chapter 4 motorola r56!09!01 05

Upload: gomozalipan

Post on 03-Jun-2018

311 views

Category:

Documents


6 download

TRANSCRIPT

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    1/100

    CHAPTER

    4EXTERNALGROUNDING(EARTHING)

    This chapter provides requirements and guidelines for designing and installing the external

    grounding (earthing) electrode system at a communications site.

    This chapter provides information on the following topics:

    Lightning Activity and Exposure on page 4-3

    Common Grounding (Earthing) on page 4-5

    Grounding (Earthing) Electrode System Component and Installation Requirements on

    page 4-7

    Dissimilar Metals and Corrosion Control on page 4-34

    Bonding to the External Grounding (Earthing) Electrode System on page 4-40

    Minimum Site Grounding (Earthing) Requirements on page 4-44

    Grounding (Earthing) Roof-Mounted Antenna Masts and Metal Support Structures onpage 4-74

    Grounding (Earthing) Rooftop Mounted Tower Structures on page 4-79

    Special Grounding (Earthing) Applications on page 4-81

    Special Grounding (Earthing) Situations on page 4-88

    NOTE: Throughout this chapter the terms groundingand earthingare used synonymously.

    4.1 INTRODUCTION

    The requirements and guidelines in this chapter are derived from a compilation of local and

    national codes, widely accepted industry codes and standards, and good engineering practices.

    Such codes and standards are from, but not limited to, the following standards organizations:

    Alliance for Telecommunications Industry Solutions (ATIS)

    American National Standards Institute (ANSI)

    Australian Standards(AS)

    British Standards Institution (BS)

    International Association of Electrical Inspectors (IAEI)

    International Electrotechnical Commission (IEC)

    Institute of Electrical and Electronics Engineers (IEEE) National Fire Protection Association (NFPA)

    Telecommunications Industry Association (TIA)

    Underwriters Laboratories (UL)

    United States Department of Defence (DoD)

    United States Federal Aviation Administration (FAA)

    United States National Weather Service

    68P81089E50-B 9/1/05 4-1

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    2/100

    INTRODUCTION CHAPTER4: EXTERNALGROUNDING(EARTHING)

    References to the specific industry codes and standards on which this chapter is based are provided

    throughout. The requirements and guidelines in this chapter are provided to enhance personnel safety

    and equipment reliability.

    Safety of personnel and protection of sensitive electronic equipment from ground faults, lightning,

    ground potential rise, electrical surges, and power quality anomalies is of utmost importance at any

    communications site. Though unexpected electrical events like lightning strikes and power surges

    cannot be prevented, this chapter provides design and installation information on communications site

    grounding electrode systems that may help minimize damage caused by these events.

    CAUTION

    Grounding (earthing) and bonding alone are not enough to adequately protect a

    communications site. Transient voltage surge suppression (TVSS) techniques, usingappropriate surge protection devices (SPD), shall be incorporated at a communications

    site in order to provide an adequate level of protection. See Chapter 7, SurgeProtective Devices, for details and requirements.

    A grounding electrode system shallhave low electrical impedance, with conductors large enough to

    withstand high fault currents. The lower the grounding electrode system impedance, the more

    effectively the grounding electrode system can dissipate high-energy impulses into the earth.

    WARNING

    The AC power system ground shall be sized appropriately for the electrical service and

    shall be approved by the local authority having jurisdiction.

    All site development and equipment installation work shallcomply with all applicable codes in use by

    the authority having jurisdiction. Grounding systems shallbe installed in a neat and workmanlike

    manner (NFPA 70-2005, Article 110.12 and NFPA 780-2004, section 1.4). Where conflicting, the more

    stringent standard should be followed. Government and local codes shalltake precedence over the

    requirements of this manual.

    Unusual site conditions may require additional effort to achieve an effectively bonded and grounded

    (earthed) site. See Special Grounding (Earthing) Situations on page 4-88in these instances.

    Consultation with Motorola Engineering or an engineering firm specializing in grounding electrode

    system design is recommended.

    Some of the benefits of a properly designed and installed low-impedance grounding electrode system

    are described below (See ANSI T1.333-2001, section 4; ANSI T1.334-2002, section 5.1; BS

    7430:1998; IEC 60364-1; IEEE STD 142-1991, section 1.3; IEEE STD 1100-1999, section 3.3.1; and

    NFPA 70-2005, Article 250.4 for additional information): To help limit the voltage caused by accidental contact of the site AC supply conductors with

    conductors of higher voltage.

    To help dissipate electrical surges and faults, to minimize the chances of injury from grounding

    system potential differences.

    To help limit the voltages caused by lightning.

    To help maintain a low potential difference between exposed metallic objects.

    4-2 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    3/100

    STANDARDS ANDGUIDELINES FORCOMMUNICATIONSITES LIGHTNINGACTIVITY ANDEXPOSURE

    To stabilize the AC voltage relative to the earth under normal conditions.

    To contribute to reliable equipment operation.

    To provide a common signal reference ground.

    4.2 LIGHTNINGACTIVITY ANDEXPOSURECommunications facilities shall be defined as exposed to lightning unless thunderstorm activity in the

    area is an average of five thunderstorm-days per year or fewer and soil resistivity at the site is less than

    10,000 ohm-centimeters (-cm). The soil resistivity shallbe measured as described in ANSI/IEEE STD

    81. (ANSI T1.313-2003, section 5.1.1) See Appendix B for soil resistivity measurement methods.

    Figure 4-1and Figure 4-2are maps representing typical lightning activity throughout the world. These

    figures are for general informational and educational purposes only and are not indicative of current or

    future lightning activity. The average amount of lightning that occurs in any given area varies

    significantly from year to year.

    ASIANORTH

    AMERICA

    SOUTH

    AMERICA

    AFRICA

    EUROPE

    AUSTRALIA

    0 12 45 910 1920 3940 5960 7980 99100 139140 200+

    FIGURE 4-1 LIGHTNINGACTIVITY, THUNDERSTORMDAYSPERYEAR

    68P81089E50-B 9/1/05 4-3

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    4/100

    LIGHTNINGACTIVITY ANDEXPOSURE CHAPTER4: EXTERNALGROUNDING(EARTHING)

    FIGURE 4-2 LIGHTNINGACTIVITY, FLASHDENSITY(FLASHES PERSQUAREKILOMETER PERYEAR)

    Table 4-1provides a relationship between thunderstorm days per year and lightning flashes per square

    kilometer per year (BS 6651:1999, table 6).

    TABLE 4-1 RELATIONSHIPBETWEENTHUNDERSTORMDAYS PERYEAR ANDLIGHTNINGFLASHESPERSQUAREKILOMETER PERYEAR

    Thunderstorm

    days per year

    Flashes per square kilometer

    per year

    Flashes per square mile per

    year

    Mean Limits Mean Limits

    5 0.2 0.1 to 0.5 0.5 0.25 to 1.35

    10 0.5 0.15 to 1 1.29 0.38 to 2.59

    20 1.1 0.3 to 3 2.84 0.77 to 7.77

    30 1.9 0.6 to 5 4.92 1.55 to 13

    40 2.8 0.8 to 8 7.25 2 to 20.7

    50 3.7 1.2 to 10 9.58 3.1 to 25.9

    60 4.7 1.8 to 12 12.17 4.66 to 31

    80 6.9 3 to 17 17.87 7.8 to 44

    100 9.2 4 to 20 23.82 10.36 to 51.8

    NOTE: Information obtained from BS 6651:1999, Table 6.

    4-4 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    5/100

    STANDARDS ANDGUIDELINES FORCOMMUNICATIONSITES COMMONGROUNDING(EARTHING

    Communications facilities located at elevations significantly above the average elevation of the

    surrounding terrain (such as hilltops, fire towers, airport control towers, and high-rise buildings) shall

    be considered exposed to lightning regardless of thunderstorm activity and soil resistivity. (ANSI

    T1.313-2003, section 5.1.1.)

    Communications facilities with a tower shallbe considered as exposed, regardless of thunderstorm

    activity and soil resistivity. By their very construction, radio antennas/towers are considered exposed to

    the possible damaging effects of lightning. Tall structures, such as towers, buildings and antenna masts,

    provide a favorable discharge point for lightning strokes. (ANSI T1.313-2003, section 5.2.3.)

    Some communications facilities may be classified as unexposed if the building and tower are within the

    zone of protection of a higher structure. Only a qualified engineer should determine if the

    communications facility is unexposed. The following standards can be used by the engineer to help

    determine if the communications facility is unexposed: BS 6651:1999, IEC 61024-1-2, NFPA 780

    2004, or other applicable standard in effect and recognized by the local authority having jurisdiction.

    4.3 COMMONGROUNDING(EARTHING)

    At a communications site, there shallbe only one grounding (earthing) electrode system. For example,

    the AC power system ground, communications tower ground, lightning protection system ground,

    telephone system ground, exposed structural building steel, underground metallic piping that enters the

    facility, and any other existing grounding electrode system shallbe bonded together to form a single

    grounding electrode system (ANSI T1.313-2003; ANSI T1.333-2001; ANSI T1.334-2002; IEC 61024

    1-2, section 2.4.4; IEEE STD 1100-1999; NFPA 70-2005, Articles 250.58, 250.104, 250.106, 800.100,

    810.21, and 820.100; and NFPA 780-2004, Section 4.14).

    All grounding media in or on a structure shallbe interconnected to provide a common ground potential.

    This shallinclude, but is not limited to, the AC power system ground, communications tower ground,

    lightning protection system ground, telephone system ground, exposed structural building steel, and

    underground metallic piping systems. Underground metallic piping systems typically include water

    service, well castings located within 7.6 m (25 ft.) of the structure, gas piping, underground conduits,underground liquefied petroleum gas piping systems, and so on. Interconnection to a gas line shallbe

    made on the customer's side of the meter (NFPA 780-2004, Section 4.14.1.3).

