challenging applications demand kenall cie 88 2004, and depend upon the length of the tunnel, the...

20
TR LuxTran Tunnel Lighting Systems Transportation Lighting Designed and manufactured in the USA PROJECT: FDOT - Port of Miami Tunnel LOCATION: Miami, FL SPECIFIER: Jacobs Engineering

Upload: phamkhuong

Post on 12-Jun-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

TR

LuxTran™

Tunnel Lighting Systems

Transportation Lighting

Designed and manufactured in the USA

PROJECT: FDOT - Port of Miami TunnelLOCATION: Miami, FLSPECIFIER: Jacobs Engineering

Page 2: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

22 LuxTran™ Tunnel Lighting

Table of Contents

Custom Products. Expert Service. 3

Port of Miami Testimonial 4-5

Products Designed to Last for Decades 6

Built & Tested to Exceed Industry Standards 7

Understanding the Science of the Space 8

Tunnel Lighting Best Practices 9

What’s New in LED Tunnel Lighting 10

New LED Lighting with Remote Driver Option 11

Remote Driver Adds Convenient Servicing 12-13

Woodall Rodgers Testimonial 14-15

LuxTran™ Family of Tunnel Lighting 16-17

Ordering Information, Testing 18

Listings, Certifications & Warranty 19

Demand Kenall for Tunnel Lighting

Your goal when lighting a tunnel is to safely support the drivers’ comfort and visual perceptions. Tunnel lighting ranks among the most challenging of lighting applications. Not only does the intricate topology of a tunnel, with its “Black Hole” effect and critical transition zones require painstaking attention to detail, but also the tough, corrosive atmosphere caused by a combination of pollutants, moisture, chemicals, and galvanic couple differences (electrolytic ionization) add to the challenge.

Luminaires installed in this type of environment can deteriorate rapidly causing unsafe tunnel conditions. Reliable lighting designed to last for many years is critical, especially in an area where access is restricted and minimal maintenance is a must.

For these reasons, Kenall tunnel luminaires have been designed with your needs in mind, including stainless steel housings that last for decades and optimal light levels to ensure the safe flow of traffic throughout the tunnel.

Our new LuxTran™ LED luminaires are more powerful than their predecessors with lumen outputs ranging from 8,531 to 90,295—more than enough to obliterate the “Black Hole” effect—and LED life times up to 150,000 hours.

Because tunnel lighting must endure the most challenging environmental conditions, Kenall has applied over 50 years experience in designing, testing and manufacturing luminaires to meet and exceed the highest industry standards, including ANSI, CSI and NEMA, so you can specify Kenall tunnel luminaires with complete confidence.

Cover image by www.goldenduskphotography.com

• Over 50 years of expertise in developing stainless steel housings

• Lighting performance that meets and exceeds industry standards

• Optical control provides visual acuity for comfort and safety

• LED luminaires for increased energy savings and less maintenance

Challenging Applications... Demand Kenall™

Page 3: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

3LuxTran™ Tunnel Lighting 3

Custom Products. Expert Service.Because each tunnel has its own unique characteristics, Kenall specializes in customized tunnel lighting to meet your exact specifications and industry standards. Our expertise in service and support addresses the many complexities and challenges of lighting a tunnel. From clearly defined project objectives to product selection, design and layout assistance, our tunnel experts are available when you need them. Then, once your luminaires are ready for delivery, sequenced, palletized shipments with simple instructions support a flawless installation. The Kenall team is committed to taking the complexities out of tunnel lighting.

Page 4: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

4

Ready to Combat Corrosion?

Page 5: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

5Luxtran™ Tunnel Lighting 5LuxTran™ Tunnel Lighting

Kenall’s LuxTran is Up to the ChallengeTunnel lighting prepared to resist corrosion for decades

“The lighting provided for the Port of Miami Tunnel has met all of the performance requirements of the demanding specification prepared by the project designer and approved by the Florida Department of Transportation.”

— StevenDusseault,P.E. CEIResidentEngineer,FloridaDept.ofTransportation, PortofMiamiTunnelproject

PROJECT: FDOT - Port of Miami TunnelLOCATION: Miami, FLSPECIFIER: Jacobs EngineeringReadtheentirecasestudyatwww.kenall.com

Page 6: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

6

The Kenall product shown on this page is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof.

www. kenall.com P: 800-4-Kenall Email: [email protected] 10200 55th Street Kenosha, WI 53144

6 LuxTran™ Tunnel Lighting

Stainlesssteel,lockable,rotarylatchesandtethersallowfortool-lessaccesstotheelectricalcompartment.

Long-lifeLED(L70)to150,000hoursavailableinvariouswattagesandcolortemperatures.

