circle - h, helideck lighting system for a safer...

20
Circle - H, Helideck lighting system ... for a safer landing

Upload: lemien

Post on 27-Jul-2018

233 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

Circle - H, Helideck lighting system... for a safer landing

Page 2: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

All values mentioned in this document are typical values. Document no. CES……………….

HCCPEXHelideck Central Control Panel

Explosion proof helideck lighting control and distribution panel suitable for installationin a zone 1 and 2 gas hazardous area. The panel provides full system operation of thehelideck lighting equipment

Key features Central panel easier for maintenance; in electronics friendly environment for

maximum reliability. The panel can be placed away from extreme conditions in a central location

allowing for easy maintenance and single point of control and monitoring

Standards/Certification EN 60079-0:2006, EN 60079-1: 2007, EN 60079-7:2007 KEMA 02ATEX2103X; ATEX II 2 G Ex de IIB T6…T4, According to ATEX

Directive 94/9/EC IEC 60079-0:2004, IEC 60079-1: 2007, (IEC 60079-7:2007) KEM 09 0089X; Ex d(e) IIB T4

Connections 1 Incoming mains supply 2 Output Circuits for Helideck perimeter lights, L85EX-G-AC 2 Output Circuit for Helideck floodlights, TB-AMG-132-HFL 1 Output Circuit for Illuminated windsock, HWC2000EX-MKII-230 1 Output Circuit for the Helideck status light system, L425EX 1 Output Circuit for the Helideck Circle & H light system, HTP100EX

Electrical characteristics Input voltage: 230Vac Output voltages to below described circuits:

o Perimeter light (230Vac)o Floodlight (230Vac)o Illuminated windsock (230Vac)o Status lights (dedicated voltage)o TD/PM lighting system (dedicated voltage)

Cable entries at the bottom (cable glands excluded) Internal and external earth connection M6

Physical characteristics Dimensions (H x W x D): 730 x 480 x 340 mm Weight: 300 kg Degree of protection: IP66 Control system fitted in seawater resistant cast light alloy epoxy coated

enclosures. All enclosures are fitted on a free standing hot dipped galvanisedsteel frame (floor mounted) (wall mounted)

Finish colour enclosures: RAL 7035

Continued on next page…

Page 3: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

All values mentioned in this document are typical values. Document no. CES……………….

Helideck lighting Control System Control switches and indicator lamps on front of the panel door for status

indications and control capabilities: Helideck perimeter light ON/OFF/AUTO control including status indication. Helideck flood light ON/OFF control including status indication. Helideck windsock ON/OFF/AUTO control including status indication. Helideck status light control including:

o ON/OFF/AUTO/DIMMED control including status indication.o Automatic dimming reset timer (set to 30 minutes)o Remote on/off control by Normally Closed contact or 24Vdc signal

including status indicationo Remote dimming control by (optional) Remote control panel, including

status indication Helideck Circle H lighting ON/AUTO control including status indication. Communication module, for DCS inputs and outputs:

o Common alarm contact for L425 system

The panel will be completely wired in accordance with Orga standards.

Page 4: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

All values mentioned in this document are typical values. Document no. CES……………….

(OPTIONAL)HCCPSAHelideck Central Control Panel

Safe Area helideck lighting control and distribution panel suitable for installation in anon-hazardous area. The panel provides full system operation of the helideck lightingequipment

Key features Central panel easier for maintenance; in electronics friendly environment for

maximum reliability. The panel can be placed away from extreme conditions in a central location

allowing for easy maintenance and single point of control and monitoring Suitable for non-hazardous areas.

Connections 1 Incoming mains supply 2 Output Circuits for Helideck perimeter lights, L85EX-G-AC 2 Output Circuit for Helideck floodlights, TB-AMG-132-HFL 1 Output Circuit for Illuminated windsock, HWC2000EX-MKII-230 1 Output Circuit for the Helideck status light system, L425EX 1 Output Circuit for the Helideck Circle & H light system, HTP100EX

Electrical characteristics Input voltage: 230Vac Output voltages to below described circuits:

o Perimeter light (230Vac)o Floodlight (230Vac)o Illuminated windsock (230Vac)o Status lights (dedicated voltage)o TD/PM lighting system (dedicated voltage)

Cable entries at the bottom (cable glands excluded) Internal and external earth connection M6

