certafluxplm ii gen1 - philips · certaflux plm 2. certaflux plm 3. certaflux plm 2. certaflux plm...

12
CertaFluxPLM II Gen1 April. 2014

Upload: dinhnga

Post on 11-May-2018

229 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CertaFluxPLM II Gen1 - Philips · CertaFlux PLM 2. CertaFlux PLM 3. CertaFlux PLM 2. CertaFlux PLM tion t IIGen1 ... 0.330 0.340 0.350 0.360 0.370 0.380 0.390 0.400 0.410 0.420 C

CertaFluxPLM II Gen1 April. 2014

Page 2: CertaFluxPLM II Gen1 - Philips · CertaFlux PLM 2. CertaFlux PLM 3. CertaFlux PLM 2. CertaFlux PLM tion t IIGen1 ... 0.330 0.340 0.350 0.360 0.370 0.380 0.390 0.400 0.410 0.420 C

Int

Figure

Figure

Figure

Table

troduc

1. CertaFlux PLM

2. CertaFlux PLM

3. CertaFlux PLM

2. CertaFlux PLM

ction t

M IIGen1

M 1-3 multi-conne

M 1-5 multi-conne

II system with fix

to the

ector

ector

xed Xitanium LED

e Cert

ApplicatThe Philipapplication ProductTo operat• One • Speci• Com ClassificaThe Certa• Class

The Cer

Table 1. Ce

Product

CertaFlux

CertaFlux

CertaFlux

CertaFlux

CertaFl The followIIoutdoor local sales

D drivers, Class I c

taflux

tions s CertaFlux PLns.

t descriptionte a system youor more Certaified connectorpatible Xitanium

ation aFlux PLM II Ges I IEC isolation

IMPORTA• Tcase ,max

• ∆T (Tam

• Failure

rtaFlux PLM

rtaFlux PLM II and

x PLM II 3000lm 7

x PLM II 3000lm 8

x PLM 1-3 multi-c

x PLM 1-5 multi-c

ux PLM II sy

wing drivers are modules.If oth representative

compliant

PLM

M II Gen1 has b

n u will need the faFlux PLM IILEDs, Table1 m LED driver, T

en1 with Xitani systems

NT USAGE Nx must not excembient-Tcase) musto comply with

M II system c

d 1-n multi-conne

740 Gen1

850 Gen1

connector

connector

ystem with X

e highly recommer drivers are c

e for further co

II Gen

been developed

following produD modules, Tab

Table 2

um driver listed

NOTES eed 75°C for Tt not exceed 4

h usage conditio

components

ector

GPC

929000895

929000901

929000895

929000896

Xitanium LE

mended to opeconnected to P

onfirmation, it c

n1

d primarily for

ucts, which are ble1

d below can be

Ta 30oC 5°C ons will void pr

s

5808

108

5908

6008

ED drivers, C

rate theCertaFPLM II, please coan void warran

outdoor

sold separately

e used in:

roduct warranty

Class I

luxPLM ontact with younty.

1

y:

y

ur

Page 3: CertaFluxPLM II Gen1 - Philips · CertaFlux PLM 2. CertaFlux PLM 3. CertaFlux PLM 2. CertaFlux PLM tion t IIGen1 ... 0.330 0.340 0.350 0.360 0.370 0.380 0.390 0.400 0.410 0.420 C

2

Number of CertaFlux PLM II (any type)

Max output current (mA)

Driver GPC Cable

3x-5x 700 Xitanium150W 0.70A 230V IP67 929000846108 1x CertaFlux PLM 1-5 multi-connector 1x CertaFlux PLM 1-3 multi-connector

Xitanium 150W 0.70A 230V-6P I67 929000897108

Xitanium150W 0.70A 1-10V IP66 929000899808

2x 700 Xitanium 75W 0.70A 230VIP67 929000846608 1x CertaFlux PLM 1-3 multi-connector

Xitanium 75W 0.70A 230V-3P I67 929000897208

1x 700 Xitanium 50W 0.7A 230V IP67 929000846908 No additional Cable needed

Table2 includes fix output and single output dimmable drivers, for non IP66 drivers

i.e. IP42 150W, please contact with local sale representative. As the Xitanium LED driver portfolio is always expanding to include new products, please visit www.philips.com/xitanium or contact your Philips sales representatives for the latest system combinations.