Sealedpolycarbonateortemperedglasslensoptionsreduceglare.

Stainlesssteelhousingforsuperiorcorrosionresistance.

Fullysealedhousingwithmoldedorextrudedsolidsiliconegasketsensureingressprotection(IP)ratings.

Externalstainlesssteelmountingbracketsareadjustableandcustomizableforeaseofinstallation.

Passivationpost-weldingprotectsthestainlesssteelfromcorrosion.

Products Designed to Last for Decades

Note:Allstainlesspartsare316or304.

LuxTran™ Heat SinksLEDsarehousedinanisolatedaluminumheatsinktoeliminatethepossibilityofdissimilarmetalcorrosion.Doublesealedusinga5,000hoursaltsprayelectrodispositioncoatingandpowdercoating,theheatsinkisdesignedtolastthelifetimeoftheLEDs.

Page 7: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

7

The Kenall product shown on this page is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof.

www. kenall.com P: 800-4-Kenall Email: [email protected] 10200 55th Street Kenosha, WI 53144

LuxTran™ Tunnel Lighting

Built & Tested to Exceed Industry StandardsKenalldeliverstoughtunnellightingsystemsdesignedandmanufacturedintheUSAthatarebuiltandtestedtomeetorexceedindustrystandards.

• Stainless SteelKenall’sLuxTran™seriesisspecificallydesignedandmanufacturedtoeliminatecorrosionandlastfordecades.Usingonly316and304stainlesssteel,typicallyusedinmarineenvironments,ourtunnelproductsresistcorrosion,rustandstaining.

• Passivated WeldsWithformingandfabricationbeingtwoofourkeycompetencies,KenallensuresthatallweldsonLuxTranproductsarepassivated;restoringauniformchromiumoxidefilmonthematerial’ssurfacetoeliminatethepotentialforcorrosionorrouging.

• Custom Mounting BracketryUnlikemanyproductsintheindustry,mountingbracketsonKenall’sLuxTranproductscanbecustomizedtoyouruniquetunnelcharacteristics.

• Minimal Maintenance Kenall’sLuxTranLEDluminairesprovidelongerL70lifetimes—upto150,000hours—lasting5xlongerthantraditionaltunnelluminairesforreducedoperatingcostandmaintenance.

• Tested to Meet Certified Performance StandardsKenallLuxTranluminairesgothroughmanyrigoroustestingprocedurestomeetthefollowingindustrystandards:ANSIC136.27-2012temperaturecycling/100PSIwatertest,C136.31vibrationtesting,UL1598/A,CSA22.2,NEMA4Xrating,IP66ratingperIEC60598,aswellasIESNALM-79-08standardphotometrytesting.Seepage18foralistofKenall’sstandardtestingprocedures.

Page 8: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

–Uniformluminancethroughouttunnelinterior–Generallylowcontrastvalues–Maximizeswallluminances–Maximizescandlepowertowalls

–Uniformluminancethroughouttunnelinterior–Generallylowcontrastvalues–Maximizesfluxparalleltotrafficflow–Maximizescandlepowertovehicle

Counter Beam

Pro Beam

Symmetric

EG 2012

EG 2012

EG 2012

Counter Beam

Pro Beam

Symmetric

EG 2012

EG 2012

EG 2012

Lightthatradiatesatrightanglestotheaxisofthetunnel,directingit

evenlytothewalls

Lightthatradiatesparalleltotheaxisofthetunnel,distributingitparallelto

thetrafficflow

Transverse Lighting

8

The Kenall product shown on this page is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof.

www. kenall.com P: 800-4-Kenall Email: [email protected] 10200 55th Street Kenosha, WI 53144

8 LuxTran™ Tunnel Lighting

Fixation

The point from which the driver fi xates on the opening of the tunnel to identify tunnel roadway hazards. This is the point where adaptation begins.

Approach

During daytime hours, drivers’ eyes may have to adapt from over 10,000 footcandles to less than 1% of that level very quickly, while traveling at a high rate of speed. To facilitate this, the design must include the approach, which extends from the point that the tunnel opening becomes the principal feature in the driver’s fi eld of vision (also known as the adaptation point), to the actual entrance of the tunnel.

Adaptation Distance

The adaptation distance is the distance between the adaptation point and the portal. (The portal is the plane of entrance into the tunnel, where the roadway changes from uncovered to covered.)

Threshold Zone

The fi rst phase of visual adaptation occurs in the Threshold Zone as the driver enters the tunnel. The lighting levels in this zone are specifi ed in CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are present or the exit is visible.

