coaxial cable, pvc/pe - power & tel info/voice-video... · coaxial cable, pvc/pe part no....
TRANSCRIPT
1
CCTV and Camera Cable Security and Alarm
Coaxial Cable, PVC/PE
Part No. Description AWG Conductor Shield Ohms JacketNominal O.D. (in)
Weight (lbs/M-ft)
1C22W162AU1 RG-62 IBM 22 Solid CCS 95% BC Braid 93 PVC .242 38
1C22W162AU2 RG-62 Outdoor 22 Solid CCS 95% BC Braid 93 PVC .260 40
1C22W159U RG-59 22 Solid CCS 70% BC Braid 73 PVC .242 36
1C22W159U1 RG-59 22 Solid CCS 95% BC Braid 75 PVC .242 40
1C20W159U1 RG-59 Outdoor, Sunlight Resistant
20 Solid CCS 95% BC Braid 75 PVC .242 40
1C20W159U3 RG-59 20 Solid CCS 80% BC Braid 75 PVC .242 30
1C20B159U1 RG-59 20 Solid BC 95% BC Braid 75 PVC .242 34
120W159U1DBRG-59 Outdoor Direct Burial
20 Solid CCS 95% BC Braid 75 PE .239 35
120B159U1DBRG-59 Outdoor Direct Burial
20 Solid BC 95% BC Braid 75 PE .242 36
2C22W159U RG-59 Dual Wang 22 Solid CCS 95% BC Braid 75 PVC .238 x .478 84
1C20B158U RG-58 20 Solid BC 95% TC Braid 51.5 PVC .195 30
1C20T1958AU RG-58 20 Stranded TC 95% TC Braid 50 PVC .193 30
1C20T19NET RG-58 Thin Net 20 Stranded TC Foil + 93% TC Braid 50 PVC .185 26
1C20B158U2 RG-58 Outdoor 20 Solid BC 95% TC Braid 55 PE .195 34
1C11B78U1 RG-8 11 Stranded BC 97% BC Braid 50 PVC .403 112
1C18B1NET RG-6 18 Solid BC Foil + 60% TC Braid 75 PVC .275 40
1P20X7TWAXS Twinax 20 Stranded 1-TC, 1-BC Foil + 90% TC Braid 100 PVC .33070
1P20X7TWAX1 Twinax Outdoor 20 Stranded 1-TC, 1-BC 85% TC Braid 100 PE .330 72
2C20T7TWAX1 Blue Hose 20 Stranded TC Foil + 57% TC Braid 78 PVC .243 39
Part No. Description AWG Conductor Shield Ohms JacketNominal O.D. (in)
Weight (lbs/M-ft)
1C22B759U RG-59 - CCTV 22 Stranded BC 95% BC Braid 76 PVC .242 45
1C14B111U RG-11 - CCTV 14 Solid BC 95% BC Braid 75 PVC .405 90
1C18B16U4 RG-6 - CCTV 18 Solid BC 95% BC Braid 75 PVC .270 36
3C22X759U Siamese
RG-59 Control Pair 22 AWG
22Stranded BC with 1 pr. 22 Shielded
Foil on Pair 95% BC Braid
76 PVC .242 x .445 75
Coaxial Cable
[email protected] 800-238-7514
2
Coaxial Cable, Plenum
Coaxial Cable, ArmoredArmored coaxial cable features PVC inner and outer jackets with corrugated aluminum armor between.
Part No. Description AWG Conductor Shield OhmsNom. O.D.
(in)Weight
(lbs/M-ft)
1C22W162AUP RG-62 22 Solid CCS 96% BC Braid 93 .200 40
1C22W1IBMP RG-62 IBM 22 Solid CCS 96% BC Braid 93 .200 42
1C20W159UP RG-59 20 Solid CCS 95% BC Braid 75 .196 36
2C22W159USP RG-59 Dual Wang 22 Solid CCS 97% BC Braid 75 .212 x .424 98
1C20B158UP RG-58 20 Solid BC 95% TC Braid 53.5 .161 35
1C14B111UP RG-11 14 Solid BC Foil + 95% TC Braid 75 .352 115
1C18B16UP1 RG-6 18 Solid BC Foil + 95% TC Braid 75 .240 44
1C18B16UP RG-6 18 Solid BC 95% BC Braid 75 .228 43
1C20B159UP RG-59 20 Solid BC 95% BC Braid 75 .193 31
1C12B1NETP Ethernet 12 Solid BC Foil + 90% TC Braid 50 .247148
1C20T19NETP Thin Net 20 Stranded TC Foil + 93% TC Braid 50 .165 30
1P20X7TWAXP Twinax 20 Stranded 1-TC, 1-BC Foil + 85% TC Braid 100 .26745
3C22X759UP Siamese 221 pr. 22 AWG Stranded TC, Stranded BC
Pair Shielded 95% TC Braid
75 .210 x .359 45
Part No. Description AWG Conductor Shield Ohms JacketNom. O.D.
(in)Weight
(lbs/M-ft)
2C20T7TWAXA Blue Hose 20 Stranded TC Foil + 55% TC Braid 78 PVC .563 122
Coaxial Cable
[email protected] 800-238-7514
3
Broadband Coaxial CATV
Recommendations
11/u for distances over 175'
6/u for distances to 175'
59/u minimum capacity requirements
•••
See referenced pages in the Hardware & Supplies section:
Installation HardwareAcme 37AC Staple Gun - I-3
Suggested Prep ToolUniversal Drop Trimmer - I-9
•
•
Table courtesy of Belden.
