Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa Tel : Intl +27-31-7646840 Fax : Intl +27-31-7645934 Email :[email protected] How to Create User Isogen Symbols Using Symbols Editor 2 FAQ Question: Is it possible to create User Defined Symbols (SKEY) for Isogen Isometric Drawings? Answer: User defined Symbols can be created for Isogen Isometric Drawings, using a utility called the Symbols Editor (Version 2). In this example we are going to create and add a new Isogen Symbol (SKEY) to the “Coriolis Flow Meter” User Shape as seen below.

Upload: ngodan

Post on 14-Mar-2018

218 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa to Create User Is… ·  · 2013-09-23Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa Tel :

Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa

Tel : Intl +27-31-7646840 Fax : Intl +27-31-7645934 Email :[email protected]

How to Create User Isogen Symbols Using Symbols Editor 2 FAQ

Question:

Is it possible to create User Defined Symbols (SKEY) for Isogen Isometric Drawings? Answer:

User defined Symbols can be created for Isogen Isometric Drawings, using a utility called

the Symbols Editor (Version 2). In this example we are going to create and add a new Isogen Symbol (SKEY) to the “Coriolis Flow Meter” User Shape as seen below.

Page 2: Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa to Create User Is… ·  · 2013-09-23Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa Tel :

In order to create an Isogen User Symbol (SKEY), the Symbols Editor 2 needs to be

accessed from the following directory.

Next, in the Symbols Editor 2, expand the “Instruments” section and select the

“Instrument” group. Next click on the “Symbol” menu and click on “New Symbol” to create a new Instrument Symbol (SKEY) as seen below

Page 3: Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa to Create User Is… ·  · 2013-09-23Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa Tel :

A new SKEY will now need to be assigned to the User Symbol. In this example the SKEY

used stands for “Flow Meter Flanged”. In some cases, if the User SKEY is similar to a default SKEY the “Original Symbol Graphics” can be copied to the new SKEY to be quickly modified. In this case a new SKEY Symbol Graphic will be created from scratch. Click on

the “OK” button as seen below.

Using the Draw tools, the User Defined Symbol (SKEY) can now be drawn into to the

drawing area provided. A preview of the Symbol is also presented at the top right of the

drawing area for reference.

Page 4: Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa to Create User Is… ·  · 2013-09-23Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa Tel :

Using the “Select” drawing tool, Start and End Locations can be moved into the correct

locations. The “Green Dot” marks the Start Location and the “Red Dot” marks the End Location as seen below.

Multiple User Defined Symbols (SKEYS) can be added to this Symbols Library to be used on

any project in CADWorx Plant Professional. Now that the User Defined Symbol (SKEY) has been completed, this Isogen Symbols Library needs to be exported to a format that CADWorx Isogen Style Managers can read. Click on the “File” menu and click on “Export

ISOGEN Symbols” as seen below.

Page 5: Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa to Create User Is… ·  · 2013-09-23Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa Tel :

A name can now be assigned to this User Symbols Library (*.asc) file and save location

directory can now be selected as seen below. It is advised to save this Library file to a directory in the Isogen Style Directory to ensure that this file follows this Style Directory if shared.

The Symbols Library (*.asc) file now needs to be loaded into I-Configure so that when the relevant Isogen Style is used, the User Symbols (SKEYS) are available. In I-Configure, select the relevant “Isogen Style” and click on the “Detail” tab. Expand the

“Supplementary” menu and then expand the “DataFiles” menu. Select the

“ISOGENFiles(1)” menu option and inside this menu, right click on the table and click on “Add Row” as seen below.

Page 6: Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa to Create User Is… ·  · 2013-09-23Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa Tel :

Double click on the “File Type” cell on the added row to add a new data file type. Choose

to add an “ASCII-SYMBOLS” file type as seen below.

Next, double click on the “FilePath” cell on the added row and click on the “Browse” button as seen below.

Browse to the correct location, select the exports Symbols Library (*.asc) file and click on the “Open” button as seen below.

Page 7: Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa to Create User Is… ·  · 2013-09-23Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa Tel :

To accept the selected file path, click on the “OK” button as seen below..

Now that the User Symbols Library file (*.asc) has been loaded, this Isogen Style needs to be “Saved” and “Exported” to a format that can be read by CADWorx Plant Professional as

seen below.

The User Defined SKEY can now be added to the “Isogen Data” menu in the “Component Edit” “Dialogue box, for components already inserted into the model as seen below..

Page 8: Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa to Create User Is… ·  · 2013-09-23Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa Tel :

Alternatively, the User Defined SKEY can be added to the Specification “Project” file so that

this Symbol is adopted every time this component is drawn into the model as seen below.

Once this component is exported to Isogen, the result should be similar to the User

Defined Symbol below.

Page 9: Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa to Create User Is… ·  · 2013-09-23Chempute Software (Pty) Ltd P.O.Box 856, Kloof, 3640, South Africa Tel :

Chempute Software (Durban)

Tel: 031-764 6840 Fax: 031 764 5934

Chempute Software (Johannesburg)

Tel: 011 803 6559 Fax: 011 803 6569

www.chempute.com