CISCO NX-OS DATA CENTER FEATURESJack Ross

CCIE #16728

Page 2: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

2

Agenda• Brief Hardware Overview• Software Versions• NX-OS Layer 2• NX-OS Layer 3• FabricPath• Virtual Device Contexts (VDC’s)• Fiber Channel Over Ethernet (FCoE)• Overlay Transport Virtualization (OTV)• Virtual Port Channels (vPC’s)

Page 3: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

3

Nexus 7000 Overview

Nexus 7000/7700

– Typically DC core or aggregation

– High performance, density, & availability

– Unified I/O

FCoE switch but not a FC switch

– Redundant Power, Line Cards and Supervisors

Page 4: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

4

Nexus 7000 Platform Overview

• Currently 7 form factors

– 7018, 7010, 7009, 7004, 7718, 7710,7706

• Currently 2 types of line cards

– M Series Cards - Layer 3 cards

• Feature rich cards

– F Series Cards - Layer 2 cards*

• Performance oriented cards

Page 5: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

5

Line Card Features

• M Series Specific

– Layer 3 Routing

– FEX

– OTV

– TrustSec

• F Series Specific

– FabricPath

– vPC+

– FCoE

Page 6: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

6

Nexus 5000 Overview

Nexus 5000/5500

– Typically End of Row (EoR) aggregation or Top of Rack (ToR) access

– Typically Layer 2 but can do limited Layer 3 with add on daughter card in the 5500 Series

Unified I/O

– Both FCoE and native FC switching

– Redundant power but not supervisors

Page 7: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

7

Nexus 5000 Platform Overview• Currently 2 Generations

– 1st Gen - Nexus 5000 – 5010 & 5020

– 2nd Gen - Nexus 5500 – 5548 & 5596

• Mainly layer 2 switching

– 5500 can support L3 add-in card

• Supports Unified I/O

– Both FCoE Forwarder (FCF) and native FC switching

• 5500 supports Unified Ports (UP models)

– Ports can run as Ethernet or native Fibre Channel

– Ethernet ports allocated at port 1 and counts up

– Fibre Channel ports allocated at last port and counts down

– Requires a reboot to re-allocate port’s role (like UCS FI)

Page 8: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

8

Nexus 2000

• Fabric Extender (FEX)

• Acts as a remote line card of 7K or 5K chassis

• All management performed on Parent Switch

– No console or VTY ports on FEX

– NX-OS automatically downloaded from Parent

• No local switching

– Essentially a VN-Tag/802.1BR switch, not an Ethernet switch

– Traffic between local ports on FEX must flow “north” via uplink to Parent and then “south” back down

– Can impact design decision of platform placement

Page 9: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

9

Software Versions for CCIE Lab

• NX-OS v6.0(2) on Nexus 7000 Switches (6.2(6) latest)

• NX-OS v5.1(3) on Nexus 5000 Switches

• NX-OS v4.2(1) on Nexus 1000v

• NX-OS v5.2(2) on MDS 9222i Switches

• UCS Software release 2.0(1x) for UCS-6248

Fabric Interconnect

Page 10: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

10

Nexus NX-OS Basics

Nexus at its core is a Layer 2/3 Switch

Similar in many aspects to Catalyst IOS

– VLANs, Trunking, VTP, Rapid PVST, MST,

EtherChannel, PVLANs, UDLD, FHRPs, IGPs,

BGP, etc.

Key new features beyond Catalyst IOS

– FEX, vPC, Fabric Path, OTV, FC Switching, FCoE, etc

Page 11: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

11

NX-OS Port Channels/EtherChannels

• Unlike IOS, NX-OS does not support PAgP

– Channels must be statically on or LACP negotiated

no “switchport mode desireable”

– LACP must be enabled with feature lacp

• One of the “killer apps” of NX-OS is

Virtual Port Channels (vPC)

– Multi-Chassis EtherChannel (MEC/MCEC)

– Analogous to 3750 Cross StackWise Channel & 6500

Virtual Switching System (VSS)

