client: across risers in center aisle of … · electrical legend description and/or ... crestron...

7
~ ~ a a 3 a 4 C M ELECTRICAL LEGEND DESCRIPTION AND/OR SPECIFICATION MOUNT ABOVE COUNTER OR SINK AUTOMATIC TEMPERATURE CONTROLS V.F.D. CTR U.O.N. G.F.I. WP UNLESS OTHERWISE NOTED VARIABLE FREQUENCY DRIVE WEATHERPROOF GROUND FAULT INTERRUPTER A.F.G. B.F.G. C A.F.F. A.T.C. ABOVE FINISHED GRADE BELOW FINISHED GRADE ABOVE FINISHED FLOOR CONDUIT 3 SYMBOL 3 3 T J J EXIT LIGHT - CEILING, WALL MOUNTED RESPECTIVELY, WITH ARROWS AS INDICATED. SHADED AREA INDICATES FACE. SINGLE POLE 20 AMP. TOGGLE TYPE SWITCH - 'LEVITON' No. 1221-2I MOUNTED 4'-0" A.F.F. TO TOP. SUB LETTER "a" DENOTES FIXTURE CONTROLLED. THREE WAY 20 AMP. TOGGLE TYPE SWITCH - 'LEVITON' No. 1223-2I MOUNTED 4'-0" A.F.F. TO TOP. SUB LETTER "a" DENOTES FIXTURE CONTROLLED. FOUR WAY 20 AMP. TOGGLE TYPE SWITCH - 'LEVITON' No. 1224-2I MOUNTED 4'-0" A.F.F. TO TOP. SUB LETTER "a" DENOTES FIXTURE CONTROLLED. SINGLE RECEPTACLE 20A. 125V. 'LEVITON' No. 5341-I, MOUNTED 1'-4" A.F.F. TO BOTTOM. 3 = CIRCUIT NUMBER. DUPLEX CONVENIENCE RECEPTACLE 20A. 125V. 'LEVITON' No. 5362-I, MOUNTED 1'-4" A.F.F. TO BOTTOM. '3' = CIRCUIT NUMBER. SAME AS ABOVE EXCEPT GFI TYPE. '3' = CIRCUIT NUMBER. SAME AS DUPLEX OUTLET EXCEPT ISOLATED GROUND TYPE. '3' = CIRCUIT NUMBER. DOUBLE DUPLEX RECEPTACLE TWO 20A. 125V. 'LEVITON' No. 5362-I, MOUNTED 1'-4" A.F.F. TO BOTTOM. '3' = CIRCUIT NUMBER. JUNCTION BOX, CEILING / WALL MOUNTED, ELECTRICAL CONTRACTOR TO MAKE ALL REQUIRED CONNECTIONS TO DESIGNATED EQUIPMENT. REFER TO AV/IT DRAWINGS FOR MOUNTING LOCATIONS AND TYPES. WALL MOUNTED JUNCTION BOX FOR ELECTRIFIED FURNITURE POWER CONNECTION. 3 = CIRCUIT NUMBER. REFER TO AV/IT DRAWINGS FOR MOUNTING LOCATIONS AND TYPES. WALL MOUNTED JUNCTION BOX FOR ELECTRIFIED FURNITURE TELEPHONE / DATA CONNECTION. RUN A 1 1 / 2 " EMPTY CONDUIT WITH DRAG WIRE UP TO HUNG CEILING. TERMINATE WITH BUSHING. LIGHTING AND/OR RECEPTACLE PANEL. MOTOR TRANSFORMER TELEPHONE / DATA OUTLET (SINGLE GANG) MOUNTED 1'-4" A.F.F. TO BOTTOM, UNLESS OTHERWISE NOTED. RUN CONDUIT TO HUNG CEILING SPACE AND TERMINATE IN BUSHING - REFER TO AV/IT, SECURITY AND TECHNOLOGY DRAWINGS FOR BOX SIZE, CONDUIT SIZE, MOUNTING HEIGHTS AND DETAILS. A.I.C. AMPERES INTERRUPTING CAPACITY GFI T RECESSED FLOOR BOX - REFER TO AV/IT DRAWINGS FOR TYPES AND DETAILS F PH. PHASE P 3 SINGLE RECEPTACLE 208 VOLT, THREE PHASE, NEMA L6-30. MOUNTED 1'-4" A.F.F. TO BOTTOM. 3 = CIRCUIT NUMBER. EMERGENCY EM CRESTRON SYSTEM SWITCH - MOUNTED 4'-0" A.F.F. TO TOP. REFER TO AV/IT DRAWINGS FOR DESCRIPTION, CONTROLS AND DETAILS. WALL MOUNTED OCCUPANCY SENSOR TO CONTROL LIGHTING ON/OFF OPERATION. MOUNT 4'-0" A.F.F. TO TOP. SUB LETTER 'a' DENOTES FIXTURE CONTROLLED. CEILING MOUNTED OCCUPANCY SENSOR TO CONTROL NORMAL POWER LIGHTING ON/OFF OPERATION. SUB LETTER 'a' DENOTES FIXTURE CONTROLLED. M LIGHTING FIXTURE DESIGNATIONS. FIXTURES MAY HAVE ALL OR PART OF THESE DESIGNATIONS - TYPICAL FOR ALL FIXTURES, UNLESS OTHERWISE NOTED : 'a' = SWITCH CONTROL 'EM' = FIXTURE ON EMERGENCY CIRCUIT 'A' = FIXTURE TYPE '3' = CIRCUIT NUMBER 1. 2. ELECTRICAL GENERAL NOTES : 3. ALL ELECTRICAL WORK SHALL CONFORM TO THE LATEST EDITIONS OF THE NATIONAL ELECTRICAL CODE AND THE INTERNATIONAL BUILDING CODE. THE ELECTRICAL CONTRACTOR SHALL REVIEW THE ARCHITECTURAL DRAWINGS IN ORDER TO UNDERSTAND THE FULL SCOPE OF WORK AND TO REVIEW THE CONSTRUCTION DETAILS. THE CONTRACTOR MUST HAVE THE H.V.A.C., FIRE PROTECTION AND PLUMBING DRAWINGS FOR LOCATIONS OF EQUIPMENT ONLY POWER FEEDER TO MECHANICAL EQUIPMENT ARE SCHEDULED ON THE ELECTRICAL DRAWINGS. FURNISH AND INSTALL ALL CODE REQUIRED DISCONNECT SWITCHES FOR MECHANICAL EQUIPMENT UNLESS SPECIFIED ON MECHANICAL DRAWINGS TO BE SUPPLIED BY MANUFACTURER. PROVIDE FUSED SWITCHES WHEREVER MANUFACTURER REQUIRES THEM. CONTRACTOR SHALL INCLUDE IN HIS BID (10) EXIT SIGNS, (10) PULL STATIONS, (10) FIRE ALARM SPEAKER/FLASING LIGHT UNITS AND MOUNTING. LOCATIONS SHALL BE DETERMINED IN FIELD. ANY SIGN NOT USED SHALL BE TURNED OVER TO THE OWNER WITH A CREDIT FOR INSTALLATION. 4. 3,4 DOUBLE DUPLEX RECEPTACLE WITH 2 DEDICATED CIRCUITS - MOUNTED 1'-4" A.F.F. TO BOTTOM. '3,4' = CIRCUIT NUMBERS. ADA POWERED DOOR PUSH PLATE - REFER TO SECURITY DRAWINGS FOR MOUNTING DETAILS AND TYPES. P CARD READER - REFER TO SECURITY DRAWINGS FOR MOUNTING DETAILS AND TYPES. C TELEPHONE OUTLET (SINGLE GANG), UNLESS OTHERWISE NOTED. RUN CONDUIT TO HUNG CEILING SPACE AND TERMINATE IN BUSHING - REFER TO AV/IT, SECURITY AND TECHNOLOGY DRAWINGS FOR BOX SIZE, CONDUIT SIZE, MOUNTING HEIGHTS AND DETAILS. WALL MOUNTED PROJECTION SCREEN CONTROL SWITCH WALL MOUNTED ROOM SCHEDULING TOUCH PANEL TP SC LOCATION FOR WALL MOUNTED DISPLAY - REFER TO AV/IT DRAWINGS FOR MOUNTING DETAILS AND SPECIFICATIONS FOR ALL POWER AND COMMUNICATIONS REQUIREMENTS. RECEPTACLE AND DATA DEVICES INDICATED ARE DIAGRAMMATIC AND SHALL BE CONFIRMED PRIOR TO INSTALLATION. T V CONTRACTOR SHALL COORDINATE ALL LOCATIONS, MOUNTING HEIGHTS, CONDUIT SIZING, ROUTING, BACK BOX SIZES, MOUNTING DETAILS AND LOCATIONS, FLOOR BOX AND POKE-THRU REQUIREMENTS, ETC. WITH THE TECHNOLOGY DRAWINGS AND DETAILS, ARCHITECTURAL DRAWINGS AND THE OWNER PRIOR TO INSTALLATION OF ANY DEVICES. 5. CONTRACTOR SHALL PROVIDE A PHASE LOSS SENSOR FOR ALL EMERGENCY LIGHTING IN AREAS INDICATED WITH SWITCHED EMERGENCY LIGHTING. SENSOR SHALL BE PROGRAMMED TO BRING ALL EMERGENCY FIXTURES ON TO FULL BRIGHTNESS IN THE EVENT OF LOSS OF POWER. 6. J AV T,1 SIMILAR TO ABOVE EXCEPT FOR A/V EQUIPMENT. REFER TO AV/IT DRAWINGS FOR EXACT MOUNTING LOCATIONS, SIZES, TYPES AND REQUIRED CONDUIT RUNS. T,1 = POWER CIRCUIT NUMBER WHERE REQUIRED. CONTRACTOR MUST REFER TO TECHNOLOGY DRAWINGS FOR LOCATIONS OF ALL TECHNOLOGY, SECURITY AND A/V RELATED ITEMS. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL POWER WIRING TO ALL REQUIRED LOCATIONS. HE SHALL ALSO BE RESPONSIBLE FOR PROVIDING ALL JUNCTION BOXES, PULL BOXES, BACK BOXES, EMPTY CONDUITS WITH DRAG LINE, CONDUIT STUB UPS, ETC. FOR ALL TECHNOLOGY, SECURITY AND A/V RELATED ITEMS. COORDINATE WITH TECHNOLOGY DRAWINGS FOR ALL REQUIRED SIZES, LOCATIONS, QUANTITIES, TYPES, MOUNTING HEIGHTS, DETAILS, ETC. 7. EXISTING TO REMAIN (E) (R) EXISTING TO BE REMOVED 1. LIGHTING GENERAL NOTES : ELECTRICAL CONTRACTOR SHALL PROVIDE ALL DIMMABLE LIGHTING TO BE INSTALLED WITHIN ANY ROOM WITH AUDIO VISUAL EQUIPMENT WITH BALLASTS CAPABLE OF BEING DIMMED TO 1% UNLESS PROVIDED BY FIXTURE MANUFACTURER. DATA DEVICE FOR CONNECTION TO 'CRESTRON' PANEL - REFER TO TECHNOLOGY DRAWINGS FOR MOUNTING DETAILS AND TYPES. COORDINATE EXACT MOUNTING WITH PANEL LOCATION. C ALL AREAS WITH OCCUPANCY SENSORS WITH SWITCH OVERRIDES SHALL BE PROGRAMMED TO BE MANUAL ON AUTO OFF. 8. ELECTRICAL CONTRACTOR SHALL PROVIDE AN ALTERNATE BID TO PROVIDE 'CRESTRON' DAYLIGHT SENSING IN ALL ROOMS WITH 'CRESTRON' PANEL CONTROLS IN LIEU OF INDIVIDUAL DAYLIGHT HARVESTING FIXTURES. 9. ELECTRICAL CONTRACTOR SHALL PROVIDE AN ALTERNATE BID TO PROVIDE 'CRESTRON' DAYLIGHT SENSING IN ALL ROOMS WITH 'CRESTRON' PANEL CONTROLS IN LIEU OF INDIVIDUAL DAYLIGHT HARVESTING FIXTURES. 2. 3 a,EM,A,3 exit exit CODE MANUFACTURER & PART NUMBER DESCRIPTION NOTES A FOCAL POINT FL44-13LED-L35-277-SO-T- BH/L44-SO-RLMG-CD-WH 4.5” RECESSED ROUND 23W LED DOWNLIGHT WITH CLEAR DIFFUSE REFLECTOR & WHITE FLANGE 3500°K CORRIDORS B FOCAL POINT “LUNA” FLU-24-B-2T8-E-277-G-PS- NO-WH 2X4, 2-T8 RECESSED INDIRECT WITH ELECTRONIC BALLAST & CENTER PERFORATED BASKET C FOCAL POINT “MINI-GRAZER” FGM-BB-1T5HO-1C-277-S- SS-WH-LENGTH? RECESSED WALL SLOT W/60° CUTOFF & WHITE BAFFLE SHIELDING. 1-T5HO IN SECTION. TRIMLESS FLANGE FOR DRYWALL MUD-IN. INTEGRAL ELECTRONIC BALLAST. 12" SLIDING SLEEVES. 12.6"H X 6" W. LOWER LEVEL ENTRY HALL DRYWALL MUST BE LEVEL 5 FINISH D ELLIPTIPAR F306-T255-S-00 277-000 3.75”H x 5.9”W x 93.125”L ASYMMETRIC LINEAR SURFACE MOUNTED UP LIGHT WITH INTEGRAL BALLAST AND 2-T5HO LAMPS LOWER LEVEL ENTRY HALL E AMERLUX SD6-39-T6-E-SD-W- 277-WF 6” SQ RECESSED 39W T6 CMH DOWNLIGHT WITH INTEGRAL ELECTRONIC BALLAST, SEMI- DIFFUSE WIDE FLOOD REFLECTOR AND WHITE FLANGE CAFETERIA F FOCAL POINT “Equation” FEQ-22-B-1-BX40(25W)-S- 277-G-WP RECESSED 2x2 WITH 3 FLAT LENSES, 1-25W BIAX LAMP, INTEGRAL ELECTRONIC BALLAST. FOR GRID CEILING. F-DIM FOCAL POINT “Equation” FEQ-22-B-2-BX40(25W)-D- 277-G-WP-AR LECTURE HALLS, CLASSROOMS & OFFICES F-DAY FOCAL POINT “Equation” FEQ-22-B-2-BX40(25W)-D- 277-G-WP- PY1 OFFICES W/ EXTERIOR FENESTRATION G FOCAL POINT “Equation” FEQ-24-B-2T8-S-277-G-WP RECESSED 2x4 WITH 3 FLAT LENSES, 2, T8 LAMPS, INTEGRAL ELECTRONIC BALLAST. FOR GRID CEILING. G-DAY FOCAL POINT “Equation" FEQ-24-B-2T8-D-277-G-WP- PY1 RECESSED 2x4 WITH 3 FLAT LENSES, 2-T8 LAMPS, INTEGRAL ELECTRONIC DIMMING BALLAST, 0-10 VOLT DAYLIGHT SENSOR. FOR GRID CEILING. H VISA CP4090-10-F50-4-F50-PTD (BRNZ)-DIM-A 45” DIAMETER x 11.5”H SHALLOW BOWL PENDANT WITH MULTI-STEM MOUNT. OVER ALL HEIGHT: 46” 10-F50 BIAX LAMPS UP/ 4-F50 BIAX LAMPS DOWN. INTEGRAL ELECTRONIC DIMMING BALLAST FINISH : BRONZE NO "I" J FOCAL POINT “Verve IV” FV4S-PL-1T8-1C-277-D-C (Length)-TS-Length AIRCRAFT SUSPENDED LINEAR DIRECT/ INDIRECT WITH 1-T8 LAMP, SEMI-SPECULAR PARABOLIC LOUVERS AND INTEGRAL ELECTRONIC DIMMING BALLAST. FINISH: WHITE J1 FOCAL POINT “Verve IV” FV4S-PL-2T8-1C-277-D-C (Length)-TS-Length K ELLIPTIPAR F144-T239-S-22-277-000 72” x 5”W x 2 9/16”D SURFACE MOUNTED T5HO WALL WASH WITH INTEGRAL BAFFLE & HPF BALLAST. CLASSROOM WHITE BOARDS L MERCURY 35E-3-32-OCT-9A.125- ELB-UNI-TG 3T8 2x4 RECESSED TROFFER WITH .125 PRISMATIC LENS & ELECTRONIC BALLAST, TRIPLE GASKETED KITCHEN L1 MERCURY 35E-2-32-OCT-9A.125- ELB-UNI UTILITY AREAS W/CEILINGS M MERCURY M106N-2-32-OCT-A-ELB- UNI SURFACE MOUNTED OR SUSPENDED F32T8 ACRYLIC WRAP AROUND WITH 1-2 LAMP ELECTRONIC BALLAST. UTILITY AREAS W/O CEILINGS N FOCAL POINT “FOCUS IV” FW4-NS-2T8-1C-277-E- RC-SS-HW-LENGTH 10”W x 7.75”H RECESSED PERIMETER WALL WASH WITH EXTRUDED SPLAY WITH 6.8” OPENING. 2, T8 LAMPS BEHIND SHIELD. ELECTRONIC BALLAST. SLIDING END SLEEVE. BATHROOMS P4 ARCHITECTURAL STAR LIGHTING S-8-V-70MH-WHT-SSCL 70 WATT METAL HALIDE SURFACE MOUNTED CYLINDER WITH INTEGRAL ELECTRONIC BALLAST. 14”H x 7.5”DIAMETER SEMI-SPECULAR CLEAR REFLECTOR FINISH: WHITE P5 ARCHITECTURAL STAR LIGHTING AV7MO70UA / AV714SSCL 70 WATT METAL HALIDE RECESSED DOWNLIGHT WITH INTEGRAL ELECTRONIC BALLAST. 7” DIAMETER APERTURE SEMI-SPECULAR CLEAR REFLECTOR R VISA “IMAGE-BOROUGH” CV1906-2F50-277-PTD (BRNZ)-PTD(BRNZ) 48.4” x 7.3” x 4”D ADA COMPLIANT WALL MOUNTED WITH 2-50 WATT COMPACT FLUORESCENT LAMPS & INTEGRAL ELECTRONIC BALLAST FINISH: PAINTED BRONZE ATRIUM, ARCHITECT TO SPECIFY MOUNTING HEIGHT RECESSED 2X2 WITH 3 FLAT LENSES, 2-25W BIAX LAMP, INTEGRAL ELECTRONIC DIMMING BALLAST & AIR RETURN. FOR GRID CEILING. 2X2 RECESSED LUMINAIRE WITH 91.6% EFFICIENCY. 3 FLAT ACRYLIC LENSES & 2-25W BIAX LAMPS. INTEGRAL ELECTRONIC DIMMING BALLAST & INTEGRAL DAY LIGHT SENSOR. FINISH: WHITE AIRCRAFT SUSPENDED LINEAR DIRECT/INDIRECT WITH 2-T8 LAMPS, SEMI-SPECULAR PARABOLIC LOUVERS AND INTEGRAL ELECTRONIC DIMMING BALLAST. FINISH: WHITE 2T8 2x4 RECESSED TROFFER WITH .125 PRISMATIC LENS AND ELECTRONIC BALLAST, TRIPLE GASKETED LIGHT FIXTURE SCHEDULE AA FOCAL POINT FL6D-20LED-L35-LD1-277-RO-T/ L6-RO-DN-CD-WP 6” DIAMETER, RECESSED 2000 LUMEN 3500K LED DOWNLIGHT WITH INTEGRAL 0-10V DIMMABLE DRIVER & WHITE FLANGE BB CUSTOM METALCRAFT “Vulcan” PN-10731-16’-8” DIA. X 60”-F- 277-EO-BRONZE-OA 8” DIAMETER X 60”L OPAL ACRYLIC CYLINDER PENDANT WITH T5HO LAMPS, INTEGRAL ELECTRONIC BALLAST & METAL BANDING AS SPECIFIED BY ARCHITECT. ETCHED OPAL ACRYLIC BOTTOM DIFFUSER. OVER ALL HEIGHT: 16’. FINISH BRONZE LOWER LEVEL VESTIBULE CC1 VISA “VISAGE” CV1660-1FS54-PTD(BRNZ) 47.5”H x 5.25”W x 1”D + 3.5” RECESSED DEPTH WALL ADA COMPLIANT SCONCE WITH ACCENT BARS, 1-T5HO LAMP, INTEGRAL ELECTRONIC BALLAST . FINISH: PAINTED BRONZE LOWER VESTIBULE CC2 VISA “VISAGE” CV1658-1FS24-PTD(BRNZ) 36”H x 5.25”W x 1”D + 3.5” RECESSED DEPTH WALL ADA COMPLIANT SCONCE W/ACCENT BARS, 1- T5HO LAMP, INTEGRAL ELECTRONIC BALLAST. FINISH: PAINTED BRONZE LECTURE HALL DD FOCAL POINT “AVENUE D MOD-FAVDS-FL-2-T5HO -3C- 277-D(Down only)-C24”- MR16-FM-TS-Length 24” AIRCRAFT CABLE SUSPENDED LINEAR LUMINAIRE WITH 1-T5HO LAMP WITH FLUSH SATIN LENS DOWN LIGHT AND 1-T5HO UP LIGHT. INTEGRAL DIMMING ELECTRONIC BALLAST FOR T5HO (DOWN) LAMPS ONLY. SEPARATE CIRCUITS 4.5”H X 3.2”W. MR16 FLUSH MOUNTS WITH 25° VERTICAL ADJUSTMENT & INTEGRAL TRANSFORMER ALTERNATING WITH T5HO LAMPS. 1 MR16 BETWEEN EACH 4' T5HO. SEPARATE DIMMABLE CIRCUIT LECTURE HALL FF ELLIPTIPAR F204-X2-55-t-02-277-000 ATRIUM STAIRWELL WALL. MOUNT 3’ FROM WALL and 4’ ON CENTER SEMI-RECESSED ASYMMETRIC WALL WASH W/2-55W BIAX LAMPS IN SECTION, INTEGRAL ELECTRONIC BALLAST & PARABOLIC CROSS BAFFLE. 4”F x 9 5/8”W x 27 5/8”L GG ELLIPTIPAR F305-T255-S-00-277-000 2.63”H x 5.63”W x 93.125”L ASYMMETRIC LINEAR SURFACE MOUNTED UP LIGHT WITH INTEGRAL BALLAST AND 2-T5HO LAMPS ATRIUM COVE LIGHT HH FOCAL POINT FL6W-20LED-L35-LD1-277-RO-T/ L6-RO-WW-CD-WP 6” DIAMETER, RECESSED 2000 LUMEN 3500K LED WALL WASH WITH INTEGRAL 0-10V DIMMABLE DRIVER AND WHITE FLANGE JJ ARCHITECTURAL STAR LIGHTINGAH6E226UV /AH610Semi-specular RECESSED 6” DIAMETER DOWNLIGHT WITH 2-26W COMPACT FLUORESCENT LAMPS, SEMI-SPECULAR OPEN REFLECTOR AND INTEGRAL ELECTRONIC BALLAST R1 VISA “IMAGE-BOROUGH” CV1902-1F50-277-PTD (BRNZ)-PTD(BRNZ) 24.9” x 7.3” x 4”D ADA COMPLIANT WALL MOUNTED WITH 1-50 WATT COMPACT FLUORESCENT LAMPS & INTEGRAL ELECTRONIC BALLAST, FINISH: PAINTED BRONZE ATRIUM ENTRANCE, ARCHITECT TO SPECIFY MOUNTING HEIGHT S VISA "CYLINDER" CP4350-4F40-277-1T250PAR38- PTD(BRNZ)-DIM-A -277-OAH:14'0" 11.25" DIAMETER x 30"H ACRYLIC LENS CYLINDER WITH 4-39 WATT COMPACT FLUORESCENT LAMPS AND INTEGRAL ADVANCE MARK-10 DIMMING BALLAST FINISH:BRONZE OAH:14'0" T SE'LUX M1R2S-2T5-OD-TS- LENGTH-277 4” x 4” RECESSED EXTRUDED ALUMINUM LINEAR LUMINAIRE WITH EXTRA DIFFUSE LENS. 2-T5 STAGGERED LAMPS IN SECTION. 1” ¼-20 STUDS FOR MOUNTING INTEGRAL ELECTRONIC BALLAST MOUNT VERTICALLY IN ELEVATOR LOBBY WALLS U SE'LUX M10-2T5-MP- F-LENGTH- SV-277-DM-MSO CONFERENCE ROOMS ALTERNATE MR16’s & T5 SECTIONS BASED ON TABLE LENGTH UU VISA “SOUTH BAY” TF1002-1F38-PTD (BLACK)-PTD(BLACK)- WLS-CORD & PLUG CORD & PLUG TABLE LAMP. 29”H WITH WHITE LINEN SHADE 22” DIA. x 8”H. 1-38W FLUORESCENT LAMP & INTEGRAL 120 VOLT ELECTRONIC BALLAST. FINISH: BLACK ATRIUM TABLES 4” x 4” SURFACE MOUNTED LINEAR LUMINAIRE WITH 2-T5 LAMPS IN SECTION BEHIND SILKY SPECULAR PARABOLIC BAFFLE WITH 6"L INTEGRAL ADJUSTABLE MR16 ACCENTS. SEPARATE DIMMABLE CIRCUITS FOR T5 AND MR16 COMPONENTS. INTEGRAL DIMMING BALLAST FOR T5'S - FINISH: SILVER L2 MERCURY 35E-2-32-OCT-SPW-3/4- ELBD-UNI CONTROL ROOM 121 2T8 2x4 RECESSED TROFFER WITH ¾" PARAWEDGE LOUVER AND ELECTRONIC DIMMING BALLAST MM PP TIVOLI “LED FASTUBE” FTL-03-04-WW-Length-12 FTL-TC-2030-JT PARALLEL WIRED 1 / 4 " x 5 / 16 ” SEMI-RIGID CLEAR TUBE WITH 0.24W WARM WHITE LED’S, 4” ON CENTER. 12VOLT - 3 / 8 ” x 1 / 2 ” WHITE PVC CHANNEL FOR ABOVE - DIMMABLE 12V DC TRANSFORMERS FOR ABOVE - WATTAGE TBD ACROSS RISERS IN CENTER AISLE OF LARGE LECTURE HALL, FIRST FLOOR RR ARCHITECTURAL STAR LIGHTING AH6E226UV /AH630SPCL WET LOCATION RECESSED 6” DIAMETER DOWN LIGHT WITH 2-26 WATT COMPACT FLUORESCENT LAMPS, SPECULAR CLEAR SPLAY LENS WITH PRISMATIC LENS & INTEGRAL ELECTRONIC BALLAST SS ARCHITECTURAL STAR LIGHTING ADV600 / ADV610Semi-specular 6” DIAMETER RECESSED 100 WATT PAR30 ADJUSTABLE ACCENT WITH CLEAR SEMI-SPECULAR REFLECTOR. 30DEG. VERTICAL ADJUSTMENT A1 FOCAL POINT FL44-13LED-L35-277-SO-T- BH /L44-SO-DN-CD-WH 4.5” RECESSED SQUARE 23W LED DOWNLIGHT WITH CLEAR DIFFUSE REFLECTOR, REGRESSED LENS & WHITE FLANGE 3500°K R2 VISA “IMAGE-BOROUGH” OW1294-2F39-277-PTD (BRNZ)-PTD(BRNZ) 36” x 7.3” x 4”D ADA COMPLIANT WALL MOUNTED WITH 2-39 WATT COMPACT FLUORESCENT LAMPS & INTEGRAL ELECTRONIC BALLAST - FINISH: PAINTED BRONZE - WET LOCATION KK1 CUSTOM METALCRAFT “ANDROMEDA” PN-10312-36”-3CF26DT-277- DIM-FAB?-BRONZE-OAH? 36”L x 12”H FABRIC COVERED ELLIPTICAL PENDANT WITH 3-26W COMPACT FLUORESCENT LAMPS AND INTEGRAL ELECTRONIC DIMMING BALLAST. CRUCIFORM BRACE. FINISH BRONZE PRESIDENT'S OFFICE TT VISA “MIDLAND CRAFTS” CP4810-2QF26-277-PTD (BRNZ)-PTD(BRNZ) SURFACE MOUNTED 2-26 WATT COMPACT FLUORESCENT LAMP DECORATIVE LUMINAIRE. INTEGRAL ELECTRONIC BALLAST 14 1 / 8 ” SQUARE x 5 7 / 8 ”H. FINISH PAINTED BRONZE F-DAY-AR FOCAL POINT “Equation” FEQ-22-B-2-BX40(25W)-D- 277-G-WP-AR-PY1 RECESSED 2x2 WITH 3 FLAT LENSES, 2-25W BIAX LAMP, INTEGRAL ELECTRONIC DIMMING BALLAST, 0-10 VOLT DAYLIGHT SENSOR. FOR GRID CEILING. F-DIM-AR F-AR FOCAL POINT “Equation” FEQ-22-B-1-BX40(25W)- S-277-G-WP-AR RECESSED 2x2 WITH 3 FLAT LENSES, 1-25W BIAX LAMP, INTEGRAL ELECTRONIC BALLAST & AIR RETURN. FOR GRID CEILING. LAMPS INCLUDED 2-F32T8/ADV835 36,000 HRS. 3100 LUMEN ONLY 1-F45T5/841/HO 2-F45T5/835/HO 1-CDM35/T6/839 2-PL-L40W/ 835/XEW/4P/ IS25W 2-F32T8/ ADV835 2-F32T8/ ADV835 14-FT50W/ 2G11/835 1-F32T8/ ADV835 2-F32T8/ ADV835 2-F39T5/385/HO 3-F32T8/ ADV835 2-F32T8/ ADV835 2-F32T8/835 2-F32T8/ ADV835 1-MHC70/ U/MP/3K 1-MHC70/ U/MP/3K 2-FT50W/ 2G11/RS/835 1-FT50W/ 2G11/RS/835 4-FT40W/ 2G11/835 1-60PAR38/ IRC/HAL/FL40° 2-F28T5/835 2-F28T5/835 1-50MR16/FL40 (EXN) 12 VOLT Z W FOCAL POINT “TWELVE” FTWS-PB-1T5HO-1C-277-D-J- 12-EC-TS-LENGTH EXIT 48"x9"Wx1.43"H PARALLEL BLADE BAFFLE WITH CU FILTER, T5HO LAMP, SINGLE CIRCUIT, WITH ELECTRINIC DIMMING BALLAST AND SILVER FINISH LUMINAIRE TSL9-4-112WHP-3500K-2B-277- OP-BLACK 9.40”W x 4”D x 48.45”L ADA COMPLIANT VANDAL RESISTANT POLYCARBONATE OPAL LENS WITH ONE ROW LED CONSTANTLY ON AND ONE ROW SENSORED, BUILT IN SENSOR,112W, 3500K LED'S. FINISH: BLACK STAIRWELLS ARCHITECT TO SPECIFY MOUNTING HEIGHT AFF Z1 LUMINAIRE VPF84-232-ELECT-277- OP-BLACK-WET 8.75”W x 4”D x 49.68”L VANDAL RESISTANT WET LOCATION POLYCARBONATE OPAL LENS WITH 56W 3500K LED'S. FINISH: BLACK PARKING AREAS XX PRISMA "OPTALUM 36" 093740 / 2793 / 299 14.2" DIAMETER x 11"H FROSTED REFRACTOR PENDANT WITH FROSTED DIFFUSER DISC & 75" FIELD CUT STRAIGHT FEED WIRE. 1-42 WATT COMPACT FLUORESCENT LAMP & INTEGRAL ELECTRONIC BALLAST OVERALL HEIGHT: 88.5". METAL FINISH: CHROME YY PRISMA "OPTALUM 19" 073730 / 2781 / MAT GLASS LENS 1-F45T5/835/HO EVELITE TEX-R-#Faces LED INCLUDED CORRIDORS, OFFICES NO "O" NN LUCIFER DL2RXM / DH-NIC-XF-HAL-50- 277 1.88” DIAMETER RECESSED MR16 ADJUSTABLE ACCENT WITH 45° VERTICAL ADJUSTMENT INTEGRAL ELECTRONIC TRANSFORMER ROOM 202L DEAN’S OFFICE K1 ELLIPTIPAR F144-T139-S-22-277-000 36” x 5”W x 2 9/16”D SURFACE MOUNTED T5HO WALL WASH WITH INTEGRAL BAFFLE & HPF BALLAST. CLASSROOM WHITE BOARDS 1-F39T5/385/HO 2-F32T8/ ADV835 2-FT39W/ 2G11/RS/835 TO BE DETERMINED 1-F45T5/835/HO 1-F39T5/835/HO 2-F45T5/835/HO (DOWN) 1-50MR16/ NFL/25° (EXZ 12 VOLT) 2-FT55W/ 2G11/835 2-F45T5/835/HO INCLUDED 2-CFQ26W/ G24q/835 3-CFQ26W/ G24q/835 1-50MR16/ VWFL55° (FNV) 0.24W T 1 3/4WWW (INCLUDED) 2-CFQ26W/ G24q/835 1-60PAR30/ IRC/HAL/WFL40° 2-CFQ26W/ G24q/835 1-F38/2D/835/4P WW DESIGN PLAN "LINEAR LED" AV1-L-LED-CZ-1-FINISH?-0- 120V-C 27" x 3.5"W x 3"H SURFACE MOUNTED WET LOCATION ASYMMETRIC WALL GRAZER WITH NARROW BEAM OPTICS. 12-3 WATT 35K LED'S & INTEGRAL 120 VOLT DRIVER. CLEAR POLYCARBONATE LENS & 3" DEEP BRACKET INCLUDED ARCHITECT TO SPECIFY MOUNTING HEIGHT ABOVE GRADE AIM DOWNWARD. 1-CFTR42W/ GX24q/835 7.5" DIAMETER x 7"H FROSTED REFRACTOR PENDANT WITH FROSTED DIFFUSER DISC & 75" FIELD CUT STRAIGHT FEED WIRE. 1-26 WATT COMPACT FLUORESCENT LAMP & INTEGRAL ELECTRONIC BALLAST. OVERALL HEIGHT: 88.5". METAL FINISH: CHROME 1-CFQ26W/ G24q/835 ZZ TIVOLI "COVELUME 120" CVL1-20-U-32-120V- LENGTH? 5.5W 1.5"H x 1 7/16" W x 4 1/4"L MODULE COVE LIGHT, WITH 4, 3200K LED CLUSTERS 2.5" ON CENTER. ADJUSTABLE DIRECTIONAL MOUNTING 120V EXECUTIVE CONFERENCE ROOMS MAX. RUN LENGTH = 200' SET MTG AT 30° INCLUDED AAA Cyclone CL61T4-FLPC- GR3-70MH-277-EA1-DFP- F1AP-TE-W1-Finish UNIVERSAL SURFACE MOUNTED RED LETTER ON CLEAR BACKGROUND LED EXIT SIGN 70 WATT METAL HALIDE WALL MOUNTED DECORATIVE HEXAGONAL LANTERN WITH FLAT CLEAR TEMPERED GLASS LENSES, INTEGRAL ELECTRONIC BALLAST. TYPE 3 OPTICS. FINIAL & DECORATIVE TEETH. 36”H x 20 ¾" DIAMETER CODE MANUFACTURER & PART NUMBER DESCRIPTION NOTES LIGHT FIXTURE SCHEDULE LAMPS BBB LSI INDUSTRIES “Greenbriar” GBWS-3-26-CFL2-F-277- BRZ-CWBB 2-26 WATT COMPACT FLUORESCENT WET LOCATION WALL MOUNTED WITH TYPE III OPTICS, INTEGRAL ELECTRONIC BALLAST. FINISH: BRONZE. DARK SKY COMPLIANT 2-CFTR26W/ Gx24q/835 CCC H.E.WILLIAMS SWL-50PSMH-277-FTG- DBR 50 WATT METAL HALIDE RECESSED STEP LIGHT WITH TEMPERED GLASS LENS & INTEGRAL ELECTRONIC BALLAST, FINISH: BRONZE 14 3/8”L x 7 3/8”H x 6”D 4th Floor Terrace LECTURE HALLS, CLASSROOMS & OFFICES CORRIDORS, OFFICES 2-PL-L40W/ 835/XEW/4P/ IS25W 2-PL-L40W/ 835/XEW/4P/ IS25W 1-PL-L40W/ 835/XEW/4P/ IS25W 1-PL-L40W/ 835/XEW/4P/ IS25W 2-PL-L40W/ 835/XEW/4P/ IS25W FOCAL POINT “Equation” FEQ-22-B-2-BX40(25W)-D- 277-G-WP LECTURE HALLS, CLASSROOMS & OFFICES RECESSED 2x2 WITH 3 FLAT LENSES, 2-25W BIAX LAMP, INTEGRAL ELECTRONIC DIMMING BALLAST. FOR GRID CEILING. G-AR FOCAL POINT “Equation” FEQ-24-B-2T8-S-277-G-WP-AR RECESSED 2x4 WITH 3 FLAT LENSES, 2, T8 LAMPS, INTEGRAL ELECTRONIC BALLAST AND AIR RETURN. FOR GRID CEILING. 2-F32T8/ ADV835 LECTURE HALLS, CLASSROOMS & OFFICES 1-MHC70/ U/M/3K FOCAL POINT FL6D-20LED-L35-LD1-277-RO-T/ L6-RO-DN-CD-WP 6” DIAMETER, RECESSED 2000 LUMEN 3500K LED DOWNLIGHT W/INTEGRAL 0-10V DIMMABLE DRIVER AND WHITE FLANGE INCLUDED INCLUDED INCLUDED FFF FOCAL POINT “Vault” FVAL-22-CN-LL2-L35-LD1- 277-G-AR-WH RECESSED 2x2 LED FIXTURE WITH AIR RETURN, AND WHITE FINISH FOR STANDARD GRID M.R.O. SUITE LED INCLUDED J4 FOCAL POINT “Verve IV” 4'-0" LONG SECTION INCORPORATED WITH TYPE 'J' OR 'J1' WITH 3 LAMPS. TWO OUTER LAMPS TO BE WIRED VIA ELECTRONIC DIMMING BALLAST AND CENTER LAMP TO HAVE ELECTRONIC NO-DIMMING BALLAST. CENTER LAMP TO BE WIRED TO EMERGENCY CIRCUIT. 3-F32T8/ ADV835 LED INCLUDED LED INCLUDED R2a VISA “IMAGE-BOROUGH” CV1904-2F39-277-PTD (BRNZ)-PTD(BRNZ) 36” x 7.3” x 4”D ADA COMPLIANT WALL MOUNTED WITH 2-39 WATT COMPACT FLUORESCENT LAMPS & INTEGRAL ELECTRONIC BALLAST - FINISH: PAINTED BRONZE - WET LOCATION 2-FT39W/ 2G11/RS/835 TMG Engineering Inc. TMG JOB NUMBER Fax: 732-738-9672 1090 King Georges Post Rd. Suite No. 903 Edison, New Jersey 08837 Phone: 732-738-9670 New Jersey Certificate of Authorization Number 24GA28081900 Consulting Mechanical and Electrical Engineers ISSUE DATE: SHEET NUMBER: SHEET TITLE: Copyright (c) by Environetics, Inc. All Rights Reserved. CHECKED BY: DRAWN BY: PROJECT NUMBER: DESIGN DELIVERABLE: REV DATE DESCRIPTION CLIENT: PROJECT TEAM: SEAL: Structural Engineer: Environetics Design 1617 JFK BLVD., Suite 1600 Philadelphia, PA 19103 Montclair, New Jersey CLIENT: Architect: Environetics Group Architects 180 Sylvan Ave. Englewood Cliffs, NJ 07632 MEP Engineer: TMG Engineering Inc. 1090 King Georges Post Road Suite 903 Edison, NJ 08837 Civil Engineer: Langan Engineering & Environmental Services 619 River Drive Center 1 Elmwood Park, NJ 07407-1338 AV / IT / Security / Accoustical Consultant: The Sextant Group Inc. 730 River Avenue Pittsburgh, PA Suite 600 15212 MONTCLAIR STATE UNIVERSITY SCHOOL OF BUSINESS MONTCLAIR, NEW JERSEY ADDENDUM NO. 2 06/17/13 6/14/2013 3:29:13 PM E-1 ELECTRICAL - LEGEND, SCHEDULES, NOTES AND DETAILS Montclair State University P.B. Ken S. 10-115 Montclair State University 10-115 FRANK S. RADOSIN N.J.P.E. 33923

