cisco ucs b230 m2 blade server spec sheet · sled-mounted choose drives the available drives are...

30
CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.21 MAY 9, 2015 WWW.CISCO.COM Spec Sheet This product has been discontinued Cisco UCS B230 M2 Blade Server

Upload: lyanh

Post on 24-May-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.21 MAY 9, 2015 WWW.CISCO.COM

Spec SheetThis product has been discontinued

Cisco UCS B230 M2 Blade Server

Page 2: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

Cisco UCS B230 M2 Blade Server2

OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Chassis Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . . 5CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

STEP 1 VERIFY BASE SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7STEP 2 CHOOSE CPU(S) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8STEP 3 CHOOSE MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9STEP 4 CHOOSE SOLID STATE DRIVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13STEP 5 CHOOSE MEZZANINE OPTION CARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14STEP 6 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . . 15STEP 7 CHOOSE OPERATING SYSTEM MEDIA KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18STEP 8 CHOOSE SERVICE and SUPPORT LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19ORDER OPTIONAL KVM CABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Motherboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25DIMM and CPU Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Memory Population Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Page 3: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

OVERVIEW

OVERVIEWThe Cisco® UCS B230 M2 Blade Server is a two-socket, half-width blade server that extends the capabilities of the Cisco Unified Computing System™, using Intel's Xeon E7-2800 and E7-8800 Series multi-core processors with 32 DIMM slots, one mezzanine slot, and up to two solid-state drives (SSDs). Up to eight half-width blade servers can be accommodated in the Cisco UCS 5108 Blade Server Chassis. The UCS B230 M2 server is shown in Figure 1.

Figure 1 Cisco UCS B230 M2 Blade Server

Cisco UCS B230 M2 Blade Server 3

Page 4: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

DETAILED VIEWS

DETAILED VIEWS

Chassis Front View

Figure 2 shows the front of the Cisco UCS B230 M2 Blade Server.

Figure 2 Chassis Front View

1 SSD 1 activity LED 9 Beaconing LED and button

2 SSD 1 Fault/Locate LED 10 System activity LED

3 SSD sled in bay 1 11 Blade health LED

4 SSD 2 activity LED 12 Reset button access

5 SSD 2 fault LED 13 Power button and LED

6 Ejector lever captive screw 14 Console connector1

Notes . . .

1. For more information regarding the KVM cable connection, see ORDER OPTIONAL KVM CABLE on page 24

7 Ejector lever 15 Asset tab2

2. Each server has a blank plastic tag that pulls out of the front panel, provided so you can add your own asset tracking label without interfering with the intended air flow

8 SSD sled in bay 2 - -

1999

80

4 6 1415

9 10 12 131

3 8 112 5 7

Cisco UCS B230 M2 Blade Server4

Page 5: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

BASE SERVER STANDARD CAPABILITIES and FEATURES

BASE SERVER STANDARD CAPABILITIES and FEATURESTable 1 lists the capabilities and features of the base server. Details about how to configure the server for a particular feature or capability (for example, number of processors, disk drives, or amount of memory) are provided in CONFIGURING the SERVER on page 6.

Table 1 Capabilities and Features

Capability/Feature Description

Chassis The B230 M2 Blade Server mounts in a Cisco UCS 5100-series chassis

CPU Either 1 or 2 Intel® Xeon® E7-2800 or E7-8800 series processors

Chipset Intel® 7510 chipset

Memory 32 slots for registered DIMMs, up to 512 GB.

Expansion slots One mezzanine slot is provided

Storage controller LSI SAS 2008 RAID controller (onboard version of LSI MegaRAID 9240)

Internal storage devices Up to two optional front-accessible, hot-swappable low-height 7 mm form factor SATA solid-state disk drives (SSDs).

Video The server CIMC chip includes a Matrox G200 core. The first 8 MB of memory are allocated to the video core.

Interfaces One front-accessible console connector (see ORDER OPTIONAL KVM CABLE on page 24)

Power subsystem Integrated in the Cisco UCS 5100 series chassis

Fans Integrated in the Cisco UCS 5100 series chassis

Integrated management processor

The built-in Cisco Integrated Management Controller (CIMC) GUI or CLI interface enables you to monitor the server inventory, health, and system event logs.

Cisco UCS Diagnostics for Cisco UCS B-Series Blade Servers

The Cisco UCS Blade Server Diagnostics tool for Cisco UCS Blade Servers enables you to verify the health of the hardware components on your servers. The diagnostics tool provides a variety of tests to exercise and stress the various hardware subsystems on the Cisco UCS Blade Servers, such as memory and CPU. You can use the tool to run a sanity check on the state of your Cisco UCS Blade Servers after you fix or replace a hardware component. You can also use this tool to run comprehensive burn-in tests before you deploy a new Cisco UCS Blade Server in your production environment.