Page 12: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

12

NX-OS Spanning Tree

• Unlike IOS, NX-OS does not support legacy CST/PVST+

– Default STP mode is Rapid-PVST+

– i.e. per-VLAN, but uses 802.1w Rapid STP

– Also supports 802.1s Multiple Spanning Tree (MST)

• NX-OS defines three STP port types

– spanning-tree port-type [normal | edge | network]

Page 13: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

13

NX-OS Switchport Types

spanning-tree port-type normal

– Normal ports act like Catalyst IOS ports

– Default STP port type, run Rapid Per VLAN STP spanning-tree port-type edge

– Edge ports are STP PortFast ports

spanning-tree port-type network

– Network ports run STP Bridge Assurance

Page 14: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

14

Bridge Assurance• All STP Network Ports send BPDUs regardless of STP port state

– Legacy 802.1d only sends BPDUs from Root Bridge downstream

– Primary goal is to protect against unidirectional links

– BPDU becomes a bidirectional keepalive

– Replaces LoopGuard functionality

• Secondary result is same functional effect as VTP Pruning

– VLANs stop forwarding on trunk links that you do not receive BPDUs for that VLAN in

• Enabled on interfaces with spanning-tree port type network

Page 15: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

15

Bridge Assurance Diagram

N5K-1 N5K-2

VLANS 10, 20, 30 VLANS 20, 30, 40

10

20

30

20

30

40

20, 30

Bridge Assurance

switchport trunk allowed vlan

Page 16: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

16

NX-OS Layer 3

Like Catalyst IOS, NX-OS supports…

– Native layer 3 routed interfaces

I.e. no switchport

Switched Virtual Interfaces (SVIs)

• I.e. VLAN interfaces

• Must be enabled with feature interface-vlan

Page 17: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

17

NX-OS Routing Protocols

• Like IOS, NX-OS supports routing with…

– Static routing

– RIPv2 & RIPng

– EIGRP & EIGRPv6

– OSPF & OSPFv3

– IS-IS

– BGP

– Policy Routing

– No network command in IGP’s, activated on link

• Not all protocols use the same license

Page 18: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

18

NX-OS VRF• Like IOS, NX-OS Virtual Routing & Forwarding Instances are used to create separate logical routing tables

– Layer 3 interfaces in different VRFs cannot exchange traffic by default

• NX-OS VRFs behave slightly different than IOS, as…

– All layer 3 interfaces are automatically in VRF table “default”

– MGMT0 is automatically in vrf “management”

– VRFs are defined as vrf context

– Static routes are defined under the vrf context

– Dynamic routing is VRF aware, but configured under the same process

– Exec mode routing-context vrf can change the default VRF for verifications

Page 19: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

19

NX-OS Redistribution

• Unlike IOS, route-maps are required to perform redistribution on NX-OS

– Same route-map match/set logic as IOS• Redistribution does not include directly connected interfaces

– Requires redistribute direct route-map…

Page 20: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

20

Fabric Path• Pre Standard version of TRILL• Essentially Layer 2 Ethernet Routing• Uses ISIS to route Layer 2 Frames instead of using STP• Can build arbitrary Topologies – Full Mesh, Partial Mesh,

Triangle, Square, etc• Adds a TTL in Layer 2• When using with vPC referred to as vPC+

Page 21: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

21

Fabric Path Configuration

• Very few commands necessary

• Enable FabricPath

– install feature-set fabricpath

– feature-set fabricpath

• Configure FabricPath VLANs

– mode fabricpath under VLAN

• Configure FabricPath Core Ports

– switchport mode fabricpath

Page 22: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

22

Virtual Device Contexts (VDC)

VDCs used to virtualize physical hardware of Nexus 7000

– Loosely analogous to SDRs in IOS XR or Contexts in ASA

• VDCs also virtualize control plane protocols of Nexus 7000

– Not analogous to VLANs or VRFs in IOS

– Separate control plane per VDC

• VLAN 40 in VDC 1 is not VLAN 40 in VDC 2

• OSPF PID 20 in VDC 1 is not OSPF PID 20 in VDC 2

Page 23: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

23

Why VDC’s?

