coaxial cable, pvc/pe - power & tel info/voice-video... · coaxial cable, pvc/pe part no....

24
1 CCTV and Camera Cable Security and Alarm Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1 RG-62 IBM 22 Solid CCS 95% BC Braid 93 PVC .242 38 1C22W162AU2 RG-62 Outdoor 22 Solid CCS 95% BC Braid 93 PVC .260 40 1C22W159U RG-59 22 Solid CCS 70% BC Braid 73 PVC .242 36 1C22W159U1 RG-59 22 Solid CCS 95% BC Braid 75 PVC .242 40 1C20W159U1 RG-59 Outdoor, Sunlight Resistant 20 Solid CCS 95% BC Braid 75 PVC .242 40 1C20W159U3 RG-59 20 Solid CCS 80% BC Braid 75 PVC .242 30 1C20B159U1 RG-59 20 Solid BC 95% BC Braid 75 PVC .242 34 120W159U1DB RG-59 Outdoor Direct Burial 20 Solid CCS 95% BC Braid 75 PE .239 35 120B159U1DB RG-59 Outdoor Direct Burial 20 Solid BC 95% BC Braid 75 PE .242 36 2C22W159U RG-59 Dual Wang 22 Solid CCS 95% BC Braid 75 PVC .238 x .478 84 1C20B158U RG-58 20 Solid BC 95% TC Braid 51.5 PVC .195 30 1C20T1958AU RG-58 20 Stranded TC 95% TC Braid 50 PVC .193 30 1C20T19NET RG-58 Thin Net 20 Stranded TC Foil + 93% TC Braid 50 PVC .185 26 1C20B158U2 RG-58 Outdoor 20 Solid BC 95% TC Braid 55 PE .195 34 1C11B78U1 RG-8 11 Stranded BC 97% BC Braid 50 PVC .403 112 1C18B1NET RG-6 18 Solid BC Foil + 60% TC Braid 75 PVC .275 40 1P20X7TWAXS Twinax 20 Stranded 1-TC, 1-BC Foil + 90% TC Braid 100 PVC .330 70 1P20X7TWAX1 Twinax Outdoor 20 Stranded 1-TC, 1-BC 85% TC Braid 100 PE .330 72 2C20T7TWAX1 Blue Hose 20 Stranded TC Foil + 57% TC Braid 78 PVC .243 39 Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22B759U RG-59 - CCTV 22 Stranded BC 95% BC Braid 76 PVC .242 45 1C14B111U RG-11 - CCTV 14 Solid BC 95% BC Braid 75 PVC .405 90 1C18B16U4 RG-6 - CCTV 18 Solid BC 95% BC Braid 75 PVC .270 36 3C22X759U Siamese RG-59 Control Pair 22 AWG 22 Stranded BC with 1 pr. 22 Shielded Foil on Pair 95% BC Braid 76 PVC .242 x .445 75 Coaxial Cable www.ptsupply.com [email protected] 800-238-7514

Upload: others

Post on 27-Apr-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

1

CCTV and Camera Cable Security and Alarm

Coaxial Cable, PVC/PE

Part No. Description AWG Conductor Shield Ohms JacketNominal O.D. (in)

Weight (lbs/M-ft)

1C22W162AU1 RG-62 IBM 22 Solid CCS 95% BC Braid 93 PVC .242 38

1C22W162AU2 RG-62 Outdoor 22 Solid CCS 95% BC Braid 93 PVC .260 40

1C22W159U RG-59 22 Solid CCS 70% BC Braid 73 PVC .242 36

1C22W159U1 RG-59 22 Solid CCS 95% BC Braid 75 PVC .242 40

1C20W159U1 RG-59 Outdoor, Sunlight Resistant

20 Solid CCS 95% BC Braid 75 PVC .242 40

1C20W159U3 RG-59 20 Solid CCS 80% BC Braid 75 PVC .242 30

1C20B159U1 RG-59 20 Solid BC 95% BC Braid 75 PVC .242 34

120W159U1DBRG-59 Outdoor Direct Burial

20 Solid CCS 95% BC Braid 75 PE .239 35

120B159U1DBRG-59 Outdoor Direct Burial

20 Solid BC 95% BC Braid 75 PE .242 36

2C22W159U RG-59 Dual Wang 22 Solid CCS 95% BC Braid 75 PVC .238 x .478 84

1C20B158U RG-58 20 Solid BC 95% TC Braid 51.5 PVC .195 30

1C20T1958AU RG-58 20 Stranded TC 95% TC Braid 50 PVC .193 30

1C20T19NET RG-58 Thin Net 20 Stranded TC Foil + 93% TC Braid 50 PVC .185 26

1C20B158U2 RG-58 Outdoor 20 Solid BC 95% TC Braid 55 PE .195 34

1C11B78U1 RG-8 11 Stranded BC 97% BC Braid 50 PVC .403 112

1C18B1NET RG-6 18 Solid BC Foil + 60% TC Braid 75 PVC .275 40

1P20X7TWAXS Twinax 20 Stranded 1-TC, 1-BC Foil + 90% TC Braid 100 PVC .33070

1P20X7TWAX1 Twinax Outdoor 20 Stranded 1-TC, 1-BC 85% TC Braid 100 PE .330 72

2C20T7TWAX1 Blue Hose 20 Stranded TC Foil + 57% TC Braid 78 PVC .243 39

Part No. Description AWG Conductor Shield Ohms JacketNominal O.D. (in)

Weight (lbs/M-ft)

1C22B759U RG-59 - CCTV 22 Stranded BC 95% BC Braid 76 PVC .242 45

1C14B111U RG-11 - CCTV 14 Solid BC 95% BC Braid 75 PVC .405 90

1C18B16U4 RG-6 - CCTV 18 Solid BC 95% BC Braid 75 PVC .270 36

3C22X759U Siamese

RG-59 Control Pair 22 AWG

22Stranded BC with 1 pr. 22 Shielded

Foil on Pair 95% BC Braid

76 PVC .242 x .445 75

Coaxial Cable

[email protected] 800-238-7514

Page 2: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

2

Coaxial Cable, Plenum

Coaxial Cable, ArmoredArmored coaxial cable features PVC inner and outer jackets with corrugated aluminum armor between.

Part No. Description AWG Conductor Shield OhmsNom. O.D.

