ASME CSD-1 Safety DevicesCF Controls FuelCombustion

1

ASME CSD-1Rules for boilers above400,000 btu input up to

12,500,000 btu input

9.5hp to 300hp Boilers

2

Open Book Test:ASME CSD-1 Is allowed tobe used.

ASME CSD-1-2009 Five Sections

General CG

TestingMaintenance

CMCombustion

CF

“CG” “CM” “CE” “CW” “CF”

TestingMaintenance

CM

Electrical CESteam

WatersideCW

CombustionCF

Burners 400,000 Btu input and under are exempt(10 Boiler hp, 3 gph oil, 115 kw electric)

All boilers must comply with CSD-1 sections CW & CE

Control compliance and operation based upon:400,000 to 2,500,000 Btu input

60 Boiler hp max.2,500,000 to 5,000,000 Btu input

120 Boiler hp max.5,000,000 to 12,500,000 Btu input

300 Boiler hp max.

ASME CSD-1 2009 “CF” Three DivisionsControls need to be provided and operate based upon the burner input rating

4

Burners 400,000 Btu input and under are exempt(10 Boiler hp, 3 gph oil, 115 kw electric)

All boilers must comply with CSD-1 sections CW & CE

Control compliance and operation based upon:400,000 to 2,500,000 Btu input

60 Boiler hp max.2,500,000 to 5,000,000 Btu input

120 Boiler hp max.5,000,000 to 12,500,000 Btu input

300 Boiler hp max.

Control DynamicsAction determined by burner size

• Purging• Safety Control Timing• Action On Flame Failure• Loss Of Combustion Air• Combustion Air Proving• Fuel Supervision

• Purging• Safety Control Timing• Action On Flame Failure• Loss Of Combustion Air• Combustion Air Proving• Fuel Supervision

5Radiant Realities

6

CF Controls FuelCSD-1 Control Safety Devices

7Radiant Realities

Radiant Realities 8

Radiant Realities 9

Radiant Realities 10

13

14

15

16

17

CF-150Manually

Operated GasShutoff Vales

CF-150Manually

Operated GasShutoff Vales

18

19

20

21

22

CF-160 Gas Pressure Regulators

23

25

CF-161 Overpressure ProtectionCF-162 Pressure Switches

26

27

28

CF-170 Control ValvesCF-180 Safety Shutoff Valves

30

31

32

33

34

CF-190Atmospheric Vents and Gas Vent, Bleed, or Relief Line

37

38

39

CF-200 Gas Fired Boiler Units Purging

40

41

42

43

44

CF-300Gas Fired Boiler Units Safety ControlCF-310Primary Safety Control

45

50

51

Pilot Gas

52

Pilot Gas

Main Gas

54

55

58

59

CF-400Oil Fired Burners

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

76

77

78

80