Note: Attenuation numbers are valid at 68°F (20°C)
Series 11Series 6Series 59Freq. (MHz)
Nom Atten. dB/100'
Max. Atten. dB/100'
Nom Atten. dB/100'
Max. Atten. dB/100'
Nom Atten. dB/100'
Max. Atten. dB/100'
Attenuation Values for Broadband Cables
5 0.55 0.58 0.42 0.45 0.26 0.29
55 1.83 1.95 1.42 1.53 0.89 0.97
211 3.61 3.82 2.79 3.02 1.74 1.92
216 3.66 3.87 2.83 3.06 1.76 1.95
240 3.86 4.09 2.99 3.23 1.86 2.06
270 4.10 4.35 3.17 3.44 1.98 2.19
300 4.33 4.58 3.35 3.64 2.09 2.32
325 4.51 4.78 3.49 3.79 2.18 2.42
350 4.69 4.96 3.63 3.93 2.28 2.51
375 4.85 5.14 3.76 4.08 2.36 2.61
400 5.02 5.31 3.89 4.21 2.44 2.70
450 5.33 5.64 4.13 4.47 2.60 2.86
500 5.62 5.95 4.36 4.72 2.74 3.03
550 5.90 6.25 4.57 4.95 2.88 3.18
600 6.17 6.54 4.78 5.18 3.02 3.33
650 6.45 6.83 4.97 5.41 3.14 3.47
700 6.73 7.13 5.17 5.63 3.27 3.61
750 6.97 7.39 5.35 5.83 3.39 3.74
800 7.20 7.64 5.54 6.03 3.51 3.87
862 7.48 7.94 5.75 6.27 3.64 4.02
870 7.52 7.98 5.78 6.30 3.66 4.04
900 7.66 8.12 5.89 6.41 3.73 4.11
950 7.87 8.35 6.05 6.60 3.84 4.23
1000 8.09 8.58 6.22 6.78 3.94 4.35
Part No. Description AWG Conductor Shield Jacket Nom. O.D. (in) Weight (lbs/M-ft)
CATV Drop - 75 Ohm, for interior horizontal, lashed outdoor aerial drop and conduit installation
1C20W15967 RG-59 20 Solid CCS Foil + 67% Alum. Braid PVC .240 28
1C18W1660 RG-6 18 Solid CCS Foil + 60% Alum. Braid PVC .272 33
1C18W1QUAD6 RG-6 Quad Shield 18 Solid CCSFoil + 60% Alum. Braid Tape + 42% Alum. Braid
PVC .300 38
1C14W11160 RG-11 14 Solid CCS Foil + 60% Alum. Braid PVC .395 65
1C14W1QD11 RG-11 Quad Shield 14 Solid CCSFoil + 60% Alum. Braid Tape + 40% Alum. Braid
PVC .405 77
CATV Drop Flooded - 75 Ohm, for underground installation
1C20W159F57 RG-59 20 Solid CCS Foil + 67% Alum. Braid PE .240 24
1C18W16F60 RG-6 18 Solid CCS Foil + 60% Alum. Braid PE .272 33
1C18W1Q6F RG-6 Quad Shield 18 Solid CCSFoil + 60% Alum. Braid Tape + 40% Alum. Braid
PE .272 45
1C14W111F60 RG-11 14 Solid CCS Foil + 60% Alum. Braid PE .395 60
1C14W1Q11F RG-11 Quad Shield 14 Solid CCSFoil + 60% Alum. Braid Tape + 40% Alum. Braid
PE .395 58
CATV Self-Supporting Figure-8 - 75 Ohm
1C20W159M67RG-59 .051" messenger
20 Solid CCS Foil + 67% Alum. Braid PVC .240 45
1C18W16M60RG-6 .051" messenger
18 Solid CCS Foil + 60% Alum. Braid PVC .272 48
1C14W111M60RG-11 .072" messenger
14 Solid CCS Foil + 60% Alum. Braid PVC .395 99
Coaxial Cable
[email protected] 800-238-7514
4
Siamese Coaxial CableAvailable with either dual coaxial cables or coaxial cable with a twisted
pair and also in a plenum-rated design for installation in a drop ceiling or a raised floor.
These cables are easier to install than standard coaxial cables and are ideal for dual Direct Broadcast System (DBS) applications where one dish is used to serve two receivers. They also are critical for satellite hookup where a powered-pair cable is desired. Other applications for these coaxial cables include sound and security surveillance cameras where the coaxial cable transmits the audio/video signal and the twisted pair is used to control the pan and tilt function of the closed-circuit television (CCTV) camera.
In today’s uncertain world, security installations are occurring at a double-digit growth rate. Security cameras are being installed in virtually every office, school and government facility, on highways and in traffic control centers as well as in most industrial, commercial and manufactur-ing facilities.
See referenced pages in the Hardware & Supplies section:
Installation HardwareCollapsible Cable Caddy - I-3
Suggested Prep ToolsDrop Cable Slitter DCS - H-7Coaxial Cable Cutter - I-5Universal Drop Trimmer - I-9
•
•••
Part No. Description AWG Conductor Shield Ohms Jacket
Nom. O.D. (in)
Weight (lbs/M-ft)
2C18WI6DUAL RG-6 - CATV 18 Solid CCS Foil + 60% Alum. Braid 75 PVC .270 x .595 60
3C18B1RG6U RG-6 - CATV 18 Solid BCFoil + 95% TC Pair 18 Stranded Unshielded
75 PVC .270 x .493 78
2C20W159US RG-59 - Dual CATV 20 Solid CCS Foil + 67% Alum. Braid 75 PVC .242 x .498 60
3C22X759U RG-59 - CATV 22 Stranded BC 95% BC with Foil on 76 PVC .242 x .445 75
3C20X159U1 RG-59 - CATV 20 Solid BC 95% BC 75 PVC .238 x .440 75
3C20B059UP RG-59 - CMP 20 Solid BC 95% BC 75 Plenum .200 x .383 53
Coaxial Cable
[email protected] 800-238-7514
5
By installing a single composite cable throughout the Intelligent Home, Residential cable means that every room is already wired for:
Analog or digital cable and satellite television
Cable modem service
Multiple telephone lines
High-speed Internet access
Video monitors and security systems
Lighting and energy management systems
Networked audio from stereos and home theater systems
Home office systems
Shared access to home entertainment components such as DVDs, VCRs and CD players
Networked computer peripherals such as printers and scanners, with high-speed Ethernet capabilities
•••••••••
•
Multimedia Cable Delivers the Future Multimedia products include broadband coaxial cables and data cables – and, in some configurations, fiber optic cables – IN A SINGLE JACKET. They allow you to install plug-and-play points throughout the home for TV, multimedia, data and telephone communications.
VERIFIED
Green, Flame-retardant, PVC, .625" Part No. 20C0X07878A
Same as above, plus:One 2-fiber LANLite® Distribution Cable
Gigabit ethernet-grade fiber 62.5/125/900 Micron tight buffered fiber
Other constructions available, call for more information.
