(UK/0126/0010) MI-005 United Kingdom of Great Britain and Northern Ireland Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State for Business, Innovation & Skills Notified Body Number 0126 In accordance with the requirements of the Measuring Instruments (Liquid Fuel delivered from Road Tankers) Regulations 2006 (SI 2006/1259) and the Measuring Instruments (Non- Prescribed Instruments) Regulations 2006 (SI 2006/1270) which implement, in the United Kingdom, Council Directive 2004/22/EC, this certificate of EC type-examination has been issued to: Talleres Angel Torres S.L. C/. Automocion, 36 Pol. Ind. Calonge 41007 Sevilla Spain in respect of a static or vehicle-mounted meter measuring system for liquids other than water designated the TAT-S3 and TAT-S4 and having the characteristics as described in the descriptive annex. The necessary data (principal characteristics, alterations, securing, functioning etc) for identification purposes and conditions (when applicable) are set out in the descriptive annex to this certificate. This revision replaces previous versions of the certificate. Signatory: P Dixon for Chief Executive National Weights & Measures Laboratory (Part of the National Measurement Office) Department for Business, Innovation & Skills Stanton Avenue Issue Date: 01 June 2010 Teddington Valid Until: 11 June 2017 Middlesex TW11 0JZ Reference No: T1121/0018 United Kingdom

Upload: others

Post on 30-Apr-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State

(UK/0126/0010)

MI-005

United Kingdom of Great Britain and Northern Ireland

Certificate of EC type-examination of a

measuring instrument

Number: UK/0126/0010 Revision 3 issued by the Secretary of State for Business, Innovation & Skills

Notified Body Number 0126

In accordance with the requirements of the Measuring Instruments (Liquid Fuel delivered

from Road Tankers) Regulations 2006 (SI 2006/1259) and the Measuring Instruments (Non-

Prescribed Instruments) Regulations 2006 (SI 2006/1270) which implement, in the United

Kingdom, Council Directive 2004/22/EC, this certificate of EC type-examination has been

issued to:

Talleres Angel Torres S.L.

C/. Automocion, 36

Pol. Ind. Calonge

41007 Sevilla

Spain

in respect of a static or vehicle-mounted meter measuring system for liquids other than water

designated the TAT-S3 and TAT-S4 and having the characteristics as described in the

descriptive annex.

The necessary data (principal characteristics, alterations, securing, functioning etc) for

identification purposes and conditions (when applicable) are set out in the descriptive annex

to this certificate.

This revision replaces previous versions of the certificate.

Signatory: P Dixon for Chief Executive

National Weights & Measures Laboratory

(Part of the National Measurement Office)

Department for Business, Innovation & Skills

Stanton Avenue

Issue Date: 01 June 2010 Teddington

Valid Until: 11 June 2017 Middlesex TW11 0JZ

Reference No: T1121/0018 United Kingdom

Page 2: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State

Descriptive Annex

1 INTRODUCTION This pattern is a meter measuring system for static use or for fitting to a road tanker for the transport and delivery of liquids other than water of low viscosity stored at atmospheric pressure. It comprises a pump, a gas extractor, a meter with a full hose reel and/or an empty hose according to type (paragraph 2). The register may be either electronic or mechanical with a printer. The system allows:

a. Metered delivery by pumping (full or empty hose)

b. Direct delivery, with or without pumping, without passing through the meter.

c. Self loading with system pump, without passing through the meter.

d. Tank loading without passing through the meter. External pump required.

e. Metered delivery with external pumping (full or empty hose)

2 FUNCTIONAL DESCRIPTION

The designation TAT-S3 applies to assemblies with one or more full hoses only. The

designation TAT-S4 applies to assemblies with at least one empty hose. The hydraulic

systems for both types are shown in Figures 1 and 2 respectively. Both types may be either

38mm, 50 mm, 75mm or 100 mm systems. Typical layouts for truck and static applications

are shown in Figures 3 and 4.

Systems using an external pump must be fitted with a flow controlling / limiting valve as

shown in Figure 8, the flow rate is adjusted to ensure the flow does not exceed Qmax.

