chip-scale atomic clockcollaboration xsymmetricom a. rashed, p. vlitas, r.m. garvey xcharles stark...

28
Chip-Scale Atomic Clock Robert Lutwak – Symmetricom Technology Realization Center DARPA MTO Technology Symposium March 5, 2007 San Jose, CA

Upload: others

Post on 10-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

Chip-Scale Atomic Clock

Robert Lutwak – Symmetricom Technology Realization Center

DARPA MTO Technology SymposiumMarch 5, 2007San Jose, CA

Page 2: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

Report Documentation Page Form ApprovedOMB No. 0704-0188

Public reporting burden for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering andmaintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information,including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, ArlingtonVA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to a penalty for failing to comply with a collection of information if itdoes not display a currently valid OMB control number.

1. REPORT DATE 05 MAR 2007

2. REPORT TYPE N/A

3. DATES COVERED -

4. TITLE AND SUBTITLE Chip-Scale Atomic Clock

5a. CONTRACT NUMBER

5b. GRANT NUMBER

5c. PROGRAM ELEMENT NUMBER

6. AUTHOR(S) 5d. PROJECT NUMBER

5e. TASK NUMBER

5f. WORK UNIT NUMBER

7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Symmetricom Technology Realization Center

8. PERFORMING ORGANIZATIONREPORT NUMBER

9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM(S)

11. SPONSOR/MONITOR’S REPORT NUMBER(S)

12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public release, distribution unlimited

13. SUPPLEMENTARY NOTES DARPA Microsystems Technology Symposium held in San Jose, California on March 5-7, 2007.Presentations, The original document contains color images.

14. ABSTRACT

15. SUBJECT TERMS

16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT

UU

18. NUMBEROF PAGES

27

19a. NAME OFRESPONSIBLE PERSON

a. REPORT unclassified

b. ABSTRACT unclassified

c. THIS PAGE unclassified

Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18

Page 3: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

Collaboration

SymmetricomA. Rashed, P. Vlitas, R.M. Garvey

Charles Stark Draper LaboratoryM. Varghese, J. Leblanc, G. Tepolt, and M. Mescher

Sandia National LaboratoriesD. K. Serkland, K.M. Geib, and G.M. Peake

$$$DARPA-MTO Contract No. NBCHC020050

Page 4: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

What is an atomic clock?

Atomic resonance is intrinsically more stable than quartz local oscillator

“Natural” atomic microwave resonance frequency is synthesized from RF LOControl Loop continuously steers LO frequency to atomic resonanceRF output (10 MHz) embodies stability of atomic resonance

Page 5: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

Conventional Atomic Clocks

Active Hydrogen Maser375,000 cm3

100 WattsExcellent short-term stability

Cesium Beam Frequency Standard30,000 cm3

50 WattsExcellent long-term stability/accuracy

Rubidium Oscillator500 cm3

10 WattsCompact and cost-effective

Page 6: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

The Chip-Scale Atomic Clock

DARPA MTO-funded effort to produce accurate timing sources for portable instruments

Time-Sequence Code Acquisition for Secure CommunicationsGPS Direct P(y) Code Acquisition

Key SpecificationsDevice Volume: < 1cm3

Total Power Consumption: < 30 mWStability:

Two orders of magnitude smaller and lower power thancurrent atomic clock technology

11101 hr) 1( -y ×<=τσ

Page 7: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

1 10 100 10001E-3

0.01

0.1

1

10

100

1000

10000

100000

1000000

TCXO

MCXOTMXO

ECXO/EMXO

X-72

Cs

LPRO

Maser

1-D

ay T

ime

Erro

r [µs

]

Energy [W-Hr]

The CSAC Challenge

CSAC

Lower Power&

Better Performance

Page 8: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

Small low-power atomic clocks

8.9 cm

1.8 cm

7.5 cm

X72

Smallest production atomic clockVolume ≈ 125 cm3

Power ≈ 8 WStability < 3x10-11 @ 1 second

CSAC PrototypeMiniature Atomic Clock - “MAC”

3.5 cm

1.0 cm

4 cm

Volume ≈ 16 cm3

Power ≈ 125 mWStability ≈ 3x10-10 @ 1 second

CSAC Objective

Volume ≈ 1 cm3

Power ≈ 30 mWStability < 6x10-10 @ 1 second

Page 9: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

DARPA MTO CSAC Program

Multiple Competitive ContractsSymmetricom/Draper/SandiaNational Institute of Standards and Technology (NIST)/U. of ColoradoTeledyne Scientific/Rockwell Collins/AgilentHoneywellSarnoff/Princeton/Frequency Electronics

Three-Phase Program:Phase-I (2002-2003) – Physics and feasibilityPhase-II (2003-2005) – Intermediate size/power prototypePhase-III (2005-2007) – Design Verification and size/power reductionPhase-IV (?) – Environmental Ruggedization, production engineering,

and System Integration

YOU ARE HERE

Page 10: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

Major Challenges

Physics Package (10 mW)Must be heated to T>75°C to vaporize (alkali metal) atoms– Thermal isolation – Convection, Conduction, Radiation– Overhead head load – Low-power-dissipation VCSEL

Mechanical Robustness– Shock and vibration resistance for handheld (dropped) applications

Microwave System (10 mW)Phase noise at microwave frequency (4.6 GHz) must support Signal/NoiseShort-term stability at τ < τLOOP must support STS objective

Control Systems (10 mW)Short-term stability – Low-noise components, Optimum interrogationLong-term stability – “Independent” stabilization of interrogation environment– Atom density and buffer gas environment, optical power and spectrum