Green, Flame-retardant, PVC, .6" Part No. 18C0X07876A
Two Series 6 coaxial cables Duobond Plus Series 6 (solid copper conductor) Duobond Plus (Bonded Tri-shield) + 80% Braid, swept to 2.25 GHz Two Cat 5E 4 pair bonded UTP cables UTP verified (UL) to Category 5E 24 AWG solid bare copper, polyolefin insulation
See referenced pages in the Hardware & Supplies section:
Suggested Prep ToolsMK01A Multi-wire Stripper/Cutter - I-11SDT 596-250 Single Drop Trimmer - I-9 For the RG-6 series cables. A CAT tool (Compression Assembly Tool) or Hex Crimp Tool is needed for installing the RG-6 cable. This tool is dependent on the style of connector being used on the cable. It will be either a Hex Crimp- or Compression-style connector 103-S Fiber Optic Stripper - I-10 For the 62.5/125/900 Micron tight buffered fiber.
•
•
•
Data Communications
[email protected] 800-238-7514
6
Multimedia Banana Peel® Cable Cable solutions from Belden for home automation, networking, security and entertainment systems.
The overall jacket has been eliminated to make Banana Peel® cables easy to identify, easy to pull and easy to terminate.
VERIFIED
Benefits
Patent-pending design affixes the individual cables to a center spline, eliminating the need for an overall jacket
Cables have a smaller O.D. than traditional composite cables, improv-ing the cable's overall bend radius for faster, easier installation
Individual data, coax and fiber cable components are all instantly identifiable and ready for termination - just peel the individual cables off the center spline
Verified Category 5E Performance
Available in two configurations:
2 x 2 (two data cables, two coaxes)
2 x 2 x 2 (two data cables, two coaxes and two fibers)
All are rated CMR/C (UL) CMG FT4, and all come standard on 500' and 1,000' reels.
Banana Peel® cables include:
Belden 7876S — Two Cat 5E 4-pair bonded UTP data cables, plus two Series 6 Duobond Plus® coaxial cables
Belden 7878S — Two Cat 5E 4-pair bonded UTP data cables, plus two Series 6 Duobond Plus® coaxes and one 2-fiber LANLite® distribution cable
Belden 7913S — Two Cat 5E 4-pair UTP data cables, plus two Series 6 Duobond IV Quad Shield® coaxes
Belden 7914S — Two Cat 5E 4-pair UTP cables, plus two Series 6 Duobond IV Quad Shield® coaxes and one 2-fiber LANLite® distribu-tion cable.
•
•
•
•
••
•
•
•
•
Data Communications
Data Communications
[email protected] 800-238-7514
7
Category 6E Twisted Pair Data Cables CMR/CMPStandard Compliances
ANSI/TIA/EIA-568-B.2-1 (Category 6)ANSI/TIA/EIA-862 (Building Automation)ISO/IEC 11801 Ed. 2.0 (Class E)ICEA S-102-700 (Category 6)UL and c(UL) Type CMR (UL 1666) for Non-PlenumUL and c(UL) Type CMP (NFPA 262) for PlenumUL 444
Applications
IEEE 802.3: 1000BASE-T (Gigabit Ethernet), 100BASE-TX, 10BASE-TANSI/TIA/EIA-854: 1000BASE-TX155 Mp/s, 1.2 Gb/s ATMANSI X3.263: 100Mb/sIEEE 802.3af DTE Power (POE)4/16 Mb/s Token RingDigital VideoBroadband and Baseband analog video
•••••••
•
•••••••
Part No. 4P23B1CMR6E – Non-PlenumPart No. 4P23B1CMP6E – Plenum
Note: Values are expressed in dB per 100m (328 ft) length.
See referenced pages in the Hardware & Supplies section:
Installation HardwareAcme 25AC Staple Gun - I-3
Suggested Prep ToolsSMART-STRIP Stripper - I-11Universal Drop Trimmer - I-9
•
••
Frequency MHz
PSACR min.
ACR min.
Attenuation max.
PSNEXT min.
NEXT min.
PSELFEXT min.
ELFEXT min.
Return Loss min.
LCL min. ELTCTL
1 74.3 76.3 2 76.3 78.3 71.8 74.8 20 50 35
4 63.6 65.6 3.7 67.3 69.3 59.7 62.7 23 44 23
10 55.5 57.5 5.8 61.3 63.3 51.8 54.8 25 40 15
16 50.8 52.8 7.4 58.2 60.2 47.7 50.7 25 38 10.9
20 48.5 50.5 8.3 56.8 58.8 45.7 48.7 25 37 9
31.25 43.4 45.4 10.5 53.9 55.9 41.9 44.9 23.6 35.1 5.1
62.5 34.3 36.3 15.1 49.4 51.4 35.8 38.8 21.5 32 -
100 26.9 28.9 19.4 46.3 48.3 31.8 34.8 20.1 30 -
200 13.4 15.4 28.4 41.8 43.8 25.7 28.7 18 27 -
250 8.1 10.1 32.2 40.3 42.3 23.8 26.8 17.3 26 -
300 3.4 5.4 35.7 39.1 41.1 22.2 25.2 16.8 25.2 -
350 - 1.1 39 38.1 40.1 20.9 23.9 16.3 24.6 -
400 - - 42.1 37.3 39.3 19.7 22.7 15.9 24 -
500 - - 48 35.8 37.8 17.8 20.8 15.2 23 -
Electrical Performance (typical)
Data Communications
[email protected] 800-238-7514
8
Category 6 Twisted Pair Data Cables Unshielded Twisted Pair (UTP) CMR/CMPStandard Compliances
ANSI/TIA/EIA-568-B.2-1 (Category 6)
ANSI/TIA/EIA-862 (Building Automation)
ISO/IEC 11801 Ed. 2.0 (Class E)
ICEA S-102-700 (Category 6)
UL and c(UL) Type CMR (UL 1666) for Non-Plenum
UL and c(UL) Type CMP (NFPA 262) for Plenum
UL 444
Applications
IEEE 802.3: 1000BASE-T (Gigabit Ethernet), 100BASE-TX, 10BASE-T
ANSI/TIA/EIA-854: 1000BASE-TX
155 Mp/s, 1.2 Gb/s ATM
ANSI X3.263: 100Mb/s
IEEE 802.3af DTE Power (POE)
4/16 Mb/s Token Ring
Digital Video
Broadband and Baseband analog video
Part No. 4P23B1CMR6 – Non-PlenumPart No. 4P23B1CMP6 – Plenum
•••••••
•
•••••••
Note: Values are expressed in dB per 100m (328 ft) length.
