Chromatography Catalog
2013/14
Moss Instruments Co., Ltd.
1
Contents
HPLC Columns ……………………………………………………………………………..3
Chromatographic Column Selection…………………………………………………………..3
How to Guarantee Good Performance and Lifetime……………………………………..….4
HPLC Stationary Phases and Their Applications Range………………………………..….5
Troubleshooting……………………………………………………………………………..….7
Guard Columns Selections……………………………………………………………………9
USP Column Listing and DEAIC Offerings………………………………………………….9
Mos Series HPLC Columns ………………………………………………………………….10
Routine Analysis Column…………………………………………………………………….10
Protein Analytical Columns…………………………………………………………………..20
Dynamic Axial Compression Column………………………………………………………22
Semi-prep/Preparative HPLC Columns……………………………………………………23
JiajieTM Guard Columns……………………………………………………………………..26
Dextrangel Column Special …………………………………………………………………27
Columns for Amino Acids Analysis System………………………………………………..28
HPLC Instruments……………………………………………………………………….…29
Assembly Unit……………………………………………………………………………… 29
P1201 HPLC Pump ………………………………………………………………………….29
P230 HPLC Pump……………………………………………………………………………30
UV1201 UV/VIS Detector…………………………………………………………………….30
UV230+/UV230II UV/Vis Detector……………………………………………………..……31
RI230II Refractive Index Detector…………………………………………………………..32
DAD230+ Diode Array Detector ……………………………………………………………32
2
LU230/LU230II Low-pressure Gradient Unit………………………………………………34
DG230 On-line Degasser…………………………………………………………………..34
ZWII Column Oven………………………………………………………………………….35
AS1201 Auto-Sampler……………………………………………………………………..36
RO230/RO1201 Solvent Manager……………………………………………………….37
P230p Semi-Preparative HPLC Pump…………………………………………………..37
P270 Preparative HPLC Pump………………………………………………………….38
P1000+/P500+ Preparative HPLC Pump……………………………………………….38
P2000+ Preparative HPLC Pump……………………………………………………….39
HPLC System Configurations…………………………………………………………..40
Moss iChrom5100 HPLC System…………………………………………………………40
iChrom5100 Isocratic Systems Configurations…………………………………………40
iChrom5100 Binary High-pressure Gradient System Configurations…………………40
iChrom5100 Quaternary Low-pressure Gradient System Configurations…………...41
P1201 Isocratic Systems Configurations………………………………………………..41
P1201 High-pressure Gradient System Configurations……………………………....42
P230/P230II Isocratic Systems Configurations……………………………………….42
P230/P230II High-pressure Gradient System Configurations………………………43
Semi-prep Isocratic System Configurations …………………………………………..43
Prep. Isocratic System Configurations…………………………………………………44
Semi-prep Gradient System Configurations……………………………………………45
Prep. Gradient System Configurations…………………………………………………46
LU230/LU230II Quaternary Low-pressure Gradient System………………………….47
Amino Acids Analysis System…………………………………………………………48
Mos-AAK Amino Acids Analysis System……………………………………………….48
3
Mos-AAP Amino Acids Analysis System……………………………………………….50
Chromatography Data-processing Workstation…………………………………..52
EC2006 Chromatography Data-processing Workstation ……………………………52
EC2000 Chromatography Data-processing Workstation……………………………53
EC2000 GPC Chromatography Data-processing Workstation…………………….53
EC2000DAD Chromatography Data-processing Workstation……………………..54
Dealers ……………………………………………………………………………...56
HPLC Accessories……….………………………………………………………..…57
Tubing and Connections………………………………………………………………57
Filters……………………………………………………………………………………59
Syringes…………………………………………………………………………………61
Columns Accessories…………………………………………………………………62
Instruments Accessories……………………………………………………………...63
4
HPLC Columns
Chromatographic Column Selection
There is a wide range of packing materials in HPLC, and the selection of them has great influence on the
separation performance, so it is very necessary to know of them for appropriate selection.
Silica and silica-based packings
A. Normal phase chromatography
The stationary phases for normal phase chromatography are usually silica and some polar bonded-phase
functional groups, such as Amino Propyl (NH2, APS), Propyl Nitrile (CN, CPS).
As the Si-OH in the surface of silica and other polar functional groups are highly polar, the sequence of
being separated is in line with their polarity in respective analytes, that is to say, the weaker its polarity,
the quicker being separated.
The mobile phases for normal phase chromatography is much weaker than stationary phases, such as
Hexane, Chloroform, and Methylene Chloride.
B. Reversed phase chromatography
The stationary phases for reversed phase chromatography are silica-based bonded phases with
non-polar functional groups on the surface of the silica.
The mobile phases for reversed phase chromatography are polar mixtures of water or buffered solvents
with methanol or acetonitrile.
The most polar analyte will be first dashed out among the sample, while the less polar ingredient will be
strongly retained.
Typical packings for reversed phase chromatography are C18 (ODS), C8 (MOS), C4 (Buty1), C6H5
(Phenyl).
Polymeric packings
Polymeric packings are mainly polystyrene-divinylbenzene or polymethacrylate,and etc,which can be
used from pH 1-14 as their leading advantage.
Comparing with silica-based C18 packing, these packings are more hydrolphobic; polymeric packings
with large pore are quite efficient to the separation of samples like protein.
The main disadvantage of current polymeric packings is the low column efficiency compared with sili-
ca-based packings.
5
Other inorganic packings
Other HPLC columns with inorganic packings have been commercialized, but they are limited for special
use because of unique property, for example, graphitic carbon is gradually becoming a member of re-
versed phase packings. Separation with this kind of packings is different from silica-based alkyl-bonded
phases, for the graphite surface is the retention base, you don’t need any other surface modifications.
Normally, this column packing has stronger retention than alkyl-bonded silica or porous polymeric pack-
ings. Graphitic carbon can separate some geometrical isomer, and it can’t be dissolved by the HPLC
mobile phase, so it can be used in any pH range and temperature. Alumina can also be used in HPLC,
first, it has strong rigidity and could be made into stable chromatographic column bed; second, it can be
used with the mobile phase at pH 12. But alumina hasn’t been widely applied for its application area is
limited by the strong interactions with basic compounds. The new-type zirconia-based packings can also
be used in HPLC, but the only commercializd packing is polymer-coated porous microspherical zirconia,
which exihits at the environment of pH 1-14 and the highest temperature 100℃. As zirconia-based
packings have been studied for recent years, facing experiment difficulties, so their important purposes
and advantages are in process.
How to Guarantee Good Performance and Lifetime?
◇Read columns user manual carefully
◇Use well packed columns
◇Reduce pressure pulsation to avoid mechanical and thermal impact
◇Make use of guard column and on-line filter
◇Wash columns with strong solvents often
◇Completely filter samples and mobile phases, avoid impurity atoms and strong reserved com-
ponents
◇Use stable stationary phases (C18 is the most stable stationary phase)
◇Use organic buffer solvents on the operation of pH ranging 6-8
◇The best use temperature for columns is lower than 40℃
◇Silica-based columns should keep their mobile phase pH ranging 2.0-8.0
◇Add 200ppm NaN3 in water mobile phases and buffer solvents
◇If there are buffer solvents in the mobile phases, pay attention to use 95:5 water and organic
solvent to filter, and the organic solvent can’t less than 5%.
◇For storage or stay for a night, rinse out salt and buffer solvent and reserve with pure organic
mobile phase. (Ethylic-nitrile is best)
6
HPLC Stationary Phases and Their Applications Range
Common
Name Alternative
Functional
Group
Normal
Phase
Reverse
Phase
Ion
Exchange Application
Silica SiO2 -OH √
Non-polar and moder-
ately polar organic
compounds.
SAS C1 -(CH3)3 √
Least retentive of all
alkyl group bonded
phases for non-polar
solutes.
Typically used for
moderately polar and
multi-functional com-
pounds.
Butyl C4 -C4H9 √
Separation of peptides
and proteins. Shorter
retention than C8, C18.
MOS C8,Octyl -C8H17 √
Less retentive than
C18; normally used for
small peptides and
proteins, pharmaceuti-
cals, steroids, envi-
ronmental samples.
ODS C18 -C18H37 √
Most retentive of the
alkyl-bonded phases.
Used widely for
pharmaceuticals, ster-
oids, fatty acids,
phthalates, environ-
mental etc.
CPS
CN,Cyano,
(propylnitrile)
-(CH2)3CN √ √
Unique selectivity for
polar compounds, more
suitable than base sili-
ca for normal phase
gradient separations.
When used in reversed
phase,the selectivity is
different to that of the
C8 and C18 phases.
Useful for a wide range
of pharmaceutical ap-
plications and for mix-
tures of very different
7
solutes.
APS
NH2,
Aminopropyl
-(CH2)3NH2 √ √ √
HILIC: Carbohydrate
analysis and other po-
lar compounds. Weak
anion exchanger, ani-
ons and organic acids.
Normal Phase: Alterna-
tive selectivity to silica.
Good for aromatics.
Phenyl C6H5 -(CH2)C6H5 √
Aromatic compounds
and moderately polar
compounds.
Diol
-(CH2)2O
CH2(CH2O
H)2
√ √
Reversed Phase: Pro-
teins, peptides.
Normal Phase: similar
selectivity to silica, but
less polar.
SCX Strong Cation
Exchanger -RSO3H- √
Organic bases.
SAX
Anion Ex-
changer
Polyeth-
leneimine
(PEI)
-(CH2CH2N
H-)n
Organic acids, nucleo-
tides and oligonucleo-
tides.
8
Troubleshooting
Analysis on bad reservation and separation reproducibility
Causes on peak tailing
◇Problems of the process of packing the columns themselves, sieve plate jam or packings col-
lapse.
