charge controller cc611/cc612donar.messe.de/exhibitor/metropolitansolutions/2016/k...emc iec 61326...

6
CC61x_D00xxx_00_D_XXEN_preliminary/04.2015 Charge Controller CC611/CC612 Preliminary datasheet

Upload: others

Post on 08-Mar-2021

9 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Charge Controller CC611/CC612donar.messe.de/exhibitor/metropolitansolutions/2016/K...EMC IEC 61326 Operating temperature -25…+75 C Climatic class acc. to IEC 60721: Stationary use

Preliminary datasheet

CC61x_D00xxx_00_D_XXEN_preliminary/04.2015

Charge Controller CC611/CC612

Preliminary datasheet

Page 2: Charge Controller CC611/CC612donar.messe.de/exhibitor/metropolitansolutions/2016/K...EMC IEC 61326 Operating temperature -25…+75 C Climatic class acc. to IEC 60721: Stationary use

2 CC61x_D00xxx_00_D_XXEN_preliminary/04.2015

Charge Controller CC611/CC612

CC611

Device features• Standard OCPP Implementation

• Full OCPP Remote functionality

• Binary OCPP implementation with band-width optimization and NAT network compatibility

• Smart Grid enabled using standard OCPP functionality

• Local and remote configuration

• Compatible with all electric vehicles on the market

• Optional display support

• Automatic resets

Product descriptionThe Bender charge controller CC611 is the main component of a charging point and is designed for use in wall boxes, street light charging points and common charging stations. For electric vehicles, the charge controller controls the charging outlet socket. It enables a setup that is in accordance with current standards, such as IEC 62196, IEC 61851-1 and IEC 61851-22.

The CC611 is characterized by its compact design and size (114.5 mm x 22.5 mm x 99 mm) that in turn enables intelligent, small and cost effective charging points. To enable the charge controller to communicate, a backend system together with a well-known and trusted communication protocol is required. Given that most backend providers strictly adhere to the OCPP communication protocol, the CC611 is OCPP 1.5 complaint and compatible with all electric vehicles on the market. Integration tests with the charge controller have already been performed with backend software providers, such as Vattenfall, Bosch, NTT, DRIIVZ. The CC611 can be operated as an “always on” system that is always connected to a mobile network. The controller supports 2.5G Edge and 3G UMTS mobile networks. Connectivity for online operation is established using a SIM card. User interaction is facilitated using an RFID card reader and LEDs. Charging is initiated by either holding a valid RFID card close to the reader or remotely by the backend system via OCPP.

In offline operation, the charge controller can optionally allow charging without authorization or it can authorize users based on RFID and a local white list of authorized RFID cards.

Functional descriptionAs well as the CC611, a charging point also consists of a smart digital meter (EMH eHZ), a 12 V power supply to operate the CC611, a relay contactor, which is directly connected to a vehicle socket and an RFID reader. When viewed from its correct mounting position on a cap rail, the CC611 has a total of 18 contacts. The control pilot and proximity contacts connect the CC611 to a type 2 outlet socket, enabling the charge controller to communicate with the vehicle and the cable plug. These contacts allow the CC611 to determine whether a cord has been plugged into the socket (proximity) and to inform the vehicle about the amount of power it can draw (refer to ISO/IEC 61851). To ensure that control pilot com-munication between the vehicle and the charge point is not misinterpreted, the 0 V contact of the charge controller 12 V power supply needs to be at same level as the protective earth (PE) used on the socket. Power flow toward the vehicle is controlled by the contactor (using a signal voltage of up to 30 V), which is itself controlled by the CC611 via a relay in the controller.

The CC611 reads the digital eZH meter readings using an optical reader attached to the charge controller via an RJ11 plug. The optical reader interface is positioned on the back of the meter. The SIM card reader is positioned on the controller front panel, as is the USB interface which is used to configure the charge controller. Optionally it can also be used to apply software updates.

The CC611 facilitates simple user interaction using an RFID reader and a set of LEDs. These are located on a separate PCB, which is attached using a standard RJ45 cable. Optionally an additional display can be attached to this PCB for more detailed user interaction.

