city of vincent · 2019-01-18 · city of vincent local planning policy 7.7.1 - non-residential...
TRANSCRIPT
$
PPM
El VCD VCD
TIV CITY OF VINCENT
DEVELOPMENT APPLICATION
Lot 216 (No. 536) Charles Street, North Perth
July 2018
DOCUMENT CONTROL
Author: J Morskate
Date Created: 10 July 2018
Project Number: 0025_18
Project Name: L216 Charles Street North Perth - DA Report
REVISION TABLE
Revision Date Purpose
v.1 26/04/2018 Client Review
v.2 10/07/2018 Revised Plans
COPYRIGHT
This document remains the property of MPPM - Morskate Planning and Project Management. The document may only be used for the purpose for which it is commissioned. Use of this document in any other form is prohibited.
MORSKATE PLANNING & PROJECT MANAGEMENT
PH: 0423276899 ADDRESS: P 0 Box 96 Willetton 6955 EMAIL:
CONTENTS
1.0 Introduction
1.1 Background
1.2 Land Use
1.3 Utilities and Services
2.0 Proposed Development
3.0 Planning Context
3.1 City of Vincent Town Planning Scheme No.2
3.2 State Planning Policy 3.1: Residential Design Codes of Western Australia & Local Planning Policy Requirements:
City o f Vincent Local Planning Policy 7.1.1 - Built Form
City o f Vincent Local Planning Policy 7.5.10 - Sustainable Design
City o f Vincent Local Planning Policy 7.7.1 - Non-residential Development Parking Requirements
3.3 Planning Control Area No. 125 - Charles Street
3.4 State Planning Policy No. 7.3: Residential Design Codes Guidance for multiple-dwelling and mixed-use developments —Apartment Design
3.5 WAPC State Planning Policy No. 3: Urban Growth and Settlement
3.6 Perth and Peel @ 3.5 Million - Central Sub-Regional Framework
4.0 Conclusion
FIGURES
Figure 1: Property Map
Figure 2: Scheme Map
1.0 INTRODUCTION
Morskate Planning and Project Management (MPPM) has been engaged by the owner of Lot 216
(No. 536) Charles Street, North Perth (the site) to prepare a development application for a mixed
use development, consisting of three (3) multiple dwellings and two (2) commercial units. The
proposed development is consistent with the City's new Local Planning Scheme and Policy
framework, addressing the urban design provisions and expectations of the City in respect to a
sustainable mixed use development.
The proposal seeks to achieve the desired urban design outcome established by the statutory
requirements of the City and State government policy. It is therefore respectfully requested that
the City approve the proposal in the context of the intended urban design and visual amenity
outcomes which will be achieved through development of the site.
1.1 Background
The site is zoned Residential R60-100 pursuant to City of Vincent Town Planning Scheme No. 2,
identified as Lot 216 (No. 536) Charles Street, North Perth (Figure 2 - Location Plan).
132 '
523 542 421
130A 421A 419
521A-D 415 130 540 417
94 413 - 128 92 411 1-31519
536 90 T 126 88
517 A 534 81 8 8 1 2 4
5 3 2 7 9 84 405403 511-513 528A 82 401
122 5 80 6.8 511-513 78 399
120 526 75 76 397
511-513 524 74 73 72
118 522 71 70 520 68
71A 69 Figure 1 - Property Map Extract (City o f Vincent Intramaps)
- -
The subject site has an area of 407m' with frontage to Charles Street, Hilda Street and Lawler Street.
The site is on a key transport corridor within close proximity to the Perth Central Business District,
established public open space and educational facilities.
R3014
R60-RI 00
R60
R30140 7 t9
R60-R100
R30140 Figure 2— Local Planning Scheme No.2 Map (City o f Vincent)
1.2 Land Use
The subject site contains an existing dwelling and associated ancillary buildings. Land uses surrounding
the site are medium to high density mixed use development, grouped and multiple dwellings.
1.3 Utilities and Services
The subject site is currently serviced by reticulated water and sewerage, electricity and
telecommunications. On-site retention of stormwater is the current method of drainage
management.
2.0 PROPOSED DEVELOPMENT
The proposed development will involve the demolition of the existing residential dwelling and
ancillary structures to facilitate a mixed use residential and commercial development, consisting of
three (3) multiple dwelling and two (2) commercial units.
The submission is consistent with the deemed to comply requirements of the R-codes, adopted local
policy and contemporary mixed use design guidelines. The design results in a sustainable, high quality
inner city urban design and streetscape outcome which balances a high level of amenity with
functional design.
3.0 PLANNING CONTEXT
3.1 City o f Vincent Town Planning Scheme No. 2 & Local Planning Strategy
The subject site is zoned Residential R60-100 pursuant to the Scheme, located in the North Perth
Precinct. The local Scheme provisions relevant to this proposal are as follows:
Clause 4.2 Objectives
The objectives o f the zones are -
(a) Residential -
(I) to promote and encourage design that incorporates sustainability principles, including but not
limited to solar passive design, energy efficiency, water conservation, waste management and
recycling;
(ii) to enhance the amenity and character o f the residential neighbourhood by encouraging the
retention o f existing housing stock and ensuring new development is compatible within these
established areas;
(iii) to manage residential development in a way that recognises the needs o f innovative design and
contemporary lifestyles;
(iv) to ensure the provision o f a wide range o f different types o f residential accommodation, including
affordable, social and special needs, to meet the diverse needs o f the community.
'Clause 5.3.3 Special Application o f Residential Design Codes
(a) Within the area coded R60-RIOO along Charles Street in the North Perth Precinct, development will
only be permitted to R100 standards where the lot area is greater than 2,000 square meters.'
Clause 5.3.4 The Local Government may impose maximum residential car parking requirements as
outlined in the relevant Local Planning Policy.
The City of Vincent Local Planning Strategy sets the key expectations in respect to development along
Charles Street as noted in the following statement: High density mixed use and high density residential
development will be specifically targeted and located within close proximity to train stations and along
high frequency bus routes by applying the principles o f Transit Oriented Development (TOO).'
The sliding density for development along transit corridors like Charles Street facilitate high amenity
inner city development. The proposal seeks to utilise the sliding density approach consistent with the
R60-R100 coding, where in consultation with City staff it is considered that an R80 coding is
appropriate for the site.
3.3 Planning Control Area No. 125 - Charles Street
The Charles Street frontage of the site is within Planning Control Area No. 125 (PCA 125) which is in
place to allow for the final design of the Charles Street widening. PCA 125 is intended to ensure that
no development occurs on this land which may prejudice the Charles Street design until reserved for
Primary Regional Road in the Metropolitan Region Scheme.