2.1 List of gas extractors

Manufacturer Model designation Evaluation

certificate

Total Control Systems TCS 682-15 series GB-1275

Total Control Systems TCS 740-xx series GB-1273

2.2 List of meters

Manufacturer Model designation Evaluation

certificate

Total Control Systems TCS 682-15 series GB-1275

Total Control Systems TCS 700-xx series GB-1273

Page 3: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State

2.3 List of registers and ancillary devices

Manufacturer Device Type Model

designation

Evaluation certificate

Veeder Root Register Mechanical 7887 Covered by this approval

Veeder Root Preset

(optional) Mechanical 7889 Covered by this approval

Veeder Root Printer Mechanical 7888 Covered by this approval

Veeder Root Register Electronic EMR³ GB-1285

Any Simple

slip printer

Electronic Any Covered by this approval

3 TECHNICAL DATA

3.1 System

Technical data Field of operation

Accuracy class 0.5

Minimum rate of flow See table in section 3.2

Maximum working

pressure:

10.5 bar

Minimum delivery (MMQ): See table in section 3.2

Temperature range -10°C to +40°C

Type of liquid Liquids other than water of low viscosity

(<20mPa.s) except liquefied gases.

(refer to manufacturers specifications for

suitable products)

The maximum rate of flow, however, must not be greater than the maximum rate of flow of

any component of the system.

3.2 Meters

Model

designation Size Flow rate range MMQ

(mm)

Qmin

(L/min)

Qmax

(L/min)

(L)

TCS 682-15 38 10 187 10

TCS 700-15 38 32 226 10

TCS 700-20 50 50 380 50

TCS 700-25 50 50 550 50

TCS 700-30 75 100 760 100

TCS 700-35 75 100 1155 100

TCS 700-40 100 151 1893 200

TCS 700-45 100 151 2271 200

Page 4: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State

4 APPROVAL CONDITIONS

The certificate is issued subject to the following conditions:

4.1 Legends and inscriptions

The following legends are durably and legibly marked on a plate attached to the system (see

Figure 5 for an example):

Manufacturer’s name: Talleres Angel Torres

Manufacturers designation: TAT-S3x or TAT-S4x

Serial number:

Date of manufacture:

Accuracy class: 0.5

Liquids measured:

Flow rate range: L/min

Minimum delivery: 50 or 100 litres

Maximum operating pressure: 10.5 bar

Environment1 -10°C/+40°C, H2 or H3, M1 or M3

Metrology markings: CE-mark

Supplementary metrology marking

Notified Body verification mark

UK/0126/0010

5 LOCATION OF SEALS AND VERIFICATION MARKS

5.1 The CE marking shall be impossible to remove without damaging it. The

labels shall be impossible to remove without them being destroyed.

The markings and inscriptions shall fulfil the requirements of Paragraph 9 of Annex I of the

Directive 2004/22/EC.

5.2 Components that may not be dismantled or adjusted by the user will be

secured by either a wire and seal or tamper evident label and securing mark. The securing

mark may be either:

− a mark of the manufacturer and/or manufacturer’s representative, or

− an official mark of a verification officer.

1 H2 = indoor, H3 = outdoor, M1 = static use, M3 = vehicle mounted.

Page 5: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State

5.2.1 The following items shall be secured:

(a) the components of the system in accordance with the requirements of the

relevant pattern approvals.

(b) the components of the system as described below and shown in Figures 6, 7

and 8.

5.2.1.1 Meter Assembly

Seals common to both TAT-S3 and TAT-S4 systems:

P1 – Seals screws fixing air eliminator to filter housing.

P2 – Seals air eliminator (front/rear) cover screws to gas removal pipe fitting.

P3 – Seals screws fixing filter to meter housing.

P4 – Seals screws fixing front cover to meter housing.

P5 – Seals screws fixing rear cover to meter housing.

P6 – Seals screws at preset’s side cover (cut-off adjuster).

P7 – Seals front cover screws at adjuster/transmission assembly housing (head support).

P8 – Seals screws fixing register head enclosure to its support.

P9 – Seals screws fixing preset valve to meter housing.

P10 – Seals screws fixing register enclosure (and printer when installed) to preset enclosure.

P11 – Seals preset valve top cover screws.

P12 – Seals screws fixing air-check valve to preset valve.

P13 – Seals air-check valve screws to gas removal pipe fitting toward air eliminator.

P14 – Seals air eliminator (front/rear) cover screws on side not attached to gas removal pipe

(typically used for vapour recovery or venting purposes).

5.2.2 Transfer points

The remaining seals downstream of the meter assembly shall be specific for each system

outflow alternative, which will obviously depend on the desired transfer point(s).

As detailed above, any connection installed between the outflow of the meter assembly and

the final transfer point(s) at any measuring system shall be protected from tampering or

fraudulent use. In order to achieve this, the general premise shall be to seal every joint,

flange, valve, pipework, etc. downstream of the meter assembly up to the end delivery

point(s) installed.