See the following links for more information:

User Guide: http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/ucs_diagnostics/b_UCS_Blade_Server_Diagnostics_User_Guide.html

ISO Download:

http://www.cisco.com/cisco/software/navigator.html

Cisco UCS B230 M2 Blade Server 5

Page 6: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CONFIGURING the SERVER

CONFIGURING the SERVERFollow these steps to configure the Cisco UCS B230 M2 Server:

■ STEP 1 VERIFY BASE SKU, page 7

■ STEP 2 CHOOSE CPU(S), page 8

■ STEP 3 CHOOSE MEMORY, page 9

■ STEP 4 CHOOSE SOLID STATE DRIVES, page 13

■ STEP 5 CHOOSE MEZZANINE OPTION CARD, page 14

■ STEP 6 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARE, page 15

■ STEP 7 CHOOSE OPERATING SYSTEM MEDIA KIT, page 18

■ STEP 8 CHOOSE SERVICE and SUPPORT LEVEL, page 19

Cisco UCS B230 M2 Blade Server6

Page 7: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CONFIGURING the SERVER

STEP 1 VERIFY BASE SKU

Verify the product ID (PID) of the base server as shown in Table 2.

The B230-BASE-M2 base server:

■ Does not include CPUs, memory DIMMs, solid-state Drives (SSDs), or a mezzanine card.

Table 2 PID of the Base B230 M2 Server

Product ID (PID) Description

B230-BASE-M2 UCS B230 M2 Blade Server w/o CPU, memory, SSD, mezzanine

NOTE: Use the steps on the following pages to configure the server with the components that you want to include.

Cisco UCS B230 M2 Blade Server 7

Page 8: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CONFIGURING the SERVER

STEP 2 CHOOSE CPU(S)

The standard CPU features are:

■ Intel Xeon E7-2800 or E7-8800 series CPUs

■ Intel 7510 chipset

■ Cache size of 18, 24, or 30 MB

Choose CPUs

The available CPUs are listed in Table 3.

Approved Configurations

(1) One-CPU Configuration

■ Choose one CPU from Table 3.

(2) Two-CPU Configuration

■ Choose two CPUs from any one row of Table 3.

Caveats

■ You must choose one processor or two identical processors.

Table 3 Available CPUs: Intel Xeon E7-28xx/8867L Family

Product ID (PID)Intel

Number

Clock Freq(GHz)

Power (W)

Cache Size (MB)

Cores QPIHighest DDR3 DIMM Clock Support (MHz)

UCS-CPU-E78867L E7-8867L 2.13 105 30 10 6.40 13331

UCS-CPU-E72870 E7-2870 2.40 130 30 10 6.40 13331

Notes . . .

1. Maximum operational speed = 1066 MHz

UCS-CPU-E72860 E7-2860 2.26 130 24 10 6.40 13331

UCS-CPU-E72850 E7-2850 2.00 130 24 10 6.40 13331

UCS-CPU-E27830 E7-2830 2.13 105 24 8 6.40 13331

UCS-CPU-E72803 E7-2803 1.73 105 18 6 4.80 13332

2. Maximum operational speed = 800 MHz

Cisco UCS B230 M2 Blade Server8

Page 9: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CONFIGURING the SERVER

STEP 3 CHOOSE MEMORY

The standard memory features are:

■ DIMMs

— Maximum memory bandwidth: 800 MHz for E7-2803, 1066 MHz for all other CPUs

— Ranks per DIMM: 1, 2, or 4

— Operational voltage: 1.35 V

— Registered DIMMs (RDIMMs)

— Mirroring option

— Advanced error correcting code (ECC)

— Double device data correction (DDDC)

■ Each CPU controls four DDR3 channels. Each of the channels controls four DIMMs. The maximum number of DIMMs that can be installed per CPU is 16 (8 DIMM kits). See Figure 3.

NOTE: DDDC support applies to x4 DIMMs only.

NOTE: Memory mirroring is supported and settable using the UCSM Service Profile “Memory RAS Configuration” setting.

Cisco UCS B230 M2 Blade Server 9

Page 10: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CONFIGURING the SERVER

Figure 3 B230 M2 Memory Organization

Select DIMMs

DIMMs are available as two-DIMM kits. Each of the product IDs in Table 4 specifies two DIMMs.

Table 4 Available DDR3 DIMMs

Product ID (PID) PID Description VoltageRanks/DIMM

DIMM Pair Kit Options (2 DIMMs per kit)

UCS-MR-2X041RX-C 2x4GB DDR3-1333-MHz RDIMM/PC3-10600/1R/x4/1.35v 1.5/1.35 V 1

UCS-MR-2X082RX-C 2x8GB DDR3-1333-MHz RDIMM/PC3-10600/2R/x4/1.35v 1.5/1.35 V 2

UCS-MR-2x162RX-C 2x16GB DDR3-1333-MHz RDIMM/PC3-10600/2R/x4/1.35v 1.5/1.35 V 2

Cisco UCS B230 M2 Blade Server10

Page 11: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CONFIGURING the SERVER

Approved Configurations

(1) 1-CPU Configuration

■ 16 DIMMs capacity total

■ Select either four or eight DIMM kits (eight or 16 DIMMs) per CPU. The DIMMs will be placed by the factory as shown in the following table:

(2) 2-CPU Configuration

■ 32 DIMMs capacity total

■ Select either four or eight DIMM kits (eight to 16 DIMMs) per CPU. The DIMMs will be placed by the factory as shown in the following table:

Table 5 1-CPU Configuration DIMM Placement

Number of DIMMs

DIMM Placement in Numbered/Colored DIMM Slots (see Figure 7 on page 27)

81

Notes . . .