The proposal adequately addresses PCA 125 catering for the future road widening in accordance with
the amending plan adopted by the WAPC.
3.4 State Planning Policy No. 7.3: Residential Design Codes Guidance for multiple-dwelling and
mixed-use developments - Apartment Design
The objectives of draft SPP 7.3 for apartment and mixed-use development demonstrate the
consistency of the proposed development with contemporary design measures of the State:
' - To provide residential development o f an appropriate design f o r the intended residential purpose,
density, context o f place and scheme objectives.
- To encourage design consideration o f the social, environmental and economic opportunities
possible from new housing and an appropriate response to local context.
- To encourage design which considers and respects heritage and local culture.
- To facilitate residential development which offers future residents the opportunities f o r better living
choices and affordability when seeking a home, as well as reduced operational costs and security of
investment in the long term.
The proposal seeks to provide a sustainable mixed use development which provides housing diversity
and commercial development opportunities in an inner city area.
3.5 State Planning Policy No. 3: Urban Growth and Settlement
The overarching aim of SPP 3 is to facilitate sustainable patterns of urban growth and settlement by
setting out the requirements for sustainable communities and the broad policy in accommodating
growth and change. A key objective of SPP 3 relevant to this proposal is promoting the development
of sustainable and liveable neighbourhoods which provide choice and create an identifiable sense of
place for a community.
Clause 5 of SPP 3 further supports the consolidation of existing residential areas through the following
relevant policies measures:
(i) facilitating the most efficient use of land in existing urban areas through the use of vacant and
under-utilised land and buildings, and higher densities where these can be achieved without
detriment to neighbourhood character and promoting and encouraging urban development that is
consistent with the efficient use of energy;
(ii) a positive planning framework which seeks to actively facilitate and promote good quality
development, rather than overly focussing on regulation and controls, in ways which contribute to
economic growth, support safe, sustainable and liveable communities, and improve the quality of life,
and with community involvement appropriate to the level of planning;
(iii) consolidating residential development in existing areas and directing urban expansion into the
designated growth areas which are, or will be, well serviced by employment and public transport; and
(iv) giving priority to infill development in established urban areas, particularly through urban
regeneration and intensification of development of under-utilised urban land, whilst respecting
neighbourhood character.
In this context, the proposal is consistent with the policy measures outlined in SPP 3. The development
is a proactive approach to consolidation of an existing under-utilised portion of residential land in an
area which has an established precedent of high density development in close proximity to public
transport, employment and educational facilities.
The proposal will have a positive impact upon neighbourhood character and is consistent with similar
lots and development within immediate proximity of the subject site.
3.6 Perth and Peel @ 3.5 Million - Central Sub-Regional Framework
The framework supports a more compact and environmentally sustainable city however
acknowledges that land and infrastructure need to be utilised in an efficient, integrated manner and
manage the expansion of the urban zone in balance with urban infill projects. The proposal will provide
high quality inner city housing in addition to high street commercial floorspace consistent with the
overarching objectives of Perth and Peel @ 3.5 Million.
4.0 CONCLUSION
It is considered that the proposal is well justified in the context of the current planning framework,
overarching Scheme objectives and local context.
In summary, the proposal is consistent with:
• the R60-R100 coding (applying an R80 coding), pursuant to Town Planning Scheme No. 2;
• the 'deemed to comply' and 'design principles' of the R-codes;
• the local policy intent of the City of Vincent, namely in preserving and improving built form and
urban design; and
• the provisions of relevant adopted and draft State Planning Policy and Perth and Peel @ 3.5 Million
regarding urban consolidation and sustainable use of inner city land in the Perth Metropolitan
Area.
It is therefore respectfully requested that the proposal be conditionally approved by the City of
Vincent.
26 October 2018
City of Vincent PO Box 82 Leederville WA 6902 Attn: Clair Morrison Dear Clair, PROPOSED MIXED USE DEVELOPMENT – LOT 216 (NO. 536) CHARLES STREET, NORTH PERTH On behalf of the applicant (Perth Residential Developments), I refer to the aforementioned proposal, recent meeting and correspondence with City representatives. In addition to providing a response to the delegated officer’s assessment, this response also addresses key points raised by City staff prior to and post lodgement which have influenced the design outcome. City representatives have committed to working with the applicant to achieve a development outcome on the subject site which is conducive to inner city living on a prominent, activity corridor and this response is framed in that context. It is the expectation of the applicant that the City base its assessment on the endorsed statutory provisions of the Scheme and not the philosophical position of City representatives in respect to perceived unwritten intent of the Scheme text. Definition of Sliding Density During a pre-lodgement meeting in April 2018 to discuss the plans with City representatives, it was recommended that the applicant await adoption and endorsement of Town Planning Scheme No. 2 prior to lodgement as the site would be rezoned from R60, to a sliding density R60 – R100. Based upon this advice, the applicant postponed lodgement until such time as the new scheme was endorsed and applied the ‘sliding density’ to the proposed development fitting within the R60 – R100 coding parameters, with a nominated R80 coding based upon location and lot size. Following lodgement and subsequent preliminary assessment of the application, the City’s delegated officers have now advised that the Scheme was drafted and endorsed in error in respect to the R60 – R100 sliding density, noting the intent was not for a sliding density but for an R60/R100 coding. It should be noted that in all other jurisdictions within the Western Australian Planning Framework R60/R100 is a ‘dual density’ coding – not a ‘sliding density’ as endorsed under the current Scheme. Further to this City representatives have recently referenced the Special Council meeting of 28 October and 18 November 2014 in an attempt to reinforce the philosophical position. It is noted from review of the agenda and minutes that the Charles Street ‘sliding densities’ were
considered and the concerns raised in respect to the interface with R100 and lower density R40, however there was no reference to the intent of the sliding density being a dual density coding. The Special Council meeting minutes clearly establish that the intent of sliding densities across precincts within the City was not limited to the lower or higher coding (as would be expected of an R60/R100 coding), but to a range of densities between R60 – R100. The City has the relevant head of power under the adopted and endorsed statutory planning framework to consider this proposal at an R80 density, within the remit of the allocated R60 – R100 sliding density. While the applicant is willing to address practical design requirements raised through the impending consultation process it is respectfully requested that the City uphold the statutory provisions of the Scheme and facilitate consideration of the proposal under the R60 – dR100 sliding density, through application of an R80 coding. Please do not hesitate to contact the undersigned if you wish to discuss further on 0423 276 899 or via email [email protected]. Yours sincerely
Jared Morskate BA (Hons) Urban and Regional Planning MSc (Project Management)
Deemed-to-Comply provision Required Proposed Comment
Residential Design Codes Clause 6.1.3 Street Setback
Charles Street
2m
Nil (after Charles Street Widening)
Commercial units with direct frontage to Charles Street (in consideration of the PCA and future road widening) were supported in all pre-lodgement discussions with the City.