Thehumaneyerequiresmoretimetoadaptfrombrightnesstodarknessthanthereverse.Forthisreason,tunnellightingmustgraduallytransitiontointeriorlightlevels.Duringnighttimehours,theareaoutsidethetunnelisdark,whereasinteriorlevels

Refer to ANSI/IES RP-22-11, Section 7.0 for complete lighting application techniques.

Axial Lighting

Understanding the Science of the Space

Types of Tunnel Lighting: Symmetrical Light Distributions for Tunnels

Approach

Adaptation Distance Threshold Zone Transition Zone Interior Exit Zone

A B C

1.45m(4.75ft)

1SSSD

Ø

Defi nition of tunnel topology reference: ANSI/IES RP-22-11, Section 2.0.

Tunnel Topology

Page 9: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

–Predominantlydistributedtowardsthedriver, butinacontrolledmannertoreduceglare–Provideshighpavementluminanceandlowobject luminancetoenhancenegativecontrast–Lightabove45°mustbestrictlycontrolled

–Minimalglaretowardsthedriver–Primarydisruptionisindirectionoftrafficflow–Provideshighobjectluminanceandlow pavementluminancetocreatepositivecontrast

Counter Beam

Pro Beam

Symmetric

EG 2012

EG 2012

EG 2012

Counter Beam

Pro Beam

Symmetric

EG 2012

EG 2012

EG 2012

Lightthatradiatesparalleltothetunnelaxisandagainstthedirectional

flowoftraffic

Lightthatradiatesparalleltothetunnel

axiswiththedirectionalflowoftraffic

9

The Kenall product shown on this page is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof.

www. kenall.com P: 800-4-Kenall Email: [email protected] 10200 55th Street Kenosha, WI 53144

LuxTran™ Tunnel Lighting

Transition Zone

The second zone inside the tunnel is the transition zone, in which ambient illumination decreases from the relatively high levels found in the Threshold Zone to the lower levels found in the Interior Zone. In this zone, the light levels are decreased in stages, allowing the driver’s eyes time to adapt. The total length of the Transition Zone may be equivalent to 25 seconds of travel time.

Interior

The Interior Zone is comprised of the light level required for the remainder of the tunnel, once eye adaptation has been completed in the preceding Transition Zone.

Exit Zone

The Exit Zone is not a requirement as per ANSI/IES RP-22-11. The eye’s ability to adapt from dark to light occurs very quickly, although higher light levels are sometimes specifi ed to help adapt back to higher exterior illuminance levels. Exit Zone lighting may or may not be required depending on local codes and practices.

Negative Contrast (Counter-Beam) Positive Contrast (Pro-Beam)

Types of Tunnel Lighting: Asymmetrical Light Distributions for Tunnels

aresimilartothoseofanilluminatedopenroadway;makingthetransitionminimal.Tunnellightingiscomprisedofdistinctzones,eachwithuniquelightingneedsasillustratedbelow.Foradetailedexplanation,refertoANSI/IESRP-22-11,Section2.0.

Approach

Adaptation Distance Threshold Zone Transition Zone Interior Exit Zone

A B C

1.45m(4.75ft)

1SSSD

Ø

T U N N E LT U N N E LT U N N E L

Tunnel Lighting Best Practices

Page 10: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

10

The Kenall product shown on this page is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof.

www. kenall.com P: 800-4-Kenall Email: [email protected] 10200 55th Street Kenosha, WI 53144

10 LuxTran™ Tunnel Lighting

NominalSize 11"×24";20"×33";33"×35"InstallationTypes Surface-CeilingorwallmountLampType LEDWattages 300W,390W,396W,600W,780W

LuxTran™ Drivers•Developedspecificallyfortunnellighting•Anodizedaluminumextrudedcase• 277-480VACtopology• 92%efficiency• 200,000hrMTBF(Telecordiastandard)• Sensitivecomponentscontaineddirectlyon heatsinkcompartment• Driverplacedonluminaireheatsinktocreateadirect pathtocoolingair• Flicker-freedimmingdownto1%;dim-to-dark(turn luminairesoffvia0-10vdcdimming)• Aluminumheatsinkgalvanicallyisolatedfromstainless steelenclosurebyasinglepiece1/8”thickDowCorning XiameterWhiteDurosiliconegasket• 90°Celsiusmaximumcasetemperature• 100W,200W,300W,and400Woutputleveloptions

What’s New in Tunnel Lighting?Kenallhasexpandeditsfamilyoftunnelluminairestoaddressarangeofspecializedneedstomeetyourspecifictunnelapplications.NewLEDlampoptionsnotonlyprovidemaintenance-friendlychoices,butalsoprovideadditionalenergysavings.