    68P81089E50-B 9/1/05 4-5

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    6/100

    COMMONGROUNDING(EARTHING) CHAPTER4: EXTERNALGROUNDING(EARTHING)

    TO SUPPLY

    TRANSFORMER

    SERVICE

    EQUIPMENT

    BUILDING

    STEEL

    GROUNDED

    CONDUCTOR

    GROUND ROD

    CONCRETE

    ENCASED

    ELECTRODE

    METAL

    WATER

    PIPE

    GROUND RING

    TO LIGHTNING

    PROTECTION SYSTEM

    FIGURE 4-3 COMMONGROUNDINGEXAMPLE

    4-6 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    7/100

    STANDARDS ANDGUIDELINES FORCOMMUNICATIONSITES GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATION

    REQUIREMENTS

    4.4 GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENTANDINSTALLATIONREQUIREMENTS

    WARNING

    To prevent accidental damage to underground utilities, always have the local utilitycompany or utility locator service locate the underground utilities before excavating or

    digging at a site.

    The external grounding (earthing) electrode system may consist of, but is not limited to, the following

    components, shown in Figure 4-4:

    Ground rods or other grounding electrodes

    Concrete encased electrode

    Building or shelter ground ring

    Tower ground ring

    Grounding conductors

    Radial grounding conductors

    Guy wire grounding conductors (guyed towers only)

    Tower ground bus bar

    External ground bus bar

    Fence grounding conductors

    68P81089E50-B 9/1/05 4-7

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    8/100

    A: Grounding Radials

    B. Tower Ground Bus Bar and Down Conductor

    C. Generator Grounding Conductor

    D. Buried Fuel Tank Grounding Conductor

    E. External Ground Bus Bar

    F. Shelter Ground Ring

    G. Fence Grounding Conductor

    H. Ground Ring Bonding Conductors (2 minimum)I. Tower Ground Ring

    J. Earthing Electrodes (Ground Rods)

    GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATIONREQUIREMENTS CHAPTER4: EXTERNALGROUNDING(EARTHING)

    FIGURE 4-4 TYPICALEXTERNALGROUNDINGELECTRODESYSTEM

    4-8 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    9/100

    STANDARDS ANDGUIDELINES FORCOMMUNICATIONSITES GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATION

    REQUIREMENTS

    4.4.1 GROUNDING(EARTHING) ELECTRODES

    Grounding (earthing) electrodes are the conducting elements used to connect electrical systems and/or

    equipment to the earth. The grounding electrodes are placed into the earth to maintain electrical

    equipment at the potential of the earth. Grounding electrodes may be ground rods, metal plates, concrete

    encased electrodes, ground rings, electrolytic ground rods, the metal frame of building or structure, and

    metal underground water pipes (NFPA 70-2005, Article 250 (III)).

    NOTE: Metallic underground gas piping shall notbe used as a grounding electrode (NFPA 70-2005, Article250.52), but shallbe bonded upstream from the equipment shutoff valve to the grounding electrode

    system as required by NFPA 70-2005, Article 250.104 and NFPA 780-2004, section 4.14.1.3.

    4.4.1.1 GROUNDING(EARTHING) ELECTRODERESISTANCECHARACTERISTICS ANDSPHERE OFINFLUENCE

    Around a grounding (earthing) electrode, such as a driven ground rod, the resistance of the soil is the

    sum of the series resistances of virtual concentric shells of earth, located progressively outward from the

    rod. The shell nearest the ground rod has the smallest circumferential area, or cross section, so it has the

    highest resistance. Successive outward shells have progressively larger areas, therefore, progressively

    lower resistances. (IEEE STD 142-1991, section 4.11 and MIL-HDBK-419A).

    Rod Length

    Concentric Shells

    2X Rod Length

    FIGURE 4-5 GROUNDINGELECTRODESPHERE OFINFLUENCE

    The effect of the concentric shells is that it takes a finite amount of earth for a ground rod to fully realize

    its resistance value. This finite amount of earth is commonly known as the ground rod's sphere of

    influence. The sphere of influence for a ground rod is commonly thought of to be a radius around the

    ground rod equal to its length; the ground rod achieves approximately 94% of its resistance value at this

    radius (100% is achieved at approximately 2.5 times the rod length) (IEEE STD 142-1991, section 4.1).

    See Figure 4-5.

    68P81089E50-B 9/1/05 4-9

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    10/100

    GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATIONREQUIREMENTS CHAPTER4: EXTERNALGROUNDING(EARTHING)

    Optimum Spacing2X Rod Length

    2X Rod Length

    FIGURE 4-6 MINIMUMGROUNDINGELECTRODESPACING FORMAXIMUMEFFECTIVITY

    Table 4-2provides the relationship between percentage of total ground rod resistance and the radial

    distance from the ground rod (IEEE STD 142-1991, Table 9).

    .

    TABLE 4-2 TOTALGROUNDRODRESISTANCEVS. DISTANCEFROMGROUNDROD

    Distance from Electrode Surface (r)**

    Approximate Percentage of

    ft Meters Total Resistance

    0.1 0.03 25%

    0.2 0.06 38%

    0.3 0.09 46%

    0.5 0.15 52%

    1.0 0.3 68%

    5.0 1.5 86%

    10.0* 3.0* 94%

    15.0 4.6 97%

    20.0 6.1 99%

    25.0 7.6 100%

    * 94% of the resistance to remote earth occurs within a radius equal to the length of the ground rod. This

    radius is commonly used as the ground rod's sphere of influence.

    ** Ground rod resistance at a radius (r) from a 3 m 16 mm (10 ft. 0.625 in.) ground rod(From IEEE STD 142-1991, Table 9)

    The following observations can be made from the above table (IEEE STD 142-1991, chapter 4):

    Within the first 2.5 cm (1 in.) from the ground rod, 25% of the total resistance to earth is achieved.

    4-10 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    11/100

    STANDARDS ANDGUIDELINES FORCOMMUNICATIONSITES GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATION

    REQUIREMENTS

    Within the first 152 mm (6 in.) from the ground rod, 52% of the total resistance to earth is achieved

    The area immediately around a ground rod is the most important for reducing its resistance to earth.

    See Grounding (Earthing) Electrode Encasement Materials on page 4-27for information on

    reducing resistance.

    In high resistivity soil areas, decreasing the soil resistance in this area is useful in improving

    the effectiveness of the grounding electrode system.

    In porous soil areas, decreasing the contact resistance with the ground rod in this area is useful

    in improving the effectiveness of the grounding electrode system.

    Unless specified elsewhere in this chapter, ground rods should be installed apart from one another by

    the sum of their respective lengths, so their spheres of influence do not overlap (See Figure 4-6). This is

    especially important when only a small number of ground rods are installed, such as around tower

    ground rings.

    24.4 m (80 ft.)straight line will achieve a resistance to earth of 7.8 ohms (assuming 10,000 ohm-cmsoil). Nine 3 m (10 ft.)ground rods installed 3 m (10 ft.)apart in the same 24.4 m (80 ft.)straight line

    will achieve a resistance to earth of 5.7 ohms.

    N

    apart in an)ground rods installed 6.1 m (20 ft.)apart from one another). For example, five 3 m (10 ft.

    will achieve a lower resistance to earth than fewer rods installed further apart (such as twice the length

    In a given area, more ground rods installed closer together (such as one length apart from one another):OTE

    4.4.1.2 GROUNDRODS

    Typical ground rods are shown in Figure 4-7. Requirements for ground rods are listed below. See IEEE

    STD 142-1991, section 4.3.1 and UL 467-2004 for additional information.

    FIGURE 4-7 TYPICALGROUNDRODS

    4.4.1.2.1 GROUNDRODSPECIFICATIONS

    Ground rods shallbe UL listed (or equivalent).

    Ground rods shallbe constructed of copper-clad steel, solid copper, hot-dipped galvanized steel, or

    stainless steel (ANSI-J-STD-607-A-2002, section C.4.3, and ANSI T1.334-2002, section 5.3.2).

    See NFPA 70-2005, Article 250.52 and UL 467-2004, section 9.2.1 for additional information.

    68P81089E50-B 9/1/05 4-11

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    12/100

    GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATIONREQUIREMENTS CHAPTER4: EXTERNALGROUNDING(EARTHING)

    NOTE: Stainless steel ground rods shallbe formed of an austenitic stainless steel of the 18 percent chromium, 8percent nickel type (UL 467-2004, section 9.2.6).

    Ground rods shallhave a minimum length of 2.4 m (8 ft.) (ANSI T1.313-2003, section 10.3.1,

    ANSI T1.334-2002, section 5.3.2, NFPA 70-2005, Article 250.52, and UL 467-2004). For areas

    highly prone to lightning, and/or military installations, longer rods, such as 3 m (10 ft.), should be

    considered for the minimum length (MIL-HDBK-419A and MIL-STD-188-124B).

    Ground rods shall have a minimum diameter of 15.9 mm (0.625 in.) (ANSI T1.313-2003, section

    10.3.1 and ANSI T1.334-2002, section 5.3.2), unless otherwise allowed by the UL listing of the

    ground rod (UL 467). See NFPA 70-2005, Article 250.52 for additional information.

    Ground rods shall be free of paint or other nonconductive coatings (NFPA 70-2005, Article 250.53

    and NFPA 780-2004, section 4.13.2).

    4.4.1.2.2 GROUNDRODINSTALLATION

    Where practical, ground rods shallbe buried below permanent moisture level (MIL-HDBK-419A

    and NFPA 70-2005, Article 250.53).

    Where practical, ground rods shallpenetrate below the frost line (MIL-HDBK-419A).

    Ground rods longer than the minimum required 2.4 m (8 ft.) may be required to maintain contact

    with permanently moist, unfrozen soil (MIL-HDBK-419A).

    When part of a ground ring system, the upper end of the ground rods shall be buried to the depth of

    the ground ring, typically 762 mm (30 in.) minimum below finished grade. The upper end of the

    ground rods should be buried to the same depth as the ground ring to allow for easy bonding to the

    ground ring. (See External Building and Tower Ground Ring on page 4-22.)

    When not part of a ground ring system, such as in a Type A site, the entire length of the rod shallbe

    in contact with soil (NFPA 70-2005, Article 250.53). It is recommended to install the ground rods

    so the upper end of the rod is buried to a minimum depth of 610 mm (24 in.) below the surface of

    the earth (NFPA 780-2004, section 4.13.2.3). See Figure 4-8for typical single ground rod

    installations.

    4-12 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    13/100

    STANDARDS ANDGUIDELINES FORCOMMUNICATIONSITES GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATION

    REQUIREMENTS

    GROUNDING CONDUCTORGROUNDING CONDUCTOR

    TOP OF ROD JUSTBELOW SOIL

    SURFACE

    610 mm(2 ft)

    3 m(10 ft.)

