4
bizhub PRO 920 13. MALFUNCTION CODE 479 Field Service Ver3.0 May.2006 Main body Fan abnor- mality The main body stops immedi- ately to turn OFF the main relay (RL1). SC42-16 The rotation of the polygon cool- ing fan (FM9) is checked and the 24V power source is also checked. An abnormal condition occurs with the FM9 EM signal a speci- fied period of time after FM9 turns ON. This abnormal condition recurs even a specified period of time after FM9 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected. DC power supply /2 (DCPS2) AC drive board (ACDB) Polygon cooling fan (FM9) Wiring harness broken Loose connection SC42-17 The blowout of ICP for the poly- gon cooling fan (FM9) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM9 EM signal a speci- fied period of time after FM9 turns ON. This abnormal condition recurs even a specified period of time after FM9 is turned OFF and then turned ON, and an error detection signal (blowout of ICP) is detected. SC42-18 The rotation of the polygon cool- ing fan (FM9) is checked. An abnormal condition occurs with the FM9 EM signal a speci- fied period of time after FM9 turns ON. This abnormal condition recurs even a specified period of time after FM9 is turned OFF and then turned ON, and an error detection signal (24V cut off/ blowout of ICP) is not detected. Classification Code Causes Resulting operation Estimated abnormal parts

Upload: hugo-luis-escalante

Post on 30-Oct-2014

249 views

Category:

Documents


13 download

TRANSCRIPT

Page 1: Code SC42-16_ SC42-17_ SC42-18 Bizhub PRO 920

bizh

ub P

RO

920

13. MALFUNCTION CODE

479

Field Service Ver3.0 May.2006

Mai

n bo

dy Fan

abnor-

mality

The main body

stops immedi-

ately to turn OFF

the main relay

(RL1).

SC42-16 The rotation of the polygon cool-

ing fan (FM9) is checked and the

24V power source is also

checked.

An abnormal condition occurs

with the FM9 EM signal a speci-

�ed period of time after FM9 turns

ON. This abnormal condition

recurs even a speci�ed period of

time after FM9 is turned OFF and

then turned ON, and an error

detection signal (24V cut o�) is

detected.

DC power supply /2

(DCPS2)

AC drive board (ACDB)

Polygon cooling fan (FM9)

Wiring harness broken

Loose connection

SC42-17 The blowout of ICP for the poly-

gon cooling fan (FM9) in the AC

drive board (ACDB) is checked.

An abnormal condition occurs

with the FM9 EM signal a speci-

�ed period of time after FM9 turns

ON. This abnormal condition

recurs even a speci�ed period of

time after FM9 is turned OFF and

then turned ON, and an error

detection signal (blowout of ICP)

is detected.

SC42-18 The rotation of the polygon cool-

ing fan (FM9) is checked.

An abnormal condition occurs

with the FM9 EM signal a speci-

�ed period of time after FM9 turns

ON. This abnormal condition

recurs even a speci�ed period of

time after FM9 is turned OFF and

then turned ON, and an error

detection signal (24V cut o�/

blowout of ICP) is not detected.

Classi�cation Code Causes Resulting

operation

Estimated abnormal parts

Page 2: Code SC42-16_ SC42-17_ SC42-18 Bizhub PRO 920

14. PARTS LAYOUT DRAWING

528

Field Service Ver2.0 Aug.2005

bizh

ub P

RO

920

D. Main body left side

[1] DC power supply /2 (DCPS2)

[1]

57gaf5c031na

Page 3: Code SC42-16_ SC42-17_ SC42-18 Bizhub PRO 920

14. PARTS LAYOUT DRAWING

526

Field Service Ver2.0 Aug.2005bi

zhub

PR

O 9

2014.1.3 Boards and others

A. Main body rear side

)BDCA( draob evird CA]3[

57gaf5c028na

[3]

Page 4: Code SC42-16_ SC42-17_ SC42-18 Bizhub PRO 920

14. PARTS LAYOUT DRAWING

518

Field Service Ver2.0 Aug.2005

bizh

ub P

RO

920

D. Write section

)9MF( naf gnilooc nogyloP]2[

57gaf5c017na

[2]