(in)Weight

(lbs/M-ft)

1C22W162AUP RG-62 22 Solid CCS 96% BC Braid 93 .200 40

1C22W1IBMP RG-62 IBM 22 Solid CCS 96% BC Braid 93 .200 42

1C20W159UP RG-59 20 Solid CCS 95% BC Braid 75 .196 36

2C22W159USP RG-59 Dual Wang 22 Solid CCS 97% BC Braid 75 .212 x .424 98

1C20B158UP RG-58 20 Solid BC 95% TC Braid 53.5 .161 35

1C14B111UP RG-11 14 Solid BC Foil + 95% TC Braid 75 .352 115

1C18B16UP1 RG-6 18 Solid BC Foil + 95% TC Braid 75 .240 44

1C18B16UP RG-6 18 Solid BC 95% BC Braid 75 .228 43

1C20B159UP RG-59 20 Solid BC 95% BC Braid 75 .193 31

1C12B1NETP Ethernet 12 Solid BC Foil + 90% TC Braid 50 .247148

1C20T19NETP Thin Net 20 Stranded TC Foil + 93% TC Braid 50 .165 30

1P20X7TWAXP Twinax 20 Stranded 1-TC, 1-BC Foil + 85% TC Braid 100 .26745

3C22X759UP Siamese 221 pr. 22 AWG Stranded TC, Stranded BC

Pair Shielded 95% TC Braid

75 .210 x .359 45

Part No. Description AWG Conductor Shield Ohms JacketNom. O.D.

(in)Weight

(lbs/M-ft)

2C20T7TWAXA Blue Hose 20 Stranded TC Foil + 55% TC Braid 78 PVC .563 122

Coaxial Cable

[email protected] 800-238-7514

Page 3: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

3

Broadband Coaxial CATV

Recommendations

11/u for distances over 175'

6/u for distances to 175'

59/u minimum capacity requirements

•••

See referenced pages in the Hardware & Supplies section:

Installation HardwareAcme 37AC Staple Gun - I-3

Suggested Prep ToolUniversal Drop Trimmer - I-9

Table courtesy of Belden.

Note: Attenuation numbers are valid at 68°F (20°C)

Series 11Series 6Series 59Freq. (MHz)

Nom Atten. dB/100'

Max. Atten. dB/100'

Nom Atten. dB/100'

Max. Atten. dB/100'

Nom Atten. dB/100'

Max. Atten. dB/100'

Attenuation Values for Broadband Cables

5 0.55 0.58 0.42 0.45 0.26 0.29

55 1.83 1.95 1.42 1.53 0.89 0.97

211 3.61 3.82 2.79 3.02 1.74 1.92

216 3.66 3.87 2.83 3.06 1.76 1.95

240 3.86 4.09 2.99 3.23 1.86 2.06

270 4.10 4.35 3.17 3.44 1.98 2.19

300 4.33 4.58 3.35 3.64 2.09 2.32

325 4.51 4.78 3.49 3.79 2.18 2.42

350 4.69 4.96 3.63 3.93 2.28 2.51

375 4.85 5.14 3.76 4.08 2.36 2.61

400 5.02 5.31 3.89 4.21 2.44 2.70

450 5.33 5.64 4.13 4.47 2.60 2.86

500 5.62 5.95 4.36 4.72 2.74 3.03

550 5.90 6.25 4.57 4.95 2.88 3.18

600 6.17 6.54 4.78 5.18 3.02 3.33

650 6.45 6.83 4.97 5.41 3.14 3.47

700 6.73 7.13 5.17 5.63 3.27 3.61

750 6.97 7.39 5.35 5.83 3.39 3.74

800 7.20 7.64 5.54 6.03 3.51 3.87

862 7.48 7.94 5.75 6.27 3.64 4.02

870 7.52 7.98 5.78 6.30 3.66 4.04

900 7.66 8.12 5.89 6.41 3.73 4.11

950 7.87 8.35 6.05 6.60 3.84 4.23

1000 8.09 8.58 6.22 6.78 3.94 4.35

Part No. Description AWG Conductor Shield Jacket Nom. O.D. (in) Weight (lbs/M-ft)

CATV Drop - 75 Ohm, for interior horizontal, lashed outdoor aerial drop and conduit installation

1C20W15967 RG-59 20 Solid CCS Foil + 67% Alum. Braid PVC .240 28

1C18W1660 RG-6 18 Solid CCS Foil + 60% Alum. Braid PVC .272 33

1C18W1QUAD6 RG-6 Quad Shield 18 Solid CCSFoil + 60% Alum. Braid Tape + 42% Alum. Braid

PVC .300 38

1C14W11160 RG-11 14 Solid CCS Foil + 60% Alum. Braid PVC .395 65

1C14W1QD11 RG-11 Quad Shield 14 Solid CCSFoil + 60% Alum. Braid Tape + 40% Alum. Braid

PVC .405 77

CATV Drop Flooded - 75 Ohm, for underground installation

1C20W159F57 RG-59 20 Solid CCS Foil + 67% Alum. Braid PE .240 24

1C18W16F60 RG-6 18 Solid CCS Foil + 60% Alum. Braid PE .272 33

1C18W1Q6F RG-6 Quad Shield 18 Solid CCSFoil + 60% Alum. Braid Tape + 40% Alum. Braid

PE .272 45

1C14W111F60 RG-11 14 Solid CCS Foil + 60% Alum. Braid PE .395 60

1C14W1Q11F RG-11 Quad Shield 14 Solid CCSFoil + 60% Alum. Braid Tape + 40% Alum. Braid

PE .395 58

CATV Self-Supporting Figure-8 - 75 Ohm

1C20W159M67RG-59 .051" messenger

20 Solid CCS Foil + 67% Alum. Braid PVC .240 45

1C18W16M60RG-6 .051" messenger

18 Solid CCS Foil + 60% Alum. Braid PVC .272 48

1C14W111M60RG-11 .072" messenger

14 Solid CCS Foil + 60% Alum. Braid PVC .395 99

Coaxial Cable

[email protected] 800-238-7514

Page 4: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

4

Siamese Coaxial CableAvailable with either dual coaxial cables or coaxial cable with a twisted

pair and also in a plenum-rated design for installation in a drop ceiling or a raised floor.

These cables are easier to install than standard coaxial cables and are ideal for dual Direct Broadcast System (DBS) applications where one dish is used to serve two receivers. They also are critical for satellite hookup where a powered-pair cable is desired. Other applications for these coaxial cables include sound and security surveillance cameras where the coaxial cable transmits the audio/video signal and the twisted pair is used to control the pan and tilt function of the closed-circuit television (CCTV) camera.

In today’s uncertain world, security installations are occurring at a double-digit growth rate. Security cameras are being installed in virtually every office, school and government facility, on highways and in traffic control centers as well as in most industrial, commercial and manufactur-ing facilities.