Upload: vuquynh

Post on 20-Aug-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

~ ~

a

a3

a4

C

M

ELECTRICAL LEGENDDESCRIPTION AND/OR SPECIFICATION

MOUNT ABOVE COUNTER OR SINK

AUTOMATIC TEMPERATURE CONTROLS

V.F.D.

CTR

U.O.N.

G.F.I.

WP

UNLESS OTHERWISE NOTED

VARIABLE FREQUENCY DRIVE

WEATHERPROOF

GROUND FAULT INTERRUPTER

A.F.G.

B.F.G.

C

A.F.F.

A.T.C.

ABOVE FINISHED GRADE

BELOW FINISHED GRADE

ABOVE FINISHED FLOOR

CONDUIT

3

SYMBOL

3

3

T

J J

EXIT LIGHT - CEILING, WALL MOUNTED RESPECTIVELY, WITH ARROWS AS INDICATED. SHADEDAREA INDICATES FACE.

SINGLE POLE 20 AMP. TOGGLE TYPE SWITCH - 'LEVITON' No. 1221-2I MOUNTED 4'-0" A.F.F. TOTOP. SUB LETTER "a" DENOTES FIXTURE CONTROLLED.

THREE WAY 20 AMP. TOGGLE TYPE SWITCH - 'LEVITON' No. 1223-2I MOUNTED 4'-0" A.F.F. TOTOP. SUB LETTER "a" DENOTES FIXTURE CONTROLLED.

FOUR WAY 20 AMP. TOGGLE TYPE SWITCH - 'LEVITON' No. 1224-2I MOUNTED 4'-0" A.F.F. TOTOP. SUB LETTER "a" DENOTES FIXTURE CONTROLLED.

SINGLE RECEPTACLE 20A. 125V. 'LEVITON' No. 5341-I, MOUNTED 1'-4" A.F.F. TO BOTTOM. 3 =CIRCUIT NUMBER.

DUPLEX CONVENIENCE RECEPTACLE 20A. 125V. 'LEVITON' No. 5362-I, MOUNTED 1'-4" A.F.F. TOBOTTOM. '3' = CIRCUIT NUMBER.

SAME AS ABOVE EXCEPT GFI TYPE. '3' = CIRCUIT NUMBER.

SAME AS DUPLEX OUTLET EXCEPT ISOLATED GROUND TYPE. '3' = CIRCUIT NUMBER.

DOUBLE DUPLEX RECEPTACLE TWO 20A. 125V. 'LEVITON' No. 5362-I, MOUNTED 1'-4" A.F.F. TOBOTTOM. '3' = CIRCUIT NUMBER.

JUNCTION BOX, CEILING / WALL MOUNTED, ELECTRICAL CONTRACTOR TO MAKE ALLREQUIRED CONNECTIONS TO DESIGNATED EQUIPMENT. REFER TO AV/IT DRAWINGS FORMOUNTING LOCATIONS AND TYPES.

WALL MOUNTED JUNCTION BOX FOR ELECTRIFIED FURNITURE POWER CONNECTION. 3 =CIRCUIT NUMBER. REFER TO AV/IT DRAWINGS FOR MOUNTING LOCATIONS AND TYPES.

WALL MOUNTED JUNCTION BOX FOR ELECTRIFIED FURNITURE TELEPHONE / DATACONNECTION. RUN A 1 1/2" EMPTY CONDUIT WITH DRAG WIRE UP TO HUNG CEILING.TERMINATE WITH BUSHING.

LIGHTING AND/OR RECEPTACLE PANEL.

MOTOR

TRANSFORMER

TELEPHONE / DATA OUTLET (SINGLE GANG) MOUNTED 1'-4" A.F.F. TO BOTTOM, UNLESSOTHERWISE NOTED. RUN CONDUIT TO HUNG CEILING SPACE AND TERMINATE IN BUSHING -REFER TO AV/IT, SECURITY AND TECHNOLOGY DRAWINGS FOR BOX SIZE, CONDUIT SIZE,MOUNTING HEIGHTS AND DETAILS.

A.I.C. AMPERES INTERRUPTING CAPACITY

GFI

T

RECESSED FLOOR BOX - REFER TO AV/IT DRAWINGS FOR TYPES AND DETAILS

F

PH. PHASE

P

3SINGLE RECEPTACLE 208 VOLT, THREE PHASE, NEMA L6-30. MOUNTED 1'-4" A.F.F. TOBOTTOM. 3 = CIRCUIT NUMBER.

EMERGENCYEM

CRESTRON SYSTEM SWITCH - MOUNTED 4'-0" A.F.F. TO TOP. REFER TO AV/IT DRAWINGS FORDESCRIPTION, CONTROLS AND DETAILS.