    .4m

    (8 ft.)

    2.4 m(8 ft.)

    RECOMMENDED DEPTH MINIMUM DEPTH

    FIGURE 4-8 TYPICALSINGLEGROUNDRODINSTALLATION

    Ground rods shall notbe installed closer than 1.8 m (6 ft.) from other ground rods and grounding

    electrodes (NFPA 70-2005, Article 250.56). See Figure 4-31 on page 4-49for an example.

    Unless otherwise stated in this chapter, ground rods shall not be installed closer to one another than

    the sum of their respective lengths, when possible. This is especially important for the ground rodsassociated with tower ground rings. See Grounding (Earthing) Electrode Resistance

    Characteristics and Sphere of Influence on page 4-9

    See External Building and Tower Ground Ring on page 4-22for ground rod installation

    requirements on ground rings.

    The method of bonding grounding conductors to ground rods shallbe compatible with the types of

    metals being bonded (See Dissimilar Metals and Corrosion Control on page 4-34).

    Ground rods that cannot be driven straight down, due to contact with rock formations, may be

    driven at an oblique angle of not greater than 45 degrees from the vertical, or may be buried

    horizontally and perpendicular to the building, in a trench at least 762 mm (30 in.) deep, as shown

    in Figure 4-9(NFPA 70-2005, Article 250.53).

    IMPORTANT:The top of a ground rod shall notbe cut off if contact with rocks prevents driving of the

    rod. Alternate driving techniques, as describe above, shallbe used in these cases.

    68P81089E50-B 9/1/05 4-13

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    14/100

    GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATIONREQUIREMENTS CHAPTER4: EXTERNALGROUNDING(EARTHING)

    BURIED GROUNDING ELECTRODECONDUCTORS

    2.4 m(8 ft)

    45

    maximum

    76 cm

    (2.5 ft)

    FIGURE 4-9 ANGLEDGROUNDRODINSTALLATION

    WARNING

    When operating any kind of power tool, always wear appropriate safety glasses and

    other protective gear to prevent injury.

    Hammer drills or electric jackhammers may be used to drive in the ground rods. Do not deform the

    head of the ground rod. See IEEE STD 142-1991, section 4.3.2. for additional information.

    If rock formations prevent ground rods from being driven to the specified depth, an alternate

    method of achieving an acceptable grounding electrode system shallbe engineered and

    implemented. See Special Grounding (Earthing) Situations on page 4-88for additional

    information.

    When the grounding electrode system design requires deeper ground rods (in order to lower the

    grounding electrode system resistance, penetrate down to permanent moisture level, or to penetrate

    below the frost line) two or more ground rods may be joined together by use of a coupling

    (threaded, compression sleeve, or exothermic weld). Threaded rods or compression sleeves shallbe

    UL listed. (IEEE STD 142-1991, section 4.3.1). See Figure 4-10for an example of splicingground rods together.

    FIGURE 4-10 SPLICINGTWOGROUNDRODS

    4-14 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    15/100

    STANDARDS ANDGUIDELINES FORCOMMUNICATIONSITES GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATION

    REQUIREMENTS

    4.4.1.2.3 EFFECT OFGROUNDRODSIZE ONRESISTANCE TOEARTH

    Increasing the diameter of a ground rod does not significantly reduce its resistance to earth. Doubling

    the diameter of a rod reduces its resistance to earth by approximately 10%. See Figure 4-11.

    0

    5

    10

    15

    20

    25

    30

    35

    40

    45

    50

    A

    pproximateResistancetoEarthinOhms

    0.50 0.75 1.00 1.25 1.50 1.75

    Ground Rod Diameter (Inches)

    3 m (10 ft) Ground Rod in 10,000 ohm-cm soil

    FIGURE 4-11 RESISTANCE TOEARTHDUE TOGROUNDRODDIAMETER

    As the length of a ground rod is increased, its resistance to earth is substantially reduced. In general,

    doubling the length of a ground rod reduces the resistance to earth by 40%. See Figure 4-12.

    140

    120

    ApproximateResistancetoEarthinOhms

    100

    80

    60

    40

    20

    0

    2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

    Ground Rod Length (Feet)

    15.9 mm (0.625 in.) Diameter Ground Rod in 10,000 ohm-cm soil

    FIGURE 4-12 RESISTANCE TOEARTHDUE TOGROUNDRODLENGTH

    68P81089E50-B 9/1/05 4-15

    2.0

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    16/100

    GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATIONREQUIREMENTS CHAPTER4: EXTERNALGROUNDING(EARTHING)

    4.4.1.2.4 EFFECT OFPARALLELGROUNDRODS

    Figure 4-13below shows the effects of adding additional ground rods (15.9 mm (0.625 in.) diameter by

    3 m (10 ft.)long) together in parallel. As seen in the figure, the addition of one ground rod to the first

    ground rod (for a total of two rods) significantly reduces the resistance to earth of the ground rod

    system. Each subsequent ground rod added in parallel has less of an effect on the resistance to earth of

    the ground rod system.

    ApproximateResistancetoEarthinOhms

    35

    30

    25

    20

    15

    10

    5

    0

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

    Number of 3 m (10 ft) Ground Rods

    Installed 6.1 m (20 ft) apart in 10,000 ohm-cm soil

    FIGURE 4-13 RESISTANCE TOEARTHDUE TOPARALLELGROUNDRODS

    4.4.1.3 ELECTROLYTICGROUNDRODS

    At sites where, due to poor soil conductivity (high resistivity) and/or limited space, an acceptable

    grounding (earthing) electrode system resistance cannot be achieved using standard ground rods,

    commercially available electrolytic ground rods should be considered. See MIL-HDBK-419A Volume

    I, section 2.9.5, and UL 467-2004, section 9.2.7 for additional information. Electrolytic ground rods

    (Figure 4-14) are available in straight or L-shaped versions and in various lengths from 3 m (10 ft.) to

    6.1 m (20 ft.), or longer as a special order. Electrolytic ground rods are generally constructed of 54 mm

    (2.125 in.) diameter hollow copper pipe. This copper pipe is filled with a mixture of non-hazardous

    natural earth salts. Holes at various locations on the pipe allow moisture to be hygroscopically extracted

    from the air into the salt within the pipe, therefore forming conductive electrolytes. These electrolytes

    then leach out of the pipe into the soil, improving soil conductivity. Electrolytic ground rods are insertedinto a pre-drilled hole, or in the case of L-shaped rods, placed into a trench at least 762 mm (30 in.)

    deep, and encased in a grounding electrode encasement material. See Grounding (Earthing) Electrode

    Encasement Materials on page 4-27.

    Electrolytic ground rods should be considered for use in grounding electrode systems covered by

    concrete or pavement, such as parking lots. By allowing moisture to enter, the design of the electrolytic

    ground rod improves the resistance of the grounding electrode system.

    4-16 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    17/100

    STANDARDS ANDGUIDELINES FORCOMMUNICATIONSITES GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATION

    REQUIREMENTS

    NOTE: Unless prohibited by local environmental authorities, condensation from the site's HVAC system maybe routed to the ground rod area to keep the soil moist, improving conductivity.

    Electrolytic ground rods may provide significant improvement over standard ground rods of the same

    length and may last several years longer than standard ground rods. The resistance to earth of

    electrolytic ground rods is generally more stable in environments with variations in temperature and

    moisture.

    Requirements for the use of electrolytic ground rods are listed below:

    Electrolytic rods shallbe UL listed (or equivalent).

    Electrolytic rods shallbe installed per the manufacturers' recommendation.

    Electrolytic rods shall be free of paint or other nonconductive coatings (NFPA 70-2005, Article

    250.53 and NFPA 780-2004, section 4.13.2.2).

    Electrolytes within the rod shallbe environmentally safe and approved by the environmental

    authority having jurisdiction.

    L-shaped electrolytic rods shallbe installed perpendicular to the building or shelter.

    L-shaped electrolytic rods (horizontal portion) shallbe installed at least 762 mm (30 in.) below theearth's surface.

    Grounding electrode encasement materials (also known as backfill) shallbe environmentally safe

    and approved by the environmental authority having jurisdiction. See Grounding (Earthing)

    Electrode Encasement Materials on page 4-27.

    Electrolytic rods should be maintenance free.

    68P81089E50-B 9/1/05 4-17

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    18/100

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    19/100

    STANDARDS ANDGUIDELINES FORCOMMUNICATIONSITES GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATION

    REQUIREMENTS

    4.4.1.4 GROUNDPLATEELECTRODES

    Ground plates (Figure 4-15) may be used in special cases, or if specifically engineered into the design

    of the grounding (earthing) electrode system. Requirements for the use of ground plate electrodes are

    listed below:

    Ground plates should only be used if soil conditions prohibit the use of standard ground rods, or if

    specifically engineered into the grounding electrode system.

    Ground plates should be UL listed (or equivalent).

    Ground plates shallbe constructed of copper or copper-clad steel.

    Ground plates shallexpose not less than 0.37 m2(2 ft.2) of surface to exterior soil (MIL-HDBK

    419A, section 2.5.5; NFPA 70-2005, Article 250.52; and NFPA 780-2004, section 4.13.6.1).

    Ground plates shallhave a minimum thickness of 1.5 mm (0.06 in.) (MIL-HDBK-419A, section

    2.5.5 and NFPA 70-2005, Article 250.52).

    Ground plates shallbe free of paint or other nonconductive coatings (NFPA 70-2005, Article

    250.53 and NFPA 780-2004, section 4.13.2.2).

    Ground plates shallbe buried not less than 762 mm (30 in.) below the surface of the earth (NFPA

    70-2005, Article 250.53). If soil conditions do not allow the ground plate to be buried at this depth,

    see Shallow Topsoil Environments on page 4-97for additional information.

    Where practical, a ground plate shallbe embedded below permanent moisture level

    (BS 7430:1998, clause 10 and NFPA 70-2005, Article 250.53).

    Ground plates should be installed vertically to allow for minimum excavation and better contact

    with the soil when backfilling (BS 7430:1998, clause 10 and IEEE STD 142-1991, section 4.2.4).

    See Figure 4-16.

    STRAIGHT EDGESSERRATED EDGES PROVIDE MORE

    EDGE SURFACE

    FIGURE 4-15 TYPICALGROUNDPLATES

    68P81089E50-B 9/1/05 4-19

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    20/100

    GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATIONREQUIREMENTS CHAPTER4: EXTERNALGROUNDING(EARTHING)

    GROUND PLATE

    1.5 mm0.06 in.