See referenced pages in the Hardware & Supplies section:

Installation HardwareCollapsible Cable Caddy - I-3

Suggested Prep ToolsDrop Cable Slitter DCS - H-7Coaxial Cable Cutter - I-5Universal Drop Trimmer - I-9

•••

Part No. Description AWG Conductor Shield Ohms Jacket

Nom. O.D. (in)

Weight (lbs/M-ft)

2C18WI6DUAL RG-6 - CATV 18 Solid CCS Foil + 60% Alum. Braid 75 PVC .270 x .595 60

3C18B1RG6U RG-6 - CATV 18 Solid BCFoil + 95% TC Pair 18 Stranded Unshielded

75 PVC .270 x .493 78

2C20W159US RG-59 - Dual CATV 20 Solid CCS Foil + 67% Alum. Braid 75 PVC .242 x .498 60

3C22X759U RG-59 - CATV 22 Stranded BC 95% BC with Foil on 76 PVC .242 x .445 75

3C20X159U1 RG-59 - CATV 20 Solid BC 95% BC 75 PVC .238 x .440 75

3C20B059UP RG-59 - CMP 20 Solid BC 95% BC 75 Plenum .200 x .383 53

Coaxial Cable

[email protected] 800-238-7514

Page 5: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

5

By installing a single composite cable throughout the Intelligent Home, Residential cable means that every room is already wired for:

Analog or digital cable and satellite television

Cable modem service

Multiple telephone lines

High-speed Internet access

Video monitors and security systems

Lighting and energy management systems

Networked audio from stereos and home theater systems

Home office systems

Shared access to home entertainment components such as DVDs, VCRs and CD players

Networked computer peripherals such as printers and scanners, with high-speed Ethernet capabilities

•••••••••

Multimedia Cable Delivers the Future Multimedia products include broadband coaxial cables and data cables – and, in some configurations, fiber optic cables – IN A SINGLE JACKET. They allow you to install plug-and-play points throughout the home for TV, multimedia, data and telephone communications.

VERIFIED

Green, Flame-retardant, PVC, .625" Part No. 20C0X07878A

Same as above, plus:One 2-fiber LANLite® Distribution Cable

Gigabit ethernet-grade fiber 62.5/125/900 Micron tight buffered fiber

Other constructions available, call for more information.

Green, Flame-retardant, PVC, .6" Part No. 18C0X07876A

Two Series 6 coaxial cables Duobond Plus Series 6 (solid copper conductor) Duobond Plus (Bonded Tri-shield) + 80% Braid, swept to 2.25 GHz Two Cat 5E 4 pair bonded UTP cables UTP verified (UL) to Category 5E 24 AWG solid bare copper, polyolefin insulation

See referenced pages in the Hardware & Supplies section:

Suggested Prep ToolsMK01A Multi-wire Stripper/Cutter - I-11SDT 596-250 Single Drop Trimmer - I-9 For the RG-6 series cables. A CAT tool (Compression Assembly Tool) or Hex Crimp Tool is needed for installing the RG-6 cable. This tool is dependent on the style of connector being used on the cable. It will be either a Hex Crimp- or Compression-style connector 103-S Fiber Optic Stripper - I-10 For the 62.5/125/900 Micron tight buffered fiber.

Data Communications

[email protected] 800-238-7514

Page 6: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

6

Multimedia Banana Peel® Cable Cable solutions from Belden for home automation, networking, security and entertainment systems.

The overall jacket has been eliminated to make Banana Peel® cables easy to identify, easy to pull and easy to terminate.

VERIFIED

Benefits

Patent-pending design affixes the individual cables to a center spline, eliminating the need for an overall jacket

Cables have a smaller O.D. than traditional composite cables, improv-ing the cable's overall bend radius for faster, easier installation

Individual data, coax and fiber cable components are all instantly identifiable and ready for termination - just peel the individual cables off the center spline

Verified Category 5E Performance

Available in two configurations:

2 x 2 (two data cables, two coaxes)

2 x 2 x 2 (two data cables, two coaxes and two fibers)

All are rated CMR/C (UL) CMG FT4, and all come standard on 500' and 1,000' reels.

Banana Peel® cables include:

Belden 7876S — Two Cat 5E 4-pair bonded UTP data cables, plus two Series 6 Duobond Plus® coaxial cables

Belden 7878S — Two Cat 5E 4-pair bonded UTP data cables, plus two Series 6 Duobond Plus® coaxes and one 2-fiber LANLite® distribution cable

Belden 7913S — Two Cat 5E 4-pair UTP data cables, plus two Series 6 Duobond IV Quad Shield® coaxes

Belden 7914S — Two Cat 5E 4-pair UTP cables, plus two Series 6 Duobond IV Quad Shield® coaxes and one 2-fiber LANLite® distribu-tion cable.

••

Data Communications

Data Communications

[email protected] 800-238-7514

Page 7: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

7

Category 6E Twisted Pair Data Cables CMR/CMPStandard Compliances

ANSI/TIA/EIA-568-B.2-1 (Category 6)ANSI/TIA/EIA-862 (Building Automation)ISO/IEC 11801 Ed. 2.0 (Class E)ICEA S-102-700 (Category 6)UL and c(UL) Type CMR (UL 1666) for Non-PlenumUL and c(UL) Type CMP (NFPA 262) for PlenumUL 444

Applications

IEEE 802.3: 1000BASE-T (Gigabit Ethernet), 100BASE-TX, 10BASE-TANSI/TIA/EIA-854: 1000BASE-TX155 Mp/s, 1.2 Gb/s ATMANSI X3.263: 100Mb/sIEEE 802.3af DTE Power (POE)4/16 Mb/s Token RingDigital VideoBroadband and Baseband analog video

•••••••

•••••••

Part No. 4P23B1CMR6E – Non-PlenumPart No. 4P23B1CMP6E – Plenum

Note: Values are expressed in dB per 100m (328 ft) length.

See referenced pages in the Hardware & Supplies section:

Installation HardwareAcme 25AC Staple Gun - I-3

Suggested Prep ToolsSMART-STRIP Stripper - I-11Universal Drop Trimmer - I-9

••

Frequency MHz

PSACR min.

ACR min.

Attenuation max.

PSNEXT min.

NEXT min.

PSELFEXT min.

ELFEXT min.

Return Loss min.