Physical characteristics Dimensions (H x W x D): 760 x 600 x 350 mm Weight: 50 kg Degree of protection: IP66 Sheet steel enclosure with high quality dip coat primed powder coating (floor

mounted) (floor mounted) (wall mounted) Finish colour enclosures: RAL 7035

Helideck lighting Control System Control switches and indicator lamps on front of the panel door for status

indications and control capabilities: Helideck perimeter light ON/OFF/AUTO control including status indication. Helideck flood light ON/OFF control including status indication. Helideck windsock ON/OFF/AUTO control including status indication. Helideck status light control including:

o ON/OFF/AUTO/DIMMED control including status indication.o Automatic dimming reset timer (set to 30 minutes)o Remote on/off control by Normally Closed contact or 24Vdc signal

including status indicationo Remote dimming control by (optional) Remote control panel, including

status indication Helideck Circle H lighting ON/AUTO control including status indication. Communication module, for DCS inputs and outputs:

o Common alarm contact for L425 system

The panel will be completely wired in accordance with Orga standards.

Page 5: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

All values mentioned in this document are typical values. Document no. CES……………….

UPSHelideck UPS panel

Power supply panel including battery charger / rectifier and inverter for back-up powersupply of the helideck lighting system

Key features Centralised control panel, allowing for single point of control and monitoring Central panel easier for maintenance; in electronics friendly environment for

maximum reliability. Suitable for Zone 1 gas hazardous areas. Separate Battery charger / Rectifier and Inverter system Completely electronic (solid state) control systems.

Standards/Certification EN 60079-0:2006, EN 60079-1: 2007, EN 60079-7:2007 KEMA 02ATEX2103X; ATEX II 2 G Ex de IIB T6…T4, According to ATEX

Directive 94/9/EC IEC 60079-0:2004, IEC 60079-1: 2007, (IEC 60079-7:2007) KEM 09 0089X; Ex d(e) IIB T4

Connections 1 Incoming mains supply 1 Battery set 1 Output Circuit for Helideck lighting system

Electrical characteristics Main operating voltage: 230Vac Output voltage: 230Vac; 50-60Hz Output voltage to battery 24Vdc

Physical characteristics Dimensions (H x W x D): 730 x 730 x 340 mm Weight: 200 kg Degree of protection: IP66 Control system fitted in seawater resistant cast light alloy epoxy coated

enclosures. All enclosures are fitted on a free standing hot dipped galvanisedsteel frame (floor mounted) (wall mounted)

Finish colour enclosures: RAL 7035

System Design, Control and Monitoring Power ON indicator (Green) Battery charger Mass Sine 24 to 230Vac inverter Output isolation switch, including indicator lamp

Battery charger Series Mass 24/50 Input voltage: 230 V (+/-10%) Input frequency: 50 Hz / 60 Hz (+/-6%) Output voltage Nominal: 24 V Output current: 50 A maximum continuous System indication Led’s for: “Float”, “Absorption” and “On bulk Charge” Failure indicator LED’s for: “Failure” Rectifier failure alarm contact (NO/C)

Page 6: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

All values mentioned in this document are typical values. Document no. CES……………….

Inverter unit Series MASS SINE Inverter Type:

o 24/1500 (Rating 1200VA cont. / 2900VA Peak) Input voltage: 24Vdc (Window 19-30Vdc ±0.5V) Maximum efficiency: 92% Output voltage: 230Vac (±5%) Frequency: 50Hz (±0.01Hz)

The panel will be completely wired in accordance with Orga standards.

Page 7: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

All values mentioned in this document are typical values. Document no. CES……………….

DBO-421Explosion proof battery circuit breaker box

Explosion proof battery circuit breaker box for disconnecting batteries for maintenanceand protection. The assembly is H2 certified.

Key features Explosion proof battery box, suitable

for Zone 1 gas hazardous areas. Certified for areas where Hydrogen

might be present Sea water resistant copper free cast

alloy enclosure, provided with a highquality coating (RAL7035) suitablefor wall mounting

The panel will be completely wired inaccordance to the Orga standards.