LTSI Series • Poweredbyintegraldriver• Suitableforinteriorandexteriorsupplementallightingin allzones• Corrosionresistant,one-piece,type304or316stainlesssteel housing;one-piece,seam-weldedconstruction• Stainlesssteeldoorframesecuredtohousingwith lockablestainlesssteelrotarylatches• Cleartemperedglassorpolycarbonatelens• Lumenrange27,434–90,295• TypeII,III,IV,IV-NarrowandV-Squaredistributions• Customizablemountingbracketsforeaseofinstallation• VibrationtestedtoANSIC136.31•WatertestedtoANSIC136.27-2012(100PSIwatertest)

LED

CADAIP66 3g NEMA

4X LED

100 PSI

ANSI C136.27

•Highestoutput• TypeVNarrowRound• 60°cutoff• Excellentintransitional applicationsover pedestrianorservice locations

39875

1

2

29906

19837

9969

29479

1

2

22109

14739

7370

45713

1

2

34285

22857

11429

32069

1

224049

16032

8016

20387

1

2

15291

10194

5097

49632

1

2

37224

24818

12408

Ceiling Mount Type V Square Ceiling Mount Type V Round Ceiling Mount Type II High Angle Ceiling Mount Type II Medium Angle Pro Beam ofr Counter Beam Type IV Forward Throw

Foradditionalperformancedataconsultspecsheetsatwww.kenall.com

*4000Kalsoavailablein80CRI

Single piece 1/8” thick Dow Corning Xiameter White Duro silicone gasket

#ofLED’s Lumens Watts Efficacy Color* CRI

96 27,434-43,836 215-426 86-128 4000-5700K 70

192 56,509-90,295 429-853 89-132 4000-5700K 70

Page 11: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

11

The Kenall product shown on this page is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof.

www. kenall.com P: 800-4-Kenall Email: [email protected] 10200 55th Street Kenosha, WI 53144

LuxTran™ Tunnel Lighting

NominalSize 10"×19";18"×19";18"×34"InstallationTypes Surface-CeilingorwallmountLampType LEDWattages 300W,390W,396W,600W,780W

LTL Series • Suitableforcontinuousrowmountinginallzones• PoweredbyRD700distributedDCdriversystem; remotelylocatedforservicingconvenience• Corrosionresistant,one-piece,type304or316stainlesssteel housing;one-piece,seam-weldedconstruction• Stainlesssteeldoorframesecuredtohousingwith lockablestainlesssteelrotarylatches• Cleartemperedglassorpolycarbonatelens• Lumenrange10,901–12,420• TypeII,Pro-Beam,TypeV-NarrowRoundand TypeV-Squaredistributions• Customizablemountingbracketsforeaseofinstallation• VibrationtestedtoANSIC136.31•WatertestedtoANSIC136.27-2012(100PSIwatertest)•NEMA4XRated

LTS Series • Suitableforsupplementallightingintransitionzones• PoweredbyRD700distributedDCdriversystem;remotely locatedforservicingconvenience• Corrosionresistant,one-piece,type304or316stainlesssteel housing;one-piece,seam-weldedconstruction• Stainlesssteeldoorframesecuredtohousingwith lockablestainlesssteelrotarylatches• Cleartemperedglassorpolycarbonatelens• Lumenrange27,434–90,295• TypeII,Pro-Beam,TypeV-NarrowRoundand TypeV-Squaredistributions• Customizablemountingbracketsforeaseofinstallation• VibrationtestedtoANSIC136.31•WatertestedtoANSIC136.27-2012(100PSIwatertest)•NEMA4XRated

NominalSize 10"×96"InstallationTypes Surface-CeilingorwallmountLampType LEDWattages 100W

New Lighting with Remote Driver OptionKenall’sLTLandLTSaremaintenancefriendly.Poweredbyaremotedriverinstalledatarmsreach,thesystemisdesignedtofacilitiateeaseofservicing.Seepages12and13foradditionalinformation.

100 PSI

ANSI C136.27

100 PSI

ANSI C136.27

LED

Foradditionalperformancedataconsultspecsheetsatwww.kenall.com

*4000Kalsoavailablein80CRI

• Highestoutput• TypeVSquare• 45°cutoff• Excellentinallzones

28742156

1437

719

1

2

2495418716

12477

62392

1

LTL LTS

•Highestoutput• TypeVNarrowRound• 60°cutoff• Excellentintransitional applicationsover pedestrianorservice locations