All residential setbacks were proposed in the context of the design principles whereby the building:
- contributes to the desired streetscape for inner-city development on a designated activity corridor;
- provides articulation of the building through architectural features on the primary and secondary streets;
- includes minor projections that add interest and reflect the character of the street and locality;
- is appropriate to its location, respecting the adjoining existing development and existing streetscape by maximising the setbacks to neighbours; and
- facilitates the provision of weather protection where appropriate.
Hilda Street
2m
Ground Floor
Nil
First Floor
Nil
Lawler Street
2m
First Floor
Nil to 1.2m
Second Floor
Nil to 1.7m
Residential Design Codes Clause 6.1.4 Lot Boundary Setbacks
Southern Lot Boundary – First Floor Balcony
1.2m
1m Minor variations to the two referenced lot boundary setbacks are proposed and again are consistent with the design principles of 6.1.4, where the building is setback to:
- ensure adequate daylight, direct sun and ventilation; - reduce the visual impact of building bulk on a neighbouring
property; - ensure access to daylight and direct sun to adjoining
properties; and Residential Design Codes Clause 6.1.4 Lot Boundary
Northern Lot Boundary Permitted Length
20.24m
20.7m
Setbacks (Walls Built to Lot Boundary)
Maximum Height
3.5m
Ground Floor South
3.6m
First Floor South
5.8m
First Floor North
7.1m
- assist with the protection of privacy between adjoining properties.
As a mixed use development, in addition to the above:
- the side boundary setbacks to the commercial component of the development is in accordance with the existing street context of the commercial tenancies adjacent; and
- the commercial units have been designed to minimise the potential impacts between the two uses.
Average Height
3m
Ground Floor South
3.45m
First Floor South
5.65m
Ground Floor North
3.1m
First Floor North
6.55m
Residential Design Codes Clause 6.1.5 Open Space
45% 6.9% In the context of the provision of commercial units, the loss of land associated with the PCA and future road widening a variation to open space has been proposed. As a mixed use inner city development on a designated activity corridor it is considered that the open space requirements under an R80 coding should be applied.
Policy 7.1.1 Built Form Clause 4.10 Landscaping
Deep Soil Zone
15%
2%
The applicant can increase the deep soil zone for plantings and landscaping within the development, however the local policy provisions are contrary to the practical realities of the site, coding and adjoining streetscape. With direct commercial frontage to Charles Street and a PCA designated in the front setback a 50% landscape requirement is considered impractical and inconsistent with the surrounding streetscape.
50% of front setback to be provided as soft landscaping
Nil
30% of the site area to be provided as canopy coverage
Nil
Policy 7.7.1 Non-Residential Development Parking Requirements
Unable to be determined
Notwithstanding several meeting pre-lodgement with the City to agree on parking provisions, further discussions with the City post preliminary assessment have confirmed that reciprocal access can be provided between commercial and residential tenancies through an adopted parking plan.
Residential Design Codes Clause 6.3.6 Site Works
Fill up to 0.5m Fill up to 0.6m Maximum finished ground levels can be conditioned and will be subject to site conditions and access requirements.
Residential Design Codes Clause 6.4.2 Solar Access for Adjoining Sites
50% of Southern (Parent) Lot
65% of Southern (Parent) Lot
It is anticipated that solar access requirements can be achieved on the site through review of the overshadowing assessment.
Residential Design Codes Clause 6.4.3 Dwelling Size
Minimum 1 One-Bedroom required
No One-Bedroom proposed
Considered in the overall design philosophy for the site and contend that rigid application of the R-codes in respect to provision of a 1 bedroom unit is impractical.
Built Form Policy Clause 4.21 External Fixtures
No details on external fixtures
Can be provided for through detailed design as part of the building permit process and are not pertinent to determination of the application.
Solar Collectors required None proposed Minimum requirements for solar collectors can be provided for as a condition of approval.
Residential Design Codes Clause 6.4.5 External Fixtures, Utilities and Facilities
Clothes drying facilities No details on clothes drying facilities
Can be provided for through detailed design as part of the building permit process and are not pertinent to determination of the application.
Policy 7.1.1 – Built Form Clause 4.23 Environmentally Sustainable Design
Development must demonstrate that: P1.8.1 It maximises passive solar heating, cooling, natural ventilation and light penetration to reduce energy consumption; P1.8.2 It is capable of recovery and re-use of rainwater, storm water, grey water and/or black water for non-potable water applications. P1.8.3 Climate moderation devices can be incorporated to reduce passive solar gain in summer and increase passive solar gain in winter. P1.8.4 That it is capable of achieving one of the environmental performance ratings shown in the table of Clause 1.8 of the Built Form Policy.
Elements of the City’s local Environmentally Sustainable Design policy provisions can be included through detailed design between planning and building permit processes. The development is capable of incorporating any of the design measures referenced in the policy and will meet energy efficiency criteria, however there is a need to consider practicality and cost-effectiveness instead of the rigid application of local policy requirements.
oe ~10-01
LOT 216 (#536) CHARLES STREET- NORTH PERTH
PERSPECTIVE (CNR CHARLES ST & HILDA ST)
p
PRD - JOB # 17133
0111:1 111*11
ti± t i ; I
V
I jil Uriu I414h1
LOT 216 (#536) CHARLES STREET - NORTH PERTH
PERSPECTIVE (CNR HILDAST& LAWLERST)
PRD - JOB # 17133
DATE: 07/06/2018
COLOUR AND MATERIALS SCHEDULE CLIENT: NGUYEN
JOB NUMBER: 17133
ADDRESS: LOT 216 (#536) CHARLES STREET - NORTH STREET
EXTERIOR MATERIAL/TYPE COLOUR
ROOFING COLORBOND/ TRIMDEK MONUMENT WALLS (TYPICAL) SAND CEMENT RENDER DULUX SNOW SEASON WALLS (FEATURE) CERAMIC SUBWAY TILES GREY! WHITE CONTRAST GROUT WALLS (CLADDING) CEMENT COMPOSITE! SCYON DULUX TIMELESS GREY WINDOW FRAMES ALUMINIUM! POWDERCOATED MONUMENT MATT BLACK GUTTERS COLORBOND! SQUARELINE MONUMENT FASCIA/ FLASHING COLORBOND MONUMENT DOWNPIPES COLORBOND! RECTANGULAR TO SUIT WALL COLOUR PAVING CEMENT! BLOKPAVE SILVER HANDRAIL ALUMINIUM! POWDERCOATED MONUMENT MATT BLACK BALUSTRADE FRAMELESS GLASS PANELS CLEAR POSTS STEEL! PAINTED MONUMENT MATT BLACK SHADE BLADES ALUMINIUM! POWDERCOATED MONUMENT MATT BLACK AWNINGS STEEL! PAINTED TBC FENCING SCREENS SLATTED ALUMINIUM! P'COATED MONUMENT PRIVACY SCREENS LASER CUT STEEL! P'COATED BRONZE BOUNDARY FENCING COLORBOND! NEETASCREEN MONUMENT
.