Page 4: CertaFluxPLM II Gen1 - Philips · CertaFlux PLM 2. CertaFlux PLM 3. CertaFlux PLM 2. CertaFlux PLM tion t IIGen1 ... 0.330 0.340 0.350 0.360 0.370 0.380 0.390 0.400 0.410 0.420 C

3

Performance specification

The following paragraphs contain the performance specifications of the

CertaFluxPLM IIGen1 modules. Typical operating conditions

Table 3. Typical operating conditions

Item Symbol Unit Value Description

Default Driver current Idriver mA 700 Fixed output driver current

Case temperature Tcase °C 65 Case temperature: typical temperature at which the module operates within specs

Ambient temperature Tamb °C 30 Ambient temperature outside luminaire

Note:

• Philips maintains a tolerance of ±6.5% on luminous flux measurements, ±0.06 V on forward voltage measurements, ±2 on CRI measurements and ±5% on CCT measurements

Performance specifications CertaFlux PLM II 3000lm 740 Gen1 CertaFlux PLM II 3000lm 740 Gen1performance at 700mA and Tcase= 65°C

Table 4. Performance specification of the CertaFlux PLM II 3000lm 740 Gen1under typical operating conditions (If = 700 mA and Tcase = 65 °C).

Item Min Typ Max Unit

Initial lumen output 2700 3000 3300 lm

Initial efficacy 102 119 lm/W

Forward voltage 36 38 V

Initial power consumption 23.8 25.2 26.6 W

Correlated Color Temperature (CCT) - 4000 - K

Color Rendering Index (CRI) 70 - Ra

Initial color accuracy - 6 SDCM

Operating Ta range -30 50 oC

Weight 0.6 Kg

Approbation CQC,CE,CB, ENEC

IP rating IP66

Insulation class III

Page 5: CertaFluxPLM II Gen1 - Philips · CertaFlux PLM 2. CertaFlux PLM 3. CertaFlux PLM 2. CertaFlux PLM tion t IIGen1 ... 0.330 0.340 0.350 0.360 0.370 0.380 0.390 0.400 0.410 0.420 C

Figudriv

Pe Ce

Tab= 7

It

In

In

Fo

In

C

C

In

O

W

A

IP

In

IMPO•

ure4. Estimated mver current 700 m

erformance s

ertaFlux PLM I

ble 5. Performance700 mA and Tcase

tem

nitial lumen outpu

nitial efficacy

orward voltage

nitial power consu

orrelated color t

olor Rendering I

nitial color accura

Operating Ta rang

Weight

pprobation

P rating

nsulation class

ORTANT USPLM Systems wClass I luminairthe driver is nelocal Philips sal

module flux and mmA and various cas

specification

II 3000lm 850

e specification of te = 65°C).

ut

umption

temperature (CC

ndex (CRI)

acy

ge

SAGE NOTESwith recommenres only. For Ceeded. Design-ies representati

odule efficacy of tse Temperatures

ns CertaFlux

0 Gen1 perfor

the CertaFlux PLM

Min

2550

96

-

23.8

CT) -

80

-

-30

CQC

IP66

III

S nded Xitaniumdlass II luminairen support is avive for addition

the CertaFlux PLM(Tcase)

x PLM II 300

rmance at 700

M II 3000lm 850 u

Typ

2850

113

36.1

25.3

5000

C,CE,CB, ENEC

drivers should bes additional isovailable please cnal information.

M II 3000lm 740 G

00lm 850 Ge

0mA and Tcase=

under typical ope

Max U

3300 lm

138 lm

38 V

26.6 W

- K

- R

6 S

50 oC

0.6 K

be installed in olation layer forontact your

Gen1under typica

en1

= 65 °C

erating conditions

Unit

m

m/W

V

W

K

Ra

DCM

C

Kg

4

r

al

(If

Page 6: CertaFluxPLM II Gen1 - Philips · CertaFlux PLM 2. CertaFlux PLM 3. CertaFlux PLM 2. CertaFlux PLM tion t IIGen1 ... 0.330 0.340 0.350 0.360 0.370 0.380 0.390 0.400 0.410 0.420 C

Figudriv

Sp

Figu

IMPO•

ure 5. Estimated mver current 700 m

pecified lifeti

ures 6. show the e

ORTANT USPLM Systems wClass I luminair

module flux and mmA and various cas

ime perform

expected lumen m

SAGE NOTESwith recommenres only.

module efficacy of se Temperatures

mance

maintenance over

S nded Xitanium d

f the CertaFlux PL(Tcase)

r a typical product

drivers should b

LM II 3000lm 850

t (both 850 and 7

be installed in

Gen1under typic

740 as well) lifetim

5

cal

me

Page 7: CertaFluxPLM II Gen1 - Philips · CertaFlux PLM 2. CertaFlux PLM 3. CertaFlux PLM 2. CertaFlux PLM tion t IIGen1 ... 0.330 0.340 0.350 0.360 0.370 0.380 0.390 0.400 0.410 0.420 C

O

Figure

ptical

7. CertaFluxPLM

distrib

II

butionns

Optica

PLM II is

Figure 9.Ex

al performan

F

s designed for

xample of applicat

N.B. • C

swp(v

nce of Certa

Figures 8. Polar in

r narrow road

tion rendering, PL

Component andsymmetrical lighwill have minimaperformance in e.g. light from n

visible for the h

aFluxPLM II

ntensity diagram, P

ds and urban s

LM II

d process tolerht distributions.al impact on op the final applicneighboring pouman eye).

