Page 1: Channel A - Oxygen, Nitrogen & Carbon Dioxide · Channel A : for the analysis of Hydrogen in the range 0.01 to 0.5% vol. using Argon carrier gas Channel B : for the analysis of Oxygen,

Channel A - Oxygen, Nitrogen & Carbon Dioxide

Channel B - Hydrogen

UK Tel: +44 (0)1353 669916 Fax: +44 (0)1353 669917USA Tel: +1 843 614 3640 Fax: +1 843 614 3642

Germany Tel: +49 (0)561 400 0430 Fax: +49 (0)561 400 0429Email: [email protected] Website: http://www.ellutia.com

Chlorine Analyser

Page 2: Channel A - Oxygen, Nitrogen & Carbon Dioxide · Channel A : for the analysis of Hydrogen in the range 0.01 to 0.5% vol. using Argon carrier gas Channel B : for the analysis of Oxygen,

The Problem

The production of bleach requires Chlorine, which is manufactured by the process of electrolysis. It is important to analyse the quality of the Chlorine gas to ensure that the electrolysis process is effi cient with respect to time, therefore not wasting electricity and to ensure there are no leaks between the membranes.

By analysing the impurities Hydrogen, Oxygen, Nitrogen and Carbon Dioxide in Chlorine gas will indicate the effi ciency of the process and any leakage.

The Solution

Using our expertise here at Ellutia, we have customised the 200 Series GC by adding Multi Dimensional Chromatographic channels each with a TCD, as follows:

Channel A : for the analysis of Hydrogen in the range 0.01 to 0.5% vol. using Argon carrier gas

Channel B : for the analysis of Oxygen, Nitrogen and Carbon Dioxide in the range 0.01 to 3% vol. using Helium carrier gas.

Special Hastelloy valves, pipework and columns have been installed to reduce corrosion by the sample.

Multi Dimensional Chromatography techniques are employed to ensure the Chlorine matrix gas does not reach the TCD.

With the added heated Naffi on dryer installed in the sample line (to remove as much moisture as possible thus reducing potential corrosion) the analyser can be placed “on-line”.

Online Chlorine Analysis

1/16

” x

0.5m

m id

PE

EK

1/16

” od

PTF

E

12vD

C

1/16

” od

Sta

inle

ss S

teel

Air

In

NV

8Pur

ge In

Pur

ge O

ut

Sam

ple

In

ND

1

12

3 4

56

7

89

10

12

3 4

56

7

89

10

12 3

456

Hyd

roge

n In

Car

rier

Cha

nnel

AM

T1H

CT1

InP

R1

NV

1

NV

4

Str

ipp

er A

Ana

lysi

s A

SL1

Str

ipp

er V

ent

A

NV

3

Byp

ass

A

NV

2

NV

5

Str

ipp

er B

Ana

lysi

s B

Det

ecto

rP

ositi

on

Inje

ctor

Pos

ition

SL2

NV

7

NV

6

Str

ipp

er V

ent

B

Sam

ple

Out

PR

2M

T2H

CT2

OT1

Arg

on In

Car

rier

Cha

nnel

B

PR

3

TCD 2

TCD 1

System Diagram