Standards/Certification Cenelec EN 60079-0, EN 600079-1 KEMA 02ATEX2103 X;

ATEX II 2 G Ex d IIB+H2 T6…T4,according to ATEX Directive 94/9/EC

IEC 60079-0:2004, IEC 60079-1:2007

KEM 09 0089X; Ex d IIB+H2 T4

Electrical characteristics One circuit breaker, 2 pole

(controllable through enclosurefront, padlockable)

Trip contact for remote indication Terminals Cable entries, size to be specified

Physical characteristics Dimensions approx. 360 x 360 x 270

mm Weight: 40 kg Degree of protection: IP66

Options Rain / Sun Canopy Ex-e terminal boxes (connected to

the Ex-d part by bushings) Rain / Sun Canopy

Page 8: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

All values mentioned in this document are typical values. Document no. CES………………

BB95.55.45.CSZone 1 and 2 Hot dip galvanised steel Battery enclosure

Explosion proof battery enclosure, hot dip galvanised steel provided with Sonnenschein/ Exide VRLA solar battery set Saft Ultima SLM batteries, suitable for offshoreenvironmental conditions

Key features Suitable for Zone 1 and Zone 2 areas with gas explosion hazard Certified for use with Lead acid and Nickel Cadmium batteries Hot dipped galvanised steel enclosure (Stainless steel 316 optional) Top opening cover with padlock Side, bottom and top cover ventilation Battery support at bottom, adjustable wooden framework on top Non-static PVC internal lining Including LEX15B temperature sensor

Standards/Certification Cenelec EN 50014 and EN 50019 KEMA 02ATEX2080 X; ATEX II 2 G EEx e II T6 according to ATEX Directive 94/9/EC

Performance characteristics Provided with GNB / Sonnenschein A600 high capacity tubular plate batteries:

successful dryfit technology. Long life, powerful and versatile for UPS and (alarm)signalling) applications

Electrical characteristics Operating voltage: 24VDC Fitted with 2 cells A612/150 Blocks (12V 3OPzV 150), each rated 137 Ah;

Physical characteristics Dimensions (LxWxH): 690 x 1190 x 503 mm (Overall) Weight: Approx. 100 kg (Including batteries) Degree of protection: IP54

Page 9: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

All values mentioned in this document are typical values. Document no. PIS……………….

L85EX-G-ACExplosion proof LED helideck perimeter light

A new generation of explosion proof LED helideck perimeter lights to meet thedemanding requirements of offshore environmental conditions. The design is based onlow power long life LED technology and use of stainless steel. These fittings meet theregulatory requirements for ICAO, CAP437 and IMO.

Key features Reliable helideck perimeter light Low cost of ownership Low power consumption Serviceable unit, parts are

interchangeable Certified for Zone 1 areas with

increased gas explosion hazard Compact design, meeting the

maximum 250 mm heightrestrictions of IMO

Intensity main beam 30cd green(CAP437)

Impact resistant dome and stainlesssteel 316 body

Spacious, easy to open cableconnection compartment

Photometric test of independentinstitution

Standards/Certification Certified to CAA-UK CAP 437;

Offshore helicopter landing areas -Guidance on standards, 7th edition,chapter 4, paragraph 3.1

Certified to IMO standard MODUcode; 2009 (Edition 2010), chapter13.5.21

Certified to ICAO Annex 14, Volumell; International standards andrecommended practices:Aerodromes, 3rd edition, July 2009,chapter 5.3.8

Cenelec EN 60079-0, EN 60079-7and EN 60079-18

SIRA 12ATEX3066; ATEX II 2GEx e mb IIC T4 Gb according to ATEXDirective 94/9/EC

IEC 60079-0, IEC 60079-7 and IEC60079-18

IECEx SIR 12.0026; Ex e mb IIC T4Gb

Performance characteristics Steady burning; green Intensity: 30cd (60cd maximum) Horizontal beam coverage: 360° Vertical beam profile: as per

CAP437 table Colour chromaticity within the

boundaries as specified by ICAO Light source: LED (100,000 hours

average life)

Electrical characteristics Operating voltage: 100-254Vac; 50-

60Hz Power consumption: 4.5W (6VA) Connection details: M4; two M25x1.5

cable entries Earth connection: internal M4 and

external M6

Physical characteristics Dimensions (L x W x H):

161 x 161 x 111mm Weight: 3.6kg Design degree of protection: IP66 Operating temperature range:

-50°C to +45°C

Page 10: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

All values mentioned in this document are typical values. Document no. PIS……………….

L85EX-G-ACExplosion proof LED helideck perimeter light

Page 11: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

All values mentioned in this document are typical values. Document no. CES No. TB-AMG-HFL-230

TB-AMG-132-HFL (AC)Explosion proof helideck floodlight

Explosion proof ATEX and IECEx certified helideck floodlight to illuminate the landingarea of the helideck, manufactured with a long life Xenon bulb and designed to meetICAO regulatory requirements.

