Channel Power
SCADA SOLUTIONS NOVEMBER 2013
DANNY PARVARY EMEA VOIP & SCADA BUSINESS MANAGER
MOTOROLA SCADA SOLUTIONS
SCADA Station
Programming Tool
Conventional Analog Radios, Trunk Analog radios,
PSTN, TETRA, ASTRO, MOTOTRBO, CANNOPY
GPRS, CDMA, IP Microwave, LAN, Microwave …
SCADA COMPONENTS
• Control Centers • Motorola offering supports all major Control Centers
• Data Gateway • Motorola DG Provides connectivity between the Control center & Communication system
• Communication System • Motorola SCADA offering supports all communications media and networks but its not
limited to Motorola radio systems. Motorola SCADA supports Public and Private communication networks as well.
• Remote Terminal Units (RTUs) • Motorola RTU supports all communications media and networks and extensive set of
industrial and “smart” sensors
• Sensors • Provide connectivity to various processes such as Oil & Gas, Electricity and water
management elements such as pumps, valves, power analyzers, environmental IO and more.
SCADA MAIN APPLICATIONS • Oil and Gas Pipelines • Electricity Distribution • Municipal Water, Waste Water • Public Safety and Security • Early Flood Warning • Irrigation, Water Distribution • Communication Monitoring • Transportation • Environmental Monitoring
OIL & GAS SCADA SYSTEMS
• Remote monitoring and control system • Theft and leakage detection • Remote emergency/fire shout-off • Flow and pressure monitoring • Pollution detection and prevention • Operating efficiency & productivity • Proactive maintenance • Personal safety and security • Cost savings: automatic detection, control and
monitoring • Protect investments
OIL AND NATURAL GAS TRANSPORTATION & STORAGE • Management system to ensure efficient and effective
movement of natural gas and crude oil from producing regions to consumption regions
• Centralized control center to collect, assimilate, and manage data received from monitoring and compressor stations all along the pipe.
• Storage of natural gas into storage facilities • Monitor compressing natural gas to reduce its volume
and push it through the pipe • Metering stations to monitor flow of the natural gas along
interstate pipelines • Valves control (for example if a section of pipe requires
replacement or maintenance)
FLOATING PRODUCTION STORAGE AND OFFLOADING • Control & monitor Offloading
process of Storage and offloading vessels
• Remote operation • Enhance Safety • Economical solution for
small oil fields • Can be moved to a new oil
fields
CATHODIC PROTECTION (CP)
• CP systems are used to protect fuel pipelines, storage tanks; offshore oil platforms and onshore oil well casings
• In some cases • Prevent stress corrosion cracking • More economically viable to protect a pipeline
using galvanic anodes.
EMERGENCY SHUTDOWN SYSTEMS
Single ESD command to all RTUs or selectable RTUs • Shut down of part systems and equipment • Isolate electrical equipment • Prevent escalation of events • Emergency ventilation control • Close fire doors.
FEP
Master Control Centre
RTU
RTU
RTU
CITY GAS SYSTEMS
• Monitor flow/consumption • Leakage Detection • Emergency Shut Down • Increase Public Safety
OIL & GAS DISTRIBUTION - RUSSIA
13
OIL & GAS DISTRIBUTION - RUSSIA
OIL & GAS DISTRIBUTION - SERBIA
WW PARTIAL CUSTOMERS LIST
• GASPROM • TRANSNEFT • CPC • SEOUL CITY GAS • BOTAS • TOTAL • PETROBRASS BRASIL • SHELL OIL • MARAVEN • ARCO OIL AND GAS • CORPUS CHRISTY • KOC • SHELL BRUNEI • ELF • KAZAKHSTAN OIL
• KARACHAGANAK PETROLEUM • MARATHON PETROLEUM • MOBIL OIL • OCCIDENTAL PETRO • PEMEX • PETRONAS • PHILLIPS 66 • CHEVRON • TEXACO • TURKMENISTAN SEIDE • UNION CARBIDE • UNOCAL • BELORUSNEFT
POWER GRID CONTROL
240kV-69 kV Substation Control
69kV-12.8 kV Transformer Control
12.8 kV Load Break Switch Control
AMI AMR 110/240V Meter
reading
12.8 kV Power Generation
110/220/750kV Transmission
