column for capillary electrophoresis cosmo(+)capillary

2
Column for Capillary Electrophoresis COSMO (+) Capillary COSMO(+)Capillary is cationic polymer coated capillary column. Electroosmotic flow (EOF) is from the cathode (-) to the direction of the anode (+) because of the cationic polymer coating inside of the capillary column. - Opposite EOF direction to non-coated capillary - High reproducibility - Applicable over wide pH range (pH 2-10) Comparison of COSMO(+)Capillary and Non-coated Capillary Electropherograms for E.coli Metabolic Extraction The figure shows the analysis data of various kinds of metabolites. COSMO(+)Capillary can analyze them within 20 minutes by electroosmotic flow (EOF) reversal and a sheath liquid consisting of 50 mM ammonium acetate, pH8.5. COSMO(+)Capillary (Cation polymer chemical bonded) Untreated capillary (Fused silica) 1 layer Experimental Conditions: Peak Identification: Data courtesy of Prof. Tomoyoshi Soga, Institute for Advanced Biosciences (IAB), Keio University E.coli W3110, 10 9 Cells COSMO(+) 50 μm I.D. × 110 cm 50 mM Ammonium Acetate, pH8.5 -30 kV 30 sec at 50 mbar 20 o C 10 μl/min 5 mM Ammonium Acetate in 50% (v/v) Methanol - Water Sample: Capillary: Electrolyte: Applied Potential: Injection: Temperature: Sheath liquid: 1: Glycolate 2: Lactate 3: Fumarate 4: 2-Oxoisopentanoate 5: Succinate 6: Malate 7: PEP 8: DHAP 9: Glycerol-3P 10: 3-PG 11: MES (I.S.) 12: Gluconate 13: Ribulose-5P 14: G-1P 15: G-6P+F-6P 16: 2,3-DPG 17: Sedoheptulose-7P 18, F-1,6DP

Upload: others

Post on 03-Nov-2021

33 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Column for Capillary Electrophoresis COSMO(+)Capillary

Column for Capillary Electrophoresis

COSMO(+)Capillary

COSMO(+)Capillary is cationic polymer coated capillary column. Electroosmotic flow (EOF) is from the cathode (-)to the direction of the anode (+) because of the cationic polymer coating inside of the capillary column.

- Opposite EOF direction to non-coated capillary

- High reproducibility

- Applicable over wide pH range (pH 2-10)

Comparison of COSMO(+)Capillary and Non-coated Capillary

Electropherograms for E.coli Metabolic Extraction

The figure shows the analysis data of various kinds of metabolites. COSMO(+)Capillary can analyze them within 20 minutes by electroosmotic flow (EOF) reversal and a sheath liquid consisting of 50 mM ammonium acetate, pH8.5.

COSMO(+)Capillary (Cation polymer chemical bonded)

Untreated capillary (Fused silica)

1 layer

Experimental Conditions:

Peak Identification:

Data courtesy of Prof. Tomoyoshi Soga, Institute for Advanced Biosciences (IAB), Keio University

E.coli W3110, 109 CellsCOSMO(+) 50 μm I.D. × 110 cm50 mM Ammonium Acetate, pH8.5-30 kV30 sec at 50 mbar20oC10 μl/min 5 mM Ammonium Acetatein 50% (v/v) Methanol - Water

Sample:Capillary:Electrolyte:Applied Potential:Injection:Temperature:Sheath liquid:

1: Glycolate2: Lactate3: Fumarate4: 2-Oxoisopentanoate 5: Succinate6: Malate7: PEP8: DHAP9: Glycerol-3P

10: 3-PG11: MES (I.S.) 12: Gluconate13: Ribulose-5P14: G-1P15: G-6P+F-6P16: 2,3-DPG17: Sedoheptulose-7P18, F-1,6DP

Page 2: Column for Capillary Electrophoresis COSMO(+)Capillary

Application Data

1106

For research use only, not intended for diagnostic or drug use.

NACALAI TESQUE, INC.Nijo Karasuma, Nakagyo-ku, Kyoto 604-0855 JAPANTELFAXWebsiteE-mail

: +81-(0)75-251-1730: +81-(0)75-251-1763: www.nacalai.com: [email protected]

Ordering Information

Reproducibility of Reference Standards

The Number of Experiments

Experimental Conditions:

Sample Concentration 50 μmol/l eachCapillary COSMO(+) 50 μm I.D. × 110 cmElectrolyte 50 mM Ammonium Acetate, pH8.5Applied Potential -30 kVInjection 30 sec at 50 mbarTemperature 20CSheath liquid 10 μl/min 5 mM Ammonium Acetate

in 50% (v/v) Methanol - Water

Data courtesy of Prof. Tomoyoshi Soga, Institute for Advanced Biosciences (IAB), Keio University

The figure shows high reproducibility when COSMO(+)Capillary is used repetitively (26 reference standards).

Acid Analysis of Salivary

0

0.5

1

0

1

2

0

2

4

0

5

10

0

0.5

1

Inte

nsity

0

0.5

1

0

1

2

0

2

4

0

5

10

0

0.5

0 10

(x104)4

1

5 15 20Migration Time / min

(a)

(b)

(c)

(d)

(e)

Experimental Conditions:

Capillary COSMO(+) 50 μm I.D. × 110 cmElectrolyte 50 mM ammonium acetate, pH8.5Applied Potential -30 kVInjection -10 kV × 30 secTemperature 25CSheath liquid 10 mM Ammonium Carbonate: 2-Propanol =1:1

(a) Lactic Acid (m/z=89)(b) Succinic Acid (m/z=117)(c) Malic Acid (m/z=133)(d) Uric Acid (m/z=167)(e) Citrate (m/z=191)

Data courtesy of Yoshihide Tanaka, National Institute of Advanced Industrial Science and Technology

The COSMO(+)Capillary enables separation of Succinic Acid which fused silica can not separate.Furthermore it has shorter analysis time for other acids than fused silica.

Product Name Product Number PKG SizeCOSMO(+)Capillary (50 μm I.D. x 120 cm) 07584-44 2 PKG