Key features Make: TechNed Benelux BV Reliable helideck flood light, low cost

of ownership Helideck Floodlighting to be

positioned around the landing areato provide good visual cues for thehelicopter pilot

Efficient Xenon light source Certified for ATEX and IECEx Zone 1

areas with gas explosion hazard Compact design, meeting the max.

250mm height restrictions of CAP437and ICAO

Impact resistant window andstainless steel 316 body

Spacious and easy to openintegrated GRP Ex e junction box

Standards/Certification Complies with ICAO Annex 14,

International standards andrecommended practices:Aerodromes, Volume ll - Heliports;4th edition, July 2013, chapter 5.3.9

EN 60079-0: 2009, EN60079-1:2007, EN60079-7: 2007 andEN60079-31: 2009

INERIS 13ATEX0047X; II 2 GD Exd e IIC T4 Gb according to ATEXDirective 94/9/EC

IEC 60079-0: 2011, IEC 60079-1:2007, IEC 60079-7: 2006 and IEC60079-31: 2008

IECEx INE 13.0061X; Ex d e IIC T4Gb

Performance characteristics Lamp type: Xenon 35W, white,

included Optical system: accurate reflector

and lens combination No glare

Electrical characteristics Operating voltage: 110-230Vac 50-

60Hz Power consumption: 50W Connection details: max. 4mm²; two

M25x1.5 cable gland entries Earth connection: internal max.

4mm² Spacious cable connection

compartment, suitable for looping

Physical characteristics Dimensions (L x W x H): 449 x 135 x

133mm Weight: 10kg Degree of protection: IP66 Operating temperature range:

-50°C to +50°C 2x mounting feet

Page 12: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

All values mentioned in this document are typical values. Document no. CES……………….

L425EXExplosion proof LED helideck status (wave-off) light.

Explosion proof ATEX certified LED helideck status (wave-off) light meeting CAP437requirements. Long life LEDs and light weight design, which incorporates stainless steelmounting facilities and low profile design (<250mm), makes product ideal for easyinstallation and long maintenance intervals.

Key features High intensity warning beacon Suitable for Zone 1 and Zone 2 areas

with gas explosion hazard Intensity min. 700cd between a

vertical angle from 2° to 10°, min.176cd outside this angle

Low profile design (<250mm) allowsdirect mounting on helideck

Offshore resistant, high qualitycoating on cast light alloy base

Stainless steel mounting facilities toprevent corrosion problems, andintegrated junction box

State of the art high power LEDs andtechnology provide superior life andreliability

Photometric test report ofindependent institution

Low power consumption due toefficient optical design

Standards/Certification Certified to CAA-UK CAP 437 in

conjunction with separate controlpanel; Offshore helicopter landingareas -Guidance on standards, Aug.2010, chapter 4, paragraph 3.10 –Helideck status light

Complies with ICAO Annex 14,Volume I, Appendix I, July 2004,Figure A1-1 – Colours foraeronautical ground lights

Cenelec EN 60079-0, EN 60079-7and EN 60079-11

KEMA 10ATEX0128; ¤ II 2G Ex e [ib]IIC T5 Gb, according to ATEXDirective 94/9/EC

IEC 60079-0, IEC 60079-7 and IEC60079-11

IECEx KEM 10.0052; Ex e [ib] IIC T5Gb

Performance characteristics Flashing; red Flash frequency 2Hz for a single

main light system; or alternating1Hz per light for a double main lightsystem

Effective intensity: 700cd minimum;60cd maximum in dim mode

Horizontal beam coverage: 360° Vertical beam profile: in compliance

with above mentioned CAArequirements

Colour chromaticity within theboundaries as specified by ICAO

Electrical characteristics Operating voltage: DC voltage from

status light control panel Power consumption: 30W average

when active Connection details: max. 4mm²; one

entry for M25 gland • Earth connection: internal max.

4mm² and external M4

Physical characteristics Dimensions (L x W x H): 451 x 420 x

219mm Weight: 13.5kg Degree of protection: IP66 Operating temperature range: -40ºC

to +55 ºC

System design, control andmonitoring Control, operation and fault

monitoring via separate systemcontrol

Remote control annunciation panel(optional)

Page 13: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

All values mentioned in this document are typical values. Document no. CES……………….

