OPEN FRONT BOOTH

OVERVIEWThe Open Front Booth is designed for both batch type and conveyorized production systems. Air flow is drawn in through the

open front, across the work area and exhausted through a filter bank in the back of the booth. The dry arrestor filters trap the

airborne overspray particles before the filtered air is discharged through the exhaust system and into the atmosphere. The booths

are available in a wide range of designs to meet practically any production requirement. Conveyor pass-through openings can be

as much as 25% of the booth open front area, without requiring additional exhaust fan capacity. Specially engineered enclosures

may be designed to meet your requirements. Air replacement units and intake chambers can be added as well as reduced air flows

for automatic spray operations.

LIGHTING FEATURESLighted booths provide a bright, full booth illumination from four-tube, 48" long, 32-watt, fluorescent light fixtures. All fixtures are UL

listed and approved for their intended use and placement. The light tubes are furnished with Class I Division II sealed and gasketed

fixtures.

electric components can

be purchased separately

control panel is added

A tubeaxial exhaust fan designed specifically for use in

paint spray booths powers the airflow, through the booth

and exhaust stack. All exhaust fans are of non-sparking

construction.The motor drive and bearings are sealed

from the air stream of the exhaust. Motors are provided

with each unit.

prime-quality steel

are precision punched for easy

nut and bolt assembly

Industrial Auto Wood

Page 3: Col-Met 2013 Sales Literature

Model Interior Dimensions Exterior Dimensions Qty. Qty. Fan Fan SCFM @ ShippingNumber Width Height Length Width Height Length Lights Filters Diameter HP 1/2” SP Weight IB-04-07-05 4’-0" 7’-0" 5’-0" 4’-4” 7’-2” 7’-2” 0 8 18” .75HP 3,500 675IB-06-07-05 6’-0" 7'-0" 5’-0" 6’-4” 7’-2” 7’-8” 1 12 24” 1HP 5,250 940IB-08-07-05 8’-0" 7'-0" 5’-0" 8’-4” 7’-2” 7’-8” 1 16 24” 2HP 7,150 1,240IB-10-07-05 10’-0" 7'-0" 5’-0" 10’-4” 7’-2” 8’-2” 2 20 30” 2HP 8,750 1,630IB-12-07-07 12’-0" 7'-0" 7’-0" 12’-4” 7’-2” 10’-2” 2 24 30” 3HP 10,500 1,870IB-14-07-07 14’-0" 7'-0" 7’-0" 15’-0” 7’-6” 10’-8” 2 32 30” 3HP 12,250 2,450IB-16-07-07 16’-0" 7'-0" 7’-0" 17’-0” 7’-6” 10’-8” 2 36 30” 5HP 14,000 2,650IB-18-07-07 18’-0" 7'-0" 7’-0" 19’-0” 7’-6” 11’-8” 3 40 36” 5HP 15,750 3,000 IB-20-07-07 20’-0" 7’-0" 7’-0" 21’-0” 7’-6” 11’-8” 4 44 36” 5HP 17,500 3,540

IB-04-08-05 4’-0" 8’-0" 5’-0" 4’-4” 8’-2” 7’-2” 0 8 18” .75HP 4,000 703IB-06-08-05 6’-0" 8’-0" 5’-0" 6’-4” 8’-2” 7’-8” 1 12 24” 1.5HP 6,000 1,020IB-08-08-05 8’-0" 8’-0" 5’-0" 8’-4” 8’-2” 7’-8” 1 16 24” 2HP 8,000 1,490IB-10-08-05 10’-0" 8’-0" 5’-0" 10’-4” 8’-2” 8’-2” 2 20 30” 3HP 10,000 1,780IB-12-08-07 12'-0" 8’-0" 7’-0" 12’-4” 8’-2” 10’-2” 2 24 30” 3HP 12,000 2,270IB-14-08-07 14’-0" 8’-0" 7’-0" 15’-0” 8’-6” 10’-8” 2 32 30” 5HP 14,000 2,600IB-16-08-07 16’-0" 8’-0" 7’-0" 17’-0” 8’-6” 11’-8” 2 36 36” 5HP 16,000 2,810 IB-18-08-07 18’-0" 8’-0" 7’-0" 19’-0” 8’-6” 11’-8” 3 40 36” 5HP 18,000 3,150IB-20-08-07 20’-0" 8’-0" 7’-0" 21’-0” 8’-6” 11’-8” 4 44 42” 5HP 20,000 3,690

IB-04-10-05 4’-0" 10’-0" 5’-0" 4’-4” 10’-2” 7’-2” 0 10 18” 1.5HP 5,000 1,100IB-06-10-05 6’-0" 10’-0" 5’-0" 6’-4” 10’-2” 7’-8” 1 15 24” 2HP 7,500 1,650IB-08-10-05 8’-0" 10’-0" 5’-0" 8’-4” 10’-2” 8’-2” 1 20 30” 2HP 10,000 1,900IB-10-10-05 10’-0" 10’-0" 5’-0" 10’-4” 10’-2” 8’-2” 2 25 30” 3HP 12,500 2,350IB-12-10-07 12’-0" 10’-0" 7’-0" 12’-4” 10’-2” 10’-2” 2 30 30” 5HP 15,000 2,500IB-14-10-07 4’-0" 10’-0" 7’-0" 15’-0” 10’-6” 11’-8” 2 40 36” 5HP 17,500 3,000IB-16-10-07 16’-0" 10’-0" 7’-0" 17’-0” 10’-6” 11’-8” 2 45 42” 5HP 20,000 3,400IB-18-10-07 18’-0" 10’-0" 7’-0" 19’-0” 10’-6” 11’-8” 3 50 42” 5HP 22,500 4,000IB-20-10-07 20’-0" 10’-0" 7’-0" 21’-0” 10’-6” 11’-8” 4 55 42” 7.5HP 25,000 4,400

IB-04-12-05 4’-0" 12’-0" 5’-0" 4’-4” 12’-2” 7’-8” 0 12 24” 1.5HP 6,000 975IB-06-12-05 6’-0" 12’-0" 5’-0" 6’-4” 12’-2” 7’-8” 1 18 24” 3HP 9,000 1,500IB-08-12-05 8’-0" 12’-0" 5’-0" 8’-4” 12’-2” 8’-2” 1 24 30” 3HP 12,000 1,700IB-10-12-05 10’-0" 12’-0" 5’-0" 10’-4” 12’-2” 8’-2” 2 30 30” 5HP 15,000 2,200IB-12-12-07 12’-0" 12’-0" 7’-0" 12’-4” 12’-2” 11’-2” 2 36 36” 5HP 18,000 2,500IB-14-12-07 14’-0" 12’-0" 7’-0" 15’-0” 12’-6” 11’-8” 2 48 42” 5HP 21,000 3,200IB-16-12-07 16’-0" 12’-0" 7’-0" 17’-0” 12’-6” 11’-8” 2 54 42” 7.5HP 24,000 3,500IB-18-12-07 18’-0" 12’-0" 7’-0" 19’-0” 12’-6” 11’-8” 3 60 42” 7.5HP 27,000 4,100IB-20-12-07 20’-0" 12’-0" 7’-0" 21’-0” 12’-6” 11’-8” 4 66 42” 10HP 30,000 4,700

OPEN FRONT BOOTH

Ref. Key A B C D

Industrial Auto Wood

Col-Met Spray Booths - Rockwall, TX // e-mail: [email protected] - Toll-free: 888.452.6684 // www.colmetsb.com

Page 4: Col-Met 2013 Sales Literature

OPEN FRONT BENCH BOOTH

OVERVIEWThe Open Front Bench Booth is designed for both batch type and conveyorized production systems. Air flow is drawn in through the open front, across the painter and parts being coated and exhausted through a filter bank in the back of the booth. The dry arrestor filters trap the airborne overspray particles before the filtered air is discharged through the exhaust system and into the atmosphere. The booths are available in a wide range of designs to meet practically any production requirement. Conveyor pass through openings can be as much as 25% of the booth open front area, without requiring additional exhaust fan capacity. Specially engineered enclosures may be designed to meet your requirements. Air replacement units and intake chambers can be added as well as reduced air flows for automatic spray operations.LIGHTING FEATURESLighted booths provide a bright, full booth illumination from four-tube, 48" long, 32-watt, fluorescent light fixtures. Each is Class I, Division II, sealed and gasketed construction. All fixtures are UL listed and approved for their intended use and placement. The light tubes are furnished with Class I Division II sealed and gasketed fixtures.

electric components can be purchased separately control panel is added

EXHAUST SYSTEM FEATURESA tubeaxial exhaust fan designed specifically for use in paint spray booths powers the airflow through the booth and exhaust stack. All exhaust fans are of non-sparking construction. The motor drive and bearings are sealed from the air stream of the exhaust. Motors are provided with each unit.

prime-quality steel are precision punched for easy nut and bolt assembly

Industrial Auto Wood

Page 5: Col-Met 2013 Sales Literature

Ref. Key A B C D

* Optional 36", two-tube light fixture available.