    #2 AWG BARECOPPER WIRE T

    R ND RINMINIMUM)

    BACKFILL MA ERIAL152 mm MINIMUM 6 IN.

    ON ALL SIDES

    EXOTHERMIC

    CONNECTION

    T P ED E F PLATE

    762 mm (30 IN.) BELOW GRADE

    SITE SOIL

    FIGURE 4-16 TYPICALGROUNDPLATEINSTALLATION

    A grounding electrode encasement material should be used to backfill around the ground plate to

    help insure effective contact with the earth (BS 7430:1998, clause 10). See Grounding (Earthing)

    Electrode Encasement Materials on page 4-27.

    4.4.1.5 CONCRETE-ENCASEDELECTRODES

    Though concrete-encased electrodes (also known as Ufer electrodes, named after Herbert G. Ufer, or

    foundation earth electrodes) are not required by this standard, they should be used in new construction

    as a method of supplementing the grounding (earthing) electrode system (IEC 61024-1-2, section 3.3.5).

    Concrete-encased electrodes (Figure 4-17) enhance the effectiveness of the grounding electrode system

    in two ways: the concrete absorbs and retains moisture from the surrounding soil, and the concrete

    provides a much larger surface area in direct contact with the surrounding soil. This is especially helpful

    at sites with high soil resistivity and/or limited area for installing a grounding electrode system. See

    IEEE STD 142-1991 section 4.2.3, and the International Association of Electrical Inspectors

    publication, Soares Book on Grounding and Bonding, 9th Edition, Appendix A for additional

    information. Requirements for a concrete-encased electrode, if used, are listed below (IEC 61024-1-2;

    NFPA 70-2005, Article 250.52; and NFPA 780-2004, section 4.13.3).

    Concrete-encased electrodes shall be encased by at least 51 mm (2 in.) of concrete, located within

    and near the bottom of a concrete foundation or footing that is in direct contact with the earth.

    Concrete-encased electrodes shall be at least 6.1 m (20 ft.) of bare copper conductor not smaller

    than 25 mm2csa (#4 AWG) or at least 6.1 m (20 ft.) of one or more bare or zinc galvanized or other

    conductive coated steel reinforcing bars or rods at least 12.7 mm (0.5 in.) in diameter.

    Concrete-encased electrodes shallbe bonded to any other grounding electrode system at the site.

    See Common Grounding (Earthing) on page 4-5.

    4-20 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    21/100

    STANDARDS ANDGUIDELINES FORCOMMUNICATIONSITES GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATION

    REQUIREMENTS

    25 mm2CSA (#4 AWG) OR

    COARSER BARE COPPER GROUNDING ELECTRODECONDUCTOR OR STEEL CONDUCTORREINFORCING BAR OR ROD, NOTLESS THAN 12.7 mm (0.5 in.) NONMETALLIC

    DIAMETER AND AT LEAST 6.1 m PROTECTIVE SLEEVE(20 ft) LONG

    CONNECTION LISTEDFOR THE PURPOSE

    51 mm(2 in.)

    MINIMUM

    FOUNDATION IN DIRECT CONTACT WITH EARTH

    CLAMP SUITABLE FOR ENCASEMENT

    OR EXOTHERMIC WELD

    MINIMUM 6.1 m (20 ft)

    END VIEWSIDE VIEW

    225 mm csa (#4 AWG)

    COPPER CONDUCTOR

    MINIMUM 6.1 m (20 ft)

    SIDE VIEW END VIEW

    12.7 mm (0.5 in.) REBAR

    (TYPICAL)

    FIGURE 4-17 TYPICALCONCRETE-ENCASEDELECTRODES

    68P81089E50-B 9/1/05 4-21

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    22/100

    GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATIONREQUIREMENTS CHAPTER4: EXTERNALGROUNDING(EARTHING)

    4.4.1.6 EXTERNALBUILDING ANDTOWERGROUNDRING

    The buried external ground rings (building and tower) provide a means of bonding ground rods together

    and bonding other grounding (earthing) electrode system components together, improving the overall

    grounding electrode system. The ground rings also help to equalize potential in the earth surrounding

    the tower and building structures, regardless of earth resistivity, by insuring that a low impedance

    current path exists throughout the area (ANSI T1.334-2002, section 5.3).

    Requirement for external ground rings are listed below (see Figure 4-18):

    Unless otherwise stated, ground ring conductors shallbe 35 mm2csa (#2 AWG) or coarser, bare,

    solid, tinned or un-tinned, copper (ANSI T1.313-2003 and ANSI T1.334-2002, section 5.3.1). See

    Grounding (Earthing) Conductors on page 4-28for grounding conductor specifications.

    Solid, bare, tinned, copper conductor should be used to minimize galvanic corrosion between tower

    legs and other parts of the grounding electrode system (ANSI T1.313-2003, section 10.7).

    For areas highly prone to lightning, and/or military installations, larger conductors, such as

    50 mm2 csa (#1/0 AWG) or coarser, should be considered (MIL-HDBK-419A and MIL-STD-188

    124B); stranded conductors may be used in this application.

    Building ground rings shallencircle the building or shelter whenever possible (ANSI T1.313-2003,ANSI T1.334-2002, MIL-HDBK-419A, and MIL-STD-188-124B).

    Tower ground rings shallencircle the tower structure whenever possible (ANSI T1.334-2002,

    section 5.3 and MIL-HDBK-419A).

    The ends of the conductor shallbe joined together to form a ring using an exothermic weld or listed

    irreversible high-compression connector (ANSI T1.334-2002, section 5.3.1 and MIL-STD-188

    124B). This may be easily completed at a ground rod.

    Building ground rings and tower ground rings shall be bonded together in at least two points using

    a 35 mm2 csa (#2 AWG) or coarser, bare, solid, tinned or un-tinned, copper conductor (ANSI-J

    STD-607-A-2002, section C.4.7, ANSI T1.334-2002, figure 1, and MIL-STD-188-124B). The

    conductors should be physically separated as much as practical. See Common Grounding

    (Earthing) on page 4-5.

    4-22 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    23/100

    STANDARDS ANDGUIDELINES FORCOMMUNICATIONSITES GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATION

    REQUIREMENTS

    FIGURE 4-18 BONDINGBUILDING ANDTOWERGROUNDRINGSYSTEMS

    Ground rings shallbe installed in direct contact with the earth at a depth of 762 mm (30 in.) below

    the earth's surface whenever possible, or below the frost line, whichever is deeper (ANSI T1.334

    2002, section 5.3.1 and NFPA 70-2005, Article 250.53).

    Building ground rings shallbe installed at least 914 mm (3 ft.) from the building foundation and

    should be installed beyond the drip line of the roof. It is recommended that the building ground ring

    and ground rods be positioned 610 mm to 1.8 m (2 ft. to 6 ft.) outside the drip line of the building or

    structure to ensure that precipitation wets the earth around the ground ring and rods (MIL-HDBK

    419A and MIL-STD-188-124B).

    Tower ground rings shallbe installed at least 610 mm (2 ft.) from the tower foundation (ANSI

    T1.334-2002, section 5.3.1).

    If 2.4 m (8 ft.)ground rods are installed along the ground rings, they shallbe connected to the

    ground ring conductor at 3 m to 4.6 m (10 ft. to 15 ft.)intervals (ANSI T1.334-2002), unless

    otherwise specified.

    If longer ground rods are used, a larger separation proportional to the increase in rod length

    may be used.

    Ground rods shallbe placed a minimum of one rod length apart from one another along the

    ground rings (ANSI T1.313-2003, figure 3(a)).

    Ground rods shall notbe separated from an adjacent ground rod along the ground ring by more

    than the sum of their respective lengths. (MIL-HDBK-419A).

    TOWER RING BONDED TO

    BUILDING RING IN AT

    LEAST 2 PLACES

    68P81089E50-B 9/1/05 4-23

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    24/100

    GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATIONREQUIREMENTS CHAPTER4: EXTERNALGROUNDING(EARTHING)

    4.4.1.7 RADIAL(COUNTERPOISE) GROUNDINGCONDUCTORS

    For high lightning prone geographical areas, sites normally occupied (such as 911 dispatch centers),

    sites with high soil resistivity, or when bedrock prohibits the driving of ground rods, radial

    (counterpoise) grounding (earthing) conductors should be employed to improve equalization of the

    grounding electrode system (ANSI T1.334-2002, section 5.4), and to help meet the site's grounding

    electrode system resistance requirements (see Grounding (Earthing) Electrode System Resistance

    Requirements on page 4-46). Radial grounding conductors are conductors installed horizontally in the

    ground and radiating away from the tower and building.

    In typical soil resistivity conditions of 10, 000 ohm-cm, the addition of five radial conductors 7.6 m

    (25 ft)in length may reduce the tower grounding electrode system resistance by a factor of two or three.

    More importantly, adding radial conductors divides lightning strike current into segments that allow for

    more effective dissipation of energy into the earth, and away from the equipment building.

    When used, radial conductors shall meet the following specifications:

    The conductors shallradiate away from the building and tower (ANSI T1.334-2002, section 5.4).

    The conductors shallbe installed at the tower or tower ground ring whenever possible. If the

    conductors cannot be installed at the tower, installation at the building is acceptable, but should be

    installed near the RF transmission line entry point.

    FIGURE 4-19 INSTALLATION OFRADIALCONDUCTORS

    When radial conductors are used, a minimum of three to five conductors should be used.

    The conductors shall be installed equally spaced from one another, as much as practical.

    4-24 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    25/100

    ----------------------

    STANDARDS ANDGUIDELINES FORCOMMUNICATIONSITES GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATION

    REQUIREMENTS

    The conductors shallbe bonded directly to the tower and tower ground ring (ANSI T1.334-2002,

    section 5.4). If it is not practical to bond all conductors to the tower, the tower shallhave additional

    grounding conductors bonding it to the tower ground ring; 70 mm2(#2/0 AWG) or coarser

    conductor is recommended in this case.

