 621.
a. Basis of Design: CENTRIA Sundance Mica.
5. Fluoropolymer Three-Coat Metallic System: 0.2 mil primer with 0.8 mil 70 percent PVDF fluoropolymer color coat containing metal flakes, and a 0.5 mil 70 percent PVDF
fluoropolymer clear coat, AAMA 621.
a. Basis of Design: CENTRIA Sundance AM.
Specifier: The six CENTRIA Versacor systems below are recommended for corrosive and abusive environments. Select system and one of six options for panel interior finish based on exposure and
environmental conditions. Consult CENTRIA representative for recommended finish system.
6. Fluoropolymer Two-Coat Corrosion and Abrasion Resistant System: 2.0 mil barrier coat primer with 0.8 mil 70 percent PVDF fluoropolymer color coat.
b. Basis of Design: CENTRIA Versacor Elite PF.
7. Fluoropolymer Two-Coat Corrosion and Abrasion Resistant System: 2.0 mil barrier coat primer with 0.8 mil 70 percent PVDF fluoropolymer color coat that includes mica flakes
that provides a pearlescent appearance.
b. Basis of Design: CENTRIA Versacor Elite MX.
8. Fluoropolymer Two-Coat Corrosion and Abrasion Resistant System: 2.0 mil barrier coat
primer with 0.8 mil 70 percent PVDF fluoropolymer color coat that includes aluminum metal flakes, with a 0.5 mil PVDF clear topcoat.
b. Basis of Design: CENTRIA Versacor Elite AM.
CENTRIA 07 42 13 Metal Wall Panels Page 15 of 18
9. Fluoropolymer Three Coat System: 0.2 mil primer with a 0.5 mil polyester base coat and
a 0.8 mil nominal PVDF fluoropolymer top coat providing an iridescent finish.
b. Basis of Design: CENTRIA KolorShift.
10. Fluoropolymer Three Coat System: 0.65 mil color base coat and Primer with a 0.05 mil PVDF ink coat and a 0.45 nominal PVDF fluoropolymer clear coat.
a. Basis of Design: CENTRIA Allusion.
11. Fluoropolymer Two Coat System: 0.2 mil primer with a 0.8 mil PVDF matte, low gloss color coat with fine aggregate finish.
a. Basis of Design: CENTRIA Allura.
F. Color:
Specifier: Retain one or both subparagraphs below has required for Project.
1. Interior Exposed Surface: [As indicated] [As selected by Architect from manufacturer's
standard colors] [Match Architect's custom color].
2. Concealed Surface: Manufacturer's standard primer color.
2.6 METAL WALL PANEL ACCESSORIES
Specifier: Retain paragraph below when metal wall panels are used in conjunction with CENTRIA MetalWrap metal wall panel backup system, which provides a one-step insulated substrate
incorporating watertight joints and air/vapor control.
A. Metal Wall Panel Backup System: Refer to Division 07 Section "Insulated-Composite
Backup Panel System."
B. Metal Wall Panel Accessories, General: Provide complete metal wall panel assembly
incorporating trim, copings, fasciae, parapet caps, soffits, sills, inside and outside corners, and miscellaneous flashings. Provide manufacturer's factory-formed shims, flashings, gaskets, & lap
strips for a complete installation. Fabricate accessories in accordance with SMACNA Manual.
Specifier: CENTRIA offers Microline Extrusions, an extensive line of complementary extruded trims that integrate both visually and mechanically with CENTRIA profile panels when used in horizontal
applications.
C. Extruded Trim: Manufacturer's complementary aluminum extrusions for head, jamb, sill, base,
flush, reveal, inside and outside corner, end wall, and expansion joint details. Finish to match
metal wall panels.
1. Basis of Design: CENTRIA, Microline Extrusions.
Specifier: CENTRIA offers MicroSeam Corners, a popular design feature that accentuates horizontal
lines by eliminating trim at corners.
CENTRIA 07 42 13 Metal Wall Panels Page 16 of 18
D. Mitered Corners: Structurally-bonded horizontal interior and exterior trimless corners matching
metal wall panel material, profile, and factory-applied finish, fabricated and finished by metal wall panel manufacturer.
1. Welded, riveted, fastened, or field- fabricated corners do not meet the requirements of this specification.
2. Basis of Design: CENTRIA, MicroSeam Corners.
E. Formed Flashing and Trim: Match material, thickness, and color of metal wall panels.
F. Sealants: Type recommended by metal wall panel manufacturer for application, meeting
requirements of Division 07 Section "Joint Sealants."
G. Flashing Tape: 4-inch wide self-adhering butyl flashing tape.
H. Fasteners: Self-tapping screws and other acceptable fasteners recommended by panel manufacturer. Where exposed fasteners cannot be avoided, supply stainless steel fasteners
with heads matching color of metal wall panels by means factory-applied coating.