1:200cJ/N: DATE: DRAWN:SCALE:
Licensed Surveyors
87-89 Guthrie Street, Osborne Park, Western AustraliaTelephone: (08) 9446 7361 Facsimile: (08) 9445 2998
Email : [email protected] Website: www.cottage.com.au
Lot boundaries drawn on survey arebased on landgate plan only. Survey does notinclude title search and as such may not showeasements or other interests not shown on plan.Title should be checked to verify all lot detailsand for any easements or other interests whichmay affect building on the property.
Survey does not include verification of cadastralboundaries. All features and levels shown arebased on orientation to existing pegs and fences only which may not be on correct cadastral alignment.Any designs based or dependent on the location ofexisting features should have those features'location verified in relation to the true boundary.
Survey shows visible features only and will notshow locations of underground pipes or conduitsfor internal or mains services. Verification ofthe location of all internal and mains servicesshould be confirmed prior to finalisation of anydesign work.
Cottage & Engineering surveys accept noresponsibility for any physical on site changes tothe parcel or portion of the parcel of land shownon this survey including any adjoining neighbourslevels and features that have occurred after thedate on this survey. All Sewer details plottedfrom information supplied by Water Corporation.
DISCLAIMER:
DISCLAIMER:
DISCLAIMER:
DISCLAIMER:
SEC DomePower PolePhone Pits
LEGEN
D
T C
T P10.00T WT RT F
[[[[
10.0010.0010.00
]]]]
Top Pillar/PostTop WallTop RetainingTop Fence
W Water Conn.
Due to lack of survey marks/pegs, all building offsetdimensions & features are approximate only andpositioned from existing pegs/fences and walls whichmay not be on the correct alignment and are to beverified when repegged. Any design that involvesadditions to any structures shown or portion of structuresremaining after any demolition has taken place requires
DISCLAIMER:
boundaries to be repegged and exact offsets provided to your designer/architect before any plans are producedand before any work is started on site.
OLDAREA
TELSTRA/COMMS. PIT NOT LOCATEDADJACENT TO LOT AT TIME OF SURVEY.VERIFY AVAILABILITY WITH TELSTRA.
NOTE:
Scale 1:200
0 2 4 6 8
W
S
E
N
427466 14 Nov 17 M. Bateman
Builder : Perth Residential DevelopmentsCLIENT : NguyenLOT 216 #536 Charles Street, North Perth
Plan2672
36.4
9
90°0'0"
12.19
90°0
'0"
30.3
6
116°44'0"
13.66
63°1
6'0"
8.2
3
8.20
10.13
8.4
68.3
18.298
.30
8.46
8.36
8.6
0
8.58
8.33
8.2
7
8.3
0
10.04
8.2
68.
21
8.02
10.1
4
8.3
1
8.42
8.45
8.28
8.178.13
8.17
8.22
8.338.
288.3
7 8.38 8.
348.
38
8.48
8.5
2
8.56
8.6
0
8.5
28
.59
8.7
2
8.6
6
8.98
10.30
8.7
98
.93
9.0
3
9.12
9.2
79.1
8
9.3
0
9.3
1
9.47
9.54
9.5
4
9.4
6
9.7
19.6
0
9.9
0
9.7
9
9.8
9
9.9
6
10.00
9.91
9.90
9.6
2
10.74
9.269.51
9.23
9.13
10
.66
8.9
8
10.48
9.819.79
10.7
6
9.82
9.84
9.84
10.20
10.05
10.20
10.07
10
.74
9.55
9.80
11.39
9.76
10.0
1
10.15
8.2
08
.86
9.1
3
9.6
2
9.4
2
9.2
0
8.50
0.018 mLOT MISCLOSE
Charles StreetBitumen
Non-Mount
Nil
SOIL DESCRIPTIONSandRefer to Survey
Porch
GalvPatio
Car
port
Ap
pro
x F
.L8
.33
Gro
und
Flo
or
Firs
t Flo
or
BrickWall
Bri
ck &
Gal
vG
ara
ge
Po
ss P
ara
pet W
all
Galv PatioOn Concrete
Ste
ps
Landing
Approx F.L @Door On Conc.
9.59
Approx F.L @Door On Timber
9.66
Porch Me
ter
Box
(Ele
c.)
M
Me
ter
Box
(Ga
s)G
TF[ ]
TF[ ]
TF
[]
T W[ ]
FibroFence FairCondition
Co
nc.
& L
/Gra
ss
TP[ ] Metal Rail OnBrick Wall With
Pillars
Non-Mount
Mountable
Non
-Mou
nt
No
n-M
ount
Non-Mount
Nil
Nil
Bitumen
Crossovers
L/Grass
Non-MountL/Grass
ConcreteFootpath
Concrete Footpath
Concrete Footpath
L/Grass ConsumerPole
L/G
rass
Verge TreeØ 0.42mHt 5.0m
Verge TreeØ 0.05mHt 3.0m
Str
eet
Sig
n
PowerPole(H/T)
Pow
er P
ole
Opp
.