1. Four UCS-MR-2X041RX-C or UCS-MR-2X082RX-C or UCS-MR-2X162RX-C DIMM kits

(B0, B1) – (D0, D1) – blue slots; (A0, A1) – (C0, C1) - white slots

162

2. Eight UCS-MR-2X041RX-C or UCS-MR-2X082RX-C or UCS-MR-2X162RX-C DIMM kits or a combination of four UCS-MR-2X082RX-C DIMM kits and four UCS-MR-2X162RX-C DIMM kits

(B0, B1) – (D0, D1) – blue slots; (A0, A1) – (C0, C1) – white slots(B2, B3) – (D2, D3) – yellow slots; (A2, A3) – (C2, C3) - black slots

Table 6 2-CPU Configuration DIMM Placement

Number of DIMMs per CPU

DIMM Placement in Numbered/Colored DIMM Slots (see Figure 7 on page 27)

81

Notes . . .

1. Four UCS-MR-2X041RX-C or UCS-MR-2X082RX-C or UCS-MR-2X162RX-C DIMM kits per CPU

CPU 1: (B0, B1) – (D0, D1) – blue slots; (A0, A1) – (C0, C1) - white slotsCPU 2: (B0, B1) – (D0, D1) – blue slots; (A0, A1) – (C0, C1) - white slots

162

2. Eight UCS-MR-2X041RX-C or UCS-MR-2X082RX-C or UCS-MR-2X162RX-C DIMM kits per CPU or a combination of four UCS-MR-2X082RX-C DIMM kits and four UCS-MR-2X162RX-C DIMM kits per CPU

CPU 1: (B0, B1) – (D0, D1) – blue slots; (A0, A1) – (C0, C1) – white slots(B2, B3) – (D2, D3) – yellow slots; (A2, A3) – (C2, C3) - black slotsCPU 2: (B0, B1) – (D0, D1) – blue slots; (A0, A1) – (C0, C1) – white slots(B2, B3) – (D2, D3) – yellow slots; (A2, A3) – (C2, C3) - black slots

Cisco UCS B230 M2 Blade Server 11

Page 12: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CONFIGURING the SERVER

Caveats

■ The only supported DIMM configurations are shown in Table 5 on page 11 and Table 6 on page 11. The DIMMs are sold in matched pairs, which must be installed in pairs shown in the tables. Switching out one of the DIMMs within the matched pair will lead to memory errors.

■ DIMMs sold as kits are matched pairs and must remain together when installed in a particular pair of same-colored (blue, white, yellow, or black) pairs of slots.

■ The B230 M2 server needs at least four DIMM pairs installed for each CPU for optimal performance.

■ The DIMMs installed in slots for an absent CPU are not recognized.

Cisco UCS B230 M2 Blade Server12

Page 13: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CONFIGURING the SERVER

STEP 4 CHOOSE SOLID STATE DRIVES

The standard disk drive features are:

■ 7 mm low-height form factor solid state drives

■ Hot-pluggable

■ Sled-mounted

Choose Drives

The available drives are listed in Table 7.

Approved Configurations

(1) 1-Drive Configuration

■ Select one drive from Table 7.

(2) 2-Drive Configuration

■ Select two drives from Table 7.

Caveats

■ None

Table 7 Available Hot-Pluggable Sled-Mounted SSDs

Product ID (PID) PID DescriptionDrive Type

Capacity

UCS-SD300G0KA2-T 300 GB SATA 7 mm Enterprise Performance SSD SATA 300 GB

UCS-SD200G0KA2-T 200 GB SATA 7 mm Enterprise Performance SSD SATA 200 GB

UCS-SSD100GI1F105 100 GB SATA 7 mm Enterprise Performance SSD SATA 100 GB

UCS-SD400G0KA2-S 400 GB SATA 7 mm Enterprise Value SSD SATA 400 GB

UCS-SD100G0KA2-S 100 GB SATA 7 mm Enterprise Value SSD SATA 100 GB

Cisco UCS B230 M2 Blade Server 13

Page 14: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CONFIGURING the SERVER

STEP 5 CHOOSE MEZZANINE OPTION CARD

The standard PCIe card offerings are:

■ Converged Network Adapters (CNA)

■ Network Interface Cards (NICs)

Choose a PCIe Option Card

The available PCIe option cards are listed in Table 8.