LCL min. ELTCTL

1 74.3 76.3 2 76.3 78.3 71.8 74.8 20 50 35

4 63.6 65.6 3.7 67.3 69.3 59.7 62.7 23 44 23

10 55.5 57.5 5.8 61.3 63.3 51.8 54.8 25 40 15

16 50.8 52.8 7.4 58.2 60.2 47.7 50.7 25 38 10.9

20 48.5 50.5 8.3 56.8 58.8 45.7 48.7 25 37 9

31.25 43.4 45.4 10.5 53.9 55.9 41.9 44.9 23.6 35.1 5.1

62.5 34.3 36.3 15.1 49.4 51.4 35.8 38.8 21.5 32 -

100 26.9 28.9 19.4 46.3 48.3 31.8 34.8 20.1 30 -

200 13.4 15.4 28.4 41.8 43.8 25.7 28.7 18 27 -

250 8.1 10.1 32.2 40.3 42.3 23.8 26.8 17.3 26 -

300 3.4 5.4 35.7 39.1 41.1 22.2 25.2 16.8 25.2 -

350 - 1.1 39 38.1 40.1 20.9 23.9 16.3 24.6 -

400 - - 42.1 37.3 39.3 19.7 22.7 15.9 24 -

500 - - 48 35.8 37.8 17.8 20.8 15.2 23 -

Electrical Performance (typical)

Data Communications

[email protected] 800-238-7514

Page 8: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

8

Category 6 Twisted Pair Data Cables Unshielded Twisted Pair (UTP) CMR/CMPStandard Compliances

ANSI/TIA/EIA-568-B.2-1 (Category 6)

ANSI/TIA/EIA-862 (Building Automation)

ISO/IEC 11801 Ed. 2.0 (Class E)

ICEA S-102-700 (Category 6)

UL and c(UL) Type CMR (UL 1666) for Non-Plenum

UL and c(UL) Type CMP (NFPA 262) for Plenum

UL 444

Applications

IEEE 802.3: 1000BASE-T (Gigabit Ethernet), 100BASE-TX, 10BASE-T

ANSI/TIA/EIA-854: 1000BASE-TX

155 Mp/s, 1.2 Gb/s ATM

ANSI X3.263: 100Mb/s

IEEE 802.3af DTE Power (POE)

4/16 Mb/s Token Ring

Digital Video

Broadband and Baseband analog video

Part No. 4P23B1CMR6 – Non-PlenumPart No. 4P23B1CMP6 – Plenum

•••••••

•••••••

Note: Values are expressed in dB per 100m (328 ft) length.

See referenced pages in the Hardware & Supplies section:

Installation HardwareAcme 25AC Staple Gun - I-3

Suggested Prep ToolsSMART-STRIP Stripper - I-11Universal Drop Trimmer - I-9

••

Frequency MHz

PSACR min.

ACR min.

Attenuation max.

PSNEXT min.

NEXT min.

PSELFEXT min.

ELFEXT min.

Return Loss min.

LCL min. ELTCTL

1 71.3 73.3 2.0 73.3 75.3 65.8 68.8 20.0 50.0 35.0

4 60.5 62.5 3.8 64.3 66.3 53.8 56.8 23.0 44.0 23.0

10 52.4 54.4 5.9 58.3 60.3 45.8 48.8 25.0 40.0 15.0

16 47.7 49.7 7.5 55.3 57.3 41.7 44.7 25.0 38.0 10.9

20 45.4 47.4 8.4 53.8 55.8 39.8 42.8 25.0 37.0 9.0

31.25 40.3 42.3 10.6 50.9 52.9 37.8 38.9 23.6 35.1 5.1

62.5 31.1 33.1 15.3 46.4 48.4 29.9 32.9 21.5 32.0 -

100 23.6 25.6 19.7 43.3 45.3 25.8 28.8 20.1 30.0 -

200 9.9 11.9 28.8 38.8 40.8 19.8 22.8 18.0 27.0 -

250 4.6 6.6 32.7 37.3 39.3 17.8 20.8 17.3 26.0 -

350 - 2.0 39.6 35.2 37.2 - - - 24.6 -

400 - - 42.7 34.3 36.3 - - - 24.0 -

500 - - 48.7 32.8 34.8 - - - 23.0 -

Electrical Performance (typical)

Data Communications

[email protected] 800-238-7514

Page 9: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

9

Standard Compliances

ANSI/TIA/EIA-568-B.2 (Category 5E)

ANSI/TIA/EIA-862 (Building Automation)

ISO/IEC 11801 Ed. 2.0 (Class D)

ICEA S-90-661 (Category 5E)

UL and c(UL) Type CMR (UL 1666) for Non-Plenum

UL and c(UL) Type CMP (NFPA 262) for Plenum

UL 444

Applications

IEEE 802.3: 1000BASE-T (Gigabit Ethernet)

100BASE-TX, 10BASE-T

155 Mp/s, 622 Mp/s ATM

ANSI X3.263: 100Mb/s

4/16 Mb/s Token Ring

Broadband and Baseband analog video

Part No. 4P24B1CT5EE – Non-PlenumPart No. 4P24B1C5EEP – Plenum

•••••••

••••••

Category 5E Enhanced Twisted Pair Data Cables Unshielded Twisted Pair (UTP) CMR/CMP

Note: Values are expressed in dB per 100m (328 ft) length.

See referenced pages in the Hardware & Supplies section:

Installation HardwareAcme 25AC Staple Gun - I-3

Suggested Prep ToolsSMART-STRIP Stripper - I-11Universal Drop Trimmer - I-9

••

Frequency MHz

PSACR min.

ACR min.

Attenuation max.

PSNEXT min.

NEXT min.

PSELFEXT min.

ELFEXT min.

Return Loss min.

1 68.1 70.1 1.9 68.3 70.3 62.0 65.0 20.0

4 57.1 59.1 3.9 59.3 61.3 50.0 53.0 23.0

10 48.9 50.9 6.1 53.3 55.3 42.0 45.0 25.0

16 44.1 46.1 7.8 50.3 52.3 37.9 40.9 25.0

20 41.7 43.7 8.8 48.8 50.8 36.0 39.0 25.0

31.25 36.4 38.4 11.2 45.9 47.9 32.1 35.1 23.6

62.5 26.9 28.9 16.2 41.4 43.4 26.1 29.1 21.5

100 19.0 21.0 21.0 38.3 40.3 22.0 25.0 20.1

155 10.3 12.3 26.8 35.5 37.5 18.2 21.2 18.8

200 4.5 6.5 31.0 33.8 35.8 16.0 19.0 18.0

250 - 0.8 35.3 32.3 34.3 14.0 17.0 17.3

300 - - 39.2 31.2 33.2 12.5 15.5 16.8

350 - - 43.0 30.2 32.2 11.1 14.1 16.3

Electrical Performance (typical)

Data Communications

[email protected] 800-238-7514

Page 10: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

10

Category 5E Twisted Pair Data Cables Unshielded Twisted Pair (UTP) CMR/CMP, 100 MbpsStandard Compliances

ANSI/TIA/EIA-568-B.2 (Category 5E)

ANSI/TIA/EIA-862 (Building Automation)

ISO/IEC 11801 Ed. 2.0 (Class D)

ICEA S-90-661 (Category 5E)

UL and c(UL) Type CMR (UL 1666) for Non-Plenum

UL and c(UL) Type CMP (NFPA 262) for Plenum

UL 444

Applications

IEEE 802.3: 1000BASE-T (Gigabit Ethernet); 100BASE-TX, 10BASE-T

52/155 Mp/s ATM

ANSI X3.263: 100Mb/s

4/16 Mb/s Token Ring

Part No. 4P24B1CT5E1 White – Non-Plenum Part No. 4P24B1CT5E4 Blue – Non-Plenum*

Part No. 4P24B1CMS5E – Shielded

Part No. 25P24B1CAT5E – Non-PlenumPart No. 25P24B1CMP5E – Plenum

*Other colors available upon request.