WALL MOUNTED OCCUPANCY SENSOR TO CONTROL LIGHTING ON/OFF OPERATION. MOUNT4'-0" A.F.F. TO TOP. SUB LETTER 'a' DENOTES FIXTURE CONTROLLED.

CEILING MOUNTED OCCUPANCY SENSOR TO CONTROL NORMAL POWER LIGHTING ON/OFFOPERATION. SUB LETTER 'a' DENOTES FIXTURE CONTROLLED.M

LIGHTING FIXTURE DESIGNATIONS. FIXTURES MAY HAVE ALL OR PART OF THESEDESIGNATIONS - TYPICAL FOR ALL FIXTURES, UNLESS OTHERWISE NOTED : 'a' = SWITCH CONTROL 'EM' = FIXTURE ON EMERGENCY CIRCUIT 'A' = FIXTURE TYPE '3' = CIRCUIT NUMBER

1.

2.

ELECTRICAL GENERAL NOTES :

3.

ALL ELECTRICAL WORK SHALL CONFORM TO THE LATEST EDITIONS OF THE NATIONALELECTRICAL CODE AND THE INTERNATIONAL BUILDING CODE.

THE ELECTRICAL CONTRACTOR SHALL REVIEW THE ARCHITECTURAL DRAWINGS IN ORDER TOUNDERSTAND THE FULL SCOPE OF WORK AND TO REVIEW THE CONSTRUCTION DETAILS.

THE CONTRACTOR MUST HAVE THE H.V.A.C., FIRE PROTECTION AND PLUMBING DRAWINGS FORLOCATIONS OF EQUIPMENT ONLY POWER FEEDER TO MECHANICAL EQUIPMENT ARE SCHEDULEDON THE ELECTRICAL DRAWINGS. FURNISH AND INSTALL ALL CODE REQUIRED DISCONNECTSWITCHES FOR MECHANICAL EQUIPMENT UNLESS SPECIFIED ON MECHANICAL DRAWINGS TO BESUPPLIED BY MANUFACTURER. PROVIDE FUSED SWITCHES WHEREVER MANUFACTURERREQUIRES THEM.

CONTRACTOR SHALL INCLUDE IN HIS BID (10) EXIT SIGNS, (10) PULL STATIONS, (10) FIRE ALARMSPEAKER/FLASING LIGHT UNITS AND MOUNTING. LOCATIONS SHALL BE DETERMINED IN FIELD.ANY SIGN NOT USED SHALL BE TURNED OVER TO THE OWNER WITH A CREDIT FOR INSTALLATION.

4.

3,4DOUBLE DUPLEX RECEPTACLE WITH 2 DEDICATED CIRCUITS - MOUNTED 1'-4" A.F.F. TOBOTTOM. '3,4' = CIRCUIT NUMBERS.

ADA POWERED DOOR PUSH PLATE - REFER TO SECURITY DRAWINGS FOR MOUNTINGDETAILS AND TYPES.P

CARD READER - REFER TO SECURITY DRAWINGS FOR MOUNTING DETAILS AND TYPES.C

TELEPHONE OUTLET (SINGLE GANG), UNLESS OTHERWISE NOTED. RUN CONDUIT TO HUNGCEILING SPACE AND TERMINATE IN BUSHING - REFER TO AV/IT, SECURITY ANDTECHNOLOGY DRAWINGS FOR BOX SIZE, CONDUIT SIZE, MOUNTING HEIGHTS AND DETAILS.

WALL MOUNTED PROJECTION SCREEN CONTROL SWITCH

WALL MOUNTED ROOM SCHEDULING TOUCH PANELTP

SC

LOCATION FOR WALL MOUNTED DISPLAY - REFER TO AV/IT DRAWINGS FOR MOUNTINGDETAILS AND SPECIFICATIONS FOR ALL POWER AND COMMUNICATIONS REQUIREMENTS.RECEPTACLE AND DATA DEVICES INDICATED ARE DIAGRAMMATIC AND SHALL BE CONFIRMEDPRIOR TO INSTALLATION.

T V

CONTRACTOR SHALL COORDINATE ALL LOCATIONS, MOUNTING HEIGHTS, CONDUIT SIZING,ROUTING, BACK BOX SIZES, MOUNTING DETAILS AND LOCATIONS, FLOOR BOX AND POKE-THRUREQUIREMENTS, ETC. WITH THE TECHNOLOGY DRAWINGS AND DETAILS, ARCHITECTURALDRAWINGS AND THE OWNER PRIOR TO INSTALLATION OF ANY DEVICES.

5.

CONTRACTOR SHALL PROVIDE A PHASE LOSS SENSOR FOR ALL EMERGENCY LIGHTING IN AREASINDICATED WITH SWITCHED EMERGENCY LIGHTING. SENSOR SHALL BE PROGRAMMED TO BRINGALL EMERGENCY FIXTURES ON TO FULL BRIGHTNESS IN THE EVENT OF LOSS OF POWER.

6.

JAV

T,1 SIMILAR TO ABOVE EXCEPT FOR A/V EQUIPMENT. REFER TO AV/IT DRAWINGS FOR EXACTMOUNTING LOCATIONS, SIZES, TYPES AND REQUIRED CONDUIT RUNS. T,1 = POWER CIRCUITNUMBER WHERE REQUIRED.

CONTRACTOR MUST REFER TO TECHNOLOGY DRAWINGS FOR LOCATIONS OF ALL TECHNOLOGY,SECURITY AND A/V RELATED ITEMS. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALLPOWER WIRING TO ALL REQUIRED LOCATIONS. HE SHALL ALSO BE RESPONSIBLE FORPROVIDING ALL JUNCTION BOXES, PULL BOXES, BACK BOXES, EMPTY CONDUITS WITH DRAG LINE,CONDUIT STUB UPS, ETC. FOR ALL TECHNOLOGY, SECURITY AND A/V RELATED ITEMS.COORDINATE WITH TECHNOLOGY DRAWINGS FOR ALL REQUIRED SIZES, LOCATIONS, QUANTITIES,TYPES, MOUNTING HEIGHTS, DETAILS, ETC.

7.

EXISTING TO REMAIN(E)

(R) EXISTING TO BE REMOVED

1.

LIGHTING GENERAL NOTES :

ELECTRICAL CONTRACTOR SHALL PROVIDE ALL DIMMABLE LIGHTING TO BE INSTALLED WITHINANY ROOM WITH AUDIO VISUAL EQUIPMENT WITH BALLASTS CAPABLE OF BEING DIMMED TO 1%UNLESS PROVIDED BY FIXTURE MANUFACTURER.

DATA DEVICE FOR CONNECTION TO 'CRESTRON' PANEL - REFER TO TECHNOLOGYDRAWINGS FOR MOUNTING DETAILS AND TYPES. COORDINATE EXACT MOUNTING WITHPANEL LOCATION.

C

ALL AREAS WITH OCCUPANCY SENSORS WITH SWITCH OVERRIDES SHALL BE PROGRAMMED TOBE MANUAL ON AUTO OFF.

8.

ELECTRICAL CONTRACTOR SHALL PROVIDE AN ALTERNATE BID TO PROVIDE 'CRESTRON'DAYLIGHT SENSING IN ALL ROOMS WITH 'CRESTRON' PANEL CONTROLS IN LIEU OF INDIVIDUALDAYLIGHT HARVESTING FIXTURES.

9.

ELECTRICAL CONTRACTOR SHALL PROVIDE AN ALTERNATE BID TO PROVIDE 'CRESTRON'DAYLIGHT SENSING IN ALL ROOMS WITH 'CRESTRON' PANEL CONTROLS IN LIEU OF INDIVIDUALDAYLIGHT HARVESTING FIXTURES.

2.

3

a,EM,A,3

exit

exit

CODE MANUFACTURER &PART NUMBER DESCRIPTION NOTES

A FOCAL POINTFL44-13LED-L35-277-SO-T-BH/L44-SO-RLMG-CD-WH

4.5” RECESSED ROUND 23W LED DOWNLIGHTWITH CLEAR DIFFUSE REFLECTOR & WHITEFLANGE 3500°K

CORRIDORS

B FOCAL POINT “LUNA”FLU-24-B-2T8-E-277-G-PS-NO-WH

2X4, 2-T8 RECESSED INDIRECTWITH ELECTRONIC BALLAST &CENTER PERFORATED BASKET

CFOCAL POINT “MINI-GRAZER”FGM-BB-1T5HO-1C-277-S-SS-WH-LENGTH?

RECESSED WALL SLOT W/60° CUTOFF & WHITEBAFFLE SHIELDING. 1-T5HO IN SECTION.TRIMLESS FLANGE FOR DRYWALL MUD-IN.INTEGRAL ELECTRONIC BALLAST. 12" SLIDINGSLEEVES. 12.6"H X 6" W.

LOWER LEVEL ENTRYHALL DRYWALL MUSTBE LEVEL 5 FINISH

D ELLIPTIPARF306-T255-S-00277-000

3.75”H x 5.9”W x 93.125”L ASYMMETRIC LINEARSURFACE MOUNTED UP LIGHT WITH INTEGRALBALLAST AND 2-T5HO LAMPS

LOWER LEVELENTRY HALL

E AMERLUXSD6-39-T6-E-SD-W-277-WF

6” SQ RECESSED 39W T6 CMH DOWNLIGHTWITH INTEGRAL ELECTRONIC BALLAST, SEMI-DIFFUSE WIDE FLOOD REFLECTOR AND WHITEFLANGE

CAFETERIA

F FOCAL POINT “Equation”FEQ-22-B-1-BX40(25W)-S-277-G-WP

RECESSED 2x2 WITH 3 FLAT LENSES, 1-25WBIAX LAMP, INTEGRAL ELECTRONICBALLAST. FOR GRID CEILING.

F-DIM

FOCAL POINT “Equation”FEQ-22-B-2-BX40(25W)-D-277-G-WP-AR

LECTURE HALLS,CLASSROOMS& OFFICES

F-DAY FOCAL POINT “Equation”FEQ-22-B-2-BX40(25W)-D-277-G-WP- PY1

OFFICES W/EXTERIORFENESTRATION

G FOCAL POINT “Equation”FEQ-24-B-2T8-S-277-G-WP

RECESSED 2x4 WITH 3 FLAT LENSES, 2, T8LAMPS, INTEGRAL ELECTRONIC BALLAST. FORGRID CEILING.

G-DAY FOCAL POINT “Equation"FEQ-24-B-2T8-D-277-G-WP- PY1

RECESSED 2x4 WITH 3 FLAT LENSES, 2-T8LAMPS, INTEGRAL ELECTRONIC DIMMINGBALLAST, 0-10 VOLT DAYLIGHT SENSOR. FORGRID CEILING.

H VISACP4090-10-F50-4-F50-PTD(BRNZ)-DIM-A

45” DIAMETER x 11.5”H SHALLOW BOWL PENDANTWITH MULTI-STEM MOUNT. OVER ALL HEIGHT: 46”10-F50 BIAX LAMPS UP/ 4-F50 BIAX LAMPS DOWN. INTEGRAL ELECTRONIC DIMMING BALLASTFINISH : BRONZE

NO "I"J FOCAL POINT “Verve IV”

FV4S-PL-1T8-1C-277-D-C(Length)-TS-Length

AIRCRAFT SUSPENDED LINEAR DIRECT/INDIRECT WITH 1-T8 LAMP, SEMI-SPECULARPARABOLIC LOUVERS AND INTEGRALELECTRONIC DIMMING BALLAST. FINISH: WHITE

J1 FOCAL POINT “Verve IV”FV4S-PL-2T8-1C-277-D-C(Length)-TS-Length

K ELLIPTIPARF144-T239-S-22-277-000

72” x 5”W x 2 9/16”D SURFACE MOUNTED T5HOWALL WASH WITH INTEGRAL BAFFLE & HPFBALLAST.

CLASSROOMWHITE BOARDS

L MERCURY35E-3-32-OCT-9A.125-ELB-UNI-TG

3T8 2x4 RECESSED TROFFERWITH .125 PRISMATIC LENS & ELECTRONICBALLAST, TRIPLE GASKETED

KITCHEN

L1 MERCURY35E-2-32-OCT-9A.125-ELB-UNI

UTILITYAREASW/CEILINGS

M MERCURY M106N-2-32-OCT-A-ELB-UNI

SURFACE MOUNTED OR SUSPENDED F32T8ACRYLIC WRAP AROUND WITH 1-2 LAMPELECTRONIC BALLAST.

UTILITY AREAS W/OCEILINGS

N FOCAL POINT “FOCUS IV”FW4-NS-2T8-1C-277-E-RC-SS-HW-LENGTH

10”W x 7.75”H RECESSED PERIMETER WALLWASH WITH EXTRUDED SPLAY WITH 6.8”OPENING. 2, T8 LAMPS BEHIND SHIELD.ELECTRONIC BALLAST. SLIDING END SLEEVE.

BATHROOMS

P4 ARCHITECTURAL STARLIGHTINGS-8-V-70MH-WHT-SSCL

70 WATT METAL HALIDE SURFACE MOUNTEDCYLINDER WITH INTEGRAL ELECTRONICBALLAST. 14”H x 7.5”DIAMETER SEMI-SPECULARCLEAR REFLECTOR FINISH: WHITE

P5 ARCHITECTURAL STARLIGHTINGAV7MO70UA / AV714SSCL

70 WATT METAL HALIDE RECESSEDDOWNLIGHT WITH INTEGRAL ELECTRONICBALLAST. 7” DIAMETER APERTURESEMI-SPECULAR CLEAR REFLECTOR

R VISA “IMAGE-BOROUGH”CV1906-2F50-277-PTD(BRNZ)-PTD(BRNZ)

48.4” x 7.3” x 4”D ADA COMPLIANT WALLMOUNTED WITH 2-50 WATT COMPACTFLUORESCENT LAMPS & INTEGRAL ELECTRONICBALLAST FINISH: PAINTED BRONZE

ATRIUM, ARCHITECTTO SPECIFYMOUNTING HEIGHT

RECESSED 2X2 WITH 3 FLAT LENSES, 2-25WBIAX LAMP, INTEGRAL ELECTRONICDIMMING BALLAST & AIR RETURN. FORGRID CEILING.

2X2 RECESSED LUMINAIRE WITH 91.6% EFFICIENCY. 3FLAT ACRYLIC LENSES & 2-25W BIAX LAMPS. INTEGRALELECTRONIC DIMMING BALLAST & INTEGRAL DAY LIGHTSENSOR. FINISH: WHITE

AIRCRAFT SUSPENDED LINEAR DIRECT/INDIRECTWITH 2-T8 LAMPS, SEMI-SPECULAR PARABOLICLOUVERS AND INTEGRAL ELECTRONIC DIMMINGBALLAST. FINISH: WHITE

2T8 2x4 RECESSED TROFFER WITH .125PRISMATIC LENS AND ELECTRONIC BALLAST,TRIPLE GASKETED

LIGHT FIXTURE SCHEDULE

AA FOCAL POINTFL6D-20LED-L35-LD1-277-RO-T/L6-RO-DN-CD-WP

6” DIAMETER, RECESSED 2000 LUMEN3500K LED DOWNLIGHT WITH INTEGRAL0-10V DIMMABLE DRIVER & WHITE FLANGE

BB CUSTOM METALCRAFT “Vulcan”PN-10731-16’-8” DIA. X 60”-F-277-EO-BRONZE-OA

8” DIAMETER X 60”L OPAL ACRYLIC CYLINDERPENDANT WITH T5HO LAMPS, INTEGRAL ELECTRONICBALLAST & METAL BANDING AS SPECIFIED BYARCHITECT. ETCHED OPAL ACRYLIC BOTTOMDIFFUSER. OVER ALL HEIGHT: 16’. FINISH BRONZE

LOWER LEVELVESTIBULE

CC1VISA “VISAGE”CV1660-1FS54-PTD(BRNZ)

47.5”H x 5.25”W x 1”D + 3.5” RECESSED DEPTHWALL ADA COMPLIANT SCONCE WITH ACCENTBARS, 1-T5HO LAMP, INTEGRAL ELECTRONICBALLAST . FINISH: PAINTED BRONZE

LOWER VESTIBULE

CC2VISA “VISAGE”CV1658-1FS24-PTD(BRNZ)

36”H x 5.25”W x 1”D + 3.5” RECESSED DEPTH WALLADA COMPLIANT SCONCE W/ACCENT BARS, 1-T5HO LAMP, INTEGRAL ELECTRONIC BALLAST.FINISH: PAINTED BRONZE

LECTURE HALL

DD FOCAL POINT “AVENUE DMOD-FAVDS-FL-2-T5HO -3C-277-D(Down only)-C24”-MR16-FM-TS-Length

24” AIRCRAFT CABLE SUSPENDED LINEARLUMINAIRE WITH 1-T5HO LAMP WITH FLUSHSATIN LENS DOWN LIGHT AND 1-T5HO UPLIGHT. INTEGRAL DIMMING ELECTRONICBALLAST FOR T5HO (DOWN) LAMPS ONLY.SEPARATE CIRCUITS 4.5”H X 3.2”W. MR16 FLUSHMOUNTS WITH 25° VERTICAL ADJUSTMENT &INTEGRAL TRANSFORMER ALTERNATING WITHT5HO LAMPS. 1 MR16 BETWEEN EACH 4' T5HO.SEPARATE DIMMABLE CIRCUIT

LECTURE HALL

FF ELLIPTIPARF204-X2-55-t-02-277-000

ATRIUM STAIRWELLWALL. MOUNT 3’FROM WALL and 4’ ONCENTER

SEMI-RECESSED ASYMMETRIC WALL WASHW/2-55W BIAX LAMPS IN SECTION, INTEGRALELECTRONIC BALLAST & PARABOLIC CROSSBAFFLE. 4”F x 9 5/8”W x 27 5/8”L

GG ELLIPTIPARF305-T255-S-00-277-000

2.63”H x 5.63”W x 93.125”L ASYMMETRICLINEAR SURFACE MOUNTED UP LIGHT WITHINTEGRAL BALLAST AND 2-T5HO LAMPS

ATRIUM COVE LIGHT

HH FOCAL POINTFL6W-20LED-L35-LD1-277-RO-T/L6-RO-WW-CD-WP

6” DIAMETER, RECESSED 2000 LUMEN3500K LED WALL WASH WITH INTEGRAL0-10V DIMMABLE DRIVER AND WHITEFLANGE

JJ ARCHITECTURAL STARLIGHTING AH6E226UV/AH610Semi-specular

RECESSED 6” DIAMETER DOWNLIGHT WITH2-26W COMPACT FLUORESCENT LAMPS,SEMI-SPECULAR OPEN REFLECTOR ANDINTEGRAL ELECTRONIC BALLAST

R1 VISA “IMAGE-BOROUGH”CV1902-1F50-277-PTD(BRNZ)-PTD(BRNZ)

24.9” x 7.3” x 4”D ADA COMPLIANT WALLMOUNTED WITH 1-50 WATT COMPACTFLUORESCENT LAMPS & INTEGRAL ELECTRONICBALLAST, FINISH: PAINTED BRONZE

ATRIUM ENTRANCE,ARCHITECT TOSPECIFY MOUNTINGHEIGHT

S VISA "CYLINDER"CP4350-4F40-277-1T250PAR38-PTD(BRNZ)-DIM-A-277-OAH:14'0"

11.25" DIAMETER x 30"H ACRYLIC LENS CYLINDERWITH 4-39 WATT COMPACT FLUORESCENTLAMPS AND INTEGRAL ADVANCE MARK-10DIMMING BALLAST FINISH:BRONZE OAH:14'0"

T SE'LUXM1R2S-2T5-OD-TS-LENGTH-277

4” x 4” RECESSED EXTRUDED ALUMINUM LINEARLUMINAIRE WITH EXTRA DIFFUSE LENS. 2-T5STAGGERED LAMPS IN SECTION. 1” ¼-20 STUDSFOR MOUNTING INTEGRAL ELECTRONIC BALLAST

MOUNTVERTICALLY INELEVATORLOBBY WALLS

USE'LUXM10-2T5-MP- F-LENGTH-SV-277-DM-MSO

CONFERENCE ROOMS

ALTERNATE MR16’s &T5 SECTIONS BASEDON TABLE LENGTH

UU VISA “SOUTH BAY”TF1002-1F38-PTD(BLACK)-PTD(BLACK)-WLS-CORD & PLUG

CORD & PLUG TABLE LAMP. 29”H WITH WHITELINEN SHADE 22” DIA. x 8”H. 1-38WFLUORESCENT LAMP & INTEGRAL 120 VOLTELECTRONIC BALLAST. FINISH: BLACK

ATRIUM TABLES

4” x 4” SURFACE MOUNTED LINEAR LUMINAIRE WITH2-T5 LAMPS IN SECTION BEHIND SILKY SPECULARPARABOLIC BAFFLE WITH 6"L INTEGRAL ADJUSTABLEMR16 ACCENTS. SEPARATE DIMMABLE CIRCUITS FORT5 AND MR16 COMPONENTS. INTEGRAL DIMMINGBALLAST FOR T5'S - FINISH: SILVER

L2 MERCURY35E-2-32-OCT-SPW-3/4-ELBD-UNI

CONTROL ROOM 1212T8 2x4 RECESSED TROFFER WITH ¾"PARAWEDGE LOUVER AND ELECTRONICDIMMINGBALLAST

MM

PP TIVOLI “LED FASTUBE”FTL-03-04-WW-Length-12FTL-TC-2030-JT

PARALLEL WIRED 1/4" x 5/16” SEMI-RIGID CLEARTUBE WITH 0.24W WARM WHITE LED’S, 4” ONCENTER. 12VOLT - 3/8” x 1/2” WHITE PVC CHANNELFOR ABOVE - DIMMABLE 12V DC TRANSFORMERSFOR ABOVE - WATTAGE TBD

ACROSS RISERS INCENTER AISLE OFLARGE LECTUREHALL, FIRST FLOOR

RRARCHITECTURAL STARLIGHTINGAH6E226UV /AH630SPCL

WET LOCATION RECESSED 6” DIAMETER DOWNLIGHT WITH 2-26 WATT COMPACT FLUORESCENTLAMPS, SPECULAR CLEAR SPLAY LENS WITHPRISMATIC LENS & INTEGRAL ELECTRONICBALLAST

SS ARCHITECTURAL STARLIGHTING ADV600 /ADV610Semi-specular

6” DIAMETER RECESSED 100 WATT PAR30ADJUSTABLE ACCENT WITH CLEARSEMI-SPECULAR REFLECTOR. 30DEG.VERTICAL ADJUSTMENT

A1 FOCAL POINTFL44-13LED-L35-277-SO-T-BH /L44-SO-DN-CD-WH

4.5” RECESSED SQUARE 23W LED DOWNLIGHTWITH CLEAR DIFFUSE REFLECTOR,REGRESSED LENS & WHITE FLANGE 3500°K

R2 VISA “IMAGE-BOROUGH”OW1294-2F39-277-PTD(BRNZ)-PTD(BRNZ)

36” x 7.3” x 4”D ADA COMPLIANT WALL MOUNTEDWITH 2-39 WATT COMPACT FLUORESCENTLAMPS & INTEGRAL ELECTRONIC BALLAST -FINISH: PAINTED BRONZE - WET LOCATION

KK1 CUSTOM METALCRAFT“ANDROMEDA”PN-10312-36”-3CF26DT-277-DIM-FAB?-BRONZE-OAH?