Model Interior Dimensions Exterior Dimensions Qty. Qty. Fan Fan SCFM @ ShippingNumber Width Height Length Width Height Length Lights Filters Diameter HP 1/2" SP

IBB-04-07-02 4'-0" 4'-0" 2'-0" 4'-4" 7'-2" 4'-2" 0* 4 18" .75HP 2,000 675IBB-05-07-03 5'-0" 4'-0" 3'-0" 5'-4" 7'-2" 5'-2" 1 4 18" .75HP 2,500 940IBB-06-07-03 6'-0" 4'-0" 3'-0" 6'-4" 7'-2" 5'-2" 1 6 18" .75HP 3,000 1,240IBB-08-07-03 8'-0" 4'-0" 3'-0" 8'-4" 7'-2" 5'-2" 1 8 18" 1 HP 4,000 1,630IBB-10-07-03 10'-0" 4'-0" 3'-0" 10'-4' 7'-2" 5'-2" 2 10 18" 1.5 HP 5,000 1,870IBB-12-07-03 12'-0" 4'-0" 3'-0" 12'-4" 7'-2" 5'-8" 2 12 24" 1.5 HP 6,000 2,450

OPEN FRONT BENCH BOOTH

Industrial Auto Wood

Page 6: Col-Met 2013 Sales Literature

ENCLOSED INDUSTRIAL BOOTH

Industrial Auto Wood

OVERVIEWAir flows in through the filtered double entry doors in the front of the booth, passes through the booth’s working area, and into the filtered exhaust chamber located in the rear of the booth. This filtered exhaust air is drawn through the exhaust plenum anddischarged upward into the atmosphere through the exhaust stack. Our Industrial Enclosure booths make efficient use of your valuable floor space and are available in four heights to accommodate your needs.LIGHTING FEATURESBright, full-booth illumination is provided by four 48 , four-tube, 32-watt fluorescent light fixtures placed in the ceiling panels and side walls. Each is sealed behind clear tempered safety glass. All fixtures are UL listed and approved for their intended use and placement.

electric components can be purchased separately control panel is added

prime-quality steel are precision punched for easy nut and bolt assembly

doors are pre-hung in a heavy gauge galvanized steel frame for easy installation.on slotted hinges to facilitate

OR

CROSSDRAFT

MODIFIED DOWNDRAFT

Page 7: Col-Met 2013 Sales Literature

Col-Met Spray Booths - Rockwall, TX // e-mail: [email protected] - Toll-free: 888.452.6684 // www.colmetsb.com

Interior Dimensions Exterior Dimensions Nominal Door Opening Qty. Filters Fan Fan SCFM @ Width Height Length Width Height Length Width Height Qty Type Lights Exhaust Diameter HP 1/2” SP 10’-0" 7’-0" 5’-0" 10’-4” 7’-2” 7’-10” 9'-4" 6'-10.5" 1 Filtered 2 20 24” 2HP 7,000 12’-0" 7’-0" 7’-0" 12’-4” 7’-2” 9’-10” 11'-4" 6'-10.5" 1 Filtered 2 24 24” 3HP 8,400 14’-0" 7’-0" 7’-0" 15’-0” 7’-6” 10’-8” 13'-4" 6'-10.5" 1 Filtered 2 32 30” 3HP 9,800 16’-0" 7’-0" 7’-0" 17’-0” 7’-6” 10’-8” 13'-4" 6'-10.5" 1 Filtered 2 36 30” 3HP 11,200 18’-0" 7’-0" 7’-0" 19’-0” 7’-6” 10’-8” 13'-4" 6'-10.5" 1 Filtered 3 40 30” 3HP 12,600 20’-0" 7’-0" 7’-0" 21’-0” 7’-6” 10’-8” 13'-4" 6'-10.5" 1 Filtered 4 44 30” 5HP 14,000

10’-0" 8’-0" 5’-0" 10’-4” 8’-2” 7’-10” 9'-4" 7'-10.5" 1 Filtered 2 20 24” 3HP 8,000 12'-0" 8’-0" 7’-0" 12’-4” 8’-2” 10’-4” 11'-4" 7'-10.5" 1 Filtered 2 24 30” 3HP 9,600 14’-0" 8’-0" 7’-0" 15’-0” 8’-6” 10’-8” 13'-4" 7'-10.5" 1 Filtered 2 32 30” 3HP 11,200 16’-0" 8’-0" 7’-0" 17’-0” 8’-6” 10’-8” 13'-4" 7'-10.5" 1 Filtered 2 36 30” 5HP 12,800 18’-0" 8’-0" 7’-0" 19’-0” 8’-6” 10’-8” 13'-4" 7'-10.5" 1 Filtered 3 40 30” 5HP 14,400 20’-0" 8’-0" 7’-0" 21’-0” 8’-6” 11’-8” 13'-4" 7'-10.5" 1 Filtered 4 44 36” 5HP 16,000

10’-0" 10’-0" 5’-0" 10’-4” 10’-2” 8’-4” 9'-4" 9'-10.5" 1 Filtered 2 25 30” 3HP 10,000 12’-0" 10’-0" 7’-0" 12’-4” 10’-2” 10’-4” 11'-4" 9'-10.5" 1 Filtered 2 30 30” 3HP 12,000 14’-0" 10’-0" 7’-0" 15’-0” 10’-6” 10’-8” 13'-4" 9'-10.5" 1 Filtered 2 40 30” 5HP 14,000 16’-0" 10’-0" 7’-0" 17’-0” 10’-6” 11’-8” 13'-4" 9'-10.5" 1 Filtered 2 45 36” 5HP 16,000 18’-0" 10’-0" 7’-0" 19’-0” 10’-6” 11’-8” 13'-4" 9'-10.5" 1 Filtered 3 50 36” 5HP 18,000 20’-0" 10’-0" 7’-0" 21’-0” 10’-6” 11’-8” 13'-4" 9'-10.5" 1 Filtered 4 55 42” 5HP 20,000

10’-0" 12’-0" 5’-0" 10’-4” 12’-2” 8’-4” 9'-4" 11'-10.5" 1 Filtered 2 30 30” 3HP 12,000 12’-0" 12’-0" 7’-0" 12’-4” 12’-2” 10’-4” 11'-4" 11'-10.5" 1 Filtered 2 36 30” 5HP 14,400 14’-0" 12’-0" 7’-0" 15’-0” 12’-6” 11’-8” 13'-4" 11'-10.5" 1 Filtered 2 48 36” 5HP 16,800 16’-0" 12’-0" 7’-0" 17’-0” 12’-6” 11’-8” 13'-4" 11'-10.5" 1 Filtered 2 54 42” 5HP 19,200 18’-0" 12’-0" 7’-0" 19’-0” 12’-6” 11’-8” 13'-4" 11'-10.5" 1 Filtered 3 60 42” 5HP 21,600 20’-0" 12’-0" 7’-0" 21’-0” 12’-6” 11’-8” 13'-4" 11'-10.5" 1 Filtered 4 66 42” 7.5HP 24,000

ENCLOSED INDUSTRIAL BOOTH

Industrial Auto Wood

Model Number EIB-10-07-05-00 EIB-12-07-07-00 EIB-14-07-07-00 EIB-16-07-07-00 EIB-18-07-07-00 EIB-20-07-07-00

EIB-10-08-05-00 EIB-12-08-07-00 EIB-14-08-07-00 EIB-16-08-07-00 EIB-18-08-07-00 EIB-20-08-07-00

EIB-10-10-05-00 EIB-12-10-07-00 EIB-14-10-07-00 EIB-16-10-07-00 EIB-18-10-07-00 EIB-20-10-07-00

EIB-10-12-05-00 EIB-12-12-07-00 EIB-14-12-07-00 EIB-16-12-07-00 EIB-18-12-07-00 EIB-20-12-07-00 Reference Key A B C D E

Page 8: Col-Met 2013 Sales Literature

EZ EXHAUST CHAMBERS

The EZ Exhaust Chamber is designed for exhausting dust, harmful vapors and into the atmosphere. The chambers are available in a wide range of designs to meet practically any production requirement. Air replacement automatic spray operations.

for use in paint spray exhaust chambers, exhaust stack. All exhaust fans are of non-sparking construction. The motor drive and bearings are sealed from the air stream of the exhaust. Motors are provided with each unit.Optional explosion-proof motor upgrade is

Chambers are constructed from 18-gauge, prime quality, galvanized steel. Structural steel is used to add strength and rigidity to chambers supplied by others.

This exhaust bench provides a very practical method for removing other shop-related operations.

thereby reducing health hazards for shop personnel.