#ofLED’s Lumens Watts Efficacy Color* CRI

96 27,434-43,836 215-426 86-128 4000-5700K 70

192 56,509-90,295 429-853 89-132 4000-5700K 70

CADAIP66 3g NEMA

4X LED

CADAIP66 3g NEMA

4X LED39875

1

2

29906

19837

9969

29479

1

2

22109

14739

7370

45713

1

2

34285

22857

11429

32069

1

224049

16032

8016

20387

1

2

15291

10194

5097

49632

1

2

37224

24818

12408

Ceiling Mount Type V Square Ceiling Mount Type V Round Ceiling Mount Type II High Angle Ceiling Mount Type II Medium Angle Pro Beam ofr Counter Beam Type IV Forward Throw

#ofLED’s Lumens Watts Efficacy Color CRI

96 10,901-12,420 118 72-105 4000-5700K 65

Page 12: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

12

The Kenall product shown on this page is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof.

www. kenall.com P: 800-4-Kenall Email: [email protected] 10200 55th Street Kenosha, WI 53144

12 LuxTran™ Tunnel Lighting

Remote LED Driver Adds Convenient Servicing...TheRD700RemoteDriverpowersKenall’sLuxTran™LTLandLTSSeriesLEDluminairesforeaseofserviceability.Hot-swappabledriverscanbesimplyremovedorreplacedwithoutshuttingthesystemdown.Apatent-pending,tool-less,quick-releasemechanismalsomakesservicingthedriverseasy.

RD700 Series • RemotelypowersKenallLTLandLTSSeriesLED luminairesviaconstant-currentDC•Hot-swappable;servicedriverswithoutshutting downthepower• Simplifiedservicingofdriversviapatent-pending tool-less,quick-releasemechanism•Corrosionresistant,one-piece,type316or304 stainlesssteelhousing;one-piece, seam-weldedconstruction•High-efficiency(>90%)driverswithdedicatedheat sinksand20kVbuilt-insurgesuppressionfor long-lifeoperation•ULCertifiedIP66perIEC60598 NominalSize 42"×48"

InstallationTypes Surface-WallmountLampTypes LED

Kenall’s RD700 remote driver box installs on the tunnel’s interior wall for convenient servicingof luminaires.

Kenall’s patent-pending quick-release mechanism makes servicing the RD700 easy.

CADAIP66 3G NEMA

4X LED

Page 13: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

13

The Kenall product shown on this page is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof.

www. kenall.com P: 800-4-Kenall Email: [email protected] 10200 55th Street Kenosha, WI 53144

LuxTran™ Tunnel Lighting

Maintenancepersonnelwalkalongthecatwalktowardtheremotedriverforeasyservicing.WiresarerunalongthewallfromtheboxtotheluminairestoconnecttheremotedrivertoKenall’sLuxTran™LTLandLTSLEDtunnelluminairesasshowninthewiringschematicsbelow.Variouswiringconfigurationsaredependentonthetypeandamountoflightingfixturesinstalled.

...Without Shutting Down the TunnelWithKenall’sLuxTran™RD700remotedriver,younolongerhavetoshutdownthetunneltoserviceluminaires.Theremotedriverisinstalledlowontheinteriorwalltofacilitateeaseofmaintenance.

Electrical Characteristics

Driver(x) (x)

(x)

(x)

LTS-A2 LTS-B2 LTS-B2

B2-1 (396L)A2-1 (300L/390L) B2-2 (600L/780L)

RD700RD700 RD700

+VDC (x)

VDC End

LTL-8 LTL-8 LTL-8 LTL-8

RD700

L1 (100L)

Driver

Driver Driver

Driver

Wiring Schematic

Driver Output (per Driver) Max. Input Current (per Driver)

Product Compatibility Driver Qty Output

CurrentOutput Voltage 277 VAC 347 VAC 480 VAC Max. Input

Power per DriverMax. Total Input

Power

LTS 4 1050 mA 240-320 VDC 1.39 A 1.11 A 0.80 A 385 W 1540 W

LTS 6 1050 mA 240-320 VDC 1.39 A 1.11 A 0.80 A 385 W 2310 W

LTS/LTL 4 1400 mA 240-320 VDC 1.86 A 1.48 A 1.07 A 514 W 2056 W

LTS/LTL 6 1400 mA 240-320 VDC 1.86 A 1.48 A 1.07 A 514 W 3084 W

Page 14: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

1414 LuxTran™ Tunnel Lighting

“Lighting five lanes of roadway from the wall was a challenge which was met by the [LuxTran] wall fixture provided by Kenall.”