Distribution Automation
ACE3600 FOR DA
• Control a range of Switchgears from different vendors • Load Break switches • Circuit breakers-Reclosers
• Vendor independence • Significant cost saving • Simple migration to automation
• Worldwide experience • Large projects • Thousands of RTUs in a system
MOSCAD RTU
Power line switch
POWER DISTRIBUTION AUTOMATION
• The power grid equipped with isolating switches
• These switches are being used to isolate a faulty section in the power grid
• Power can be restore to the majority of the power grid once the faulty link was disconnected
• The MOSCAD RTU monitor and control the switch
• The MOSCAD RTU communicates with the Control Center via radio link
TYPICAL DA INSTALLATION
Mechanical Air Break Switch SF – 6 Switch
24KV - 200A MOTORIZED POLETOP
HUNGARY POLETOP SF-6
SUBSTATION AUTOMATION AND TELEMETRY
WW PARTIAL ELECTRIC CUSTOMERS Europe • FECSA Spain • E.ON Hungary • EDB - Belgrade Power Utility Serbia • Kran & Selije Slovenia • EDA Portugal • ENHER Spain • EDF France • Maribor Slovenia • VCE Czech Republic • JP EP BiH ED TZ Bosnia & Herzegovina • Komunalno Brčko Bosnia & Herzegovina • Elektrokrajina Banjaluka Bosnia &
Herzegovina • EP HZ HB Bosnia & Herzegovina • EFACEC Portugal • Elektrovojvodina Serbia
Middle East & Africa • IEC Israel Electric Co • Cape Town Municipality South Africa • ESKOM South Africa • NEPA Nigeria • SA Electric Company South Africa
Asia Pacific • TPC Taiwan • MEA Metropolitan Electric Authority
Thailand • Horowhenua Energy New Zealand • Hanstar Taiwan • EGAT Thailand • Solaris Australia • AGL Australia • Pacific Power N.S.W Australia
WW PARTIAL ELECTRIC CUSTOMERS Latin America • PQU Brazil • ICE Costa Rica • ELECTROSUL Brazil • CESP Brazil • EPSA Colombia • Siderar Campana Argentina • EPEC Argentina • Transpa Argentina • CEMIG Brazil • Garoto Brazil
• INFRAERO Brazil • ELFEC Bolivia • CFE Mexico • Energia del Sur Peru • Electra Panama • Luz Y Fuerza Mexico • T&Tech Trinidad • S&C Guyana • Empresas Públicas de Medellín Colombia • Compañía de Electricidad de Tulua
Colombia
WW PARTIAL ELECTRIC CUSTOMERS USA & Canada • Boston Edison Massachusetts • Northern States Power (NSP) USA • Cincinnati Gas& Elec. Ohio • Soyland Power USA • Baltimore Gas & Electric Maryland • Jones – Onslow EMC USA • Southern Carolina E. South Carolina • Savannah Electric Georgia • DCR Florida • Baltimore Gas and Electric Maryland • GPU Energy Pennsylvania & New
Jersey • Dominion Virginia Power • Silicon Power Corporation Pennsylvania • Rochester Gas and Electric NY • Entergy Louisiana
• Georgia System Operations Center • Alabama Electric Cooperative • Kanata Hydro Quebec Canada
India • RSWM Ltd, Rajasthan India • AD Hydro Power India • Bajura Sub-Stations India • Malana Hydro Power India • Ambuja Cement India • Hindalco India • JayPee Power India • Rajwest Power India • Uttarakhand Jal Vidyut Nigam Ltd
India
WATER CONTROL MANAGEMENT APPLICATIONS
FIRE EXTINGUISHING SYSTEM
• Suit flammable or explosive chemical circumstance, airport, oil area, oil transport wharf, shipyard etc.
• Remote Control of water/foam splinters and canons via • Control Center • Ruggedized suitcases
• Monitor water & foam valves • Control water & foam pumps • Automated splinters/canons
sequence upon emergency situation
AIRPORT CONTROL TOWER APPLICATIONS
TETRA
Control Tower
Braking Cables
Traffic Lights & Signs
End of Runway
Safety Nets
Mobile Control Tower
Sirens
M
Runway lights,
M M
M
M
M
Flickers & Papi Landing strip lights,
M
Approach Lane lights
M CCR Tower
Indicators
M
Navigation Aids M
Signaling lights
= ACE3600 M
AIRPORT CONTROL TOWER • Runway
• Safety nets • Breaking cables • Landing strip lights
• Approach lanes lights and navigation aids
• Traffic lights and Control Tower indicators
• Sirens (Emergency, Alerts, Public annunciation, etc).