◇Pollutions on the column head
◇Overloading samples
◇Improper sample solvents
◇Effect beyond columns
◇Chemical or twice reservation effect (Si-OH)
Problems Causes Representations
Differences among different
columns
Different packings and bonded
phases
Retension factor(k), separation
factor(α)
Columns change in the
process of use
Column beds break,
Bonded phase lost,
Silica solved
Strong retension components
stack
Column performance(N)
Retension factor(k), separatin fac-
tor(α),
Column performance(N)
Retension factor(k), column per-
formance(N)
Extra-column effect Systems differences,Syringe
volume is too big, The tubing
volume between injector, col-
umn and detector is too big,
Flow cell volume is too big,
Dead volume of adapter is too
big.
Column performance(N)
Change on separation ef-
fect
Change of the mobile phases
components;
Change of flow rate;
Change of temperature
Retension factor(k), small change
of column performance(N)
Retension factor(k), separation
factor(α)
Retension factor(k), small change
of column performance(N)
Low equilibration Not enough re-equilibration time Retension factor(k), small change
of column performance(N)
Overload of the column Too much samples Retension factor(k), colulmn er-
formance(N)
9
◇Lack of buffers or improper buffers
◇Heavy metal pollutions
How to solve peak tailing problems
A. Peak tailing problems concerned with chemistry
1. Add 30mM triethylamine (for basic compounds) or acetic-amine (for acid compounds), or add ace-
tic-triethylamine for unknowns into mobile phase.
2. If it is still tailing, replace the acetic-triethylamine with dimethyl-octyl amine
3. Make the injection volume less than 1μg.
B. Peak tailing problems concerned with columns
1. Reversed columns can be flushed with 20 times volume solvents: 96%CH2Cl2, 4% CH3OH (methanol),
and 1%NH4OH; normal columns can be flushed with CH3OH (methanol).
2. Use of guard columns.
C. Peak tailing and widening concerned with HPLC system
1. Syringe volume is too big (normally ≤ 25μL )
2. The tubing volume between injector, column and detector is too big (best for tube < 20cm, ID0.007”).
3. The flow cell volume of the detector is too big.
How to store columns
Make the mobile phases in accordance with the actual use to avoid the microorganism produced by
buffered solvents and aqueous mobile phases, or add 200ppm NaN3 to restrain the growth of the bacteria
(Pay attention to its toxicity and potentially explosibility); or add 20% organic modifier in mobile phases
can also restrain the bacteria, and the reconstructive solvents can be helpful to mobile phase degassing.
Use 100% organic solvents (Ethylic-nitrile is best) to store columns instead of buffered solvents.
Columns flushed with buffered solvents should be purged with 15-20 times volume organic mobile
phases without buffers, and then store with 100% organic solvents.
Don’t flush columns bonded C18 with pure water.
Screw with end caps for the both ends of the columns to avoid the packing hardened cracked.
10
Guard Columns Selections
As a regular question of chromatography workers, how to select guard columns but not affect separation
analysis always made them think. Usually, make sure the sample is clean before selecting guard column.
For most analytical workers, one 1cm length guard column can fully function for guard use. If samples are
very dirty or often need to change the 1cm guard column, then chose 2cm or 3cm length guard columns.
The longer the guard column, the more packing in, and the less chance the pollutants enter the column,
while the longer of the retention time. Generally speaking, the inside diameter of guard column should be
same with the chromatographic column.
Ways of packing the guard columns are also very important. At present, there is a way of membrane
packing with a very simple and convenient application process, and can be installed in the lab. But the
biggest shortcoming is not economical, especially for China’s current status, for the expense for only one
time use is comparatively high. In addition, the guard columns with the way of membrane have limited
packing materials and provide limited guard function; as these columns are short because of the few
packing materials, they have little effect on retention time of the analytical samples.
Other guard columns are curtate columns, and there are three designs: direct-connection, finger-tight,
and integral. The integral design is that the manufacturers install the guard column together with analyt-
ical column directly according to the order; it’s very convenient but can’t be modified. Direct–connection
design is that the guard columns can be connected to any kind of analytical columns and installed any-
time by workers, besides; the chromatographic workers can select different guard column length in ac-
cordance with samples. The finger-tight design and the direct-connection design are same in structure;
the only difference is it can be installed by hands instead of wrench. In addition, from the structure point of
view, some guard columns can replace their drop-in cartridges, while some others cannot. At present,
most guard columns can replace their drop-in cartridges to reduce the guard columns cost.
Most people select guard column packings in accordance with analytical column packings, normally
speaking, they are same. But they aren’t necessarily same according to actual analytical work.
The principle of selecting guard column is: on the precondition of meeting analysis and separation, select
the shortest guard column and chose packings with the least reservation to samples.
11
Moss Series HPLC Columns
Jinhua Moss Analytical Instruments Co., Ltd (JMAIC) is domestic biggest supplier in the field of HPLC
columns, which almost takes up half of columns sales of the whole country, meanwhile, its products also
export to USA, UK, India and other countries and leads a significant role at home and abroad.
JMAIC has a long-term and good relationship with many world famous manufacturers of packings and
columns, so we can meet the needs of a great deal chromatographic workers with good quality and low
price.
To be guaranteed quality, our company is always running under the required of ISO9001:2000 System.
Test every batch of packings before using, and to be strictly with quality control for every column before
leaving factory. Help customers to solve the problem during using by our application lab. Now we have
setted up a good and healthy company image among the customers by our continuous efforts in the re-
cent years.
Our company provides a lot of brands and types packings for analytical columns, fast analytical columns,
gel columns, protein analytical columns, amino analytical columns, guard columns, semi-prep and pre-
parative columns.
Routine Analysis Column
SinoChrom HPLC Columns
SinoChrom ODS-AP
◇ High coverage and exhaustive end-capping
◇ Exceptional batch-to-batch reproducibility
◇ Enhanced mechanical stability
SinoChrom ODS-AP packing featuring maximum surface coverage are the ideal choice for a wide variety
of organic compounds.Carefully controlled full end-capping leads to optimal performance with acidic,
basic and chelating compounds.
12
SinoChrom C8
◇ Recommended for higher hydrophobic samples
◇ Versatile reverse phase column
SinoChrom C8 packing materials are bonded with octyl groups and are fully end-capped. They are rec-
ommended for compounds which are too strongly retained on C18 phases.300 Å materials are widely
used for larger molecules with higher hydrophobicity.
SinoChrom C4
◇ Recommended for biological separation
◇ Quick separation of wide hydrophobicity samples
SinoChrom C4 packing materials are bonded with butyl groups and show moderate hydrophobicity. 300A
materials are suited for the separation of peptides and proteins. Especially, larger pore silica with less
surface area is used to avoid denaturation of proteins. The phases are also useful for separating com-
ponents within a wide range of hydrophobicity in one shot.
SinoChrom ODS-BP
◇ Suitable for hydrophilic compounds separation
◇ Strong retention in aqueous condition
◇ Long lifetime in aqueous eluents
◇ Different selectivity from ODS-AP
SinoChrom ODS-BP phases are designed to show extended selectivity for hydrophilic and polar com-
pounds which are either not or poorly retained on other phases. A proprietary modification technique
avoids the matting-down effect of the C18 chains which conventional ODS-phases show at high water
contents in the mobile phase, even if pure water is used, Typical applications are separations of biomol-
ecules and metabolites such as oligosaccharides, amino acids, small peptides, nucleotides and organic
acids.
SinoChrom ODS-BP phases show stable base lines and high sensitivity even under neutral pH conditions
and without buffer or counter-ion additives, which makes them appear especially suited for hyphenated
techniques like LC-MS, where such additives disturb the detect.
In addition, cause of SinoChrom ODS-BP packing is a kind of exhaustive end-capping packings, it has
the same selectivity as routine ODS stationary phase while analysis hydrophilia chemical compounds
with classic reverse phase mobile phase.
SinoChrom APS
13
◇ Useful in both normal and reverse phase
◇ Recommended for basic compounds separation
◇ Useful as a support of special modification
SinoChrom APS packing materials are bonded with amino-propyl silane using our ultra pure spherical
silica gel as base material, Depending on the choice of the eluent, it can both be used under normal and
reversed phase mode. Especially, it is useful for saccharide separation using acetonitrile / water, the
phase is also recommended for the separation of basic compounds under normal phase conditions,
which could not be separated using unmodified silica gel. Simple eluents such as hexane / ethyl acetate
or chloroform / methanol are used for the separation without any polar sovent additives. The amine func-
tionality provides higher reactivity and is useful as a support of special modifications such as chiral
phases.
SinoChrom P-ODS
SinoChrom P-ODS is wide range in application. It can absolutely meet with analysis about the samples of
biochemistry, proteins, nucleic acid and so on.
SinoChrom P-NH2
SinoChrom P-NH2 is appropriate for the analysis and separation about the samples of monosaccharide,
disaccharide, sugar alcohol and other saccharides.
SinoChrom P-ODS and SinoChrom P-NH2 are the packing materials based on polymer, which compared
with those materials based on silica are at a wide range of pH 1-14. Recommended used for bad analysis
conditios, which will be a long lifetime.