See referenced pages in the Hardware & Supplies section:
Installation HardwareAcme 25AC Staple Gun - I-3
Suggested Prep ToolsSMART-STRIP Stripper - I-11Universal Drop Trimmer - I-9
•
••
Frequency MHz
PSACR min.
ACR min.
Attenuation max.
PSNEXT min.
NEXT min.
PSELFEXT min.
ELFEXT min.
Return Loss min.
LCL min. ELTCTL
1 71.3 73.3 2.0 73.3 75.3 65.8 68.8 20.0 50.0 35.0
4 60.5 62.5 3.8 64.3 66.3 53.8 56.8 23.0 44.0 23.0
10 52.4 54.4 5.9 58.3 60.3 45.8 48.8 25.0 40.0 15.0
16 47.7 49.7 7.5 55.3 57.3 41.7 44.7 25.0 38.0 10.9
20 45.4 47.4 8.4 53.8 55.8 39.8 42.8 25.0 37.0 9.0
31.25 40.3 42.3 10.6 50.9 52.9 37.8 38.9 23.6 35.1 5.1
62.5 31.1 33.1 15.3 46.4 48.4 29.9 32.9 21.5 32.0 -
100 23.6 25.6 19.7 43.3 45.3 25.8 28.8 20.1 30.0 -
200 9.9 11.9 28.8 38.8 40.8 19.8 22.8 18.0 27.0 -
250 4.6 6.6 32.7 37.3 39.3 17.8 20.8 17.3 26.0 -
350 - 2.0 39.6 35.2 37.2 - - - 24.6 -
400 - - 42.7 34.3 36.3 - - - 24.0 -
500 - - 48.7 32.8 34.8 - - - 23.0 -
Electrical Performance (typical)
Data Communications
[email protected] 800-238-7514
9
Standard Compliances
ANSI/TIA/EIA-568-B.2 (Category 5E)
ANSI/TIA/EIA-862 (Building Automation)
ISO/IEC 11801 Ed. 2.0 (Class D)
ICEA S-90-661 (Category 5E)
UL and c(UL) Type CMR (UL 1666) for Non-Plenum
UL and c(UL) Type CMP (NFPA 262) for Plenum
UL 444
Applications
IEEE 802.3: 1000BASE-T (Gigabit Ethernet)
100BASE-TX, 10BASE-T
155 Mp/s, 622 Mp/s ATM
ANSI X3.263: 100Mb/s
4/16 Mb/s Token Ring
Broadband and Baseband analog video
Part No. 4P24B1CT5EE – Non-PlenumPart No. 4P24B1C5EEP – Plenum
•••••••
••••••
Category 5E Enhanced Twisted Pair Data Cables Unshielded Twisted Pair (UTP) CMR/CMP
Note: Values are expressed in dB per 100m (328 ft) length.
See referenced pages in the Hardware & Supplies section:
Installation HardwareAcme 25AC Staple Gun - I-3
Suggested Prep ToolsSMART-STRIP Stripper - I-11Universal Drop Trimmer - I-9
•
••
Frequency MHz
PSACR min.
ACR min.
Attenuation max.
PSNEXT min.
NEXT min.
PSELFEXT min.
ELFEXT min.
Return Loss min.
1 68.1 70.1 1.9 68.3 70.3 62.0 65.0 20.0
4 57.1 59.1 3.9 59.3 61.3 50.0 53.0 23.0
10 48.9 50.9 6.1 53.3 55.3 42.0 45.0 25.0
16 44.1 46.1 7.8 50.3 52.3 37.9 40.9 25.0
20 41.7 43.7 8.8 48.8 50.8 36.0 39.0 25.0
31.25 36.4 38.4 11.2 45.9 47.9 32.1 35.1 23.6
62.5 26.9 28.9 16.2 41.4 43.4 26.1 29.1 21.5
100 19.0 21.0 21.0 38.3 40.3 22.0 25.0 20.1
155 10.3 12.3 26.8 35.5 37.5 18.2 21.2 18.8
200 4.5 6.5 31.0 33.8 35.8 16.0 19.0 18.0
250 - 0.8 35.3 32.3 34.3 14.0 17.0 17.3
300 - - 39.2 31.2 33.2 12.5 15.5 16.8
350 - - 43.0 30.2 32.2 11.1 14.1 16.3
Electrical Performance (typical)
Data Communications
[email protected] 800-238-7514
10
Category 5E Twisted Pair Data Cables Unshielded Twisted Pair (UTP) CMR/CMP, 100 MbpsStandard Compliances
ANSI/TIA/EIA-568-B.2 (Category 5E)
ANSI/TIA/EIA-862 (Building Automation)
ISO/IEC 11801 Ed. 2.0 (Class D)
ICEA S-90-661 (Category 5E)
UL and c(UL) Type CMR (UL 1666) for Non-Plenum
UL and c(UL) Type CMP (NFPA 262) for Plenum
UL 444
Applications
IEEE 802.3: 1000BASE-T (Gigabit Ethernet); 100BASE-TX, 10BASE-T
52/155 Mp/s ATM
ANSI X3.263: 100Mb/s
4/16 Mb/s Token Ring
Part No. 4P24B1CT5E1 White – Non-Plenum Part No. 4P24B1CT5E4 Blue – Non-Plenum*
Part No. 4P24B1CMS5E – Shielded
Part No. 25P24B1CAT5E – Non-PlenumPart No. 25P24B1CMP5E – Plenum
*Other colors available upon request.
•••••••
••••
Note: Values are expressed in dB per 100m (328 ft) length.
See referenced pages in the Hardware & Supplies section:
Installation HardwareAcme 25AC Staple Gun - I-3
Suggested Prep ToolsSMART-STRIP Stripper - I-11Universal Drop Trimmer - I-9
•
••
Frequency MHz
PSACR min.
ACR min.
Attenuation max.
PSNEXT min.
NEXT min.
PSELFEXT min.
ELFEXT min.
Return Loss min.