— RandyWalker DirectorofElectricalEngineering JacobsGlobal

Page 15: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

15LuxTran™ Tunnel Lighting

Powerful Performance

PROJECT: TXDOT - Woodall Rodgers TunnelLOCATION: Dallas, TXSPECIFIER: Jacobs Engineering

Read the entire case study at www.kenall.com

Page 16: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

16

The Kenall product shown on this page is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof.

www. kenall.com P: 800-4-Kenall Email: [email protected] 10200 55th Street Kenosha, WI 53144

16 LuxTran™ Tunnel Lighting

LuxTran™ Family of Tunnel Lighting

WFT Series•Corrosionresistant,one-piece,stainlesssteel,seam-weldedhousing•Detachabledoorframewithstainlesssteelspringloadedrelease hingesandstainlesssteellatches• Cleartemperedglasslenssealedtodoorframe• TypelllorIVdistributions• Removablegeartrayforeaseofmaintenance•ULCertifiedIP66perIEC60598

CFT Series•Corrosionresistant,one-piece,stainlesssteelhousing; seam-weldedconstruction•Detachabledoorframewithstainlesssteelspringloadedreleasehingesand stainlesssteellatches• Cleartemperedglasslenssealedtodoorframe• TypeIIIorIVdistributions;forwardthrowoption• Tool-lessaccesstoballastcompartmentforeaseofmaintenance• Externalmountingbracketsforeaseofinstallation•ULCertifiedIP66perIEC60598

IP66

LTD14 Series• Corrosionresistant,one-piece,stainlesssteelhousing; seam-weldedconstruction

• Doorframesecuredtohousingwithstainlesssteelcam

latchesforeaseofmaintenance

• Cleartemperedglasslenssealedtodoorframe

• Symmetricaltransversedistribution

•ULCertifiedIP66perIEC60598

• VibrationtestedtoANSIC136.31•WatertestedtoANSIC136.27-2012(100PSIwatertest)

• NEMA4XRated

IP66

NominalSize 12.5"×21";12"×28"InstallationTypes Surface-CeilingmountLampTypes HPS,MHWattages 100W,150W,250W,400W

IP66

Nominalsize 12"×48"Installationtypes Surface-CeilingorwallmountLamptypes T5,T5HOWattages T528W;T5HO54W

100 PSI

ANSI C136.27

NominalSize 12.5"×21"InstallationTypes Surface-WallmountLampTypes HPS,MHWattages 100W,150W

NEMA4X

Page 17: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

17

The Kenall product shown on this page is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof.

www. kenall.com P: 800-4-Kenall Email: [email protected] 10200 55th Street Kenosha, WI 53144

LuxTran™ Tunnel Lighting

TSQD Series•One-piece,coldrolledsteel,corrosionresistantstainlesssteelor marine-grade,aluminumhousingavailable•One-piecedoorframesealedtohousingwithclosedcellneoprene gasketandfasteners• TypeVdistribution• Externalmountingbracketsforeaseofinstallation•Availableinavarietyoflenstypes• VibrationtestedtoANSIC136.31

LTD2424 Series•Corrosionresistant,one-piece,stainlesssteelhousing; seam-weldedconstruction

•Doorframesecuredtohousingwithstainlesssteelcam latchesforeaseofmaintenance

• Cleartemperedglasslenssealedtodoorframe

• Probeamandcounterbeamasymmetricdistribution

•ULCertifiedIP66perIEC60598

• VibrationtestedANSIC136.31•WatertestedtoANSIC136.27-2012(100PSIwatertest)

•NEMA4XRated

NominalSize 20"×20"InstallationTypes Surface-CeilingmountLampTypes HPS,MH,InductionFluorescentWattages HPS100W,150W,250W;MH250W;IND150W

LuxTran™ Family of Tunnel Lighting

LTD1224 Series •Aluminumalloyhousing;anodizedfinish

• Isolated,externalstainlesssteelhardwarefor corrosionresistance

•One-piece,seam-weldeddoorframewithrotary pulllatchesforeaseofmaintenance

• Cleartemperedglasslens

• Symmetricalaxialdistribution

• VibrationtestedtoANSIC136.31•ULCertifiedIP65perIEC60598

NominalSize 12"×24"InstallationTypes Surface-Wall orceilingmountLampTypes HPSWattages 200W,400W

IP65

100 PSI

ANSI C136.27

NominalSize 24"×24"InstallationTypes Surface-WallorceilingmountLampTypes HPS,MHWattages 100W,250W,400W

IP66 NEMA4X

Page 18: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

18

The Kenall product shown on this page is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof.

www. kenall.com P: 800-4-Kenall Email: [email protected] 10200 55th Street Kenosha, WI 53144

18 LuxTran™ Tunnel Lighting

Testing

Particle Testing Photometric Testing100 PSI Water Test

Sample Ordering Information (Ex: LTSI-A2-C-SM-2-8-390L50K-DCC-CV-316-5KF)Ordering Information