    Conductor bonding shallcomply with Bonding to the External Grounding (Earthing) Electrode

    System on page 4-40

    The conductors shallbe constructed of 35 mm2csa (#2 AWG) or coarser, bare, solid, tinned or un

    tinned, copper. See Grounding (Earthing) Conductors on page 4-28for conductor specifications

    and installation requirements. (ANSI T1.334-2002, section 5.4)

    The conductors shallbe buried at least 457 mm (18 in.) below ground (ANSI T1.334-2002,

    section 5.4). When topsoil conditions allow, it is recommended to bury the conductors to a depth of

    at least 762 mm (30 in.) (ANSI-J-STD-607-A-2002, section C.9.2); this is especially important in

    areas where the frost line may reach 457 mm (18 in.).

    The minimum length of each conductor shallbe 7.6 m (25 ft.). If the desired resistance to earth is

    not achieved at 7.6 m (25 ft.), the radial conductor may be extended to help obtain the desired

    resistance (ANSI T1.334-2002, section 5.4). The maximum effective length for a single radial

    conductor is generally considered to be approximately 24.4 m (80 ft.). Adding additional

    conductors is generally more effective than extending the length of a single conductor.

    NOTE: When multiple radial conductors are used, the conductors should be of different lengths to help preventresonant ringing of the tower from a lightning strike.

    NOTE: Low resistance in radial (counterpoise) grounding configurations is desirable, but not critical. Lowresistance in the dissipating path of strike currents into the earth is of secondary importance when

    compared to the primary objective of controlling voltage gradients and voltage differences between

    structures and equipment close to the tower (ANSI T1.334-2002, section 5.4).

    When soil conditions allow, the effectiveness of the radial grounding conductor may be increasedby including a ground rod every 4.9 m (16 ft.) (or twice the length of the ground rods) installed as

    described in Ground Rods on page 4-11. See Figure 4-19 on page 4-24for an example of ground

    radials.

    Figure 4-20 on page 4-26shows the resistance characteristics of a radial grounding conductor. The

    resistance to earth of a straight horizontal electrode (radial grounding conductor) may be calculated as

    follows:

    1 2LR = ------ ln

    )1 2L (2aD /

    Where:

    D

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    26/100

    GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATIONREQUIREMENTS CHAPTER4: EXTERNALGROUNDING(EARTHING)

    ApproximateResistancetoEarthinOhms

    Ap

    proximateResistancetoEarthinOhms

    40

    35

    30

    25

    20

    15

    10

    5

    0

    10 20

    40

    35

    30

    25

    20

    15

    10

    5

    0

    Radial Grounding Conductor Resistance

    AWG # 2

    Buried 457 mm (18 in.) in 10,000 ohm-cm soil

    Buried 762 mm (30 in.) in 10,000 ohm-cm soil

    30 40 50 60 70 80

    Radial Grounding Conductor Length (feet)

    Radial Grounding Conductor Resistance

    AWG # 2/0

    Buried 457 mm (18 in.) in 10,000 ohm-cm soil

    Buried 762 mm (30 in.) in 10,000 ohm-cm soil

    10 20 30 40 50 60 70 80

    Radial Grounding Conductor Length (feet)

    FIGURE 4-20 RESISTANCECHARACTERISTICS OF ARADIALGROUNDINGCONDUCTOR

    4-26 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    27/100

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    28/100

    GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATIONREQUIREMENTS CHAPTER4: EXTERNALGROUNDING(EARTHING)

    Grounding electrode encasement material shallbe packaged for the purpose of grounding electrode

    encasement.

    Grounding electrode encasement material shallbe environmentally safe and approved by the

    environmental authority having jurisdiction.

    Grounding electrode encasement material shallbe used in accordance with the manufacturers'

    instructions.

    Grounding electrode encasement material shall nothave a corrosive effect on the grounding

    electrode system components.

    The use of charcoal or petroleum based coke breeze is not recommended as it may result in rapid

    corrosion of copper electrodes and copper conductors (BS 7430:1998, clause 8.5; BS 6651:1999,

    clause 18.4.2; and FAA STD 019d-2002, section 3.8.3.5). Charcoal and petroleum based coke

    typically contains high levels of sulfur, which in the presence of moisture will accelerate corrosion.

    Coke breeze derived from coal in coke ovens is generally considered acceptable; all the corrosives

    and volatiles have been cooked off at extremely high temperatures (FAA STD 019d-2002, section

    3.8.3.5).

    Per MIL-HDBK-419A, the suggested grounding electrode encasement (backfill) material is a mixture

    of 75 percent gypsum, 20 percent bentonite clay, and 5 percent sodium sulfate. The gypsum, which is

    calcium sulfate, absorbs and retains moisture and adds reactivity and conductivity to the mixture. Since

    it contracts very little when moisture is lost, it will not pull away from the ground rod or surrounding

    earth. The bentonite ensures good contact between the ground rod and earth by its expansion, while the

    sodium sulfate prevents polarization of the ground rod by removing the gases formed by current

    entering the earth through the ground rod. This mixture is readily available from cathodic protection

    distributors as standard galvanic anode backfill. The backfill mixture should be covered with 305 mm

    (12 in.) of excavated soil. See MIL-HDBK-419A Volume I, section 2.9 for additional information.

    4.4.2 GROUNDING(EARTHING) CONDUCTORS

    Grounding (earthing) conductors are the conductors used to connect equipment or the grounded circuitof a wiring system to a grounding electrode or grounding electrode system. These conductors may

    connect grounding electrodes together, form buried ground rings, and connect objects to the grounding

    electrode system. See BS 7430:1998, clause 3.17 and NFPA 70-2005, Article 100 for additional

    information.

    4.4.2.1 GENERALSPECIFICATIONS

    General specifications for grounding (earthing) conductors are listed below.

    Unless otherwise stated, all below-ground, or partially below-ground, external grounding electrode

    system conductors shallbe 35 mm2 csa (#2 AWG) or coarser, bare, solid, tinned or un-tinned,

    copper conductors (ANSI T1.313-2003 and ANSI T1.334-2002, section 5.3). For areas highlyprone to lightning, and/or military installations, larger conductors, such as 50 mm2csa (#1/0 AWG)

    or coarser, should be considered (MIL-HDBK-419A); stranded conductors may be used in this

    application. Tinned conductors are recommended for stranded conductors.

    Solid, bare, tinned, copper conductors should be used to help minimize galvanic corrosion between

    tower legs and other parts of the grounding electrode system (ANSI T1.313-2003, section 10.7).

    See Dissimilar Metals and Corrosion Control on page 4-34.

    4-28 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    29/100

    STANDARDS ANDGUIDELINES FORCOMMUNICATIONSITES GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATION

    REQUIREMENTS

    Grounding electrode conductors shall be installed in one continuous length without a splice or

    joint, unless spliced using irreversible compression-type connectors listed for the purpose or by

    exothermic welding (NFPA 70-2005, Article 250.64). See Bonding Methods on page 4-41for

    additional information.

    Above-ground conductors used for bonding individual metallic objects shallbe 16 mm2csa (#6

    AWG) or coarser, tinned or un-tinned, copper conductors (ANSI T1.334, section 5.3.3). See

    Metallic Objects Requiring Bonding on page 4-67for additional information.

    Above-ground conductors used for bonding multiple metallic objects (used as a ground bus

    conductor) shallbe 35 mm2csa (#2 AWG) or coarser, tinned or un-tinned, copper conductors. See

    Metallic Objects Requiring Bonding on page 4-67.

    Above-ground bonding conductors should be jacketed, whenever practical (ANSI T1.334-2002,

    section 5.1).

    Solid straps or bars may be used as long as the cross-sectional area equals or exceeds that of the

    specified grounding conductor.

    WARNING

    The AC power system grounding conductors shall be sized appropriately for the

    electrical service and shall be approved by the authority having jurisdiction.

    4.4.2.2 BENDINGANDROUTINGGROUNDING(EARTHING) CONDUCTORS

    Grounding (earthing) conductors shall be run in a direct manner with no sharp bends or narrow loops

    (ANSI T1.313-2003, section 11.3, and ANSI T1.334-2002, section 13.4). Sharp bends and/or narrow

    loops increase the impedance and may produce flash points (also see NFPA 780-2004, section 4.9.5).

    The following requirements apply when installing grounding system conductors:

    Sharp bends shallbe avoided (ANSI T1.334-2002, section 13.4).

    Grounding conductors shallbe run as short, straight, and smoothly as possible, with the fewest

    possible number of bends and curves (ANSI T1.313-2003, section 11.3; ANSI T1.334-2002,section 13.4; and NFPA 70-2005, Articles 800.100, 810.21, and 820.100).

    A minimum bending radius of 203 mm (8 in.) shallbe maintained, applicable to grounding

    conductors of all sizes (ANSI T1.313-2003, section 11.3; MIL-STD-188-124B; and NFPA 780

    2004, section 4.9.5). A diagonal run is preferable to a bend even though it does not follow the

    contour or run parallel to the supporting structure. See Figure 4-22.

    All bends and curves shall be made toward the ground location (grounding electrode system or

    ground bar).

    The radius of any bend shall notbe less than 203 mm (8 in.)

    Radius

    90 degrees

    minimum

    The angle of any bend shall notbe less than 90 degrees.

    FIGURE 4-22 MINIMUMBENDINGRADIUSFORGROUNDINGCONDUCTORS

    68P81089E50-B 9/1/05 4-29

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    30/100

    GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATIONREQUIREMENTS CHAPTER4: EXTERNALGROUNDING(EARTHING)

    4.4.2.3 PROTECTING ANDSECURINGGROUNDING(EARTHING) CONDUCTORS

    Above ground external grounding (earthing) conductors, including straps, are exposed to movement by

    wind and other physical forces that can lead to damage or breakage over time. The following

    requirements shallapply when installing grounding conductors:

    Grounding conductors shallbe protected where exposed to physical damage (NFPA 70-2005,

    Articles 250.64, 800.100, 810.20, 820.100; and NFPA 780-2004, section 4.9.11).

    Grounding conductors exposed to physical damage shall be protected for a minimum distance of

    1.8 m (6 ft.) above grade level (NFPA 780-2004, section 4.9.11.2). Such areas may include, but are

    not limited to, runways, driveways, school playgrounds, cattle yards, public walks (NFPA 780

    2004, section 4.9.11).

    Metallic guards and/or conduits used to protect grounding conductors shallbe bonded to the

    grounding conductor at both ends (NFPA 70-2005, Article 250.64 and NFPA 780-2004, section

    4.9.11.1).