• “Vehicle on Runway” alert • Special signaling lights • Mobile Control Tower
workstation
MARINE NAVIGATION SYSTEM
SIREN SOLUTIONS POWER & PETROCHEMICAL SITES
SIREN SOLUTION NATIONAL DISASTER MANAGEMENT SYSTEM
NDMA to identify the exact location of a potential hazards incidents and incorporates centrally-controlled sirens to alert local residents and plant personnel of any impending danger.
RTUs • ACE3600 • MOSCAD-M
NEW PRODUCT PORTFOLIO
FEPs • IP Gateway (new)
• MOPC (SW)
• MCPM/API (SW)
• Accessories • ACT
NEW
NEW NEW
ACE3600 RTU – MODULAR CONFIGURATION
Housing & Chassis
Frames
I/O Modules
CPU
Power Supply
Radios
Software
MOTOROLA RTUS – ACE3600
Multiple Comm. Options - Digital radios VHF / UHF - Analog radios VHF / UHF - Digital trunking - MOTOTRBO - Data radios, MAS - GSM/GPRS/CDMA/HSPA - Wi-Fi / Wi-Max - Wire line - PSTN - Microwave - Fiber Optics
Communication with Field instruments
Command Monitoring
COVERAGE EXTENSION WITHOUT MOTOTRBO REPEATER
36
SCADA Station
Comm. System (TETRA/MOTOTRBO/ASTRO/Canopy/More)
ACE3600
ACE3600
ACE3600 (Out of Range)
Communication Node
Metering concentrator
ACE3600
Metering concentrator
. . .
Electric Meters
Conventional Radio
Metering concentrator
Conventional Radio Comm. System
Base Station
Base Station
Conventional Radio
Microwave
Metering concentrator
Metering concentrator
ACE3600
ACE3600
37
Pushbuttons
Plug-In 1 Port (optional)
Plug-In 2 Port (optional)
Serial 1 Port (RS-232/RS485) Serial 2 Port (RS-232) Ethernet 1 Port (on CPU 3640 and CPU 3680)
Status LEDs
Communication Ports LEDs
User LEDs
USB Device Port (for Future use)
2 USB Host Ports for MotoTrbo radios)
CPU 3610 CPU3640 CPU3680 Flash memory 16 MB 16 MB 32 MB SDRAM memory: 32 MB 32 MB 128 MB
User Flash: 3 MB 3 MB 19 MB User SDRAM: 10 MB 10 MB 118 MB SRAM Plug-In 4 MB 4 MB 4 MB
CPU3680
CPU PLUG-IN PORT OPTIONS
• Serial Ports • RS232 up to 230 kb/s • RS485 up to 230 kb/s
• Configurable conventional/ Trunk radio modems:
• DPSK 1.2 kb/s, FSK 2.4 kb/s , DFM 4.8 kb/s , Duo-Binary 9.6 kb/s
• Ethernet • 10/100 Mb/s (In Plug-in 1 only) • Ethernet 10 Mb/s
38
COMMUNICATION MEDIA OPTIONS
• Motorola Radio Support: • Mobile two-way radio - CM200, CM140, EM200, GM3188, CDM750 • Portable two way radio - HT 750, GP320, GP328, PRO5150 • Astro – XTL 5000 & XTL2500 (mobile digital and analog trunking), XTS
2500 (portable digital Trunking) • Dimetra – MTM700/800 • MotoTrbo Digital - XPR4350, DM3400, XiR M8220, DGM4100
• 3rd party Radio / MODEM connectivity • 3rd party two way radios • Data radios (MDS, Data radio, etc.) • Dial-up modems • Cellular modems (dial mode & PD, GPRS,CDMA) • Broadband (WLAN, Canopy, iNet900,etc.)