Approved Configurations

(1) Select one PCIe Mezzanine Card (mandatory)

You must select one card.

To help ensure that your operating system is compatible with the card you have selected, please check the Hardware Compatibility List at this URL:

http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html

Table 8 Available PCIe Option Cards

Product ID (PID) PID Description

Converged Network Adapters (CNA)

UCSB-MEZ-QLG-031

Notes . . .

1. This new M73KR-Q adapter is the nearest equivalent replacement for the obsolete M72KR-Q adapter.

Cisco UCS CNA M73KR-Q Qlogic Adapter

UCS-VIC-M82-8P Cisco UCS VIC 1280 dual 40Gb capable Virtual Interface Card

N20-AC00022

2. The UCS M81KR VIC is no longer orderable.

UCS M81KR Virtual Interface Card/PCIe/2-port 10Gb

Cisco UCS B230 M2 Blade Server14

Page 15: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CONFIGURING the SERVER

STEP 6 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARE

Several operating systems and value-added software programs are available. Select as desired from Table 9.

Table 9 OSs and Value-Added Software (for 2-CPU servers)

PID Description Product ID (PID)

Microsoft Windows Server

MSWS-12-ST2S Windows Server 2012 Standard (2 CPU/2 VMs)

MSWS-12-DC2S Windows Server 2012 Datacenter (2 CPU/Unlimited VMs)

MSWS-12-ST2S-NS Windows Server 2012 Standard (2 CPU/2 VMs) No Cisco SVC

MSWS-12-DC2S-NS Windows Server 2012 Datacenter (2 CPU/Unlim VM) No Cisco SVC

MSWS-12R2-ST2S Windows Server 2012 R2 Standard (2 CPU/2 VMs)

MSWS-12R2-DC2S Windows Server 2012 R2 Datacenter (2 CPU/Unlimited VMs)

MSWS-12R2-ST2S-NS Windows Server 2012 R2 Standard (2 CPU/2 VMs) No Cisco SVC

MSWS-12R2-DC2S-NS Windows Server 2012 R2 Datacen (2 CPU/Unlim VM) No Cisco Svc

SUSE

SLES-SVR-2S-1G-1A SUSE Linux Enterprise Srvr (1-2 CPU,1 Phys);1yr Support Reqd

SLES-SVR-2S-1G-3A SUSE Linux Enterprise Srvr (1-2 CPU,1 Phys);3yr Support Reqd

SLES-SVR-2S-1G-5A SUSE Linux Enterprise Srvr (1-2 CPU,1 Phys);5yr Support Reqd

SLES-SVR-2S-UG-1A SUSE Linux Enterprise Svr (1-2 CPU,Unl Vrt);1yr Support Reqd

SLES-SVR-2S-UG-3A SUSE Linux Enterprise Svr (1-2 CPU,Unl Vrt);3yr Support Reqd

SLES-SVR-2S-UG-5A SUSE Linux Enterprise Svr (1-2 CPU,Unl Vrt);5yr Support Reqd

SLES-SHA-2S-1A SUSE Linux High Availability Ext (1-2 CPU); 1yr Support Reqd

SLES-SHA-2S-3A SUSE Linux High Availability Ext (1-2 CPU); 3yr Support Reqd

SLES-SHA-2S-5A SUSE Linux High Availability Ext (1-2 CPU); 5yr Support Reqd

SLES-HGC-2S-1A SUSE Linux GEO Clustering for HA (1-2 CPU); 1yr Support Reqd

SLES-HGC-2S-3A SUSE Linux GEO Clustering for HA (1-2 CPU); 3yr Support Reqd

SLES-HGC-2S-5A SUSE Linux GEO Clustering for HA (1-2 CPU); 5yr Support Reqd

SLES-SAP-2S-1G-1A SLES for SAP Applications (1-2 CPU,1 Phys); 1yr Support Reqd

SLES-SAP-2S-1G-3A SLES for SAP Applications (1-2 CPU,1 Phys); 3yr Support Reqd

SLES-SAP-2S-1G-5A SLES for SAP Applications (1-2 CPU,1 Phys); 5yr Support Reqd

SLES-SAP-2S-UG-1A SLES for SAP Applications (1-2 CPU,Unl Vrt);1yr Support Reqd

SLES-SAP-2S-UG-3A SLES for SAP Applications (1-2 CPU,Unl Vrt);3yr Support Reqd

SLES-SAP-2S-UG-5A SLES for SAP Applications (1-2 CPU,Unl Vrt);5yr Support Reqd

Cisco UCS B230 M2 Blade Server 15

Page 16: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CONFIGURING the SERVER