Industrial Auto Wood

Page 9: Col-Met 2013 Sales Literature

Model Exterior Dimensions Qty. Fan Fan SCFM @Number Width Height Length Filters Diameter HP 1/2" SPIBC-04-07 4'-4" 7'-2" 2'-2" 8 18" .75HP 3,500

IBC-06-07 6'-4" 7'-2" 2'-8" 12 24" 1HP 5,250

IBC-08-07 8'-4" 7'-2" 2'-8" 16 24" 2HP 7,000

IBC-10-07 10'-4" 7'-2" 3'-2" 20 30" 2HP 8,750

IBC-12-07 12'-4" 7'-2" 3'-2" 24 30" 3HP 10,500

IBC-14-07 14'-4" 7'-2" 3'-6" 32 30" 3HP 12,250

IBC-16-07 16'-4" 7'-2" 3'-6" 36 30" 5HP 14,000

IBC-18-07 18'-4" 7'-2" 4'-6" 40 36" 5HP 15,750

IBC-20-07 20'-4" 7'-2" 4'-6" 44 36" 5HP 17,500

IBC-04-08 4'-4" 8'-2" 2'-2" 8 18" 1HP 4,000

IBC-06-08 6'-4" 8'-2" 2'-8" 12 24" 1.5HP 6,000

IBC-08-08 8'-4" 8'-2" 2'-8" 16 24" 3HP 8,000

IBC-10-08 10'-4" 8'-2" 3'-2" 20 30" 3HP 10,000

IBC-12-08 12'-4" 8'-2" 3'-2" 24 30" 3HP 12,000

IBC-14-08 14'-4" 8'-2" 3'-6" 32 30" 5HP 14,000

IBC-16-08 16'-4" 8'-2" 4'-6" 36 36" 5HP 16,000

IBC-18-08 18'-4" 8'-2" 4'-6" 40 36" 5HP 18,000

IBC-20-08 20'-4" 8'-2" 4'-6" 44 42" 5HP 20,000

IBC-04-10 4'-4" 10'-2" 2'-2" 10 18" 1.5HP 5,000

IBC-06-10 6'-4" 10'-2" 2'-8" 15 24" 2HP 7,500

IBC-08-10 8'-4" 10'-2" 3'-2" 20 30" 3HP 10,000

IBC-10-10 10'-4" 10'-2" 3'-2" 25 30" 3HP 12,500

IBC-12-10 12'-4" 10'-2" 3'-2" 30 30" 5HP 15,000

IBC-14-10 14'-4" 10'-2" 4'-6" 40 36" 5HP 17,500

IBC-16-10 16'-4" 10'-2" 4'-6" 45 42" 5HP 20,000

IBC-18-10 18'-4" 10'-2" 4'-6" 50 42" 5HP 22,500

IBC-20-10 20'-4" 10'-2" 4'-6" 55 42" 7.5HP 25,000

IBC-04-12 4'-4" 12'-2" 2'-8" 12 24" 1.5HP 6,000

IBC-06-12 6'-4" 12'-2" 2'-8" 18 24" 3HP 9,000

IBC-08-12 8'-4" 12'-2" 3'-2" 24 30" 3HP 12,000

IBC-10-12 10'-4" 12'-2" 3'-2" 30 30" 5HP 15,000

IBC-12-12 12'-4" 12'-2" 4'-2" 36 36" 5HP 18,000

IBC-14-12 14'-4" 12'-2" 4'-6" 48 42" 5HP 21,000

IBC-16-12 16'-4" 12'-2" 4'-6" 54 42" 7.5HP 24,000

IBC-18-12 18'-4" 12'-2" 4'-6" 60 42" 7.5HP 27,000

IBC-20-12 20'-4" 12'-2" 4'-6" 66 42" 10HP 30,000

Reference Key A B C

Model Exterior Dimensions CFM @ Fan Spec Filters ManometerNumber Width Height Length 1/2" SP Dia. HP Exhaust EB-12 12'-0" 3'-2" 2'-4" 5,000 18" 1.5 7 YES

EB-15 15'-0" 3'-2" 2'-4" 5,000 18" 1.5 8 YES

PLAN VIEW END VIEW SIDE ELEVATION

EZ EXHAUST CHAMBERS

Industrial Auto Wood

Page 10: Col-Met 2013 Sales Literature

EZ CLASSIC CROSSDRAFT

OVERVIEW

LIGHTING FEATURES

added

Industrial Auto Wood

Page 11: Col-Met 2013 Sales Literature

EZ CLASSIC CROSSDRAFT

Interior Dimensions Exterior Dimensions Access Nominal Door Opening Lights Air Flow Fan Spec. Filters Width Height Length Width Height Length Doors Width Height Qty Type Open S&G SCFM Dia. HP Int. Exh.

14’-0” 9’-0” 26’-0” 14’-6.5” 10’-0" 26’-4” 1 9’-4” 8’-10.5” 1 Filtered 9 1 12,600 30” 3HP 20 16

14’-0” 9’-0” 28’-0” 14’-6.5” 10’-0" 28’-4” 1 9’-4” 8’-10.5” 1 Filtered 9 1 12,600 30” 3HP 20 16

14’-0” 9’-0” 30’-0” 14’-6.5” 10’-0" 30’-4” 1 9’-4” 8’-10.5” 1 Filtered 9 1 12,600 30” 3HP 20 16

ModelNumber

ECC-14-09-26-N-SB

ECC-14-09-28-N-SB

ECC-14-09-30-N-SB

Reference Key A B C D E F

Alternative Configurations: Reverse Flow (RF) Drive Through (DT)Alternative Options: Pressurized (P)Standard Length Sizing is Illustrated above

Actual Working Depth is 18 inches less than interior length.

Industrial Auto Wood

Page 12: Col-Met 2013 Sales Literature

EZ MODIFIED DOWNDRAFT

Industrial Auto

OVERVIEW

LIGHTING FEATURES

Wood

Page 13: Col-Met 2013 Sales Literature

Interior Dimensions Exterior Dimensions Access Nominal Door Opening Lights Air Flow Fan Spec. Filters Width Height Length Width Height Length Doors Width Height Qty Type Open S&G SCFM Dia. HP Int. Exh.

14’-0” 9’-0” 26’-0” 14’-6.5” 10’-0" 26’-4” 1 9’-4” 8’-10.5” 1 Solid 9 1 12,600 30” 3HP 15 16

14’-0” 9’-0” 28’-0” 14’-6.5” 10’-0" 28’-4” 1 9’-4” 8’-10.5” 1 Solid 9 1 12,600 30” 3HP 15 16

14’-0” 9’-0” 30’-0” 14’-6.5” 10’-0" 30’-4” 1 9’-4” 8’-10.5” 1 Solid 9 1 12,600 30” 3HP 15 16

EZ MODIFIED DOWNDRAFT

ModelNumber

EMD-14-09-26-N-SB

EMD-14-09-28-N-SB

EMD-14-09-30-N-SB

Reference Key A B C D E F

Alternative Configurations: Reverse Flow (RF) Drive Through (DT) Alternative Options: Pressurized (P) Pre-Filtered (PF)Standard Length Sizing is Illustrated above

Actual Working Depth is 18 inches less than interior length.

Industrial Auto Wood

Page 14: Col-Met 2013 Sales Literature

EZ SIDE DOWNDRAFT

OVERVIEWThe Col-Met EZ Side Downdraft Booth intakes fresh air from the cleaner upper levels of the shop through a filtered booth ceiling. The filtered air is drawn down and away from the product through exhaust filters at the floor level, along both sides. This provides efficient overspray control that reduces prep time and also provides a much healthier workplace environment without an expensive downdraft exhaust pit. This booth can also be purchased with a pre-filtered plenum or with a pressurized intake plenum, the booth can also be equipped with an air replacement unit and cure cycle to meet your requirements. This booth also available in either drive-through or solid back configurations.LIGHTING FEATURESBright, full booth illumination is provided by ten four-tube, 48", 32-watt, fluorescent light fixtures in the angled ceiling panels and side walls. Each is sealed behind clear, tempered safety glass. All fixtures are UL listed and approved for their intended use and placement.

prime-quality steel are precision punched for easy nut and bolt assemblyfans and motors

doors are pre-hung in a heavy gauge galvanized steel frame for easy installation.on slotted hinges to facilitate

electric components can be purchased separately when control panel is added

Industrial Auto Wood

Page 15: Col-Met 2013 Sales Literature

Model Interior Dimensions Exterior Dimension Access Nominal Door Opening Lights Air Flow Fan Spec. FiltersNumber Width Height Length Width Height Length Doors Width Height Qty Type Open S&G SCFM Dia. HP Int. Exh.

ESD-14-09-26-N-SB 14’-0” 9’-0” 26’-0” 16’-4” 10’ -0" 26’-4” 1 9’-4” 8’-10.5” 1 Solid 9 1 12,740 (2) 24” 2HP 32 20

EZ SIDE DOWNDRAFT

Reference Key A B C D E F

Alternative Configurations: Drive Through (DT)Alternative Options: Pressurized (P) Pre-Filtered (PF)Standard Length Sizing is Illustrated above

Industrial Auto Wood

Page 16: Col-Met 2013 Sales Literature

• EZ TO INSTALL

• EZ TO OPERATE

• EZ TO MAINTAIN

• EZ TO PRESSURIZE

EZ PIT DOWNDRAFT

OVERVIEWThe EZ Pit Downdraft Booth takes in fresh air from the cleaner upper levels of the shop, through a filtered booth ceiling. The filtered air is drawn down and away from the product through exhaust filters in the pit located in the floor. This provides efficientoverspray control that reduces prep time and also provides a much healthier workplace environment. An optional above ground basement exhaust plenum is available for installation without concrete work.This booth can be purchased with a pre-filtered plenum or with a pressurized intake plenum. It can also be equipped with an air replacement unit and cure cycle to meet your requirements. The EZ Pit Downdraft Booth is available in either drive-through or solid back configurations.LIGHTING FEATURESBright, full booth illumination is provided by ten four-tube, 48 , 32-watt fluorescent light fixtures in the angled ceiling panels and side walls. Each is sealed behind clear tempered safety glass. All fixtures are UL listed and approved for their intended use and placement.

prime-quality steel are precision punched for easy nut and bolt assemblyfans and motors

Windowed personnel access doors are pre-hung in a heavy gauge galvanized steel frame for easy installation.to facilitate installation on

electric components can be purchased separately when control panel is added

BOOTH SHOWN WITH OPTIONAL ABOVE GROUND BASEMENT

Industrial Auto Wood

Page 17: Col-Met 2013 Sales Literature

Interior Dimensions Exterior Dimensions Access Nominal Door Opening Illumination Air Flow Fan Spec. Filters Width Height Length Width Height Length Doors Width Height Qty Type S&G Open Total SCFM Dia. HP Int. Exh.