For that purpose, the additional seals for every type of measuring system shall match

precisely the following description:

Page 6: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State

5.2.2.1 TAT-S3 measuring systems with one full hose

P15 – Seals air-check valve screws to pipework inlet flange.

P16 – Seals pipework outlet flange to full hose assembly inlet flange (hose reel, etc.).

P17, P18, … – Seals additional flanges along full hose layout as required (long

pipework, curves, elastic joints, etc.)

5.2.2.2 TAT-S3 measuring systems with two or more full hoses

P15 – Seals air-check valve screws to pipework inlet flange.

P16 – Seals pipework outlet flange to 3-way valve inlet flange.

P17 – Seals 3-way valve first outlet flange to full hose assembly #1 inlet flange.

P18 – Seals 3-way valve second outlet flange to full hose assembly #2 inlet flange.

P19, P20, … - Seals additional flanges along full hoses layouts as required (long

pipework, curves, elastic joints, etc.)

5.2.2.3 TAT-S4 measuring systems with one empty hose

P15 – Seals air-check valve screws to pipework inlet flange.

5.2.2.4 TAT-S4 measuring systems with one or more empty hose(s) and one or more

full hose(s) if installed

P15 – Seals air-check valve screws to pipework inlet flange.

P16 – Seals pipework outlet flange to 3-way valve inlet flange.

P17 – Seals 3-way valve first outlet flange to empty hose assembly inlet flange.

P18 – Seals 3-way valve second outlet flange to full hose assembly inlet flange.

P19, P20, … - Seals additional connections along empty / full hoses layouts as

required (flanged pipework, elastic joints, etc.)

5.2.2.5 TAT-S3 and TAT-S4 measuring systems with external pumping

Prior to sealing the flow controlling / limiting valve is adjusted to ensure the maximum flow

rate (Qmax) of the system cannot be exceeded.

The adjusting screw of the reducing valve is sealed to the cover plate screws with one single

seal. The inlet and outlet flanges are also sealed to prevent their removal (Figure 8).

Page 7: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State

6 PRODUCT RETURN SYSTEM (FIGURE 9)

6.1 Operation

The product return system works in conjunction with the EMR3 headset. In order to avoid

uncontrolled deliveries, there shall be a mechanical device installed in the truck (a remote

stop function). This device could be a guard bar or any other suitable hardware intended for

the same purpose. When the operator activates this device, thus enabling transfer deliveries, it

will actuate on a master pneumatic valve that opens the airflow towards a pressure switch. A

schematic of the system is shown in Figure 10.

When triggered, the main pneumatic valve also generates pressurized airflow to the

pneumatic manifold, which controls product return to tanker compartments. By selecting the

desired product transfer inlet for a particular compartment, the corresponding 2-way valve

actuator will open to its product return position. If the mechanical device does not activate the

master pneumatic valve, the pneumatic transfer manifold will not receive air pressure to open

any return valve, thereby making it impossible to return product back to the tanker

compartments. Simultaneously the pressure switch generates a positive signal that is

processed by the mini PLC, which differentiates between normal or transfer deliveries. The

output signal from the mini PLC is sent to both the EMR3 Interconnection Box remote stop

relay and to the EMR3 headset display transfer relay. The wiring configurations are shown in

Figures 11 &12.

If a normal delivery is in progress, a change in delivery mode signal from the mini PLC will

immediately terminate the transaction, a ticket is printed and the EMR3 register goes into

“Return Mode” ready for a new transfer delivery.

While the mechanical device for return mode is active, all deliveries shall be treated as

product returns, and all delivery tickets will automatically bear the return legend on them. If

the return mechanical device is disabled the delivery is immediately terminated and the

transfer ticket printed automatically. The return system switches back to normal delivery

mode, ready for the next transaction.

6.2 Software and Security

The EMR3 register is configured by default to print a ticket every time the operator carries

out any product delivery. The return or transfer mode requires that a transfer switch is wired

to the EMR3 display head and that the Transfer Interlock option is enabled within the

Configure Input / Output Setup on the C&C menu (Configuration & Calibration), which is

protected against manipulation by W&M sealing.

The main pneumatic valve should be sealed. The remaining devices for the return system,

including the Veeder Root Interconnection Box, shall be installed within a sealed cabinet.

The Veeder Root EMR3 headset (display assembled directly to meter or remote display with

pulser on meter) also features its own W&M seal. The remote Veeder Root EMR3 headset

can be installed within the same sealed cabinet if required.