Red Hat Enterprise Linux

RHEL-2S-1G-1A RHEL/2 Socket/1 Guest/1Yr Svcs Required

RHEL-2S-1G-3A RHEL/2 Socket/1 Guest/3Yr Svcs Required

RHEL-HA-2S-1A RHEL Option/High-Availability/2 Socket/1Yr Svcs Required 

RHEL-HA-2S-3A RHEL Option/High-Availability/2 Socket/3Yr Svcs Required 

RHEL-RS-2S-1A RHEL Option/Resilient w/Ha /2 Socket/1 Yr Svcs Required 

RHEL-RS-2S-3A RHEL Option/Resilient Storage w/ HA /2 Socket/3 Yr Svcs Reqd 

RHEL-SFS-2S-1A RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required  

RHEL-SFS-2S-3A RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required

Nexus 1000V for Hyper-V and vSphere

N1K-VSG-UCS-BUN Over half off N1K and VSG w/ purchase of UCS B/C Series

N1K-VLEM-UCS-1 Nexus 1000V License Paper Delivery (1 CPU) for bundles

VSG-VLEM-UCS-1 VSG License Paper Delivery (1 CPU) for bundles

UCS Director

CUIC-PHY-SERV-BM-U Cisco Cloupia Resource Lic - One Phy Server node bare metal

CUIC-PHY-SERV-U Cisco Cloupia Resource Lic - One physical Server node

CUIC-TERM Acceptance of Cisco Cloupia License Terms

UCS Performance Manager

UCS-PM-IE   UCS Performance Manager

UCS-PM-EE UCS Performance Manager Express

EVAL-UCS-PM-IE  UCS Performance Manager - 60 days evaluation

EVAL-UCS-PM-EE UCS Performance Manager Express - 60 days evaluation

NFR-UCS-PM-IE UCS Performance Manager - Not For Resale

NFR-UCS-PM-EE CS Performance Manager Express - Not For Resale

IMC Supervisor

EVAL-CIMC-SUP EVAL: IMC Supervisor-Branch Mgt SW for C/E-Series - 50 Svrs

EVAL-CIMC-SUP-BAS  EVAL: IMC Supervisor One-time Site Installation License

CIMC-SUP-B01 IMC Supervisor-Branch Mgt SW for C-Series & E-Series up to 100 Svrs

CIMC-SUP-B02 IMC Supervisor- Branch Mgt SW for C-Series & E-Series up to 250 Svrs

CIMC-SUP-B10 IMC Supervisor- Branch Mgt SW for C-Series & E-Series up to 1K Svrs

CIMC-SUP-BASE-K9 IMC Supervisor One-time Site Installation License

CIMC-SUP-TERM Acceptance of Cisco IMC Supervisor License Terms

VMware 5

VMW-VS5-STD-1A VMware vSphere 5 Standard for 1 Processor, 1 Year, Support Rqd

VMW-VS5-STD-2A VMware vSphere 5 Standard for 1 Processor, 2 Year, Support Rqd

VMW-VS5-STD-3A VMware vSphere 5 Standard for 1 Processor, 3 Year, Support Rqd

VMW-VS5-STD-4A VMware vSphere 5 Standard for 1 Processor, 4 Year, Support Rqd

VMW-VS5-STD-5A VMware vSphere 5 Standard for 1 Processor, 5 Year, Support Rqd

Table 9 OSs and Value-Added Software (for 2-CPU servers) (continued)

PID Description Product ID (PID)

Cisco UCS B230 M2 Blade Server16

Page 17: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CONFIGURING the SERVER

VMW-VS5-ENT-1A VMware vSphere 5 Enterprise for 1 Processor, 1 Year Support Rqd

VMW-VS5-ENT-2A VMware vSphere 5 Enterprise for 1 CPU, 2 Yr Support Rqd

VMW-VS5-ENT-3A VMware vSphere 5 Enterprise for 1 CPU, 3 Yr Support Rqd

VMW-VS5-ENT-4A VMware vSphere 5 Enterprise for 1 Processor, 4 Year Support Rqd

VMW-VS5-ENT-5A VMware vSphere 5 Enterprise for 1 CPU, 5 Yr Support Rqd

VMW-VS5-ENTP-1A VMware vSphere 5 Enterprise Plus for 1 Processor, 1 Year Support Rqd

VMW-VS5-ENTP-2A VMware vSphere 5 Enterprise Plus for 1 CPU, 2 Yr Support Rqd

VMW-VS5-ENTP-3A VMware vSphere 5 Enterprise Plus for 1 Processor, 3 Year Support Rqd

VMW-VS5-ENTP-4A VMware vSphere 5 Enterprise Plus for 1 Processor, 4 Year Support Rqd

VMW-VC5-STD-1A VMware vCenter 5 Server Standard, 1 yr support required 

VMW-VC5-STD-2A VMware vCenter 5 Server Standard, 2 yr support required 

VMW-VC5-STD-3A VMware vCenter 5 Server Standard, 3 yr support required 

VMW-VC5-STD-4A VMware vCenter 5 Server Standard, 4 yr support required 

VMW-VC5-STD-5A VMware vCenter 5 Server Standard, 5 yr support required 

Table 9 OSs and Value-Added Software (for 2-CPU servers) (continued)

PID Description Product ID (PID)

Cisco UCS B230 M2 Blade Server 17

Page 18: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CONFIGURING the SERVER

STEP 7 CHOOSE OPERATING SYSTEM MEDIA KIT

Choose the optional operating system media listed in Table 10.