In normal operation, the boot-up sequence begins after 12 V is applied to the controller. After boot-up, the system establishes a connection to the backend communication system if configured. When a vehicle is connected to the charge point, the outlet socket automa-tically locks the inserted plug. Charging is initiated by holding an RFID card (registered with the backend system) close to the RFID card reader. After ensuring the vehicle is con-nected and ready to charge, the contactor is then switched on to provide power flow. Once charging has completed and the plug on the vehicle side is disconnected by the user, the charge point socket automatically unlocks the plug on the charge point side.

Page 3: Charge Controller CC611/CC612donar.messe.de/exhibitor/metropolitansolutions/2016/K...EMC IEC 61326 Operating temperature -25…+75 C Climatic class acc. to IEC 60721: Stationary use

CC61x_D00xxx_00_D_XXEN_preliminary/04.2015 3

Charge Controller CC611/CC612

Wiring diagram

EMH eHzSmart meter

ABB Residual current circuit breaker

CP PP

C2 C3 C4

2k22k2

L1

L2

L3

N

PE

12 V DC

C1

A2 A3

L1

L2L3

N

RJ11

RJ45

RFID

Meter

IR mod

ule

kWh

2 4 6 N

1 3 5 N‘

H

L

N

+12 V 0 V

2 4 6 8

1 3 5 7

A1

A2

C2

C3

C1

Mennekes (Type 196521)

Kuster ZSB (S 075-005-001)

Actuator **

Mennekes (Type 30537-A)

Mennekes actuator

(Type 196521)

FCT Group (FXL12S1-4409)

** Di�erent actuators are supported.

0 V

P.3 (+)P.1 (2-ring from actuator)

Optocoupler(cathode)

ANTENNA(Internal/external)

C

D

B1 B4

C1 C4

D1 D4

B

USB 1

SIM

P.3 (-)

A1 A2 A3 A4B1 B2 B3 B4

Optocoupler(cathode)

P.1 (+)

B

C

1

2

3G

CC611/CC612 charge controller

A

A

PPCP

A1 A4

Front

2k2

12 V0 V

Outlet socket

Contactor

USB 2

D4

L1 L2 L3 N

PE

M

P.3

P.1

P.2

-

+

D1 D2 D3 D4

A A

DB B

12 V A1 (Contactor)

Optocoupler(anode)

Optocoupler(anode)

Optocoupler(cathode)

RFID Module

V

Disconnecting switch

C

Sensor (P.2)

P.2 (-)

Yellow wire

Yellow wire

Green wire

Green wire

White wire

Brown wire

Brown wire

Red wire

Page 4: Charge Controller CC611/CC612donar.messe.de/exhibitor/metropolitansolutions/2016/K...EMC IEC 61326 Operating temperature -25…+75 C Climatic class acc. to IEC 60721: Stationary use

4 CC61x_D00xxx_00_D_XXEN_preliminary/04.2015

Charge Controller CC611/CC612

Technical data

Insulation coordination acc. to IEC 60664-1/IEC 60664-3

Rated voltage 12 VOvervoltage category/Pollution degree III/3Rated impulse withstand voltage (CC611) 0.5 kVApplication range ≤ 4000 m above sea level

Supply voltage

Nominal supply voltage US DC 12 VOperating range of the supply voltage DC 0.8…1.2 x USPower consumption without modem < 5 VAPower consumption with modem/short-term peak < 11 VA

Measuring range residual current (CC612 only)

Rated frequency 0…2000 HzMeasuring range ± 300 mA

Response values (Only for CC612)

Residual current IΔn1 6 mAResponse tolerance IΔn1 0…-50 %Residual current IΔn2 30 mA

Response tolerance IΔn2 for:f ≤ 1 kHz 0…-20 %f ≤ 1 kHz -20…+100 %

Restart sequence value:DC 6mA < 3 mAAC/DC 30 mA (rms) for f ≤ 1 kHz < 12 mAAC/DC 30 mA (rms) for f ≤ 1 kHz < 22 mAOperating time tae1 für 1 x IΔn1 < 600 ms