•••••••

••••

Note: Values are expressed in dB per 100m (328 ft) length.

See referenced pages in the Hardware & Supplies section:

Installation HardwareAcme 25AC Staple Gun - I-3

Suggested Prep ToolsSMART-STRIP Stripper - I-11Universal Drop Trimmer - I-9

••

Frequency MHz

PSACR min.

ACR min.

Attenuation max.

PSNEXT min.

NEXT min.

PSELFEXT min.

ELFEXT min.

Return Loss min.

1 60.3 63.3 2.0 62.3 65.3 60.8 63.8 20.0

4 49.2 52.2 4.1 53.3 56.3 48.7 51.7 23.0

10 40.8 43.8 6.5 47.3 50.3 40.8 43.8 25.0

16 36.0 39.0 8.2 44.2 47.2 36.7 39.7 25.0

20 33.5 36.5 9.3 42.8 45.8 34.7 37.7 25.0

25 30.9 33.9 10.4 41.3 44.3 32.8 35.8 24.3

31.25 28.2 31.2 11.7 39.9 42.9 30.9 33.9 23.6

62.5 18.4 21.4 17.0 35.4 38.4 24.8 27.8 21.5

100 10.3 13.3 22.0 32.3 35.3 20.8 23.8 20.1

155 1.4 4.4 28.1 29.4 32.4 16.9 19.9 -

200 - - 32.4 27.8 30.8 14.7 17.7 -

250 - - 36.9 26.3 29.3 12.8 15.8 -

Electrical Performance (typical)

Data Communications

[email protected] 800-238-7514

Page 11: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

11

Cat 5 & 5E Direct Burial Cables Non-Gopher and Gopher Resistant

Applications Provides extension of the LAN beyond the premises; various constructions meet many environmental needs.

4 or 16 Mbps Token ring (IEEE 802.5)

100 Mbps (ANSI X 3T9.5 TPDDI)

155 Mbps ATM systems designed for Cat 5

Meets Category 5 Transmission requirements of TIA/EIA 568A for horizontal cable

10 Mbps Ethernet (IEEE 802.3)

••••

Category 3 Twisted Pair Data Cables

Application Low-speed data, premises phone wiring.

Suitable for IEEE 802.3, 10 BASE T, 10 Mbps

Suitable for IEEE 802.5 16 Mbps Token Ring in limited applications

Meets TIA/EIA 568 Category 3 and NEMA Standard Requirements

••

*Shield types: A = Aluminum TapeG = Copper-clad Armor for rodent resistance

See referenced page in the Hardware & Supplies section:

Suggested Prep ToolsSMART-STRIP Stripper - I-11•

See referenced page in the Hardware & Supplies section:

Suggested Prep ToolsSMART-STRIP Stripper - I-11•

Conductors 24 AWG

Insulation PE

Configuration Twisted Pairs

Jacket Black PE; water and UV resistant

Specifi cations

Part No. Pairs O.D. (in)Weight

(lbs/M-ft)

4P24B1C5E0 Unshielded

4 .31 52

4P24B1CT5EA* 4 .31 52

4P24B1CT5EG* 4 .33 68

25P24B1CM5A* 25 .63 250

25P24B1CM5G* 25 .67 285

Conductors 24 AWG solid bare copper

Insulation PE or FEP

Configuration Twisted pairs, unshielded

Jacket PVC or Plenum

Specifi cations

Part No. Pairs Jacket O.D. (in)Weight

(lbs/M-ft)

2P24B1CMR3 2 PVC .130 12

2P24B1CMP3 2 Plenum .130 12

3P24B1CMR3 3 PVC .140 16

3P24B1CMP3 3 Plenum .140 14

4P24B1CMR3 4 PVC .152 20

4P24B1CMP3 4 Plenum .160 18

6P24B1CMR3 6 PVC .185 28

6P24B1CMP3 6 Plenum .185 26

12P24B1CMR3 12 PVC .240 50

12P24B1CMP3 12 Plenum .245 52

25P24B1CMR3 25 PVC .345 115

25P24B1CMP3 25 Plenum .330 106

32P24B1CMR3 32 PVC .360 150

50P24B1CMR3 50 PVC .450 190

50P24B1CMP3 50 Plenum .460 240

100P24B1CMR3 100 PVC .650 450

100P24B1CMP3 100 Plenum .640 460

200P24B1CMR3 200 PVC 1.02 724

200P24B1CMP3 200 Plenum 1.10 728

4P24B1CT5EG

Data Communications

[email protected] 800-238-7514

Page 12: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

12

Twisted Pair Plenum Each Pair Individually Shielded NEC® 725 Type CMP

See referenced pages in the Hardware & Supplies section:

Installation HardwareAcme 25AC Staple Gun - I-3

Suggested Prep Tool721 Multi-Wire Stripper/Cutter - I-9

Applications Special audio, communications and instrumentation uses requiring shielded groups to isolate circuits.

Conductors Stranded, tinned copper

Insulation Low smoke-producing, low flame-spread compounds with cross-reference

Shield Mylar/aluminum foil tape shields on each pair with common 24 AWG stranded tinned copper drain wire

Configuration Twisted pairs, color-coded

Jacket Low smoke-producing, low flame-spread approved compounds

Specifi cations

Part No. No. PairNominal O.D. (in)

Weight (lbs/M-ft) Color Code

2P22T7EPSP 2 .174 33Pair 1: Red/Black Pair 2: Black/White

3P22T7EPSP 3 .241 52Pair 1: Red/Black Pair 2: Black/White Pair 3: Black/Green

6P22T7EPSP 6 .346 90

Pair 1: Red/Black Pair 2: Black/White Pair 3: Black/Green Pair 4: Black/Blue Pair 5: Black/Yellow Pair 6: Black/Brown

Data Communications

[email protected] 800-238-7514

Page 13: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

13

Applications Public address systems, intercom systems, interconnecting cables, remote control circuits, low-voltage relay controls where RF shielding is not required.

Straight Conductor Unshielded NEC® Type CM

See referenced pages in the Hardware & Supplies section:

Installation HardwareAcme 25AC Staple Gun - I-3

Suggested Prep Tools100 Adjustable Wire Stripper/Cutter - I-9721 Multi-Wire Stripper/Cutter - I-9

Some air plenum designs also available.