14'-0" 9'-0" 26'-0" 14'-10.5" 10'-0" 26'-4" 1 9'-4" 8'-10.5" 1 Solid 1 9 10 12,740 30" 3 HP 32 24

ModelNumber EPD-14-09-26-N-SB

EZ PIT DOWNDRAFT

Reference Key A B C D E F

Alternative Configurations: Drive Through (DT)Alternative Options: Pressurized (P) Pre-Filtered (PF)Standard Length Sizing is Illustrated above

Industrial Auto Wood

Page 18: Col-Met 2013 Sales Literature

EZ PAINT MIXING ROOM

OVERVIEWLIGHTING FEATURES

Page 19: Col-Met 2013 Sales Literature

Interior Dimensions Exterior Dimensions Access Lights Air Flow Fan Spec. Filters

Width Height Length Width Height Length Doors Open S&G SCFM Dia. HP Int. Exh.

8'-0" 8'-0" 8'-0" 8'-4" 8'-2" 10'-6" 1 with Window 1 0 1450 12" ¾ HP 4 2

8'-0" 8'-0" 10'-0" 8'-4" 8'-2" 12'-6" 1 with Window 1 1 1450 12" ¾ HP 4 2

8'-0" 8'-0" 12'-0" 8'-4" 8'-2" 14'-6" 1 with Window 1 1 1450 12" ¾ HP 4 2

8'-0" 8'-0" 15'-0" 8'-4" 8'-2" 17'-6" 1 with Window 2 1 1450 12" ¾ HP 4 2

10'-0" 8'-0" 15'-0" 10'-4" 8'-2" 17'-6" 1 with Window 2 1 1450 12" ¾ HP 4 2

PMR-08-08-08

PMR-08-08-10

PMR-08-08-12

PMR-08-08-15

PMR-10-08-15

Model

Number

EZ PAINT MIXING ROOM

Ref. Key A B C D

Page 20: Col-Met 2013 Sales Literature

CONSTRUCTION FEATURES AND QUALITY STANDARDS

EZ LIMITED FINISHING PREP STATION

OVERVIEW

LIGHTING FEATURES

BOOTH SHOWN WITH OPTIONAL CURTAINS

Industrial Auto Wood

Page 21: Col-Met 2013 Sales Literature

Interior Dimensions Exterior Dimensions Nominal Clear Entry Lights Air Flow Fan Spec. Filters

Width Height Length Width Height Length Width Height Open SCFM Dia. HP Int. Ext.

14’-0” 10’-0” 24’-0” 14’-4” 12’-2” 26’-6” 14’-0” 10’-0” 8 5,000 (2)18” 1.5 12 12EPS-14-10-24-P-SB

Model

Number

EZ LIMITED FINISHING PREP STATION

Reference Key A B C

Industrial Auto Wood

Page 22: Col-Met 2013 Sales Literature

500° POWDER CURE BATCH OVEN

Technical Data

Construction

Industrial Powder

COL-MET STANDARD CONTROLS COL-MET SMART TOUCH CONTROLS

Page 23: Col-Met 2013 Sales Literature

Model Inside (Ft.-0”) Single Entry Outside Double Entry Outside Recirculating Fan Exhaust Fan Burner Gas