Table 10 OS Media

Product ID (PID) PID Description

RHEL-6 RHEL 6 Recovery Media Only (Multilingual)

SLES-11 SLES 11 media only (multilingual)

MSWS-08R2-STHV-RM Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media

MSWS-08RS-ENHV-RM Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media

MSWS-08R2-DCHV-RM Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media

MSWS-12-ST2S-RM Windows Server 2012 Standard (2 CPU/2 VMs) Recovery Media

MSWS-12-DC2S-RM Windows Server 2012 Datacenter (2 CPU/Unlimited VM) Rec Media

MSWS-12R2-ST2S-RM Windows Server 2012 R2 Standard (2 CPU/2 VMs) Recovery Media

MSWS-12R2-DC2S-RM Windows Server 2012 R2 Datacen(2 CPU/Unlimited VM) Rec Media

Cisco UCS B230 M2 Blade Server18

Page 19: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CONFIGURING the SERVER

STEP 8 CHOOSE SERVICE and SUPPORT LEVEL

A variety of service options are available, as described in this section.

Unified Computing Warranty, No Contract

If you have noncritical implementations and choose to have no service contract, the following coverage is supplied:

■ Three-year parts coverage.

■ Next business day (NBD) onsite parts replacement eight hours a day, five days a week.

■ 90-day software warranty on media.

■ Ongoing downloads of BIOS, drivers, and firmware updates.

■ UCSM updates for systems with Unified Computing System Manager. These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications, release notes, and industry standards.

SMARTnet for UCS

For support of the entire Unified Computing System, Cisco offers the Cisco SMARTnet for UCS Service. This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment. Access to Cisco Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world.

For UCS blade servers, there is Smart Call Home, which provides proactive, embedded diagnostics and real-time alerts. For systems that include Unified Computing System Manager, the support service includes downloads of UCSM upgrades. The Cisco SMARTnet for UCS Service includes flexible hardware replacement options, including replacement in as little as two hours. There is also access to Cisco's extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment. You can choose a desired service listed in Table 11.

Table 11 Cisco SMARTnet for UCS Service

Product ID (PID) On Site? Description

CON-PREM-B230M2 Yes ONSITE 24X7X2 B230 M2 Blade Server

CON-OSP-B230M2 Yes ONSITE 24X7X4 B230 M2 Blade Server

CON-OSE-B230M2 Yes ONSITE 8X5X4 B230 M2 Blade Server

CON-OS-B230M2 Yes ONSITE 8X5XNBD B230 M2 Blade Server

CON-S2P-B230M2 No SMARTNET 24X7X2 B230 M2 Blade Server

CON-SNTP-B230M2 No SMARTNET 24X7X4 B230 M2 Blade Server

CON-SNTE-B230M2 No SMARTNET 8X5X4 B230 M2 Blade Server

CON-SNT-B230M2 No SMARTNET 8X5XNBD B230 M2 Blade Server

Cisco UCS B230 M2 Blade Server 19

Page 20: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CONFIGURING the SERVER

SMARTnet for UCS Hardware Only Service

For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco SMARTnet for UCS Hardware Only Service. You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours. SMARTnet for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required. You can choose a service listed in Table 12.

Unified Computing Partner Support Service

Cisco Partner Support Service (PSS) is a Cisco Collaborative Services service offering that is designed for partners to deliver their own branded support and managed services to enterprise customers. Cisco PSS provides partners with access to Cisco's support infrastructure and assets to help them:

■ Expand their service portfolios to support the most complex network environments

■ Lower delivery costs

■ Deliver services that increase customer loyalty

Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high-value technical support that capitalizes on Cisco intellectual assets. This helps partners to realize higher margins and expand their practice.

PSS is available to all Cisco PSS partners, but requires additional specializations and requirements. For additional information, see the following URL:

www.cisco.com/go/partnerucssupport

The two Partner Unified Computing Support Options include:

■ Partner Support Service for UCS

■ Partner Support Service for UCS Hardware Only

Partner Support Service for UCS provides hardware and software support, including triage support for third party software, backed by Cisco technical resources and level three support.

Table 12 SMARTnet for UCS Hardware Only Service

Product ID (PID)Service Level GSP

On Site?

Description

CON-UCW7-B230M2 UCW7 Yes UC PLUS 24X7X4OS B230 M2 Blade Server

CON-UCW5-B230M2 UCW5 Yes UC PLUS 8X5XNBDOS B230 M2 Blade Server

Cisco UCS B230 M2 Blade Server20

Page 21: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CONFIGURING the SERVER

See Table 13.