1 60.3 63.3 2.0 62.3 65.3 60.8 63.8 20.0
4 49.2 52.2 4.1 53.3 56.3 48.7 51.7 23.0
10 40.8 43.8 6.5 47.3 50.3 40.8 43.8 25.0
16 36.0 39.0 8.2 44.2 47.2 36.7 39.7 25.0
20 33.5 36.5 9.3 42.8 45.8 34.7 37.7 25.0
25 30.9 33.9 10.4 41.3 44.3 32.8 35.8 24.3
31.25 28.2 31.2 11.7 39.9 42.9 30.9 33.9 23.6
62.5 18.4 21.4 17.0 35.4 38.4 24.8 27.8 21.5
100 10.3 13.3 22.0 32.3 35.3 20.8 23.8 20.1
155 1.4 4.4 28.1 29.4 32.4 16.9 19.9 -
200 - - 32.4 27.8 30.8 14.7 17.7 -
250 - - 36.9 26.3 29.3 12.8 15.8 -
Electrical Performance (typical)
Data Communications
[email protected] 800-238-7514
11
Cat 5 & 5E Direct Burial Cables Non-Gopher and Gopher Resistant
Applications Provides extension of the LAN beyond the premises; various constructions meet many environmental needs.
4 or 16 Mbps Token ring (IEEE 802.5)
100 Mbps (ANSI X 3T9.5 TPDDI)
155 Mbps ATM systems designed for Cat 5
Meets Category 5 Transmission requirements of TIA/EIA 568A for horizontal cable
10 Mbps Ethernet (IEEE 802.3)
••••
•
Category 3 Twisted Pair Data Cables
Application Low-speed data, premises phone wiring.
Suitable for IEEE 802.3, 10 BASE T, 10 Mbps
Suitable for IEEE 802.5 16 Mbps Token Ring in limited applications
Meets TIA/EIA 568 Category 3 and NEMA Standard Requirements
••
•
*Shield types: A = Aluminum TapeG = Copper-clad Armor for rodent resistance
See referenced page in the Hardware & Supplies section:
Suggested Prep ToolsSMART-STRIP Stripper - I-11•
See referenced page in the Hardware & Supplies section:
Suggested Prep ToolsSMART-STRIP Stripper - I-11•
Conductors 24 AWG
Insulation PE
Configuration Twisted Pairs
Jacket Black PE; water and UV resistant
Specifi cations
Part No. Pairs O.D. (in)Weight
(lbs/M-ft)
4P24B1C5E0 Unshielded
4 .31 52
4P24B1CT5EA* 4 .31 52
4P24B1CT5EG* 4 .33 68
25P24B1CM5A* 25 .63 250
25P24B1CM5G* 25 .67 285
Conductors 24 AWG solid bare copper
Insulation PE or FEP
Configuration Twisted pairs, unshielded
Jacket PVC or Plenum
Specifi cations
Part No. Pairs Jacket O.D. (in)Weight
(lbs/M-ft)
2P24B1CMR3 2 PVC .130 12
2P24B1CMP3 2 Plenum .130 12
3P24B1CMR3 3 PVC .140 16
3P24B1CMP3 3 Plenum .140 14
4P24B1CMR3 4 PVC .152 20
4P24B1CMP3 4 Plenum .160 18
6P24B1CMR3 6 PVC .185 28
6P24B1CMP3 6 Plenum .185 26
12P24B1CMR3 12 PVC .240 50
12P24B1CMP3 12 Plenum .245 52
25P24B1CMR3 25 PVC .345 115
25P24B1CMP3 25 Plenum .330 106
32P24B1CMR3 32 PVC .360 150
50P24B1CMR3 50 PVC .450 190
50P24B1CMP3 50 Plenum .460 240
100P24B1CMR3 100 PVC .650 450
100P24B1CMP3 100 Plenum .640 460
200P24B1CMR3 200 PVC 1.02 724
200P24B1CMP3 200 Plenum 1.10 728
4P24B1CT5EG
Data Communications
[email protected] 800-238-7514
12
Twisted Pair Plenum Each Pair Individually Shielded NEC® 725 Type CMP
See referenced pages in the Hardware & Supplies section:
Installation HardwareAcme 25AC Staple Gun - I-3
Suggested Prep Tool721 Multi-Wire Stripper/Cutter - I-9
•
•
Applications Special audio, communications and instrumentation uses requiring shielded groups to isolate circuits.
Conductors Stranded, tinned copper
Insulation Low smoke-producing, low flame-spread compounds with cross-reference
Shield Mylar/aluminum foil tape shields on each pair with common 24 AWG stranded tinned copper drain wire
Configuration Twisted pairs, color-coded
Jacket Low smoke-producing, low flame-spread approved compounds
Specifi cations
Part No. No. PairNominal O.D. (in)
Weight (lbs/M-ft) Color Code
2P22T7EPSP 2 .174 33Pair 1: Red/Black Pair 2: Black/White
3P22T7EPSP 3 .241 52Pair 1: Red/Black Pair 2: Black/White Pair 3: Black/Green
6P22T7EPSP 6 .346 90
Pair 1: Red/Black Pair 2: Black/White Pair 3: Black/Green Pair 4: Black/Blue Pair 5: Black/Yellow Pair 6: Black/Brown
Data Communications
[email protected] 800-238-7514
13
Applications Public address systems, intercom systems, interconnecting cables, remote control circuits, low-voltage relay controls where RF shielding is not required.
Straight Conductor Unshielded NEC® Type CM
See referenced pages in the Hardware & Supplies section:
Installation HardwareAcme 25AC Staple Gun - I-3
Suggested Prep Tools100 Adjustable Wire Stripper/Cutter - I-9721 Multi-Wire Stripper/Cutter - I-9
•
•
•
Some air plenum designs also available.