ValueSize, power, stability…long-term stability…environmental stability…ease of integration…cost…

Page 11: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

Low-power Physics Strategy

Filter

Cell

Absorption

Cell

Lamp

Coil

LampExciter

RFSource

Photo-DetectorLamp

Rb-87 Rb-87Rb-85

RF DischargeLamp

Resonance CellIn Microwave

Cavity

Conventional Rb Physics- Requires resonant microwave cavity- RF Discharge lamp (1 Watt)- 3 (2?) cells, ovens, controllers

Coherent Population Trapping (CPT) Physics- High-bandwidth Vertical-Cavity Surface Emitting Laser

(VCSEL)- Microwaves applied directly to VCSEL (No cavity)- Potential for very small oven assembly

Ref. R. Lutwak et. al, Proceedings of the 33rd PTTI

Page 12: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

The 10 mW Physics Package

Tensioned polyimide suspensionMicrofabricated Silicon vapor cellLow-power Vertical-Cavity Surface Emitting Laser (VCSEL)Vacuum-packaged to eliminate convection/conductionOverall Thermal Resistance 7000°C/W

M. Mescher, et. Al., "An Ultra-Low-Power Physics Package for a Chip-Scale Atomic Clock," Proceedings of the 13th International Conference on Solid-State Sensors, Actuators and Microsystems (Transducers '05), Seoul, Korea, June 5-9, 2005, pp. 311-316.

Page 13: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

Physics Package Assembly

Lower Heater/suspension

Upper Heater/suspension

Frame spacer

Photodiode

Resonance cell

Waveplate

Cell spacer

VCSEL

Page 14: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

Physics Package

Page 15: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

Physics Package in LCC

Physics package in LCC

Vacuum sealed

Page 16: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

Physics Package Performance

-4 -2 0 2 4

Detuning [kHz]

γ =1313 Hz

CPT Resonance @ 4.6 GHz

Resonance “Q” = 4x106

Stability vs. Time

Page 17: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

Microwave Synthesizer

TCXO Output at 10 MHzAtomic Interrogation at 4596 MHzFractional-N PLL Modulation via digital control of PLLTuning via digital control of PLL

Resolution: 2x10-12

10.0 MHzTCXO

4596 MHzto Physics

4596 MHzVCO

Tuning

LoopFilter

Err in

Attenuator

TCXO Tuning

MicroController

10 MHzClock Output

Tuning&

Modulation

Fractional-NPLL

18-bit DAC

16-bit DAC

MicrowavePower Adjust

Page 18: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

Control System

Laser Servo - Lock laser wavelength to optical absorption resonance via DC BiasTemperature Servo - Optimize optical power via temperatureClock Servo – Lock local oscillator to CPT resonancePower Servo - Optimize CPT signal amplitude via µWave power

Page 19: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

Control Electronics

Microwave System: 60 mWControl System: 40 mW

Total: 125 mW

Regulators & Passives: 15 mWPhysics: 10 mW

Upper µMetal Housing

Lower µMetal Housing

Main Clock Board

Physics Package

Page 20: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

Typical Prototype Performance

Size ≈ 15 cm3

Power ≈ 125 mWStability ≈ 2-3 x10-10 τ-1/2

Page 21: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

CSAC Prototype on Evaluation Board

Power-OnIndicator

PowerSwitch

ResetButton

LockIndicator

50 Ohm Outputs10 MHz 5 MHz

Analog TuningInput

LockBit

Analog Monitors(Factory-Use Only)

RS-232 on PC Standard DB-9

5 VDC in (5 mm center positive)

Jumper on 3.3 VDCTo CSAC

(for current measurement)

CSAC

Page 22: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

10 MHz Clock Output

Page 23: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

Short-Term Goals

1) Build and Test 10 Prototype Units• Measure long-term aging• Statistical variation of STS, TempCo, aging, retrace, etc.• Deliver to systems integrators and independent testing facilities• Support systems-level demonstrations

2) Reduce Size and Power• Develop smaller physics package• Develop low-power microwave oscillator• Test and incorporate lower-power active components

Page 24: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

Prototype CSACs

SN084 SN087

SN309 SN310 SN312 SN313 SN314

Page 25: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

Short-Term Stability

100 101 102 103 104

1E-12

1E-11

1E-10

1E-9

Ove

rlapp

ing

Alla

n D

evia

tion,

σy(τ

)

Averaging Time, τ

SN084 SN087 SN309 SN310 SN312 SN313 SN314

DARPA Goal

Page 26: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

Evolutionary Path to 30 mW/1 cm3

15 cm3

125 mW

Current Prototype

Tiny Micro-Power

1 cm3

30 mW

3 cm3 (including 0.35 cm3 physics package)30 mW (4.6 GHz Output)50 mW (10.0 MHz Output)

Small Low-Power Prototype

Page 27: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

4 cm3 CSAC

3.8 cm3 (including 0.35 cm3 physics package)30 mW (4.6 GHz Output, no Vreg)60 mW (10.0 MHz Output, Vreg)

Small Low-Power Prototype

4 cm3

Prototype Concept

Mu-metal lid

0.35 cm3 physics

uWave & Analog PCB

Digital PCB

Microprocessor

Mu-metal base

Page 28: Chip-Scale Atomic ClockCollaboration XSymmetricom A. Rashed, P. Vlitas, R.M. Garvey XCharles Stark Draper Laboratory M. Varghese, J. Leblanc, G. Tepolt, and M. Mescher XSandia National

0.35 cm3 Physics Package

First prototype build 11/2006.Demonstrated 85°C operation w/10 mW heater powerFixture development underway