Partner Support Service for UCS Hardware Only provides customers with replacement parts in as little as two hours. See Table 14.

Unified Computing Combined Support Service

Combined Services makes it easier to purchase and manage required services under one contract. SMARTnet services for UCS help increase the availability of your vital data center infrastructure and realize the most value from your unified computing investment. The more benefits you realize from the Cisco Unified Computing System (Cisco UCS), the more important the technology becomes to your business. These services allow you to:

■ Optimize the uptime, performance, and efficiency of your UCS

■ Protect your vital business applications by rapidly identifying and addressing issues

■ Strengthen in-house expertise through knowledge transfer and mentoring

■ Improve operational efficiency by allowing UCS experts to augment your internal staff resources

■ Enhance business agility by diagnosing potential issues before they affect your operations

Table 13 Partner Support Service for UCS

Product ID (PID)Service Level GSP

On Site?

Description

CON-PSJ1-B230M2 PSJ1 No UCS SUPP PSS 8X5XNBD B230 M2 Blade Server

CON-PSJ2-B230M2 PSJ2 No UCS SUPP PSS 8X5X4 B230 M2 Blade Server

CON-PSJ3-B230M2 PSJ3 No UCS SUPP PSS 24X7X4 B230 M2 Blade Server

CON-PSJ4-B230M2 PSJ4 No UCS SUPP PSS 24X7X2 B230 M2 Blade Server

Table 14 Partner Support Service for UCS (Hardware Only)

Product ID (PID)Service Level GSP

On Site?

Description

CON-PSW2-B230M2 PSW2 No UCS W PL PSS 8X5X4 B230 M2 Blade Server

CON-PSW3-B230M2 PSW3 No UCS W PL PSS 24X7X4 B230 M2 Blade Server

CON-PSW4-B230M2 PSW4 No UCS W PL PSS 24X7X2 B230 M2 Blade Server

Cisco UCS B230 M2 Blade Server 21

Page 22: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CONFIGURING the SERVER

You can choose a service listed in Table 15.

Unified Computing Drive Retention Service

With the Cisco Unified Computing Drive Retention (UCDR) Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.

Sophisticated data recovery techniques have made classified, proprietary, and confidential information vulnerable, even on malfunctioning disk drives. The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised, which reduces the risk of any potential liabilities. This service also enables you to comply with regulatory, local, and federal requirements.

If your company has a need to control confidential, classified, sensitive, or proprietary data, you might want to consider one of the Drive Retention Services listed in Table 16.

Table 15 UCS Computing Combined Support Service

Product ID (PID)Service

Level GSPOn Site?

Description

CON-NCF2-B230M2 NCF2 No CMB SPT SVC 24X7X2 B230 M2 Blade Server

CON-NCF2P-B230M2 NCF2P Yes CMB SPT SVC 24X7X2OS B230 M2 Blade Server

CON-NCF4P-B230M2 NCF4P Yes CMB SPT SVC 24X7X4OS B230 M2 Blade Server

CON-NCF4S-B230M2 NCF4S Yes CMB SPT SVC 8X5X4OS B230 M2 Blade Server

CON-NCFCS-B230M2 NCFCS Yes CMB SPT SVC 8X5XNBDOS B230 M2 Blade Server

CON-NCFE-B230M2 NCFE No CMB SPT SVC 8X5X4 B230 M2 Blade Server

CON-NCFP-B230M2 NCFP No CMB SPT SVC 24X7X4 B230 M2 Blade Server

CON-NCFT-B230M2 NCFT No CMB SPT SVC 8X5XNBD B230 M2 Blade Server

NOTE: Cisco does not offer a certified drive destruction service as part of this service.

Table 16 Drive Retention Service Options

Service DescriptionService

Program NameService

Level GSPService Level Product ID (PID)

SMARTnet for UCS Service with Drive Retention

UCS DRUCSD7 24x7x4 Onsite CON-UCSD7-B230M2

UCSD7 8x5xNBD Onsite CON-UCSD5-B230M2

Cisco UCS B230 M2 Blade Server22

Page 23: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CONFIGURING the SERVER

For more service and support information, see the following URL:

http://www.cisco.com/en/US/services/ps2961/ps10312/Unified_Computing_Services_Overview.pdf

For a complete listing of available services for Cisco Unified Computing System, see this URL:

http://www.cisco.com/en/US/products/ps10312/serv_group_home.html

SMARTnet for UCS HW ONLY+Drive Retention

UCS HW+DR UCWD7 24x7x4 Onsite CON-UCWD7-B230M2

UCWD5 8x5xNBD Onsite CON-UCWD5-B230M2

Table 16 Drive Retention Service Options (continued)

Service DescriptionService

Program NameService

Level GSPService Level Product ID (PID)

Cisco UCS B230 M2 Blade Server 23

Page 24: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

CONFIGURING the SERVER

ORDER OPTIONAL KVM CABLE

The KVM cable provides a connection into the server, providing a DB9 serial connector, a VGA connector for a monitor, and dual USB 2.0 ports for a keyboard and mouse. With this cable, you can create a direct connection to the operating system and the BIOS running on the server.