39
MOTOROLA COMMUNICATION SOLUTIONS - UNLIMITED
40
TCP/IP on Ethernet
IP GATEWAY
SCADA Computer
MOSCAD Tool Box
SCADA Computer
RS-232
RS-232 RS-485 RTU
RTU
RTU RTU
RTU
19.2 Kbps RS232
IP Network (Intranet)
MOSCAD toolbox IP)
Ethernet
MDLC over IP RTU
RTU
RTU
RTU Fiber optic
RTU RTU
RTU
Radio
I/O EXPANSION FRAMES & DISTRIBUTED I/O (UP TO 13 I/O EXPANSION FRAMES)
LAN Cables
Expansion Frame #1
Up to 50 m
Power
Up to 50 m
Main Frame
Expansion Frame #n
Power Power
Main Frame Power Supply CPU 3640 LAN Switch
Expansion Frame Power Supply Exp. CPU
ACE3600 RTU REDUNDANCY
PS2 PS1 CPU1 CPU2
4 I/O cards
NEW • Hot/Swap
• Power Supply Redundancy • CPU Redundancy
• < 50msec switch over • Rear onboard 100Mb/s port • IO Expansion rack support • OS data base sync. function • 50x50 cm metal chassis • 19” rack mount installation
RTU & FEP MOTOTRBO DIRECT CONNECTIVITY
CPU3680 CPU4600
Two USB2.0 Host Ports GM3400
MOTOTRBO radio
Inputs, Outputs & Comm. Ports TO MONITOR & CONTROL
USB CABLE
• Supports MOTOTRBO digital radio topologies • Direct Mode (DMO) • Single Repeater • IP Site Connect
• NO Interface box • Dynamic Remote Site
Addressing • Supports GROUP CALL • FULL OSI 7 Layers
implementation • Provides RNDIS Interface • True IP physical port over
USB2.0
NATURAL GAS TURBINE GENERATOR STATION
44
A Good Day A Bad Day
NATIONAL THREAD
• Control system attacks: • Foreign-Based Cyber Attack on Illinois Water Plant? (Nov 2011) • Hacker Breached Texas Water Plant. (Nov 2011) • Stuxnet • Netherlands pumping system - accessed remotely (Feb 2012)
• Possible intruders:
• Countries accompanying military actions (Georgia) / feasibility tests
• Security experts investigations & demos (Texas, Netherlands)
• Organized crime
45
PAGE 46
One example of the challenges presented was the recent disclosure of a SCADA system compromise, which was responsible for controlling a local government’s municipal water supply. This example highlights the need to focus cyber security efforts and the importance of critical infrastructure. SCADA security is an emerging issue, which can no longer be ignored. The U.S. Department of Homeland Security Control Systems Security Program, Idaho National Laboratory, Chief Information Security Officer of New York State, and the SANS Institute have established an initiative to bring public and private sector entities together to improve the security of control systems. The goal is for private and public asset owners and regulators to come together and adopt procurement language that will help ensure security integration in control systems. The Cyber Security Procurement Language Project Workgroup comprises 242 public and private sector entities from around the world representing asset owners, operators, and regulators. In addition, over 20 vendors participate in a working group to assist in reviewing and producing the procurement language.
WHAT ARE CONTROL SYSTEMS? Supervisory Control and Data Acquisition (SCADA), Process Control System (PCS), Distributed Control System (DCS), etc. generally refer to the systems which control, monitor, and manage the nation’s critical infrastructures such as electric power generators, subway systems, dams, telecommunication systems, natural gas pipelines, and many others.
http://www.us-cert.gov/control_systems/pdf/FINAL-Procurement_Language_Rev4_100809.pdf
MOTOROLA SCADA BUSINESS Collaboration with
• US Department of Homeland Security
• US Technical Support Work Group TSWG addresses a technical specialty to meet requirements across the four pillars of combating terrorism
• Antiterrorism • Counterterrorism • Intelligence support • Consequence management.
• Other National Information Security Agencies
47
MSI IS PIONEER IN SCADA SECURITY • Most vendors are in evaluation process of needs • WindRiver & McAfee embedded white-listing is
in definition stage • There are many IT security experts but very little
for non IP world!