HTP100 CABLETouchdown/positioning light system cable

Custom designed low profile cable, covers and mountings for the Orgahelideck touchdown/positioning light system to meet the requirements ofCAP437. It is suitable for direct mounting on the helideck which makes theproduct ideal for the environmental conditions as well as easy installation.

Key features Integrated cable connection designed to work specifically with the Orga system Suitable for Zone 1 and 2 areas with gas explosion hazard Low profile design allows direct mounting on helideck Offshore resistant, fully sealed, high quality marine cable Flexible construction to allow for deck distortions and improved impact resistance Stainless steel mounting brackets

Standards/Certification Certified to UL AWM Style 20671 90°C 30V bullet

Performance characteristics 2x Conductor: stranded, tinned copper 1.5 mm² (392 x 0.07 mm); Insulation:

special TPE;Colours: red, black 1x Conductor: stranded, tinned copper 0.75 mm² (196 x 0.07 mm); Insulation:

special TPE;Colours: yellow Twisting: 3 cores + swelling and water blocking filling-yarns Taping: swelling and water blocking fleece Jacket: special PUR; Colour:black, semi-gloss; Outer-Ø: 7.0 mm ± 0.2 mm

Electrical characteristic @ 20°C Conductor resistance (1.50 mm²): < 14 Ð/km Conductor resistance (0.75 mm²): < 28 Ð/km Insulation resistance: > 20 MÐ x km Test voltage (core/core): 1.5 kV Operating voltage: > 30 V Connection details: custom design for Orga system

Physical characteristics Storage temperature range: -50°C to +90°C (TBC) Operating temperature range: -20°C to +80°C (TBC) Bending radius: > 40 mm

Page 14: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

All values mentioned in this document are typical values. Document no. CES……………….

SS24EXExplosion proof external photocell

Used in conjunction with the Navaid Central Control Panel (NCCP). The explosion proofphotocell provides automatic control of the marine lanterns / aeronautical obstructionlights at dawn and dusk

Key features Reliable Marine external photocell Low cost of ownership Certified for Zone 1 and Zone 2

areas with gas explosion hazard Compact design Non metallic body Spacious cable connection

Compartment

Standards/Certification Cenelec EN 60079-0, EN 60079-7

and EN 60079-18 KEMA 02ATEX2267 X; ATEX ll 2G

Ex em llC T6 Gb, according to ATEXDirective 94/9/EC

IEC 60079-0, IEC 60079-7 and IEC60079-18

IECEx DEK 11.0024X; Ex e mb IICT6 Gb

Performance characteristics Designed to work in conjunction with

Navaids Central Control Panel(NCCP) concept

Electrical characteristics Operating voltage: Supply from

Navaid Central Control Panel (NCCP) Connection details: max. 2.5mm²;

one M20x1.5 metal cable gland

Physical characteristics Dimensions (L x W x H): 140 x 80 x

57mm Weight: 0.5kg Degree of protection: IP66 Operating temperature range: -50°C

to +55°C

Page 15: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

HWC100EXExplosion proof LED illuminated windsock

All values mentioned in this document are typical values

Document can be subject to modifications, without prior notice. Datasheet no.: HWC100EX

Designed with an internal LED floodlight to illuminate the windsock and prevent glare. Theexplosion proof illuminated windsock provides wind-speed and direction indication topilots during landing and take-off.

Key features• Reliable wind direction and

wind-speed indication forhelicopter operations

• Low cost of ownership• Low power consumption• No dazzling of pilot because of

internal sock illumination• No corrosion due to stainless

steel 316 body• Easy to install• Various operating voltages• Fully integrated aeronautical

obstruction light if required

Standards/Certification• Complies with CAA-UK CAP 437;

Standards for OffshoreHelicopter Landing Areas,chapter 4, paragraph 1.5 –Illuminated windsock

• Complies with ICAO Annex 14,Volume ll; Internationalstandards and recommendedpractices: Aerodromes, chapter5.1.1 – Wind directionindicators for elevatedHeliports & Helidecks

• Complies with ICAO Annex 14,volume l; Aerodrome design andoperations, 6th Edition, 2013,chapter 6.3.2 - Type A and B lowintensity obstruction light

• Complies with CAA-UK CAP 437;Standards for OffshoreHelicopter Landing Areas,chapter 4, paragraph 4.3 – Lowintensity 10cd obstruction light

• Complies to CAA-UK CAP 168,Licensing of Aerodromes Feb2014, chapter 4, table 6A.1Group A. Low intensity 10cdobstruction light