Multiple logical roles per physical chassis

– E.g. Core & Aggregation/Distribution on same box

Multi-Tenancy

– E.g. VDCs as a managed service to customers

Test Lab Environment for later Production Use

Required for certain features – FCoE/Storage

Page 24: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

24

VDC Caveats

Some features can’t co-exist in same VDC

– OTV and VLAN interfaces (SVIs)

– F2 cards and M1/F1

– FCoE requires its own “Storage” VDC

Hardware and Software version dependent, check the release notes

Page 25: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

25

VDC Maximums

• 4 VDCs per chassis with SUP 1

• 4+1 VDCs per chassis with SUP 2

• 8+1 VDCs per chassis with SUP 2E*

• No internal cross VDC communication

– E.g. no route leaking like in VRFs

– Physical cable can be used to connect VDCs

Page 26: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

26

The Default VDC

• Default VDC “1” always exists and cannot be removed

• Used to create and manage other VDCs

– Controls VDC port allocations

• All ports allocated to default VDC at initialization

– Controls VDC resource allocations

• Number of VLANs, VRFs, Routing table memory, etc.

• Can be used for normal data plane operations

– “Recommended” for management of chassis only

Page 27: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

27

Default VDC TasksSome tasks can only be performed in the default VDC

– VDC creation/deletion/suspend

– Resource allocation – interfaces, memory, MAC’s

– NX-OS Upgrade across all VDCs

– ISSU or EPLD Upgrade

– Ethanalyzer captures – control plane traffic

– Feature-set installation for Nexus 2000, FabricPath, FCoE

– Control Plane Policing (CoPP)

– Port Channel load balancing hash

– Hardware IDS check control

– ACL Capture feature enable

– System-Wide QoS

Page 28: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

28

Converged Ethernet or FCoE

• Lots of terms that essentially mean the same thing – Unified Fabric – Unified Wire – Converged Ethernet – Converged Enhanced Ethernet – Data Center Ethernet – Data Center Bridging

• What they all really mean…– You are running the physical framing for both Ethernet and Fibre Channel over the same physical links

Page 29: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

29

FCoE Terms

• FCoE Initialization Protocol (FIP)

• FCoE Forwarder (FCF)

• ENode – End Device

• Virtual Fibre Channel (VFC) Interface

Page 30: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

30

FC, FCoE, FCIP and iSCSI

Page 31: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

31

How FCoE Works • FCoE replaces layer 1 & 2 transport for FC• All upper layer FC services remain – Domain IDs, FSPF, FCNS, FLOGI, Zoning.• New FCoE Initialization Protocol (FIP) to negotiate between Fabric and Node – Fabric is the FCF – Node is the ENode

Page 32: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

32

FCoE Control and Data Planes

• FIP is the control plane of FCoE• FCoE is the actual data plane• FIP – New EtherType 0x8914 – Used to discover FCFs and perform FLOGI _ UCS C when FCoE turned on uses LLDP to begin negotiation

• FCoE – New Ethertype 0x8906 – Min length of 2240 bytes, FC has larger payload

• Implies Jumbo Frames are required

Page 33: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

33

OTV Basics

• Overlay Transport Virtualization (OTV)

– Layer 2 VPN over IPv4

• Specifically OTV is…

– IPv4/IPv6 over Ethernet… over MPLS… over GRE…

over IPv4…

Page 34: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

34

OTV vs. other Layer 2 DCI’sLayer 2 DCI is needed for Virtual Machine Workload Mobility i.e. VMware VMotion

• Many possible options for L2 DCI

– Dark Fiber (CWDM/DWDM)

– Layer 2 Transport Protocol (L2TPv3)

– Any Transport over MPLS (AToM)

– Virtual Private LAN Services (VPLS)

– Bridging over GRE – Spanning Tree Bridge Group

• These options can be used for DCI, but OTV was made for DCI

– Optimizes ARP flooding over DCI

– Demarc of the STP domain

– Can overlay multiple VLANs without complicated design

– Allows multiple edge routers without complicated design

Page 35: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

35

OTV Terms

• OTV Edge Device

– Edge router(s) running OTV

• Authoritative Edge Device (AED)

