Page 1: Clean Air System Catalogue - AIISHIL Air System... · www. microteknik.net , “AIISHIL" AIR CURTAINS : JCA-01: Invisible air door, keeps interior of a clean room dust-free, stops

 

 

 

 

Page 2: Clean Air System Catalogue - AIISHIL Air System... · www. microteknik.net , “AIISHIL" AIR CURTAINS : JCA-01: Invisible air door, keeps interior of a clean room dust-free, stops

www. microteknik.net , www.microteknik.com

“AIISHIL" AIR CURTAINS :

JCA-01 : Invisible air door, keeps interior of a clean room dust-free,

stops entry of insects, serves as temperature barrier and isolates

heating, cooling & humidity. Fabricated out of mild steel sheet.

Balanced blowers are mounted on strong inside metal frame. Exterior

finished in enamel or hammertone paint. Wall or roof mountings are

provided. Models are available as per door size :

(i) 2 feet. (ii) 2½ feet.(iii) 3 feet. (iv) 4 feet.(v) 6 feet.

“AIISHIL" AIR SHOWERS :JCA-03 : Designed to provide protection from Biological & Particulate

contaminations in high traffic areas and entrances of clean Air

Laboratories or rooms.

Outer made of thick CRC sheet duly powder coated. Dynamically

balanced blowers with minimum vibration and noise level draw the air

and blow it through High Efficiency Hepa filters accurate down to 0.3

microns with efficiency of 99.97% bacteria free area.

Automatic actuating air-shower operation, adjustable time-duration of

air-showers, recirculation of uncontaminated air, adjustable air-

nozzles, clear acrylic door, solid state control system, provision of

fluorescent tube lighting are the main technical features.

(i) Class 10000 (ii) Class 100

“AIISHIL" FUME HOODS :

JCA-05 : Fume exhaust hoods are designed to contain and exhaust

toxic, obnoxious, pungent smelling gasses to protect personnel and

equipment in the laboratories. The "TEKNIK" Fume Hood comprise

with international standard on fume handling systems. A motor driven

dynamically balanced blower with minimal vibration and noise level

creates negetive pressure and sucks contaminated air from work area

and throws the same in high-up atmosphere through ductings.

Fabricated out of thick Duro-board clad from outside in laminated sheet

and inside finished in non-corrosive, chemical resistant Epoxy paint. An

up & down sliding Sash made of Teakwood mounted in thick glass sheet

and workable on weights & pulleys system counter balanced is

provided. Fluorescent lighting is provided in the chamber. A gas tap and

electric power plug also provided in addition to stainless steel wash

basin and suitable water tap. A work-bench with cupboard is provided to

hold the hood at suitable level from ground.

(i) Chamber : 4x2x2'(ii) Chamber : 6x2x2'(iii) Chamber : 8x3x3’

JCA-01

JCA-03

JCA-05

CLEAN AIR SYSTEM

E-mail : infob@aishilgroup,com

Page 3: Clean Air System Catalogue - AIISHIL Air System... · www. microteknik.net , “AIISHIL" AIR CURTAINS : JCA-01: Invisible air door, keeps interior of a clean room dust-free, stops

JCA-011

JCA-021

CLEAN AIR SYSTEM

“AIISHIL" BIO SAFE BIOLOGICAL SAFETY CABINET : CLASS I

JCA-021 : These class I safety cabinet provide protection for the operator and the environment, with inward airflow away from the operator. Air is filtered before release to the atmosphere.

Negative pressure is maintained within the cabinet, which is suitable for work where no product protection is required.

These cabinets are self contained 100% exhaust containment enclosures. Air from the work zone passes through a two-stage, high efficiency filter system before being exhausted to the room/atmosphere. These cabinets may be installed on standard laboratory benches or on optional support stands.

Personel and environment protection is provided by inward flow of room air at the work area and high-efficiency particulate air (HEPA) filtration of exhaust air. The inward airflow sweeps aerosols generated during the work process away from the operator into the filter system. A prefilter protects the HEPA filter from large particles, and the HEPA filter removes particulate contaminates down to sub-micron size from the exhaust air.