2.7 SECONDARY METAL SUBGIRT FRAMING
A. Miscellaneous Framing Components, General: Cold-formed metallic-coated steel sheet,
ASTM A 653/A 653M, G90 (Z180).
1. Hat Channels: 0.06 inch/16 ga. (1.52 mm) minimum – nominal thickness.
2. Sill Channels: 0.06 inch/16 ga. (1.52 mm) minimum – nominal thickness.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine metal wall panel substrate with Installer present. Inspect for erection tolerances and other conditions that would adversely affect installation of metal wall panels.
B. Wall Substrate: Confirm that wall substrate is within tolerances acceptable to metal wall panel system manufacturer.
1. Maximum deviations acceptable:
a. 1/4-inch in 20 feet (6.4 mm in 6 m) vertically or horizontally from face plane of framing.
b. 1/2-inch (12.7 mm) across building elevation. c. 1/8-inch in 5 feet (3.2 mm in 1.5 m).
Specifier: Retain one, two, or three following paragraphs as appropriate to Project.
C. Framing: Inspect framing that will support metal wall panels to determine if support components are installed as indicated on approved shop drawings. Confirm presence of
acceptable framing members at recommended spacing to match installation requirements of metal wall panels.
CENTRIA 07 42 13 Metal Wall Panels Page 17 of 18
D. Openings: Verify that window, door, louver and other penetrations match layout on shop
drawings.
E. Air/Moisture Barriers: Confirm that work has been completed, inspected, and tested as
required.
F. Advise G.C., in writing, of out-of-tolerance work and other deficient conditions prior to
proceeding with metal wall panel system installation.
G. Correct out of tolerance work and other deficient conditions prior to proceeding with panel installation.
3.2 SECONDARY FRAMING INSTALLATION
Specifier: Retain article if secondary framing is part of work of this Section.
A. Secondary Metal Subgirt Framing: Install secondary metal framing components to tolerances indicated, as shown on approved shop drawings. Install secondary metal framing and other
metal panel supports per ASTM C 1007 and metal wall panel manufacturer's recommendations.
3.3 METAL WALL PANEL INSTALLATION
A. General: Install metal wall panels in accordance with approved shop drawings and
manufacturer's recommendations. Install metal wall panels in orientation, sizes, and locations indicated. Anchor metal wall panels and other components securely in place. Provide for
thermal and structural movement
Specifier: Retain paragraph below if utilizing CENTRIA MetalWrap panels.
1. Insulated-Composite Metal Wall Backup Panels: Install in accordance with
requirements of Division 07 Section "Insulated-Composite Backup Panel System."
B. Attach panels to metal framing using recommended clips, screws, fasteners, sealants, and
adhesives indicated on approved shop drawings.
1. Fasteners for Steel Wall Panels: Stainless-steel for exterior locations and locations
exposed to moisture; carbon steel for interior use only.
2. Fasten metal wall panels to supports with fasteners and spacing recommended by manufacturer.
3. Provide weatherproof escutcheons for pipe and conduit penetrating exterior walls. 4. Dissimilar Materials: Where elements of metal wall panel system will come into contact
with dissimilar materials, treat faces and edges in contact with dissimilar materials as
recommended by manufacturer.
C. Joint Sealers: Install joint sealants where indicated on approved shop drawings.
3.4 ACCESSORY INSTALLATION
A. General: Install metal wall panel accessories with positive anchorage to building and provide
for thermal expansion. Coordinate installation with flashings and other components.
1. Install related flashings and sheet metal trim per requirements of Division 07 Section "Sheet Metal Flashing and Trim."
CENTRIA 07 42 13 Metal Wall Panels Page 18 of 18
2. Install components required for a complete metal wall panel assembly, including trim,
copings, corners, lap strips, flashings, sealants, fillers, closure strips, and similar items. 3. Comply with performance requirements and manufacturer's written installation
instructions. 4. Provide concealed fasteners except where noted on approved shop drawings.
5. Set units true to line and level as indicated.
3.5 FIELD QUALITY CONTROL
Specifier: Retain paragraph below when scope and complexity of metal wall panel installation justifies
inspection expense.
A. Manufacturer's Field Service: Engage a service representative authorized by metal wall panel
manufacturer to inspect completed installation. Submit written report.
B. Correct deficiencies noted in manufacturer's report.
3.6 CLEANING AND PROTECTION
A. Remove temporary protective films. Clean finished surfaces as recommended by metal wall panel manufacturer. Clear weep holes and drainage channels of obstructions, dirt, and sealant.
Maintain in a clean condition during construction.
B. Replace damaged panels and accessories that cannot be repaired by finish touch-up or minor
repair.
END OF SECTION