Part No.No. of Cond. AWG
Cond. Stranding
Nom. Insulation
Thickness (in)Nom. Jacket
Thickness (in)Nominal O.D. (in)
2C22T7NS 2 22 7/30 .010 .030 .165
3C22T7NS 3 22 7/30 .010 .030 .170
4C22T7NS 4 22 7/30 .010 .030 .180
5C22T7NS 5 22 7/30 .010 .030 .195
6C22T7NS 6 22 7/30 .010 .030 .210
7C22T7NS 7 22 7/30 .010 .030 .210
8C22T7NS 8 22 7/30 .010 .030 .230
9C22T7NS 9 22 7/30 .010 .030 .245
10C22T7NS 10 22 7/30 .010 .030 .265
12C22T7NS 12 22 7/30 .010 .030 .270
15C22T7NS 15 22 7/30 .010 .030 .290
18C22T7NS 18 22 7/30 .010 .030 .315
20C22T7NS 20 22 7/30 .010 .030 .330
25C22T7NS 25 22 7/30 .010 .030 .365
30C22T7NS 30 22 7/30 .010 .030 .400
40C22T7NS 40 22 7/30 .010 .040 .450
50C22T7NS 50 22 7/30 .010 .040 .500
2C20T10NS 2 20 10/30 .015 .030 .200
3C20T10NS 3 20 10/30 .015 .030 .210
4C20T10NS 4 20 10/30 .015 .030 .230
5C20T10NS 5 20 10/30 .015 .030 .256
7C20T10NS 7 20 10/30 .015 .030 .270
9C20T10NS 9 20 10/30 .015 .030 .320
12C20T10NS 12 20 10/30 .015 .035 .350
15C20T10NS 15 20 10/30 .015 .040 .405
2C18T16NS 2 18 16/30 .018 .030 .230
3C18T16NS 3 18 16/30 .018 .030 .245
4C18T16NS 4 18 16/30 .018 .030 .265
5C18T16NS 5 18 16/30 .018 .037 .300
7C18T16NS 7 18 16/30 .018 .037 .324
9C18T16NS 9 18 16/30 .018 .037 .379
12C18T16NS 12 18 16/30 .018 .040 .430
15C18T16NS 15 18 16/30 .018 .045 .485
19C18T16NS 19 18 16/30 .018 .045 .510
25C18T16NS 25 18 16/30 .018 .060 .625
2C16T26NS 2 16 19/29 .020 .030 .265
3C16T26NS 3 16 19/29 .020 .030 .280
4C16T19NS 4 16 19/29 .030 .045 .375
2C14T19NS 2 14 19/27 .030 .030 .335
2C12T19NS 2 12 65/30 .030 .030 .375
Conductors Stranded, tinned copper
Insulation PVC
Shield None
Jacket Gray PVC
Specifi cations
Audio & Communications
[email protected] 800-238-7514
14
Straight Conductor Shielded NEC® Type CL2 or CM
See referenced pages in the Hardware & Supplies section:
Installation HardwareAcme 25A or 75A Staple Gun - I-3
Suggested Prep Tool721 Multi-Wire Stripper/Cutter - I-9
•
•
Conductors Stranded, tinned copper
Insulation PE
Shield Overall Mylar/aluminum foil tape with stranded, tinned copper drain wire
Jacket Gray PVC
Specifi cations
Applications Public address systems, unbalanced intercom systems, interconnecting cables, remote control circuits, recording studios, sound systems, low-voltage relay controls where RF shielding is required.
Some air plenum designs also available.
Part No.
No. of Cond. AWG
Cond. Stranding
Nom. Insulation Thickness (in)
Nom. Jacket Thickness (in)
Nominal O.D. (in)
2C22T70S 2 22 7/30 .010 .032 .175
3C22T70S 3 22 7/30 .010 .032 .185
4C22T70S 4 22 7/30 .010 .032 .200
2C20T100S 2 20 10/30 .016 .032 .225
3C20T100S 3 20 10/30 .016 .032 .230
4C20T100S 4 20 10/30 .016 .032 .250
3C18T160S 3 18 16/30 .018 .028 .240
3C16T190S 3 16 19/29 .030 .030 .325
Audio & Communications
[email protected] 800-238-7514
15
Twisted Pair Unshielded NEC Type CM®
See referenced pages in the Hardware & Supplies section:
Installation HardwareAcme 25A or 75A Staple Gun - I-3
Suggested Prep Tool721 Multi-Wire Stripper/Cutter - I-9
•
•
Conductors Stranded, tinned copper
Insulation PVC
Shield None
Jacket Gray PVC
Specifi cations
Applications Audio, communications, telemetering and instrumentation circuits.
Some air plenum designs also available.
Part No.
No. of Pairs AWG
Cond. Stranding
Nom. Insulation Thickness (in)
Nom. Jacket Thickness (in)
Nominal O.D. (in)
2P22T7NS 2 22 7/30 .015 .030 .260
3P22T7NS 3 22 7/30 .015 .030 .275
4P22T7NS 4 22 7/30 .015 .030 .298
6P22T7NS 6 22 7/30 .010 .030 .320
1P18T16NS 1 18 16/30 .018 .030 .230
2P18T16NS 2 18 16/30 .018 .035 .287
3P18T16NS 3 18 16/30 .018 .035 .330
4P18T16NS 4 18 16/30 .018 .035 .335
5P18T16NS 5 18 16/30 .018 .035 .360
6P18T16NS 6 18 16/30 .018 .035 .440
9P18T16NS 9 18 16/30 .018 .040 .545
Audio & Communications
[email protected] 800-238-7514
16
One Twisted Pair Shielded NEC® Type CM
Twisted Pair, One Pair Shielded, One Pair Unshielded NEC® Type CM
Applications Special audio, communications and instrumentation uses requiring shielded groups to isolate circuits.
Applications Public address systems, unbalanced intercom systems, interconnecting cables, remote control circuits, low-voltage relay controls where RF shielding is required.
See referenced pages in the Hardware & Supplies section:
Installation HardwareAcme 25A Staple Gun - I-3
Suggested Prep Tools721 Multi-Wire Stripper/Cutter - I-9
•
•
See referenced pages in the Hardware & Supplies section:
Installation HardwareAcme 25A or 75A Staple Gun - I-3
Suggested Prep Tool721 Multi-Wire Stripper/Cutter - I-9
•
•
Conductors Stranded, tinned copper
Insulation Color-coded polypropylene (2P22) or PE
Shield Mylar/aluminum foil tape with copper drain wire on one pair only
Jacket Gray PVC
Specifi cations
Part No.
No. of Cond. AWG
Cond. Stranding
Nom. Insulation Thickness (in)
Nom. Jacket Thickness (in)
Nominal O.D. (in)
2P22T7PIP0 42-22 shielded
7/30 .010 .02 .1782-22 unshielded
2P20T10PIP0 42-20 shielded
10/30 .015 .025 .2152-20 unshielded
3C20T10PIC0 32-20 shielded
10/30 .015 .028 .2101-20 unshielded
Conductors Stranded, tinned copper
Insulation PE
Shield Overall Mylar/aluminum foil tape with stranded, tinned copper drain wire
Jacket Gray PVC
Specifi cations
Part No.