    The grounding conductor or its enclosure shall be securely fastened to the surface on which it is

    carried (NFPA 70-2005, Articles 250.64 and 810.21; and NFPA 780-2004, section 4.10).

    Grounding conductors shallbe secured using appropriate hardware intended for the purpose.

    When metallic fasteners are used on bare grounding conductors, fasteners of the same material

    shallbe used, or approved bonding techniques shallbe observed for the connection of dissimilar

    metals. See Dissimilar Metals and Corrosion Control on page 4-34. See NFPA 780-2004, section

    4.10.2 for additional information.

    Above ground grounding conductors shall be securely fastened at intervals not exceeding 91 cm

    (3 ft.) where practical. (ANSI T1.334-2002, section 8.3 and NFPA 780-2004, Section 4.10)

    4.4.3 EXTERNALGROUNDBUSBAR

    The purpose of the external ground bus bar (EGB) is to provide a convenient grounding (earthing)

    termination point for antenna transmission lines (coaxial cables) and other cables prior to their entry

    into a building or shelter (ANSI T1.313-2003). Antenna transmission lines and other communications

    cables with metallic sheaths shallbe grounded as close as practical to their point of entry into the

    building or shelter (NFPA 70-2005, articles 770.93, 800.100, 810.20, 820.93, and 820.100).

    Requirements for external ground bus bars, when used, are listed below:

    The EGB shall be constructed and minimally sized in accordance with Table 4-3 on page 4-32,

    ensuring the ground bus bar is large enough to accommodate all transmission lines and other

    grounding connections.

    The EGB shall be designed for the purpose of grounding and should be UL listed,

    The EGB shallbe installed at the point where the antenna transmission lines and other

    communications cables enter the building or shelter.

    The EGB shallbe connected directly to the grounding electrode system using a downward run of

    35 mm2csa (#2 AWG) or coarser, bare, solid or stranded, tinned or un-tinned, copper conductor; it

    is recommended to use a larger conductor, such as 120 mm2(#4/0 AWG) (United States National

    Weather Service Manual 30-4106-2004, Lightning Protection, Grounding, Bonding, Shielding,

    and Surge Protection Requirements). See Figure 4-23. The grounding conductor shallbe installed

    in a direct manner with no sharp bends or narrow loops. (See Bending And Routing Grounding

    (Earthing) Conductors on page 4-29.)

    4-30 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    31/100

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    32/100

    GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATIONREQUIREMENTS CHAPTER4: EXTERNALGROUNDING(EARTHING)

    TABLE 4-3 EXTERNALGROUNDBUSBARSPECIFICATIONS(WHENREQUIRED)

    Item Specification

    Material Bare, solid Alloy 110 (99.9%) copper bus bar or plate of one piece

    construction. May be tin-plated.

    Minimum Dimensions

    (ANSI-J-STD-607-A-2002 and NFPA 70-2005, Article 250.64)

    Height: 51 mm (2 in.)

    Thickness: 6.35 mm(0.25 in.)

    Length: Variable to meet the application requirements and allow

    for future growth. 305 mm (12 in.) is recommended as the

    minimum length.

    Mounting brackets Stainless steel

    Insulators Polyester fiberglass 15 kV minimum dielectric strength flame

    resistant per UL 94 VO classification

    Conductor mounting holes Number dependent on number of conductors to be attached

    Holes to be 11 mm (0.4375 in.) minimum on 19 mm (0.75 in.)

    centers to permit the convenient use of two-hole lugs.

    Method of attachment of grounding electrode conductor Exothermic welding

    Irreversible crimp connection

    IMPORTANT: For improved lightning protection at the site, the RF transmission line entry point andEGB should be installed as low to the ground as practical; 610 mm (2 ft.) is therecommended maximum height for the RF transmission line entry point. (United States

    National Weather Service Manual 30-4106-2004, Lighting Protection, Grounding,Bonding, Shielding, and Surge Protection Requirements.) See Design Considerations

    to Help Reduce Effects of Lightning on page 2-19.

    4.4.3.1 TOWERGROUNDBUSBAR

    The purpose of the tower ground bus bar (TGB) is to provide a convenient termination point on the

    tower for multiple transmission line (coaxial) grounding (earthing) conductors. The tower ground bus

    bar should be an integral part of the tower construction. If the tower ground bus bar is not part of the

    tower construction, it shallbe constructed and minimally sized in accordance with

    Table 4-4 on page 4-34, ensuring the ground bus bar is large enough to accommodate all coaxial cable

    connections and connection to the grounding electrode system.

    The requirements for installing tower ground bus bars are as follows:

    Where a galvanized tower is not protected against precipitation run-off from copper and copperalloys, the tower ground bus bar (TGB) shallbe constructed of tinned copper. See Methods To

    Help Reduce Corrosion on page 4-38.

    The tower ground bus bar shallbe installed below the transmission line ground kits, near the area

    of the tower at the point where the antenna transmission lines transition from the tower to the

    shelter.

    The tower ground bus bar shallbe connected to the tower grounding electrode system with a

    35 mm2csa (#2 AWG) or coarser, bare, solid, tinned, copper conductor.

    4-32 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    33/100

    STANDARDS ANDGUIDELINES FORCOMMUNICATIONSITES GROUNDING(EARTHING) ELECTRODESYSTEMCOMPONENT ANDINSTALLATION

    REQUIREMENTS

    For reduced impedance to earth, the tower ground bus bar may be directly bonded to the tower,

    using hardware of materials suitable for preventing dissimilar metal reactions, if possible and

    allowed by the tower manufacturer. This is in addition to the required grounding conductor as

    described above.

    The grounding conductors shallbe run as short, straight, and smoothly as possible. See Bending

    And Routing Grounding (Earthing) Conductors on page 4-29.

    The grounding conductor may be sleeved in PVC for protection if desired (ANSI T1.313-2003,

    section 11.4). This may be required in order to keep the grounding conductor from making

    incidental contact with the tower.

    For reduced impedance to the grounding electrode system, the TGB can be connected to the external

    grounding electrode system using solid copper strap. Relatively small copper strap has significantly less

    inductance (impedance to lightning) than large wire conductors. For example, 38.1 mm (1.5 in.) copper

    strap has less inductance than 70 mm2csa (#2/0 AWG) wire. To further reduce the inductance to

    ground, several copper straps can be installed across the entire length of the tower ground bus bar and

    routed down to the external grounding ring.

    Additional ground bus bars may be installed at different heights along the vertical length of the tower

    for bonding multiple transmission line ground kits to the tower, if not already included as part of the

    tower structure. The additional ground bus bars shallbe bonded directly to the tower using tower

    manufacturer approved methods. Bonding to the tower may include the following options:

    Bolting a tin-plated bus bar directly to the tower structure using stainless steel hardware. In this

    case, a grounding conductor is not required.

    Securing a bus bar to the tower using appropriate mechanical hardware. Electrically bonding the

    bus bar to the tower using a grounding conductor. The grounding conductor should bond to the

    tower using appropriate hardware, such as stainless steel beam clamps, or stainless steel band/strap

    type clamp. The grounding conductor shallbond to the bus bar using exothermic weld, irreversible

    compression connectors, or listed compression two-hole lugs.

    TOWER GROUND BUS BAR

    TRANSMISSION LINESTO BUILDING

    TOWER GROUND RING (UNDERGROUND)

    FIGURE 4-25 TYPICALTOWERGROUNDBUSBARS

    68P81089E50-B 9/1/05 4-33

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    34/100

    DISSIMILARMETALS ANDCORROSIONCONTROL CHAPTER4: EXTERNALGROUNDING(EARTHING)

    TABLE 4-4 TOWERGROUNDBUSBARSPECIFICATIONS

    Item Specification

    Material Bare, solid Alloy 110 (99.9%) copper bus bar or plate of one piece construction. Should be

    tin-plated if installing on a galvanized tower. (See Dissimilar Metals and Corrosion

    Control on page 4-34for information regarding tower corrosion related to copper bus bars.)

    Minimum Dimensions

    (ANSI-J-STD-607-A-2002 and NFPA

    70-2005, Article 250.64)

    Height: 51 mm (2 in.)

    Thickness:6.35 mm(0.25 in.)

    Length: Variable to meet the application requirements and allow for future growth.

    305 mm (12 in.) is recommended as the minimum length.

    Mounting brackets Stainless steel

    Conductor mounting holes Number dependent on number of conductors to be attached

    Holes to be 11 mm (0.4375 in.) minimum on 19 mm (0.75 in.) centers to permit the

    convenient use of two-hole lugs.

    Method of attachment of grounding

    electrode conductor

    Exothermic welding

    Irreversible crimp connection

    4.5 DISSIMILARMETALS ANDCORROSIONCONTROL

    Although the type of metals used in a grounding (earthing) electrode system do not affect the resistance

    to earth of the grounding electrode system, consideration should be given to select a metal that is

    resistance to corrosion in the type of soil in which it will be installed. The two areas that should be

    considered regarding the corrosion resistance of a metal are the compatibility with the soil itself and

    possible galvanic corrosion effects when it is electrically connected to neighboring metals at the site.

    (BS 7430:1998)

    4.5.1 CORROSIONRELATED TOSOILTYPE

    The compatibility of a metal with soil is determined by the chemical composition of the soil. The

    chemical composition factors associated with the corrosion of metals in contact with the soil are as

    follows: acidity or alkalinity (pH), salt content, soil porosity (aeration), and the presence of anaerobic

    bacteria. (BS 7430:1998 and TIA/EIA-222-F-R2003)

    The following list gives a general representation of the aggressiveness of soils, listed in order of

    increasing aggressiveness (BS 7430:1998):

    Gravelly soils (Least Aggressive)

    Sandy soils

    Silty soils (loam)

    Clays

    Peat and other organic soils

    Made up soils containing cinders (Most Aggressive)

    4-34 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    35/100

    STANDARDS ANDGUIDELINES FORCOMMUNICATIONSITES DISSIMILARMETALS ANDCORROSIONCONTRO

    The least aggressive soils tend to be those having a high resistivity. The resistivity of soil can be

    measured, which provides an indication of corrosiveness under aerated conditions (BS 7430:1998). See

    Performing Soil Resistivity Test on page B-6 for measurement details. Soil with a resistivity below

    2,000 ohm centimeters (cm) is generally considered to be highly corrosive (TIA/EIA-222-F-R2003)

    More details about the aggressiveness of soils can be obtained by measuring the redox (from the words

    reduction and oxidation) potential of the soil, which indicates the risk of corrosion due to the presence

    of anaerobic bacteria (BS 7430:1998). Test equipment required to measure redox potential is

    commercially available. The procedure required to test the redox potential can be found in ISO

    11271:2002(E). A geotechnical firm may be required to measure the redox potential of the soil.