Part No.No. of Cond. AWG

Cond. Stranding

Nom. Insulation

Thickness (in)Nom. Jacket

Thickness (in)Nominal O.D. (in)

2C22T7NS 2 22 7/30 .010 .030 .165

3C22T7NS 3 22 7/30 .010 .030 .170

4C22T7NS 4 22 7/30 .010 .030 .180

5C22T7NS 5 22 7/30 .010 .030 .195

6C22T7NS 6 22 7/30 .010 .030 .210

7C22T7NS 7 22 7/30 .010 .030 .210

8C22T7NS 8 22 7/30 .010 .030 .230

9C22T7NS 9 22 7/30 .010 .030 .245

10C22T7NS 10 22 7/30 .010 .030 .265

12C22T7NS 12 22 7/30 .010 .030 .270

15C22T7NS 15 22 7/30 .010 .030 .290

18C22T7NS 18 22 7/30 .010 .030 .315

20C22T7NS 20 22 7/30 .010 .030 .330

25C22T7NS 25 22 7/30 .010 .030 .365

30C22T7NS 30 22 7/30 .010 .030 .400

40C22T7NS 40 22 7/30 .010 .040 .450

50C22T7NS 50 22 7/30 .010 .040 .500

2C20T10NS 2 20 10/30 .015 .030 .200

3C20T10NS 3 20 10/30 .015 .030 .210

4C20T10NS 4 20 10/30 .015 .030 .230

5C20T10NS 5 20 10/30 .015 .030 .256

7C20T10NS 7 20 10/30 .015 .030 .270

9C20T10NS 9 20 10/30 .015 .030 .320

12C20T10NS 12 20 10/30 .015 .035 .350

15C20T10NS 15 20 10/30 .015 .040 .405

2C18T16NS 2 18 16/30 .018 .030 .230

3C18T16NS 3 18 16/30 .018 .030 .245

4C18T16NS 4 18 16/30 .018 .030 .265

5C18T16NS 5 18 16/30 .018 .037 .300

7C18T16NS 7 18 16/30 .018 .037 .324

9C18T16NS 9 18 16/30 .018 .037 .379

12C18T16NS 12 18 16/30 .018 .040 .430

15C18T16NS 15 18 16/30 .018 .045 .485

19C18T16NS 19 18 16/30 .018 .045 .510

25C18T16NS 25 18 16/30 .018 .060 .625

2C16T26NS 2 16 19/29 .020 .030 .265

3C16T26NS 3 16 19/29 .020 .030 .280

4C16T19NS 4 16 19/29 .030 .045 .375

2C14T19NS 2 14 19/27 .030 .030 .335

2C12T19NS 2 12 65/30 .030 .030 .375

Conductors Stranded, tinned copper

Insulation PVC

Shield None

Jacket Gray PVC

Specifi cations

Audio & Communications

[email protected] 800-238-7514

Page 14: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

14

Straight Conductor Shielded NEC® Type CL2 or CM

See referenced pages in the Hardware & Supplies section:

Installation HardwareAcme 25A or 75A Staple Gun - I-3

Suggested Prep Tool721 Multi-Wire Stripper/Cutter - I-9

Conductors Stranded, tinned copper

Insulation PE

Shield Overall Mylar/aluminum foil tape with stranded, tinned copper drain wire

Jacket Gray PVC

Specifi cations

Applications Public address systems, unbalanced intercom systems, interconnecting cables, remote control circuits, recording studios, sound systems, low-voltage relay controls where RF shielding is required.

Some air plenum designs also available.

Part No.

No. of Cond. AWG

Cond. Stranding

Nom. Insulation Thickness (in)

Nom. Jacket Thickness (in)

Nominal O.D. (in)

2C22T70S 2 22 7/30 .010 .032 .175

3C22T70S 3 22 7/30 .010 .032 .185

4C22T70S 4 22 7/30 .010 .032 .200

2C20T100S 2 20 10/30 .016 .032 .225

3C20T100S 3 20 10/30 .016 .032 .230

4C20T100S 4 20 10/30 .016 .032 .250

3C18T160S 3 18 16/30 .018 .028 .240

3C16T190S 3 16 19/29 .030 .030 .325

Audio & Communications

[email protected] 800-238-7514

Page 15: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

15

Twisted Pair Unshielded NEC Type CM®

See referenced pages in the Hardware & Supplies section:

Installation HardwareAcme 25A or 75A Staple Gun - I-3

Suggested Prep Tool721 Multi-Wire Stripper/Cutter - I-9

Conductors Stranded, tinned copper

Insulation PVC

Shield None

Jacket Gray PVC

Specifi cations

Applications Audio, communications, telemetering and instrumentation circuits.

Some air plenum designs also available.

Part No.

No. of Pairs AWG

Cond. Stranding

Nom. Insulation Thickness (in)

Nom. Jacket Thickness (in)

Nominal O.D. (in)

2P22T7NS 2 22 7/30 .015 .030 .260

3P22T7NS 3 22 7/30 .015 .030 .275

4P22T7NS 4 22 7/30 .015 .030 .298

6P22T7NS 6 22 7/30 .010 .030 .320

1P18T16NS 1 18 16/30 .018 .030 .230

2P18T16NS 2 18 16/30 .018 .035 .287

3P18T16NS 3 18 16/30 .018 .035 .330

4P18T16NS 4 18 16/30 .018 .035 .335

5P18T16NS 5 18 16/30 .018 .035 .360

6P18T16NS 6 18 16/30 .018 .035 .440

9P18T16NS 9 18 16/30 .018 .040 .545

Audio & Communications

[email protected] 800-238-7514

Page 16: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

16

One Twisted Pair Shielded NEC® Type CM

Twisted Pair, One Pair Shielded, One Pair Unshielded NEC® Type CM

Applications Special audio, communications and instrumentation uses requiring shielded groups to isolate circuits.

Applications Public address systems, unbalanced intercom systems, interconnecting cables, remote control circuits, low-voltage relay controls where RF shielding is required.

See referenced pages in the Hardware & Supplies section:

Installation HardwareAcme 25A Staple Gun - I-3

Suggested Prep Tools721 Multi-Wire Stripper/Cutter - I-9

See referenced pages in the Hardware & Supplies section:

Installation HardwareAcme 25A or 75A Staple Gun - I-3

Suggested Prep Tool721 Multi-Wire Stripper/Cutter - I-9

Conductors Stranded, tinned copper

Insulation Color-coded polypropylene (2P22) or PE

Shield Mylar/aluminum foil tape with copper drain wire on one pair only

Jacket Gray PVC

Specifi cations

Part No.

No. of Cond. AWG

Cond. Stranding

Nom. Insulation Thickness (in)

Nom. Jacket Thickness (in)

Nominal O.D. (in)

2P22T7PIP0 42-22 shielded

7/30 .010 .02 .1782-22 unshielded

2P20T10PIP0 42-20 shielded

10/30 .015 .025 .2152-20 unshielded

3C20T10PIC0 32-20 shielded

10/30 .015 .028 .2101-20 unshielded

Conductors Stranded, tinned copper

Insulation PE

Shield Overall Mylar/aluminum foil tape with stranded, tinned copper drain wire

Jacket Gray PVC

Specifi cations

Part No.