Operating time tae2 (at DC or > 15 Hz) for:1 x IΔn2 < 180 ms2 x IΔn2 < 70 ms5 x IΔn2 < 20 ms

Inputs/outputs and operation

LED 1 greenLED 2 greenLED 3G greenUSB 1 Extension interface (Ethernet, WiFi, …)USB 2 Configuration interfaceSIM card micro SIMControl pilot, proximity and optocoupler input (terminal block A ) input/outputMeter (RJ11 plug) externalRFID interface (RJ45 cable) externalPower supply and optocoupler input (terminal block B) inputPlug lock (terminal block C) input/outputRelay K1/K2 (terminal block D) output

Switching elements

Relay K1 charging contactorRelay K2 configurableSwitching elements 2 x 1 N/O contactsOperating principle N/C operationElectrical service life 100,000 switching cyclesContact data acc. to IEC 60947-5-1: Rated operational voltage 30 V Rated operational current 1 AMinimum contact rating 1 mA at AC/DC ≥ 10 V

Environment/EMC

EMC IEC 61326Operating temperature -25…+75°CClimatic class acc. to IEC 60721: Stationary use (IEC 60721-3-3) 3K5 Transport (IEC 60721-3-2) 2K3 Long-term storage (IEC 60271-3-1) 1K4Classification of mechanical conditions acc. to IEC 60271: Stationary use (IEC 60721-3-3) 3M4 (except condensation and formation of ice) Transport (IEC 60721-3-2) 2M3 Long-term storage (IEC 60271-3-1) 1M3

Connection

Connection type push-wire terminalConnection properties: rigid/flexible 0.2…2.5mm² (AWG 24…12) flexible without ferrule 0.25…2.5mm² (AWG 24…12) flexible with ferrule 0.25…2.5mm² (AWG 24…12)Stripping length 7 mmOpening force 0.5 - 0.6 Nm (4 - 5 Ib-in)Test opening, diameter 2.1 mmRJ 45 RFID readerRJ 11 meter

Other

Operating mode continuous operationDegree of protection IP 30Degree of protection terminals IP 20DIN rail mounting IEC 60715

Page 5: Charge Controller CC611/CC612donar.messe.de/exhibitor/metropolitansolutions/2016/K...EMC IEC 61326 Operating temperature -25…+75 C Climatic class acc. to IEC 60721: Stationary use

CC61x_D00xxx_00_D_XXEN_preliminary/04.2015 5

Charge Controller CC611/CC612

99 22.5 7

114.5

Dimension diagramDimensions in mm

Supply voltage US6 mA sensor Type Art. No.

DC

12 V– CC611-1P3 B 9406 0000

CC612-1P3 B 9406 0001

Type designation Art. No.

RJ45 cable for RFID PCB (lenth 500 mm) B 9406 0100

RFID PCB B 9406 0110

Ordering information

Accessories

99.5

50 RFID moduleRJ 45

Page 6: Charge Controller CC611/CC612donar.messe.de/exhibitor/metropolitansolutions/2016/K...EMC IEC 61326 Operating temperature -25…+75 C Climatic class acc. to IEC 60721: Stationary use

Bender GmbH & Co. KGP.O. Box 1161 • 35301 Gruenberg • GermanyLondorfer Strasse 65 • 35305 Gruenberg • GermanyTel.: +49 6401 807-0 • Fax: +49 6401 807-259E-Mail: [email protected] • www.bender.de

CC61

x_D

00xx

x_00

_D_X

XEN

_pre

limin

ary

/ 04.

2015

/ pd

f / ©

Ben

der G

mbH

& C

o. K

G, G

erm

any

– Su

bjec

t to

chan

ge! T

he s

peci

fied

stan

dard

s ta

ke in

to a

ccou

nt th

e ve

rsio

n th

at w

as v

alid

at t

he ti

me

of p

rintin

g.

BENDER Group