Chapter 12
Mission-Specific Competencies: Product
Control
![Page 2: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/2.jpg)
Objectives: Operations Level Responders Assigned Mission-Specific Responsibilities (1 of 3)
• Describe and identify the control options available to operations levels responders.(NFPA 6.6.3.1, p. 254–255)
• Describe and identify the control options available for flammable liquid and flammable gas incidents. (NFPA 6.5.2.1(1)(2), p. 254–255)
• Describe the purpose, equipment, and precautions associated with control options.(NFPA 6.6.3.1, 6.6.3.2, p. 255–267)
![Page 3: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/3.jpg)
Objectives: Operations Level Responders Assigned Mission-Specific Responsibilities (2 of 3)
• Describe the applicability and characteristics of aqueous film-forming foam, alcohol-resistant concentrates, fluoroprotein foams, protein foams, and high-expansion foams. (NFPA 6.6.4.1(1)(2), p. 265)
• Identify the location and describe the use of emergency remote shut-off devices on MC 306/DOT 406, MC 307/DOT 407, and MC 331 cargo tanks containing flammable liquids or gases. (NFPA 6.6.4.1(4)(5), p. 262–263)
![Page 4: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/4.jpg)
Objectives: Operations Level Responders Assigned Mission-Specific Responsibilities (3 of 3)
• Describe the recovery phase, and the transition from emergency to clean-up.(NFPA 6.6.4.2, p. 267–268)
![Page 5: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/5.jpg)
Introduction (1 of 3)
• Confinement– Process of attempting to keep hazardous
material within immediate area of release– Damming or diking material, or suppressing
vapor with appropriate type of foam
![Page 6: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/6.jpg)
Introduction (2 of 3)
• Containment– Actions that stop the hazardous material from
leaking or escaping container– Patching or plugging a breached container– Righting an overturned container to stop slow
leak
![Page 7: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/7.jpg)
Introduction (3 of 3)
• When considering control option, evaluate:– Maximum quantity of material that can be
released– Likely duration of incident without intervention
![Page 8: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/8.jpg)
Control Options
• Sometimes no action is the safest course of action. – The situation may be extreme. – Responders cannot be properly protected. – Product will evaporate quickly, cool down, or
solidify.
![Page 9: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/9.jpg)
Absorption (1 of 2)
• Spongy material (e.g., soil or loose absorbents) or specially designed spill pads are used to soak up a liquid hazardous material.
• Contaminated mixture of absorbent material and chemicals are collected and disposed of together.
• Effective only on flat surfaces
![Page 10: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/10.jpg)
Absorption (2 of 2)
• Process does not change chemical properties of substance; only collects substance for containment
• Challenging because personnel must be in close proximity to spilled material
• Adding material to a spilled product adds volume to the spill.
![Page 11: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/11.jpg)
Adsorption
• Contaminant adheres to surface of added material (e.g., silica or activated carbon) rather than combining with it.
• This process can generate heat, which should be considered.
![Page 12: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/12.jpg)
Damming• Used when liquid is flowing in a natural channel or
depression and its progress can be stopped by blocking the channel
![Page 13: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/13.jpg)
Complete Dam
• Placed across a small stream or ditch to completely stop flow of material through channel
• Used only in areas where stream or ditch is dry and amount of material needed to be controlled is small
![Page 14: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/14.jpg)
Overflow Dam• Used to contain materials heavier than
water• Dam base is built up to level that holds
back flow of water.• PVC pipe or hard suction hose is installed
at a slight angle to allow water to flow “over” the released liquid.
• Heavier material is trapped at low level at base of dam.
![Page 15: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/15.jpg)
Underflow Dam• Used to contain materials lighter than
water• Piping is installed near bottom of dam so
water flows “under” dam.• Materials floating on the water accumulate
at top of dam area.• Must have sufficient pipes and hoses to
allow enough water to flow past dam without overflowing over top of dam
![Page 16: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/16.jpg)
Diking
• Placement of selected material, such as sand, dirt, loose absorbent, or concrete, to form a barrier that will keep a liquid hazardous material from entering an unwanted area or to hold material in specific location
• Material used to control hazard must not react adversely with spilled material.
![Page 17: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/17.jpg)
Dilution
• Addition of water or another substance to weaken the strength or concentration of hazardous material (typically a corrosive)
• Used only when identity and properties of hazardous material are known
• Water applied to dilute hazardous material may simply increase total volume.
• Take extreme caution.
![Page 18: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/18.jpg)
Diversion• To redirect flow of liquid away from an
endangered area to an area where it will have less impact
• Existing barriers may be effective way to divert liquids away from storm drains or other unwanted destinations.
• Dirt berms, spill booms, plastic tarps filled with sand, dirt, or clay
• Not as permanent as a dike; constructed quickly
![Page 19: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/19.jpg)
Retention
• Creating a defined area to hold hazardous materials
• Material is held until clean-up contractor can recover it.
• Sometimes, diversion technique is required to guide spilled liquid into retention basin.
![Page 20: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/20.jpg)
Remote Valve Shut-Off (1 of 3)
• Many chemical processes, and many piped systems that carry chemicals, provide a way to remotely shut down a system or isolate a leaking fitting or valve.
• Many types of cargo tanks have emergency remote shut-off valves.