No. of Pairs AWG
Cond. Stranding
Nom. Insulation Thickness (in)
Nom. Jacket Thickness (in)
Nominal O.D. (in)
1P22T7PS 1 22 7/30 .015 .025 .170
1P20T10PS 1 20 10/30 .015 .025 .185
1P18T16PS 1 18 16/30 .018 .030 .235
1P16T19PS 1 16 19/29 .030 .030 .310
1P14T19PS 1 14 19/27 .032 .035 .350
1P12T19PS 1 12 19/25 .034 .040 .410
Some air plenum designs also available.
Audio & Communications
[email protected] 800-238-7514
17
Applications Special audio, communications and instrumentation uses requiring shielded groups to isolate circuits.
Twisted Pair Each Pair Individually Shielded NEC® Type CM
See referenced pages in the Hardware & Supplies section:
Installation HardwareAcme 25A, 37A or 75A Staple Gun - I-3
Suggested Prep Tool721 Multi-Wire Stripper/Cutter - I-9
•
•
Conductors Stranded, tinned copper
Insulation PE
Shield Mylar/aluminum foil tape with stranded, tinned copper drain wire on one pair only
Jacket Gray PVC
Specifi cations
Part No.
No. of Pairs AWG
Cond. Stranding
Nom. Insulation Thickness (in)
Nom. Jacket Thickness (in)
Nominal O.D. (in)
2P22T7EPS 2 22 7/30 .010 .045 .190
3P22T7EPS 3 22 7/30 .010 .045 .295
6P22T7EPS 6 22 7/30 .010 .045 .375
9P22T7EPS 9 22 7/30 .010 .045 .430
11P22T7EPS 11 22 7/30 .010 .045 .465
12P22T7EPS 12 22 7/30 .010 .045 .480
15P22T7EPS 15 22 7/30 .010 .060 .565
17P22T7EPS 17 22 7/30 .010 .060 .590
19P22T7EPS 19 22 7/30 .010 .060 .620
27P22T7EPS 27 22 7/30 .010 .060 .700
3P20T10EPS 3 20 10/30 .013 .045 .340
6P20T10EPS 6 20 10/30 .013 .045 .435
9P20T10EPS 9 20 10/30 .013 .060 .500
12P20T10EPS 12 20 10/30 .013 .060 .595
15P20T10EPS 15 20 10/30 .013 .060 .655
3P18T16EPS 3 18 16/30 .016 .045 .400
6P18T16EPS 6 18 16/30 .016 .045 .495
9P18T16EPS 9 18 16/30 .016 .060 .590
12P18T16EPS 12 18 16/30 .016 .070 .705
15P18T16EPS 15 18 16/30 .016 .070 .78
Some air plenum designs also available.
Audio & Communications
[email protected] 800-238-7514
18
Twisted Pair, Direct Earth Burial Each Pair Individually Shielded
For 300V Rated Communications Cable, see pages 10-14 in the IMSA Spec section.
For Air Core Outside Telephone Cable (ideal for low-voltage applications where many conductors/pairs are needed and flexibility is not a critical factor), see pages 2 and 4 in the Outside Telephone section.
Applications Suitable for direct earth burial, outdoor uses.
See referenced pages in the Hardware & Supplies section:
Installation HardwareAcme 75A Staple Gun - I-3
Suggested Prep Tool721 Multi-Wire Stripper/Cutter - I-9
•
•
Conductors Stranded, tinned copper
Insulation PE
Shield Mylar/aluminum foil tape with a stranded, tinned copper drain wire on each pair
Jacket Black PE
Specifi cations
Part No.
No. of Pairs AWG
Cond. Stranding
Nom. Insulation Thickness (in)
Nom. Jacket Thickness (in)
Nominal O.D. (in)
3P20T10EPS1 3 20 10/30 .013 .040 .340
6P20T10EPS1 6 20 10/30 .013 .045 .480
1P16T19I502 1 16 19/30 .030 .030 .285
1P14T19I502 1 14 19/27 .030 .030 .340
1P12T19I502 1 12 19/25 .030 .030 .380
Audio & Communications
[email protected] 800-238-7514
19
Plenum Electronic Cable, Unshielded NEC® 725, Type CMP and/or CL2P UL Classified as to fire and smoke only
Applications Security, audio, intercom, power limited control circuits; for installation through air plenums without metal conduit.
See referenced pages in the Hardware & Supplies section:
Installation HardwareAcme 25A or 75A Staple Gun - I-3
Suggested Prep Tool721 Multi-Wire Stripper/Cutter - I-9
•
•
Part No.No. of Cond. AWG
Cond. Description
Nominal O.D. (in)
Weight (lbs/M-ft)
1P22B7NSP 1 pair 22 stranded bare .115 16
4C22B7NSP 4 22 stranded bare .140 25
6C22B7NSP 6 22 stranded bare .160 28
8C22B7NSP 8 22 stranded bare .180 32
10C22B7NSP 10 22 stranded bare .192 40
12C22B7NSP 12 22 stranded bare .220 46
1P18B1NSP 1 pair 18 solid bare .132 22
1P18B7NSP 1 pair 18 stranded bare .145 24
3C18B1NSP 3 18 solid bare .140 28
3C18B7NSP 3 18 stranded bare .155 30
4C18B1NSP 4 18 solid bare .155 35
4C18B7NSP 4 18 stranded bare .175 37
5C18B7NSP 5 18 stranded bare .195 45
6C18B1NSP 6 18 solid bare .215 52
6C18B7NSP 6 18 stranded bare .215 52
8C18B1NSP 8 18 solid bare .230 66
8C18B7NSP 8 18 stranded bare .230 68
10C18B1NSP 10 18 solid bare .280 82
10C18B7NSP 10 18 stranded bare .280 82
1P16B7NSP 1 pair 16 stranded bare .163 25
3C16B19NSP 3 16 stranded bare .185 35
4C16B19NSP 4 16 stranded bare .205 46
1P14B19NSP 1 pair 14 stranded bare .196 40
3C14B19NSP 3 14 stranded bare .240 54
4C14B19NSP 4 14 stranded bare .265 70
1P12B7NSP 1 pair 12 stranded bare .267 60
4C12B7NSP 4 12 stranded bare .410 110
Conductors Solid bare copper, stranded bare copper
Insulation Low smoke-producing, low flame-spread compounds
Jacket Low smoke-producing, low flame-spread approved compounds
Specifi cations
Audio & Communications
[email protected] 800-238-7514
20
Plenum Electronic Cable, Shielded NEC® 725, Type CMP and/or CL2P UL Classified as to fire and smoke only
Applications Security, audio, intercom, power limited control circuits; for installation through air plenums without metal conduit.