36”L x 12”H FABRIC COVERED ELLIPTICALPENDANT WITH 3-26W COMPACT FLUORESCENTLAMPS AND INTEGRAL ELECTRONIC DIMMINGBALLAST. CRUCIFORM BRACE. FINISH BRONZE

PRESIDENT'SOFFICE

TT VISA “MIDLAND CRAFTS”CP4810-2QF26-277-PTD(BRNZ)-PTD(BRNZ)

SURFACE MOUNTED 2-26 WATT COMPACTFLUORESCENT LAMP DECORATIVE LUMINAIRE.INTEGRAL ELECTRONIC BALLAST 14 1/8” SQUARE x57/8”H. FINISH PAINTED BRONZE

F-DAY-AR FOCAL POINT “Equation”FEQ-22-B-2-BX40(25W)-D-277-G-WP-AR-PY1

RECESSED 2x2 WITH 3 FLAT LENSES, 2-25W BIAXLAMP, INTEGRAL ELECTRONIC DIMMINGBALLAST, 0-10 VOLT DAYLIGHT SENSOR. FORGRID CEILING.

F-DIM-AR

F-AR FOCAL POINT “Equation”FEQ-22-B-1-BX40(25W)-S-277-G-WP-AR

RECESSED 2x2 WITH 3 FLAT LENSES, 1-25WBIAX LAMP, INTEGRAL ELECTRONICBALLAST & AIR RETURN. FOR GRID CEILING.

LAMPS

INCLUDED

2-F32T8/ADV83536,000 HRS.3100 LUMENONLY

1-F45T5/841/HO

2-F45T5/835/HO

1-CDM35/T6/839

2-PL-L40W/835/XEW/4P/IS25W

2-F32T8/ADV835

2-F32T8/ADV835

14-FT50W/2G11/835

1-F32T8/ADV835

2-F32T8/ADV835

2-F39T5/385/HO

3-F32T8/ADV835

2-F32T8/ADV835

2-F32T8/835

2-F32T8/ADV835

1-MHC70/U/MP/3K

1-MHC70/U/MP/3K

2-FT50W/2G11/RS/835

1-FT50W/2G11/RS/835

4-FT40W/2G11/8351-60PAR38/IRC/HAL/FL40°

2-F28T5/835

2-F28T5/8351-50MR16/FL40(EXN) 12 VOLT

Z

W FOCAL POINT “TWELVE”FTWS-PB-1T5HO-1C-277-D-J-12-EC-TS-LENGTH

EXIT

48"x9"Wx1.43"H PARALLEL BLADE BAFFLE WITHCU FILTER, T5HO LAMP, SINGLE CIRCUIT, WITHELECTRINIC DIMMING BALLAST AND SILVERFINISH

LUMINAIRETSL9-4-112WHP-3500K-2B-277-OP-BLACK

9.40”W x 4”D x 48.45”L ADA COMPLIANT VANDALRESISTANT POLYCARBONATE OPAL LENS WITHONE ROW LED CONSTANTLY ON AND ONE ROWSENSORED, BUILT IN SENSOR,112W, 3500KLED'S. FINISH: BLACK

STAIRWELLSARCHITECT TOSPECIFY MOUNTINGHEIGHT AFF

Z1LUMINAIREVPF84-232-ELECT-277-OP-BLACK-WET

8.75”W x 4”D x 49.68”L VANDAL RESISTANT WETLOCATION POLYCARBONATE OPAL LENS WITH56W 3500K LED'S. FINISH: BLACK

PARKING AREAS

XX PRISMA "OPTALUM 36"093740 / 2793 / 299

14.2" DIAMETER x 11"H FROSTED REFRACTORPENDANT WITH FROSTED DIFFUSER DISC & 75"FIELD CUT STRAIGHT FEED WIRE. 1-42 WATTCOMPACT FLUORESCENT LAMP & INTEGRALELECTRONIC BALLAST OVERALL HEIGHT: 88.5".METAL FINISH: CHROME

YY PRISMA "OPTALUM 19"073730 / 2781 / MATGLASS LENS

1-F45T5/835/HO

EVELITETEX-R-#Faces

LEDINCLUDED

CORRIDORS, OFFICES

NO "O"

NN LUCIFERDL2RXM / DH-NIC-XF-HAL-50-277

1.88” DIAMETER RECESSED MR16 ADJUSTABLEACCENT WITH 45° VERTICAL ADJUSTMENTINTEGRAL ELECTRONIC TRANSFORMER

ROOM 202LDEAN’S OFFICE

K1 ELLIPTIPARF144-T139-S-22-277-000

36” x 5”W x 2 9/16”D SURFACE MOUNTED T5HOWALL WASH WITH INTEGRAL BAFFLE & HPFBALLAST.

CLASSROOMWHITE BOARDS

1-F39T5/385/HO

2-F32T8/ADV835

2-FT39W/2G11/RS/835

TO BEDETERMINED

1-F45T5/835/HO

1-F39T5/835/HO

2-F45T5/835/HO(DOWN)

1-50MR16/NFL/25° (EXZ 12VOLT)

2-FT55W/2G11/835

2-F45T5/835/HO

INCLUDED

2-CFQ26W/G24q/835

3-CFQ26W/G24q/835

1-50MR16/VWFL55° (FNV)

0.24W T 13/4WWW(INCLUDED)

2-CFQ26W/G24q/835

1-60PAR30/IRC/HAL/WFL40°

2-CFQ26W/G24q/835

1-F38/2D/835/4P

WW DESIGN PLAN "LINEAR LED"AV1-L-LED-CZ-1-FINISH?-0-120V-C

27" x 3.5"W x 3"H SURFACE MOUNTED WETLOCATION ASYMMETRIC WALL GRAZER WITHNARROW BEAM OPTICS. 12-3 WATT 35K LED'S &INTEGRAL 120 VOLT DRIVER. CLEARPOLYCARBONATE LENS & 3" DEEP BRACKET

INCLUDED ARCHITECT TOSPECIFY MOUNTINGHEIGHT ABOVEGRADE AIMDOWNWARD.

1-CFTR42W/GX24q/835

7.5" DIAMETER x 7"H FROSTED REFRACTORPENDANT WITH FROSTED DIFFUSER DISC & 75"FIELD CUT STRAIGHT FEED WIRE. 1-26 WATTCOMPACT FLUORESCENT LAMP & INTEGRALELECTRONIC BALLAST. OVERALL HEIGHT: 88.5".METAL FINISH: CHROME

1-CFQ26W/G24q/835

ZZTIVOLI "COVELUME 120"CVL1-20-U-32-120V-LENGTH?

5.5W 1.5"H x 1 7/16" W x 4 1/4"L MODULECOVE LIGHT, WITH 4, 3200K LED CLUSTERS 2.5"ON CENTER. ADJUSTABLE DIRECTIONALMOUNTING 120V

EXECUTIVECONFERENCE ROOMSMAX. RUN LENGTH =200' SET MTG AT 30°

INCLUDED

AAA Cyclone CL61T4-FLPC-GR3-70MH-277-EA1-DFP-F1AP-TE-W1-Finish

UNIVERSAL SURFACE MOUNTED RED LETTER ONCLEAR BACKGROUND LED EXIT SIGN

70 WATT METAL HALIDE WALL MOUNTEDDECORATIVE HEXAGONAL LANTERN WITH FLATCLEAR TEMPERED GLASS LENSES, INTEGRALELECTRONIC BALLAST. TYPE 3 OPTICS. FINIAL& DECORATIVE TEETH. 36”H x 20 ¾" DIAMETER

CODE MANUFACTURER &PART NUMBER DESCRIPTION NOTES

LIGHT FIXTURE SCHEDULE

LAMPS

BBBLSI INDUSTRIES “Greenbriar”GBWS-3-26-CFL2-F-277-BRZ-CWBB

2-26 WATT COMPACT FLUORESCENT WETLOCATION WALL MOUNTED WITH TYPE IIIOPTICS, INTEGRAL ELECTRONIC BALLAST.FINISH: BRONZE. DARK SKY COMPLIANT

2-CFTR26W/Gx24q/835

CCCH.E.WILLIAMSSWL-50PSMH-277-FTG-DBR

50 WATT METAL HALIDE RECESSED STEPLIGHT WITH TEMPERED GLASS LENS &INTEGRAL ELECTRONIC BALLAST, FINISH:BRONZE 14 3/8”L x 7 3/8”H x 6”D

4th Floor Terrace

LECTURE HALLS,CLASSROOMS& OFFICES

CORRIDORS, OFFICES

2-PL-L40W/835/XEW/4P/IS25W

2-PL-L40W/835/XEW/4P/IS25W

1-PL-L40W/835/XEW/4P/IS25W

1-PL-L40W/835/XEW/4P/IS25W

2-PL-L40W/835/XEW/4P/IS25W

FOCAL POINT “Equation”FEQ-22-B-2-BX40(25W)-D-277-G-WP

LECTURE HALLS,CLASSROOMS& OFFICES

RECESSED 2x2 WITH 3 FLAT LENSES, 2-25WBIAX LAMP, INTEGRAL ELECTRONICDIMMING BALLAST. FOR GRID CEILING.

G-AR FOCAL POINT “Equation”FEQ-24-B-2T8-S-277-G-WP-AR

RECESSED 2x4 WITH 3 FLAT LENSES, 2, T8LAMPS, INTEGRAL ELECTRONIC BALLAST ANDAIR RETURN. FOR GRID CEILING.

2-F32T8/ADV835

LECTURE HALLS,CLASSROOMS& OFFICES

1-MHC70/U/M/3K

FOCAL POINTFL6D-20LED-L35-LD1-277-RO-T/L6-RO-DN-CD-WP

6” DIAMETER, RECESSED 2000 LUMEN3500K LED DOWNLIGHT W/ INTEGRAL0-10V DIMMABLE DRIVER AND WHITEFLANGE

INCLUDED

INCLUDED

INCLUDED

FFF FOCAL POINT “Vault”FVAL-22-CN-LL2-L35-LD1-277-G-AR-WH

RECESSED 2x2 LED FIXTURE WITH AIR RETURN,AND WHITE FINISH FOR STANDARD GRID

M.R.O. SUITELEDINCLUDED

J4 FOCAL POINT “Verve IV” 4'-0" LONG SECTION INCORPORATED WITH TYPE'J' OR 'J1' WITH 3 LAMPS. TWO OUTER LAMPS TOBE WIRED VIA ELECTRONIC DIMMING BALLASTAND CENTER LAMP TO HAVE ELECTRONICNO-DIMMING BALLAST. CENTER LAMP TO BEWIRED TO EMERGENCY CIRCUIT.

3-F32T8/ADV835

LEDINCLUDED

LEDINCLUDED

R2a VISA “IMAGE-BOROUGH”CV1904-2F39-277-PTD(BRNZ)-PTD(BRNZ)

36” x 7.3” x 4”D ADA COMPLIANT WALL MOUNTEDWITH 2-39 WATT COMPACT FLUORESCENTLAMPS & INTEGRAL ELECTRONIC BALLAST -FINISH: PAINTED BRONZE - WET LOCATION

2-FT39W/2G11/RS/835

TMGEngineeringInc.

TMG JOB NUMBER

Fax: 732-738-9672

1090 King Georges Post Rd.Suite No. 903Edison, New Jersey 08837Phone: 732-738-9670

New Jersey Certificate of AuthorizationNumber 24GA28081900

Consulting Mechanicaland Electrical Engineers

ISSUE DATE:

SHEET NUMBER:

SHEET TITLE:

Copyright (c) by Environetics, Inc. All Rights Reserved.

CHECKED BY:

DRAWN BY:

PROJECT NUMBER:

DESIGN DELIVERABLE:

REV DATE DESCRIPTION

CLIENT:

PROJECT TEAM:

SEAL

:

Structural Engineer:Environetics Design1617 JFK BLVD.,Suite 1600Philadelphia, PA 19103

Montclair, New Jersey

CLIE

NT:

Architect:Environetics Group Architects180 Sylvan Ave.Englewood Cliffs, NJ 07632

MEP Engineer:TMG Engineering Inc.1090 King Georges Post RoadSuite 903Edison, NJ 08837

Civil Engineer:Langan Engineering & Environmental Services619 River DriveCenter 1Elmwood Park, NJ 07407-1338

AV / IT / Security / Accoustical Consultant:The Sextant Group Inc.730 River AvenuePittsburgh, PASuite 600 15212

MO

NTC

LAIR

STA

TE U

NIV

ERSI

TYSC

HO

OL

OF

BUSI

NES

SM

ONT

CLAI

R, N

EW J

ERSE

Y

ADDENDUM NO. 2

06/17/13

6/14

/201

3 3:

29:1

3 PM

E-1

ELECTRICAL -LEGEND,SCHEDULES,NOTES ANDDETAILS

Mon

tcla

ir S

t ate

Uni

vers

ity

P.B.

Ken S.

10-115

Montclair StateUniversity

10-115

FRANK S. RADOSIN N.J.P.E. 33923

M M

M M

M

M M

M M

M M

M M

M M

M M

M

M

M

M

M M

M M

M

M

M M

M

MM

M

M M

1 2 4 5 6 9 12 15 16 18

A

B

H

K

L

M

N

O

C

P

17

D

11 14

G

I

197 8 12.1 14.7

E

F

J

Q

3

18.9

15.1 16.2 16.9

E.1

J.9

16.110

STAIRS0S01

UCLASSROOM

015

INCUBATORSPACE

014

CORRIDOR0C03

CORRIDOR0C04

CAFE070

OFFICE080B

DIRECTOR080A

STAIR0S03

VESTIBULE0C08

UCLASSROOM

025

CORRIDOR0C05

KITCHEN001B

KITCHEN001A

TRADINGFLOOR

001

COOLER002C

FREEZER002A

VESTIBULE0C01

CONFERENCE012

UCLASSROOM

021

ELEC.0E01

WOMEN'SRESTROOM

0R01

MEN'SRESTROOM

0R02

AV/IT0D01

CORRIDOR0C06

CATERINGSETUP002B

CORRIDOR0C02

UCLASSROOM

011

STAIRS0S05

MEN'SLOCKERS

048

UNISEXRESTROOM

0R03

OFFICE052

ELEV.MACH.0M02

LP-LA3

NOTES :

1. EMERGENCY FIXTURES, TYPE 'J4' IN ROOMS 011, 015, 021 AND 025 SHALL HAVE THEIR THIRD LAMP WIRED DIRECTLY TO EMERGENCY POWER CIRCUIT 'ELP-A-10'. THE INTENT IS FOR THESE LAMPS TO BE ENERGIZED ONLY IN THE EVENT OF THE EMERGENCY GENERATOR RUNNING. PROVIDE A LINE 24 RELAY TO ENERGIZE LAMPS ONLY IN THE EVENT OF POWER LOSS.

2. POWER CIRCUITS FOR ALL LIGHTING, SHADES, SCREENS, ETC. INDICATED WITHIN ROOMS WITH CRESTRON PANELS SHALL BE CIRCUITED THROUGH CRESTRON PANEL.

3. ALL CORRIDOR LIGHTING SHALL BE CONTROLLED VIA LOCAL SWITCHES WITH OVERRIDE 'OFF' BY B.M.S. ALL STAIRWELL LIGHTING SHALL BE CONTROLLED BY B.M.S. SYSTEM PROVIDE LIGHTING RELAYS AND CONTACTORS AS REQUIRED.

4. EXIT DOOR EGRESS LIGHTING SHALL BE PHOTOCELL CONTROLLED VIA FAIL 'OFF' PHOTO CELLS.

5. MECHANICAL ROOM, ELECTRICAL ROOM AND AV/IT ROOM SHALL BE CONTROLLED BY LOCAL SWITCHES ONLY.

6. LOADING DOCK SHALL BE CONTROLLED VIA LOCAL SWITCHES WITH OVERRIDE 'OFF' BY B.M.S.

7. CONNECT DESIGNATED 'EM' CORRIDOR AND ROOM LIGHTS TO EMERGENCY CIRCUIT ELP-A-2. ALL EMERGENCY LIGHTING SHALL REMAIN ON (UNSWITCHED) AS NIGHT LIGHTING.

8. STAIRWELL LIGHTING SHALL BE CONNECTED TO EMERGENCY CIRCUIT ELP-A-3.

9. ALL ELECTRIC PANEL LOCATIONS ARE INDICATED ON POWER DRAWINGS.

10. ALL NORMAL POWER LIGHTING CIRCUITS INDICATED ARE IN PANEL "LP-LA", UNLESS OTHERWISE NOTED. ALL NORMAL POWER LIGHTING CIRCUITS SHALL BE WIRED THROUGH FLOOR LIGHTING RELAY PANEL AND CONTROLLED VIA 'B.M.S.' SYSTEM.

11. COORDINATE ALL FIXTURE TYPES WITH ARCHITECTURAL CEILING PLANS PRIOR TO ORDERING.

12. CONTRACTOR SHALL WIRE ALL LIGHTING WITHIN THIS SPACE TO BE CONTROLLED BY BUILDING 'B.M.S.' SYSTEM. ALL EMERGENCY LIGHTING TO REMAIN ON (UNSWITCHED) AS NIGHT LIGHTING.

13. EMERGENCY LIGHTING WITHIN THIS SPACE SHALL BE WIRED THROUGH 'CRESTRON' PANEL WITH A PHASE LOSS SENSOR TO TURN ALL EMERGENCY FIXTURES ON TO FULL BRIGHTNESS IN THE EVENT OF POWER LOSS ON THE NORMAL AND/OR EMERGENCY CIRCUIT FOR THE SPACE.

14. ALL OCCUPANCY SENSORS, WALL MOUNTED OR CEILING MOUNTED WITH OVERRIDE SWITCH SHALL BE PROGRAMMED TO BE MANUAL ON AUTO OFF. TIME DELAY FOR UNOCCUPIED SPACE SHALL BE AS DIRECTED BY THE UNIVERSITY.

15. CONTRACTOR SHALL PROVIDE AN ALTERNATE BID TO USE A SINGLE DAYLIGHT SENSOR TIED INTO ROOM 'CRESTRON' PANEL WHERE APPLICABLE IN LIEU OF DAYLIGHT HARVESTING FIXTURES.

16. ALL 'CRESTRON' PANELS INDICATEDED IN ROOMS WITHOUT CLOSETS FOR THE PANEL SHALL BE LOCATED ABOVE DROPPED CEILING.

17. ALL OCCUPANCY SENSORS WITHIN STUDY ROOMS SHALL BE CAPABLE OF INTERFACING WITH ROOMS A/V EQUIPMENT.

18. ALL LIGHTING DESIGNATED WITH DAYLIGHT HARVESTING FEATURE WITHIN ROOMS THAT ARE BEING CONTROLLED WITH 'CRESTRON' PANELS SHALL BE CONTROLLED VIA A SINGLE DAYLIGHT SENSOR WITHIN SPACE. REFER TO 'CRESTRON' DETAILS AND SPECIFICATIONS FOR MORE INFORMATION.