• SIRA 15ATEX1257; ATEX II 2 G Exdb e IIB T5 Gb, according toATEX Directive 94/9/EC EN60079-0, EN 60079-1, EN 60079-7

• IECEx SIR 15.0093; II 2 G Ex dbe IIB T5 Gb IEC 60079-0, IEC60079-1, IEC 60079-7

Performance characteristics• Sock type 1: Red/White/Red;

1200mm ; standard execution• Sock type 2:

Orange/White/Orange; 1200mm ;optional

• Sock type 3: Orange; 1200mm ;optional

• Sock type 4: Red/White/Red;1800mm; optional

• Sock type 5:Orange/White/Orange; 1800mm;optional

Electrical characteristics• Operating voltage: see table• Power consumption: see table• Connection details: max. 4mm²;

two M25x1.5 cable gland entries• Earth connection: internal max.

4mm² and external M8

Physical characteristics• Dimensions (L x W x H): 609 x

460 x 677mm• Weight: 20kg• Design degree of protection:

IP66• Operating temperature range:

-20°C to +60°C

DFT Middle EastTel: +9714 8878185 [email protected] www.dftme.com

Page 16: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

HWC100EXExplosion proof LED illuminated windsock

All values mentioned in this document are typical values

Document can be subject to modifications, without prior notice. Datasheet no.: HWC100EX page 2 of 2

DFT Middle EastTel: +9714 8878185 [email protected] www.dftme.com

Page 17: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

HTP100EX-AExplosion proof LED helideck touchdown/positioning light panel

Orga BVStrickledeweg 133125 AT SCHIEDAMThe Netherlands

P.O. Box 30463101 EA SCHIEDAMThe Netherlands

T +31 (0)10 208 5555F +31 (0)10 437 [email protected]

All values mentioned in this document are typical values

Document can be subject to modifications, without prior notice. Datasheet no.: HTP100EX-A rev 4

CAP437 explosion proof LED helideck touchdown/positioning light panel used inconjunction with a control panel and the helideck identification marking (H). Long life LEDsand light weight design, which is suitable for direct mounting on the helideck due to the lowprofile (<25mm), makes the product ideal for the environmental conditions as well as easyinstallation.

Key features• Panel used for helideck

touchdown/positioning system;‘circle’

• Suitable for Zone 1 and 2 areaswith gas explosion hazard

• Low profile design (<25mm)allows direct mounting onhelideck

• Offshore resistant, fullysealed, high quality marineplastic materials

• Semi-flex construction to allowfor deck distortions andimproved impact resistance

• Stainless steel mountingbrackets to prevent corrosionproblems, and integrated cableconnection

• State of the art high power LEDsand technology provide superiorlife and reliability

• Fully offshore trialled to meetthe operational andenvironmental requirements

Standards/Certification• Complies with CAA-UK CAP 437;

Offshore helicopter landingareas - Guidance on standards,February 2013, chapter 4 andappendix C

• Complies with ICAO Annex 14,Volume I, Appendix I, July 2004,Figure A1-1 – Colours foraeronautical ground lights

• ABS Certificate of DesignAssessment - Orga CAP437 TD/PMCircle-H System -15-LD1264711-PDA

• DEKRA 11ATEX0186; ATEX II 2 G Exe mb [ib] IIC T6 Gb, accordingto ATEX Directive 94/9/EC

• EN 60079-0, EN 60079-7, EN60079-11 and EN 60079-18

• IECEx DEK 11.0072; Ex e mb [ib]IIC T6 Gb

• IEC 60079-0, IEC 60079-7, IEC60079-11 and IEC 60079-18

Performance characteristics• Steady burning; yellow• Effective intensity: 0-10° max.

60cd; 10-20° max. 45cd and20-90° max. 15cd

• Horizontal beam coverage: 2x160°• Vertical beam profile: in

compliance with above mentionedCAA requirements

• Colour chromaticity within theboundaries as specified by ICAO

Electrical characteristics• Operating voltage: Low (10-15V)

DC input from Orga control panel• Power consumption: 1.5W average• Connection details: Orga custom

offshore

Physical characteristics• Dimensions (L x W x H):

503 x 290 x 24mm• Weight: 0.8kg• Design degree of protection:

IP66• Operating temperature range:

-25°C to +55°C

System design, control andmonitoring • Fault monitoring with fail

indication via separate systemcontrol and monitoring box (seeseparate data sheet)