>>>>>>
Str
eet
Sig
n
Bitu
men
Hilda S
treet
Bitu
men
Sp
ee
d H
ump
Lawler Stre
et
Bitumen
TF[ ]
TW
[]
TW
[
]
W
Met
er
Conc.Wall
Conc.Wall
Co
ncr
ete
Pat
h
L/Grass
L/Grass
Sla
bs &
L/G
rass
Gate
Fib
ro F
ence
Fa
ir C
ond
ition
(Ca
ppe
d)
TF[ ]
TimberPatio
Pon
d
TF
[
]Fibro Fence
Fair Conditio
n
(Capped)
Gate
Gate
SlabsBu
shy
Ga
rden
SewerM/H (8.18)
Sewer JunctionInv: 6.6 Depth: 1.6NOTE: UP
PEGGONE
PEGGONE
PEGGONE
PEGGONE
TreeØ 0.3mHt 4.0m
8.5
8.5
9.0
9.5
10.010.0
9.0
9.5
9.5
NOTE/BEWARE:ADVISE TRADESO/Head power lines
ConsumerOverheadPower Cable
Clo
sest W
ir e To B
ounda ry
Gate
Brick & TileOn Limestone
Brick & TileOn Limestone
(F.L Unobt.Locked Gate)
#534
#536
2-Storey Brick & Tile On Slab
Ref Nail At Base Of KerbAssumed Datum 10.00 m
DISCLAIMER:HIGH TENSION POWER LINES. CHECK TITLE FOREASEMENTS AND WESTERN POWER FOR SET-BACKS.
W
S
E
N
LEGENDDEEP SOIL LANDSCAPING
SUPPLEMENTARY LANDSCAPING
GRASSED VERGE
11.7 m² 10.7 m²
16.6 m²
2.8 m²
1.8 m²
1.6
m²
2.5
m²
4.3
m²
BINS
BINS
LANDSCAPE CONTEXTPLAN 1:200
Charles Street
Hild
a S
treet
Lawler Street
CONCEPT DESIGN
CONCEPT SCHEME 4 revA
07/10/17
09/03/18CONTEXT
CONCEPT SCHEME 4 revB 22/05/18CONCEPT SCHEME 4 revC 19/06/18CONCEPT SCHEME 4 revD 12/11/18
COPYRIGHT PERTH RESIDENTIAL DEVELOPMENTSA.B.N. 65 582 662 731
307 SELBY ST OSBORNE PARK WA 6017PH: 9204 3655 E: [email protected] DATE...............................................
BUILDER.........................................
DATE...............................................
CLIENT............................................
DATE...............................................
CLIENT............................................
JOB No.:
MAP REF.:SHEET No.:
ENG. DETAIL:WIND RATING:COASTAL CAT:
ADDRESS:
CLIENT: DATEDRAFTING LOG
LOT 216 (# 536)CHARLES ST.NORTH PERTH
THI LOAN TRAMNGUYEN
171333
Scale 1:200
0 2 4 6 8
W
S
E
N
36.4
9
90°0'0"
12.1990°0
'0"
30.3
6
116°44'0"
13.66
63°1
6'0"
8.2
3
8.20
10.13
8.4
68.3
1
8.298.3
0
8.46
8.6
0
8.33
8.2
7
8.3
0
10.04
8.2
6
8.21
8.02
8.31
8.42
8.45
8.28
8.178.13
8.17
8.22
8.338.28
8.37 8.3
8 8.34
8.38
8.48
8.5
2
8.56
8.60
8.5
28.5
98.7
28.6
6
8.98 8
.79
8.9
39.0
3
9.12
9.2
79.1
8
9.3
0
9.3
1
9.47
9.54
9.5
49.4
6
9.71
9.60
9.9
09.7
9
9.89
9.96
10.00
9.91
9.90
9.6
2
10.74
9.269.51
9.239.13
10.6
6
10.48
9.819.79
10.769.82
9.84
9.84
10.2010.05
10.2010.07
10.7
4
9.55
9.80
11.39
9.76
10.01
10.15
8.2
08.8
69.1
3
9.62
9.42
9.2
0
COMMERCIAL"A"
COMMERCIAL"B"
ST ST ST
COMM
RES
RES.
RES.
WC
BINS
3.7m
FL: 9.800
FL: 9.800
9.628
DRIVEWAY
R60 - R100
TOTAL SITE AREA : 407 m²EFFECTIVE SITE AREA : 344 m²
PLOT RATIO: 1.0 of 407 m² = 407 m²284.9 m² PROVIDED (0.7)
OPEN SPACE: 45% REQUIRED120 m² of 407.7m² PROVIDED (29.4%)
CARPARKING:
3 x RES. UNITS @ 1.0 BAYS = 3 BAYS2 x COMM. UNITS @ 1.0 BAYS = 2 BAYS5 CAR BAYS REQUIRED - 5 BAYS PROVIDED
BICYCLE PARKING @ 1 PER 3 DWELLINGS1 PROVIDEDVISITOR BICYCLE PARKING @ 1 PER 10 DWELLINGS1 PROVIDED
DEVELOPMENT SUMMARY
COMM
ACCE
SS L
EG
1
SITE PLAN07/10/17CONCEPT DESIGN
09/03/18CONCEPT SCHEME 4 revA
COPYRIGHT PERTH RESIDENTIAL DEVELOPMENTSA.B.N. 65 582 662 731
307 SELBY ST OSBORNE PARK WA 6017PH: 9204 3655 E: [email protected] DATE...............................................
BUILDER.........................................
DATE...............................................
CLIENT............................................
DATE...............................................
CLIENT............................................
JOB No.:
MAP REF.:SHEET No.:
ENG. DETAIL:WIND RATING:COASTAL CAT:
ADDRESS:
CLIENT: DATEDRAFTING LOG
LOT 216 (# 536)CHARLES ST.NORTH PERTH
THI LOAN TRAMNGUYEN
17133
Charles StreetBitumen
Non-Mount
Nil
Porch
GalvPatio
Carp
ort
Appr
ox F
.L8.
33
Gro
und
Floo
r
Firs
t Flo
or
BrickWall
TF[ ]
TF[ ]TF[
]
TW[ ]
FibroFence FairCondition
TP[ ] Metal Rail OnBrick Wall With
Pillars
Non-Mount
Mountable
Non-
Moun
t
Non-
Mou
ntNon-Mount
Nil
Nil
EXISTING
Bitumen
Crossovers
L/Grass
Non-MountL/Grass
ConcreteFootpath
Concrete Footpath
Concrete Footpath
L/Grass ConsumerPole
L/G
rass
Verge TreeØ 0.42mHt 5.0m
Verge TreeØ 0.05mHt 3.0m
Stre
et S
ign
PowerPole(H/T)
Pow
er P
ole
Opp
.