See referenced pages in the Hardware & Supplies section:
Installation HardwareAcme 25A or 75A Staple Gun - I-3
Suggested Prep Tool721 Multi-Wire Stripper/Cutter - I-9
•
•
Conductors Solid bare copper or stranded bare copper
Insulation Low smoke-producing, low flame-spread compounds
Shield Overall Mylar/aluminum foil tape with a stranded, tinned copper drain wire
Jacket Low smoke-producing, low flame-spread approved compounds
Specifi cations
Part No.No. of Cond. AWG
Cond. Description
Nominal O.D. (in)
Weight (lbs/M-ft)
1P22B70SP 1 pair 22 stranded bare .110 18
4C22B70SP 4 22 stranded bare .125 22
6C22B70SP 6 22 stranded bare .182 28
8C22B70SP 8 22 stranded bare .199 36
10C22B70SP 10 22 stranded bare .224 42
12C22B70SP 12 22 stranded bare .236 50
1P18B10SP 1 pair 18 solid bare .110 18
1P18B70SP 1 pair 18 stranded bare .150 26
3C18B70SP 3 18 stranded bare .160 34
4C18B70SP 4 18 stranded bare .180 40
6C18B70SP 6 18 stranded bare .220 50
8C18B70SP 8 18 stranded bare .240 70
1P16B70SP 1 pair 16 stranded bare .180 30
4C16B190SP 4 16 stranded bare .215 50
2C14B190SP 2 14 stranded bare .225 46
4C14B190SP 4 14 stranded bare .270 76
Each Pair Shielded:
2P18T7EPSP 2 pair 18 stranded tinned .192 48
Other sizes available upon request.
Audio & Communications
[email protected] 800-238-7514
21
Category 5E CMR/CMX Indoor/Outdoor
Indoor/Outdoor Station Wire NEC® and UL specifications, UL Listed Type CMX
Part No. 4P24B1CMX5E
Application Demarcation wire.
See referenced pages in the Hardware & Supplies section:
Installation HardwareAcme 25A Staple Gun - I-3
Suggested Prep Tool721 Multi-Wire Stripper/Cutter - I-9
•
•
Conductors Solid, soft-drawn annealed bare copper
Insulation High density PE, color-coded
Jacket Flexible gray or beige PVC
Specifi cations
Part No.No. of Cond. AWG
Insulation Thick. (in)
Nominal O.D. (in)
Weight (lbs/M-ft)
4C24B1CMX 4 24 .01 .132 15
2C22B1CMX 2 22 .01 .124 12
3C22B1CMX 3 22 .01 .135 15
4C22B1CMX 4 22 .01 .150 18
5C22B1CMX 5 22 .01 .185 22
Color Ordering ChartPair Colors
1 Blue/White
2 Orange/White
3 Green/White
4 Brown/White
Conductors 24 AWG solid, annealed bare copper
Insulation Polyolefin
Jacket Tough, flame-retardant, weather- and abrasion-resistant PVC
Specifi cations
Part No.No. of Pairs AWG
Insulation Thick. (in)
Nominal O.D. (in)
Weight (lbs/M-ft)
2P22B1CMX 2 22 .01 .185 18
3P22B1CMX 3 22 .01 .200 26
4P22B1CMX 4 22 .01 .235 34
Color Ordering ChartNo. of Cond. Colors
2 Red/Green
3 Red/Green/Yellow
4 Red/Green/Yellow/Black
5 Red/Green/Yellow/Black/White
Audio & Communications
[email protected] 800-238-7514
22
Plenum Station Wire NEC® and UL® specifications, UL Listed Type CMP
Cross-Connect Wire, PW
Application Demarcation wire used inside the house.
Application Cross-connect termination boxes.
See referenced pages in the Hardware & Supplies section:
Installation HardwareAcme 25A Staple Gun - I-3
Suggested Prep Tools100 Adjustable Wire Stripper/Cutter - I-9
•
•
See referenced pages in the Hardware & Supplies section:
Installation HardwareAcme 25A Staple Gun - I-3
Suggested Prep Tools721 Multi-Wire Stripper/Cutter - I-9
•
•
Conductors Solid, soft-drawn annealed bare copper
Insulation Low smoke-producing, low flame-spread compounds with cross-reference
Configuration Twisted pairs
Jacket Low smoke-producing, low flame-spread approved compounds
Specifi cations
Part No.No. of Pairs AWG
Nominal O.D. (in)
Weight (lbs/M-ft)
1P24B1PW 1 24 0.08 5
2P24B1PW 2 24 0.13 8
3P24B1PW 3 24 0.16 12
Conductors Solid, soft-drawn annealed bare copper
Configuration Non-jacketed twisted pairs
Jacket Solid, semi-rigid PVC with cross-reference band-marked color code
Specifi cations
Part No.No. of Cond. AWG
Insulation Thick. (in)
Nominal O.D. (in)
Weight (lbs/M-ft)
4C24B1CMP 4 24 .1 .132 12
2C22B1CMP 2 22 .1 .124 12
4C22B1CMP 4 22 .1 .145 20
Color Ordering ChartNo. of Cond. Colors
2 Red/Green
4 Red/Green/Yellow/Black
Voice, Video Data & Broadband
[email protected] 800-238-7514
23
Specifications Connectorized cables save installation time by minimizing on-the-job terminating and cable splicing. Pre-tested, factory-assembled connectorized cables also minimize installation terminating and splicing mistakes.
Connectorized Inside Telephone Type CM
Type designations:
Type PX: Plug on one end
Type CX: Connector on one end
Type PC: Plug on one end, connector on other end
Type PP: Plug on both ends
Type CC: Connector on both ends
•••••
6-pair
12-pair
25-pair
50-pair
••••
75-pair
100-pair
200-pair
•••
Standard connectorized cable sizes
5'
10'
15'
20'
25'
•••••
30'
50'
75'
100'
125'
•••••
150'
175'
200'
250'
••••
Standard lengths Custom made to your requirements
Configuration 25-pair plugs (P = male) and/or 25-pair connectors (C = female) on one or both ends. On 50-pair and larger cables, the cable ends are divided into 25-pair sub-units, to which the 25-pair plugs/connectors are applied.
Voice, Video Data & Broadband
[email protected] 800-238-7514