Number W H D W H D W H D SCFM HP SCFM HP BTU HP AREA Train

BO-05-06-05-SE 5'-0" 6'-0" 5'-0" 7’-4” 7’-4” 10’-2” 7’-4” 11’-0” 5’-10” 1,500 1.5 500 1 500 0.33 150 1” NPTBO-05-06-06-SE 5'-0 " 6'-0" 6'-0" 7’-4” 7’-4” 11’-2” 7’-4” 11’-0” 6’-10” 1,800 1.5 500 1 500 0.33 180 1” NPTBO-05-06-07-SE 5'-0 " 6'-0" 7'-0" 7’-4” 7’-4” 12’-2” 7’-4” 11’-0” 7’-10” 2,100 2 500 1 500 0.33 210 1” NPTBO-05-06-08-SE 5'-0 " 6'-0" 8'-0" 7’-4” 7’-4” 13’-2” 7’-4” 11’-0” 8’-10” 2,400 2 500 1 500 0.33 240 1” NPTBO-05-06-10-SE 5'-0 " 6'-0" 10'-0" 7’-4” 7’-4” 14’-2” 7’-4” 11’-0” 10’-10” 3,000 3 500 1 500 0.33 300 1” NPTBO-05-06-12-SE 5'-0 " 6'-0" 12'-0" 7’-4” 7’-4” 16’-2” 7’-4” 11’-0” 12’-10” 3,600 5 500 1 500 0.33 360 1” NPTBO-06-06-06-SE 6'-0" 6'-0" 6'-0" 8’-4” 7’-4” 11’-2” 8’-4” 11’-0” 6’-10” 2,160 2 500 1 500 0.33 216 1” NPTBO-06-06-08-SE 6'-0" 6'-0" 8'-0" 8’-4” 7’-4” 13’-2” 8’-4” 11’-0” 8’-10” 2,880 3 500 1 500 0.33 288 1” NPTBO-06-06-10-SE 6'-0" 6'-0" 10'-0" 8’-4” 7’-4” 15’-2” 8’-4” 11’-0” 10’-10” 3,600 5 500 1 500 0.33 360 1” NPTBO-06-06-12-SE 6'-0" 6'-0" 12'-0" 8’-4” 7’-4” 17’-2” 8’-4” 11’-0” 12’-10” 4,320 5 500 1 500 0.33 432 1” NPTBO-06-06-14-SE 6'-0" 6'-0" 14'-0" 8’-4” 7’-4” 19’-2” 8’-4” 11’-6” 14’-10” 5,040 5 500 1 500 0.33 504 1” NPTBO-06-06-16-SE 6'-0" 6'-0" 16'-0" 8’-4” 7’-4” 21’-2” 8’-4” 11’-6” 16’-10” 5,760 5 500 1 1,000 0.33 576 1” NPTBO-06-07-06-SE 6'-0" 7'-0" 6'-0" 8’-4” 8’-4” 11’-2” 8’-4” 12’-0” 6’-10” 2,520 5 500 1 500 0.33 252 1” NPTBO-06-07-08-SE 6'-0" 7'-0" 8'-0" 8’-4” 8’-4” 13’-2” 8’-4” 12’-0” 8’-10” 3,360 5 500 1 500 0.33 336 1” NPTBO-06-07-10-SE 6'-0" 7'-0" 10'-0" 8’-4” 8’-4” 14’-2” 8’-4” 12’-6” 10’-10” 4,200 5 500 1 500 0.33 420 1” NPTBO-06-07-12-SE 6'-0" 7'-0" 12'-0" 8’-4” 8’-4” 16’-2” 8’-4” 12’-6” 12’-10” 5,040 5 500 1 500 0.33 504 1” NPTBO-06-07-14-SE 6'-0" 7'-0" 14'-0" 8’-4” 8’-4” 18’-2” 8’-4” 12’-6” 14’-10” 5,880 5 500 1 1,000 0.33 588 1” NPTBO-06-07-16-SE 6'-0" 7'-0" 16'-0" 8’-4” 9’-4” 20’-4” 8’-4” 12’-6” 16’-10” 6,720 5 500 1 1,000 0.33 672 1” NPTBO-06-08-06-SE 6'-0" 8 '-0" 6'-0" 8’-4” 9’-4” 11’-2” 8’-4” 12’-6” 6’-10” 2,880 3 500 1 500 0.33 288 1” NPTBO-06-08-08-SE 6'-0" 8'-0" 8'-0" 8’-4” 9’-4” 13’-2” 8’-4” 12’-6” 8’-10” 3,840 3 500 1 500 0.33 384 1” NPTBO-06-08-10-SE 6'-0" 8'-0" 10'-0" 8’-4” 9’-4” 15’-2” 8’-4” 13’-6” 10’-10" 4,800 5 500 1 500 0.33 480 1” NPTBO-06-08-12-SE 6'-0" 8'-0" 12'-0" 8’-4” 9’-4” 17’-2” 8’-4” 13’-6” 12’-10” 5,760 5 500 1 500 0.33 576 1” NPTBO-06-08-14-SE 6'-0" 8'-0" 14'-0" 8’-4” 9’-4” 19’-4” 8’-4” 13’-6” 14’-10” 6,720 5 500 1 1,000 0.33 672 1” NPTBO-06-08-16-SE 6'-0" 8 '-0" 16'-0" 8’-4” 9’-4” 21’-4” 8’-4” 13’-6” 16’-10” 7,680 7.5 500 1 1,000 0.33 768 1” NPTBO-07-07-07-SE 7'-0" 7'-0" 7'-0" 9’-4” 8’-4” 12’-8” 8’-4” 12’-0” 7’-10” 3,430 5 500 1 500 0.33 343 1” NPTBO-07-07-08-SE 7'-0" 7'-0" 8'-0" 9’-4” 8’-4” 13’-8” 8’-4” 12’-0” 8’-10” 3,920 3 500 1 500 0.33 392 1” NPTBO-07-07-10-SE 7'-0" 7'-0" 10'-0" 9’-4” 8’-4” 16’-2” 8’-4” 12’-6” 10’-10” 4,900 5 500 1 500 0.33 490 1” NPTBO-07-07-12-SE 7'-0" 7'-0" 12'-0" 9’-4” 8’-4” 18’-2” 8’-4” 12’-6” 12’-10” 5,880 5 500 1 1,000 0.33 588 1” NPTBO-07-07-14-SE 7'-0" 7'-0" 14'-0" 9’-4” 8’-4” 20’-2” 8’-4” 12’-6” 14’-10” 6,860 7.5 500 1 1,000 0.33 686 1” NPTBO-07-07-16-SE 7'-0" 7'-0" 16'-0" 9’-4” 8’-4” 22’-8” 8’-4” 12’-8” 16’-10” 7,840 7.5 750 1 1,000 0.33 784 1” NPTBO-08-08-08-SE 8'-0" 8'-0" 8'-0" 10’-10” 9’-4” 14’-8” 10’-10” 13’-10” 8’-10” 5,120 5 500 1 500 0.33 512 1” NPTBO-08-08-10-SE 8'-0" 8'-0" 10'-0" 10’-10” 9’-4” 16’-8” 10’-10” 13’-10” 10’-10” 6,400 5 500 1 1,000 0.33 640 1” NPTBO-08-08-12-SE 8'-0" 8'-0" 12'-0" 10’-10” 9’-4” 18’-10” 10’-10” 14’-0” 12’-10” 7,680 7.5 500 1 1,000 0.33 768 1” NPTBO-08-08-14-SE 8'-0" 8'-0" 14'-0" 10’-10” 9’-4” 20’-10” 10’-10” 14’-0” 14’-10” 8,960 7.5 750 1 1,000 0.33 896 1” NPTBO-08-08-16-SE 8'-0" 8 '-0" 16'-0" 10’-10” 9’-4” 21’-10” 10’-10” 14’-0” 16’-10” 10,240 10 1,000 1 1,000 0.33 1,024 1” NPTBO-08-08-20-SE 8'-0" 8'-0" 20'-0" 10’-10” 9’-4” 27’-8” 10’-10” 14’-6” 20’-10” 12,800 10 1,350 1 1,500 0.33 1,280 1.5” NPTBO-08-10-08-SE 8'-0" 10'-0" 8'-0" 10’-10” 11’-4” 14’-4” 10’-10” 15’-10” 8’-10” 6,400 5 500 1 1,000 0.33 640 1” NPTBO-08-10-10-SE 8'-0" 10'-0" 10'-0" 10’-10” 11’-4” 16’-4” 10’-10” 15’-10” 10’-10” 8,000 7.5 750 1 1,000 0.33 800 1” NPTBO-08-10-12-SE 8'-0" 10'-0" 12'-0" 10’-10” 11’-4” 18’-4” 10’-10” 15’-10” 12’-10” 9,600 10 1,000 1 1,000 0.33 960 1” NPTBO-08-10-14-SE 8'-0" 10'-0" 14'-0" 10’-10” 11’-4” 16’-4” 10’-10” 16’-0” 14’-10” 11,200 10 1,000 1 1,500 0.33 1,120 1.5” NPTBO-08-10-16-SE 8'-0" 10'-0" 16'-0" 10’-10” 11’-4” 18’-10” 10’-10” 17’-2” 16’-10” 12,800 10 1,000 1 1,500 0.33 1,280 1.5” NPTBO-10-10-10-SE 10'-0" 10'-0" 10'-0" 12’-10” 11’-4” 17’-0” 10’-10” 17’-2” 10’-10” 10,000 10 1,000 1 1,000 0.33 1,000 1” NPTBO-10-10-12-SE 10'-0" 10 -0" 12'-0" 12’-10” 11’-4” 19’-6” 10’-10” 17’-2” 12’-10” 12,000 10 1,000 1 1,500 0.33 1,200 1.5” NPTBO-10-10-14-SE 10'-0" 10-0" 14'-0" 12’-10” 11’-4” 21’-6” 10’-10” 17’-2” 14’-10” 14,000 10 1,350 1 1,500 0.33 1,400 1.5” NPT

Alternative Configurations: Double Entry (DE)

500° POWDER CURE BATCH OVEN

Industrial Powder

Page 24: Col-Met 2013 Sales Literature

BATCH POWDER BOOTH

Industrial

The Batch Powder Booth makes efficient use of shop space and is designed for batch powder coating with no provisions for powder reclamation.Air is drawn in through the open front of the spray booth, passes through the booth’s working area into the filtered exhaust plenum. The air is filtered in three stages and discharged back into the room. One set of filters will be provided with each booth.

electric components can be purchased separately

OVERVIEW

POWDER EXHAUST FILTER PROVING ASSEMBLY

are precision punched for easy nut and bolt assembly

Powder

Page 25: Col-Met 2013 Sales Literature

BATCH POWDER BOOTH

Interior Dimensions Exterior Dimensions Total Fan Specs. Lights

Width Height Length Width Height Length CFM Qty. Dia. HP S&G

4'-0" 7'-0" 5'-0" 4'-4" 12'-0" 8'-4" 2,800 1 18" 1.5 1 6'-0" 7’-0" 5'-0" 6'-4" 12'-0" 8'-6" 4,200 1 24" 2 1 8'-0" 7'-0" 5'-0" 8'-4" 12'-0" 8'-6" 5,600 1 24" 3 1 10'-0" 7'-0" 5'-0" 10'-4" 12'-0" 9'-0" 7,000 1 30" 3 2 12'-0" 7'-0" 7'-0" 12'-4" 13'-0" 11'-0" 8,400 1 30" 5 2 14'-0" 7'-0" 7'-0" 15'-0" 13'-0" 11'-2" 9,800 1 30" 5 2 16'-0" 7'-0" 7'-0" 17'-0" 12'-0" 10'-8" 11,200 2 (5600CFM) 24" 3 2 4'-0" 8'-0" 5'-0" 4'-4" 13'-0" 8'-4" 3,200 1 18" 2 1 6'-0" 8'-0" 5'-0" 6'-4" 13'-0" 8'-6" 4,800 1 24" 2 1 8'-0" 8'-0" 5'-0" 8'-4" 13'-0" 8'-6" 6,400 1 24" 3 1 10'-0" 8'-0" 5'-0" 10'-2" 14'-0" 9'-0" 8,000 1 30" 5 2 12'-0" 8'-0" 7'-0" 12'-4" 14'-0" 11'-0" 9,600 1 30" 5 2 14'-0" 8'-0" 7'-0" 15'-0" 13'-0" 10'-8" 11,200 2 (5600CFM) 24" 3 2 16'-0" 8'-0" 7'-0" 17'-0" 13'-0" 10'-8" 12,800 2 (6400CFM) 24" 3 2 4'-0" 10'-0" 5'-0" 4'-4" 15'-0" 8'-6" 4,000 1 24" 2 1 6'-0" 10'-0" 5'-0" 6'-4" 15'-0" 8'-6" 6,000 1 24" 3 1 8'-0" 10'-0" 5'-0" 8'-4" 16'-0" 9'-8" 8,000 1 30" 5 1 10'-0" 10'-0" 5'-0" 10'-4" 15'-0" 8'-6" 10,000 2 (5000CFM) 24" 3 2 12'-8" 10'-0" 7'-0" 12'-4" 15'-0" 10'-6" 12,000 2 (6000CFM) 24" 3 2 14'-0" 10'-0" 7'-0" 15'-0" 15'-0" 11'-2" 14,000 2 (7000CFM) 30" 3 2 16'-0" 10'-0" 7'-0" 17'-0" 16'-0" 11'-2" 16,000 2 (8000CFM) 30" 5 2

Reference Key A B C D E F

PB-04-07-05PB-06-07-05PB-08-07-05PB-10-07-05PB-12-07-07PB-14-07-07PB-16-07-07PB-04-08-05PB-06-08-05PB-08-08-05PB-10-08-07PB-12-08-07PB-14-08-07PB-16-08-07PB-04-10-05PB-06-10-05PB-08-10-05PB-10-10-05PB-12-10-07PB-14-10-07PB-16-10-07