F-AR-DAY

3

A,EM A,13

A,EM A,EM A,EM A,EM A,EM

A,13 A,13 A,13 A,13 A,13 A,13A,13

A,13

A,13

A,13

A,13

A,13

A,13

A,13

A,13

A,13

A,13

A,13A,13A,13A,13

A,13A,13

A,13 A,13 A,13 A,13

A,13

C,13

c,K b,KJ g J h

a,J4EM

a,J a,J4EM

d,J d,J4EM

d,J

d,J4EM

d,J d,J4EM

e,AA e,AA e,AAe,AA

C C

e,F-DIM

e,F-DIM

e,F-DIM

e,F-DIMe,F-DIM

e,F-DAY

e,F-DAY

e,F-DAY

S f

S f

EM,Z

EM,ZF-DAY-AR,15

M

M

F-DAY-AR,15

CC1,15 CC1,15

CC1,15 CC1,15

c,K b,KJ g J h

4

e,AAe,AA e,AAe,AA

C C

e,F-DIM

e,F-DIM

e,F-DIM

e,F-DIM

e,F-DIM

e,F-DIMe,F-DIMe,F-DIM

CRESTRONPANEL

LP-LA4

CRESTRONPANEL

LP-LA6

N,EM

N,12

N,12

N,12

N,12

N,12

N,EM

N,12

N,12

N,12

N,12

N,EM

N,12

N,12 N,12

N,12 N,12

N,12 N,EM

N,12

N,12

N,12

3

3

L1,EM

L1,EM

M,EM

M,EMM,12

M,12M,12

M,12M,EMN,EM

N,12

M

LP-LA5

LP-LA7

CRESTRONPANEL

CRESTRONPANEL e,F-DIM e,F-DIM e,F-DIM e,F-DIM

e,F-DIM

e,F-DIMe,F-DIM

e,F-DIMe,F-DIM

e,F-DIM

a,J4EM

a,J a,J4EM

d,J4EM

d,J d,J4EM

d,J d,J4EM

d,J

S f

S f

MOTORIZED SHADECONTROL (TYPICAL)

C C C C

e,AA e,AA e,AA e,AA e,AA e,AA e,AA e,AA

c,K b,KJ g J h

c,K b,KJ g J h

MOTORIZED SCREENCONTROL (TYPICAL)

A,EM A,EM A,EM A,EM A,11

A,11A,11

C,11

A,EM

A,EM

A,11

A,11

A,11 A,11

A,11 A,11

A,11A,11

A,11A,11 A,11

A,11 A,11

A,11

A,11

A,11

A,11

A,11

A,11A,11

A,11 A,11

Z1,10 Z1,10 Z1,10

Z1,10 Z1,10 Z1,10

Z1,10 Z1,10 Z1,10

Z1,10 Z1,10 Z1,10

Z1,10 Z1,10 Z1,10

Z1,10 Z1,10 Z1,10

3

A,11

Z,EM

R2,10 R2,10 R2,10 R2,10 R2,10

A,EM

A,EM

NN,12

A,12 A,12

NN,12

NN,12

A,12 A,12

R1,12

R1,12

A,EM

A,EM

A,EM

A,EM

A,EM

A,EM

A,EM

H,EM

3

3

4

A,11

A,11A,11

A,11

A,11A,11

A,11 A,11A,11

A,11A,11 A,11

A,13 A,13

A,13

A,13 A,13

A,13

A,13 A,13

A,13

A,13 A,13

A,13

A,13 A,13

A,13

4

M,EM

M

e,AA e,AA

e,AA e,AA

b,K

J f

c,K

J g

CC

d,Wd,W

CRESTRONPANELLP-LA

8ELP-A

10

3

3

3

33

M

3

MM

M

4

L1,11 L1,EM L1,11 L1,11 L1,11 L1,EM L1,11

b,L,14b,L,14

b,L,14

a,L,EM

L,EM

c,L,14L,EMc,L,14

c,L,14c,L,14c,L,14

d,L,14 L,EM d,L,14

M

AA,14 AA,14 AA,14 AA,14 AA,14 AA,14

AA,14

AA,14

AA,14

AA,14

AA,14

AA,14

AA,14

AA,14

AA,14

AA,14

AA,14

AA,14

AA,14

AA,14AA,14

NN,14 NN,14

NN,14 NN,14

NN,14 NN,14

NN,14 NN,14

AA,14

AA,EM AA,14 AA,EM

AA,14

AA,14 AA,EM AA,14

AA,14 AA,14 AA,14

AA,EM AA,14 AA,EM

AA,14 AA,EM

AA,14AA,14AA,14

AA,14

AA,14AA,14AA,14

AA,14

AA,14 AA,EM AA,14

AA,14

C,14 C,14 C,14 C,14

YY,14

YY,14

YY,14

YY,14

YY,14

YY,14

YY,14 YY,14 YY,14 YY,14 YY,14

YY,14

YY,14

YY,14

YY,14

XX,14 XX,14

XX,14 XX,14XX,14

XX,14 XX,14XX,14

XX,14 XX,14XX,14

XX,14 XX,14

L1,10

L1,10

L1,10

M,EM

M,10

M,10M,10

M,10M,10M,EM

M,EM

M,10

M,10

M,EM

M,10

M,10

M,10

M,10

M,10

M,EM

M,10

M,EM

M,10

M,10

M,10

M,10

exit

exit

exit

exit

exit

exit

exit exit

exit

exitexit

exit

exit

exit

exit exit

exit

exit

exit

exitexitexit

exit

exit

exit

exit

exit

exit

exit

exit

exit

exit

exit

exit exit

exit

exit

ELP-A7

ELP-A7

ELP-A7

ELP-A7

ELP-A7

ELP-A7

ELP-A7

AA,EM

ELP-A7

AA,EM

ELP-A7

AA,EM

ELP-A7

AA,EM

ELP-A7

AA,EM

ELP-A7

ELP-A7

ELP-A7

ELP-A7

ELP-A7ELP-A

7ELP-A

7

NN

exit

exit

exit

exit

ELP-A7

ELP-A7

ELP-A7

ELP-A7

ELP-A7

ELP-A7

ELP-A7

ELP-A7

WOMEN'SLOCKERS

050

HK LUNCH046

HOUSKEEPING044

UNISEXRESTROOM

0R04

exit

exit

CONTRACTOR SHALLCOORDINATE LIGHTING

LAYOUT WITH ALLMECHANICAL

ROOM EQUIPMENT

exit

exit

LAMPHOLDER AND SWITCHIN ELEVATOR PIT

LAMPHOLDER AND SWITCHIN ELEVATOR PIT

exit

PARKING AREA PARKING AREA

RP-LA62

RP-LA62

L1,10

a,J4EM

a,J a,J4EM

d,J d,J4EM

d,J

d,J4EM

d,J d,J4EM

e,F-DAY

e,F-DAY

e,F-DIM e,F-DIM e,F-DIMe,F-DAY

a,J4EM

a,J a,J4EM

d,J4EM

d,J d,J4EM

d,J d,J4EM

d,J

WW,ELP-A-12

WW,ELP-A-12

WW,ELP-A-12

WW,ELP-A-12

WW,ELP-A-12

WW,ELP-A-12

WW,ELP-A-12

WW,ELP-A-12

WW,ELP-A-12

WW,ELP-A-12

WW,ELP-A-12

WW,ELP-A-12

WW,ELP-A-12

WW,ELP-A-12

WW,ELP-A-12

Z,EM

N,12

F-DAY-AR,15 F-DAY-AR,15F-DAY-AR,15

XX,14XX,14

AA,14

XX,14

AA,14

NN,12

NN,12

AAA,ELP-A-12

AAA,ELP-A-12

AAA,ELP-A-12

AAA,ELP-A-12

AAA,ELP-A-12

AAA,ELP-A-12

BLOOMBERG090

CENTERFOR

ENTREPENEURSHIP080

M

F-DAY-AR,15F-DAY-AR,15

exit

F-AR,15

F-AR,15

F-AR,15

F-AR,15F-AR,15

F-DAY-AR,15

F-AR,15

F-AR,15

F-AR,15

F-DAY-AR,15

F-AR,15

F-DAY-AR,15

F-AR,15

F-DAY-AR,15

F-AR,15

F-DAY-AR,15

F-AR,15

F-DAY-AR,15

F-AR,15

F-AR,15

F-AR,15

c,b,U

U,EM

c,b,U

c,b,U

c,b,U

c,b,U

a,b,U

a,b,U

W

W

W

W,EM

W

W

W,EM

W

W

W

4

M

EM,a,W d,W EM,d,W

d,Wd,WEM,a,W d,W EM,d,W

d,Wa,W d,W d,Wd,W

d,WEM,a,W d,W EM,d,Wd,W

d,Wa,W d,W d,Wd,WA,12

A,12

REFER TONOTE #12

3,c

3,c

ab

d

REFER TONOTE #12

REFER TONOTE #13

REFER TONOTE #13

CRESTRONPANEL

LP-LA-15ELP-A-10

CRESTRONPANEL

LP-LA-15ELP-A-10

INDICATES 'NORMAL' AND'EMERGENCY' CIRCUITFOR LIGHTING WITHINROOM. WIRE LIGHTINGTHROUGH 'CRESTRON'PANEL (TYPICAL)

CONTROLS FLUORESCENTPORTION OF FIXTURE(TYPICAL)

CONTROLS 'MR' PORTIONOF FIXTURE - TYP.

exit

exit

exit

LP-LA3

F-AR-DAY

LP-LA3

F-AR-DAY

LP-LA3

F-AR-DAY

LP-LA3

F-AR-DAY

LP-LA3

F-AR-DAY

LP-LA3

F-AR-DAY

LP-LA3

F-AR-DAY

LP-LA3

F-AR

LP-LA3

F-AR

LP-LA3

F-AR

LP-LA3

F-AR

LP-LA3

F-AR

LP-LA3

F-AR

ELP-A10

EM,F-AR

LP-LA3

F-AR

LP-LA3

F-AR

ELP-A10

EM,F-AR

ELP-A10

EM,F-AR

ELP-A10

EM,F-AR

REFER TONOTE #12

F-DAY-AR,15

M

OFFICE080C

d,J d,J

d,J d,J

A,EMA,15

A,EM

A,EM

A,15 A,15

A,15

A,15A,15

A,15

GG,15

GG,15

GENERAL LIGHTING NOTE :

Contractor shall reference the Architectural RCP drawingsfor fixture location, type, and count. Reference ElectricalLighting plans for circuiting and electrical notes.

TMGEngineeringInc.

TMG JOB NUMBER

Fax: 732-738-9672

1090 King Georges Post Rd.Suite No. 903Edison, New Jersey 08837Phone: 732-738-9670

New Jersey Certificate of AuthorizationNumber 24GA28081900

Consulting Mechanicaland Electrical Engineers

ISSUE DATE:

SHEET NUMBER:

SHEET TITLE:

Copyright (c) by Environetics, Inc. All Rights Reserved.

CHECKED BY:

DRAWN BY:

PROJECT NUMBER:

DESIGN DELIVERABLE:

REV DATE DESCRIPTION

CLIENT:

PROJECT TEAM:

SEAL

:

Structural Engineer:Environetics Design1617 JFK BLVD.,Suite 1600Philadelphia, PA 19103

Montclair, New Jersey

CLIE

NT:

Architect:Environetics Group Architects180 Sylvan Ave.Englewood Cliffs, NJ 07632

MEP Engineer:TMG Engineering Inc.1090 King Georges Post RoadSuite 903Edison, NJ 08837

Civil Engineer:Langan Engineering & Environmental Services619 River DriveCenter 1Elmwood Park, NJ 07407-1338

AV / IT / Security / Accoustical Consultant:The Sextant Group Inc.730 River AvenuePittsburgh, PASuite 600 15212

MO

NTC

LAIR

STA

TE U

NIV

ERSI

TYSC

HO

OL

OF

BUSI

NES

SM

ONT

CLAI

R, N

EW J

ERSE

Y

ADDENDUM NO. 2

06/17/13

6/14

/201

3 3:

29:3

9 PM

E-2

ELECTRICAL -LOWER LEVELLIGHTING PLAN

Mon

tcla

ir S

t ate

Uni

vers

ity

P.B.

Ken S.

10-115

Montclair StateUniversity

10-115

FRANK S. RADOSIN N.J.P.E. 33923

1/8" = 1'-0"1 ELECTRICAL - LOWER LEVEL LIGHTING PLAN

M

M

M

M

M

M M

M

M M

MM

M

M

M

M

MM

MM

MM

M

M M

MM M

M M

M M

M

M

M

M

M

M

M

M

M

1 2 4 5 6 9 12 15 16 18

A

B

H

K

L

M

N

O

C

P

17

D

11 14

G

I

197 8 12.1 14.7

E

F

J

Q

3

18.9

15.1 16.2 16.9

E.1

J.9

16.110

OFFICE170E

CORRIDOR1C04

OFFICE170C

UCLASSROOM

124

STUDY134

STUDY136

STUDY138

VESTIBULE1C01

INTERVIEWROOM170H

INTERVIEWROOM170G

OFFICE170A

GRADASSISTANT

170R

MEN'SRESTROOM

1R02

WOMEN'SRESTROOM

1R01

INTERVIEWROOM170Q

STUDY125

STUDY119

STUDY123

SEMINAR118

IT1D01

PROJECTIONAV/IT101A

INTERVIEWROOM170J

OFFICE170D

OFFICE170B

UCLASSROOM

128CLUBS

130

CCLASSROOM

110

UCLASSROOM

114

OFFICE170L

OFFICE170K

CORRIDOR102U

MAIL/STORAGE170P

FILES170N

CORRIDOR1C06

CLOSET140B

EXECUTIVEED.

MULTIPURPOSEROOM

140

STAIRS1S03

STAIRS1S01

HK1J01

CORRIDOR1C05

LOBBY1C07

CONFERENCE172

STUDENTSERVICES

170

CORRIDOR1C03

CORRIDOR1C02

ATRIUM100

SBUSTEACHING

LAB120

CRESTRONPANEL

e,AA

C

a,J

d,J4EM

d,J

c,K b,KJ g

S f S f

e,F-DIM

e,F-DAY

a,J4EM

d,J

d,J4EM

d,J

J g

e,AA e,AA e,AA

e,F-DIM

e,F-DAYe,F-DAY

e,F-DAYe,F-DAYe,F-DAY

C

MOTORIZED SHADECONTROL (TYPICAL)

MOTORIZED SCREENCONTROL (TYPICAL)

NOTES :

1. EMERGENCY FIXTURES, TYPE 'J4' IN ROOMS 110, 114, 120, 124 AND 128 SHAL HAVE THEIR THIRD LAMP WIRED DIRECTLY TO EMERGENCY POWER CIRCUIT 'ELP-A-11'. THE INTENT IS FOR THESE LAMPS TO BE ENERGIZED ONLY IN THE EVENT OF THE EMERGENCY GENERATOR RUNNING. PROVIDE A LINE 24 RELAY TO ENERGIZE LAMPS ONLY IN THE EVENT OF POWER LOSS.

2. POWER CIRCUITS FOR ALL LIGHTING, SHADES, SCREENS, ETC. INDICATED WITHIN ROOMS WITH CRESTRON PANELS SHALL BE CIRCUITED THROUGH CRESTRON PANEL.

3. ALL CORRIDOR LIGHTING SHALL BE CONTROLLED VIA LOCAL SWITCHES WITH OVERRIDE 'OFF' BY B.M.S. ALL STAIRWELL LIGHTING SHALL BE CONTROLLED BY B.M.S. SYSTEM PROVIDE LIGHTING RELAYS AND CONTACTORS AS REQUIRED.

4. EXIT DOOR EGRESS LIGHTING SHALL BE PHOTOCELL CONTROLLED VIA FAIL 'OFF' PHOTO CELLS AND SHALL BE ON EMERGENCY CIRCUIT WITH CORRIDOR LIGHTING.

5. ELECTRICAL ROOM AND AV/IT ROOM SHALL BE CONTROLLED BY LOCAL SWITCHES ONLY.

6. CONNECT DESIGNATED 'EM' CORRIDOR AND ROOM LIGHTS TO EMERGENCY CIRCUIT ELP-A-8. ALL EMERGENCY LIGHTING SHALL REMAIN ON (UNSWITCHED) AS NIGHT LIGHTING.

7. STAIRWELL LIGHTING SHALL BE CONNECTED TO EMERGENCY CIRCUIT ELP-A-3.

8. CIRCUIT 'b' AND STAIR / WALKWAY ILLUMINATION (DOWNLIGHTING) IN LECTURE HALL #101 SHALL BE EMERGENCY LIGHTING CIRCUIT. WIRE THROUGH 'CRESTRON' PANEL FEATURE. REFER TO CRESTRON DETAILS.

9. ALL ELECTRIC PANEL LOCATIONS ARE INDICATED ON POWER DRAWINGS.

10. ALL NORMAL POWER LIGHTING CIRCUITS INDICATED ARE IN PANEL "LP-1A", UNLESS OTHERWISE NOTED. ALL NORMAL POWER LIGHTING CIRCUITS SHALL BE WIRED THROUGH FLOOR LIGHTING RELAY PANEL AND CONTROLLED VIA 'B.M.S.' SYSTEM.

11. COORDINATE ALL FIXTURE TYPES WITH ARCHITECTURAL CEILING PLANS PRIOR TO ORDERING.

12. EMERGENCY LIGHTING WITHIN THIS SPACE SHALL BE WIRED THROUGH 'CRESTRON' PANEL WITH A PHASE LOSS SENSOR TO TURN ALL EMERGENCY FIXTURES ON TO FULL BRIGHTNESS IN THE EVENT OF POWER LOSS ON THE NORMAL AND/OR EMERGENCY CIRCUIT FOR THE SPACE.

13. ALL OCCUPANCY SENSORS, WALL MOUNTED OR CEILING MOUNTED WITH OVERRIDE SWITCH SHALL BE PROGRAMMED TO BE MANUAL ON AUTO OFF. TIME DELAY FOR UNOCCUPIED SPACE SHALL BE AS DIRECTED BY THE UNIVERSITY.

14. CONTRACTOR SHALL PROVIDE AN ALTERNATE BID TO USE A SINGLE DAYLIGHT SENSOR TIED INTO ROOM 'CRESTRON' PANEL WHERE APPLICABLE IN LIEU OF DAYLIGHT HARVESTING FIXTURES.

15. ALL 'CRESTRON' PANELS INDICATEDED IN ROOMS WITHOUT CLOSETS FOR THE PANEL SHALL BE LOCATED ABOVE DROPPED CEILING.

16. ALL OCCUPANCY SENSORS WITHIN STUDY ROOMS SHALL BE CAPABLE OF INTERFACING WITH ROOMS A/V EQUIPMENT.

17. ALL LIGHTING DESIGNATED WITH DAYLIGHT HARVESTING FEATURE WITHIN ROOMS THAT ARE BEING CONTROLLED WITH 'CRESTRON' PANELS SHALL BE CONTROLLED VIA A SINGLE DAYLIGHT SENSOR WITHIN SPACE. REFER TO 'CRESTRON' DETAILS AND SPECIFICATIONS FOR MORE INFORMATION.

18. ALL SWITCHES, DEVICES, COVER PLATES, ETC. WITHING THIS ROOM SHALL BE BLACK.

LP-1A5

CRESTRONPANEL

LP-1A3

Z,EM

Z,EM

e,F-DAY e,F-DAY

e,F-DIM e,F-DIM

e,AA

e,AA

e,AA

e,AA

CC

c,K b,KJ g J g

a,J4EM

d,J

d,J4EM

a,J

d,J

a,J4EM

d,J

A,12

A,EM A,EM A,EM A,EM A,EM

A,12A,12

A,12

A,12 A,12A,12

A,12

A,12

A,12

A,12

A,12

A,12

A,12

C,12A,12 A,12 A,12 A,12 A,12

A,12 A,12 A,12

L1,13 L1,EM

A,12

N,15

N,EMN,EM

N,15

N,15

N,15N,15

N,15

N,15N,15

N,EMN,EM

N,15N,15

N,15

N,15

N,15

N,15

N,15

N,15

N,15

A,EM

A,EM

A,12

A,12 A,12 A,12 A,12

A,12 A,12 A,12

A,EM

A,EM

A,EM

A,EM

A,EM

A,EM

A,EM

A,EM

a,A,EM a,A,EM

A,EM A,EM

A,EM

A,EM

A,EM A,EM

A,EM

A,EM

A,EM

A,EM

A,EM

A,EM

A,EM

A,EM

A,EM

A,EM

A,EM

A,12

A,12A,12

A,12

A,12 A,12

A,12

A,12

A,12 A,12

A,12

A,12

A,EM A,12A,12 a,A a,A a,A

a,A a,A a,AA,15

A,15A,15

A,15A,15

RR,10

RR,10

RR,10

RR,10

RR,10

RR,10

R2,10

R2,10

R2,10

R2,10

S1,12 S1,12 S1,12

A,15

A,15

A,15 A,15

A,15

A,15A,15

H,15

3

F-DIM-AR,15

MM

MM

M M M

M

M

F-DIM-AR,15

F-DIM-AR,15

F-DIM-AR,15

F-DIM-AR,15

F-DIM-AR,15

F-DIM-AR,15

F-DIM-AR,15

F-DIM-AR,15

F-DIM-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

G,EM

G,EM

G,EM

G,15

G,15 G,15 G,15

G,15

G,15G,15

F-DIM-AR,15 F-DIM-AR,15

F,15F,15

M M M

BB,15

BB,15 BB,15

R2,10

R2,10

R2,10

R2,10

A,10

A,10CC1,10

CC1,10

A,10

A,10

A,10

A,10

A,10A,10

A,10A,10

A,EM A,10

A,10A,10

A,10A,10

H,10

H,10

R,EM R,EM

R1,13R,EM

R1,13R,EM

R,EM R,EM

R,EM

R,EM

F-DIM-AR,12

F-DIM-AR,12

M

A,11

A,11 A,11

A,11

A,11

A,11 A,11

A,11

A,11 A,11

A,11

A,EM A,EM A,EMA,EM

F-DIM-AR,11

F-DIM-AR,11

F-DIM-AR,11

F-DIM-AR,11

L1,11

L1,11

L1,11

M

M

A,11 A,11 A,11 A,11 A,11

A,11A,11 A,11

A,11A,11 A,11

A,11A,11

A,11A,11 A,11

A,11 A,11 A,11

A,11 A,11 A,11 A,11

C,11

c,U c,U c,U c,U,EM a,U,EM

b,U

c,U,EM c,U c,U c,U a,U

CRESTRONPANEL

LP-1A7

ELP-1A9

LP-1A8

b,K

c,K

c,K

b,U b,U b,U b,U

b,U b,U b,U b,U b,U

d,J4EM

d,J d,J a,J4EM

d,J d,J

d,J d,J

d,J d,J

CRESTRONPANEL

e,AA

C

a,J

d,J4EM

d,J

b,KJ g

S f S f

e,F-DIM

e,F-DAY

a,J4EM

d,J

a,J4EM

d,J

J g

e,AA e,AA e,AA

e,F-DIM

e,F-DAYe,F-DAY

e,F-DAYe,F-DAYe,F-DAY

C

MOTORIZED SHADECONTROL (TYPICAL)

LP-1A6

c,K

LP-1A4

e,F-DAY e,F-DAY

e,F-DIM e,F-DIM

e,AA

e,AA

e,AA

e,AA

C C

c,K b,KJ g

d,J

a,J

d,J

d,J

J f

G,14

Z,EM

Z,EM

NN,13

A,13 A,13

A,13 A,13NN,13

NN,13

R1,13

R1,13

R1,13

R1,13

A,11A,11

A,11

A,11

C,11

C,12

A,11

A,11

A,11

G,14 G,14 G,14

G,EM G,14 G,14 G,EM

G,14 G,14 G,14

F-DIM-AR,14

F-DIM-AR,14

M M

M

M

F-DIM-AR,14

F-DIM-AR,14

F-DIM-AR,14

F-DIM-AR,14

MM,14

MM,14

CRESTRONPANEL

ELP-A9

LP-1A14

CRESTRONPANEL

c,MM

c,MM

c,MM

c,MM

c,MM

MM,EM b,MM

d,TT

d,TT

d,TT

d,TT

d,TT

b,MM

b,MM

b,MM b,MM

b,MM b,MM

b,MM b,MM

b,MM a,MM

a,MM

a,MM

a,MM

a,MM

a,MM

d,R2a

d,R2a

d,R2a

G,14

M

c,MM c,MM

c,MM

c,MM

c,MM c,MM

c,MM

c,MM

c,MM

c,MM

c,MM

b,A

b,A

b,A

b,A

b,A

b,A

b,A

b,A

a,A

q,SS

a,A

b,A

b,A

b,A

b,A

b,A

b,A

b,A

b,A

a,A

p,SS

a,A

LP-1A9

ELP-A15

CRESTRONPANEL

A,12

A,EM

A,EM

A,11

DD

DD

hjkhjkh

DD

DD

hjkhjkhjkh

DD

DD

DD

hjkhjkh

DD

DD

hjkhjkhjkh

DD

DD

DD

hj

khj

kh

DD

DD

hj

khj

khj

kh

DD

DD

DD

hj

khj

kh

DD

DD

hj

khj

khj

kh

DD

DD

DD

efgefge

DD

DD

efg

efgefgeDD

DD

DDef

gef

ge

DD

DD

ef

g

ef

gef

ge

DD

DD

efge

DD

DD

efg

efgefgeDD

DD

ef

ge

DD

DD

ef

g

ef

gef

ge

DD

DD

acda

DD

DD

acdacd

acda

DD

DD

acda

DD

DD

acdacd

acda

DD

m,CC1

m,CC1

m,CC1m,CC1

m,CC1

m,CC1

m,CC1m,CC1

n,CC2

n,CC2

Z,EM

Z,EM

L1,EM

exit

exit

exit

exit

exit

exit

exit

exit

exitexit

exit

exit

exit

exit

exitexitexitexitexit

exit

exit

exit

exit

exit

exit

exit

exit

exit

exit

exit

exit

exit

exit

exit

exit

exit

exit

exit ex

it

exit

exit

BALCONY

STAIRexit

exit

exitc,b,U d,b,U

MM,EM MM,EM

MM,EM MM,EM

ELP-A8

ELP-A8

exit

a,J4EM

a,J4EM

S f S f

S f S f

e,F-DAY e,F-DAY

d,J4EM

d,J4EM

d,J4EM

REFER TONOTE #8

LECTURE101

INDICATES 'NORMAL' AND'EMERGENCY' CIRCUITFOR LIGHTING WITHINROOM. WIRE LIGHTINGTHROUGH 'CRESTRON'PANEL (TYPICAL)

d,J4EM

a,J4EM

d,J4EM

a,J4EM

d,J4EM

a,J4EM

d,J4EM

d,J4EM

a,J4EM

a,J4EM

d,J4EM

d,J4EM

d,J4EM

d,J4EM

e,F-DAY e,F-DAY

INDICATES 'NORMAL' AND'EMERGENCY' CIRCUITFOR LIGHTING WITHINROOM. WIRE LIGHTINGTHROUGH 'CRESTRON'PANEL (TYPICAL)

N,15

N,15

N,15

NN,13

NN,13

G,14

G,14

OFFICE170F

C

exit

F-DIM-AR,15 F-DIM-AR,15

F-DIM-AR,15F-DIM-AR,15

F-DAY-AR,15

MC

3

3 4

d,b,U

c,b,U d,b,Ud,b,U

PP,EM

PP,EM

PP,EM

PP,EM

PP,EM

PP,EM

MOUNTED IN FACE OFRISER (TYPICAL FOR 6)

REFER TONOTE #12

CRESTRONPANEL

LP-1A-12ELP-LA-11

C

REFER TONOTE #12

CONTROLS FLUORESCENTPORTION OF FIXTURE(TYPICAL)

CONTROLS 'MR' PORTIONOF FIXTURE - TYP.