Supplied complete as above, with cord and plug, suitable to work on 220 volts single phase, 50 Hz, Ac supply.

Available in following sizes :-Work area 4’x2’x2' 6’x2’x2’

“AIISHIL" BIO SAFE BIOLOGICAL SAFETY CABINET

JCA-011 : ‘Class 100’ Laminar Air Flow BIOSAFE Biological Safety Cabinet complies with the guidelines laid down by U.S. National Institute of Health, and the specifications of British Standard 5726 — Appendix A for class II Biological Safety Cabinets.

In addition to normal feature of Vertical Laminar Flow, It is provided with following unique features :• Re-Circulation of Air - offering highest level of cleanliness.• Sliding Sash - renders unit convertible for use as a conventional vertical laminar

down flow clean air work station.• Filtered Exhaust - protects ambient environment, and avoids build up, air borne

particles.• Supplementary Air Barrier - prevents contamination through make up air.• Glove Ports and Gauntlets - permits working with medium to low-risk organisms,

pathogenic cultures.• Built in U.V. Germicidal light - facilitates sterilization of working area before and

after use.

Supplied complete as above, with cord and plug, suitable to work on 220 volts single phase, 50 Hz, Ac supply.

Available in working sizes :- 4’x2’x2' 6’x2’x2’

E-mail : [email protected]

Page 4: Clean Air System Catalogue - AIISHIL Air System... · www. microteknik.net , “AIISHIL" AIR CURTAINS : JCA-01: Invisible air door, keeps interior of a clean room dust-free, stops

JCA-07

JCA-010

CLEAN AIR SYSTEM

“AIISHIL" LAMINAR AIR FLOW CABINETS :

JCA-07 :-(Horizontal or Vertical flow)

filteration of air through coarse Pre-filters (upto 5 microns) and HEPA filters

(down to 0.3 microns) for filteration of Biological & Particulate contaminants.

A constant uni-directional air flows either Horizontally or Vertically, is drawn

from atmosphere and passed through pre and Hepa filters on to the work

surface. Fabricated out of reinforced pest and weather resistant Duro-board

which is clad in from outside in laminated sheet and inner exposed areas are

finished in Epoxy paint. Table top stainless steel sheet. Side panels are fixed

and made of clear plexiglass. Front door is folding & made of clear

plexiglass.

Prefilters : DOP tested as per Standard BS:2831 with efficiency 90% down

to 5 microns. Made of Washable synthetic material.

Hepa Filters : Made of Microglass fibre with corrugated aluminium foil

separators. DOP tested as per Standard US fed. 209B. Efficiency 99.97%

down to 0.3 microns.

Blower Units : Assembly of AU or equivalent motor workable on 220 V AC

50 Hz single phase, dynamically balanced blowers making the unit least

vibrant with minimum noise level.

Lighting : Fluorescent tube lights.

Sterilization : Germicidal Ultra Violet (UV) tube.

Manometer : Static pressure thick Acrylic block type.

Working Chamber : 02 03 04 06 08

2x2x2' 3x2x2' 4x2x2' 6x2x2' 8x2x2'

Hepa Filters 1 1 1 2 2

Prefilters 1 1 1 2 2

Illumination 1x20W 1x20W 2x40W 2x40W 2x40W

U.V. 1x15W 1x15W 1x30W 1x30W 2x30W

Laminar flow principle involves double

“AIISHIL" PORTABLE TISSUE CULTURE RACK :

JCA-010 : Offering a high quality of tissue culture rack with following

features: Fabricated out of aluminium square pipe OR Angle fitted with

sturdy castor wheel for smooth shifting movement of the unit, Shelves are

made of wooden with aluimnium clad or frosted glass. Each shelves has

been provided with four fluorescent tubes of 4’size. The unit is workable on

220V AC 50Hz single face. Heavy duty electronic chokes have been

mounted seperately on each shelf.

Available Shelves : 4 Shelves, 5 Shelves, 6 Shelves

Photopereodic Timer

E-mail : [email protected]

Page 5: Clean Air System Catalogue - AIISHIL Air System... · www. microteknik.net , “AIISHIL" AIR CURTAINS : JCA-01: Invisible air door, keeps interior of a clean room dust-free, stops

“AIISHIL" GARMENT STORAGE CABINET:

JCA-031 : Self standing providing down flow clean air to clean room Garments.