• Custom designed cables withvulcanized cable terminationprotection and captiveconnection screws; multiplelengths to allow for allconfigurations

Page 18: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

HTP100EX-AExplosion proof LED helideck touchdown/positioning light panel

Orga BVStrickledeweg 133125 AT SCHIEDAMThe Netherlands

P.O. Box 30463101 EA SCHIEDAMThe Netherlands

T +31 (0)10 208 5555F +31 (0)10 437 [email protected]

All values mentioned in this document are typical values

Document can be subject to modifications, without prior notice. Datasheet no.: HTP100EX-A rev 4 page 2 of 2

Page 19: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

HTP100EX-GExplosion proof LED heliport identification marking light panel

Orga BVStrickledeweg 133125 AT SCHIEDAMThe Netherlands

P.O. Box 30463101 EA SCHIEDAMThe Netherlands

T +31 (0)10 208 5555F +31 (0)10 437 [email protected]

All values mentioned in this document are typical values

Document can be subject to modifications, without prior notice. Datasheet no.: HTP100EX-G rev 4

CAP 437 explosion proof LED heliport identification marking light panel used inconjunction with a control panel and the helideck touchdown/positioning (circle). Long lifeLEDs and light weight design, which is suitable for direct mounting on the helideck due tothe low profile (<25mm), makes the product ideal for the environmental conditions as wellas easy installation.

Key features• Panel used for heliport

identification marking system;‘H’

• Suitable for Zone 1 and 2 areaswith gas explosion hazard

• Low profile design (<25mm)allows direct mounting onhelideck

• Offshore resistant, fullysealed, high quality marineplastic materials

• Semi-flex construction to allowfor deck distortions andimproved impact resistance

• Stainless steel mountingbrackets to prevent corrosionproblems, and integrated cableconnection

• State of the art high power LEDsand technology provide superiorlife and reliability

• Fully offshore trialled to meetthe operational andenvironmental requirements

Standards/Certification• Complies with CAA-UK CAP 437;

Offshore helicopter landingareas - Guidance on standards,February 2013, chapter 4 andappendix C

• Complies with ICAO Annex 14,Volume I, Appendix I, July 2004,Figure A1-1 – Colours foraeronautical ground lights

• ABS Certificate of DesignAssessment - Orga CAP437 TD/PMCircle-H System -15-LD1264711-PDA

• DEKRA 11ATEX0186; ATEX II 2 G Exe mb [ib] IIC T6 Gb, accordingto ATEX Directive 94/9/EC

• EN 60079-0, EN 60079-7, EN60079-11 and EN 60079-18

• IECEx DEK 11.0072; Ex e mb [ib]IIC T6 Gb

• IEC 60079-0, IEC 60079-7, IEC60079-11 and IEC 60079-18

Performance characteristics• Steady burning; Green• Effective intensity: 2-12° max.

60cd; 12-20° max. 30cd and20-90° max. 10cd

• Horizontal beam coverage: 360°• Vertical beam profile: in

compliance with above mentionedCAA requirements

• Colour chromaticity within theboundaries as specified by ICAO

Electrical characteristics• Operating voltage: Low (10-17V)

DC input from Orga control panel• Power consumption: 0.2W average• Connection details: Orga custom

offshore

Physical characteristics• Dimensions (L x W x H):

503 x 290 x 24mm• Weight: 0.8kg• Design degree of protection:

IP66• Operating temperature range:

-25°C to +55°C

System design, control andmonitoring • Fault monitoring with fail

indication via separate systemcontrol and monitoring box (seeseparate data sheet)

• Custom designed cables withvulcanized cable terminationprotection and captiveconnection screws; multiplelengths to allow for allconfigurations

Page 20: Circle - H, Helideck lighting system for a safer landingcdn.dftme.com/wp-content/uploads/2016/02/Orga-DFT-Circle-H... · / Exide VRLA solar battery set Saft Ultima SLM batteries,

HTP100EX-GExplosion proof LED heliport identification marking light panel

Orga BVStrickledeweg 133125 AT SCHIEDAMThe Netherlands

P.O. Box 30463101 EA SCHIEDAMThe Netherlands

T +31 (0)10 208 5555F +31 (0)10 437 [email protected]

All values mentioned in this document are typical values

Document can be subject to modifications, without prior notice. Datasheet no.: HTP100EX-G rev 4 page 2 of 2