STORAGE170M

STUDY190

STAIRS1S05

G,EM

G-DAY,15

G-DAY,15

F,15F,15

F,15F,15M

M

exit

exit

exit

exit

CRESTRONPANEL

A/V BOOTH121

A/V BOOTH121

REFER TO NOTE #18

REFER TO NOTE #18

d,R2a

MM,EMb,MM

b,MM

d,TT

c,MM

AAA,10

AAA,10

R2a,EM

R2a,EM

d,J

d,J

GENERAL LIGHTING NOTE :

Contractor shall reference the Architectural RCP drawingsfor fixture location, type, and count. Reference ElectricalLighting plans for circuiting and electrical notes.

TMGEngineeringInc.

TMG JOB NUMBER

Fax: 732-738-9672

1090 King Georges Post Rd.Suite No. 903Edison, New Jersey 08837Phone: 732-738-9670

New Jersey Certificate of AuthorizationNumber 24GA28081900

Consulting Mechanicaland Electrical Engineers

ISSUE DATE:

SHEET NUMBER:

SHEET TITLE:

Copyright (c) by Environetics, Inc. All Rights Reserved.

CHECKED BY:

DRAWN BY:

PROJECT NUMBER:

DESIGN DELIVERABLE:

REV DATE DESCRIPTION

CLIENT:

PROJECT TEAM:

SEAL

:

Structural Engineer:Environetics Design1617 JFK BLVD.,Suite 1600Philadelphia, PA 19103

Montclair, New Jersey

CLIE

NT:

Architect:Environetics Group Architects180 Sylvan Ave.Englewood Cliffs, NJ 07632

MEP Engineer:TMG Engineering Inc.1090 King Georges Post RoadSuite 903Edison, NJ 08837

Civil Engineer:Langan Engineering & Environmental Services619 River DriveCenter 1Elmwood Park, NJ 07407-1338

AV / IT / Security / Accoustical Consultant:The Sextant Group Inc.730 River AvenuePittsburgh, PASuite 600 15212

MO

NTC

LAIR

STA

TE U

NIV

ERSI

TYSC

HO

OL

OF

BUSI

NES

SM

ONT

CLAI

R, N

EW J

ERSE

Y

ADDENDUM NO. 2

06/17/13

6/14

/201

3 3:

30:0

2 PM

E-3

ELECTRICAL -FIRST FLOORLIGHTING PLAN

Mon

tcla

ir S

t ate

Uni

vers

ity

P.B.

Ken S.

10-115

Montclair StateUniversity

10-115

FRANK S. RADOSIN N.J.P.E. 33923

1/8" = 1'-0"1 ELECTRICAL - FIRST LEVEL - LIGHTING PLAN

M

M

M

M

M

M

M

M

M M

M M

M

M

M

M

M

M

M M

M

M M

MM

MM

MM

M M

M M

M M

MM

MM

MM

M

M

M

M

M

M

M

M

M

2 4 5 6 9 12 15 16 18

A

B

H

K

L

M

N

O

C

P

17

D

11 14

G

I

197 8 12.1 14.7

E

F

J

Q

3

18.9

15.1 16.2 16.9

E.1

J.9

16.110

SBUSTEACHING

LAB224

EXECUTIVEED214

IT2D01

MEN'SRESTROOM

2R02

DEANCONFERENCE

290K

STUDY289

STUDY287

STUDY285

STUDY283

STUDY281

STUDY239

STUDY237

STUDY235

STUDY231

STUDY233

SECURESTORAGE

230F

FLEXIBLESTANDARD

215

ASSOCIATEDEAN290J

ELEC.2E01

RECEPTION290

DEANOFFICE

290H

ASSOCIATEDEAN290F

ASSISTANTDEAN290E

WOMEN'SRESTROOM

2R01GRADSTUDY

255

CENTERFOR

SUSTAINABILITY250

EXECUTIVEED210

ASSOC.DIR.230C

ASSOC.DIR.230D

DIRECTOR230E

CORRIDOR2C03

DIRECTOR250A

EXECUTIVEED211

STAIRS2S03

FLEXIBLESTANDARD

220STAIRS

2S01

CORRIDOR545EEE

DEANSUITE

298

COPY/COFFEE290D

STORAGE290G

IT DEPT.230A

HELP DESK230

CORRIDOR2C03

CORRIDOR2C02

CORRIDOR2C04

CORRIDOR2C01

STUDENTWORKERS

GRAD.ASSIST.

290A

ADMIN290B

ASSISTANTDEAN290C

OFFICE230B

BREAKOUTROOM

217

SECUREFILE

STORAGE290N

ADMIN290M

ADMIN290L

HK2J01

ATRIUM100

NOTES :

1. EMERGENCY FIXTURES, TYPE 'J4' IN ROOMS 215, 220, 221, 224 AND 225 SHALL HAVE THEIR THIRD LAMP WIRED DIRECTLY TO EMERGENCY POWER CIRCUIT 'ELP-2A-2'. THE INTENT IS FOR THESE LAMPS TO BE ENERGIZED ONLY IN THE EVENT OF THE EMERGENCY GENERATOR RUNNING. PROVIDE A LINE 24 RELAY TO ENERGIZE LAMPS ONLY IN THE EVENT OF POWER LOSS.

2. POWER CIRCUITS FOR ALL LIGHTING, SHADES, SCREENS, ETC. INDICATED WITHIN ROOMS WITH CRESTRON PANELS SHALL BE CIRCUITED THROUGH CRESTRON PANEL.

3. ALL CORRIDOR LIGHTING SHALL BE CONTROLLED VIA LOCAL SWITCHES WITH OVERRIDE 'OFF' BY B.M.S. ALL STAIRWELL LIGHTING SHALL BE CONTROLLED BY B.M.S. SYSTEM PROVIDE LIGHTING RELAYS AND CONTACTORS AS REQUIRED.

4. ELECTRICAL ROOM AND AV/IT ROOM SHALL BE CONTROLLED BY LOCAL SWITCHES ONLY.

5. CONNECT DESIGNATED 'EM' CORRIDOR AND EXIT LIGHTS TO EMERGENCY CIRCUIT ELP-2A-1, UNLESS OTHERWISE NOTED. ALL EMERGENCY LIGHTING SHALL REMAIN ON (UNSWITCHED) AS NIGHT LIGHTING.

6. STAIRWELL LIGHTING SHALL BE CONNECTED TO EMERGENCY CIRCUIT ELP-A-3.

7. ALL ELECTRIC PANEL LOCATIONS ARE INDICATED ON POWER DRAWINGS.

8. ALL NORMAL POWER LIGHTING CIRCUITS INDICATED ARE IN PANEL "LP-2A", UNLESS OTHERWISE NOTED. ALL NORMAL POWER LIGHTING CIRCUITS SHALL BE WIRED THROUGH FLOOR LIGHTING RELAY PANEL AND CONTROLLED VIA 'B.M.S.' SYSTEM.

9. COORDINATE ALL FIXTURE TYPES WITH ARCHITECTURAL CEILING PLANS PRIOR TO ORDERING.

10. EMERGENCY LIGHTING WITHIN THIS SPACE SHALL BE WIRED THROUGH 'CRESTRON' PANEL WITH A PHASE LOSS SENSOR TO TURN ALL EMERGENCY FIXTURES ON TO FULL BRIGHTNESS IN THE EVENT OF POWER LOSS ON THE NORMAL AND/OR EMERGENCY CIRCUIT FOR THE SPACE.

11. ALL OCCUPANCY SENSORS, WALL MOUNTED OR CEILING MOUNTED WITH OVERRIDE SWITCH SHALL BE PROGRAMMED TO BE MANUAL ON AUTO OFF. TIME DELAY FOR UNOCCUPIED SPACE SHALL BE AS DIRECTED BY THE UNIVERSITY.

12. CONTRACTOR SHALL PROVIDE AN ALTERNATE BID TO USE A SINGLE DAYLIGHT SENSOR TIED INTO ROOM 'CRESTRON' PANEL WHERE APPLICABLE IN LIEU OF DAYLIGHT HARVESTING FIXTURES.

13. ALL 'CRESTRON' PANELS INDICATEDED IN ROOMS WITHOUT CLOSETS FOR THE PANEL SHALL BE LOCATED ABOVE DROPPED CEILING.

14. ALL OCCUPANCY SENSORS WITHIN STUDY ROOMS SHALL BE CAPABLE OF INTERFACING WITH ROOMS A/V EQUIPMENT.

15. ALL LIGHTING DESIGNATED WITH DAYLIGHT HARVESTING FEATURE WITHIN ROOMS THAT ARE BEING CONTROLLED WITH 'CRESTRON' PANELS SHALL BE CONTROLLED VIA A SINGLE DAYLIGHT SENSOR WITHIN SPACE. REFER TO 'CRESTRON' DETAILS AND SPECIFICATIONS FOR MORE INFORMATION.

M

HH,15

HH,15

HH,15

HH,15

MM,15

HH,15

HH,15

HH,15MM,15

M

M

F,15

HH,15

HH,15

HH,15

HH,15

MM,15

HH,15

HH,15

HH,15HH,15

a Mb M

a,A,15 a,A,15 a,A,15

a,A,15

a,A,15

a,A,15

a,A,15 a,A,15 a,A,15

b,NN,15 b,NN,15b,NN,15

b,NN,15

b,NN,15

b,NN,15b,NN,15

b,NN,15

F-AR,15

F-AR,EM

F-AR,EM

F-AR,EM

HH,15 HH,15

HH,15 HH,15

HH,15 HH,15

HH,15 HH,15

M

F-AR,15

F-AR,15 F-AR,15

F-AR,15F-AR,15

F-AR,15

M

F-AR,EM

F-AR,EMM

A,15

A,15

A,15

A,15

A,15

A,15

A,15

A,15M

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

M

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

33

M M M

F-DIM-AR,15 F-DIM-AR,15F-DIM-AR,15F-DIM-AR,15

G-AR,15G-AR,15G-AR,15G-AR,15

G,15 G,15G-AR,15

G-AR,15G-AR,15

G-AR,15

b,A

b,A

b,A

A,EM

A,12

A,12

A,EMA,EM

A,EM

A,EM

F-DIM-AR,15

a,b,UEM

a,b,U

c,b,U c,b,U

c,b,U c,b,U

c,b,U c,b,UEM

c,b,U c,b,U

c,b,UEM

c,b,U

CONTROLS FLUORESCENTPORTION OF FIXTURE(TYPICAL)CONTROLS 'MR'PORTION OFFIXTURE - TYP.

ELP-2A3

LP-2A16

CRESTRON PANEL

F-DIM-AR,15

F-DIM-AR,15

M M MMM

F-DIM-AR,15

F-DIM-AR,15

F-DIM-AR,15

F-DIM-AR,15

F-DIM-AR,15

F-DIM-AR,15

F-DIM-AR,15

A,12A,12A,12A,12

A,12A,12

A,12

A,12A,12

A,12 A,12

A,12A,12

A,12

CRESTRONPANEL

Cd,K e,K

J g

S f

i,F-DIM

i,F-DAY

a,WEM

b,W

J h

i,F-DAY

i,F-DAYi,F-DAYi,F-DAY

C

MOTORIZED SHADECONTROL (TYPICAL)

MOTORIZED SCREENCONTROL (TYPICAL)

ELP-2A3

LP-2A6

S f

S f

S f

J e

b,W

b,WEM

i,F-DIM

i,F-DAY

c,AA c,AA

S f S f S f

F-DAY,12

A,EM

A,EM

A,EMC,12 A,12A,12

A,12

A,12 A,12

A,12 A,12A,12

A,12

A,12

A,12

A,12

A,12

A,12

A,12 A,12

A,12A,12A,12A,12

Z,EM

Z,EM

CRESTRONPANEL

C

d,K e,K

J g

S f

J h

C

MOTORIZED SHADECONTROL (TYPICAL)

S f S f S f

c,AA c,AA c,AAc,AA

J d

MOTORIZED SCREENCONTROL (TYPICAL)

CRESTRONPANEL FORROOM 215

LP-2A8

S e

S e

c,K1

c,K1

c,K1

a,J4,EMb,Jb,Jb,Jb,J4,EM

a,Jb,J

b,J

b,J

a,J

b,J

b,Jb,J

b,Jb,Jb,J

d,W

c,AA c,AA c,AA c,AA

i,F-DIM

i,F-DAY

i,F-DAY

i,F-DAYi,F-DAYi,F-DAY

i,F-DIM

i,F-DAY

b,K e,K

h,F-DIM

J g J f

h,F-DIM

h,F-DIM

h,F-DIM

h,F-DIMh,F-DIMh,F-DIMh,F-DIM

e,K1

e,K1

e,K1

a,W

b,W

b,W

b,W

a,WEM

b,W

b,W

b,WEM

b,W

b,W

a,W

b,W

b,W

b,W

b,W

b,W

d,W

a,W

d,W

d,W

d,W

d,W

d,W

d,K1c,K1

a,J4EM

b,J

b,J

b,J4EM

a,J

b,J

b,J4EM

b,J

a,J4EM

b,J

b,J

b,J4EM

S f

S f

CRESTRONPANEL FORROOM #225

LP-2A7

LP-2A5

CRESTRONPANEL FORROOM 224

h,F-DIM

h,F-DAY

h,F-DAY

h,F-DIM

h,F-DAY

h,F-DAY

a,J4EM

b,J

b,J4EM

b,J

a,J

b,J

b,J

b,J

b,J

a,J4EM

b,J

b,J4EM

b,J

c,K d,K

J e J f

S g S g S g S g

LP-2A3

h,F-DIM

h,F-DAY

h,F-DAY

h,F-DIM

h,F-DAY

h,F-DAY

a,J

b,J

b,J

b,J

b,J

c,K d,K

J e J f

S g S g S g S g

Z,EM

Z,EM

CRESTRONPANEL

LP-2A9

d,J

a,J4EM

b,K

J d

A,EM

A,EM

A,EM

A,EM

A,EM

A,EM

A,EM

JJ,EM

JJ,EM

F-DAY,11

A,11

A,11 A,11

A,11

A,11

A,11 A,11

A,11

A,11

A,11

A,11 A,11

A,11

A,11 A,11

A,11

A,11

A,11

A,11C,11

A,11

A,11

A,11

A,11 A,11

A,11

A,11 A,11

A,11 A,11 A,11 A,11 A,11

A,11

A,11

A,11

A,11

A,EM A,EM A,EM

A,EM

A,11 A,11

A,11

A,11A,11

A,11A,11

A,11 A,11

R1,11

R1,11

L1,EM

L1,EM

N,12 N,12

N,EM

N,12

N,12

N,12

N,11

N,11

N,EM

N,11

N,11

N,EM

N,11

N,11

N,11

N,11

N,11

N,11

N,11

N,11

N,11

N,EM

N,EM

N,11

N,11

N,11

ML1,11

P4,13 P4,13 P4,13 P4,13 P4,13 P4,13

P4,13 P4,13 P4,13 P4,13 P4,13 P4,13

P5,13 P5,13 P5,13 P5,13 P5,13 P5,13 P5,13

P5,13 P5,13 P5,13 P5,13 P5,13 P5,13 P5,13

GG,13

GG,13

GG,13

GG,13

GG,13

GG,13

GG,13

GG,13

GG,13

A,13

A,13

A,13

A,13

A,13

A,13

A,13

A,13

A,13 A,13 A,13

A,13 A,13 A,13

A,13 A,13 A,13

A,13 A,13 A,13

A,13 A,13 A,13

A,EM A,13 A,13 A,13

A,13 A,13

A,13A,13

A,13

A,13 A,13

A,13

H,13

H,13

H,13

F-DAY-AR,14

F-DAY-AR,14F-DAY-AR,14

F-DAY-AR,14F-DAY-AR,14

F-DAY-AR,14F-DIM-AR,14

F-DIM-AR,14

M

Z,EM

Z,EM

F-DAY-AR,14F-DAY-AR,14

F-DAY-AR,14 F-DAY-AR,14F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

G,14

G,14G,14

G,14

M

MMM

G,EM

G,14G,14G,14

G,14

G,14

G,14

G,EM

G,EM

G,EM

G,14

G,14

G,14

G,14

F-DIM-AR,14

F-DIM-AR,14

F-DIM-AR,14

F-DIM-AR,14

F-DIM-AR,14

F-DIM-AR,14

F-DIM-AR,14

F-DIM-AR,14

F-DIM-AR,14

F-DIM-AR,14

MMM MM

exit

exit

A,12

exit

c,AAc,AA

exitexit

exit

exit

exit

exitexit

exit

exit exit

exitexit

exit

exit

exit

exit

exitexit

exit exit exit

exit

exit

exit

exit

exit

exit

ELP-2A2

A,EM

ELP-2A2

A,EM

ELP-2A2A,EM

ELP-2A2

A,EM

ELP-2A2 A,EM

ELP-2A2

A,EM

ELP-2A2

A,EM

ELP-2A2

STAIR

ELP-2A2

ELP-2A2

exit

ELP-2A2

ELP-2A2

ELP-2A3

LP-2A6

INDICATES 'NORMAL' AND'EMERGENCY' CIRCUITFOR LIGHTING WITHINROOM. WIRE LIGHTINGTHROUGH 'CRESTRON'PANEL (TYPICAL)

a,WEM

b,WEM

a,WEM

b,WEM

INDICATES 'NORMAL' AND'EMERGENCY' CIRCUITFOR LIGHTING WITHINROOM. WIRE LIGHTINGTHROUGH 'CRESTRON'PANEL (TYPICAL)

CRESTRONPANEL

ELP-2A3

LP-2A10 INDICATES 'NORMAL' AND 'EMERGENCY'

CIRCUIT FOR LIGHTING WITHIN ROOM.WIRE LIGHTING THROUGH 'CRESTRON'PANEL (TYPICAL)

d,WEM

a,WEM

a,WEM

b,WEM

a,J4,EMb,J4,EM

b,J4,EM

b,J4,EM

b,J4EM

b,J4EM

a,J4EM

b,J

b,J4EM

b,J

b,J4EM

a,J4EM

b,J

b,J4EM

b,J

b,J4EM

A,11

A,11

A,11

b,NN,15

c M

c,KK1,15

CC C C

F-DAY-AR,14

F-DAY-AR,14F-DIM-AR,14

F-DIM-AR,14

c,K

d,J

d,J

a,J4EM

d,Jd,J

d,JEM

a,J

d,J

e,AA

e,AA

e,AA

e,AA

e,F-DIM

e,F-DIM

e,F-DIM e,F-DIM

e,F-DIM

e,F-DIM

C C CC

3

4

3

4

F-DAY,12

F-DAY,11

A,11

A,11

REFER TONOTE #10

REFER TONOTE #10

REFER TONOTE #10

REFER TONOTE #10

TUTORINGOPEN LAB

225

UCLASSROOM

221

CORRIDOR2C05

BREAKOUTROOM

227

exit

exit

exit

INDICATES 'NORMAL' AND'EMERGENCY' CIRCUITFOR LIGHTING WITHINROOM. WIRE LIGHTINGTHROUGH 'CRESTRON'PANEL (TYPICAL)

CRESTRONPANEL FORROOM 220

GENERAL LIGHTING NOTE :

Contractor shall reference the Architectural RCP drawingsfor fixture location, type, and count. Reference ElectricalLighting plans for circuiting and electrical notes.

TMGEngineeringInc.

TMG JOB NUMBER

Fax: 732-738-9672

1090 King Georges Post Rd.Suite No. 903Edison, New Jersey 08837Phone: 732-738-9670

New Jersey Certificate of AuthorizationNumber 24GA28081900

Consulting Mechanicaland Electrical Engineers

ISSUE DATE:

SHEET NUMBER:

SHEET TITLE:

Copyright (c) by Environetics, Inc. All Rights Reserved.