SinoChrom packings parameters
Phase Particle Size(μm) Surface Area(m2/g) Pore Size(Å) Carbon Load End-capped
ODS-BP 5,10 300 120 15% Yes
ODS-AP 5,10 300 120 17% Yes
C8 5,10 300 120 11% Yes
C4 5,10 300 120 8% Yes
APS 5,10 300 120 4% Yes
Si60 5,10 450 60 - -
14
SinoChrom Columns Ordering Guide
Descriptions Particle size(μm) Specification (mm) Part No. List Price (USD )
SinoChrom ODS-BP 5 4.6 x 150 31110004
5 4.6 x 200 31110005
5 4.6 x 250 31110006
5 5.0 x 150 31110404
10 4.6 x 150 31110569
10 4.6 x 200 31110428
10 4.6 x 250 31110008
SinoChrom ODS-AP 5 4.6 x 150 31110001
5 4.6 x 200 31110002
5 4.6 x 250 31110003
5 5.0 x 150 31110648
10 4.6 x 150 31110151
10 4.6 x 200 31110649
10 4.6 x 250 31110650
SinoChrom C8 5 4.6 x 150 31110388
5 4.6 x 200 31110124
5 4.6 x 250 31110125
5 5.0 x 150 31110651
10 4.6 x 150 31110652
10 4.6 x 200 31110653
10 4.6 x 250 31110439
SinoChrom C4 5 4.6 x 150 31110654
5 4.6 x 200 31110655
5 4.6 x 250 31110531
10 4.6 x 150 31110656
10 4.6 x 200 31110657
10 4.6 x 250 31110658
SinoChrom APS 5 4.6 x 150 31110564
5 4.6 x 200 31110664
5 4.6 x 250 31110135
15
10 4.6 x 150 31110665
10 4.6 x 200 31110666
10 4.6 x 250 31110464
SinoChrom Si60 5 4.6 x 150 31110349
5 4.6 x 200 31110351
5 4.6 x 250 31110136
10 4.6 x 150 31110667
10 4.6 x 200 31110668
10 4.6 x 250 31110669
SinoChrom P-ODS 10 4.6 x 150 31110670
10 4.6 x 200 31110671
10 4.6 x 250 31110360
SinoChrom P-NH2 10 4.6 x 150 31110559
10 4.6 x 200 31110672
10 4.6 x 250 31110560
Hypersil HPLC Columns
Hypersil packings parameters
Phase Particle Size(μm) Surface Area(m2/g) Pore Size(Å) Carbon Load End-capped
ODS2 5 220 80 11% Yes
C8 5,10 170 120 6.5% Yes
CN 5,10 170 120 4.0% Yes
NH2 5,10 170 120 1.9% Yes
SiO2 5,10 170 120 - -
C1 5,10 170 120 2.5% Yes
C6H5 5,10 170 120 5.0% Yes
SAX 5,10 170 120 2.5% Yes
ODS 5,10 170 120 10% Yes
16
Moss Hypersil Columns Ordering Guide
Descriptions Particle size(μm) Specification (mm) Part No. List Price (USD )
Hypersil ODS2 5 2.1 x 150 31110393
5 4.0 x 150 31110420
5 4.0 x 200 31110171
5 4.0 x 250 31110137
5 4.0 x 300 31110141
5 4.6 x 150 31110027
5 4.6 x 200 31110028
5 4.6 x 250 31110029
5 4.6 x 300 31110030
5 5.0 x 150 31110436
5 5.0 x 200 31110432
5 5.0 x 250 31110332
5 5.0 x 300 31110031
Hypersil ODS (C18) 5 2.1 x 150 31110516
5 4.0 x 150 31110382
5 4.0 x 200 31110475
5 4.0 x 250 31110368
5 4.0 x 300 31110509
5 4.6 x 150 31110018
5 4.6 x 200 31110019
5 4.6 x 250 31110020
5 4.6 x 300 31110021
5 5.0 x 150 31110725
5 5.0 x 200 31110387
5 5.0 x 250 31110551
5 5.0 x 300 31110726
10 2.1 x 150 31110727
10 4.0 x 150 31110728
10 4.0 x 200 31110729
10 4.0 x 250 31110730
10 4.0 x 300 31110731
10 4.6 x 150 31110023
10 4.6 x 200 31110024
10 4.6 x 250 31110025
10 4.6 x 300 31110026
10 5.0 x 150 31110732
10 5.0 x 200 31110733
10 5.0 x 250 31110734
10 5.0 x 300 31110735
Hypersil C8 5 4.0 x 150 31110470
5 4.0 x 200 31110736
17
5 4.0 x 250 31110146
5 4.0 x 300 31110737
5 4.6 x 150 31110032
5 4.6 x 200 31110033
5 4.6 x 250 31110034
5 4.6 x 300 31110140
5 5.0 x 150 31110738
5 5.0 x 200 31110739
5 5.0 x 250 31110740
5 5.0 x 300 31110741
10 4.6 x 150 31110035
10 4.6 x 200 31110036
10 4.6 x 250 31110224
10 4.6 x 300 31110742
Hypersil CN 5 4.0 x 150 31110743
5 4.0 x 200 31110744
5 4.0 x 250 31110566
5 4.0 x 300 31110745
5 4.6 x 150 31110039
5 4.6 x 200 31110040
5 4.6 x 250 31110041
5 4.6 x 300 31110357
10 4.6 x 150 31110180
10 4.6 x 200 31110419
10 4.6 x 250 31110746
10 4.6 x 300 31110747
Hypersil NH2 5 4.0 x 150 31110748
5 4.0 x 200 31110749
5 4.0 x 250 31110496
5 4.0 x 300 31110178
5 4.6 x 150 31110042
5 4.6 x 200 31110043
5 4.6 x 250 31110044
5 4.6 x 300 31110045
5 5.0 x 150 31110750
5 5.0 x 200 31110751
5 5.0 x 250 31110752
5 5.0 x 300 31110753
10 4.0 x 150 31110754
10 4.0 x 200 31110755
10 4.0 x 250 31110756
10 4.0 x 300 31110196
10 4.6 x 150 31110421
10 4.6 x 200 31110046
10 4.6 x 250 31110047
10 4.6 x 300 31110331
18
Hypersil SiO2 5 4.0 x 150 31110461
5 4.0 x 200 31110476
5 4.0 x 250 31110399
5 4.0 x 300 31110565
5 4.6 x 150 31110049
5 4.6 x 200 31110050
5 4.6 x 250 31110051
5 4.6 x 300 31110376
5 5.0 x 150 31110757
5 5.0 x 200 31110208
5 5.0 x 250 31110327
5 5.0 x 300 31110758
10 4.0 x 150 31110759
10 4.0 x 200 31110760
10 4.0 x 250 31110761
10 4.0 x 300 31110366
10 4.6 x 150 31110403
10 4.6 x 200 31110429
10 4.6 x 250 31110177
10 4.6 x 300 31110762
Hypersil C1 5 4.6 x 150 31110335
5 4.6 x 200 31110330
5 4.6 x 250 31110145
5 4.6 x 300 31110763
10 4.6 x 150 31110764
10 4.6 x 200 31110765
10 4.6 x 250 31110766
10 4.6 x 300 31110767
Hypersil C6H5 5 4.0 x 150 31110326
5 4.0 x 200 31110768
5 4.0 x 250 31110588
5 4.0 x 300 31110510
5 4.6 x 150 31110342
5 4.6 x 200 31110409
5 4.6 x 250 31110038
5 4.6 x 300 31110222
10 4.0 x 150 31110384
10 4.0 x 200 31110769
10 4.0 x 250 31110770
10 4.0 x 300 31110642
10 4.6 x 150 31110153
10 4.6 x 200 31110771
10 4.6 x 250 31110363
10 4.6 x 300 31110478
Hypersil SAX 5 4.6 x 150 31110211
5 4.6 x 200 31110333
19
5 4.6 x 250 31110048
10 4.6 x 150 31110579
Hypersil C4 10 4.6 x 250 31110232
5 4.6 x 150 31110238
5 4.6 x 200 31110037
5 4.6 x 250 31110119
Hypersil BDS Packing
◇ Hypersil BDS C18
◇ Hypersil BDS C8
◇ Hypersil BDS CN
◇ Hypersil BDS C6H5
The Characteristic of Hypersil BDS Packing
◇ Outstanding peak shape when analysis alkaline compound
◇ Long lifetime of the column
◇ Better stability
◇ As analysising alkaline compounds, outstanding peak shape when analysis acid compounds
and neutral compounds
Hypersil BDS packings parameters
Phase Particle Size(μm) Surface Area(m2/g) Pore Size(Å) Carbon Load End-capped
C18 3, 5 170 130 11% Yes
C8 3, 5 170 120 7.0% Yes
CN 5 170 120 4.0% Yes
C6H5 5 170 120 5.0% Yes
20
Hypersil BDS Columns Ordering Guide
Descriptions Particle size(μm) Specification (mm) Part No. List Price (USD )
Hypersil BDS C18 5 2.1 x 150 31110350
5 4.0 x 150 31110408
5 4.0 x 200 31110148
5 4.0 x 250 31110369
5 4.0 x 300 31110345
5 4.6 x 150 31110053
5 4.6 x 200 31110054
5 4.6 x 250 31110055
5 4.6 x 300 31110056
5 5.0 x 150 31110489
5 5.0 x 200 31110328
5 5.0 x 250 31110433
5 5.0 x 300 31110772
Hypersil BDS C8 5 4.0 x 150 31110780
5 4.0 x 200 31110781
5 4.0 x 250 31110582
5 4.0 x 300 31110782
5 4.6 x 150 31110060
5 4.6 x 200 31110061
5 4.6 x 250 31110156
5 4.6 x 300 31110783
Hypersil BDS CN 5 4.6 x 150 31110487
5 4.6 x 200 31110169
5 4.6 x 250 31110133
5 4.6 x 300 31110784
Hypersil BDS C6H5 5 4.6 x 150 31110118
21
5 4.6 x 200 31110168
5 4.6 x 250 31110377
5 4.6 x 300 31110789
BETASIL Packings
◇ With highly pure base deactivated silica, offer outstanding peak shape.
◇ High specific surface area and high covered for bonded phase.
◇ With outstanding efficiency, and high theoretical plates.
◇ Strong retention and can be used for analysis of pole-strength compounds.