ModelNumber

Industrial Powder

Page 26: Col-Met 2013 Sales Literature

CARTRIDGE BATCH POWDER BOOTHWITH NON-ROLLAWAY CASTER BASE

Industrial

PANELSPanels are fabricated from 18-gauge prime quality galvanized steel, flanged and precision punched on 6 centers for maximum rigidity. Panels are fastened together with 5/16 inch bolts with self locking nuts and are to be sealed with the provided caulk following assembly.ILLUMINATIONLighting is provided by Class I Division II, 48 long, fluorescent, 32-watt, T-8 type fixtures (four-tube), mounted behind safety glass; appropriately sealed from the interior of the spray booth. All fixtures are UL listed and approved for their intended use and placement.PURGE CONTROL This feature assures the safe operation of the coatings enclosure, by maintaining the airflow at design levels. During operation overspray powder accumulates on the cartridgefilters. As the cartridge filters load, airflow decreases and negative pressure rises within the air handler. A timer activates a system of air purging valves that clear the cartridge filters of accumulated powder to ensure maximum filter life.CONTROL EQUIPMENT

COLLECTOR MODULE

POWDER COLLECTOR STYLE BOOTH

CARTRIDGE COLLECTOR

Powder

Page 27: Col-Met 2013 Sales Literature

CARTRIDGE COLLECTORS

POWDER BOOTHS

Model

Interior Dimensions Exterior Dimensions Total Modules Cartridge Final Fan Spec. Lights Number Width Height Length Width Height Length CFM Modules Filters Filters Qty. HP S & G

RPC-4000 N/A N/A N/A 4’-8” (w/CP 5’-10”) 8’-8” (w/MFD 9’-4”) 4’-4” (w/ Motor 6’-1”) 4000 @3” SP 1 4 4 1 5 HP N/A

RPC-5000 N/A N/A N/A 4’-8” (w/CP 5’-10”) 8’-8” (w/MFD 9’-4”) 4’-4” (w/ Motor 6’-1”) 5000 @3” SP 1 5 4 1 7.5 HP N/A

RPC-6000 N/A N/A N/A 6’-0” (w/CP 7’-2”) 8’-8” (w/MFD 9’-4”) 5’-3” (w/ Motor 6’-2”) 6000 @3” SP 1 6 6 1 7.5 HP N/A

RPC-7000 N/A N/A N/A 6’-0” (w/CP 7’-2”) 8’-8” (w/MFD 9’-4”) 5’-3” (w/ Motor 6’-2”) 7000 @3” SP 1 7 6 1 10 HP N/A

RPC-8000 N/A N/A N/A 6’-0” (w/CP 7’-2”) 8’-8” (w/MFD 9’-4”) 5’-3” (w/ Motor 6’-2”) 8000 @3” SP 1 7 6 1 10 HP N/A

Model Interior Dimensions Exterior Dimensions Total Modules Cartridge Final Fan Spec. Lights Number Width Height Length Width Height Length CFM Filters Filters Qty. HP S & G

RPB -08-07-7.5 7’-0” 8’-0” 7’-6” 8’-4” 9’-4” 13’-8” 6000 @3” SP 1 (6,000 CFM) 6 6 1 7.5 HP 1

RPB-08-08-7.5 8’-0” 8’-0” 7’-6” 8’-4” 9’-4” 13’-8” 6000 @3” SP 1 (6,000 CFM) 6 6 1 7.5 HP 1

RPB-08-10-7.5 8’-0” 10’-0” 7’-6” 8’-4” 10’-2” 13’-8” 8000 @3” SP 1 (8,000 CFM) 7 6 1 10 HP 1

RPB-10-07-7.5 10’-0” 7’-0” 7’-6” 10’-4” 9’-4” 13’-8” 7000 @3” SP 1 (7,000 CFM) 7 6 1 10 HP 2

RPB-10-08-7.5A 10’-0” 8’-0” 7’-6” 10’-4” 9’-4” 13’-8” 8000 @3” SP 1 (8,000 CFM) 7 6 1 10 HP 2

RPB-10-08-7.5B 10’-0” 8’-0” 7’-6” 10’-4” 9’-4” 13’-7” 8000 @3” SP 2 (4,000 CFM) 7 8 2 5 HP 2

RPB-10-10-7.5 10’-0” 10’-0” 7’-6” 10’-4” 10’-2” 13’-7” 10000 @3” SP 2 (5,000 CFM) 9 8 2 7.5 HP 2

RPB-12-07-7.5A 12’-0” 7’-0” 7’-6” 12’-4” 9’-4” 13’-8” 8000 @3” SP 1 (8,000 CFM) 7 6 1 10 HP 2

RPB-12-07-7.5B 12’-0” 7’-0” 7’-6” 12’-4” 9’-4” 13’-7” 8000 @3” SP 2 (4,000 CFM) 7 8 2 5 HP 2

RPB-12-08-7.5 12’-0” 8’-0” 7’-6” 12’-4” 9’-4” 13’-7” 10000 @3” SP 2 (5,000 CFM) 9 8 2 7.5 HP 2

RPB-12-10-7.5 12’-0” 10’-0” 7’-6” 12’-4” 10’-2” 13’-7” 12000 @3” SP 2 (6,000 CFM) 9 12 2 7.5 HP 2

Reference Key A B C D E F

CARTRIDGE BATCH POWDER BOOTHWITH NON-ROLLAWAY CASTER BASE

Industrial Powder

Page 28: Col-Met 2013 Sales Literature

EZ PASS THRU POWDER BOOTH

Parts enter the booth through the conveyor openings, then pass the coating operator stations to receive the coating. The powder overspray is entrained within the air stream moving to the collector module, where the cartridge filters will remove the particulate. The containment air is drawn through the air handler’s primary and final filter system before being discharged back into the room. Coated parts exit the booth for conveyance to the cure oven. CONTROL EQUIPMENT

ILLUMINATION " long, fluorescent, listed and approved for their intended use and placement.

™ roof panels may be substituted for the light fixtures. PURGE CONTROLThis feature assures the safe operation of the coatings enclosure, powder accumulates on the cartridge filters. The term for this is valves that clear the cartridge filters of accumulated powder as needed.SAFETY EQUIPMENT

CONSTRUCTION FEATURES AND QUALITY STANDARDSBooths

SHOWN WITH STAINLESS STEEL OPTION & LEXAN ROOF OPTION

POWDER BOOTH WITH COLLECTOR MODULE

Industrial Powder

Page 29: Col-Met 2013 Sales Literature

COLLECTOR MODULE

filter section does not have to be cleaned between color change outs.™" " long

™ " " "

AVAILABLE OPTIONS

four regulator air manifolds

Reference Key A B C D E

Model Cabin Dimensions I.D. Part Opening Operator Access Total

Number Width Height Length Width Height Auto Manual CFM

EPB-05-08-14 5’-0” 8’-0” 14’-0” 3’-0” 6’-0” 2 2 7,000 @ 4.5” SP

EPB-06-08-14 6’-0” 8’-0” 14’-0” 4’-0” 6’-0” 2 2 8,000 @ 4.5” SP

EPB-07-08-14 7’-0” 8’-0” 14’-0” 5’-0” 6’-0” 2 2 9,000 @ 4.5” SP

EZ PASS THRU POWDER BOOTH

Industrial Powder

Page 30: Col-Met 2013 Sales Literature

LAB POWDER BOOTH

PANELS Panels are fabricated from18-gauge prime quality stainless steel, flanged and precision punched on 6 centers for maximum rigidity. Panels are fastened together with 5/16 nuts and bolts, and are to be sealed with the pro-vided caulk following assembly.BASE ASSEMBLYThe rollaway base assembly cabinet and floor support is fabricated with 3 channel steel and formed 10-gauge mild steel (welded construc-tion). The finish will be white powder coating.

friendlywork area

LAB POWDER BOOTHWITH ROLLAWAY CASTER BASE

ILLUMINATION long, fluorescent, 32-watt, T-8 type, four-tube fixture, mounted behind safety glass; appropriately sealed for their intended use and placement. PLC BASED PURGE CONTROLThis feature assures the safe operation of the coatings enclosure,

activates a system of air purging valves that clear the cartridge filters of accumulated powder to ensure maximum life.