CHECKED BY:

DRAWN BY:

PROJECT NUMBER:

DESIGN DELIVERABLE:

REV DATE DESCRIPTION

CLIENT:

PROJECT TEAM:

SEAL

:

Structural Engineer:Environetics Design1617 JFK BLVD.,Suite 1600Philadelphia, PA 19103

Montclair, New Jersey

CLIE

NT:

Architect:Environetics Group Architects180 Sylvan Ave.Englewood Cliffs, NJ 07632

MEP Engineer:TMG Engineering Inc.1090 King Georges Post RoadSuite 903Edison, NJ 08837

Civil Engineer:Langan Engineering & Environmental Services619 River DriveCenter 1Elmwood Park, NJ 07407-1338

AV / IT / Security / Accoustical Consultant:The Sextant Group Inc.730 River AvenuePittsburgh, PASuite 600 15212

MO

NTC

LAIR

STA

TE U

NIV

ERSI

TYSC

HO

OL

OF

BUSI

NES

SM

ONT

CLAI

R, N

EW J

ERSE

Y

ADDENDUM NO. 2

06/17/13

6/14

/201

3 3:

30:2

0 PM

E-4

ELECTRICAL -SECOND FLOORLIGHTING PLAN

Mon

tcla

ir S

t ate

Uni

vers

ity

P.B.

Ken S.

10-115

Montclair StateUniversity

10-115

FRANK S. RADOSIN N.J.P.E. 33923

1/8" = 1'-0"1 ELECTRICAL - SECOND LEVEL - LIGHTING PLAN

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

MM

MM

M

MM

M M

MM

M M

M M

MM

M

M

M

1 2 4 5 6 9 12 15 16 18

A

B

H

K

L

M

N

O

C

P

17

D

11 14

G

I

197 8 12.1 14.7

E

F

J

Q

3

18.9

15.1 16.2 16.9

E.1

J.9

16.110

STAFFLOUNGE

325

OFFICE371

OFFICE367

OFFICE369

OFFICE375

OFFICE374

OFFICE376

OFFICE368

OFFICE378

OFFICE364

OFFICE352

OFFICE354

OFFICE356

OFFICE358

OFFICE362

OFFICE360

OFFICE363

OFFICE337

STUDY331

OFFICE348

OFFICE373

OFFICE372

OFFICE350

OFFICE342

OFFICE351

OFFICE339

UCLASSROOM

314

GRADUATEASSISTANT

388

STORAGE392B

STUDY389

OFFICE387

OFFICE385

OFFICE383

OFFICE381

OFFICE366

OFFICE370

IT3D01

OFFICE361

OFFICE353

CCLASSROOM

315

VIDEOPRODUCTION

345

OFFICE346

CCLASSROOM

310

MEDIUMCONF.

380

STAIRS3S03

STAIRS3S01

CORRIDOR3C07

CORRIDOR3C05

CORRIDOR3C03

CORRIDOR3C02

CORRIDOR3C04

CORRIDOR3C08

BREAKOUTROOM

317

UCLASSROOM

324

OFFICE330A

MEN'SRESTROOM

3R02

CORRIDOR3C06

ELEC3E01

WOMEN'SRESTROOM

3R01

HK3J01

SEMINAR327

FHTCLASSROOM

321

FHTCLASSROOM

311

CCLASSROOM

320

GRADUATESERVICES

330

COPY/MAIL390

CORRIDOR3C01

NOTES :

1. EMERGENCY FIXTURES, TYPE 'J4' IN ROOMS 310, 311, 314, 315, 320, 321, AND 324 SHALL HAVE THEIR THIRD LAMP WIRED DIRECTLY TO EMERGENCY POWER CIRCUIT 'ELP-2A-4'. THE INTENT IS FOR THESE LAMPS TO BE ENERGIZED ONLY IN THE EVENT OF THE EMERGENCY GENERATOR RUNNING. PROVIDE A LINE 24 RELAY TO ENERGIZE LAMPS ONLY IN THE EVENT OF POWER LOSS.

2. POWER CIRCUITS FOR ALL LIGHTING, SHADES, SCREENS, ETC. INDICATED WITHIN ROOMS WITH CRESTRON PANELS SHALL BE CIRCUITED THROUGH CRESTRON PANEL.

3. ALL CORRIDOR LIGHTING SHALL BE CONTROLLED VIA LOCAL SWITCHES WITH OVERRIDE 'OFF' BY B.M.S. ALL STAIRWELL LIGHTING SHALL BE CONTROLLED BY B.M.S. SYSTEM PROVIDE LIGHTING RELAYS AND CONTACTORS AS REQUIRED.

4. ELECTRICAL ROOM AND AV/IT ROOM SHALL BE CONTROLLED BY LOCAL SWITCHES ONLY.

5. CONNECT DESIGNATED 'EM' CORRIDOR, EXIT AND ROOM LIGHTS TO EMERGENCY CIRCUIT ELP-2A-3. ALL EMERGENCY LIGHTING SHALL REMAIN ON (UNSWITCHED) AS NIGHT LIGHTING.

6. STAIRWELL LIGHTING SHALL BE CONNECTED TO EMERGENCY CIRCUIT ELP-A-3.

7. ALL ELECTRIC PANEL LOCATIONS ARE INDICATED ON POWER DRAWINGS.

8. ALL NORMAL POWER LIGHTING CIRCUITS INDICATED ARE IN PANEL "LP-3A", UNLESS OTHERWISE NOTED. ALL NORMAL POWER LIGHTING CIRCUITS SHALL BE WIRED THROUGH FLOOR LIGHTING RELAY PANEL AND CONTROLLED VIA 'B.M.S.' SYSTEM.

9. COORDINATE ALL FIXTURE TYPES WITH ARCHITECTURAL CEILING PLANS PRIOR TO ORDERING.

10. EMERGENCY LIGHTING WITHIN THIS SPACE SHALL BE WIRED THROUGH 'CRESTRON' PANEL WITH A PHASE LOSS SENSOR TO TURN ALL EMERGENCY FIXTURES ON TO FULL BRIGHTNESS IN THE EVENT OF POWER LOSS ON THE NORMAL AND/OR EMERGENCY CIRCUIT FOR THE SPACE.

11. ALL OCCUPANCY SENSORS, WALL MOUNTED OR CEILING MOUNTED WITH OVERRIDE SWITCH SHALL BE PROGRAMMED TO BE MANUAL ON AUTO OFF. TIME DELAY FOR UNOCCUPIED SPACE SHALL BE AS DIRECTED BY THE UNIVERSITY.

12. CONTRACTOR SHALL PROVIDE AN ALTERNATE BID TO USE A SINGLE DAYLIGHT SENSOR TIED INTO ROOM 'CRESTRON' PANEL WHERE APPLICABLE IN LIEU OF DAYLIGHT HARVESTING FIXTURES.

13. ALL 'CRESTRON' PANELS INDICATEDED IN ROOMS WITHOUT CLOSETS FOR THE PANEL SHALL BE LOCATED ABOVE DROPPED CEILING.

14. ALL OCCUPANCY SENSORS WITHIN STUDY ROOMS SHALL BE CAPABLE OF INTERFACING WITH ROOMS A/V EQUIPMENT.

15. ALL LIGHTING DESIGNATED WITH DAYLIGHT HARVESTING FEATURE WITHIN ROOMS THAT ARE BEING CONTROLLED WITH 'CRESTRON' PANELS SHALL BE CONTROLLED VIA A SINGLE DAYLIGHT SENSOR WITHIN SPACE. REFER TO 'CRESTRON' DETAILS AND SPECIFICATIONS FOR MORE INFORMATION.

CRESTRONPANEL

e,AA

C

a,J

d,J

c,K b,K

S f S f

e,F-DIM

e,F-DAY

J g

e,AA e,AA e,AA

e,F-DIM

e,F-DAYe,F-DAY

e,F-DAYe,F-DAYe,F-DAY

C

MOTORIZED SHADECONTROL (TYPICAL)

MOTORIZED SCREENCONTROL (TYPICAL)

LP-3A4

J h

d,Jd,J

Z,EM

Z,EM

S fS f S f S f S f S f

e,F-DAY e,F-DAY

e,F-DIM e,F-DIM

a,J4EM

d,J

a,J

d,J4EM

d,J

a,J4EM

d,J

e,AAe,AA

e,AAe,AA

CC

c,K b,KJ gJ h

CRESTRONPANEL

LP-3A10

e,AA

C

a,J

d,J4EM

d,J

c,K b,K

S f S f

e,F-DIM

e,F-DAY

e,AA e,AA e,AA

e,F-DIM

e,F-DAYe,F-DAY

e,F-DAYe,F-DAYe,F-DAY

C

MOTORIZED SCREENCONTROL (TYPICAL)

a,J4EM

d,J

a,J4EM

d,J

d,J4EM

Z,EM

Z,EM

S fS f S f S f S f S f

e,F-DAY e,F-DAY

e,F-DIM

a,J4,EM

d,J

d,J4EM

a,J

d,J

d,J

e,AAe,AA

e,AAe,AA

C C

c,K b,K

CRESTRONPANEL

LP-3A7

CRESTRONPANEL

LP-3A3

J gJ h J gJ h

LP-3A6

S f

S f

S f

e,AA

a,J4,EMd,Jd,Jd,J4,EM

a,Jd,Jd,J

e,AAe,AA

e,AAe,AAe,AA

e,F-DIM

e,F-DIM

e,F-DAY

e,F-DAY

e,F-DAY

e,F-DAY

b,K

c,K

J h

J g

C

C

F-DAY-AR,11 F,11 F,EM F,11

A,11 A,11

A,11

A,11 A,EM

A,11C,11

F,EM

F,EM

F,EM

F,EM F,EM

F,EM

F,EM

F,EM

F,EM

F,EMF,EMF,EM

F,EM

F,EM

F,EMF,EMF,EM

A,11

A,11 A,11C,11

F,11 F,11 F,11

F,11

F,11 F,11 F,11 F,11

F,11

F,11

F,11

F,11

F,11

F,11

F,11

F,11

F,11

F,11

F,11

F,11F,11F,11F,11

F,11

F,11

F,11

F,11 F,11F,11

A,11 A,11

A,11A,11

A,11

A,11

A,11

A,11 A,11

A,11 A,11

A,11

A,11

A,11

A,EM

A,11A,11A,11

JJ,EM

A,EM

A,11A,11A,11

JJ,EM

A,11

R1,11

R1,11a,J4EM

d,J

d,J

a,J

d,J

d,J

a,J

d,J

d,J

b,K c,K b,K

J e

LP-3A8

LP-3A5

CRESTRONPANEL

ROOM 321

a,J4EM

d,J

d,J

d,J4EM

a,J4,EMd,Jd,Jd,Jd,J

a,Jd,Jd,Jd,Jd,Jd,Jd,J

a,J4,EMd,Jd,Jd,Jd,J

a,Jd,Jd,J

b,K1

c,K1

b,K1

J e

A,11 A,11A,11

e,F

e,F

CRESTRONPANEL

ELP-2A5

LP-3A9 G,EM

M

S e

a,U,EMb,U

a,Ub,U

b,Uc,U

b,Uc,U

b,Uc,U

b,Uc,U

b,Uc,U,EM

b,Uc,U

S e

J d

N,9

N,9

N,EM

N,9

N,9

N,9

L1,EM

L1,EM

N,9

N,9

N,9

N,9

N,9

N,EM

N,9

N,9

N,9

N,9

N,9

N,EM

N,9

N,9

N,9

N,9

N,9

N,9

L1,9 M

F-DAY-AR,12

F-DAY-AR,12 F-DAY-AR,12

F-DAY-AR,12

M

M

M

M

MM

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12 F-DAY-AR,12

F-DIM-AR,12

F-DIM-AR,12

MM

F-DIM-AR,12

F-DIM-AR,12

F-DIM-AR,12

F-DIM-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DIM-AR,12

F-DIM-AR,12 M

M CMM

G,12

G-DAY,12

G-DAY,12

G,12

G,12

MM

MM

M

M

F-DAY-AR,12 F-DAY-AR,12

F-DAY-AR,12 F-DAY-AR,12

G,12F-DIM-AR,12

F-DIM-AR,12

F-DIM-AR,12

F-DIM-AR,12

CRESTRONPANEL

ELP-2A5

LP-3A12

a,U,EMb,U

a,Ub,U

b,Uc,U

b,Uc,U

b,Uc,U

b,Uc,U

b,Uc,U,EM

b,Uc,U

M

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

M M M M

M

M

M

MM

M

F-DAY-AR,13

F-DAY-AR,13

MM

MM

MM

MM

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DIM-AR,13

F-DIM-AR,13

F-DIM-AR,13

F-DIM-AR,13

F-DIM-AR,13

F-DIM-AR,13

MMM

M M M M M

M

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DIM-AR,13

F-DAY-AR,13

F-DAY-AR,13

G,13

G,EM

G,13

M

exit

exit

exit

exit exit exit

exit

exitexit

exitexit

exit

exitexit

exitexitexit

exit

exit

exit exit

exit

exit

exit

exit

exit

Z,EM

Z,EM

ELP-2A4

ELP-2A4

ELP-2A4

G,EM

ELP-2A4

ELP-2A4

d,J4EM

d,J4EM

d,J4EM

e,F-DAY e,F-DAY

a,J4EM

a,J4EM

d,J4EM

d,J4EM

d,J4EM

d,J4EM

d,J4EM

d,J4EM

d,J4,EM d,J4,EM

a,J4,EMd,Jd,Jd,J4,EM

d,J4,EM d,J4,EM

d,J4,EMd,J4,EM

d,J4,EM d,J4,EM

INDICATES 'NORMAL' AND'EMERGENCY' CIRCUITFOR LIGHTING WITHINROOM. WIRE LIGHTINGTHROUGH 'CRESTRON'PANEL (TYPICAL)

d,J4EM

e,F-DAY e,F-DAY

a,J4,EM

d,J4EM

d,J4EM

d,J4EM

e,F-DIM

INDICATES 'NORMAL' AND'EMERGENCY' CIRCUIT FORLIGHTING WITHIN ROOM.WIRE LIGHTING THROUGH'CRESTRON' PANEL(TYPICAL)

N,9

ACCOUNTING392

CHAIR392A

ACCOUNTINGLAB384

ADJUNCTHOTEL

386

OFFICE355

OFFICE357

OFFICE359

OFFICE349

CENTERFOR INTER.BUSINESS

336DIRECTOR

336A

DIRECTOR330C

STORAGE330D

OFFICE330B

MM

F-DAY-AR,13 F-DAY-AR,13

F-DAY-AR,13 F-DAY-AR,13

F-DAY-AR,13 F-DAY-AR,13

G,13

G,13

M

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

G,EM

G,13

ELP-2A4

G,13

G,13

F-DAY-AR,13 F-DAY-AR,13

M

F-DAY-AR,13 F-DAY-AR,13

exit

F-DAY-AR,13

F-DAY-AR,13

M

F-DIM-AR,13

?,13

?,13

C

F-DAY-AR,12F-DAY-AR,12

F-DAY-AR,12F-DAY-AR,12

F-AR,12F-AR,12

A,11

A,11

3

4

3

OFFICE347

4

A,11

A,11

A,11

A,11

A,11

A,11

A,11CONTROLSFLUORESCENTPORTION OFFIXTURE(TYPICAL)

CONTROLS 'MR' PORTIONOF FIXTURE - TYP.

REFER TONOTE #10

REFER TONOTE #10

CONTROLS FLUORESCENTPORTION OF FIXTURE(TYPICAL)CONTROLS 'MR' PORTIONOF FIXTURE - TYP.

C

C

exit

exit

CRESTRONPANEL

ROOM 311

d,J

d,J

GENERAL LIGHTING NOTE :

Contractor shall reference the Architectural RCP drawingsfor fixture location, type, and count. Reference ElectricalLighting plans for circuiting and electrical notes.

TMGEngineeringInc.

TMG JOB NUMBER

Fax: 732-738-9672

1090 King Georges Post Rd.Suite No. 903Edison, New Jersey 08837Phone: 732-738-9670

New Jersey Certificate of AuthorizationNumber 24GA28081900

Consulting Mechanicaland Electrical Engineers

ISSUE DATE:

SHEET NUMBER:

SHEET TITLE:

Copyright (c) by Environetics, Inc. All Rights Reserved.

CHECKED BY:

DRAWN BY:

PROJECT NUMBER:

DESIGN DELIVERABLE:

REV DATE DESCRIPTION

CLIENT:

PROJECT TEAM:

SEAL

:

Structural Engineer:Environetics Design1617 JFK BLVD.,Suite 1600Philadelphia, PA 19103

Montclair, New Jersey

CLIE

NT:

Architect:Environetics Group Architects180 Sylvan Ave.Englewood Cliffs, NJ 07632

MEP Engineer:TMG Engineering Inc.1090 King Georges Post RoadSuite 903Edison, NJ 08837

Civil Engineer:Langan Engineering & Environmental Services619 River DriveCenter 1Elmwood Park, NJ 07407-1338

AV / IT / Security / Accoustical Consultant:The Sextant Group Inc.730 River AvenuePittsburgh, PASuite 600 15212

MO

NTC

LAIR

STA

TE U

NIV

ERSI

TYSC

HO

OL

OF

BUSI

NES

SM

ONT

CLAI

R, N

EW J

ERSE

Y

ADDENDUM NO. 2

06/17/13

6/14

/201

3 3:

30:3

2 PM

E-5

ELECTRICAL -THIRD FLOORLIGHTING PLAN

Mon

tcla

ir S

t ate

Uni

vers

ity

P.B.

Ken S.

10-115

Montclair StateUniversity

10-115

FRANK S. RADOSIN N.J.P.E. 33923

1/8" = 1'-0"1 ELECTRICAL - THIRD LEVEL - LIGHTING PLAN

M

M

M

M

M

M

M

M

M M

MM

M M

MM

M M

M

2 4 5 6 9 12 15 16 18

A

B

H

K

L

M

N

O

C

17

D

11 14

G

I

197 8 12.1 14.7

E

F

J

3

18.9

E.1

J.9

16.110

OFFICE441

OFFICE439

OFFICE437

OFFICE437

OFFICE431

OFFICE437

OFFICE484

OFFICE482

OFFICE467

OFFICE470

OFFICE468

OFFICE486

OFFICE483

OFFICE485

OFFICE489

OFFICE487

OFFICE463

OFFICE464

OFFICE462

OFFICE460

OFFICE458

OFFICE456

OFFICE453

OFFICE454

OFFICE450

OFFICE448

OFFICE449

OFFICE440

ADJUNCTHOTEL

438

GRADASSISTANT

434

CCLASSROOM

422

IT4D01

OFFICE466

OFFICE461

WOMEN'SRESTROOM

4R01

SEMINAR412

OFFICE447

OFFICE446

OFFICE459

OFFICE455

OFFICE457

CORRIDOR4C06

CORRIDOR4C05

CORRIDOR4C02

CORRIDOR4C04

CORRIDOR4C01

CHAIR430A

OFFICE452

STAIRS4S03

STAIRS4S01

CHAIR492A

FLEXIBLESTANDARD

421

FLEXIBLESTANDARD

411

CORRIDOR4C07

MEN'SRESTROOM

4R02

OFFICE480

OFFICE469

ADJUNCT408

COPY/MAIL494

ELEC4E01

MANAGEMENT430

STORAGE430B

NOTES :

1. EMERGENCY FIXTURES, TYPE 'J4' IN ROOMS 422, 411, AND 421 SHALL HAVE THEIR THIRD LAMP WIRED DIRECTLY TO EMERGENCY POWER CIRCUIT 'ELP-4A-3'. THE INTENT IS FOR THESE LAMPS TO BE ENERGIZED ONLY IN THE EVENT OF THE EMERGENCY GENERATOR RUNNING. PROVIDE A LINE 24 RELAY TO ENERGIZE LAMPS ONLY IN THE EVENT OF POWER LOSS.

2. POWER CIRCUITS FOR ALL LIGHTING, SHADES, SCREENS, ETC. INDICATED WITHIN ROOMS WITH CRESTRON PANELS SHALL BE CIRCUITED THROUGH CRESTRON PANEL.

3. ALL CORRIDOR LIGHTING SHALL BE CONTROLLED VIA LOCAL SWITCHES WITH OVERRIDE 'OFF' BY B.M.S. ALL STAIRWELL LIGHTING SHALL BE CONTROLLED BY B.M.S. SYSTEM PROVIDE LIGHTING RELAYS AND CONTACTORS AS REQUIRED.

4. ELECTRICAL ROOM AND AV/IT ROOM SHALL BE CONTROLLED BY LOCAL SWITCHES ONLY.

5. CONNECT DESIGNATED 'EM' CORRIDOR, EXIT AND ROOM LIGHTS TO EMERGENCY PANEL ELP-4A-1, UNLESS OTHERWISE NOTED. ALL EMERGENCY LIGHTING SHALL REMAIN ON (UNSWITCHED) AS NIGHT LIGHTING.

6. STAIRWELL LIGHTING SHALL BE CONNECTED TO EMERGENCY CIRCUIT ELP-A-3.

7. ALL ELECTRIC PANEL LOCATIONS ARE INDICATED ON POWER DRAWINGS.

8. ALL NORMAL POWER LIGHTING CIRCUITS INDICATED ARE IN CIRCUIT "LP-3A", UNLESS OTHERWISE NOTED. ALL NORMAL POWER LIGHTING CIRCUITS SHALL BE WIRED THROUGH FLOOR LIGHTING RELAY PANEL AND CONTROLLED VIA 'B.M.S.' SYSTEM.

9. COORDINATE ALL FIXTURE TYPES WITH ARCHITECTURAL CEILING PLANS PRIOR TO ORDERING.

10. EMERGENCY LIGHTING WITHIN THIS SPACE SHALL BE WIRED THROUGH 'CRESTRON' PANEL WITH A PHASE LOSS SENSOR TO TURN ALL EMERGENCY FIXTURES ON TO FULL BRIGHTNESS IN THE EVENT OF POWER LOSS ON THE NORMAL AND/OR EMERGENCY CIRCUIT FOR THE SPACE.

11. ALL OCCUPANCY SENSORS, WALL MOUNTED OR CEILING MOUNTED WITH OVERRIDE SWITCH SHALL BE PROGRAMMED TO BE MANUAL ON AUTO OFF. TIME DELAY FOR UNOCCUPIED SPACE SHALL BE AS DIRECTED BY THE UNIVERSITY.

12. CONTRACTOR SHALL PROVIDE AN ALTERNATE BID TO USE A SINGLE DAYLIGHT SENSOR TIED INTO ROOM 'CRESTRON' PANEL WHERE APPLICABLE IN LIEU OF DAYLIGHT HARVESTING FIXTURES.

13. ALL 'CRESTRON' PANELS INDICATEDED IN ROOMS WITHOUT CLOSETS FOR THE PANEL SHALL BE LOCATED ABOVE DROPPED CEILING.

14. ALL OCCUPANCY SENSORS WITHIN STUDY ROOMS SHALL BE CAPABLE OF INTERFACING WITH ROOMS A/V EQUIPMENT.

15. ALL LIGHTING DESIGNATED WITH DAYLIGHT HARVESTING FEATURE WITHIN ROOMS THAT ARE BEING CONTROLLED WITH 'CRESTRON' PANELS SHALL BE CONTROLLED VIA A SINGLE DAYLIGHT SENSOR WITHIN SPACE. REFER TO 'CRESTRON' DETAILS AND SPECIFICATIONS FOR MORE INFORMATION.