Courtesy of Glen Rudner
![Page 21: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/21.jpg)
Remote Valve Shut-Off (2 of 3)
• MC306/DOT406 cargo tanks carry flammable and combustible liquids and Class B poisons.– Remote shut-off valves located at front of
cargo tank on driver’s side or rear of cargo tank on passenger side
• MC-307/DOT-407 cargo tanks carry chemicals transported at low pressure.– Outfitted with many safety features similar to
those found on MC306/DOT406 cargo tanks
![Page 22: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/22.jpg)
Remote Valve Shut-Off (3 of 3)
• MC-331 cargo tanks carry compressed liquefied gases. – Remote shut-off
valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents
Courtesy of Rob Schnepp
![Page 23: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/23.jpg)
Vapor Dispersion (1 of 2)
• Lowering concentration of vapors by spreading vapors out
• Vapors can be dispersed with:– Hose streams set on fog patterns– Large displacement fans– Other types of mechanical ventilation found in
fixed hazardous materials handling systems
![Page 24: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/24.jpg)
Vapor Dispersion (2 of 2)
• Vapor dispersion with fans or fog stream should be attempted only after hazardous material is safely identified and in weather conditions that will promote diversion away from populated areas.
![Page 25: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/25.jpg)
Vapor Suppression• Controlling fumes or vapors that are given
off by certain materials, particularly flammable liquids, in an attempt to prevent their ignition
• Hazardous material covered with foam or other material or temperature of material is reduced.
• Responders must choose foam designed to work in certain situations.
![Page 26: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/26.jpg)
Aqueous Film-Forming Foam• Used at 1%, 3%, or 6% concentration• Designed to form blanket over spilled
flammable liquids to suppress vapors or on actively burning pools of flammable liquids
• Usually biodegradable• Applied by in-line foam eductors, foam
sprinkler systems, and portable or fixed foam proportioning systems
![Page 27: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/27.jpg)
Alcohol-Resistant Concentrates
• Properties similar to AFFF, but formulated so that alcohols and other polar solvents will not dissolve foam
![Page 28: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/28.jpg)
Fluoroprotein Foam
• Protein products mixed with synthetic fluorinated surfactants.
• Used on fires or spills involving gasoline, oil, or similar products
• Rapidly spread over fuel, ensuring fire knockdown and vapor suppression
• Resistant to polar solvents such as alcohols, ketones, and ethers
![Page 29: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/29.jpg)
Protein Foam
• Made from hydrolyzed proteins along with stabilizers and preservatives
• Stable and have good expansion properties
• Resistant to reignition when used on Class B fires or spills involving nonpolar substances
![Page 30: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/30.jpg)
High-Expansion Foam
• Used when large volumes of foam required for spills or fires in warehouses, tank farms, and hazardous waste facilities
• Expansion accomplished by pumping large volumes of air through small screen coated with foam solution.
• “Dry” foam—due to large amount of air in the foam
![Page 31: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/31.jpg)
Foam Application (1 of 3)
• Foam concentrates (other than high-expansion foam) should be gently applied or bounced off another adjacent object so they flow down across liquid and do not directly upset burning surface.
![Page 32: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/32.jpg)
Foam Application (2 of 3)
• Rain-down method – Directing stream in air over material and
letting foam gently fall onto surface of liquid• Roll-in method
– Bouncing stream directly into front of spill area and allowing it to gently push forward into the pool
![Page 33: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/33.jpg)
Foam Application (3 of 3)
• Bounce-off method – Using object to deflect foam stream and
letting it flow down onto burning surface
![Page 34: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/34.jpg)
Recovery Phase (1 of 3)
• When imminent danger to people, property, and environment has passed or is controlled, and clean-up begins
• Local, state, and federal agencies involved– Cleaning up site– Determining responsible party– Implementing cost-recovery methods
![Page 35: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/35.jpg)
Recovery Phase (2 of 3)
• Can go on for days, weeks, or even months and may require large amounts of resources and equipment
• Sometimes clear transition between emergency phase and clean-up phase– Decision made by incident commander
![Page 36: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/36.jpg)
Recovery Phase (3 of 3)
• Other times, initial responders perform both emergency response and clean-up.
• Includes completion of records necessary for documenting incident
Courtesy of Captain David Jackson, Saginaw Township Fire Department
![Page 37: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/37.jpg)
Summary (1 of 4)
• When considering a control option, a variety of factors must be evaluated, such as the maximum quantity of material that can be released and the likely duration of the incident if no intervention is made.
• Sometimes the situation is so extreme, or the proposed action is so risky, that it may be prudent to create a safe perimeter and let the problem stabilize on its own.
![Page 38: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/38.jpg)
Summary (2 of 4)
• Control techniques or options generally aim to contain, redirect, or lower the concentration of the hazardous material involved and/or to prevent the ignition of flammable liquids or gases.
• Responders can employ a variety of product-control options, such as absorption, diversion, damming, diking, or isolating a leak with remote shut-off valves.
![Page 39: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/39.jpg)
Summary (3 of 4)
• Special foams can help both in vapor suppression actions and in extinguishment of fires associated with flammable liquid releases.
• Responders should be aware of the location of emergency shut-off valves at fixed facilities and on the various types of cargo tanks typically found in their response area.
![Page 40: Chapter 12 · 2019. 4. 2. · gases. – Remote shut-off valves located at both ends of tank, internal shut-off valves, rotary gauge depicting product pressure, and top-mounted vents](https://reader033.vdocuments.net/reader033/viewer/2022060913/60a73ddb41fcf91f902f875e/html5/thumbnails/40.jpg)
Summary (4 of 4)
• The recovery phase may last for days or months and aims to return the exposure area to its original condition and return the facility or mode of transportation to the responsible party.