BETASIL packings parameters
Phase Particle Size(μm) Pore Size(Å) Carbon Load End-capped
BETASIL C18 5,10 100 20% Yes
BETASIL C8 5,10 100 12% Yes
BETASIL C6H5 5 100 11% Yes
BETASIL CN 5 100 6% Yes
BETASIL SiO2 5 100 —— ——
BETASIL Columns Ordering Guide
Descriptions Particle size(μm) Specification (mm) Part No. List Price (USD )
BETASIL C18 5 4.6 x 100 31110804
5 4.6 x 150 31110086
5 4.6 x 200 31110126
5 4.6 x 250 31110087
YWG PACKINGS (Domestic Packings)
YWG Columns Ordering Guide
Descriptions Particle size(μm) Specification (mm) Part No. List Price (USD )
YWG C18 10 4.0 x 150 31110805
10 4.0 x 200 31110498
10 4.0 x 250 31110556
22
10 4.0 x 300 31110806
10 4.6 x 150 31110011
10 4.6 x 200 31110226
10 4.6 x 250 31110012
10 4.6 x 300 31110013
10 5.0 x 150 31110807
10 5.0 x 200 31110105
10 5.0 x 250 31110808
10 5.0 x 300 31110809
Columns used for analysis of protein
Hypersil packings
◇ Hypersil 300 Å C4
Can be used to analysis hydrophobic Oligo-peptide or macromolecular polypeptide.
◇ Hypersil 300 Å C4
Can be used to analysis hydrophobic Oligo-peptide or macromolecular polypeptide.
◇ Hypersil 300 Å C8
Can be used to analysis hydrophilic or weak hydrophobic Oligo-peptide and protein, or
enzymatic hydrolyzing. Also can be used to analysis various kinds of natural or com-
pound Oligo-peptide.
Hypersil 300Å packings parameters
Phase Particle Size(μm) Surface Area(m2/g) Pore Size(Å) Carbon Load End-capped
C8 5,10 80 300 3.3% Yes
C4 5,10 80 300 2.0% Yes
Moss Hypersil 300Å Columns Ordering Guide
Descriptions Particle size(μm) Specification (mm) Part No. List Price (USD )
Hypersil 300 Å C8 5 4.6 x 150 31110324
5 4.6 x 200 31110412
5 4.6 x 250 31110121
5 4.6 x 300 31110359
23
10 4.6 x 150 31110790
10 4.6 x 200 31110791
10 4.6 x 250 31110518
10 4.6 x 300 31110792
Hypersil 300 Å C4 5 4.6 x 150 31110354
5 4.6 x 200 31110063
5 4.6 x 250 31110064
5 4.6 x 300 31110453
10 4.6 x 150 31110793
10 4.6 x 200 31110355
10 4.6 x 250 31110065
10 4.6 x 300 31110794
SinoChrom Packings
SinoChrom 300Å packings parameters
Phase Particle Size(μm) Surface Area(m2/g) Pore Size(Å) Carbon Load End-capped
ODS-AP 5,10 100 300 9.0% Yes
C8 5,10 100 300 5.0% Yes
C4 5,10 100 300 3.0% Yes
SinoChrom Columns Ordering Guide
Descriptions Particle size(μm) Specification (mm) Part No. List Price (USD )
SinoChrom 300 Å
ODS-AP 5 4.6 x 150 31110116
5 4.6 x 200 31110373
5 4.6 x 250 31110117
10 4.6 x 150 31110536
10 4.6 x 200 31110673
10 4.6 x 250 31110362
SinoChrom 300 Å C8 5 4.6 x 150 31110448
5 4.6 x 200 31110674
5 4.6 x 250 31110234
10 4.6 x 150 31110675
10 4.6 x 200 31110676
10 4.6 x 250 31110677
SinoChrom 300 Å C4 5 4.6 x 150 31110447
5 4.6 x 200 31110678
5 4.6 x 250 31110010
10 4.6 x 150 31110679
24
10 4.6 x 200 31110680
10 4.6 x 250 31110681
Descriptions DAC-50 DAC-80 DAC-100 DAC-150
ID φ 50mm 80mm 100mm 150mm
High of Packed bed 0~400mm
Material of Hardware Kit 316L S. S.
DAC Dynamic Axial Compression Column Ordering Guide
Descriptions
Moss DAC-50 Dynamic Axial Compression Column
Moss DAC-80 Dynamic Axial Compression Column
Moss DAC-100 Dynamic Axial Compression Column
Moss DAC-150 Dynamic Axial Compression Column
Can be customed as required
Semi-prep/Preparative HPLC Columns
The preparative columns packed with high-pressure homogenate
tech have high stable column bed, which makes the preparative
columns have same performance with analytical columns, and
DAC Dynamic Axial Compression Column
Moss DAC Series are new products we launched to the
market used for analysis Industrial Chromatography. To
meet different scale of preparative needing of commercial
proess. Extensive used for the industrial chromatography
systems to analysis natural product, synthetic drugs,
protein and polypeptide bio-pharmaceutical.
25
realize high efficiency separation.
SinoChrom Packings
Ordering Guide
Descriptions Particle size (μm) Specification (mm) Part No. List Price (USD )
SinoChrom ODS-BP 5 10 x 150 31110866
5 10 x 200 31110867
5 10 x 250 31110379
5 10 x 300 31110868
5 20 x 150 31110869
5 20 x 200 31110870
5 20 x 250 31110385
5 20 x 300 31110871
SinoChrom ODS-AP 5 10 x 150 31110611
5 10 x 200 31110872
5 10 x 250 31110873
5 10 x 300 31110874
5 20 x 150 31110875
5 20 x 200 31110876
5 20 x 250 31110877
5 20 x 300 31110878
SinoChrom ODS-BP 10 10 x 150 31110687
10 10 x 200 31110389
10 10 x 250 31110110
10 10 x 300 31110176
10 20 x 150 31110395
10 20 x 200 31110231
10 20 x 250 31110111
10 20 x 300 31110356
SinoChrom ODS-BP 15 10 x 250 31110467
15 20 x 250 31110468
15 30 x 250 31110688
15 40 x 250 31110689
SinoChrom ODS-AP 10 10 x 150 31110692
10 10 x 200 31110693
10 10 x 250 31110573
10 10 x 300 31110444
10 20 x 150 31110694
10 20 x 200 31110695
10 20 x 250 31110172
10 20 x 300 31110101001
26
SinoChrom ODS-AP 15 10 x 250 31110467
15 20 x 250 31110468
15 30 x 250 31110696
15 40 x 250 31110697
SinoChrom C8 10 10 x 250 31110700
10 20 x 250 31110701
10 30 x 250 31110702
15 40 x 250 31110703
20 40 x 250 31110705
SinoChrom C4 10 10 x 250 31110707
10 20 x 250 31110708
10 30 x 250 31110709
15 40 x 250 31110710
20 40 x 250 31110712
SinoChrom APS 10 10 x 250 31110714
10 20 x 250 31110715
10 30 x 250 31110716
15 40 x 250 31110717
20 40 x 250 31110719
SinoChrom SiO2 10 10 x 250 31110721
10 20 x 250 31110722
10 30 x 250 31110723
15 40 x 250 31110724
20 40 x 250 31110726
SinoChrom 300 Å ODS-AP 10 10 x 150 31110728
10 10 x 200 31110729
10 10 x 250 31110730
10 10 x 300 31110731
10 20 x 150 31110394
10 20 x 200 31110732
10 20 x 250 31110733
10 20 x 300 31110734
10 30 x 150 31110735
10 30 x 200 31110736
10 30 x 250 31110567
10 30 x 300 31110571
15 40 x 250 31110737
SinoChrom 300 Å C8 10 10 x 250 31110739
10 20 x 250 31110740
10 30 x 250 31110741
15 40 x 250 31110742
SinoChrom 300 Å C4 10 10 x 250 31110744
10 20 x 250 31110745
10 20 x 300 31110746
27
15 40 x 300 31110747
Columns used for Rapid analysis
Ordering Guide
Descriptions Particle size (μm) Specification (mm) Part No. List Price (USD )
Hypersil C18 3 2.1 x 50 31110485
3 2.1 x 100 31110486
3 4.0 x 50 31110521
3 4.0 x 100 31110017
3 4.6 x 50 31110438
3 4.6 x 100 31110229
3 4.6 x 150 31110543
Hypersil C8 3 2.1 x 50 31110795
3 2.1 x 100 31110484
3 4.0 x 50 31110796
3 4.0 x 100 31110797
3 4.6 x 50 31110798
3 4.6 x 100 31110398
3 4.6 x 150 31110601
Hypersil C18 3 2.1 x 50 31110490
3 2.1 x 100 31110435
3 4.0 x 50 31110532
3 4.0 x 100 31110337
3 4.6 x 50 31110592
3 4.6 x 100 31110159
3 4.6 x 150 31110052
Hypersil BDS C8 3 2.1 x 50 31110799
3 2.1 x 100 31110800
3 4.0 x 50 31110801
3 4.0 x 100 31110802
3 4.6 x 50 31110803
3 4.6 x 100 31110804
3 4.6 x 150 31110879
JiajieTM Guard Columns
Moss guard columns are designed with replacement dropin cartridges and packed with imported pack-
ings.
28
Showing from many researches: the polluted column head mainly causes the increase of column pres-
sure, so we put a short column in front end to protect the expensive chromatographic column that is en-
hancing chromatography. Normally speaking, the packings in the guard column are similar to guard
column. Guard column are economical, practical means of extending column lifetime and the column.
JMAIC JiajieTM Guard column designs with convenient, ultra new replaceable drop-in cartridges, so you
only need to replace a new drop-in cartridge when the samples are unclean or start another lab.