PRODUCT FEATURES:» PoweredbyIntegralDriver

» Suitableforsupplementallightingintransitionzoneswithaceilingorwallorientation

»Opticalconfigurationsdesignedfortunnellightingapplications

» Stainlesssteelstructuralconstructionwithmarine-gradealuminumheatsinks

»ADAcompliantforwallorientations

» 10Yearlimitedproductwarranty

LTSI SERIES

LUXTRAN™

When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. Content of speci�cation sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved.

www.kenall.com P: 800-4-Kenall F: 262-891-9701 10200 55th Street Kenosha, Wisconsin 53144

LTSI-052114

IP66LED

Luminaires for Tunnel Applications

SPECIFICATIONS

CHASSIS:16-gaugeType304orType316stainlesssteelenclosurewithone-piece,seam-weldedconstruction;2Bfinish;passivatedpost-welding.14-gaugedie-formedandweldedmountingpoints;custommountingdetailtotunnelstructureavailable.

HEAT SINKS:Type413marine-gradedie-castaluminum,coatingstowithstandeither1,000houror5,000hoursaltfogtestperASTMB117.Electricallyinsulatedfromstainlesssteelchassis.

DOORFRAME: 16-gaugeType304orType316stainlesssteeldoorframewithone-piece,seam-weldedconstruction;2Bfinish;passivatedpost-welding.Stainlesssteelsafetycablesattachtochassis.Lockablerotarylatches(lockbyothers)constructedofmatchinggradestainlesssteel.

GASKETING: One-pieceextrudedsiliconewithmoldedcorners.

OPTICS: TypeII,Pro-Beam,TypeV-NarrowRoundandTypeVSquareopticaldistributions.Cleartemperedglassorpolycarbonatelens.

ELECTRICAL:Serviceablehigh-brightnessLEDarray.SeeOrderingInformationforcolortemperatureandCRIoptions.70CRIminimum.277-480VAC,50/60Hzsingle-phaseinput;<20%THD,>0.90PF.Minimum90%electricalefficiency.Standard0-10Vdimmingwith0-100%range.EMCcompliantwithFCC47CFRPart15,ClassB.PassesIEC61000-4-4EFTandIEC61000-4-5(Class4)surgeevaluation.

INSTALLATION:Wallorceilingorientation,seeOrderingInformationforselection.Mountinghardwareprovidedbyothers.Conduitentryonbackofluminaire.Ambienttemperatureratingis-40°Cto25°C(40°Con192L/384L/396L).

PHOTOMETRICS: PhotometrytestedtotheIESNALM-79-08standardbyanILAC/ISO17025accreditedlaboratory.Foradditionalphotometricdata,pleasegotowww.kenall.com.

WARRANTY: Limitedten(10)yearwarranty.

LISTINGS: LuminaireiscertifiedtoULStandardsbyIntertekTestingLaboratoryforWetLocation.IP66ratingperIEC60598.RatedtoNEMA4X.Luminaireis3GvibrationtestedperANSIC136.31.PassesANSIC136.27-2012qualificationtest.

PROJECT INFORMATION

Job Name

Fixture Type

Catalog Number

Approved by

ORDERING INFORMATION (Ex: LTSI-B2-C-SM-2-8-396L-50K7-DCC-277-304-5KF)

Model Dist.Type LensType LampPowerMountingDesign

LTSIMounting

3G

Size Con� gurationA2 1×2ModuleArrayB2 2×2ModuleArray

MountingC CeilingW Wall

Mounting Design DetailSM StandardMountingDetail(asshown)CM Custom/Project-SpecificMounting(consultfactory)

Distribution Type2 TypeII2A TypeIIAPB Pro-Beam5N TypeV–NarrowRound5S TypeV–Square

HeatSinkFinish

Lens Type8 .188"TemperedGlassLensG .125"ClearPolycarbonate

Lamp Power - A2Con� guration192L 192WattLED295L 295WattLED300L* 300WattLED390L* 390WattLED400L 400WattLED

Lamp Power - B2Con� guration384L 384WattLED396L* 396WattLED590L 590WattLED600L* 600WattLED780L* 780WattLED800L 800WattLED

Lamp Color40K8 4000K/80CRImin.40K7 4000K/70CRImin.50K7 5000K/70CRImin.57K7 5700K/70CRImin.