No. of Pairs AWG

Cond. Stranding

Nom. Insulation Thickness (in)

Nom. Jacket Thickness (in)

Nominal O.D. (in)

1P22T7PS 1 22 7/30 .015 .025 .170

1P20T10PS 1 20 10/30 .015 .025 .185

1P18T16PS 1 18 16/30 .018 .030 .235

1P16T19PS 1 16 19/29 .030 .030 .310

1P14T19PS 1 14 19/27 .032 .035 .350

1P12T19PS 1 12 19/25 .034 .040 .410

Some air plenum designs also available.

Audio & Communications

[email protected] 800-238-7514

Page 17: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

17

Applications Special audio, communications and instrumentation uses requiring shielded groups to isolate circuits.

Twisted Pair Each Pair Individually Shielded NEC® Type CM

See referenced pages in the Hardware & Supplies section:

Installation HardwareAcme 25A, 37A or 75A Staple Gun - I-3

Suggested Prep Tool721 Multi-Wire Stripper/Cutter - I-9

Conductors Stranded, tinned copper

Insulation PE

Shield Mylar/aluminum foil tape with stranded, tinned copper drain wire on one pair only

Jacket Gray PVC

Specifi cations

Part No.

No. of Pairs AWG

Cond. Stranding

Nom. Insulation Thickness (in)

Nom. Jacket Thickness (in)

Nominal O.D. (in)

2P22T7EPS 2 22 7/30 .010 .045 .190

3P22T7EPS 3 22 7/30 .010 .045 .295

6P22T7EPS 6 22 7/30 .010 .045 .375

9P22T7EPS 9 22 7/30 .010 .045 .430

11P22T7EPS 11 22 7/30 .010 .045 .465

12P22T7EPS 12 22 7/30 .010 .045 .480

15P22T7EPS 15 22 7/30 .010 .060 .565

17P22T7EPS 17 22 7/30 .010 .060 .590

19P22T7EPS 19 22 7/30 .010 .060 .620

27P22T7EPS 27 22 7/30 .010 .060 .700

3P20T10EPS 3 20 10/30 .013 .045 .340

6P20T10EPS 6 20 10/30 .013 .045 .435

9P20T10EPS 9 20 10/30 .013 .060 .500

12P20T10EPS 12 20 10/30 .013 .060 .595

15P20T10EPS 15 20 10/30 .013 .060 .655

3P18T16EPS 3 18 16/30 .016 .045 .400

6P18T16EPS 6 18 16/30 .016 .045 .495

9P18T16EPS 9 18 16/30 .016 .060 .590

12P18T16EPS 12 18 16/30 .016 .070 .705

15P18T16EPS 15 18 16/30 .016 .070 .78

Some air plenum designs also available.

Audio & Communications

[email protected] 800-238-7514

Page 18: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

18

Twisted Pair, Direct Earth Burial Each Pair Individually Shielded

For 300V Rated Communications Cable, see pages 10-14 in the IMSA Spec section.

For Air Core Outside Telephone Cable (ideal for low-voltage applications where many conductors/pairs are needed and flexibility is not a critical factor), see pages 2 and 4 in the Outside Telephone section.

Applications Suitable for direct earth burial, outdoor uses.

See referenced pages in the Hardware & Supplies section:

Installation HardwareAcme 75A Staple Gun - I-3

Suggested Prep Tool721 Multi-Wire Stripper/Cutter - I-9

Conductors Stranded, tinned copper

Insulation PE

Shield Mylar/aluminum foil tape with a stranded, tinned copper drain wire on each pair

Jacket Black PE

Specifi cations

Part No.

No. of Pairs AWG

Cond. Stranding

Nom. Insulation Thickness (in)

Nom. Jacket Thickness (in)

Nominal O.D. (in)

3P20T10EPS1 3 20 10/30 .013 .040 .340

6P20T10EPS1 6 20 10/30 .013 .045 .480

1P16T19I502 1 16 19/30 .030 .030 .285

1P14T19I502 1 14 19/27 .030 .030 .340

1P12T19I502 1 12 19/25 .030 .030 .380

Audio & Communications

[email protected] 800-238-7514

Page 19: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

19

Plenum Electronic Cable, Unshielded NEC® 725, Type CMP and/or CL2P UL Classified as to fire and smoke only

Applications Security, audio, intercom, power limited control circuits; for installation through air plenums without metal conduit.

See referenced pages in the Hardware & Supplies section:

Installation HardwareAcme 25A or 75A Staple Gun - I-3

Suggested Prep Tool721 Multi-Wire Stripper/Cutter - I-9

Part No.No. of Cond. AWG

Cond. Description

Nominal O.D. (in)

Weight (lbs/M-ft)

1P22B7NSP 1 pair 22 stranded bare .115 16

4C22B7NSP 4 22 stranded bare .140 25

6C22B7NSP 6 22 stranded bare .160 28

8C22B7NSP 8 22 stranded bare .180 32

10C22B7NSP 10 22 stranded bare .192 40

12C22B7NSP 12 22 stranded bare .220 46

1P18B1NSP 1 pair 18 solid bare .132 22

1P18B7NSP 1 pair 18 stranded bare .145 24

3C18B1NSP 3 18 solid bare .140 28

3C18B7NSP 3 18 stranded bare .155 30

4C18B1NSP 4 18 solid bare .155 35

4C18B7NSP 4 18 stranded bare .175 37

5C18B7NSP 5 18 stranded bare .195 45

6C18B1NSP 6 18 solid bare .215 52

6C18B7NSP 6 18 stranded bare .215 52

8C18B1NSP 8 18 solid bare .230 66

8C18B7NSP 8 18 stranded bare .230 68

10C18B1NSP 10 18 solid bare .280 82

10C18B7NSP 10 18 stranded bare .280 82

1P16B7NSP 1 pair 16 stranded bare .163 25

3C16B19NSP 3 16 stranded bare .185 35

4C16B19NSP 4 16 stranded bare .205 46

1P14B19NSP 1 pair 14 stranded bare .196 40

3C14B19NSP 3 14 stranded bare .240 54

4C14B19NSP 4 14 stranded bare .265 70

1P12B7NSP 1 pair 12 stranded bare .267 60

4C12B7NSP 4 12 stranded bare .410 110

Conductors Solid bare copper, stranded bare copper

Insulation Low smoke-producing, low flame-spread compounds

Jacket Low smoke-producing, low flame-spread approved compounds

Specifi cations

Audio & Communications

[email protected] 800-238-7514

Page 20: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

20

Plenum Electronic Cable, Shielded NEC® 725, Type CMP and/or CL2P UL Classified as to fire and smoke only

Applications Security, audio, intercom, power limited control circuits; for installation through air plenums without metal conduit.