The KVM cable ordering information is listed in Table 17.

Figure 4 KVM Cable

Table 17 KVM Cable

Product ID (PID) PID Description

37-1016-01 KVM Cable

1 Connector (to server front panel) 3 VGA connector (for a monitor)

2 DB-9 serial connector 4 Two-port USB 2.0 connector (for a mouse and keyboard)

Cisco UCS B230 M2 Blade Server24

Page 25: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

SUPPLEMENTAL MATERIAL

SUPPLEMENTAL MATERIAL

Motherboard

A top view of the B230 M2 motherboard is shown in Figure 5.

Figure 5 B230 M2 Motherboard

1 DIMM slots 4 DIMM slots

2 CPU 1 and heat sink 5 Mezzanine adapter card connector

3 CPU 2 and heat sink 6 Diagnostic button

Cisco UCS B230 M2 Blade Server 25

Page 26: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

SUPPLEMENTAL MATERIAL

DIMM and CPU Layout

Each CPU controls four memory channels, as shown in Figure 6.

Figure 6 B230 M2 Memory Organization

■ CPU1: Channels A, B, C, and D

— Bank 1 - B0, B1; D0, D1 (blue DIMM slots)

— Bank 2 - B2, B3; D2, D3 (yellow DIMM slots)

— Bank 3 - A0, A1; C0, C1 (white DIMM slots)

— Bank 4 - A2, A3; C2, C3 (black DIMM slots)

■ CPU2: Channels A, B, C, and D

— Bank 1 - B0, B1; D0, D1 (blue DIMM slots)

— Bank 2 - B2, B3; D2, D3 (yellow DIMM slots)

— Bank 3 - A0, A1; C0, C1 (white DIMM slots)

— Bank 4 - A2, A3; C2, C3 (black DIMM slots)

The DIMM and CPU physical layout is shown in Figure 7. CPU 1 is located on the upper half of the board and controls the upper DIMMs. CPU 2 is located on the lower half of the board and controls the lower DIMMs.

Cisco UCS B230 M2 Blade Server26

Page 27: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

SUPPLEMENTAL MATERIAL

Figure 7 DIMM and CPU Layout

Memory Population Recommendations

Table 18 shows the preferred order for installing upgrade DIMMs, and while other configurations may work, if problems arise, moving them to the preferred arrangement should help. Note that the bank installation order is Bank 1, Bank 3, Bank 2, Bank 4.

NOTE: DIMMs installed in slots for an absent CPU are not recognized.

Table 18 Preferred DIMM Population Order

DIMMs per CPU Numbered Slots1

Notes . . .

1. The slots inside the parentheses are electrically paired with each other, and should be populated with identically matched DIMMs that were ordered as a pair. Do not swap a paired DIMM with a DIMM that is not identical in manufacturer part number.

8 (blue, white) (B0, B1) – (D0, D1) – (A0, A1) – (C0, C1)

16 (blue, white, yellow, black)

(B0, B1) – (D0, D1) – (A0, A1) – (C0, C1) –

(B2, B3) – (D2, D3) – (A2, A3) – (C2, C3)

Cisco UCS B230 M2 Blade Server 27

Page 28: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

SUPPLEMENTAL MATERIAL

When considering the memory configuration of your server, you should observe the following:

■ DIMMs within the blade server can be of a different size.

■ Your selected CPU(s) can have some effect on performance. If two CPUs are used, they must both be of the same type.

■ Performance degradation can result from the following:

— Mixing DIMM sizes and densities within a pair is not allowed and both DIMMs in the pair will be logically removed from the memory array

— Unevenly populating DIMMs between CPUs

— Populating channels with an odd number of total ranks (for example, mixing single-rank and dual-rank DIMMs)

— Using anything other than 8 or 16 DIMMs per CPU properly placed in the system

Cisco UCS B230 M2 Blade Server28

Page 29: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Dimensions and Weight

Power Specifications

For configuration-specific power specifications, use the Cisco UCS Power Calculator at:

http://ucspowercalc.cisco.com.

Table 19 UCS B200 M2 Dimensions and Weight1

Notes . . .

1. The system weight given here is an estimate for a fully configured system and will vary depending on the number of CPUs, memory DIMMs, and other optional items.

Parameter Value

Height 1.95 in. (50 mm)

Width 8.00 in.(203 mm)

Depth 24.4 in. (620 mm)

Weight 18.0 lbs (8.16 kg)*

Cisco UCS B230 M2 Blade Server 29

Page 30: Cisco UCS B230 M2 Blade Server Spec Sheet · Sled-mounted Choose Drives The available drives are listed in Table 7. Approved Configurations (1) 1-Drive Configuration

TECHNICAL SPECIFICATIONS

Cisco UCS B230 M2 Blade Server30