Ordering Guide
Descriptions Particle size (μm) Package
(pcs) Part No. List Price (USD )
Guard Column Holders 4.6 × 10mm 1 31110102
C18-Drop-in Guard Cartridges 4.6 × 10mm 1 31110130
4.6 × 10mm 4 31110855
NH2-Drop-in Guard Cartridges 4.6 × 10mm 1 31110157
4.6 × 10mm 4 31110856
C8-Drop-in Guard Cartridges 4.6 × 10mm 1 31110128
4.6 × 10mm 4 31110857
C6H5-Drop-in Guard Cartridges 4.6 × 10mm 1 31110101
4.6 × 10mm 4 31110858
CN-Drop-in Guard Cartridges 4.6 × 10mm 1 31110100
4.6 × 10mm 4 31110859
C1-Drop-in Guard Cartridges 4.6 × 10mm 1 31110527
4.6 × 10mm 4 31110860
BDS C18-Drop-in Guard Cartridges 4.6 × 10mm 1 31110129
4.6 × 10mm 4 31110861
C4-Drop-in Guard Cartridges 4.6 × 10mm 1 31110451
4.6 × 10mm 4 31110862
SAX-Drop-in Guard Cartridges 4.6 × 10mm 1 31110340
4.6 × 10mm 4 31110863
300 Å C18-Drop-in Guard Cartridges 4.6 × 10mm 1 31110540
29
4.6 × 10mm 4 31110864
300 Å C8-Drop-in Guard Cartridges 4.6 × 10mm 1 31110358
300 Å C4-Drop-in Guard Cartridges 4.6 × 10mm 1 31110865
Silica-Drop-in Guard Cartridges 4.6 × 10mm 1 31110220
Dextrangel Column Special
Dextrangel packing parameters
Phase Particle
Size(μm) Pore Size(Å) Column Bed (mL/g)
Separation Range
pep-
tides/proteins
polysaccha-
rides
Sephadex
G-10 40-120 60 2-3 <700 <700
Ordering Guide
Descriptions Specification (mm) Part No. List Price (USD )
Sephadex G-10 10 x 300 31110088
15 x 300 31110144
10 x 400 31110334
15 x 400 31110089
10 x 500 31110322
14 x 300 31110092
Columns for Amino Acids Analysis System
30
Ordering Guide
Descriptions Specification (mm) Part No. List Price (USD )
Column for Amino Acids Analysis 4.6 x 250 31110091
Guard column 4.6 x 10
Reagent kit 31990001
Standard substance 18 / 5mg 31990002
HPLC Instruments
Assembly Unit
P1201 HPLC Pump
Flow Range 0.001mL/min-9.999mL/min
increament: 0.001 mL/min
Precision ≤±0.5% (1.000mL/min, 8.5Mpa, wa-
ter, ambient temperature)
Accuracy RSD≤0.1% (1.000mL/min, 8.5Mpa,
water, ambient temperature)
RSD≤0.3% (0.001mL/min-9.999
mL/min )
Max Pres-
sure
40Mpa (0.001mL/min-5.000 mL/min)
20Mpa (5.001mL/min-9.999 mL/min)
Pressure
Precision
≤±3% or 0.5MPa
Pressure
Pulsation
≤1.0%
Rear-piston
cleaner
On-line (optional)
Power AC 110V/220V, 50Hz/60Hz
Consumption 180W
Dimensions 420mm x 300mm x 175mm
■Ordering Details
Item Part No. Price(USD )
P1201 HPLC Pump 31010013
31
P230 HPLC Pump
Flow Range 0.001mL/min-9.999mL/min
increament: 0.001 mL/min
Precision ≤±0.3% (1.000mL/min, 8.5Mpa, water,
ambient temperature)
Accuracy RSD≤0.1% (1.000mL/min, 8.5Mpa,
water, ambient temperature)
Max Pres-
sure
40Mpa (0.001mL/min-5.000 mL/min)
20Mpa (5.001mL/min-9.999 mL/min)
Pressure
Precision
≤±3%
Pressure
Pulsation
≤1.0%
Power AC 110V/220V, 50Hz/60Hz
Consumption 180W
Dimensions 420mm x 280mm x 175mm
■Ordering Details
Item Part No. List Price(USD )
P230 HPLC Pump 31010003
P230II HPLC Pump 31010012
UV1201 UV/Vis Detector
Wavelength Range 190nm-700nm
Wavelength Preci-
sion
±0.1nm
Wavelength Accu-
racy
±1.0nm
Optical Bandwidth 6nm
Rise Time 0.0s-4.9s
Baseline Noise ±1.0x10-5
AU (empty cell, 254nm,
time: 1.0s)
Baseline Drift ≤1x10-4
AU/h (empty cell, 254nm,
time: 60min)
32
Flow Cell Analytical flow cell: optical path
length 9mm; volume 10μL
Light Source Deuterium lamp
Power AC 110V/220V, 50Hz/60Hz
Consumption 110W
Dimensions 420mm x 300mm x 175mm
■Ordering Details
Item Part No. Price
UV1201 UV/Vis Detector 31020010
UV230+ /UV230II UV/Vis Detector
Wavelength Range 190nm-720nm
Wavelength Preci-
sion
±0.1nm
Wavelength Accura-
cy
±0.5nm
Optical Bandwidth 6nm
Rise Time 0.0s-9.9s
Linear Range ≥1.5AU (5%)
Baseline Noise ±1.5x10-5
AU (empty cell, 254nm,
time: 1.0s)
Baseline Drift ≤3x10-4
AU/h (empty cell, 254nm,
time: 60min)
Flow Cell Analytical flow cell: optical path
length 10mm; volume 10μL
Semi-preparative flow cell: optical
path length 3mm; volume 5μL
Light Source Deuterium lamp and Tungsten lamp
Power AC 110V/220V, 50Hz/60Hz
Consumption 110W
Dimensions 420mm x 280mm x 175mm
■Ordering Details
Item Part No. Price
UV230+ UV/Vis Detector 31020004
UV230II UV/Vis Detector 31020009
33
RI230II Refractive Index Detector
Refractive Index Range 1.00-1.75
Detect Range 1/4RIU/FS-5.12 x10-6 RIU/FS
Linear Range 6 x10-4 RIU
Noise ≤2.5x10-9
RIU (STD response)
Auto Zero Range ≥±1x10-4
RIU
Auto Zero Resolution ≥1x10-8
RIU
Drift Adjusting Range 0-6x10-6
RIU
Drift Resolution 3x10-8
RIU
Rise Time FAST, STD, SLOW
Contact Input Purge, Auto zero, Marker, Polar-
ity
Contact Output Intensity alarm, Zero over,
Marker
Temperature Setting 35℃
Cell Volume 8μL
Max Flow Rate 10 mL/min (mobile phase is pure
water)
Max Pressure 0.05MPa
Solvent Contact Parts Stainless steel, Teflon, Quartz
glass
Power AC 110V/220V, 50Hz/60Hz
Consumption 60W
Dimensions 400mm x 260mm x 150mm
■Ordering Details
Item Part No. Price
RI230II Refractive Index Detector 32060089
DAD230+ Diode Array Detector
The DAD230+ Diode Array Detector is the core of powerful and productive systems for routine and occa-
sional users that are easy to use and integrate seamlessly into the modern laboratory. The spectropho-
tometer comes equipped with all the diode-array advantages-fast scanning, excellent sensitivity, virtually
absolute wavelength reproducibility, exceptional ruggedness and reliability, minimum maintenance, and
significant improvements in optical performance.
The DAD230+ Detector has to be used with MAIC’s EC2000 DAD software.
34
Characteristics:
A completely closed optical system and optical fiber based transmission technique for higher spectral
accuracy and stability.
Combined with the powerful data processing system (EC2000 DAD Data System Workstation), the in-
strument provides a full information including chromatogram, spectra of components, three dimension
information and peak purity results.
Wavelength Range 190nm-618nm (512 diodes)
190nm-1015nm (1024 diodes)
Wavelength Preci-
sion
±0.1nm
Wavelength Accu-
racy
±0.5nm
Optical Bandwidth /
Rise Time 0.0s-9.9s
Linear Range ≥1.5AU (5%)
Baseline Noise ±2.0x10-5
AU (empty cell, 254nm, time:
1.0s)
Baseline Drift ≤1x10-3
AU/h (empty cell, 254nm, time:
60min)
Flow Cell Analytical flow cell: optical path length
10mm; volume 10μL
Semi-preparative flow cell: optical path
length 3mm; volume 5μL
Light Source Deuterium lamp and Tungsten lamp
Power AC 110V/220V, 50Hz/60Hz
Consumption 110W
Dimensions 420mm x 280mm x 175mm
■Ordering Details
Item Part No. Price
DAD230+ Diode Array Detector (512
diodes)
31020006
DAD230+ Diode Array Detector (1024
diodes)
31020007
35
LU230/LU230II Low-pressure Gradient Unit
Flow Range 0.01mL/min-10.00mL/min
Gradient Setting
Range
0.1%-100.0%
Gradient Precision ≤0.2%
Gradient Accuracy ≤2.0%
Gradient Curve Linearity, step, concavo and con-
vex curve
Vacuum Degassing Binary-quaternary (selectable)
Power Requirement AC 110V/220V, 50Hz/60Hz
Dimensions 420mm x 280mm x 180mm
■Ordering Details
Item Part No. Price
LU230 Low-pressure Gradient Unit 31060005
LU230II Low-pressure Gradient Unit 31060006
LU1201 Low-pressure Gradient Unit 31060010
DG230 On-line Degasser
The DG230 In-line Degasser operates on the principle of Henry’s Law to remove dissolved gases from
HPLC eluent. Henry’s Law states that the mole fraction of a gas dissolved in a liquid is proportional to the
partial pressure of that gas in the vapor phase above the liquid. If the partial pressure of a gas on the
surface of the liquid is reduced, for examples, by evacuation, then a proportional amount of that gas
comes out of solution. The In-line Degasser uses a gas permeable polymer membrane channel to carry
the eluent through the vacuum chamber. When the eluent enters the vacuum chamber, the vacuum
maintains a large differential in gas concentration across the membrane. This accelerates the rate at
36
which the dissolved gases diffuse through the polymer membrane into the vacuum chamber. The gases
are them carried away by the vacuum pump.