    General guidance on the corrosiveness of some grounding electrode system metals in relation to soil

    composition is given below in Table 4-5(BS 7430:1998). A geotechnical firm may be required to

    determine all of the listed soil parameters.

    TABLE 4-5 CORROSIONRESISTANCEPROPERTIES OFCOMMONGROUNDINGELECTRODESYSTEMMETALS ASRELATED

    TOSOILCOMPOSITION

    Soil Parameter

    Grounding Electrode Metal

    Copper Galvanized Steel

    Austenitic Stainless

    Steel*

    Resistivity (cm)

    < 700 Slightly Reduced Moderately Reduced Slightly Reduced

    700 to 4000 Slightly Reduced Moderately Reduced Generally Unaffected

    > 4000 Generally Unaffected Generally Unaffected Generally Unaffected

    Redox Potential (mV)

    < 200 Moderately Reduced Considerably Reduced Moderately Reduced

    200 to 400 Slightly Reduced Slightly Reduced Generally Unaffected

    > 400 Generally Unaffected Generally Unaffected Generally Unaffected

    Moisture Content (%)

    < 10 Generally Unaffected Generally Unaffected Generally Unaffected

    10 to 80 Slightly Reduced Moderately Reduced Slightly Reduced

    > 80 Slightly Reduced Slightly Reduced Slightly Reduced

    Dissolved

    Salts Moderately Reduced Moderately Reduced Slightly Reduced

    Chlorides Moderately Reduced Moderately Reduced Moderately Reduced

    pH

    Acidic < 6 Moderately Reduced Considerably Reduced Slightly Reduced

    Neutral 6 to 8 Generally Unaffected Generally Unaffected Generally Unaffected

    Alkaline > 8 Slightly Reduced Moderately Reduced Generally Unaffected

    Organic Acids > 8 Considerably Reduced Moderately Reduced Slightly Reduced

    * Austenitic stainless steel shallbe formed from 18% chromium and 8% nickel (18/8 stainless steel), per UL 467-2004, section 9.2.6.Table based on information from BS 7430:1998.

    68P81089E50-B 9/1/05 4-35

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    36/100

    DISSIMILARMETALS ANDCORROSIONCONTROL CHAPTER4: EXTERNALGROUNDING(EARTHING)

    The following general observations can be made from Table 4-5:

    Copper-clad steel or solid copper ground rods are one of the better and commonly used materials

    for grounding electrodes. However, the adverse effect of dissolved salts, organic acids and acid

    soils generally should be noted (BS 7430:1998, clause 11).

    Copper or copper-clad ground rods should not be used in soils where organic acids are present,

    unless protective measures are taken, such as encasing the ground rods in a grounding electrodeencasement material. Organic acids are commonly found in poorly drained and poorly aerated soils.

    See Grounding (Earthing) Electrode Encasement Materials on page 4-27.

    Galvanized ground rods should not be used in soils with a redox potential below 200 mV, unless

    protective measures are taken, such as encasing the ground rods in a grounding electrode

    encasement material. See Grounding (Earthing) Electrode Encasement Materials on page 4-27.

    Galvanized ground rods should not be used in acidic soils with a pH below 6.

    4.5.2 GALVANICCORROSION

    Galvanic corrosion (also called dissimilar metals corrosion) refers to corrosion damage induced when

    two dissimilar metals are electrically connected and coupled through an electrolyte (such as soil). When

    a metal is electrically connected to a dissimilar metal, a difference of potential exists between the two

    metals. If the dissimilar metals are also in contact with a low resistivity soil, a complete circuit will

    exist. Current will flow from one metal to the other due to the electrical connection and return path

    through the soil. This naturally occurring phenomenon is why current is obtained from a battery when

    its terminals are electrically connected to a load (TIA/EIA-222-F-R2003). See Figure 4-26for an

    example of installations with and without galvanic corrosion.

    COPPER NIZEDGROUND

    ROD

    GROUND ROD GROUND ROUND

    ROD ROD

    COPPER PER

    FIGURE 4-26 INSTALLATIONSWITH ANDWITHOUTGALVANICCORROSION

    4-36 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    37/100

    STANDARDS ANDGUIDELINES FORCOMMUNICATIONSITES DISSIMILARMETALS ANDCORROSIONCONTRO

    Metals may be listed in order of their respective potentials; such a list is called a galvanic series. A

    galvanic series of commonly used grounding (earthing) electrode system metals and alloys is given in

    Table 4-6(from TIA/EIA-222-F-R2003 and MIL-HDBK-419A). When a complete circuit exists,

    corrosion occurs on the metal listed higher in the galvanic series. The metal listed higher in the galvanic

    series (anode) is where current exits and travels through the soil toward the metal listed lower on the

    galvanic series (cathode). The galvanic series of commonly used metals and alloys is as follows:

    TABLE 4-6 GALVANICSERIES OFCOMMONMETALS

    Anodic (Active) End

    Magnesium

    Zinc (material used to galvanize steel)

    Aluminum

    Steel, Iron

    Lead, Tin

    Brass, Copper, Bronze

    Silver

    Graphite

    Cathodic (Most Noble) End

    The rate of corrosion mainly depends on the conductivity of the soil and the relative position of the

    metals in the galvanic series. The higher the soil conductivity (low resistivity), and the further apart themetals are in the galvanic series, the faster the rate of corrosion (TIA/EIA-222-F-R2003). To some

    extent, the rate of corrosion also depends on the relative surface areas of the metals (BS 7430:1998 and

    IEEE STD 142-1991). A small anode (such as a galvanized steel guy anchor point) and large cathode

    (such as a copper grounding electrode system) should not be installed; in this case, the total current is

    confined to a small space and the current density is large, therefore, corroding the galvanized steel

    (IEEE STD 142-1991).

    General guidance on the suitability of metals for bonding together with neighboring metals is given

    below in Table 4-7(BS 7430:1998); both metals are assumed to be located in the earth. The bond

    between the neighboring metals could be located above or below ground.

    68P81089E50-B 9/1/05 4-37

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    38/100

    DISSIMILARMETALS ANDCORROSIONCONTROL CHAPTER4: EXTERNALGROUNDING(EARTHING)

    TABLE 4-7 SUITABILITY OFMETALS FORBONDING

    Metal assumed to have the Larger Surface Area

    Electrode metal or item assumed to have the Smaller Surface

    Area

    Steel

    Galvanized

    Steel Copper

    Tinned

    Copper

    Galvanized Steel Suitable Suitable Suitable Suitable

    Steel in Concrete Not Suitable Not Suitable Suitable Suitable

    Galvanized Steel in Concrete Suitable * Suitable Suitable

    Lead Suitable * Suitable Suitable

    Key:

    Suitable = Materials suitable for bonding.

    Not Suitable = Materials not suitable for bonding.

    * = Materials suitable for bonding, but the galvanizing on the smaller surface may suffer.

    This table is based on Table 8 of BS 7430:1998.

    4.5.3 MISCELLANEOUSGENERALINFORMATION

    Galvanized steel is strongly electronegative to copper and steel encased in concrete, therefore,

    careful consideration must be give before galvanized ground rods are used at a site that contains a

    concreted encased electrode. (See BS 7430:1998, clause 11.2 for additional information.) See

    Concrete-Encased Electrodes on page 4-20.

    Steel encased in concrete has a potential similar to that of copper; therefore, may be bonded tocopper or copper-clad ground rods. (See BS 7430:1998 and IEEE STD 142-1991 for additional

    information.)

    4.5.4 METHODSTOHELPREDUCECORROSION

    Listed below are some general requirements and guidelines to help prevent corrosion of the grounding

    (earthing) electrode system and other metallic items at the communications site:

    The same metal shallbe used throughout the grounding electrode system whenever possible.

    Aluminum or copper-clad aluminum grounding conductors shall notbe used (NFPA 70-2005,

    Article 250.64).

    Copper shall not come into incidental contact with galvanized steel.

    Copper shall not come into incidental contact with aluminum.

    Precipitation run-off from copper and copper alloys can attack galvanized parts (BS 6651:1999 and

    IEC 61024-1-2, section 5.2); therefore, bare copper conductors or copper bus bars shall notbe

    installed above galvanized steel, such as a tower, unless the steel is protected against the

    precipitation run-off (IEC 61024-1-2, section 5.2).

    4-38 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    39/100

    STANDARDS ANDGUIDELINES FORCOMMUNICATIONSITES DISSIMILARMETALS ANDCORROSIONCONTRO

    CAUTION

    Extremely fine particles are shed by copper parts, which result in severe corrosivedamage to galvanized parts, even where the copper and galvanized parts are not in

    direct contact (IEC 61024-1-2, section 5.2).

    Where a galvanized tower is not protected against precipitation run-off from copper and copper

    alloys, the tower ground bus bar (TGB) shallbe constructed of tinned copper or other suitable

    material.

    Where tinned conductors or galvanized ground rods are used, care shallbe exercised during

    installation so that surfaces are not damaged. If surfaces of these ground elements are damaged, the

    potential for deterioration from galvanic action increases (ANSI T1.313-2003, section 11.5 and

    ANSI T1.334-2002, section 13.6).

    Exothermically welded joints on galvanized material shall be coated with a zinc-enriched paint to

    prevent corrosion.

    Copper/aluminum joints shallbe avoided wherever possible. In cases where they cannot be

    avoided, the connections shallbe exothermically welded or made using an AL/CU listed bimetallictransition connector (IEC 61024-1-2, section 5.2). Use a listed conductive anti-oxidant compound

    on all mechanical connections (ANSI T1.334-2002, section 9).

    Solid, bare, tinned copper conductor should be used to minimize galvanic corrosion between tower

    legs and other parts of the grounding electrode system (ANSI T1.313-2003, section 10.7).

    Grounding connections to galvanized towers shallbe exothermally welded whenever possible.

    When exothermic welding is not possible, the tower grounding conductor shallbe constructed of

    tinned-copper (IEC 61024-1-2, section 5.2).