Page 8: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State

7 RECOMMENDED TESTS

The meter measuring system shall be tested at a minimum of two substantially different rates

of flow between the maximum and minimum rates of flow.

The meter measuring system shall be tested by a minimum of three repeat runs at each rate of

flow. Each run shall have a minimum duration of one minute.

Due regard shall be paid to the viscosity of the liquid used for the verification tests to ensure

that the permitted limits of error are not likely to be exceeded when other liquids which the

system is intended to measure are metered.

8 ILLUSTRATIONS

Figure 1 Hydraulic diagram TAT-S3

Figure 2 Hydraulic diagram TAT-S4

Figure 3 Typical layout for truck application

Figure 4 Typical layout for static application

Figure 5 Example of system identification plate

Figure 6 TAT-S3 seals

Figure 7 TAT-S4 seals

Figure 8 Flow controlling / limiting valve sealing arrangement

Figure 9 Product Return System

Figure 10 Product Return System Schematic

Figure 11 Wiring for Remote Stop Interconnection Box

Figure 12 Wiring for EMR3 with Product Return

Page 9: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State

9 CERTIFICATE HISTORY

ISSUE NO. DATE DESCRIPTION

UK/0126/0010 12 June 2007 Type examination certificate first issued.

UK/0126/0010 Revision 1 29 February 2008 Front page

- Clarification of liquid types

Section 1

- Clarification of liquid types.

- Addition of metered delivery with external

pumping (full or empty hose).

Section 2

- reference to evaluation certificates added

- EMR3 register added and electronic printer

Section 3

- System table modified, liquid types clarified

- meter table added

Section 4.1

- example of liquid type removed from

“liquids measured:”

Section 5

5.2.2.5 added

Section 7

Figure 8 added

UK/0126/0010 Revision 2 21 November 2008 Figure 2 - S4 schematic revised to provide

clearer description of system

UK/0126/0010 Revision 3 01 June 2010 Section 6

Product Return System added

Subsequent sections renumbered

Page 10: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State

R1 Two-way valve (optional). For gravity, un-metered delivery. Where this is fitted for trade use,

the compartments shall have dipstick measuring systems, subject to national regulations.

P Pump

R2 Two-way valve (optional). For pumped, un-metered delivery. Where this is fitted for trade

use, the compartments shall have dipstick measuring systems, subject to national regulations.

F Filter

Sg Air eliminator / gas extractor

C Meter

T1, T2 Gas removal pipes

Vm Closing / preset valve

Cl Air check / back pressure check / non-return valve

fl1 Full hose #1

fl2 Full hose #2 (optional)

cla Non--return valve (keeps hose full of liquid)

R3 Hose selection device (optional - allows product delivery through any of the full hoses

available. typically consists of a two-way valve pneumatically actuated by a switch device)

This type of system shall be capable of:

a) Product delivery flowing through the pump and the meter by one or more full hose(s).

b) Product delivery not flowing through the meter (with or without pump), emptying and filling of the tank(s)

not flowing through the meter.

c) Product delivery flowing through the meter (with or without pump), by one or more full hose(s).

Figure 1 Hydraulic diagram TAT–S3

Page 11: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State

This type of system shall be capable of:

a) Product delivery flowing through the pump and the meter by one or more empty hose(s),

optionally one or more full hose(s), or any combination of both.

b) Product delivery not flowing through the meter (with or without pump), emptying and

filling of the tank(s) not flowing through the meter.

c) Product delivery flowing through the meter (with or without pump), by one or more empty

hose(s), optionally one or more full hose(s), or any combination of both.

Figure 2 Hydraulic diagram TAT–S4

Page 12: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State

Figure 3 Typical layout for truck application

Page 13: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State

Figure 4 Typical layout for static application

Page 14: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State

Figure 5 Example of system identification plate

Page 15: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State
Page 16: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State

Figure 6 TAT-S3 seals

Page 17: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State

Figure 7 TAT-S4 seals

Figure 8 Flow controlling / limiting valve sealing arrangement

Page 18: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State

Figure 9 Product Return System

Figure 10 Product Return System Schematic

Page 19: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State

Figure 11 Wiring for Remote Stop Interconnection Box

Page 20: Certificate of EC type-examination of a measuring ... · Certificate of EC type-examination of a measuring instrument Number: UK/0126/0010 Revision 3 issued by the Secretary of State

Figure 12 Wiring for EMR3 with Product Return

© Crown copyright 2010

This material may be freely reproduced except for sale.