Channels 1-5
Max Flow of Single
Channel
10mL/min
Wetted Materials Teflon AF
Degassing Channel
Limited Pressure
4.8x105Pa
Channel Volumn 480μL
Channel Internal Diam-
eter
1.2mm
Pressure Drop 3.9mmHg/mL/min
Power Requirement DC 15V-24V
Dimension 200mm x 150mm x 60mm
■Ordering Details
Item Part No. Price
DG230 On-line Degas-
ser(Duality)
31050001
DG230 On-line Degas-
ser (Quaternion)
31050002
ZWII Column Oven
Temperature Range Ambient plus 5℃-160℃
Temperature Preci-
sion
0.1℃
Accuracy ≤±0.5℃
Temperature Setting 0.1℃
Display 4 digits both for temperature
setting and indication
Power Consumption 145W
■Ordering Details
Item Part No. Price
ZWII Column Oven 31040002
37
AS1201 Auto-Sampler
Precision RSD<0.5%(Full of Sample Loop, or
part of Sample Loop)
Linearity >0.999
Sample residual <0.01%
Number of sample
plates
Two of 60 position 2-mL vial plates
Syringe 250μL(standard), 100μL,
1mL(optional)
Minimum Inject
Volum
0.1μL (250μL Injection Pump)
Sample loop 100μL(Standard); Maximum:5000μL
Switching time of
injection Valve
<100ms
Positional accuracy
of injection Needle
<0.3mm
Mode of Motion X、 Y、 Z (Three-dimensional coor-
dinate)
Injection needle
wash
Wash for inner wall & outer wall of the
needle
Repetition of Sample
Injection
Unlimited
Communication
Mode
LAN/ RS232
Temperature 10 ~ 40℃
Humidity ≤65%, 10~40℃
Pressure 1.01 x 105 Pa
pH Range 1~14
Power AC220V, 50Hz
Dimension 305mm x 470mm x 250mm
Weight 25kg
■Ordering Details
Item Part No. Price
AS1201 Auto-Sampler 31090001
38
RO230/RO1201 Solvent Manager
Channels 2~5
Maxmum Flow rate for
single channel
10mL/min
Material for Channels Teflon AF
Pressure for Channels 0.48MPa
Volume for Channels 480uL
ID for Channel 1.2mm
Pressure Drop 3.9mmHg/mL/min
Dimensions (RO230) 390mm x 280mm x 85mm
Dimensions (RO1201) 420mm x 300mm x 85mm
■Ordering Details
Item Part No. Price (USD )
RO230 Solvent Manager 31080001
RO1201 Solvent Manager 31080002
P230p Semi-Preparative HPLC Pump
Flow Range 0.10mL/min-40.00mL/min
increament: 0.01 mL/min
Precision ≤±1.0% (10.00mL/min, 8.5Mpa, water,
ambient temperature)
Accuracy RSD≤0.2% (10.00mL/min, 8.5Mpa, wa-
ter, ambient temperature)
Max Pressure 30Mpa (0.01mL/min-20.00 mL/min)
20Mpa (20.01mL/min-40.00 mL/min)
Pressure
Precision
≤±3%
Pressure
Pulsation
≤1.0%
Power AC 110V/220V, 50Hz/60Hz
Consumption 200W
Dimensions 420mm x 280mm x 175mm
■Ordering Details
Item Part No. Price
(USD )
P230p Semi-Preparative HPLC
Pump
31010005
39
P270 Preparative HPLC Pump
Flow Range 1.00mL/min-99.99mL/min
increament: 0.01 mL/min
Precision ≤±1.5% (30.00mL/min, 8.5Mpa, water,
ambient temperature)
Accuracy RSD≤1% (30.00mL/min, 8.5Mpa, water,
ambient temperature)
Max Pressure 30Mpa (1.00mL/min-20.00 mL/min)
20Mpa (20.01mL/min-99.99 mL/min)
Pressure
Precision
≤±3%
Pressure
Pulsation
≤3%
Power AC 110V/220V, 50Hz/60Hz
Consumption 260W
Dimensions 420mm x 280mm x 175mm
■Ordering Details
Item Part No. Price(USD )
P270 Preparative HPLC
Pump
31010006
P1000+/P500+ Preparative HPLC Pump
Flow Range P500+ (1~500mL/min, Step 1mL/min)
P1000+ (1~1000mL/min, Step 1mL/min)
Precision ±3% (5Mpa, water, ambient tempera-
ture)
Accuracy RSD≤0.5%
Max Pressure P500+ (0~500mL/min, 20MPa)
P1000+
(0~500mL/min, 20MPa)
P1000+
(>500mL/min, 10MPa)
Pressure
Precision
±5% (0.5MPa)
Temperature 0~40℃
Humidity ≤80%
Power AC 220V ±10%V, 50/60Hz
Consumption 800W
Dimensions 350mm x 600mm x 230mm
■Ordering Details
Item Part No. Price(USD )
P500+ Preparative 31010023
40
HPLC Pump
P1000+ Preparative
HPLC Pump
31010024
P2000+ Preparative HPLC Pump
Flow Range 1~2000mL/min, Step 1mL/min
Precision ±3% (5Mpa, water, ambient tempera-
ture)
Accuracy RSD≤0.5% (1000mL/min, 5MPa, Wa-
ter,R.T.)
Max Pressure 0~1000mL/min, 10MPa
1001~2000mL/min, 5MPa
Pressure
Precision
±5% (0.5MPa)
Temperature 0~40℃
Humidity ≤80%
Power AC 220V ±10%V, 50/60Hz
Consumption 800W
Dimensions 350mm x 600mm x 230mm
■Ordering Details
Item Part No. Price(USD )
P2000+ Preparative
HPLC Pump
31010025
Can be customed by order
41
HPLC System Configurations
Moss iChrom 5100 HPLC System
Isocratic Systems Configurations
Item Description Quantity
1 iChrom P5100 High Pressure Constant Flow Pump 1 ea
2 iChrom D5100 UV/VIS Detector 1 ea
3 iChrom S5100 Auto-Samper (alternative) 1 ea
4 Rheodyne 7725i Sample Injector 1 ea
5 iChrom O5100 Column Oven (alternative) 1 ea
6 iChrom HPLC Column 1 ea
7 iChom W5100 Workstation 1 set
8 iChrom M5100 System Manager 1 ea
Binary High Pressure Gradient Systems Configurations
Item Description Quantity
1 iChrom P5101 Binary High Pressure Constant Flow Pump 1 ea
42
2 iChrom D5100 UV/VIS Detector 1 ea
3 iChrom S5100 Auto-Samper (alternative) 1 ea
4 Rheodyne 7725i Sample Injector 1 ea
5 iChrom O5100 Column Oven (alternative) 1 ea
6 iChrom HPLC Column 1 ea
7 iChom W5100 Workstation 1 set
8 iChrom M5101 System Manager (include Binary Degasser) 1 ea
Quaternary Low Pressure Gradient Systems Configurations
Item Description Quantity
1 iChrom P5102 Quaternary High Pressure Constant Flow Pump 1 ea
2 iChrom D5100 UV/VIS Detector 1 ea
3 iChrom S5100 Auto-Samper (alternative) 1 ea
4 Rheodyne 7725i Sample Injector 1 ea
5 iChrom O5100 Column Oven (alternative) 1 ea
6 iChrom HPLC Column 1 ea
7 iChom W5100 Workstation 1 set
8 iChrom M5102 System Manager (include Quaternary Degasser) 1 ea
P1201 Isocratic Systems Configurations
P1201 High Pressure Constant
Flow Pump
1 ea
UV1201 UV/VIS Detector 1 ea
Rheodyne 7725i Sample In-
jector
1 ea
SinoChrom ODS-BP Column,
5m I.D.:4.6mm×200mm
1 ea
EC2006 Chromatography
Workstation (Single Channel,
without PC and printer)
1 Unit
■Ordering Details
Item Part No. Price
P1201 Isocratic
Systems
43
P1201 High Pressure Gradient Systems Configurations
P1201 High Pressure Constant
Flow Pump
2 ea
UV1201 UV/VIS Detector 1 ea
Rheodyne 7725i Sample Injector 1 ea
SinoChrom ODS-BP Column, 5m
I.D.:4.6mm×200mm
1 ea
EC2006 Chromatography Work-
station (Single Channel, without PC
and printer)
1 Unit
Gradient Solvent Mixer 1ea
■Ordering Details
Item Part No. Price
P1201 High Pres-
sure Gradient Sys-
tems
P230/P230II Isocratic Systems Configurations
P230/P230II High Pressure Constant
Flow Pump
1 ea
UV230+/UV230II UV/VIS Detector 1 ea
Rheodyne 7725i Sample Injector 1 ea
SinoChrom ODS-BP Column, 5m
I.D.:4.6mm×200mm
1 ea
EC2000/EC2006 Chromatography
Workstation (Single Channel, without
PC and printer)
1 Unit
■Ordering Details
Item Part No. Price
P230 Isocratic Sys-
tems
P230II Isocratic Sys-
tems
44
P230/P230II High-pressure Gradient System Configurations
P230/P230II High Pressure Constant
Flow Pump
2 ea
UV230+/UV230II UV/VIS Detector 1 ea
Rheodyne 7725i Sample Injector 1 ea
SinoChrom ODS-BP Column, 5m
I.D.:4.6mm×200mm
1 ea
EC2000/EC2006 Chromatography
Workstation (Single Channel, Without
PC and Printer)
1 Unit
Gradient Program Interface 1ea
Gradient Solvent Mixer 1ea
■Ordering Details
Item Part No. Price
P230 High-pressure Gra-
dient System
P230II High-pressure
Gradient System
Semi-Preparative Isocratic System Configurations
P230p High Pressure Constant Flow
Pump
1 ea
UV230II UV/VIS Detector (Preparative
Flow Cell)
1 ea
Rheodyne 3725i-038 Sample Injector 1 ea
EC2006 Chromatography Workstation
(Single Channel, Without PC and Print-
er)
1 Unit
■Ordering Details
Item Part No. Price
P230p Isocratic System
Semi-Preparative Isocratic System Configurations
P270 High Pressure Constant Flow
Pump
1 ea
UV230II UV/VIS Detector (Preparative
Flow Cell)
1 ea
Rheodyne 3725i-038 Sample Injector 1 ea