Motorola SECURED ACE3600 is the first FULLY secured RTU/PLC to hit the market
48
Secured ACE IP Gateway / FIU
Secured ACE3600 Authentication Server
SCADA Workstation / Server
SecuredACE3600
SecuredACE3600
Secured Admin STS Tool
Secured Technician STS Tool
CONTROL CENTER
SecuredACE3600
NEW
SECURITY RELEASED
SECURED MDLC COMMUNICATION
NETWORK
ACE3600 SECURE PRODUCTS
• Secured ACE 3600 RTU • Secured ACE IP Gateway • ACE 3600 Users Authentication Server • Secured configuration & management tools
(STS)
50
SECURITY COMPONENTS
• MDLC Encryption • Users authentication • Users permissions • File encryption • Security logs • White-listing • Policy enforcement • Communication ports control • Default passwords avoidance • Limit access protocols
MOSCAD-M RTU MAIN FEATURES
CONTROLLED DEVICES
SUPERVISED DEVICES
DI, AI
DO, AO
RS-232/RS-485 (MDLC)
OR External Radio
• MOSCAD Low Cost RTU • Member of the MOSCAD/ACE3600 family • Basic I/Os - 12DI, 4 Relay DO, 4 FET DO • Optional expansion I/O board – 3DI, 4AI, 1AO • Power Management Features (PMF) • Sleep Mode Operation @ 5ma • Programmable Wakeup Events • Three communication ports
• One RS485/RS232 Port • One RS-232 Ports • One RS-232 or Radio
• LED display - functional/diagnostic • DNP3.0 and other protocols • Programmable by ‘C’ Toolkit • Indoor Housing (Wall/DIN rail mounting)
RS-232/RS-485 “SMART”
DEVICES
53
Direct DI LED + Train DI
Expansion Board
AO AI
Radio DO ML
FPGA Clock Monitor
9 - 30 V V Keep - Alive
PS_VNORMAL (SW)
PS_MAIN
PS_FPGA (SW)
V In Monitor (SW)
PS_RADIO (SW)
PS_AI_FLOATING
PS_AO_FLOATING
PF2
PG1
PC6
PF0
PB3
PC3
PK7
Uart 2 Uart 1
PF5
PF6
MOSCAD-M RTU PMF
SCADA SW ELECTRICITY
54
SCADA SW WATER MANAGEMENT
55
SCADA SW OIL & GAS
56
COMPLETE DEMO SCADA SOLUTION LAUNCH PACK
PROMOTIONAL PACKAGE AVAILABLE
PLEASE CONTACT YOUR REGIONAL SALES MANAGER or myself at [email protected]
• Two MOSCAD-M RTUs - F4586 • ACE3600 FEP - F7509 • STS - System Tools Suite - F7500 • MOSCAD-M Toolbox - F4560 • MOSCAD-M Easy Configurator • ACE3600 FEP application • WIZCON SCADA demo application • WIZCON SCADA demo version
LOW COST RTU – HW TBD*
58
DIN Rail
Back Up Battery
Main Power
PS CPU IO1 IO2
Eth
C A N
Serial
USB
Plug IN
12-24V IN
LED
’s
IO’s
SD card
C A N
LED
’s
IO’s
C A N
C A N
LED
’s
IO’s
C A N
C A N
CAN + PWR BUS
PWR IN
Bat IN/OUT
12V OUT
LED’s
C A N
C A N
AUX Out
CPU Module • Small size • Low power capable
(Sleep mode) • High bandwidth capable
(Broadband ready) • Few general purpose I/O
(Wakeup on I/O) • Standard BUS Interfaces • Strong Security built in • Low cost
I/O Modules: • Small size 10x12x3 cm • Low power capable
(Sleep mode) • Small Variety of I/O options • Low cost
LOW COST RTU – SW TBD*
• OS: Linux (Including Java VM)
• Built-In Security (i.e. Authorization, Authentication, Encryption..)
• Built-In Protocols (i.e. SNMP, SSH, SFTP, HTTPS, MDLC …)
• Built-In Interfaces (i.e. Management - STS, SNMP MIB, …)
• Built-In Communication (i.e. Ethernet, USB, CAN, Serial)
• Built-In Database (i.e. Data Tables,…)
• Optional Communication (i.e. WiFi, LTE,…)
• Application Framework (i.e. VAR Application framework..)
• Application specific protocols (i.e. MODBUS,…)
59
SHOULD YOU HAVE ANY QUIERY PLEASE CONTACT YOUR REGIONAL SALES MANAGER OR DANNY PARVARY AT
mailto:[email protected]