Driver TypeDCC DimmingConstantCurrent

Voltage277 277VAC347 347VAC480 480VACCV Custom/Project-SpecificVoltage(consultfactory)

Housing Material304 Type304StainlessSteel316 Type316StainlessSteel

Heat Sink Finish1KF 1,000HourFinish5KF 5,000HourFinish

* AvailablewithTypePBOpticonly

SizeConfiguration HousingMtrlVoltage

DCCDriverType

ADA

LampColor

Whether testing for Ingress Protection or stringent vibration testing, Kenall is equipped, with a state-of-the-art certi� ed safety laboratory, to provide the following testing capabilities:

• Certi� ed for safety testing by Underwriters Laboratory and Intertek Testing Laboratories for Incandescent, Fluorescent and HID Luminaires (UL 1598), LED Luminaires (UL 8750) Hazardous Locations (UL 844, Class I Div II, Class II Div II, Class III), and Emergency Lighting (UL 924).

• Ingress Protection testing (dust and water chambers)

• Highly Accelerated Stress Screening (-50°C to 150°C Environmental Chamber)

• MIL-STD-461F- Conducted electromagnetic interference (EMI)

• 25°C and 40°C thermal testing rooms

• LM-79 accredited photometric laboratory—including a Type C goniophotometer and 2-meter integrating sphere with spectroradiometer—providing credentials for the Department of Energy’s Lighting Facts® listings and DesignLight Consortium® approvals.

• Select Kenall LuxTran™ luminaires are independently tested for vibration, wind and shock according to ANSI standard C136.31 ensuring their ability to withstand the environmental challenges of tunnels.

• Select Kenall LuxTran luminaires are independently tested to ANSI standard C136.27-2012 (100 PSI water test) ensuring their ability to withstand extreme hosedown procedures in tunnels.

• Because it is inherently robust, stainless steel is exempt from the salt spray test.

Page 19: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

19

The Kenall product shown on this page is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof.

www. kenall.com P: 800-4-Kenall Email: [email protected] 10200 55th Street Kenosha, WI 53144

LuxTran™ Tunnel Lighting

Listings, Certifications and WarrantyFixtures designed for use in tunnel applications must satisfy a large number of demanding lighting and environmental requirements. Listings applicable to tunnel luminaires are shown below. Please refer to the product descriptions within each section of this guide to determine specific product listings.

UL/CUL Listed—The UL symbol signifies that Underwriter’s Laboratory (UL) has determined that a manufacturer has demonstrated the ability to produce a product complying with UL’s requirements with respect to specific risk, performance under specific conditions, compliance with regulatory codes and specified standards, or any other conditions as determined by UL.

ETL—Products bearing the ETL Listed mark is determined to have met the minimum requirements of prescribed product safety standards as certified by a Nationally Recognized Testing Laboratory (NTL). The mark also indicates that the manufacturer’s production site conforms to a range of compliance measures and is subject to periodic follow-up inspections to verify continued conformance.

IP65—UL Certified IP65 per IEC 60598 ensures that the enclosure is dust-tight and protected against jet streams of water from any direction without any harmful effects.

IP66—UL Certified IP66 per IEC 60598 ensures that the enclosure is dust tight and protected against water projected in powerful jets without any harmful effects.

ADA Compliant—Although ADA is not specific to lighting, it does impact fixture design by creating standards for wall sconce projection space and hanging light clearance. Section 4.4 of the ADA states that ”objects projecting from walls with their leading edges between 27” and 80” above the finished floor shall protrude no more than 4” into walks, halls, corridors, passageways or aisles.”

3G—Products bearing the 3G listing are independently tested for vibration, wind and shock according to ANSI Standard C136.31 ensuring their ability to withstand the environmental challenges of tunnels.

NEMA 4X—Products bearing the NEMA 4X rating mark are enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water); that provides an additional level of protection against corrosion; and that will be undamaged by the external formation of ice on the enclosure.

100 PSI—Products bearing the 100 PSI listing are independently tested for temperature cycling and 100 PSI water spray according to ANSI Standard C136.27-2012; ensuring the luminaires ability to withstand extreme hosedown procedures in tunnels.

ADA

IP65

C

IP66

10-Year Limited Product WarrantyKenall promises to stand behind our tunnel luminaires. Our commitment to excellence enables us to offer a 10-year limited product warranty. For detailed, product specific warranty information, please visit our website at www.kenall.com.

3G

100 PSI

ANSI C136.27

NEMA4X

Page 20: Challenging Applications Demand Kenall CIE 88 2004, and depend upon the length of the tunnel, the Average Annual Daily Traffi c (AADT), wall refl ectances and whether cyclists are

20

The Kenall product shown on this page is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof.

www. kenall.com P: 800-4-Kenall Email: [email protected] 10200 55th Street Kenosha, WI 53144

20 LuxTran™ Tunnel Lighting

10200 55th Street Kenosha, WI 53144 Tel: 262-891-9700 www.kenall.com

©2015 Kenall Mfg. ̄̄Co. All rights reserved. L10062-011415