Gen1

PLM II Gen1

street lighting

rances can resu. Maximum accptical distributioation for a variles, flux differen

.

lt in imperfectlyeptable toleranons and optical ety of reasons nces < 20% not

6

y nces

t

Page 8: CertaFluxPLM II Gen1 - Philips · CertaFlux PLM 2. CertaFlux PLM 3. CertaFlux PLM 2. CertaFlux PLM tion t IIGen1 ... 0.330 0.340 0.350 0.360 0.370 0.380 0.390 0.400 0.410 0.420 C

Figure

Figure installa

Figure installa

10: Specified inst

11: Application reation

12: Application reation

allation paramete

endering of 10m

endering of 15m

ers

road with single

road with single

Recom The recoexamplesdistance For roadRoad typ

SON-T We propPLM 300the requ

Remark

SON-T We propPLM 300the requ

• Ata

mmendations

ommendations s as mentioned (P), tilt angle (T

d properties thepe: Asphalt pave

150W replac

pose to replace00lm and 1 Xitairement of stan

k: CJJ45-2006

250W replac

pose to replace00lm and 1 Xitairement of stan

All polar intensithe beam shapeavailable on the

s for SON-T

are made by m in tables x,x x.T) and overhan

e following settement ;Reflectio

cement soluti

e a 150W SONanium 150W IP6ndard for lightin

is regulation

cement soluti

e a 250W SONanium 150W IP6ndard for lightin

ity diagramilluste. We suggest m CertaFlux PLM

T replaceme

eans of Dialux . The road widtg (O) are speci

ings have been on table: CIE R

ion

-T conventiona67driver. The rng design of urb

of China

ion

-T conventiona67driver. The rng design of urb

trations are jusmaking use of thM II module we

nts

simulations forth (w), pole heiified per applica

used for all thrR3; Q0 of table:

al luminaire witrecommended sban road in Chi

al luminaire witrecommended sban road in Chi

t an indication he IES files bsite.

r specific road ight (H), pole ation.

ree applications 0.07;

h a system of 3system can meena.

h a system of 5system can meena.

7

of

s;

3 x et

5 x et

Page 9: CertaFluxPLM II Gen1 - Philips · CertaFlux PLM 2. CertaFlux PLM 3. CertaFlux PLM 2. CertaFlux PLM tion t IIGen1 ... 0.330 0.340 0.350 0.360 0.370 0.380 0.390 0.400 0.410 0.420 C

Figure 19m ro

Figure

13: Application reoad and central re

14: Road applicat

endering with doueserve

tion with 4 lanes a

uble installation o

and central reserv

SON-T

of

ve

We propPLM 300the requ

400W replac

pose to replace00lm and 2 Xitairement of stan

cement soluti

e a 400W SONanium 150W IP6ndard for lightin

ion

-T conventiona67 drivers. Theng design of urb

al luminaire wite recommendedban road in Chi

h a system of 8d system can mna.

8

8 x meet

Page 10: CertaFluxPLM II Gen1 - Philips · CertaFlux PLM 2. CertaFlux PLM 3. CertaFlux PLM 2. CertaFlux PLM tion t IIGen1 ... 0.330 0.340 0.350 0.360 0.370 0.380 0.390 0.400 0.410 0.420 C

0.340

0.350

0.360

0.370

0.380

0.390

0.400

0.330 0.340 0.350 0.360 0.370 0.380 0.390 0.400 0.410 0.420

Cie

y

Cie x

CRI70 4000K6.0 SDCMCRI80 5000K6.0 SDCMBBL

Page 11: CertaFluxPLM II Gen1 - Philips · CertaFlux PLM 2. CertaFlux PLM 3. CertaFlux PLM 2. CertaFlux PLM tion t IIGen1 ... 0.330 0.340 0.350 0.360 0.370 0.380 0.390 0.400 0.410 0.420 C

Pr

Figure

roduct

16.CertaFlux PLM

t dime

M II (any type)

ension

D

D

ns

Dimensions o

Dimensions o

Figure17. C

Figure 18. C

Module Ty

CertaFlux P

of CertaFlux P

of connecting

ertaFlux PLM 1-3

CertaFlux PLM 1-5

ype

PLM II 3000lm Ge

PLM II

cable

multi-connector

5 multi-connector

A1

en1 300

r

A2 B

0 286 7

B1 C1

70 69

1

C2 D1

44 30

10

Page 12: CertaFluxPLM II Gen1 - Philips · CertaFlux PLM 2. CertaFlux PLM 3. CertaFlux PLM 2. CertaFlux PLM tion t IIGen1 ... 0.330 0.340 0.350 0.360 0.370 0.380 0.390 0.400 0.410 0.420 C

© 2014 Philips LightingAll rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent or other industrial or intellectual property rights.

04/2014www.philips.com