16. ALL LIGHTING ON OUTDOOR TERRACE SHALL BE CONTROLLED VIA PHOTO CELL AND BUILDING B.M.S. SYSTEM.

Z,EM

Z,EM

a,U,EMb,U

a,Ub,U

a,Ub,U

a,Ub,U

a,Ub,U

a,Ub,U

a,Ub,U

a,Ub,U

a,Ub,U

a,U,EMb,U

S c

MOTORIZED SHADECONTROL (TYPICAL)

S c

ELP-4A2

LP-4A8

CRESTRONPANEL

M M

M M M MG,13 F-DIM-AR,13

F-DIM-AR,13

G,EM

G-AR,13

G-AR,13

G-DAY-AR,13

G-DA

Y-AR

,13

G-AR,EM

F-DIM-AR,13F-DIM-AR,13

F-DAY,13

F-DAY,13

M F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,13

MM

M

F-DIM-AR,13

F-DIM-AR,13

F-DAY-AR,13

F-DAY-AR,13

F-DAY-AR,14

F-DAY-AR,14

MM

MM

MM

MM

MM

MM

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F,11

A,11

A,EM A,11

A,11

A,11C,11

F,11 F,EM F,11

F,EM

F,EM

F,EM F,EM

F,EM

F,EM

F,EM

F,EM

F,EM

F,EMF,EM

F,EM

F,EM

F,EMA,EM A,11

A,11A,11

C,11

A,11

F,11

F,11

F,11F,11 F,11 F,11

F,11

F,11

F,11

F,11

F,11

F,11F,11

F,11

F,11

F,11

F,11

F,11

F,11

F,11F,11F,11

A,11

A,11

A,11 A,11

A,11

A,11

JJ,EM

JJ,EM

A,EM

A,EM

A,11

A,11

A,11 A,11

A,11A,11

A,11

A,11

M M M M M

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DIM-AR,14

F-DIM-AR,14

MM

MM

MM

MMMMMM

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DIM-AR,14

F-DIM-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

M

F-DIM-AR,12

F-DIM-AR,12

F-DIM-AR,12

F-DIM-AR,12

M

Z,EM

Z,EM

M

F-DAY-AR,12

F-DAY-AR,12

MMM

M

F-DAY-AR,12

F-DAY-AR,12

G-DAY-AR,12G-DAY-AR,12

G-DAY-AR,12

M

F-DAY-AR,12F-DAY-AR,12

F-DAY-AR,12

F-DAY-AR,12

G-AR,12

G-AR,EM

G-DAY-AR,12

S c

MOTORIZED SHADECONTROL (TYPICAL)

S c LP-4A7

CRESTRONPANEL

Z,EM

Z,EM

R1,11

R1,11

L1,EM

L1,EM

L1,EM MN,12

N,12

N,12

N,EM

N,12

N,12

N,12

N,12

N,12

N,12

N,EM

N,12

N,12

N,12

N,12

N,12

N,12

N,12

N,EM

N,12

N,12

N,12

N,12

N,12

N,12

a,J4EMS e

MOTORIZED SHADECONTROL (TYPICAL)

S e

b,J

b,J

b,J4EM

b,J

a,J

b,J

b,J

a,J

b,J

b,J

a,J4EM

b,J

b,J

b,J

c,K

MOTORIZED SCREENCONTROL (TYPICAL)

J d

LP-4A10

CRESTRONPANEL

S e

MOTORIZED SHADECONTROL (TYPICAL)

S e

b,J

b,J

b,J

a,J

b,J

b,J

a,J

b,J

b,J

b,J

b,J

b,J

c,K

MOTORIZED SCREENCONTROL (TYPICAL)

LP-4A9

CRESTRONPANEL

J d

R2,15

R2,15

R2,15

R2,15

CONTROLS FLUORESCENTPORTION OF FIXTURE(TYPICAL)

CONTROLS 'MR' PORTIONOF FIXTURE - TYP.

exit

exit

exit

exit exit

exitexit

exit

exitexit

exitexit

exit

exit

exit

exit

exit

ELP-4A2

ELP-4A2

ELP-4A2

HK4J01

CORRIDOR4C03

ELP-4A2

STAIR

INDICATES 'NORMAL' AND'EMERGENCY' CIRCUITFOR LIGHTING WITHINROOM. WIRE LIGHTINGTHROUGH 'CRESTRON'PANEL (TYPICAL)

b,J4EM

b,J4EM

b,J4EM

b,J4EM

b,J4EM

a,J4EM

a,J4EM

b,J4EM

b,J4EM

b,J4EM

b,J4EM

b,J4EM

b,J4EM

A,11

A,11

A,11

R2,15

GRAD.ASSISTANT

410

INFO ANDOPERATIONS

492

INFOSYSTEMS

LAB488

OFFICE481

COPY/MAIL432

G,13

G,13

F-DAY,13

F-DAY,13

G-DAY-AR,13

A,11

A,11

G-AR,12

G-DAY-AR,12

G-AR,12

A,11

e,F-DAY,12

e,F-DIM,12

e,F-DIM,12

e,F-DIM,12

e,F-DIM,12

e,F-DAY,12 e,F-DAY,12 e,F-DAY,12

CC

exit

exit exit

a,J4EM

a,J4EM

a,J4EM

d,J d,J d,J

d,J4EM

d,J4EMd,J

d,J4EM

c,K b,K

e,Ae,Ae,Ae,A

C C

C

3

C C

3

4

4

G-DA

Y-AR

,13

G-DA

Y-AR

,13

G-AR

,13

A,11

A,11

STORAGE492B

R2,15

R2,15

CCC,15CCC,15

CCC,15

CCC,15

CCC,15

CCC,15

CCC,15

CCC,15

CCC,15

CCC,15 CCC,15

REFER TONOTE #10

exit

TERRACE000

GENERAL LIGHTING NOTE :

Contractor shall reference the Architectural RCP drawingsfor fixture location, type, and count. Reference ElectricalLighting plans for circuiting and electrical notes.

TMGEngineeringInc.

TMG JOB NUMBER

Fax: 732-738-9672

1090 King Georges Post Rd.Suite No. 903Edison, New Jersey 08837Phone: 732-738-9670

New Jersey Certificate of AuthorizationNumber 24GA28081900

Consulting Mechanicaland Electrical Engineers

ISSUE DATE:

SHEET NUMBER:

SHEET TITLE:

Copyright (c) by Environetics, Inc. All Rights Reserved.

CHECKED BY:

DRAWN BY:

PROJECT NUMBER:

DESIGN DELIVERABLE:

REV DATE DESCRIPTION

CLIENT:

PROJECT TEAM:

SEAL

:

Structural Engineer:Environetics Design1617 JFK BLVD.,Suite 1600Philadelphia, PA 19103

Montclair, New Jersey

CLIE

NT:

Architect:Environetics Group Architects180 Sylvan Ave.Englewood Cliffs, NJ 07632

MEP Engineer:TMG Engineering Inc.1090 King Georges Post RoadSuite 903Edison, NJ 08837

Civil Engineer:Langan Engineering & Environmental Services619 River DriveCenter 1Elmwood Park, NJ 07407-1338

AV / IT / Security / Accoustical Consultant:The Sextant Group Inc.730 River AvenuePittsburgh, PASuite 600 15212

MO

NTC

LAIR

STA

TE U

NIV

ERSI

TYSC

HO

OL

OF

BUSI

NES

SM

ONT

CLAI

R, N

EW J

ERSE

Y

ADDENDUM NO. 2

06/17/13

6/14

/201

3 3:

30:5

2 PM

E-6

ELECTRICAL -FOURTH FLOORLIGHTING PLAN

Mon

tcla

ir S

t ate

Uni

vers

ity

P.B.

Ken S.

10-115

Montclair StateUniversity

10-115

FRANK S. RADOSIN N.J.P.E. 33923

1/8" = 1'-0"1 ELECTRICAL - FOURTH LEVEL - LIGHTING PLAN

M

M

M

M

M

M

M

M

M

M

M M

M

MM

M

4 5 6 9 12 15 16 18

A

B

H

K

L

M

N

O

C

17

D

11 14

G

I

197 8 12.1 14.7

E

F

J

18.9

E.1

J.9

16.110

MRO512

CHAIR530A

OFFICE532

OFFICE534

OFFICE536

OFFICE538

OFFICE540

LARGECONFERENCE

ROOM550

OFFICE554

OFFICE556

OFFICE558

OFFICE560

OFFICE562

OFFICE564

ADJUNCTHOTEL

588OFFICE

586

OFFICE584

OFFICE582

OFFICE580

LARGECONF

570

OFFICE563

OFFICE589

OFFICE587

OFFICE585

OFFICE583

OFFICE581

OFFICE553

OFFICE541

OFFICE539

OFFICE537

OFFICE535

OFFICE531

OFFICE533

SMALLCONFERENCE

510

GRADASSISTANT

508

MEN'SRESTROOM

5R02

IT5D01

ADJUNCT522

OFFICE566

OFFICE559

OFFICE561

CONFERENCE514

OFFICE557

STAIRS5S03

STAIRS6S01

CORRIDOR5C02

CORRIDOR5C01

COPY/MAIL506

MARKETING592

COPY/MAIL520

STORAGE530B

ECONOMICS& FINANCE

DEPT530

OFFICE552

CHAIR592A

CORRIDOR5C06

CCLASSROOM

511

CCLASSROOM

521

SEMINAR524

GRADASSISTANT

526

CORRIDOR5C07

WOMEN'SRESTROOM

5R01

ELEC.5E01

STORAGE508B

OFFICE555

HK5J01

NOTES :

1. EMERGENCY FIXTURES, TYPE 'J4' IN ROOMS 511, AND 521 SHALL HAVE THEIR THIRD LAMP WIRED DIRECTLY TO EMERGENCY POWER CIRCUIT 'ELP-4A-4'. THE INTENT IS FOR THESE LAMPS TO BE ENERGIZED ONLY IN THE EVENT OF THE EMERGENCY GENERATOR RUN.

2. POWER CIRCUITS FOR ALL LIGHTING, SHADES, SCREENS, ETC. INDICATED WITHIN ROOMS WITH CRESTRON PANELS SHALL BE CIRCUITED THROUGH CRESTRON PANEL.

3. ALL CORRIDOR LIGHTING SHALL BE CONTROLLED VIA LOCAL SWITCHES WITH OVERRIDE 'OFF' BY B.M.S. ALL STAIRWELL LIGHTING SHALL BE CONTROLLED BY B.M.S. SYSTEM PROVIDE LIGHTING RELAYS AND CONTACTORS AS REQUIRED.

4. ELECTRICAL ROOM AND AV/IT ROOM SHALL BE CONTROLLED BY LOCAL SWITCHES ONLY.

5. CONNECT DESIGNATED 'EM' CORRIDOR, EXITS AND ROOM LIGHTS TO EMERGENCY CIRCUIT ELP-4A-3, UNLESS OTHERWISE NOTED. ALL EMERGENCY LIGHTING SHALL REMAIN ON (UNSWITCHED) AS NIGHT LIGHTING.

6. STAIRWELL LIGHTING SHALL BE CONNECTED TO EMERGENCY CIRCUIT ELP-A-3.

7. ALL ELECTRIC PANEL LOCATIONS ARE INDICATED ON POWER DRAWINGS.

8. ALL NORMAL POWER LIGHTING CIRCUITS INDICATED ARE IN PANEL "LP-5A", UNLESS OTHERWISE NOTED. ALL NORMAL POWER LIGHTING CIRCUITS SHALL BE WIRED THROUGH FLOOR LIGHTING RELAY PANEL AND CONTROLLED VIA 'B.M.S.' SYSTEM.

9. COORDINATE ALL FIXTURE TYPES WITH ARCHITECTURAL CEILING PLANS PRIOR TO ORDERING.

10. EMERGENCY LIGHTING WITHIN THIS SPACE SHALL BE WIRED THROUGH 'CRESTRON' PANEL WITH A PHASE LOSS SENSOR TO TURN ALL EMERGENCY FIXTURES ON TO FULL BRIGHTNESS IN THE EVENT OF POWER LOSS ON THE NORMAL AND/OR EMERGENCY CIRCUIT FOR THE SPACE.

11. ALL OCCUPANCY SENSORS, WALL MOUNTED OR CEILING MOUNTED WITH OVERRIDE SWITCH SHALL BE PROGRAMMED TO BE MANUAL ON AUTO OFF. TIME DELAY FOR UNOCCUPIED SPACE SHALL BE AS DIRECTED BY THE UNIVERSITY.

12. CONTRACTOR SHALL PROVIDE AN ALTERNATE BID TO USE A SINGLE DAYLIGHT SENSOR TIED INTO ROOM 'CRESTRON' PANEL WHERE APPLICABLE IN LIEU OF DAYLIGHT HARVESTING FIXTURES.

13. ALL 'CRESTRON' PANELS INDICATEDED IN ROOMS WITHOUT CLOSETS FOR THE PANEL SHALL BE LOCATED ABOVE DROPPED CEILING.

14. ALL OCCUPANCY SENSORS WITHIN STUDY ROOMS SHALL BE CAPABLE OF INTERFACING WITH ROOMS A/V EQUIPMENT.

15. ALL LIGHTING DESIGNATED WITH DAYLIGHT HARVESTING FEATURE WITHIN ROOMS THAT ARE BEING CONTROLLED WITH 'CRESTRON' PANELS SHALL BE CONTROLLED VIA A SINGLE DAYLIGHT SENSOR WITHIN SPACE. REFER TO 'CRESTRON' DETAILS AND SPECIFICATIONS FOR MORE INFORMATION.

a,U,EMb,U

a,Ub,U

a,Ub,U

a,Ub,U

a,Ub,U

a,Ub,U

S c

MOTORIZED SHADECONTROL (TYPICAL)

S c

LP-5A10

ELP-4A5

CRESTRONPANEL

CONTROLS FLUORESCENTPORTION OF FIXTURE(TYPICAL)

CONTROLS 'MR' PORTIONOF FIXTURE - TYP.

Z,EM

Z,EM

a,Ub,U

a,U,EMb,U

S c

MOTORIZED SHADECONTROL (TYPICAL)

LP-5A9

ELP-4A5

CRESTRONPANEL

Z,EM

Z,EM

CONTROLS FLUORESCENTPORTION OF FIXTURE(TYPICAL)

CONTROLS 'MR' PORTIONOF FIXTURE - TYP.

G-DAY-AR,15

M

M

M M

G,15

G,15

F-DIM-AR,15

F-DIM-AR,15

ELP-4A4

G-DAY,15

G-DAY,15

G-DAY,15

G-DAY,15

M

M

F-DAY-AR,15 F-DAY-AR,15

F-DAY-AR,15F-DAY-AR,15

F-DIM-AR,15

F-DIM-AR,15

F-DIM-AR,15

F-DIM-AR,15

M M M M

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DIM-AR,14

F-DIM-AR,14

M M M M M

M

MM

MM

MM

MM

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

F-DAY-AR,15

MM

MM

M

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DIM-AR,14

F-DIM-AR,14

MMMMMM

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

MMMMM

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DAY-AR,14

F-DIM-AR,14

F-DIM-AR,14

M

F-DAY-AR,14F-DAY-AR,14

F-DAY-AR,14F-DAY-AR,14F-DAY,14F-DAY,14

F-DAY,14 F-DAY,14

F,14 F,14 F,14

M

M

M

F-DIM,14

F-DIM,14

F-DIM,14

F-DIM,14

G,14 G,EM

F-DAY,13 F,13 F,EM

F,EM

F,EM

F,EM F,EM

F,EM

F,EM

F,EM

F,EM

F,EMF,EMF,EM

F,EM

F,EMF-DAY,13

A,13A,13

A,13

A,13 A,13

A,EM A,13C,13

A,13

A,13

A,13 A,13 A,13

A,13

A,13

A,EM

A,EM

A,EMA,EM

A,EM

A,EMA,EM

F,13 F,13

F,13

F,13

F,13 F,13 F,13

F,13

F,13

F,13

F,13

F,13

F,13

F,13

F,13F,13F,13

F,13

F,13F,13F,13

A,13 A,13

A,13

C,13

A,13

A,13

Z,EM

Z,EM

a,A b,A

a,NNEM

b,NN b,NN b,NN b,NNEM

b,AELP-4A

5LP-5A

8

CRESTRONPANEL

S c

MOTORIZED SHADECONTROL (TYPICAL)

S c

J d

MOTORIZED SCREENCONTROL (TYPICAL)

LP-5A7

ELP-4A5

CRESTRONPANEL

a,NNEM

a,NNb,A

b,A

b,A

b,A

b,A

b,NN b,NN

b,NN

b,NN b,NN

S c

MOTORIZED SHADECONTROL (TYPICAL)

J d

MOTORIZED SCREENCONTROL (TYPICAL)

F,13L1,14 M

L1,EM

L1,EM

N,14N,14

N,14N,EM

N,14

N,14

N,14

N,14

N,14

N,14

N,14

N,EM

N,14

N,14

N,14

N,14

N,14

N,14

N,14

N,14

N,EM

N,14

N,14

N,14

a,JEM

b,J

b,JEM

a,J

b,J

a,JEM

b,J

c,AA

c,AA

c,AA

c,AA

c,F-DAY c,F-DIM

c,F-DIM

MOTORIZED SHADECONTROL (TYPICAL)

S h

c,F-DAY

S h

J f

MOTORIZED SCREENCONTROL (TYPICAL) d,K

J g

e,K

LP-4A12

CRESTRONPANEL

a,J

b,J

b,J

a,J

b,J

b,J

a,J

b,J

b,J

b,J

c,AA

c,AA

c,AA

c,AA

c,F-DAY

c,F-DAY

c,F-DIM

c,F-DIMS

h

c,F-DAY

S h

J f

d,K

J g

e,K

LP-4A11

CRESTRONPANEL

A,13A,13

exit

exitexit

exit

exit exit

exit exit

exitexit

exit

exit

exit

exit

exit

exit

exit

G,EM

G-AR

ELP-4A4

STAIR

INDICATES 'NORMAL' AND'EMERGENCY' CIRCUITFOR LIGHTING WITHINROOM. WIRE LIGHTINGTHROUGH 'CRESTRON'PANEL (TYPICAL)

INDICATES 'NORMAL' AND'EMERGENCY' CIRCUITFOR LIGHTING WITHINROOM. WIRE LIGHTINGTHROUGH 'CRESTRON'PANEL (TYPICAL)

a,NN b,NNb,NNEM b,NN b,NN

INDICATES 'NORMAL' AND'EMERGENCY' CIRCUITFOR LIGHTING WITHINROOM. WIRE LIGHTINGTHROUGH 'CRESTRON'PANEL (TYPICAL)

INDICATES 'NORMAL' AND'EMERGENCY' CIRCUITFOR LIGHTING WITHINROOM. WIRE LIGHTINGTHROUGH 'CRESTRON'PANEL (TYPICAL)

b,NNb,NNEM

b,NNEM

b,JEM

b,JEM

b,JEM

c,F-DAY c,F-DIM

A,13

A,13

A,13

N,14

N,14

N,14

MRO516

M

G-AR

FFF,13

a,Ub,U

a,Ub,U

a,Ub,U

a,Ub,U

a,Ub,U

a,U,EMb,U

CRESTRONPANEL

LP-5A15

ELP-4A5

S c S c

M

a,U,EMb,U

a,Ub,U

a,Ub,U

a,Ub,U

a,Ub,U

a,Ub,U

a,Ub,U

a,Ub,U

4

4

3

CC

CC

3

C

C

C

C

FFF,13

FFF,13

WAITINGAREA530O

A,EM

A,EM

A,EM

A,EM

GG,EM GG,EM

GG,EM GG,EM

REFER TONOTE #10

REFER TONOTE #10

REFER TONOTE #10

REFER TONOTE #10

REFER TONOTE #10

exit

exit

GENERAL LIGHTING NOTE :

Contractor shall reference the Architectural RCP drawingsfor fixture location, type, and count. Reference ElectricalLighting plans for circuiting and electrical notes.

4 5

A

B

STAIRS6S01

NOTES :

1. STAIRWELL LIGHTING SHALL BE CONNECTED TO EMERGENCY PANEL ELP-A-3.

2. COORDINATE ALL FIXTURE TYPES WITH ARCHITECTURAL CEILING PLANS PRIOR TO ORDERING.

Z,EM

Z,EM

TMGEngineeringInc.

TMG JOB NUMBER

Fax: 732-738-9672

1090 King Georges Post Rd.Suite No. 903Edison, New Jersey 08837Phone: 732-738-9670

New Jersey Certificate of AuthorizationNumber 24GA28081900

Consulting Mechanicaland Electrical Engineers

ISSUE DATE:

SHEET NUMBER:

SHEET TITLE:

Copyright (c) by Environetics, Inc. All Rights Reserved.

CHECKED BY:

DRAWN BY:

PROJECT NUMBER:

DESIGN DELIVERABLE:

REV DATE DESCRIPTION

CLIENT:

PROJECT TEAM:

SEAL

:

Structural Engineer:Environetics Design1617 JFK BLVD.,Suite 1600Philadelphia, PA 19103

Montclair, New Jersey

CLIE

NT:

Architect:Environetics Group Architects180 Sylvan Ave.Englewood Cliffs, NJ 07632

MEP Engineer:TMG Engineering Inc.1090 King Georges Post RoadSuite 903Edison, NJ 08837

Civil Engineer:Langan Engineering & Environmental Services619 River DriveCenter 1Elmwood Park, NJ 07407-1338

AV / IT / Security / Accoustical Consultant:The Sextant Group Inc.730 River AvenuePittsburgh, PASuite 600 15212

MO

NTC

LAIR

STA

TE U

NIV

ERSI

TYSC

HO

OL

OF

BUSI

NES

SM

ONT

CLAI

R, N

EW J

ERSE

Y

ADDENDUM NO. 2

06/17/13

6/14

/201

3 3:

31:0

5 PM

E-7

ELECTRICAL -FIFTH AND SIXTHFLOOR LIGHTINGPLAN

Mon

tcla

ir S

t ate

Uni

vers

ity

P.B.

Ken S.

10-115

Montclair StateUniversity

10-115

FRANK S. RADOSIN N.J.P.E. 33923

1/8" = 1'-0"1 ELECTRICAL - FIFTH LEVEL - LIGHTING PLAN