Stre
et S
ign
Bitu
men
Hild
a S
treet
Bitu
men
Spee
d Hu
mp
Lawler Street
Bitumen
TF[ ]
TW[]
TW[]
W
Met
er
Conc.Wall
Conc.Wall
Fibr
o Fe
nce
Fair
Con
ditio
n
SewerM/H (8.18)
Sewer JunctionInv: 6.6 Depth: 1.6NOTE: UP
PEGGONE
PEGGONE
PEGGONE
PEGGONE
8.5
8.5
9.0
9.5
10.010.0
9.0
9.5
9.5 ConsumerOverheadPower Cable
Closest Wire To Boundary
Gate
Brick & TileOn Limestone
Brick & TileOn Limestone
(F.L Unobt.Locked Gate)
#534
#536
2-Storey Brick & Tile On Slab
Ref Nail At Base Of KerbAssumed Datum 10.00 m
FUTUREROAD WIDENING
SITE PLAN
VEHICLE
APPT.ENTRY
COMM
ENTRY
5400
8090
3210
1610
0
CONCEPT SCHEME 4 revB 22/05/18CONCEPT SCHEME 4 revC 19/06/18
BINS
BINS
71.2 m²+ 54.6 m²
TOTAL 373.7 m² 5.2 m² 41.4 m² 13.8 m² 84.2 m²
13.5 m²---B 50.2m²NLA
13.5 m²---A 43.8m²NLA
27.0 m²
16.7 m²
4.6 m² 13.5 m²
4.6 m²
PARKINGSTORE
9.3 m²+ 9.2 m²5.2 m²3
12.0 m²-73.6 m²2
10.6 m²-1
UNIT # BALCONYSTAIR
80.3 m²
AREA
4.6 m²
CANOPY OVER
CANOPY O
VER
CAN
OPY
OVE
R
5.4 x 2.55.4 x 2.5 5.4 x 2.55.4 x 2.5 5.4 x 2.5
4.1m²
4.1m²
4.1m²
NLA: 50.2m²
NLA: 43.8m²
GROUND FLOOR
4
FUTUREROAD WIDENING
(PAVED)(x
2)
STEPPED 1.8m HIGH COLORBOND FENCE ON PLINTH RETAINING RAKING 0.75m HIGHCOLORBOND FENCE
dp
RESIDENTIALENTRY
COMMERCIAL
ENTRY
RES.# 2
RES.# 3
COMM.# A
RES.# 1
STORE1
STORE2
STORE3
UNISEX
UP TOU1 & U2
VCOMMERCIAL "B"
COMMERCIAL "A"
LAW
LER ST
REET
HILDA STREET
VEHI
CULA
REN
TRY
LETTERS
C
COPYRIGHT PERTH RESIDENTIAL DEVELOPMENTSA.B.N. 65 582 662 731
307 SELBY ST OSBORNE PARK WA 6017PH: 9204 3655 E: [email protected] DATE...............................................
BUILDER.........................................
DATE...............................................
CLIENT............................................
DATE...............................................
CLIENT............................................
JOB No.:
MAP REF.:SHEET No.:
ENG. DETAIL:WIND RATING:COASTAL CAT:
ADDRESS:
CLIENT: DATEDRAFTING LOG
17133
LOT 216 (# 536)CHARLES ST.NORTH PERTH
THI LOAN TRAMNGUYEN
900
3700 4860 11160
3.7m 6.0m
32.79m
20.66m
6.0m
6.19
m
3.7m
13.7m
SCREEN PRIVACY SCREEN
SCR
EEN
BIKE
CONCEPT SCHEME 4
3210
S
S
ENT
CH
AR
LES
STREET
1610054008090
2010 620 2010
6190
2000
4000
LANDSCAPE LANDSCAPE
LAN
DSCA
PE
21/02/18
DRIVEWAY
09/03/18CONCEPT SCHEME 4 revA
PRIVACY
GFL: 9.800
GFL: 9.800
750
500
3740
500
24002002400240020024001000 2002400
gate
9.628
ramp up (1:14)
PAVI
NG: 9
.543
FL: 9.750FL
: 9.75
0
UP TOU3
C
R
R
R
GAT
ES
GAT
ES
GOODS LIFT
F/D
F/D
SCR
EEN
3700
2000 4000
22/05/18CONCEPT SCHEME 4 revB58
00
L'SCAPE
rampup
06/06/18CONCEPT SCHEME 4 revC
ramp down (1:15)
COMM.# B
2690
2300
600
1500
3600
600
DEEP-SOILLANDSCAPE
AREA
PLOT RATIO: 284.9 m² (0.70)SITE AREA: 407.7 m²
12/11/18CONCEPT SCHEME 4 revD 71.2 m²+ 54.6 m²
TOTAL 373.7 m² 5.2 m² 41.4 m² 13.8 m² 84.2 m²
13.5 m²---B 50.2m²NLA
13.5 m²---A 43.8m²NLA
27.0 m²
16.7 m²
4.6 m² 13.5 m²
4.6 m²
PARKINGSTORE
9.3 m²+ 9.2 m²5.2 m²3
12.0 m²-73.6 m²2
10.6 m²-1
UNIT # BALCONYSTAIR
80.3 m²
AREA
4.6 m²
LAN
DSCA
PE
FIRST FLOOR
5
FIRST FLOOR1:100
CAN
OPY
BEL
OW
CANOPY BELOW
3.10 x 3.003.70 x 3.36
5.91 x 4.96
1 2
3.07 x 2.73
3.45 x 3.25
UP
3
DN
3.63 x 3.00
CANOPY BELOW
4.64 x 2.60
CANOPY BELO
WBOX G
UTTER
COPYRIGHT PERTH RESIDENTIAL DEVELOPMENTSA.B.N. 65 582 662 731
307 SELBY ST OSBORNE PARK WA 6017PH: 9204 3655 E: [email protected] DATE...............................................
BUILDER.........................................
DATE...............................................
CLIENT............................................
DATE...............................................
CLIENT............................................
JOB No.:
MAP REF.:SHEET No.:
ENG. DETAIL:WIND RATING:COASTAL CAT:
ADDRESS:
CLIENT: DATEDRAFTING LOG
17133
LOT 216 (# 536)CHARLES ST.NORTH PERTH
THI LOAN TRAMNGUYEN
HILDA STREET
HI-LEVEL
3.40 x 3.4BALCONY
BED 2BED 1
LIVING ROOM
DINING/KITCHEN
SH/RAIL 4xSH
2340 SLIDERS
2340 SLIDERS
2340
BIF
OLD
SREF
(RAKED)
DHO
CLERESTOREY WINDOWS
VV
SHRENS
SHRSHR
OBSC. OBSC.