    Select appropriate grounding electrode system components using Table 4-5.

    When soil conditions are not favorable, such as highly acidic or alkaline, grounding electrode

    system component corrosion may be reduced by encasing the components in a grounding electrode

    encasement material. See Grounding (Earthing) Electrode Encasement Materials on page 4-27,and BS 7430:1998, section 19.6.1, for additional information.

    When soil conditions are not favorable, such as highly acidic or alkaline, grounding electrode

    system component corrosion may be reduced by installing electrolytic ground rods encased in a

    grounding electrode encasement material. See Grounding (Earthing) Electrode Encasement

    Materials on page 4-27and Electrolytic Ground Rods on page 4-16.

    When soil conditions are not favorable, such as highly acidic or alkaline, the useful life of a copper

    ground rod can be extended by using solid copper ground rods instead of copper-clad rods, if soil

    conditions allow driving of the solid copper rod.

    When soil conditions are not favorable, such as highly acidic or alkaline, the useful life of buried

    grounding conductors can be extended by using larger conductors, such as 70 mm2 csa (#2/0 AWG)

    instead of 35 mm2(#2 AWG).

    Use a listed conductive anti-oxidant compound on all mechanical connections (ANSI T1.334-2002,

    section 9). The anti-oxidant compound shallbe liberally installed between the two metals (see

    Figure 4-27 on page 4-40).

    See Guy Anchor Points on page 4-54for information regarding proper grounding techniques to

    help minimize galvanic corrosion of the guy anchor.

    68P81089E50-B 9/1/05 4-39

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    40/100

    BONDING TO THEEXTERNALGROUNDING(EARTHING) ELECTRODESYSTEM CHAPTER4: EXTERNALGROUNDING(EARTHING)

    4.6 BONDING TO THEEXTERNALGROUNDING(EARTHING)ELECTRODESYSTEM

    4.6.1 REQUIREMENTS

    All below-grade grounding (earthing) electrode system connections shallbe joined using exothermic

    welding or listed irreversible high-compression fittings compressed to a minimum of 13.3 tonnes

    (12 tons) of pressure, or as otherwise required by the specific component manufacturer (ANSI T1.313

    2003, figure 3(a)). Manufacturer requirements shall be followed for all connections. Connectors and

    fitting used shallbe listed for the purpose, for the type of conductor, and for the size and number of

    conductors used.

    All above grade grounding electrode system connections (such as grounding electrode conductor

    connection to ground bus bars and tower legs) shallbe joined using exothermic welding, or listed

    irreversible high-compression fittings compressed to a minimum of 13.3 tonnes (12 tons) of pressure, or

    as otherwise required by the specific component manufacturer (ANSI T1.313-2003, figure 3(a)).

    All above grade bonding connections (such as bonding to ancillary equipment, or bonding coaxial

    ground kits to bus bars) shallbe joined using exothermic welding, listed lugs, listed pressure

    connectors, listed clamps, or other listed means required by the specific component manufacturer.

    Connecting hardware shall be designed for the purpose, for the type of conductor, and for the size and

    number of conductors used. All mechanical connections shall be coated with a listed conductive anti

    oxidant compound. The anti-oxidant compound shall be liberally applied between the two metals (see

    Figure 4-27)(NFPA 70-2005, Article 250.70).

    METALLIC BONDINGAND APPLY ANTIOXIDANTCOMPOUND

    REMOVE PAINT (IF PRESENT)

    SURFACE

    BOLT

    NUT

    GROUND LOCKWASHERLUG

    GROUND BUS BAR

    OR EQUIPMENT SURFACEGROUND LUG

    LOCKWASHER

    FIGURE 4-27 PROPERLOCATION OFWASHER WHENCONNECTINGGROUNDINGLUG

    NOTE: In some instances, exothermic welding may not be possible or may be prohibited by the specificcomponent manufacturer (such as towers or fences); in these cases, other suitable means for bonding is

    allowed.

    4-40 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    41/100

    STANDARDS ANDGUIDELINES FORCOMMUNICATIONSITES BONDING TO THEEXTERNALGROUNDING(EARTHING) ELECTRODESYSTEM

    Connecting hardware shallbe listed for the purpose, for the type of conductor, and for the size and

    number of conductors used. All mechanical connections shall be coated with a listed conductive anti

    oxidant compound (NFPA 70-2005, Article 250.70).

    All exothermic and irreversible compression connections for use on external grounding applications

    shallbe UL 467 listed. Copper connectors shallmaintain minimum 88% conductivity rating.

    Compression systems shallinclude crimped die index and company logo for purposes of inspection.

    Aluminum shall notbe used for connection purposes.

    Bonding shallbe performed so that a suitable and reliable connection exists. The following

    requirements shall be observed when bonding grounding connections:

    Paint, enamel, lacquer and other nonconductive coatings shallbe removed from threads and

    surface areas where connections are made to ensure good electrical continuity (NFPA 70-2005,

    Article 250.12). Use of a star washer does not alleviate the requirement to remove nonconductive

    coatings from attachment surfaces. See Figure 4-27for proper star/lock washer location. Star

    washers should only be used as a lock washer.

    After bonding to a painted or galvanized structure, the area shallbe painted with a zinc-enriched

    paint.

    Exothermic welding is the preferred method for bonding connections to the external groundingelectrode system.

    Two-hole lugs secured with fasteners in both holes are preferred over single-hole lugs. Two-hole

    lugs prevent movement of the lug.

    When connecting ground lugs or compression terminals to ancillary equipment, such as air

    conditioners and vent hoods, a lock washer shallbe placed on the nut side. See Figure 4-27. Sheet

    metal screws and/or self-tapping screws shall notbe used.

    All mechanical connections shallbe coated with a listed conductive anti-oxidant compound (NFPA

    70-2005, Article 250.70, ANSI T1.334-2002, section 9). The anti-oxidant compound shallbe

    liberally installed between the two metals (see Figure 4-27 on page 4-40).

    4.6.2 BONDINGMETHODS

    The following paragraphs describe acceptable methods for bonding to the external grounding (earthing)

    electrode system. Exothermic welding and the use of listed irreversible high-compression fittings are

    the only acceptable methods for below-grade bonding. Other mechanical connection methods shall not

    be used below-grade.

    4.6.2.1 EXOTHERMICWELDING

    Exothermic welding is a method of welding electrical connections without an external heat source, such

    as electricity or gas. The process is based on the reaction of granular metals which when combined,

    produce a molten metal. This reaction, which is completed in seconds, takes place in a crucible. The

    liquid metal flows from the crucible into a mold where it meets the ends of the conductors to be welded.

    The temperature of the molten metal is sufficient to fuse the metal of the conductors, resulting in a

    welded molecular bond. Exothermic welding alloys are available for aluminum, copper, and copper to

    steel connections.

    68P81089E50-B 9/1/05 4-41

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    42/100

    BONDING TO THEEXTERNALGROUNDING(EARTHING) ELECTRODESYSTEM CHAPTER4: EXTERNALGROUNDING(EARTHING)

    WARNING

    To help prevent injury from molten metal or sparks and to reduce the risk of fire, followthe exothermic welding manufacturer's safety warnings and requirements.

    Heavy clothing, work shoes or boots, gloves, and safety glasses shallbe worn when performingexothermic welding,

    Exothermic welding shall notbe performed unless another person capable of rendering first aid is

    present. A suitable fire extinguisher shallbe close by with an attendant during the process.

    Observe the following prerequisites for exothermic welding:

    Follow the manufacturer's recommendations.

    Use the proper molds for the conductors being welded.

    Use the proper weld material for the metals being welded.

    Properly clean all metal parts prior to welding.

    Properly dry all metal parts and molds prior to welding.

    The exothermic welding process is shown in Figure 4-28.

    CRUCIBLE

    MOLD

    MOLD CLAMPED

    TO TOWER

    FIGURE 4-28 EXOTHERMICWELDINGMOLD(LEFT) ANDPROCESS(RIGHT)

    4-42 68P81089E50-B 9/1/05

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    43/100

    STANDARDS ANDGUIDELINES FORCOMMUNICATIONSITES BONDING TO THEEXTERNALGROUNDING(EARTHING) ELECTRODESYSTEM

    GROUND ROD

    PIPE

    EXOTHERMIC WELD

    REBAR

    EXOTHERMIC WELD

    FIGURE 4-29 EXAMPLES OFCOMPLETEDEXOTHERMICWELDS

    4.6.2.2 IRREVERSIBLEHIGHCOMPRESSIONFITTINGS

    WARNING

    Wear safety glasses, hard hat, and steel-toes shoes when working with high-compression fittings.

    When using irreversible high-compression fittings, always use the compression tool recommended by

    the manufacturer in accordance with the instructions provided by the manufacturer. Use fittings made of

    the same material as the materials being bonded to avoid dissimilar metal reactions. See Figure 4-30forexamples of high-compression fittings.

    Use fittings properly sized for the conductors being bonded.

    Use fittings and compression tools rated at 13.3 tonnes (12 tons) of force.

    Use only UL-listed connectors.

    To ensure good contact, clean conductors using a wire brush before crimping.

    Coat all crimped connections with a listed conductive antioxidant compound before crimping.

    68P81089E50-B 9/1/05 4-43

  • 8/12/2019 Chapter 4 Motorola R56!09!01 05

    44/100

    MINIMUMSITEGROUNDING(EARTHING) REQUIREMENTS CHAPTER4: EXTERNALGROUNDING(EARTHING)

    MECHANICAL HYDRAULIC BATTERY-POWERED

    FIGURE 4-30 HIGH-COMPRESSIONCONNECTORS ANDTYPICALCRIMPINGTOOLS

    4.7 MINIMUMSITEGROUNDING(EARTHING) REQUIREMENTS

    This section provides the minimum grounding (earthing) requirements for installing a grounding

    electrode system at a communications site and for bonding site equipment to the grounding electrode

    system. Reasonable attempts shallbe made to achieve the grounding electrode system resistance design

    goal, as defined in Grounding (Earthing) Electrode System Resistance Requirements on page 4-46

    The requirements for installing a typical grounding electrode system are as follows:

    Perform a soil resistivity test at the site as described in Appendix B, Soil Resistivity

    Measurements

    Calculate the resistance of a single ground rod as described in Interpreting Test Results on

    page B-10.

    Determine the resistance requirement of the grounding electrode system, based on the site type

    (Light