EC2006 Chromatography Workstation
(Single Channel, Without PC and Print-
1 unit
45
er)
■Ordering Details
Item Part No. Price
P270 Isocratic System
Preparative Isocratic System Configurations
P1000+/P500
+ High Pressure Constant
Flow Pump
1 ea
UV230II UV/VIS Detector (Preparative
Flow Cell)
1 ea
Rheodyne 3725i-038 Sample Injector 1 ea
EC2006 Chromatography Workstation
(Single Channel, Without PC and Print-
er)
1 unit
■Ordering Details
Item Part No. Price
P500+ Isocratic System
P1000+ Isocratic System
46
Semi-preparative Gradient System Configurations
P230p High Pressure Constant Flow
Pump
2 ea
UV230II UV/VIS Detector (Preparative
Flow Cell)
1 ea
Rheodyne 3725i-038 Sample Injector 1 ea
EC2006 Chromatography Workstation
(Single Channel, Without PC and Print-
er)
1 unit
Gradient Program Interface for
P230p/P270
1ea
Gradient Solvent Mixer 1ea
■Ordering Details
Item Part No. Price
P230p Gradient System
Semi-preparative Gradient System Configurations
P270 High Pressure Constant Flow
Pump
2 ea
UV230II UV/VIS Detector (Preparative
Flow Cell)
1 ea
Rheodyne 3725i-038 Sample Injector 1 ea
EC2006 Chromatography Workstation
(Single Channel, Without PC and Print-
er)
1 unit
Gradient Program Interface for
P230p/P270
1ea
Gradient Solvent Mixer 1ea
■Ordering Details
Item Part No. Price
P270 Gradient System
47
Preparative Gradient System Configurations
P1000+/P500
+ High Pressure Constant
Flow Pump
2 ea
UV230II UV/VIS Detector (Preparative
Flow Cell)
1 ea
Rheodyne 3725i-038 Sample Injector 1 ea
P1000+/P500
+ System Kits 1ea
EC2006 Chromatography Workstation
(Single Channel, Without PC and Print-
er)
1 unit
■Ordering Details
Item Part No. Price
P500+ Preparative Gra-
dient System
P1000+ Preparative Gra-
dient System
48
LU230/LU230II Quaternary Low-pressure Gradient System
LU230 low-pressure gradient unit is specially designed for upgrading an isocratic pump LC system into
multi-pumps low-pressure system. With the unit you can conduct mixing and degassing among 2-4 kinds
of solvents, before proceeding with gradient LC analysis.
P230/P230II High Pressure Constant
Flow Pump
1 ea
LU 230 low-pressure gradient unit 1 ea
DG 230-4 in-line degasser 1 ea
UV230+ /UV230II UV/VIS Detec-
tor/DAD230+ diode array detector
1 ea
Rheodyne 7725i Sample Injector 1 ea
SinoChrom ODS-BP Column, 5m
I.D.:4.6mm×200mm
1 ea
EC2000/EC2006 Chromatography
Workstation (Single Channel, Without
PC and Printer)
1 unit
■Ordering Details
Item Part No. Price
LU230 Quaternary
Low-pressure Gradient
System
LU230II Quaternary
Low-pressure Gradient
System
Quaternary gradient system step experiment
with 1% increment
Gradient elution condition for analysis of hop
Item time(min) A/% B/% C/% D/% Shape
1 0.00 20.0 35.0 10.0 35.0 1.000
2 2.00 20.0 10.0 10.0 60.0 1.000
3 26.00 10.0 0.0 10.0 80.0 0.000
4 35.00 10.0 0.0 10.0 80.0 1.000
5 37.00 20.0 35.0 10.0 35.0 1.000
49
Tests of hop under low pressure quaternary gra-
dient system
Amino Acids Analysis System
MOSS-AAK Amino Acids Analysis System
MOSS-AAK Amino Acids Analysis System adopts chroma-
tographic workstation to accurately control the binary HPLC
high pressure gradient system, and offers accurate flow
speed and mobile phase control. Using pre-column deriva-
tion with 2,4-Dinitro-Fluorobenzene (DNFB) and special
amino acids analysis chromatography column, 18 kinds of
amino acids can be separated distinguishably. A UV/Vis
Detector is normally used for the detection of the amino
acids.
◇ P230 High-pressure Gradient System Configurations
◇ Accessories of Moss-AAK analyze amino acid
Absolutely Necessarily Products Of Analyze Amino Acid
Constant Temperature Water Bath 1ea
ZWII Column Oven 1ea
Diaphragm Vacuum Pump 1ea
Ultrasonic Bench Top Cleaner 1ea
Amino Acid Special Column 1ea
Amino Acid Guard Column 1ea
Box of Amino Acid Reagent 1ea
Amino Acid Standard (18kinds, 5mg/kind) 1ea
φ13mm Nylon (organic) (100/pk) 1pk
φ13mm Cellulose (aqueous) (100/pk) 1pk
Φ13mm Sample Filter (Include Nylon and Cellulose, 200/pk) 1pk
φ50mm Solvent Filter (Include Nylon and Cellulose, 100/pk) 1pk
50
■Ordering Details
Item Ordering No. Price
Amino Acid Special Column for AAK 31110091
Amino Acid Guard Column
Box of Amino Acid Reagent 31990001
Amino acid standard (18kinds, 5mg/kind) 31990002
Constant Temperature Water Bath 33120011
51
MOSS-AAP Amino Acids Analysis System
Standard Configurations
P1201 Amino Acids Analysis System
P12101 High Pressure Constant
Flow Pump
2 ea
UV1201 UV/VIS Detector 1 ea
DG 230-4 in-line degasser 1 ea
ZWII Column Oven 1 ea
Rheodyne 7725i Sample Injector 1 ea
Amino Acid Special Column for
AAP
1 ea
Guard Column 1ea
Drop-in Guard Cartridge 2ea
ZJ-1 Vave and Bracket 1ea
TD-1-15 Gradient Solvent Mixer 1ea
EC2006 Chromatography Work-
station
1ea
P1201 Gradient System Kits 1ea
■Alternative for Upgrade
Item Quantity
P1201 Solvent Mixer (include
Binary Degasser)
1ea
AS1201 Auto-Sampler 1ea
52
1. Asp; 2. Glu; 3. Ser; 4. Gly; 5. His; 6. Arg; 7. Thr; 8. Ala; 9. Pro; 10. Tyr; 11. Val; 12. Met; 13Cys
14. Ile; 15. Leu; 16. Phe; 17Lys;
53
Chromatography Data-processing Workstation
EC2006 Chromatography Data-processing Workstation
54
EC2000 Chromatography Data-processing Workstation
EC2006/EC2000 Chromatography data-processing workstation is the new generation chromatography
workstation, with a completely fresh external-connect design hardware and software based on Win-
dows98/XP/2000 dual channels application procedures, with up to date software design technology (O-O)
and the experiences collection of many experts and clients, all of the above make it to be a more func-
tional, and easily-operated workstation.
EC2006/EC2000 is easily operated as MS OFFICE software. Such as, analyze complex samples with
visual and graphical button on line; call out chromatogram with clipboard under the software of WORD
and cerate a report of pictures and words; sent chromatogram by means of E-mail with link procedure;
browse information on internet while not leaving EC2006/EC2000.
EC2006/EC2000 can accommodate any types of chromatography instruments (GC, LC, IC, CE), and is
the ideal substitute of integrator, data processor and traditional workstation, so it will be your right hand in
your laboratory analysis.
EC2000 GPC Chromatography Data-processing Workstation
Based on EC2006/EC2000 workstation, EC2000 GPC adds GC data-processing function. Its characters
are as follows:
◇Standards Calibration
Calculate calibration curve according to molecular weight averages and dispersion coefficient of mono-
disperse or broad standards , to Mark-Houwink (k and a) of narrow or unknown samples; eliminate ex-
periment error by calibrating results of parallel injection of arbitrary number and all kinds standards; re-
gress calibration curve with simple equation, quadratic equation or cubic equation, and auto-calculate
standard error and correlation coefficient; obtain standards average molecular weight and error by re-
versed calculating with fitting curve, and can visually judge and modify fitting results.
55
◇Molecular Weight Determination
By means of molecular weight calibration curve and peak slicing area, calculate number-average molec-
ular weight, weight-average molecular weight, Z average molecular weight, Z+1 average molecular
weight, viscosity-average molecular weight and correlation coefficient of high molecular weight substance;
calculate and analyze any range of the chromatogram by setting up slicing.
