charoong thai wire & cable public company limited · cable type : ctw-thw ( mea type a )...
TRANSCRIPT
C = Packing in coilR = Packing in reel
PRODUCTCODE
SIZEcorexmm2
CHAROONG THAI WIRE & CABLE PUBLIC COMPANY LIMITED
Conductor
CTW-THW
1 x 0.5
1 x 1
1 x 1
1 x 1.5
1 x 1.5
1 x 2.5
1 x 2.5
1 x 4
1 x 4
1 x 6
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50
1 x 70
C04011005
C04011001
C04014001
C04011501
C04014501
C04011502
C04014502
C04011004
C04014004
C04014006
C04014010
C04014016
Nominalcross
sectionalarea
mm2
0.5
1
1
1.5
1.5
2.5
2.5
4
4
6
10
16
25
35
50
70
Number &diameterof wire
No./mm
1/0.80
1/1.13
7/0.40
1/1.38
7/0.50
1/1.78
7/0.67
1/2.25
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
19/1.53
19/1.78
19/2.14
Thicknessof
insulation
mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.9
0.9
0.9
1.1
1.1
1.3
1.3
1.5
1.5
Overalldiameter
mm
3.0
3.3
3.5
3.6
3.8
4.0
4.3
4.8
5.2
5.8
7.2
8.4
10.5
11.5
13.5
15.5
Allowableampacities
Free Air40oC
A
11
16
16
21
21
29
29
39
39
51
70
96
127
157
191
244
Minimuminsulation
resistanceat 70oC
M - km
0.0175
0.0141
0.0135
0.0123
0.0116
0.0102
0.0093
0.0094
0.0085
0.0073
0.0069
0.0057
0.0054
0.0047
0.0046
0.0039
Cableweight
(approx.)
kg/km
11
17
17
22
22
31
31
50
50
75
120
180
290
380
540
720
StandardPacking
m
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
500/R
500/R
Building Wire & Low Voltage Power Cable 11
750 V 70oC PVC INSULATED, SINGLE CORE
Insulation
Building wiring for installationon insulator or in raceway,dry and wet location.
Maximum conductor temperature70oCCircuit Voltage does not exceed750 volts.
TIS 11-2531 TABLE 4
*Testing Voltage:2,500 volts.
Annealed copper, solid or strandedSizes 0.5 mm2 up to 500 mm2
Polyvinyl chloride(Any colour as requested)
C O N S T R U C T I O N A P P L I C A T I O N C L A S S I F I C A T I O N R E F E R E N C E
C04014025
C04014035
C04014050
C04014070
CABLE TYPE : CTW-THW ( MEA TYPE A )
PRODUCTCODE
SIZEcorexmm2
CHAROONG THAI WIRE & CABLE PUBLIC COMPANY LIMITED
Conductor
C = Packing in coilR = Packing in reel
CTW-THW
1 x 95
1 x 120
1 x 150
1 x 185
1 x 240
1 x 300
1 x 400
1 x 500
C04014095
C04014120
C04014150
C04014185
C04014240
C04014300
C04014400
C04014500
Nominalcross
sectionalarea
mm2
95
120
150
185
240
300
400
500
Number &diameterof wire
No./mm
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
61/3.20
Thicknessof
insulation
mm
1.7
1.7
1.9
2.1
2.3
2.5
2.7
3.1
Overalldiameter
mm
18.0
19.5
21.5
24.0
27.0
30.0
33.5
38.0
Allowableampacities
Free Air40oC
A
297
345
397
453
535
617
741
854
Minimuminsulation
resistanceat 70oC
M - km
0.0038
0.0034
0.0034
0.0034
0.0033
0.0032
0.0030
0.0031
Cableweight
(approx.)
kg/km
1,000
1,240
1,520
1,900
2,480
3,100
3,950
5,150
StandardPacking
m
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
12 Building Wire & Low Voltage Power Cable
750 V 70oC PVC INSULATED, SINGLE CORE
Insulation
Building wiring for installationon insulator or in raceway,dry and wet location.
Maximum conductor temperature70oCCircuit Voltage does not exceed750 volts.
TIS 11-2531 TABLE 4
*Testing Voltage:2,500 volts.
Annealed copper, solid or strandedSizes 0.5 mm2 up to 500 mm2
Polyvinyl chloride(Any colour as requested)
C O N S T R U C T I O N A P P L I C A T I O N C L A S S I F I C A T I O N R E F E R E N C E