4
Circuit Sensor ® Flow Meter A-506C • Accurate Flow Measurement • Low Pressure Drop • Rugged Wafer-Type Orifice Insert • Compatible with 125, 150, 250, or 300 PSIG ANSI Flanges • Available in sizes from 2-1/2“ to 12”

Upload: others

Post on 19-Apr-2022

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Circuit Sensor Flow Meter - Versa

Circuit Sensor®

Flow Meter

A-506C

• Accurate Flow Measurement

• Low Pressure Drop

• Rugged Wafer-Type Orifice Insert

• Compatible with 125, 150, 250, or 300 PSIG ANSI Flanges

• Available in sizes from 2-1/2“ to 12”

Page 2: Circuit Sensor Flow Meter - Versa

Flow Meter-Type ADescriptionThe Bell & Gossett Circuit Sensor Flow Meter is aprecision machined wafer-type orifice insert. Thisrugged flow meter is designed to monitor system flows at a minimal pressure drop through the flow meter. The Circuit Sensor accommodates a wide range of standard ANSI Flanges, such as the 125, 150, 250 or 300 PSIG.

Determining system flow becomes uncomplicated when using the Circuit Sensor. The system flow rate is obtained by by taking a D P reading across the readout ports, then referring to the calibrated nameplate for the corresponding flow. The Circuit Sensor is available in sizes from 2-1/2” to 12”.

Operating Limitations

1. The Circuit Sensor has a maximum working pressure of 300 PSIG and a maximum operating temperature of 250°F.

2. A minimum length of unrestricted piping must be maintained upstream and downstream of the Circuit Sensor Flow Meter to assure calibrated accuracy. Refer to Data Sheet HS-CSFM-982 or Instruction Sheet G95620C for the

minimum required lengths of unrestricted pipe.

3. The Circuit Sensor Flow Meter is equipped with RV-125A brass readout valves.

CAUTIONWhen monitoring system flow care must be exercised to avoid direct skin or eye contact with liquids that may escape. Liquids with temperatures in excess of 120ºF may cause burns.

D

Page 3: Circuit Sensor Flow Meter - Versa

Typical SpecificationFurnish and install as shown on plans, a cast iron wafer-type flow meter designed for low pressure drop operation.

The flow meter will be equipped with brass readout valves for taking differential pressure readings across the orifice of the flow meter.

The flow meter shall be designed to operate at a maximum working pressure of 300 PSIG at 250°F.

The flow meter must be furnished with a calibrated nameplate for determining an accurate system flow rate.

Each flow meter shall be Bell & Gossett Circuit Sensor Flow Meter Model No. OP-____________.

Page 4: Circuit Sensor Flow Meter - Versa

Xylem Inc. 8200 N. Austin Avenue Morton Grove, Illinois 60053 Phone: (847) 966-3700 Fax: (847) 965-8379www.xyleminc.com/brands/bellgossettBell & Gossett is a trademark of Xylem Inc. or one of its subsidiaries.© 2012 Xylem Inc. A-506C April 2012

Flow vs. Friction Head Loss

Flow vs. Differential Pressure