Recommended in change rooms. Suitable for Pharmaceutical, Hospital and O/T,

Electronic Industry etc. Supplied complete with HEPA & Pre filter, Motor Blower.

Static Pressure Manometer & Built in U.V. Germicidal Light.

Model 03 04

Working Area 3’x2’x5' 4’x2’x5'

Size of HEPA filter 3'x1.5’x6" 4’x1.5’x6"

No. of HEPA filter 1 1 (Supplied with Pre filters)

Optional Accessories :-

• Exhaust Ducting per running feet.

“AIISHIL" STERILE MATERIAL STORAGE CABINET : (VERTICAL

FLOW)JCA-041 : Self standing, down flow clean air cabinet for use in clean rooms for

storage of materials. Suitable for Pharmaceuticals, Hospitals and O/T, Electronic

Industry etc. Supplied complete with HEPA & Pre Filter, Motor Blower, Shelves.

Static Pressure Manometer & Built in U.V. Germicidal Light

Model 03 04

Working Area 3'x2’x5' 4’x2’x5'

Size of HEPA Filter 3’x1.5’x6" 4’x1.5’x6"

No. of HEPA Filter 1 1

No. of Shelves 2 2 (Supplied with Pre filters)

Optional Accessories :-• Exhaust Ducting per running feet.• Extra Shelves

“AIISHIL" TISSUE CULTURE HOODS / ASEPTIC CABINET :

:

JCA - 06 : Elegant equipment with overall dimensions 1220 x 610 x 610 mm having

front horizontal swing door opening of 1050 x 405 mm (frame) fitted with

JCA-031

JCA-041

JCA-06

CLEAN AIR SYSTEM

E-mail : [email protected]

Page 6: Clean Air System Catalogue - AIISHIL Air System... · www. microteknik.net , “AIISHIL" AIR CURTAINS : JCA-01: Invisible air door, keeps interior of a clean room dust-free, stops

“AIISHIL" DEHUMIDIFIERS :

JCA-08 : Designed to remove excess moisture from atmosphere

when manufacturing activities of tablets, capsules and air accuracy is

required. Humidity can be brought down to 30% RH with accuracy of

±3% RH.

Capacity : (i) 1 Ton. (ii) 1.5 Ton.

(iii) 2 Ton. (iv) 3 Ton.

JCA-08

“AIISHIL" INOCULATION HOOD :

JCA-06A : Economical Clean-Air equipment to be used as dust and

bacteria-free environmental enclosure.

Fabricated out of pest and weather resistant Duro-board or mild steel

sheet. Wood construction clad in laminated sheet from outside and

inner exposed parts painted with Epoxy paint. The mild steel model is

enamel painted.

Provided with rectangular, tight coverable opening on one side for

putting the material in the chamber and two coverable round openings

in front for handling of the material. A clear Acrylic fixed window in front

provided for observation.

Complete with fluorescent lighting and germicidal Ultra Violet (UV)

tube.

Chamber Sizes : (i) 40 x 24 x 20" (ii) 27 x 20 x 16”

JCA-06A

CLEAN AIR SYSTEM

E-mail : [email protected]

Page 7: Clean Air System Catalogue - AIISHIL Air System... · www. microteknik.net , “AIISHIL" AIR CURTAINS : JCA-01: Invisible air door, keeps interior of a clean room dust-free, stops

OUR OTHER PRODUCTS RANGE :

VISUAL EQUIPMENTS

MICROTOMY EQUIPMENTS

MICROSCOPY EQUIPMENTS

HEAT & REFRIGERATION

SYSTEM

BLOOD BANKING

GENERAL LABORATORY SYSTEM

PHARMACEUTICAL

PHARMACOLOGY EQUIPMENTS

MEDICAL ANATOMY INSTRUMENTS

ELECTRONIC ANALYTICAL

INSTRUMENTS

INCINERATORS

ENGINEERING COLLEGE EQUIPMENTS