◇Molecular Weight Distribution
Calculate to obtain integrated molecular weight distribution curve, differential molecular weight distribu-
tion curve; display distribution plots in the following 3 methods: molecular weight, molecular weight loga-
rithm and logarithmic scale reference frame.
◇Output Results and Printing
Output GC separation chromatogram, calibration curve, integration molecular weight distribution curve,
differential molecular weight distribution curve, various molecular weight and correlation parameters
calculation results; select part or full range to calculate, output, print result with tangent incision method in
accordance with experiment purpose; sent molecular weight results table, molecular distribution plot,
molecular distribution data, calibration curve, standards molecular weight data to clipboard and then
process under Word or EXCEL.
EC2000DAD Chromatography Data-processing Workstation
To guarantee DAD system a stable operation under Windows98/XP2000, we adopt virtual driver. With a
friendly interface and strong function DAD data-processing platform, users can conveniently observe and
process contour map, spectrogram, chromatogram and three-dimensional spectrogram-chromatogram.
With sufficient functions of chromatographic data processing and quantitative calculating, arbitrary re-
volving and parts magnifying, users can obtain more vivid visual effect and results analysis.
DAD workstation can provide all kinds of chromatograms, including single wavelength, arbitrary
56
two-wavelength absorbance, wavelength time procedure, max absorption wavelength and total absorp-
tion, and among them, the most sensitive detection method is max absorption wavelength chromatogram,
while the best method to quantitative reproducibility is total absorption chromatogram.
DAD system provides many discrimination methods on peaks purity, including contour map,
three-dimensional spectrogram-chromatogram, overlap spectrogram, wavelength comparison diagram
and peaks purity calculating method.
Users can conveniently built their ultraviolet spectrogram gallery with the multifunctional spectrogram
gallery managing and searching procedure, and the programme can auto-pick spectrogram to each peak
from spectrogram, chromatogram and three dimensional data; auto-search spectrogram gallery; users
can also add the auto-picked spectrogram into appointed gallery.
■Ordering Details
Item Part No. Price
EC2006 Chromatography Workstation(Double Channel)
EC2000 Chromatography Workstation(Single Channel) 31030001
EC2000 Chromatography Workstation(Double Channel) 31030002
EC2000 GPC Chromatography Workstation(Single Channel) 31030012
EC2000 GPC Chromatography Workstation(Double Channel) 31030013
Waters 510 Gradient Program Interface 18060001
Waters 515 Gradient Program Interface 18060003
P230 Gradient Program Interface 18060019
P270 Gradient Program Interface 18060020
57
Dealers
MOSS is the authorized agent of Themo Fisher Scientific, Shodex, Daicel, TOSHOH, and IDEX (which
includes UPCHURCH, Rheodyne, and I.T.)
Thermo Fisher Scientific (Hypersil columns series)
Shodex columns series
Daicel chiral columns series
TSK-GEL columns series
Upchurch accessories series
Rheodyne injection valves series
58
HPLC Accessories
Tubing and Connections
■Ordering Details
Item Description Part No. Price (USD )
SS316L Stainless Steel Tubing
1/16"O.D. x 0.04"I.D. A210005
1/16"O.D. x 0.03"I.D. A210004
1/16"O.D. x 0.02"I.D. A210003
1/16"O.D. x 0.01"I.D A210002
1/16"O.D. x 0.007"I.D A210001
PEEK Tubing
1/16"O.D. x 0.04"I.D. A310005
1/16"O.D. x 0.03"I.D. A310009
1/16"O.D. x 0.02"I.D. A310004
1/16"O.D. x 0.01"I.D. A310007
1/16"O.D. x 0.01"I.D. A310007
Tefzel (ETFE) Tubing
ID: 1.6mm A310025
ID: 2.4mm A310024
QG-2 Tubing cutters kit
Including 2 wrenches C180011
PEEK Tubing
Including 2 pieces of
blades
C180012
SS316 Stainless Steel Con-
nections
1/16" A460002
1/8" A460012
SS316 Stainless Steel Fer-
rules
1/16" A460001
1/8" A460007
PEEK ferrules
1/16" A460003
SS316L Stainless Steel Union
SS316L Stainless S1teel var-
iable diameter Union
1/16" C170019
1/16"-1/8" C170145
1/8" C180045
59
SS316L Stainless Steel Tee
1/16" C170020
SS316L Stainless Steel Cross
1/16" C170021
TD-1-15 Gradient Mixer
TD-1-25 Gradient Mixer
TD-1-30 Gradient Mixer
Micro-analytical scale C170060
Analytical scale C170064
Preperative scale C170061
Universal column connections
Patent products C180021
60
Filters
■Ordering Details
Item Description Part No. Price (USD )
SS316L Stainless Steel Sam-
ple Filter
Frit,Ф 13mm C170015
Ф 13mm Cellulose Membrane
0.45 μm,
200pcs/package
C2E0003
Ф 13mm Nylon Membrane 0.45 μm,
200pcs/package
C2E0004
Ф 13mm Cellulose Membrane 0.22 μm,
200pcs/package
C2E0001
Ф 13mm Nylon Membrane 0.22 μm,
200pcs/package
C2E0002
GM Septum Vacum Pump
C2B0009
Solvent Filter
1000mL C2G0003
Solvent Filter 2000mL C2G0004
Solvent Filter Cup C2G0005
Inlet Solvent Flter C2G0006
Solvent Filter Bottle 1000mL C2G0007
Ф 50mm Cellulose Membrane
0.45 μm,
100pcs/package
C2E0009
Ф 50mm Nylon Membrane 0.45 μm,
100pcs/package
C2E0010
Ф50mm Cellulose Membranee 0.22 μm,
100pcs/package
C2E0011
Ф 50mm Nylon Membrane 0.22 μm,
100pcs/package
C2E0012
Ф 13mm Cellulose Membrane
0.45 μm, 100
pcs/package
C2B0006
Ф 13mm Nylon Membrane 0.45 μm, 100
pcs/package
C2B0002
Ф 25mm Cellulose Membrane 0.22 μm, 100
pcs/package
C2B0003
Ф 25mm Nylon Membrane 0.22 μm, 100
pcs/package
C2B0007
61
Ф 13mm Cellulose Membrane
0.22 μm, 100
pcs/package
C2B0001
Ф 13mm Nylon Membrane 0.22 μm, 100
pcs/package
C2B0005
Ф 25mm Cellulose Membrane 0.45 μm, 100
pcs/package
C2B0004
Ф 25mm Nylon Membrane 0.45 μm, 100
pcs/package
C2B0008
On-line Filter
Filter piece
C170014
C20C-402
Solvent Filter
Analytical scale C170051
Preparative scale C170052
AS3120 Ultrasonic Cleaner
AS5150A Ultrasonic Cleaner
PW: 120W, Volume: 3L C2F0001
Volume: 6L C2F0003
62
Syringes
■Ordering Details
Item Description Part No. Price (USD )
Home-made Syringes
10 μL, for 7125, 7725 syringe C2C0002
25 μL, for 7125, 7725 syringe C2C0003
50 μL, for 7125, 7725 syringe C2C0004
100 μL, for 7125, 7725 sy-
ringe
C2C0005
Hamilton Syringes
10 μL, for 7125, 7725 syringe C2A0001
25 μL, for 7125, 7725 syringe C2A0002
50 μL, for 7125, 7725 syringe C2A0003
100 μL, for 7125, 7725 sy-
ringe
C2A0004
250 μL, for 7125, 7725 sy-
ringe
C2A0005
500 μL, for 7125, 7725 sy-
ringe
C2A0006
SGE Syringes
5 μL, for 7125, 7725 syringe C290005
10 μL, for 7125, 7725 syringe C290001
25 μL, for 7125, 7725 syringe C290002
50 μL, for 7125, 7725 syringe C290006
100 μL, for 7125, 7725 sy-
ringe
C290004
250 μL, for 7125, 7725 sy-
ringe
C290003
500 μL, for 7125, 7725 sy-
ringe
C290007
Home-made Special
Injection Needle
For Rheodyne 25 series in-
jectors
C2Z0011
63
Columns Accessories
■Ordering Details
Item Description Part No. Price (USD )
Hardware Kits
ID: 4.6mm, L: 150mm AB15463020
ID: 4.6mm, L: 200mm AB20463020
ID: 4.6mm, L: 250mm AB25463020
JiajieTM Empty
Guard Column
OD:8mm, L:28mm B150176
Frit Sheet
ID: 4.6mm A450120
Seal Fittings
Blue A450115
Variable connector
for precolumn and
analytical column
C180002
Fixed connector
for precolumn and
analytical column
C180001
64
Instruments Accessories
■Ordering Details
Item Description Part No. Price (USD )
ZJ-1 Holder, for injection in-
jector and column
C170023
ZJ-2 Holder, for Rheodyne 25
series injectors
C170080
ZJ-3 Holder, for Rheodyne
switching injectors
C170031
Solvent Bottle (colourless)
100mL
250mL C2Z0001
500mL C2Z0002
1000mL C2Z0003
2000mL C2Z0004
Solvent Bottle (dark brown) 250mL C2Z0048
500mL C2Z0047
1000mL C2Z0049
FL-1 Splitter
Variable C170031
JC200-1 Flow Cell
JC200-2 Flow Cell
8μL, UV200II, Ana-
lytical
C170041
3μL, UV200II, Ana-
lytical
C170043
Deuterium Lamp
Moss UV200II C2J0004
Moss UV230+ C2J0006
Waters 484 C2K0060
Waters 486 C2K0058
Waters 2487 C2K0059
Agilent HP-1100 C2K0057
Shimadzu SPD-10A C2K0061
Linear 100(LabAlliance
Model 500,TSP-100)
C2K0062
Thermo SP8800 C2K0063
PE LC-200 C2K0064
Hitachi/Merck L3000,4000 C2K0065
65