CONSTRUCTION FEATURES / ADVANTAGES CONTROL EQUIPMENT

OPTIONAL EQUIPMENT

Industrial Powder

Page 31: Col-Met 2013 Sales Literature

LAB POWDER BOOTH

Industrial Powder

Page 32: Col-Met 2013 Sales Literature

LIGHT DUTY CROSSDRAFT

OVERVIEW

LIGHTING FEATURES

Industrial Truck Wood

Page 33: Col-Met 2013 Sales Literature

Model Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Fan Spec. FiltersNumber Width Height Length Doors Width Height Qty Type S&G Open Total SCFM Dia. HP Int. Exh

LDC-16-16-26-N-SB 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 14 15 25,600 42 7.5 48 48

LDC-16-16-28-N-SB 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 14 15 25,600 42 7.5 48 48

LDC-16-16-30-N-SB 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 17 18 25,600 42 7.5 48 48

LDC-16-16-32-N-SB 16'-0" 16'-0" 32'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 17 18 25,600 42 7.5 48 48

LDC-16-16-34-N-SB 16'-0" 16'-0" 34'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 19 20 25,600 42 7.5 48 48

LDC-16-16-44-N-SB 16'-0" 16'-0" 44'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Filtered 2 26 28 25,600 42 7.5 48 48

LDC-16-16-54-N-SB 16'-0" 16'-0" 54'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Filtered 3 31 34 25,600 42 7.5 48 48

LDC-16-16-64-N-SB 16'-0" 16'-0" 64'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Filtered 4 38 42 25,600 42 7.5 48 48

Sizing Option Ranges: 14-20* 12-20* ^

Reference Key A B C D E

Alternative Configurations: Reverse Flow (RF) Drive Through (DT)Alternative Options: Pressurized (P)*Standard Sizing of Width and Height are in Increaments of 2(ft)^Standard Length Sizing is Illustrated above

LIGHT DUTY CROSSDRAFT

Industrial Truck Wood

Page 34: Col-Met 2013 Sales Literature

LIGHT DUTY MODIFIED DOWNDRAFT

OVERVIEW

LIGHTING FEATURES

Industrial Truck Wood

Page 35: Col-Met 2013 Sales Literature

Model Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Fan Spec. FiltersNumber Width Height Length Doors Width Height Qty Type S&G Open Total SCFM Dia. HP Int. Exh

LDM-16-16-26-N-SB 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 25,600 42 7.5 42 48

LDM-16-16-28-N-SB 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 25,600 42 7.5 42 48

LDM-16-16-30-N-SB 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 25,600 42 7.5 42 48

LDM-16-16-32-N-SB 16'-0" 16'-0" 32'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 25,600 42 7.5 42 48

LDM-16-16-34-N-SB 16'-0" 16'-0" 34'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 19 20 25,600 42 7.5 42 48

LDM-16-16-44-N-SB 16'-0" 16'-0" 44'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Solid 2 26 28 25,600 42 7.5 42 48

LDM-16-16-54-N-SB 16'-0" 16'-0" 54'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Solid 3 31 34 25,600 42 7.5 42 48

LDM-16-16-64-N-SB 16'-0" 16'-0" 64'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Solid 4 38 42 25,600 42 7.5 42 48

Sizing Option Ranges: 14-20* 12-20* ^

Reference Key A B C D E

Alternative Configurations: Reverse Flow (RF) Drive Through (DT)Alternative Options: Pre-Filtered (PF) Pressurized (P)*Standard Sizing of Width and Height are in Increaments of 2(ft)^Standard Length Sizing is Illustrated above

LIGHT DUTY MODIFIED DOWNDRAFT

Industrial Truck Wood

Page 36: Col-Met 2013 Sales Literature

LIGHT DUTY SIDE DOWNDRAFT

OVERVIEWThe Light Duty Side Downdraft Booth intakes fresh air from the cleaner upper levels of the shop through a filtered booth ceiling.The filtered air is drawn down and away from the product through exhaust filters at the floor level, along both sides. This provides efficient overspray control that reduces prep time and also provides a much healthier workplace environment without an expensive downdraft exhaust pit. This booth can also be purchased with a pre-filtered plenum or with a pressurized intake plenum. The booth can also be equipped with an air replacement unit and cure cycle to meet your requirements. The Light Duty Side Downdraft Booth is available in either drive-through or solid back configurations.LIGHTING FEATURESBright, full booth illumination is provided by four-tube, 48", 32-watt, fluorescent light fixtures in the angled ceiling panels and side walls. All fixtures are UL listed and approved for their intended use and placement.

10 gauge, galvanized steelAll panels and support members are precision punched for easy nut and bolt assembly5/16” bolt with self locking nuts for fastening panels every 6"fans and ODP motors

doors are pre-hung in a heavy gauge galvanized steel frame for easy installation.slotted hinges to facilitate

other electric components can be purchased separatelyPanel with VFD

Industrial Truck Wood

Page 37: Col-Met 2013 Sales Literature

Model Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Fan Spec. FiltersNumber Width Height Length Doors Width Height Qty Type S&G Open Total SCFM Dia. HP Int. Exh

LDS-16-16-26-N-SB 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 20,800 (2)30 (2)3 38 30

LDS-16-16-28-N-SB 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 22,400 (2)30 (2)5 40 32

LDS-16-16-30-N-SB 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 24,000 (2)30 (2)5 44 36

LDS-16-16-40-N-SB 16'-0" 16'-0" 40'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Solid 2 22 24 32,000 (4)24 (4)3 58 46

LDS-16-16-50-N-SB 16'-0" 16'-0" 50'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Solid 3 27 30 40,000 (4)30 (4)3 72 58

LDS-16-16-60-N-SB 16'-0" 16'-0" 60'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Solid 4 34 36 48,000 (4)30 (4)5 88 70

Sizing Option Ranges: 14-20* 12-20* ^

Reference Key A B C D E

Alternative Configurations: Drive Through (DT)Alternative Options: Pre-Filtered (PF) Pressurized (P)*Standard Sizing of Width and Height are in Increaments of 2(ft)^Standard Length Sizing is Illustrated above

LIGHT DUTY SIDE DOWNDRAFT

Industrial Truck Wood

Page 38: Col-Met 2013 Sales Literature

LIGHT DUTY DOWNDRAFT

OVERVIEWThe Light Duty Downdraft Booth takes in fresh air from the cleaner upper levels of the shop, through a filtered booth ceiling. The filtered air is drawn down and away from the product through exhaust filters in the pit located in the floor. This provides efficientoverspray control that reduces prep time and also provides a much healthier workplace environment. This booth can be purchased with a pre-filtered plenum or with a pressurized intake plenum. It can also be equipped with an air replacement unit and cure cycle to meet your requirements. The Light Duty Downdraft Booth is available in either drive-through or solid back configurations.LIGHTING FEATURES

10 gauge, galvanized steelAll panels and support members are precision punched for easy nut and bolt assembly5/16” bolt with self locking nuts for fastening panels every 6"fans and motors

doors are pre-hung in a heavy gauge galvanized steel frame for easy installation.on slotted hinges to facilitate

other electric components can be purchased separately

Industrial Truck Wood

Page 39: Col-Met 2013 Sales Literature

Model Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Fan Spec. FiltersNumber Width Height Length Doors Width Height Qty Type S&G Open Total SCFM Dia. HP Int. Exh

LDD-16-16-26-N-SB 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 20,800 42 7.5 38 26

LDD-16-16-28-N-SB 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 22,400 42 10 40 28

LDD-16-16-30-N-SB 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 24,000 42 10 44 30

LDD-16-16-40-N-SB 16'-0" 16'-0" 40'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Solid 2 22 24 32,000 (2)42 (2)7.5 58 40

LDD-16-16-50-N-SB 16'-0" 16'-0" 50'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Solid 3 27 30 40,000 (2)42 (2)7.5 72 50

LDD-16-16-60-N-SB 16'-0" 16'-0" 60'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Solid 4 32 36 48,000 (2)42 (2)10 88 60

Sizing Option Ranges: 14-20* 12-20* ^

Reference Key A B C D E

Alternative Configurations: Drive Through (DT)Alternative Options: Pre-Filtered (PF) Pressurized (P)*Standard Sizing of Width and Height are in Increaments of 2(ft)^Standard Length Sizing is Illustrated above

LIGHT DUTY DOWNDRAFT

Industrial Truck Wood

Page 40: Col-Met 2013 Sales Literature

HEAVY DUTY CROSSDRAFT

OVERVIEW

LIGHTING FEATURES

heavy gauge galvanized steel

Industrial Truck Wood

Page 41: Col-Met 2013 Sales Literature

HEAVY DUTY CROSSDRAFT

Model Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Fan Spec. FiltersNumber Width Height Length Doors Width Height Qty Type S&G Open Total SCFM Dia. HP Int. Exh

HDC-16-16-26-N-SB 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 14 15 25,600 42 7.5 48 48

HDC-16-16-28-N-SB 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 14 15 25,600 42 7.5 48 48

HDC-16-16-30-N-SB 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 17 18 25,600 42 7.5 48 48

HDC-16-16-32-N-SB 16'-0" 16'-0" 32'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 17 18 25,600 42 7.5 48 48

HDC-16-16-34-N-SB 16'-0" 16'-0" 34'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 19 20 25,600 42 7.5 48 48

HDC-16-16-44-N-SB 16'-0" 16'-0" 44'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Filtered 2 26 28 25,600 42 7.5 48 48

HDC-16-16-54-N-SB 16'-0" 16'-0" 54'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Filtered 3 31 34 25,600 42 7.5 48 48

HDC-16-16-64-N-SB 16'-0" 16'-0" 64'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Filtered 4 38 42 25,600 42 7.5 48 48

Sizing Option Ranges: 14-20* 12-20* ^

Reference Key A B C D E

Alternative Configurations: Reverse Flow (RF) Drive Through (DT)Alternative Options: Pressurized (P)*Standard Sizing of Width and Height are in Increaments of 2(ft)^Standard Length Sizing is Illustrated above

Industrial Truck Wood

Page 42: Col-Met 2013 Sales Literature

HEAVY DUTY MODIFIED DOWNDRAFT

OVERVIEWThe Heavy Duty Modified Downdraft Booth intakes fresh air from the cleaner upper levels of the shop through a filter bank locatedin the booth ceiling near the product doors. The filtered air is drawn down through the booth to an exhaust filter system at the other end, and is optionally equipped with a pre-filter plenum for additional intake air filtration. The basic modified downdraft design allows for easy pressurization with the addition of an intake plenum with fan or a heated air make up unit.LIGHTING FEATURESBright, full booth illumination is provided by four-tube, 48 , 32-watt, fluorescent light fixtures in the angled ceiling panels andside walls. All fixtures are UL listed and approved for their intended use and placement.