See referenced pages in the Hardware & Supplies section:

Installation HardwareAcme 25A or 75A Staple Gun - I-3

Suggested Prep Tool721 Multi-Wire Stripper/Cutter - I-9

Conductors Solid bare copper or stranded bare copper

Insulation Low smoke-producing, low flame-spread compounds

Shield Overall Mylar/aluminum foil tape with a stranded, tinned copper drain wire

Jacket Low smoke-producing, low flame-spread approved compounds

Specifi cations

Part No.No. of Cond. AWG

Cond. Description

Nominal O.D. (in)

Weight (lbs/M-ft)

1P22B70SP 1 pair 22 stranded bare .110 18

4C22B70SP 4 22 stranded bare .125 22

6C22B70SP 6 22 stranded bare .182 28

8C22B70SP 8 22 stranded bare .199 36

10C22B70SP 10 22 stranded bare .224 42

12C22B70SP 12 22 stranded bare .236 50

1P18B10SP 1 pair 18 solid bare .110 18

1P18B70SP 1 pair 18 stranded bare .150 26

3C18B70SP 3 18 stranded bare .160 34

4C18B70SP 4 18 stranded bare .180 40

6C18B70SP 6 18 stranded bare .220 50

8C18B70SP 8 18 stranded bare .240 70

1P16B70SP 1 pair 16 stranded bare .180 30

4C16B190SP 4 16 stranded bare .215 50

2C14B190SP 2 14 stranded bare .225 46

4C14B190SP 4 14 stranded bare .270 76

Each Pair Shielded:

2P18T7EPSP 2 pair 18 stranded tinned .192 48

Other sizes available upon request.

Audio & Communications

[email protected] 800-238-7514

Page 21: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

21

Category 5E CMR/CMX Indoor/Outdoor

Indoor/Outdoor Station Wire NEC® and UL specifications, UL Listed Type CMX

Part No. 4P24B1CMX5E

Application Demarcation wire.

See referenced pages in the Hardware & Supplies section:

Installation HardwareAcme 25A Staple Gun - I-3

Suggested Prep Tool721 Multi-Wire Stripper/Cutter - I-9

Conductors Solid, soft-drawn annealed bare copper

Insulation High density PE, color-coded

Jacket Flexible gray or beige PVC

Specifi cations

Part No.No. of Cond. AWG

Insulation Thick. (in)

Nominal O.D. (in)

Weight (lbs/M-ft)

4C24B1CMX 4 24 .01 .132 15

2C22B1CMX 2 22 .01 .124 12

3C22B1CMX 3 22 .01 .135 15

4C22B1CMX 4 22 .01 .150 18

5C22B1CMX 5 22 .01 .185 22

Color Ordering ChartPair Colors

1 Blue/White

2 Orange/White

3 Green/White

4 Brown/White

Conductors 24 AWG solid, annealed bare copper

Insulation Polyolefin

Jacket Tough, flame-retardant, weather- and abrasion-resistant PVC

Specifi cations

Part No.No. of Pairs AWG

Insulation Thick. (in)

Nominal O.D. (in)

Weight (lbs/M-ft)

2P22B1CMX 2 22 .01 .185 18

3P22B1CMX 3 22 .01 .200 26

4P22B1CMX 4 22 .01 .235 34

Color Ordering ChartNo. of Cond. Colors

2 Red/Green

3 Red/Green/Yellow

4 Red/Green/Yellow/Black

5 Red/Green/Yellow/Black/White

Audio & Communications

[email protected] 800-238-7514

Page 22: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

22

Plenum Station Wire NEC® and UL® specifications, UL Listed Type CMP

Cross-Connect Wire, PW

Application Demarcation wire used inside the house.

Application Cross-connect termination boxes.

See referenced pages in the Hardware & Supplies section:

Installation HardwareAcme 25A Staple Gun - I-3

Suggested Prep Tools100 Adjustable Wire Stripper/Cutter - I-9

See referenced pages in the Hardware & Supplies section:

Installation HardwareAcme 25A Staple Gun - I-3

Suggested Prep Tools721 Multi-Wire Stripper/Cutter - I-9

Conductors Solid, soft-drawn annealed bare copper

Insulation Low smoke-producing, low flame-spread compounds with cross-reference

Configuration Twisted pairs

Jacket Low smoke-producing, low flame-spread approved compounds

Specifi cations

Part No.No. of Pairs AWG

Nominal O.D. (in)

Weight (lbs/M-ft)

1P24B1PW 1 24 0.08 5

2P24B1PW 2 24 0.13 8

3P24B1PW 3 24 0.16 12

Conductors Solid, soft-drawn annealed bare copper

Configuration Non-jacketed twisted pairs

Jacket Solid, semi-rigid PVC with cross-reference band-marked color code

Specifi cations

Part No.No. of Cond. AWG

Insulation Thick. (in)

Nominal O.D. (in)

Weight (lbs/M-ft)

4C24B1CMP 4 24 .1 .132 12

2C22B1CMP 2 22 .1 .124 12

4C22B1CMP 4 22 .1 .145 20

Color Ordering ChartNo. of Cond. Colors

2 Red/Green

4 Red/Green/Yellow/Black

Voice, Video Data & Broadband

[email protected] 800-238-7514

Page 23: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

23

Specifications Connectorized cables save installation time by minimizing on-the-job terminating and cable splicing. Pre-tested, factory-assembled connectorized cables also minimize installation terminating and splicing mistakes.

Connectorized Inside Telephone Type CM

Type designations:

Type PX: Plug on one end

Type CX: Connector on one end

Type PC: Plug on one end, connector on other end

Type PP: Plug on both ends

Type CC: Connector on both ends

•••••

6-pair

12-pair

25-pair

50-pair

••••

75-pair

100-pair

200-pair

•••

Standard connectorized cable sizes

5'

10'

15'

20'

25'

•••••

30'

50'

75'

100'

125'

•••••

150'

175'

200'

250'

••••

Standard lengths Custom made to your requirements

Configuration 25-pair plugs (P = male) and/or 25-pair connectors (C = female) on one or both ends. On 50-pair and larger cables, the cable ends are divided into 25-pair sub-units, to which the 25-pair plugs/connectors are applied.

Voice, Video Data & Broadband

[email protected] 800-238-7514

Page 24: Coaxial Cable, PVC/PE - Power & Tel Info/voice-video... · Coaxial Cable, PVC/PE Part No. Description AWG Conductor Shield Ohms Jacket Nominal O.D. (in) Weight (lbs/M-ft) 1C22W162AU1

Notes

24

Voice, Video Data & Broadband

[email protected] 800-238-7514