– Active edge router for a particular VLAN

– Allows multiple redundant edge routers while preventing loops

• Extend VLANs

– VLAN being bridged over OTV

• Site VLAN

– Internal VLAN used to elect AED

Page 36: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

36

OTV Terms Continued

• Site Identifier

– Unique ID per DC site, shared between AEDs

• Internal Interface

– Layer 2 interface where traffic to be encapsulated is received

• Overlay Interface

– The logical OTV tunnel interface that performs the OTV

encapsulation

• OTV Join Interface

– The Layer 3 physical link or port-channel that you use to route upstream towards the DCI

Page 37: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

37

OTV Overview

VLANS 10 - 70

Server 1VLAN 60

Server 2VLAN 60

OTV Overview

DCIAny Layer 3 Connection

OTV OverlayLogical Address

OTV OverlayLogical Address

Join Interface Internal

InterfaceExtend VLANS50 -70

Site VLAN 4

VLANS 50 - 90

OTV OverlayLogical Address

OTV OverlayLogical Address

Site VLAN 3

AED VLANS 50 -59

AED VLANS 60 - 70

VLANS 10 - 70

VLANS 50 - 90

NK7-1-2

NK7-1-1

NK7-2-2

NK7-2-1

Page 38: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

38

OTV Control Plane

• Uses IS-IS to advertises MAC addresses between AEDs

– Is it’s own transport and extensible

• ISIS Encapsulated as Control Group Multicast

– IS-IS over Ethernet over MPLS over GRE over

IPv4 Multicast

– Implies that DCI must support ASM Multicast

Page 39: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

39

OTV Data Plane

• Uses both Unicast and Multicast Transport

• Multicast Control Group

– Multicast or Broadcast Control Plane Protocols

– E.g. ARP, OSPF, EIGRP, etc.

• Unicast Data

– Normal Unicast is encapsulated as Unicast between AEDs

• Multicast Data Group

– Multicast Data flows are encapsulated as SSM Multicast

– Implies AEDs use IGMPv3 for (S,G) Joins

Page 40: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

40

OTV Adjacency Server

• Normally OTV requires that the DCI runs multicast

– Needed to find and form IS-IS adjacencies and to tunnel

multicast data traffic

• OTV Adjacency Server removes multicast requirement

– One (or more) AEDs are configured as the adjacency server

– All other AEDs register with the adjacency server

– Now all endpoints are known

• All control and data plane traffic is now unicast encapsulated

– Will result in “Head End Replication” when more than 2 DC’s connected over the DCI

Page 41: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

41

OTV DCI Optimizations

• Other DCI options bridge all traffic over DCI

– STP, ARP, L2 Flooding, broadcast storms, etc.

• OTV reduces unnecessary flooding by…

– Proxy ARP/ICMPv6 Cache on AED

– Terminating the STP domain on AED

Page 42: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

42

vPC Port Channels

– Port Channels, EtherChannels, & NIC Teaming/Bonding terms used interchangeably

– Regardless of vendor, 802.3ad (LACP) refers to Port Channeling

• Used to aggregate bandwidth of multiple links between devices

– E.g. 4 x physical 1GigE links form a 4GigE logical Port Channel

• Appears as one logical link from STP’s perspective

– Avoids active/standby and allows active/active

Page 43: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

43

vPC Port Channels• Data flows are load balanced between member links

– Single flow cannot exceed BW of any physical member link

• E.g. increases lanes on the highway but not the speed limit

• Does not perform LFI like PPP Multilink

• Flows are load balanced based on L2, L3, & L4 header

information

– SRC/DST VLAN, MAC, IP, & TCP/UDP Port

• Default is SRC/DST L3 for IPv4/IPv6 and SRC/DST MAC

for non IP

– Can result in over/under subscribed links

Page 44: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

44

Port Channels

• Port Channeling was original between only 2 devices

– 1 downstream device & 1 upstream device

• E.g. end host to Catalyst 3550 via 2 x FE links

– Increases BW but still has single point of failure

• Multi Chassis EtherChannel (MCEC/MEC) is between

3 devices

– 1 downstream device & 2 upstream devices

• E.g. end host to 2 x Catalyst 3750s via 2 x GigE links

– Increases BW and resiliency

– Logically appears the same as a 2 device Port Channel

Page 45: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

45

Multi Chassis Ethernet Channels

• 3750 StackWise & 6500 VSS single control plane

– StackWise via Stacking Cable to connect BP

– VSS via Virtual Switch Link (VSL)

• vPC uses two separate control planes

– Configurations managed independently

– Separate control plane protocol instances

• STP, FHRPs, IGPs, BGP, etc.