W6x9 beam steelAll panels and support members are precision punched for easy nut and bolt assembly5/16” bolt with self locking nuts for fastening panels every 6" fans and motors

doors are pre-hung in a heavy gauge galvanized steel frame for easy installation.slotted hinges to facilitate

other electric components can be purchased separatelyPanel with VFD

Industrial Truck Wood

Page 43: Col-Met 2013 Sales Literature

HEAVY DUTY MODIFIED DOWNDRAFT

Model Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Fan Spec. FiltersNumber Width Height Length Doors Width Height Qty Type S&G Open Total SCFM Dia. HP Int. Exh

HDM-16-16-26-N-SB 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 25,600 42 7.5 42 48

HDM-16-16-28-N-SB 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 25,600 42 7.5 42 48

HDM-16-16-30-N-SB 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 25,600 42 7.5 42 48

HDM-16-16-32-N-SB 16'-0" 16'-0" 32'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 25,600 42 7.5 42 48

HDM-16-16-34-N-SB 16'-0" 16'-0" 34'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 19 20 25,600 42 7.5 42 48

HDM-16-16-44-N-SB 16'-0" 16'-0" 44'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Solid 2 26 28 25,600 42 7.5 42 48

HDM-16-16-54-N-SB 16'-0" 16'-0" 54'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Solid 3 31 34 25,600 42 7.5 42 48

HDM-16-16-64-N-SB 16'-0" 16'-0" 64'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Solid 4 38 42 25,600 42 7.5 42 48

Sizing Option Ranges: 14-20* 12-20* ^

Reference Key A B C D E

Alternative Configurations: Reverse Flow (RF) Drive Through (DT)Alternative Options: Pre-Filtered (PF) Pressurized (P)*Standard Sizing of Width and Height are in Increaments of 2(ft)^Standard Length Sizing is Illustrated above

Industrial Truck Wood

Page 44: Col-Met 2013 Sales Literature

HEAVY DUTY SIDE DOWNDRAFT

OVERVIEW The Heavy Duty Side Downdraft Booth intakes fresh air from the cleaner upper levels of the shop through a filtered booth ceiling. The filtered air is drawn down and away from the product through exhaust filters at the floor level, along both sides. This provides efficient overspray control that reduces prep time and also provides a much healthier workplace environment without an expensive downdraft exhaust pit. This booth can also be purchased with a pre-filtered plenum or with a pressurized intake plenum. The booth can also be equipped with an air replacement unit and cure cycle to meet your requirements. The Heavy Duty Side Downdraft Booth is available in either drive-through or solid back configurations.LIGHTING FEATURESBright, full booth illumination is provided by four-tube, 48", 32-watt, fluorescent light fixtures in the angled ceiling panels and side walls. All fixtures are UL listed and approved for their intended use and placement.

W6x9 beam steelAll panels and support members are precision punched for easy nut and bolt assembly5/16” bolt with self locking nuts for fastening panels every 6"fans and motors

doors are pre-hung in a heavy gauge galvanized steel frame for easy installation.on slotted hinges to facilitate

other electric components can be purchased separatelyPanel with VFD

Industrial Truck Wood

Page 45: Col-Met 2013 Sales Literature

HEAVY DUTY SIDE DOWNDRAFT

Model Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Fan Spec. FiltersNumber Width Height Length Doors Width Height Qty Type S&G Open Total SCFM Dia. HP Int. Exh

HDS-16-16-26-N-SB 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 20,800 (2)30 (2)3 38 30

HDS-16-16-28-N-SB 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 22,400 (2)30 (2)5 40 32

HDS-16-16-30-N-SB 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 24,000 (2)30 (2)5 44 36

HDS-16-16-40-N-SB 16'-0" 16'-0" 40'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Solid 2 22 24 32,000 (4)24 (4)3 58 46

HDS-16-16-50-N-SB 16'-0" 16'-0" 50'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Solid 3 27 30 40,000 (4)30 (4)3 72 58

HDS-16-16-60-N-SB 16'-0" 16'-0" 60'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Solid 4 34 36 48,000 (4)30 (4)5 88 70

Sizing Option Ranges: 14-20* 12-20* ^

Reference Key A B C D E

Alternative Configurations: Drive Through (DT)Alternative Options: Pre-Filtered (PF) Pressurized (P)*Standard Sizing of Width and Height are in Increaments of 2(ft)^Standard Length Sizing is Illustrated above

Industrial Truck Wood

Page 46: Col-Met 2013 Sales Literature

HEAVY DUTY DOWNDRAFT

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS

OVERVIEW The Heavy Duty Downdraft Booth takes in fresh air from the cleaner upper levels of the shop, through a filtered booth ceiling. The filtered air is drawn down and away from the product through exhaust filters in the pit located in the floor. This providesefficient overspray control that reduces prep time and also provides a much healthier workplace environment. An optional above ground basement exhaust plenum is available for installation without concrete work.This booth can be purchased with a pre-filtered plenum or with a pressurized intake plenum. It can also be equipped with an air replacement unit and cure cycle to meet your requirements. The Heavy Duty Downdraft Booth is available in either drive-through or solid back configurations.LIGHTING FEATURESBright, full booth illumination is provided by four-tube, 48", 32-watt fluorescent light fixtures in the angled ceiling panels and side walls. All fixtures are UL listed and approved for their intended use and placement.

W6x9 beam steelAll panels and support members are precision punched for easy nut and bolt assembly5/16” bolt with self locking nuts for fastening panels every 6"fans and motorsdoors are pre-hung in a heavy gauge galvanized steel frame for easy installation.slotted hinges to facilitate

other electric components can be purchased separatelyPanel with VFD

Industrial Truck Wood

Page 47: Col-Met 2013 Sales Literature

HEAVY DUTY DOWNDRAFT

Model Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Fan Spec. FiltersNumber Width Height Length Doors Width Height Qty Type S&G Open Total SCFM Dia. HP Int. Exh

HDD-16-16-26-N-SB 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 20,800 42 7.5 38 26

HDD-16-16-28-N-SB 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 22,400 42 10 40 28

HDD-16-16-30-N-SB 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 24,000 42 10 44 30

HDD-16-16-40-N-SB 16'-0" 16'-0" 40'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Solid 2 22 24 32,000 (2)42 (2)7.5 58 40

HDD-16-16-50-N-SB 16'-0" 16'-0" 50'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Solid 3 27 30 40,000 (2)42 (2)7.5 72 50

HDD-16-16-60-N-SB 16'-0" 16'-0" 60'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Solid 4 32 36 48,000 (2)42 (2)10 88 60

Sizing Option Ranges: 14-20* 12-20* ^

Reference Key A B C D E

Alternative Configurations: Drive Through (DT)Alternative Options: Pre-Filtered (PF) Pressurized (P)*Standard Sizing of Width and Height are in Increaments of 2(ft)^Standard Length Sizing is Illustrated above

Industrial Truck Wood

Page 48: Col-Met 2013 Sales Literature
Page 49: Col-Met 2013 Sales Literature
Page 50: Col-Met 2013 Sales Literature

OVEN PANELS

CONSTRUCTION FEATURES AND QUALITY DETAILS

SHIPPING

Page 51: Col-Met 2013 Sales Literature

UL CONTROL PANELS

Shipped pre-wired by Col-Met for easy and accurate hookup. Panel controls the exhaust fan and light operation of the spray booth. Panel includes a NEMA 12 enclosure, main disconnect switch, magnetic motor starter with overload disconnect and operative On/Off switch with fire protection interlock. Control Panels are designed for three (3) phase and single (1) phase operations. Consult your factory representative for further information. Not recommended for Col-Met Spray Booths featuring air make-up units, air balancing systems and / or infrared heaters.

OPTIONS / CUSTOM PANELS

All control panels fabricated by Col-Met

M PANELS

Page 52: Col-Met 2013 Sales Literature

TUBEAXIAL BELT DRIVEN FAN

PERFORMANCESIZEAPPLICATIONSFEATURES

Fan Motor SCFM Motor Fan dBA Diameter HP @1/2" SP RPM RPM @5'

12" 3/4 1450 1725 2457 85 18" 3/4-1-1/2 1030-5000 1725 1245-2460 80-90 24" 1-3 5350-9050 1725-1750 1330-1960 88-96 30" 2-5 8850-15000 1750 1035-1500 84-92 36" 5 15296-18392 1750 860-979 87-89 42" 5-10 20263-32457 1750 830-1156 89-98

AERODYNAMIC BELT TUBEWITH STANDARD ACCESS DOOR MAINTENANCE-FREEBEARING ASSEMBLY

Fan Specifications *dBA subject to change depending on actual application