SH/RAIL
O'H
HP
UBO
DW SS
P'T
80.3 m²
FALL @
3 DEG.
(RAKED)
4xSH
dp
BALUSTR
ADE
4xSH
SH/R
AIL
2340
SLI
DERS
DHO
CLERESTOREY WINDOWS
DINING/KITCHEN
(RAKED)
LIVING ROOM5.91 x 5.08
P'T
BED 2
LIVING4.10 x 4.04HP
UBO
REF
O'H
BALU
STR
ADE
3.95 x 2.69DINING
KITC
HEN
SHR
71.2 m²
APP
MIC
ST
SS
DW
1000
ENT
SHR
V
B/BAR
6280
73.6 m²
CLERESTOREYWINDOWS
(RAKED)BED 1
BALCONY
BALUSTRADE
LAW
LER ST
REET
CH
AR
LES
STREET
DN
LAND
ING
OBS
C.
224070003260600
4860 4640 5580 6030 1350
HI-LEVEL
BED 22.83 x 2.70
2340
SLID
ERS
REF
3000
4000
2340
BIF
OLD
S
VV
SHRENS
SHRSHR
OBSC. OBSC.
WM
WT
LIN
SH/R
AIL
DW SS
HP
UBO
O'H
LIN
WM
WT
LIN
1m DEEPPLANTER
dp
1680
4510
3400
2600
900
13.7m
CONCEPT SCHEME 4
PLOT RATIO: 284.9 m² (0.70)SITE AREA: 407.7 m²
SQUARELINE GUTTER
FALL
@3
DEG
REE
PRIVACY SCREEN
2000
2690
21/02/18
35902380
2300
2050
BALCONY#1
12c WALL
12c
WAL
L
1m DEEPPLANTER
1130 970
09/03/18CONCEPT SCHEME 4 revA
SUN BLADESUN BLADE
SUN
BLA
DE
SUN BLADE
SUN
BLA
DE
1400
(VOID OVER)
BI-FOLDS
GOODS LIFT
O'HO'H
O'H
22/05/18CONCEPT SCHEME 4 revB
PAR
APET
FALL @3 DEG
.
06/06/18CONCEPT SCHEME 4 revC
WM
WT
LIN
WC4xSH
1200
PDPD 3050
12/11/18CONCEPT SCHEME 4 revD
1570
7302720
9000 max
71.2 m²+ 54.6 m²
TOTAL 373.7 m² 5.2 m² 41.4 m² 13.8 m² 84.2 m²
13.5 m²---B 50.2m²NLA
13.5 m²---A 43.8m²NLA
27.0 m²
16.7 m²
4.6 m² 13.5 m²
4.6 m²
PARKINGSTORE
9.3 m²+ 9.2 m²5.2 m²3
12.0 m²-73.6 m²2
10.6 m²-1
UNIT # BALCONYSTAIR
80.3 m²
AREA
4.6 m²
6
UPPER FLOOR
UPPER FLOOR1:100
3.80 x 3.36
2.76 x 2.05
33.70 x 2.48
CONCEPT SCHEME 4
12.2
m
HILDA STREET
CH
AR
LES
STREET
LAW
LER ST
REET
COPYRIGHT PERTH RESIDENTIAL DEVELOPMENTSA.B.N. 65 582 662 731
307 SELBY ST OSBORNE PARK WA 6017PH: 9204 3655 E: [email protected] DATE...............................................
BUILDER.........................................
DATE...............................................
CLIENT............................................
DATE...............................................
CLIENT............................................
JOB No.:
MAP REF.:SHEET No.:
ENG. DETAIL:WIND RATING:COASTAL CAT:
ADDRESS:
CLIENT: DATEDRAFTING LOG
17133
LOT 216 (# 536)CHARLES ST.NORTH PERTH
THI LOAN TRAMNGUYEN
1.6m
14.8m
CLERESTOREY WINDOWS
6.0m3.7m
6.0m
6.2m
13.7m
CLERESTOREY WINDOWS CLERESTOREY WINDOWS
FALL
@3
DEG
REE
FALL
@3
DEG
REE
FALL
@3
DEG
REE
FALL
@15
DEG
REE
BOX GUTTER
BOX GUTTER
PARAPET
PARAPETPARAPET20.66m
32.79m20830
ENSVBED 1
DN
(RAKED)54.6 m²
PWDDRESS
B
SHR
DROP
BALC.#2
SH/ R
AIL
recess
chute
V
OBS
C.
OBSC.
CLERESTOREY
6280
BOX GUTTER
900
HI-LEVEL.
GUTTER & FASCIA
BOX GUTTER
PARAPET
PARAPETFALL @
3 DEGREE
BOX GUTTER
21/02/18
BOX GUTTERPARAPET
2690
2600
PRIVACYSCREEN
PLANTER1m DEEP 23
0037
00
32102480
BALU
STR
ADE
09/03/18CONCEPT SCHEME 4 revA
VOID(RAKED)
CLERESTOREY
(RAKED)
(RAKED)
770145065014501630145014506501450
CONCEPT SCHEME 4 revB 22/05/18
FALL
@3
DEG
REE
FALL
@15
DEG
REE
6280
8690
2930 3550
CONCEPT SCHEME 4 revC 06/06/18
cavitySH/ R
AIL
cavi
tyca
vity
DESK
PLOT RATIO: 284.9 m² (0.70)SITE AREA: 407.7 m²
CONCEPT SCHEME 4 revD 12/11/18
1200
9000
71.2 m²+ 54.6 m²
TOTAL 373.7 m² 5.2 m² 41.4 m² 13.8 m² 84.2 m²
13.5 m²---B 50.2m²NLA
13.5 m²---A 43.8m²NLA
27.0 m²
16.7 m²
4.6 m² 13.5 m²
4.6 m²
PARKINGSTORE
9.3 m²+ 9.2 m²5.2 m²3
12.0 m²-73.6 m²2
10.6 m²-1
UNIT # BALCONYSTAIR
80.3 m²
AREA
4.6 m²26
00
ELEVATIONS 1
NORTH ELEVATION 1:100
WEST ELEVATION 1:100
7
A
GFL: 9.800FOOTPATH: 9.80
2611
COPYRIGHT PERTH RESIDENTIAL DEVELOPMENTSA.B.N. 65 582 662 731
307 SELBY ST OSBORNE PARK WA 6017PH: 9204 3655 E: [email protected] DATE...............................................
BUILDER.........................................
DATE...............................................
CLIENT............................................
DATE...............................................
CLIENT............................................