– Synchronization via a Peer Link

• Similar logic to VSS’s VSL

Page 46: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

46

vPC Peer Switches

• vPC made up of 2 physical switches

– The vPC Peers

• vPC Peers each have…

– vPC Peer Link

– vPC Peer Keepalive Link

– vPC Member Ports

Page 47: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

47

vPC Overview

N5K-1 N5K-2

N7K-1N7K-2

Access Switch

Peer Link

Peer Keepalive

Member Ports Member Ports

Page 48: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

48

vPC Peer Link• Layer 2 trunk link used to sync control plane between vPC peers

– CAM table, ARP cache, IGMP Snooping DB, etc.

– Uses Cisco Fabric Service over Ethernet (CFSoE) protocol

– Used to elect a vPC Primary and vPC Secondary Role

• Normally not used for the data plane

– Peer Link generally much lower BW than aggregate of

vPC Member Ports

– If Peer Link used in the data plane, it is the bottleneck

Page 49: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

49

vPC Peer Keepalive

• Layer 3 link used as heartbeat in the control plane

– Used to prevent active/active or “Split Brain” vPC Roles

– Not used in the vPC data plane

– Uses unicast UDP port 3200

• Peer Keepalive Link can be…

– Mgmt0 port

• Back to back or over routed infrastructure

• Ideally in an isolated VRF

Page 50: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

50

vPC Member Ports

• Data plane port channel towards downstream neighbor

• Each vPC Peer has at least one member port per vPC

– Can be more, up to hardware platform limits

• From perspective of downstream neighbor, upstream

vPC Peers are one switch

– Physical result is a triangle

– Logical result is a point-to-point Port Channel with no STP blocking ports

Page 51: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

51

vPC Order of Operations

• Enable feature vpc

• Create a vPC domain

• Configure the vPC peer keepalive link

• Create the vPC peer link

• Move member ports to a vPC

– Configurations must be consistent to avoid Type 1 and Type 2 errors

Page 52: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

52

vPC Loop Prevention• Goal of vPC is to hide redundant links from STP

– Could result in layer 2 flooding loops

• Loops are prevented via “vPC Check” behavior

– Frames received in the vPC Peer Link cannot flood out a vPC

Member Port while the remote vPC Peer has active vPC

Members in the same vPC

• vPC Check Exception

– If vPC Peer’s Member Ports are down, the

vPC Member Ports become “Orphan Ports” and the

vPC Check is disabled

– vPC Peer Link is essentially a last resort connection

Page 53: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

53

vPC and FHRP• Nexus 7000 is typically L2 & L3 network boundary

– N7K is vPC Peer but also end host’s FHRP Default Gateway

• FHRP behavior changes to accommodate active/active forwarding

over vPC

– Traffic received in vPC Member Port of FHRP Standby to FHRP

Virtual MAC is not forwarded over Peer Link to Active FHRP member

– Essentially HSRP Standby acts as HSRP Active

• FHRP vPC can break in certain non-standard vendor applications

– Frames sent to FHRP Standby with physical DST MAC of FHRP

Active are sent out the Peer Link

– peer-gateway allows FHRP Standby to forward frames on

behalf of DST MAC of FHRP Active without going over Peer Link

Page 54: CISCO NX-OS DATA CENTER FEATURES Jack Ross CCIE #16728 1

54

vPC and Multicast

• When source is reachable via vPC Member Port, both vPC Peers act as PIM DR

– Called “Dual DR” or “Proxy DR”

• Allows either vPC Primary or Secondary to receive traffic from source and forward it north without having to cross the vPC Peer Link

– Respects vPC check rule