cn0162 float switch -...

3
M COM N.C. N.O. brown blue black L N M COM N.C. N.O. brown blue black L N Fig 1 Fig 4 Rated Voltage: Maximum Current: Frequency: Max. Operating Temperature: Protection Grade: AC 125V/250V 16A 50/60 Hz 50°C IP68 For water-filling operations. Connect the blue cable of the floating control to the electrical pump and the black cable to a neutral wire, as shown in Fig. 1. The brown cable should be kept insulated. For detailed installa- tion instructions, please see Fig. 2 and 3. Electrical pump begins to fill with water when the water in water tank drops to a certain level and stops working, then water rises to a certain level. USAGE INSTRUCTIONS For water-emptying operations. Connect the brown cable to the water pump and the black one to a neutral wire as shown in Fig. 4. The blue cable should be kept insulated. For detailed installation instruc- tions, please refer to Fig. 5 and 6. Fig. 5 and 6: Electrical ump stops when the water level in the water pool drops to a certain level and starts to empty water again when the water level increases. Fig 2 water tower water pool Pump Fig 3 water tower Fig 5 Fig 6 Pump CN0162 FLOAT SWITCH 48621 Warm Springs Blvd Fremont, CA 94539, USA Phone: Fax: www.temcoindustrial.com Specifications may vary and are subject to change. For certified drawings and specifications, please contact TEMCo. (510) 490-2187 (510) 490-1507 SPECIFCIATIONS

Upload: truongkhuong

Post on 25-Aug-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CN0162 FLOAT SWITCH - temcocontent.comtemcocontent.com/attachments/float_switch_temco_data_sheet.pdf · tank drops to a certain level and stops working, ... CN0162 FLOAT SWITCH Phone:

MCOM

N.C.

N.O.

brown

blue

blackLN

MCOM

N.C.

N.O.

brown

blue

blackLN

Fig 1 Fig 4

Rated Voltage:Maximum Current:Frequency:Max. Operating Temperature:Protection Grade:

AC 125V/250V16A50/60 Hz50°CIP68

For water-filling operations.

Connect the blue cable of the floating control to the electrical pump and the black cable to a neutral wire, as shown in Fig. 1. The brown cable should be kept insulated. For detailed installa-tion instructions, please see Fig. 2 and 3.

Electrical pump begins to fill with water when the water in water tank drops to a certain level and stops working, then water rises to a certain level.

USAGE INSTRUCTIONSFor water-emptying operations.

Connect the brown cable to the water pump and the black one to a neutral wire as shown in Fig. 4. The blue cable should be kept insulated. For detailed installation instruc-tions, please refer to Fig. 5 and 6.

Fig. 5 and 6: Electrical ump stops when the water level in the water pool drops to a certain level and starts to empty water again when the water level increases.

Fig 2

water tower

water pool

Pump

Fig 3

water tower

Fig 5 Fig 6

Pump

CN0162 FLOAT SWITCH

48621 Warm Springs Blvd Fremont, CA 94539, USAPhone: Fax:www.temcoindustrial.com

Specifications may vary and are subject to change. For certified drawings and specifications, please contact TEMCo.

(510) 490-2187 (510) 490-1507

SPECIFCIATIONS

Page 2: CN0162 FLOAT SWITCH - temcocontent.comtemcocontent.com/attachments/float_switch_temco_data_sheet.pdf · tank drops to a certain level and stops working, ... CN0162 FLOAT SWITCH Phone:

MCOM

N.C.

N.O.

brown

blue

black

L

NL

M

Fig 7

Fig. 7 shows the auto-switch between filling and empty-ing water, which is an extension of the two basic functions. Please refer to the two basic functions for details.

AUTO-FILLING & AUTO-EMPTYING

COUNTERWEIGHT INSTALLATION

Fig 8: Remove the plastic ring off the counterweight. Set the ring around the cable, insert the cable from the conical part into the counterweight, and fix it with moderate pressure.

1 2

Plastic ring

Fig 8

CN0162 FLOAT SWITCH

48621 Warm Springs Blvd Fremont, CA 94539, USAPhone: Fax:www.temcoindustrial.com

Specifications may vary and are subject to change. For certified drawings and specifications, please contact TEMCo.

(510) 490-2187 (510) 490-1507

Page 3: CN0162 FLOAT SWITCH - temcocontent.comtemcocontent.com/attachments/float_switch_temco_data_sheet.pdf · tank drops to a certain level and stops working, ... CN0162 FLOAT SWITCH Phone:

5) When the liquid level drops to the point at which the float passes 45° hanging, the internal switch will actuate, closing the normally open contact (NO) and opening the normally closed contact (NC).

6) When the liquid level rises to the point at which the float passes 45° upward, the internal switch will actuate, re-opening the normally open contact (NO) and re-closing the normally closed contact (NC).

INSTALLATION

4) Locate the counterweight according to your desired float pivot point. The length of the cord between the counter-weight and the float determine the liquid level cycle range.

3) Insert the cord in the conical part of the counterweight and over the lock ring.

2) Clip plastic lock ring to the cord where you would like the counterweight positioned.

1) Remove the attached plastic lock ring from the counter-weight.

CN0162 FLOAT SWITCH

48621 Warm Springs Blvd Fremont, CA 94539, USAPhone: Fax:www.temcoindustrial.com

Specifications may vary and are subject to change. For certified drawings and specifications, please contact TEMCo.