JOB No.:
MAP REF.:SHEET No.:
ENG. DETAIL:WIND RATING:COASTAL CAT:
ADDRESS:
CLIENT: DATEDRAFTING LOG
17133
LOT 216 (# 536)CHARLES ST.NORTH PERTH
THI LOAN TRAMNGUYEN
CONCEPT SCHEME 4 21/02/18
HIL
DA
ST
LA
WLER S
T
CH
ARLES
ST
2743
257
2611
09/03/18CONCEPT SCHEME 4 revA
SUN BLADESUN BLADE
SUN BLADE SUN BLADE SUN BLADE
FFL: 12.800
(30c+pl)
(30c
+pl)
(32c
)
(35c)
(32c)
(00c)
GFL: 9.800
2611
2743
257
(30c+pl)
(30c
+pl)
(32c
)
(35c)
(32c)
(00c)
(34c)
NGL: 9.62NGL: 9.30
NGL: 9.03NGL: 8.79NGL: 8.52NGL: 8.48
(25c)
(28c) (27c)
(30c
+pl)
(25c
+pl)
172
H
B
C
H
B
B
C
H
D
H
C
C
H
H
A
C
F
C
D
A
A AFF A A
F
F
F
O
AFA
A
A
A F
O O
F F F F F F F
FFFFFFF
AA AA
F A
AFA
F
FFF
F F F
F
F
F
F
F
F
F
F
F
F
S F F
O
F
F
FFFFFF FF FF
LETTERS
22/05/18CONCEPT SCHEME 4 revB
FFL: 12.028F
A
F
PAVING: 9.543
06/06/18CONCEPT SCHEME 4 revC
E
EVOID
VOID
VOID
VOID
ABCDEFG
MATERIALS LEGENDTRIMDEK ROOF @ 15° PITCH
RENDER WITH PAINT FINISH (TYPICAL)
WALL CLADDING WITH PAINT FINISH
FRAMELESS GLASS BALUSTRADE
COLORBOND GUTTERS & DOWNPIPES
H P/COATED ALUMINIUM AWNING WINDOWS
TRIMDEK ROOF @ 3° PITCH
DECORATIVE PRIVACY SCREENI
FEATURE WALL TILING
1028
1028
12/11/18CONCEPT SCHEME 4 revD
2183
ELEVATIONS 2
SOUTH ELEVATION 1:100
8
EAST ELEVATION 1:100
COPYRIGHT PERTH RESIDENTIAL DEVELOPMENTSA.B.N. 65 582 662 731
307 SELBY ST OSBORNE PARK WA 6017PH: 9204 3655 E: [email protected] DATE...............................................
BUILDER.........................................
DATE...............................................
CLIENT............................................
DATE...............................................
CLIENT............................................
JOB No.:
MAP REF.:SHEET No.:
ENG. DETAIL:WIND RATING:COASTAL CAT:
ADDRESS:
CLIENT: DATEDRAFTING LOG
17133
LOT 216 (# 536)CHARLES ST.NORTH PERTH
THI LOAN TRAMNGUYEN
8.21
9.76
257
2611
2742
2611
LANDING: 12.713
BALC: 11.942
1628
CONCEPT SCHEME 4 21/02/18
CH
ARLES
ST
LA
WLER S
T
2400
CONCEPT SCHEME 4 revA 09/03/18
FFL: 12.028
NGL: 9.55ADJ. NGL: 8.98
ADJ. NGL: 8.46NGL: 8.86
ADJ. NGL: 8.20 NGL: 8.31ADJ. NGL: 8.30
GFL: 9.800
FFL: 12.800
FFL: 12.028
FFL: 12.800
(25c
+pl)
(30c
+pl)
172
B
A
D
C
C
D
A
G
I
I
C
D
A AA A A AAA
A A
AF
A A
STEPPED 1.8m HIGHCOLORBOND FENCE
22/05/18CONCEPT SCHEME 4 revB
ADJACENTCARPORTFL: 8.330
HIL
DA
ST
2611
172
FFL: 12.028
NGL: 8.26 NGL: 8.42 NGL: 8.52 NGL: 8.52
BALCONY
BALCONY
PARKING
(30c
+pl)
(25c
+pl)
D
A
G
C
F
H
C
SF
SF
F
A
F
AA
STEPPED 1.8m HIGHCOLORBOND FENCE
3600
772
DRIVEWAY
PAVING: 9.543FOOTPATH: 9.80
06/06/18CONCEPT SCHEME 4 revC
VOID
ABCDEFG
MATERIALS LEGENDTRIMDEK ROOF @ 15° PITCH
RENDER WITH PAINT FINISH (TYPICAL)
WALL CLADDING WITH PAINT FINISH
FRAMELESS GLASS BALUSTRADE
COLORBOND GUTTERS & DOWNPIPES
H P/COATED ALUMINIUM AWNING WINDOWS
TRIMDEK ROOF @ 3° PITCH
DECORATIVE PRIVACY SCREENI
FEATURE WALL TILING
E
SQUARELINE GUTTER
3320
A
UNISEX FL: 9.750
12/11/18CONCEPT SCHEME 4 revD
750
1028
2183
2210
W
S
E
N
MIDDAY - 21st JUNESHADOW DIAGRAM
AREA OF SHADOWCAST OVER BOTH ADJOINING SITES
247 m² of453.0 m²(54.5%)
#81STRATA LOT 2
156.2m²
#534STRATA LOT 1
250.1m²
CP:47 m²
#536LOT 216407.0m²
COPYRIGHT PERTH RESIDENTIAL DEVELOPMENTSA.B.N. 65 582 662 731
307 SELBY ST OSBORNE PARK WA 6017PH: 9204 3655 E: [email protected] DATE...............................................
BUILDER.........................................
DATE...............................................
CLIENT............................................
DATE...............................................
CLIENT............................................
JOB No.:
MAP REF.:SHEET No.:
ENG. DETAIL:WIND RATING:COASTAL CAT:
ADDRESS:
CLIENT: DATEDRAFTING LOG
LOT 216 (# 536)CHARLES ST.NORTH PERTH
THI LOAN TRAMNGUYEN
17133
CONCEPT DESIGN
CONCEPT SCHEME 4 revA
07/10/17
09/03/18
SHADOW
Lawler Street
Charles Street
Hild
a S
treet
CONCEPT SCHEME 4 revB 22/05/18CONCEPT SCHEME 4 revC 19/06/18
TOTAL:247 m²
CONCEPT SCHEME 4 revD 12/11/18
BINS
BINS
34 m²
247 m² TOTAL OVER-SHADOWING -less 34 m² R.O.W OVER-SHADOWING= 213 m² of 453 m² = 47% EFFECTIVE
2